Çakmak G, Donmez MB, Molinero-Mourelle P, Kahveci Ç, Abou-Ayash S, Peutzfeldt A, Yilmaz B. Fracture resistance of additively or subtractively manufactured resin-based definitive crowns: Effect of restorative material, resin cement, and cyclic loading. Dent Mater 2024; 40:1072-1077. [PMID: 38777731 DOI: 10.1016/j.dental.2024.05.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 05/15/2024] [Indexed: 05/25/2024]
Abstract
OBJECTIVE To evaluate how restorative material, resin cement, and cyclic loading affect the fracture resistance of resin-based crowns fabricated by using additive or subtractive manufacturing. METHODS A right first molar crown standard tessellation language (STL) file was used to fabricate 120 crowns from one subtractively manufactured polymer-infiltrated ceramic network (SM) and two additively manufactured resin composites (AM-B and AM-S) (N = 40). These crowns were randomly divided into 4 groups within each material according to the dual-polymerizing resin cement to be used (RX and PN) and the aging condition (n = 10). After cementation, the crowns without cyclic loading were subjected to fracture testing, while the others were first cyclically loaded (1.7 Hz, 1.2 million cycles, and 49-N load) and then subjected to fracture testing. Data were analyzed with generalized linear model analysis (α = .05). RESULTS Fracture resistance of the crowns was affected by material, resin cement, and cyclic loading (P ≤ .030). However, none of the interactions significantly affected fracture resistance of tested crowns (P ≥ .140). Among tested materials, SM had the highest fracture resistance, whereas AM-B had the lowest (P ≤ .025). RX led to higher fracture resistance, and cyclic loading decreased the fracture resistance (P ≤ .026). SIGNIFICANCE Tested materials can be considered reliable in terms of fracture resistance in short- or mid-term (5 years of intraoral simulation) when used for single molar crowns with 2 mm occlusal thickness. In the long term, polymer-infiltrated ceramic network crowns cemented with RelyX Universal may provide promising results and be less prone to complications considering higher fracture resistance values obtained.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey.
| | - Pedro Molinero-Mourelle
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Conservative Dentistry and Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, Madrid, Spain
| | | | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Anne Peutzfeldt
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, OH, USA
| |
Collapse
|
2
|
Diken Türksayar AA, Demirel M, Donmez MB, Olcay EO, Eyüboğlu TF, Özcan M. Comparison of wear and fracture resistance of additively and subtractively manufactured screw-retained, implant-supported crowns. J Prosthet Dent 2024; 132:154-164. [PMID: 37479623 DOI: 10.1016/j.prosdent.2023.06.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 06/20/2023] [Accepted: 06/21/2023] [Indexed: 07/23/2023]
Abstract
STATEMENT OF PROBLEM Additively manufactured resins indicated for fixed definitive prostheses have been recently marketed. However, knowledge on their wear and fracture resistance when fabricated as screw-retained, implant-supported crowns and subjected to artificial aging is limited. PURPOSE The purpose of this in vitro study was to evaluate the volume loss, maximum wear depth, and fracture resistance of screw-retained implant-supported crowns after thermomechanical aging when fabricated using additively and subtractively manufactured materials. MATERIAL AND METHODS Two additively manufactured composite resins (Crowntec [CT] and VarseoSmile Crown Plus [VS]) and 2 subtractively manufactured materials (1 reinforced composite resin, Brilliant Crios [BC] and 1 polymer-infiltrated ceramic network, Vita Enamic [EN]) were used to fabricate standardized screw-retained, implant-supported crowns. After fabrication, the crowns were cemented on titanium base abutments and then tightened to implants embedded in acrylic resin. A laser scanner with a triangular displacement sensor (LAS-20) was used to digitize the pre-aging state of the crowns. Then, all crowns were subjected to thermomechanical aging (1.2 million cycles under 50 N) and rescanned. A metrology-grade analysis software program (Geomagic Control X 2020.1) was used to superimpose post-aging scans over pre-aging scans to calculate the volume loss (mm3) and maximum wear depth (mm). Finally, all crowns were subjected to a fracture resistance test. Fracture resistance and volume loss were evaluated by using 1-way analysis of variance and Tukey Honestly significant difference (HSD) tests, whereas the Kruskal-Wallis and Dunn tests were used to analyze maximum wear depth. Chi-squared tests were used to evaluate the Weibull modulus and characteristic strength data (α=.05). RESULTS Material type affected the tested parameters (P<.001). CT and VS had higher volume loss and maximum wear depth than BC and EN (P<.001). EN had the highest fracture resistance among tested materials (P<.001), whereas BC had higher fracture resistance than CT (P=.011). The differences among tested materials were not significant when the Weibull modulus was considered (P=.199); however, VE had the highest characteristic strength (P<.001). CONCLUSIONS Additively manufactured screw-retained, implant-supported crowns had higher volume loss and maximum wear depth. All materials had fracture resistance values higher than the previously reported masticatory forces of the premolar region; however, the higher characteristic strength of the subtractively manufactured polymer-infiltrated ceramic network may indicate its resistance to mechanical complications.
Collapse
Affiliation(s)
- Almira Ada Diken Türksayar
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey; and Guest Researcher, ADMiRE Research Center-Additive Manufacturing, Intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, Villach, Austria
| | - Münir Demirel
- Assistant Professor, Oral and Dental Health, Vocational School, Biruni University, Istanbul, Turkey
| | - Mustafa Borga Donmez
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; and Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Emin Orkun Olcay
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey
| | - Tan Fırat Eyüboğlu
- Associate Professor, Department of Endodontics, Istanbul Medipol University, Faculty of Dentistry, Istanbul, Turkey
| | - Mutlu Özcan
- Professor and Head, Clinic of Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
3
|
Çakmak G, Oosterveen-Rüegsegger AL, Akay C, Schimmel M, Yilmaz B, Donmez MB. Influence of polishing technique and coffee thermal cycling on the surface roughness and color stability of additively and subtractively manufactured resins used for definitive restorations. J Prosthodont 2024; 33:467-474. [PMID: 37421940 DOI: 10.1111/jopr.13730] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 06/05/2023] [Accepted: 06/25/2023] [Indexed: 07/10/2023] Open
Abstract
PURPOSE To evaluate how different polishing techniques and coffee thermal cycling affect the surface roughness and stainability of additively and subtractively manufactured resins used for definitive prostheses. MATERIALS AND METHODS Two additively manufactured composite resins (Crowntec, CT and VarseoSmile Crown Plus, VS) and a subtractively manufactured resin nanoceramic (Cerasmart, CS) were used to fabricate 90 rectangular-shaped specimens (14 × 12 × 1 mm) (n = 30). After baseline surface roughness (Ra) measurements, specimens were divided into three groups based on the polishing technique; conventional polishing with a 2-stage polishing kit (CP) and surface sealant application (Optiglaze, OG or Vita Akzent LC, VA) (n = 10). After polishing, specimens were subjected to 10,000 cycles of coffee thermal cycling. Ra and color coordinate measurements were performed after polishing and after coffee thermal cycling. Color difference (ΔE00) was calculated. Scanning electron microscope images were taken at each time interval. Kruskal-Wallis or 1-way analysis of variance (ANOVA) were used to evaluate Ra of materials within each polishing-time interval pair and different polishing techniques within each material-time interval pair, while Friedman or repeated measures ANOVA were used to evaluate Ra at different time intervals within each material-polishing pair. ΔE00 was assessed with 2-way ANOVA (α = 0.05). RESULTS Other than VA-after polishing (p = 0.055), tested materials had significantly different Ra within each polishing-time interval pair (p ≤ 0.038). When Ra differences among different polishing techniques within each material-time interval pair were considered, CS had differences after coffee thermal cycling, CT had differences before polishing and after coffee thermal cycling, and VS had differences within each time interval (p ≤ 0.038). When Ra differences among different time intervals within each material-polishing pair were considered, significant differences were observed among all pairs (p ≤ 0.016), except for CS-VA (p = 0.695) and VS-VA (p = 0.300). ΔE00 values were affected by material and polishing technique interaction (p = 0.007). CONCLUSIONS Ra of CS was similar to or lower than the Ra of other materials, regardless of the time interval or polishing technique. CP mostly led to lower Ra than other polishing techniques, whereas VA resulted in a high Ra regardless of the material-time interval pair. Polishing reduced the Ra, while coffee thermal cycling was found to have a small effect. Among tested material-polishing pairs, only CS-VA had moderately unacceptable color change when previously reported threshold values were considered.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Alice Lisa Oosterveen-Rüegsegger
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Private Practice, Zahnarzt Praxis Gadzo AG, Interlaken, Switzerland
| | - Canan Akay
- Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskisehir, Turkey
- Translational Medicine Research and Clinical Center, Osmangazi University, Eskisehir, Turkey
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Ohio, USA
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey
| |
Collapse
|
4
|
Çakmak G, Rusa AM, Donmez MB, Akay C, Kahveci Ç, Schimmel M, Yilmaz B. Trueness of crowns fabricated by using additively and subtractively manufactured resin-based CAD-CAM materials. J Prosthet Dent 2024; 131:951-958. [PMID: 36470758 DOI: 10.1016/j.prosdent.2022.10.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 10/31/2022] [Accepted: 10/31/2022] [Indexed: 12/03/2022]
Abstract
STATEMENT OF PROBLEM Advancements in digital dental technologies have enabled the use of different resin-based materials that can be fabricated either additively or subtractively. However, knowledge on the fabrication trueness of these materials is scarce. PURPOSE The purpose of this in vitro study was to investigate the trueness of crowns fabricated by using different resin-based computer-aided design and computer-aided manufacturing (CAD-CAM) materials. MATERIAL AND METHODS A complete crown for a mandibular right first molar with a 30-μm cement space was designed in standard tessellation language (STL) format. This master STL (MC-STL) was used to fabricate 40 complete crowns with 4 different resin-based CAD-CAM materials and either additive (Crowntec [MS]) or subtractive techniques (Brilliant Crios [BC], breCAM.monoCOM [PMMA], and G-CAM [GR]; n=10). All crowns were digitized with an intraoral scanner (CEREC Primescan SW 5.2) to generate their STL files (TC-STLs). MC-STL and TC-STLs were transferred into a 3-dimensional analysis software program (Medit Link v2.4.4), and a trueness (overall, external, occlusal, intaglio occlusal, and marginal) analysis was performed by using the root mean square (RMS) method. The Kruskal-Wallis and Dunn tests were performed to analyze data (α=.05). RESULTS The test groups had significantly different deviations on all surfaces (P≤.001). MS crowns had higher overall (P≤.007) and external surface (P≤.001) deviations than GR and PMMA crowns, while the differences between GR and PMMA crowns were not significant (P≥.441). BC crowns had higher external surface deviations than GR crowns (P=.005), higher occlusal deviations than GR and MS crowns (P≤.007), and higher intaglio occlusal deviations than GR and MS crowns (P≤.009). However, BC crowns had lower marginal deviations than MS and GR crowns (P≤.018). CONCLUSIONS The brand of resin-based CAD-CAM materials affected the trueness of crowns. Additively manufactured crowns (MS) mostly had lower overall and external surface trueness than the other groups. Nevertheless, the deviation values of occlusal, intaglio occlusal, and marginal trueness were generally small; thus, the effect of the tested materials on clinical crown fit may be negligible.
Collapse
Affiliation(s)
- Gülce Çakmak
- Senior Research Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Ana Maria Rusa
- Dissertation Student, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mustafa Borga Donmez
- Asisstant Professor, Department of Prosthodontics, Istinye University, Faculty of Dentistry, İstanbul, Turkey; Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Canan Akay
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskisehir, Turkey; Associate Professor, Translational Medicine Research and Clinical Center, Osmangazi University, Eskisehir, Turkey
| | - Çiğdem Kahveci
- Assistant Professor, Department of Prosthodontics, Giresun University Faculty of Dentistry, Giresun, Turkey
| | - Martin Schimmel
- Chairman, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; External Research Associate, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio
| |
Collapse
|
5
|
Sasany R, Donmez MB, de Paula MS, Kahveci Ç, Ceylan G, Yilmaz B, Çakmak G. Stainability and translucency of potassium aluminum sulfate applied computer-aided design and computer-aided manufacturing materials after coffee thermocycling. J ESTHET RESTOR DENT 2024; 36:477-483. [PMID: 37877244 DOI: 10.1111/jerd.13154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 10/04/2023] [Accepted: 10/09/2023] [Indexed: 10/26/2023]
Abstract
OBJECTIVE The purpose of this in vitro study was to evaluate the effect of potassium aluminum sulfate (alum) application on the stainability and translucency of computer-aided design and computer-aided manufacturing (CAD-CAM) materials after coffee thermocycling (CTC). MATERIALS AND METHODS Disk-shaped specimens (Ø10 × 1 mm; N = 200) were fabricated by using additively (Crowntec [CT] and Varseo Smile Crown Plus [VS]) and subtractively manufactured (Brilliant Crios [RCR], CEREC Block [FC], and Vita Enamic [VE]) CAD-CAM materials and polished. All specimens were randomly divided into two groups as alum applied and control (n = 10). All specimens were then subjected to CTC (10,000 cycles at 5-55°C) and color coordinates were measured at each time interval. Color differences (ΔE00 ) and relative translucency parameters (RTPs) were calculated and the data were statistically analyzed (a = 0.05). RESULTS Among tested time intervals, alum applied specimens had their lowest ΔE00 after alum application (p ≤ 0.006), except for FC (p = 0.177). In addition, alum applied RCR had lower ΔE00 values than its control specimens (p = 0.029). Alum applied specimens had their lowest RTP after CTC (p < 0.001) and alum application decreased the RTP of CT (p = 0.010). CTC reduced the RTP of all materials in control groups (p < 0.001). Alum applied CT had higher RTP than its control specimens (p = 0.049). CONCLUSIONS Alum application's effect on color change varied depending on the material and alum mostly resulted in clinically acceptable changes in translucency. CTC led to unacceptable color and translucency changes based on previously reported threshold values. CLINICAL SIGNIFICANCE Optical properties of CAD-CAM materials and the sustainability of these properties over time is critical for longevity. Alum may improve the color stability of reinforced composite resin when subjected to long-term coffee consumption.
Collapse
Affiliation(s)
- Rafat Sasany
- Department of Prosthodontics, Faculty of Dentistry, Biruni University, İstanbul, Turkey
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Marcella Silva de Paula
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prevention and Oral Rehabilitation, Universidade Federal de Goiás (UFG), Goiânia, Brazil
| | | | - Gözlem Ceylan
- Department of Prosthodontics, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio, USA
| | - Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
6
|
Güntekin N, Tunçdemir AR. Comparison of volumetric loss and surface roughness of composite dental restorations obtained by additive and subtractive manufacturing methods. Heliyon 2024; 10:e26269. [PMID: 38390076 PMCID: PMC10882017 DOI: 10.1016/j.heliyon.2024.e26269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 02/05/2024] [Accepted: 02/09/2024] [Indexed: 02/24/2024] Open
Abstract
Statement of problem Permanent crown materials produced with new generation additive manufacturing and traditional subtractive manufacturing materials have not been compared in terms of wear resistance. Purpose This study aims to compare the volumetric loss related to wear and resulting surface roughness after aging in a chewing simulator between resin nano ceramics produced with milling technique and permanent crown materials produced with three dimensional (3D) printing. Materials and methods Three different hybrid composite-ceramic (HCC) (The three materials are GC: Cerasmart, VE: Vita Enamic, and GV: Grandio Voco.) and one 3D printed definitive crown resin (FormLabs Permanent Crown Resin) were investigated before aging (n:8), the surface roughness of all samples was measured with a profilometer, and 1 randomly selected sample from each subgroup was imaged with scanning electron microscope (SEM). 3D scans of each sample were obtained with a desktop scanner. Thermomechanical aging was performed using a chewing simulator. Four hundred thousand cycles were completed under a vertical occlusal force of 49 ± 0.7 N with a thermal cycle of 1.7 Hz 5-55° and with a dwell time of 120 s, mimicking 2 years of aging. The imaging procedures were repeated, and the change in surface roughness was evaluated. 3D images were also overlapped, and the volumetric loss was calculated with the relevant inspector software. The data obtained were analyzed by two-way ANOVA (p < 0.05). Result The results showed significant statistical differences for both parameters (p > 0.05). The highest volumetric loss was found in the GV group while the lowest volumetric loss was in the VE group. The highest surface roughness values were observed in the GV group, while the lowest values belonged to the VE one. Conclusion Of the restorative materials evaluated, the VE group is suitable for long-term restorations, whereas the GV one is suitable for medium-term restorations. It is promising in terms of 3D printing technologies that the 3D material gives comparable results with the GV group. Clinical i̇mplication Additive manufacturing techniques are a successful method that accelerates the manufacturing process. Permanent crown resins are promising alternatives to conventional production.
Collapse
Affiliation(s)
- Neslihan Güntekin
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey
| | - Ali Rıza Tunçdemir
- Department of Prosthodontics, Faculty of Dentistry, Necmettin Erbakan University, Konya, Turkey
| |
Collapse
|
7
|
Çakmak G, Chebaro J, Donmez MB, Yılmaz D, Yoon HI, Kahveci Ç, Schimmel M, Yilmaz B. Influence of intraoral scanner and finish line location on the fabrication trueness and margin quality of additively manufactured laminate veneers fabricated with a completely digital workflow. J Prosthet Dent 2024; 131:313.e1-313.e9. [PMID: 37978007 DOI: 10.1016/j.prosdent.2023.10.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 10/23/2023] [Accepted: 10/23/2023] [Indexed: 11/19/2023]
Abstract
STATEMENT OF PROBLEM Knowledge of the fabrication trueness and margin quality of additively manufactured (AM) laminate veneers (LVs) when different intraoral scanners (IOSs) and finish line locations are used is limited. PURPOSE The purpose of this in vitro study was to evaluate the fabrication trueness and margin quality of AM LVs with different finish line locations digitized by using different IOSs. MATERIAL AND METHODS An LV preparation with a subgingival (sub), equigingival (equi), or supragingival (supra) finish line was performed on 3 identical maxillary right central incisor typodont teeth. Each preparation was digitized by using 2 IOSs, (CEREC Primescan [PS] and TRIOS 3 [TS]), and a reference LV for each finish line-IOS pair (n=6) was designed. A total of 90 LVs were fabricated by using these files and urethane acrylate-based definitive resin (Tera Harz TC-80DP) (n=15). Each LV was then digitized by using PS to evaluate fabrication trueness (overall, external, intaglio, and marginal surfaces). Each LV was also qualitatively evaluated under a stereomicroscope (×60), and the cervical and incisal margin quality was graded. Fabrication trueness and cervical margin quality were evaluated by using 2-way analysis of variance, while Kruskal-Wallis and Mann Whitney-U tests were used to evaluate incisal margin quality (α=.05). RESULTS The interaction between the IOS type and the finish line location affected measured deviations at each surface (P≤.020). PS-sub and TS-supra had higher overall trueness than their counterparts. and the subgingival finish line resulted in the lowest trueness (P≤.005). PS and the subgingival finish line led to the lowest trueness of the external surface (P≤.001). TS-sub had the lowest intaglio surface trueness among the TS subgroups, and PS-sub had higher trueness than TS-sub (P<.001). PS-sub and PS-supra had higher marginal surface trueness than their TS counterparts (P<.001). TS resulted in higher cervical margin quality (P=.001). CONCLUSIONS Regardless of the IOS tested, subgingival finish lines resulted in the lowest trueness. The effect of IOS on the measured deviations varied according to the surface evaluated and finish line location. The cervical margin quality of AM LVs was higher when TS was used.
Collapse
Affiliation(s)
- Gülce Çakmak
- Senior Resarch Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Jad Chebaro
- Predoctoral student, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; and Private Practice, Bellinzona, Switzerland
| | - Mustafa Borga Donmez
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey; and ITI Scholar, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Deniz Yılmaz
- Lecturer, Department of Prosthodontics, Faculty of Dentistry, Alanya Alaaddin Keykubat University, Antalya, Turkey
| | - Hyung-In Yoon
- Associate Professor, Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea; and Adjunct Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Çiğdem Kahveci
- Prosthodontist, Ordu Oral and Dental Health Center, Ordu, Turkey
| | - Martin Schimmel
- Professor and Head, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; and External Research Associate, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; and Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| |
Collapse
|
8
|
Prause E, Malgaj T, Kocjan A, Beuer F, Hey J, Jevnikar P, Schmidt F. Mechanical properties of 3D-printed and milled composite resins for definitive restorations: An in vitro comparison of initial strength and fatigue behavior. J ESTHET RESTOR DENT 2024; 36:391-401. [PMID: 37680013 DOI: 10.1111/jerd.13132] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Revised: 08/06/2023] [Accepted: 08/25/2023] [Indexed: 09/09/2023]
Abstract
OBJECTIVE To evaluate the flexural strength and fatigue behavior of a novel 3D-printed composite resin for definitive restorations. MATERIALS AND METHODS Fifty disc-shaped specimens were manufactured from each of a nanohybrid composite resin (NHC), polymer-infiltrated ceramic network (PICN), and 3D-printed composite resin (3D) with CAD-CAM technology. Biaxial flexural strength (σin ) (n = 30 per group) and biaxial flexural fatigue strength (σff ) (n = 20 per group) were measured using piston-on-three-balls method, employing a staircase approach of 105 cycles. Weibull statistics, relative-strength degradation calculations, and fractography were performed. The results were analyzed with 1-way ANOVA and Games-Howell post hoc test (α = 0.05). RESULTS Significant differences in σin and σff among the groups (p < 0.001) were detected. The NHC group provided the highest mean ± standard deviation σin and σff (237.3 ± 31.6 MPa and 141.3 ± 3.8 MPa), followed by the PICN (140.3 ± 12.9 MPa and 73.5 ± 9.9 MPa) and the 3D (83.6 ± 18.5 MPa and 37.4 ± 23.8 MPa) groups. The 3D group exhibited significantly lower Weibull modulus (m = 4.7) and up to 15% higher relative strength degradation with areas of nonhomogeneous microstructure as possible fracture origins. CONCLUSIONS The 3D-printed composite resin exhibited the lowest mechanical properties, where areas of nonhomogeneous microstructure developed during the mixing procedure served as potential fracture origins. CLINICAL SIGNIFICANCE The clinical indications of the investigated novel 3D-printed composite resin should be limited to long-term provisional restorations. A cautious procedure for mixing the components is crucial before the 3D-printing process, since nonhomogeneous areas developed during the mixing could act as fracture origins.
Collapse
Affiliation(s)
- Elisabeth Prause
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Tine Malgaj
- Department of Prosthodontics, Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Andraž Kocjan
- Department for Nanostructured Materials, Jožef Stefan Institute, Ljubljana, Slovenia
| | - Florian Beuer
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Jeremias Hey
- Department of Prosthodontics, School of Dental Medicine, Martin-Luther-University, Halle, Germany
| | - Peter Jevnikar
- Department of Prosthodontics, Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Franziska Schmidt
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, Berlin, Germany
| |
Collapse
|
9
|
Chung SH, Jiang ES, Lim BS, Kim SH, Chang J. Multi-peak Light-emitting Diode Curing Units and Polymerization of 3D-printed Crown and Bridge Resin. Oper Dent 2024; 49:98-109. [PMID: 38058011 DOI: 10.2341/23-061-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/05/2023] [Indexed: 12/08/2023]
Abstract
PURPOSE This study aimed to evaluate the substitutive and additive efficacy of multi-peak light-emitting diode (LED) curing units for post-curing of a three-dimensional- (3D-) printed crown and bridge resin. METHODS A total of 792 disc- and 180 bar-shaped specimens were printed with a crown and bridge resin (NextDent C&B MFH) and post-cured using two LED curing units (VALO Cordless and Bluephase N G4) in fast and standard modes. Conventional post-curing (LC-3D Print Box, Group PC) was compared with LED-only curing (Groups V1, V2, B1, and B2) and LED-combined curing (Groups PV1, PV2, PB1, and PB2) in terms of microhardness, flexural strength, degree of conversion (DC), and CIE L*a*b* color and translucency parameters. Cytotoxicity of the resin eluates was evaluated using the WST-1 assay. Temperature increases on the resin surface were measured with infrared thermography. Data were statistically analyzed using ANOVA and Kruskal-Wallis tests (α=0.05). RESULTS The microhardness and flexural strength in Groups V1, V2, B1, and DC in all LED-only groups were lower than in other groups (p<0.05). Larger color disparities existed between Group PC and all LED-only groups than between Group PC and the others (p<0.05). There was no significant difference in cytotoxicity among the groups. The temperature increase was lowest in Groups V1 and PV1 during light curing (p<0.05). CONCLUSIONS Post-curing by multi-peak LED curing units was not as effective as the conventional post-curing device. Additional post-curing by LED curing units did not improve the material properties.
Collapse
Affiliation(s)
- S H Chung
- Shin Hye Chung, DDS, MSD, PhD, Department of Dental Biomaterials Science, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - E-S Jiang
- En-Shi Jiang, DDS, MSD, PhD, Department of Stomatology, Yanbian University and Affiliated Hospital of Yanbian University, Yanji China
| | - B-S Lim
- Bum-Soon Lim, PhD, Department of Dental Biomaterials Science, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - S-H Kim
- Seong-Hae Kim, Center for Future Dentistry, Seoul National University, Seoul, Republic of Korea
| | - J Chang
- *Juhea Chang, DDS, MSD, PhD, National Dental Care Center for Persons with Special Needs, Seoul National University Dental Hospital, Seoul, Republic of Korea
| |
Collapse
|
10
|
Al Ahmari NM, Alshehri AH, Gadah TS, Alqahtani JA, Almushafi MA, Al Moaleem MM, Al Hatlan EN, Alqhatani AS, Alabydi SM. Comparison of color changes, fracture strengths, and failure modes of conventional endocrowns and endocrowns with different design modifications. Technol Health Care 2024; 32:2395-2408. [PMID: 38427513 DOI: 10.3233/thc-231175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2024]
Abstract
BACKGROUND Endocrowns (ECs) are alternatives for rebuilding severely damaged teeth and show superior efficacy in molars over premolars. OBJECTIVE The objective of this in vitro study is to evaluate the effects of different preparation designs with short pulp chambers on the mean color change (ΔE), fracture resistance, and failure types of mandibular molar ECs. METHOD A total of 40 extracted mandibular molars were treated endodontically and divided into four groups. Samples in groups 1, 2, 3, and 4 had occlusal preparation depths of 5 mm, 3 mm, 3 mm with ferrule, and 3 mm with boxes, respectively. The samples were immersed in coffee and their ΔE values were measured by using the Commission Internationale de l'Eclairage color system. They were also subjected to a fracture test. Next, all specimens were examined visually under a stereomicroscope to evaluate their failure modes and identify their fracture origins. Data were entered and analyzed by using Statistical Package for Social Sciences. RESULTS Among all groups, group 4 (3 mm + boxes) presented the highest ΔE (4.15) after immersion in coffee. Moreover, ANOVA revealed that the ΔE of group 4 (occlusal preparation depth of 3 mm with boxes) was significantly different (p< 0.05) from that of group 2 (3 mm + ferrule, 3.07). The EC with a 3 mm chamfer and ferrule showed the highest maximum load of 2847.68 ± 693.27 N, whereas that with a 5 mm chamfer finish line had a marginally reduced load at fracture of 2831.52 ± 881.83 N. The EC with a 3 mm chamber and boxes had a slightly increased maximum load of 2700.75 ± 436.40 N, whereas that with the 3 mm chamber had the lowest maximum load at fracture of 2385.97 ± 465.61 N. One-way ANOVA showed that different EC preparation designs had no effect on maximum fracture load (F [3,16] = 0.550, p= 0.6). CONCLUSION The recorded ΔE values of ECs in all groups were equal or marginally higher than the acceptable values. The EC with a 3 mm chamfer and ferrule displayed the highest mean maximum load. The EC with a 5 mm chamfer finish line had a marginally lower maximum load at fracture than other ECs. Failures, such as ceramic fracture, split fracture, and ceramic and tooth splitting above the cemento-enamel junction (CEJ) or vertically were predominant in samples with occlusal preparation depths of 3 mm with ferrule and 5 mm.
Collapse
Affiliation(s)
| | - Abdulkarim H Alshehri
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | - Thrya S Gadah
- College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Jaber A Alqahtani
- Aseer Specialized Dental Center, Ministry of Health, Abha, Saudi Arabia
| | | | - Mohammed M Al Moaleem
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| | | | | | | |
Collapse
|
11
|
Çakmak G, Donmez MB, de Paula MS, Akay C, Fonseca M, Kahveci Ç, Abou-Ayash S, Yilmaz B. Surface roughness, optical properties, and microhardness of additively and subtractively manufactured CAD-CAM materials after brushing and coffee thermal cycling. J Prosthodont 2023. [PMID: 37947220 DOI: 10.1111/jopr.13796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 10/18/2023] [Accepted: 11/09/2023] [Indexed: 11/12/2023] Open
Abstract
PURPOSE To evaluate the surface roughness, optical properties, and microhardness of additively or subtractively manufactured CAD-CAM materials after simulated brushing and coffee thermal cycling. MATERIAL AND METHODS Two additively manufactured resins (Crowntec, CT and VarseoSmile Crown Plus, VS) and 3 subtractively manufactured materials (a reinforced composite (Brilliant Crios, BC), a polymer-infiltrated ceramic network (Enamic, VE), and a feldspathic ceramic (Mark II, VM)) were used to fabricate disk-shaped specimens (Ø10×1-mm) (n = 10). Surface roughness, Vickers microhardness, and color coordinates were measured after polishing, while surface roughness was also measured before polishing. Specimens were then subjected to 25000 cycles of brushing and 10000 cycles of coffee thermal cycling, and measurements were repeated after each time interval. Color difference (ΔE00 ) and relative translucency parameter (RTP) were calculated. Robust analysis of variance test was used to evaluate surface roughness, ΔE00 , and RTP data, while generalized linear model analysis was used for microhardness data (α = 0.05). RESULTS Material type and time interval interaction affected tested parameters (p ≤ 0.002). In addition, material type affected all parameters (p < 0.001) other than surface roughness (p = 0.051), and time interval affected surface roughness and microhardness values (p < 0.001). Tested materials mostly had their highest surface roughness before polishing (p ≤ 0.026); however, there was no clear trend regarding the roughness of materials within different time intervals along with ΔE00 and RTP values within materials or time intervals. VS and CT had the lowest microhardness regardless of the time interval, while the remaining materials were listed as VM, VE, and BC in decreasing order (p < 0.001). Coffee thermal cycling only reduced the microhardness of VM (p < 0.001). CONCLUSIONS Tested additively manufactured resins can be considered more susceptible to simulated brushing and coffee thermal cycling than the other materials, given the fact that their surface roughness and ΔE00 values were higher than previously reported acceptability thresholds and because they had the lowest microhardness after all procedures were complete.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Istinye Univeristy, İstanbul, Turkey
| | - Marcella Silva de Paula
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Prevention and Oral Rehabilitation, Universidade Federal de Goiás, Goiánia, GO, Brazil
| | - Canan Akay
- Department of Prosthodontics, Faculty of Dentistry, Eskisehir Osmangazi Univeristy, Eskisehir, Turkey
- Translational Medicine Research and Clinical Center, Osmangazi University, Eskisehir, Turkey
| | - Manrique Fonseca
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | | | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
12
|
Demirel M, Diken Türksayar AA, Donmez MB. Fabrication trueness and internal fit of hybrid abutment crowns fabricated by using additively and subtractively manufactured resins. J Dent 2023; 136:104621. [PMID: 37453654 DOI: 10.1016/j.jdent.2023.104621] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Revised: 07/11/2023] [Accepted: 07/12/2023] [Indexed: 07/18/2023] Open
Abstract
OBJECTIVES To evaluate the fabrication trueness and internal fit of hybrid abutment crowns fabricated by using additively and subtractively manufactured restorative materials. METHODS A maxillary first premolar crown with a screw access channel was designed onto a digitized master titanium base abutment. This file was used to fabricate 40 crowns additively (Crowntec (CT) and VarseoSmile Crown Plus (VS)) or subtractively (Brilliant Crios (BC) and Vita Enamic (EN)) (n = 10). Crowns were digitized with an intraoral scanner and root mean square method was used to evaluate fabrication trueness. Master abutment and the crowns when seated on the abutment were also digitized with the same intraoral scanner and triple scan method was used to evaluate internal fit. Data were analyzed either with 1-way ANOVA (surface deviations) or Kruskal-Wallis (internal fit) tests (α= 0.05). RESULTS CT had the highest overall, external, and marginal surface deviations (P≤.030), whereas BC had the lowest external (P≤.001) and VS and EN had the lowest marginal surface deviations (P≤.007). BC had the highest intaglio surface deviations (P<.001). BC and EN had higher average gap values CT and VS (P≤.006); however, the differences within additively and subtractively manufactured materials were nonsignificant (P≥.858). CONCLUSIONS One of the tested additively manufactured resins (CT) resulted in mostly lower trueness than that of other materials. However, deviations at the intaglio and marginal surfaces were generally small and the maximum mean difference among test groups when average gap was considered was 17.4 µm. Therefore, clinical fit of hybrid abutment crowns fabricated with tested materials may be similar.
Collapse
Affiliation(s)
- Münir Demirel
- Assistant Professor, Oral and Dental Health, Vocational School, Biruni University, Istanbul, Turkey
| | - Almira Ada Diken Türksayar
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey; Guest Researcher, ADMiRE Research Center-Additive Manufacturing, Intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, Villach, Austria
| | - Mustafa Borga Donmez
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| |
Collapse
|
13
|
Çakmak G, Jutzi D, Donmez MB, Kahveci Ç, de Paula MS, Schimmel M, Yilmaz B. Effect of number of supports and build angle on the fabrication and internal fit accuracy of additively manufactured definitive resin-ceramic hybrid crowns. J Dent 2023; 134:104548. [PMID: 37192693 DOI: 10.1016/j.jdent.2023.104548] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 04/03/2023] [Accepted: 05/12/2023] [Indexed: 05/18/2023] Open
Abstract
OBJECTIVES To evaluate the effect of number of supports and build angle on the fabrication and internal fit accuracy (trueness and precision) of additively manufactured resin-ceramic hybrid crowns. METHODS A mandibular first molar crown was designed and nested on the build platform of a printer either with a 30° angle between the occlusal surface and the build platform (BLS (less support) and BMS (more support)) or its occlusal surface parallel to the build platform (VLS (less support) and VMS (more support)) to fabricate additively manufactured resin-ceramic hybrid crowns (n=14). After fabrication, supports were removed by a blinded operator and all crowns were digitized with an intraoral scanner. Fabrication accuracy (overall, external, intaglio occlusal, occlusal, and marginal) was evaluated by using root mean square (RMS) method, while internal fit was evaluated with triple scan method. RMS, average gap, and precision of these data were analyzed (α= .05). RESULTS VLS had higher overall deviations than BLS and VMS (P≤.039). VMS had higher occlusal deviations than BLS (P=.033). While BMS and BLS had higher marginal deviations than VLS (P≤.006), BMS also had higher values than VMS (P=.012). BLS led to higher precision than VMS (intaglio occlusal and occlusal surfaces) and VLS (occlusal surface) (P≤.008). VLS led to higher precision than BMS (marginal surface) (P=.027). Average gap values were similar (P=.723); however, BLS resulted in higher precision than VLS (P=.018). CONCLUSIONS Considering their high marginal and occlusal surface trueness, and similar internal occlusal deviations and average gaps (trueness), clinical fit of resin-ceramic hybrid crowns fabricated with tested parameters may be similar. Reduced number of supports and angled orientation may lead to higher precision of fit. CLINICAL SIGNIFICANCE Tested resin-ceramic hybrid-printer pair may be used to fabricate crowns with reduced number of supports to maintain occlusal surface integrity without compromising the fabrication accuracy and fit.
Collapse
Affiliation(s)
- Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Dino Jutzi
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Istinye University, Faculty of Dentistry, Istanbul, Turkey; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Çiğdem Kahveci
- Department of Prosthodontics, Giresun University Faculty of Dentistry, Giresun, Turkey
| | - Marcella Silve de Paula
- Universidade Federal de Goiás (UFG), Department of Prevention and Oral Rehabilitation, Goiânia, Brazil
| | - Martin Schimmel
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Ohio, USA
| |
Collapse
|
14
|
Donmez MB, Çakmak G, Yılmaz D, Schimmel M, Abou-Ayash S, Yilmaz B, Peutzfeldt A. Bond strength of additively manufactured composite resins to dentin and titanium when bonded with dual-polymerizing resin cements. J Prosthet Dent 2023:S0022-3913(23)00255-X. [PMID: 37183123 DOI: 10.1016/j.prosdent.2023.04.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 04/06/2023] [Accepted: 04/06/2023] [Indexed: 05/16/2023]
Abstract
STATEMENT OF PROBLEM Additively manufactured composite resins for definitive restorations have been recently introduced. The bond strength between these composite resins and different substrates has not been extensively studied. PURPOSE The purpose of this in vitro study was to measure the shear bond strength (SBS) between additively manufactured composite resins and dentin and titanium substrates and compare those with the SBS between subtractively manufactured polymer-infiltrated ceramic and the same substrates (dentin and titanium), when different dual-polymerizing resin cements were used. MATERIAL AND METHODS One hundred and eighty cylinder-shaped specimens (Ø5×5 mm) were prepared from 3 materials recommended for definitive restorations: an additively manufactured composite resin (Crowntec [CT]); an additively manufactured hybrid composite resin (VarseoSmile Crown Plus [VS]); and a subtractively manufactured polymer-infiltrated ceramic (Enamic [EN]) (n=60). Specimens were randomly divided into six subgroups to be cemented to the two substrates (dentin and titanium; n=30) with 1 of 3 resin cements (RelyX Universal, Panavia V5, and Variolink Esthetic DC) (n=10). The restoration surface to be bonded was treated according to the respective manufacturer's recommendations. Dentin surfaces were treated according to the resin cement (Scotchbond Universal Plus Adhesive for RelyX Universal, Panavia V5 Tooth Primer for Panavia V5, and Adhese Universal for Variolink Esthetic DC), while titanium surfaces were airborne-particle abraded, and only the specimens paired with Panavia V5 were treated with a ceramic primer (Clearfil Ceramic Primer Plus). SBS was measured in a universal testing machine at a crosshead speed of 1 mm/min. Failure modes were analyzed under a microscope at ×12 magnification. Data were analyzed by using 2-way analysis of variance and Tukey honestly significant difference tests (α=.05). RESULTS When SBS to dentin was considered, only restorative material, as a main factor, had a significant effect (P<.001); EN had the highest SBS (P<.001), while the difference in SBS values of CT and VS was not significant (P=.145). As for SBS to titanium, the factors restorative material and resin cement and their interaction had a significant effect (P<.001). Within each resin cement, EN had the highest SBS to titanium (P<.001), and within each restorative material, Variolink resulted in the lowest SBS (P≤.010). Overall, EN and RelyX were associated with the highest SBS to titanium (P≤.013). Mixed failures were predominant in most groups. CONCLUSIONS Regardless of the substrate or the resin cement used, the subtractively manufactured polymer-infiltrated ceramic had higher shear bond strength than the additively manufactured composite resins. The SBS of the additively manufactured composite resins, whether bonded to dentin or titanium, were not significantly different from each other. Regardless of the restorative material, Variolink DC resulted in the lowest SBS for titanium surfaces.
Collapse
Affiliation(s)
- Mustafa Borga Donmez
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey; and Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Gülce Çakmak
- Senior Resarch Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Deniz Yılmaz
- Lecturer, Department of Prosthodontics, Faculty of Dentistry, Alanya Alaaddin Keykubat University, Antalya, Turkey
| | - Martin Schimmel
- Professor and Head, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; and External Research Associate, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Samir Abou-Ayash
- Senior Lecturer and Head of the Section of Digital Implant and Reconstructive Dentistry, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; and Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| | - Anne Peutzfeldt
- Senior Researcher, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; and Affiliate Professor, Department of Odontology, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
15
|
Lankes V, Reymus M, Mayinger F, Coldea A, Liebermann A, Hoffmann M, Stawarczyk B. Three-Dimensional Printed Resin: Impact of Different Cleaning Protocols on Degree of Conversion and Tensile Bond Strength to a Composite Resin Using Various Adhesive Systems. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16093580. [PMID: 37176461 PMCID: PMC10179867 DOI: 10.3390/ma16093580] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 05/03/2023] [Accepted: 05/05/2023] [Indexed: 05/15/2023]
Abstract
The present investigation tested the effect of cleaning methods and adhesives on the tensile bond strength (TBS) of a resin-based composite luted to a temporary 3D printed resin. Substrates (n= 360) were printed using a Rapidshape D20II and cleaned with a butyldiglycol-based solution, isopropanol, or by centrifugation. Specimens were air-abraded with Al2O3 (mean particle size 50 µm) at 0.1 MPa followed by pretreatment (n = 30/subgroup) with: (1) Clearfil Ceramic Primer (CCP); (2) Clearfil Universal Bond (CUB); (3) Scotchbond Universal Plus (SUP) or 4. Visio.link (VL) and luted to PanaviaV5. TBS (n = 15/subgroup) was measured initially (24 h at 37 °C water) or after thermal cycling (10,000×, 5/55 °C). The degree of conversion (DC) for each cleaning method was determined prior and after air-abrasion. Univariate ANOVA followed by post-hoc Scheffé test was computed (p < 0.05). Using Ciba-Geigy tables and chi-square, failure types were analyzed. The DC values were >85% after all cleaning methods, with centrifugation showing the lowest. CCP pretreatment exhibited the lowest TBS values, with predominantly adhesive failures. The combination of CCP and centrifugation increased the TBS values (p < 0.001) compared to the chemical cleaning. CUB, SUP, and VL, regardless of cleaning, can increase the bond strength between the 3D printed resin and the conventional luting resin.
Collapse
Affiliation(s)
- Valerie Lankes
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Marcel Reymus
- Department of Conservative Dentistry and Peridontology, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Felicitas Mayinger
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Andrea Coldea
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Anja Liebermann
- Head of the Department of Prosthetic Dentistry, Faculty of Medicine and University Hospital Cologne, 50931 Cologne, Germany
| | - Moritz Hoffmann
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Bogna Stawarczyk
- Scientific Head Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| |
Collapse
|
16
|
PEEK for Oral Applications: Recent Advances in Mechanical and Adhesive Properties. Polymers (Basel) 2023; 15:polym15020386. [PMID: 36679266 PMCID: PMC9864167 DOI: 10.3390/polym15020386] [Citation(s) in RCA: 25] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 01/06/2023] [Accepted: 01/07/2023] [Indexed: 01/15/2023] Open
Abstract
Polyetheretherketone (PEEK) is a thermoplastic material widely used in engineering applications due to its good biomechanical properties and high temperature stability. Compared to traditional metal and ceramic dental materials, PEEK dental implants exhibit less stress shielding, thus better matching the mechanical properties of bone. As a promising medical material, PEEK can be used as implant abutments, removable and fixed prostheses, and maxillofacial prostheses. It can be blended with materials such as fibers and ceramics to improve its mechanical strength for better clinical dental applications. Compared to conventional pressed and CAD/CAM milling fabrication, 3D-printed PEEK exhibits excellent flexural and tensile strength and parameters such as printing temperature and speed can affect its mechanical properties. However, the bioinert nature of PEEK can make adhesive bonding difficult. The bond strength can be improved by roughening or introducing functional groups on the PEEK surface by sandblasting, acid etching, plasma treatment, laser treatment, and adhesive systems. This paper provides a comprehensive overview of the research progress on the mechanical properties of PEEK for dental applications in the context of specific applications, composites, and their preparation processes. In addition, the research on the adhesive properties of PEEK over the past few years is highlighted. Thus, this review aims to build a conceptual and practical toolkit for the study of the mechanical and adhesive properties of PEEK materials. More importantly, it provides a rationale and a general new basis for the application of PEEK in the dental field.
Collapse
|
17
|
Ellakany P, Fouda SM, Mahrous AA, AlGhamdi MA, Aly NM. Influence of CAD/CAM Milling and 3D-Printing Fabrication Methods on the Mechanical Properties of 3-Unit Interim Fixed Dental Prosthesis after Thermo-Mechanical Aging Process. Polymers (Basel) 2022; 14:polym14194103. [PMID: 36236050 PMCID: PMC9572976 DOI: 10.3390/polym14194103] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 09/16/2022] [Accepted: 09/18/2022] [Indexed: 11/20/2022] Open
Abstract
This study assessed the influence of CAD/CAM milling and 3D-printing fabrication methods on mechanical properties of 3-unit interim fixed dental prosthesis (IFDPs) after thermo-mechanical aging. Forty 3-unit IFDPs were fabricated on a mandibular right second premolar and second molar of a typodont cast. Samples were fabricated from the following materials; auto-polymerized polymethyl methacrylate (conventional resin), CAD/CAM PMMA (milled resin) and two different CAD/CAM 3D-printed composite resins; digital light processing Asiga (DLP AS) and stereolithography NextDent (SLA ND). Mechanical properties were compared between the studied materials using Kruskal−Wallis test, followed by multiple pairwise comparisons using Bonferroni adjusted significance. There was a significant difference in flexural strength and microhardness between the studied materials (p < 0.001), with the highest mean ± SD reported in the milled IFDPs (174.42 ± 3.39, 27.13 ± 0.52), and the lowest in the conventional IFDPs (98.02 ± 6.1, 15.77 ± 0.32). Flexural strengths differed significantly between the conventional IFDPs and all materials except DLP AS. The highest elastic modulus was recorded in the milled group, and the lowest in the SLA ND group (p = 0.02). In conclusion, superior flexural strength, elastic modulus, and hardness were reported for milled IFDPs. SLA ND printed IFDPs showed comparable mechanical properties to milled ones except for the elastic modulus.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
- Correspondence: ; Tel.: +966-547812107
| | - Shaimaa M. Fouda
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Amr A. Mahrous
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Maram A. AlGhamdi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Nourhan M. Aly
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria 21527, Egypt
| |
Collapse
|
18
|
Campos MRD, Oliveira TTD, Botelho AL, Reis ACD. Mechanical, Chemical, and Biological Properties of 3D-Printed Abutments: A Systematic Review. JOURNAL OF ADVANCED ORAL RESEARCH 2022. [DOI: 10.1177/23202068221099772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Aim: A systematic review of the methods of 3D printing and the materials used so far for the manufacture of abutments was performed to evaluate whether their clinical use is indicated through the mechanical, chemical, and biological analyses carried out. Materials and Methods: An electronic search conducted by three independent reviewers was carried out in the PubMed, Web of Science, Cochrane Library, Science Direct, and Lilac databases. The inclusion criterion was researching articles in English that contained as subject the manufacturing of abutments through 3D printing/additive manufacturing. Any meta-analyses, reviews, book chapters, abstracts, letters, conferences papers, and studies without abutments printed were excluded. Results: We found 780 references, which after applying the exclusion criteria resulted in the final inclusion of seven articles for review. The studies had a high heterogeneity, showing different materials and methodologies to manufacture abutments, which makes a comparison between them difficult, and for this reason it was not possible to carry out a meta-analysis with the data found. Conclusions: Even with the limitations found in the present research, it is possible to conclude that printed abutments have adequate mechanical, chemical, and biological properties that can indicate their clinical use. 3D printing presents high accuracy and speed and can produce customized abutments according to each case.
Collapse
Affiliation(s)
- Murilo Rodrigues de Campos
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, Ribeirão Preto, SP, Brazil
| | | | - André Luís Botelho
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, Ribeirão Preto, SP, Brazil
| | - Andréa Cândido dos Reis
- Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, Ribeirão Preto, SP, Brazil
| |
Collapse
|
19
|
Demirci F, Bahce E, Baran MC. Mechanical analysis of three-unit metal-free fixed dental prostheses produced in different materials with CAD/CAM technology. Clin Oral Investig 2022; 26:5969-5978. [DOI: 10.1007/s00784-022-04623-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 07/11/2022] [Indexed: 11/03/2022]
|
20
|
Donmez MB, Okutan Y. Marginal gap and fracture resistance of implant-supported 3D-printed definitive composite crowns: An in vitro study. J Dent 2022; 124:104216. [PMID: 35803388 DOI: 10.1016/j.jdent.2022.104216] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 06/20/2022] [Accepted: 07/04/2022] [Indexed: 12/21/2022] Open
Abstract
OBJECTIVES To compare the marginal gap and fracture resistance of implant-supported 3-dimensional (3D) printed definitive composite crowns with those fabricated by using 3 different millable materials. MATERIAL AND METHODS A prefabricated abutment was digitized by using a laboratory scanner (E4 Lab Scanner) and a complete-coverage maxillary first premolar crown was designed (Dental Designer). Forty crowns were fabricated either by 3D printing (Saremco Print Crowntec, SP) or milling (Brilliant Crios, BC; Vita Enamic, VE; Cerasmart 270, CS) (n = 10). Baseline marginal gap values were evaluated by measuring 60 predetermined points on an abutment (15 points for each side) with a stereomicroscope at ×40 magnification. Marginal gap values were reevaluated after adhesive cementation. Load-to-fracture test was performed by using a universal testing machine. Two-way analysis of variance (ANOVA) was used to evaluate the effect of material type and cementation on marginal gap values. While Tukey HSD tests were used to compare the materials' marginal gap values before and after cementation, the effect of cementation on marginal gap values within each material was analyzed by using paired samples t-tests. Fracture resistance data were analyzed by using 1-way ANOVA (α=0.05). RESULTS Material type and cementation significantly affected marginal gap values (P < .001). Regardless of cementation, SP had the lowest marginal gap values (P < .001), while the differences among milled crowns were nonsignificant (P ≥ .14). Cementation significantly increased the marginal gap values (P < .001). Material type did not affect fracture resistance values (F = 1.589, P = .209). CONCLUSION Implant-supported 3D-printed composite crowns showed higher marginal adaptation compared with the milled crowns before and after cementation. In addition, all crowns endured similar forces before fracture.
Collapse
Affiliation(s)
- Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Yener Okutan
- Department of Prosthodontics, Aydin Adnan Menderes University Faculty of Dentistry, Aydin, Turkey.
| |
Collapse
|
21
|
Bending moment of implants restored with CAD/CAM polymer-based restoration materials with or without a titanium base before and after artificial aging. Dent Mater 2022; 38:e245-e255. [PMID: 35715247 DOI: 10.1016/j.dental.2022.06.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 05/05/2022] [Accepted: 06/05/2022] [Indexed: 11/22/2022]
Abstract
OBJECTIVES To test and compare two types of implant systems restored with four monolithic polymer-based materials with regard to their bending moments (BM) before and after aging. METHODS A total of 192 tissue-level implants (TRI Dental Implants) differing in the presence (TiB, Octa line, n = 96) or absence (NTiB, Matrix line, n = 96) of a titanium base were restored with mandibular right first molar crowns manufactured from composite (CC), polymer-infiltrated ceramic (VE), PMMA (PM) and a 3D printed resin (ND) (n = 24). Half of the specimens (n = 12) were loaded for 1,200,000 cycles (50 N, 1.3 Hz, TC: 5/55 °C, 6000×) and examined for failures. Fracture load was measured according to ISO standard 14801, BM was calculated, and fracture types were examined. Data were analyzed using parametric statistics (p < 0.05). RESULTS No failures were observed after 600,000 cycles. After 1,200,000 cycles, wear traces were recorded in all groups except PM, VE and CC on TiB implants. In group CC on NTiB implants, three specimens were rated zero in BM testing as they showed fracture of the screw. Regarding BM, TiB implants exhibited higher values than NTiB implants with aged CC (p = 0.023), aged PM (p < 0.001), initial PM (p = 0.011) and initial VE (p < 0.001). No differences occurred among the implant types with initial CC, initial ND, aged ND and aged VE. With regard to initial BM values, NTiB implants showed higher values for ND and CC compared with PM and VE (p < 0.001). No differences in initial BM values were found for the tested materials on TiB implants (p > 0.116). When aged, restoration material had no impact on the BM values of NTiB implants (p ≥ 0.233). Aged TiB implants showed higher values in combination with CC than with ND (p = 0.001). PM and VE showed similar values as ND and CC. Artificial aging led to a decrease of BM within PM, CC and ND on NTiB implants and ND on TiB implants. The majority of failures after testing were characterized by crown fractures in two to four pieces. Fractures in more pieces with smaller fragments occurred primarily for ND. SIGNIFICANCE The use of NTiB implants with the polymer-based materials tested can only be recommended for clinical use as interim prostheses. CC seems to show a positive effect on the BM. Clinical research investigating the in vivo behavior is necessary to confirm these findings.
Collapse
|
22
|
Load-to-Failure Resistance and Optical Characteristics of Nano-Lithium Disilicate Ceramic after Different Aging Processes. MATERIALS 2022; 15:ma15114011. [PMID: 35683309 PMCID: PMC9182075 DOI: 10.3390/ma15114011] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 06/02/2022] [Accepted: 06/02/2022] [Indexed: 01/27/2023]
Abstract
The aim of this study was to compare the load-to-failure resistance and optical properties of nano-lithium disilicate (NLD) with lithium disilicate (LDS) and zirconia-reinforced lithium silicate (ZLS) in different aging processes. Thirty crowns were milled from NLD, LDS, and ZLS (n = 10). All crowns were subjected to thermomechanical aging and loaded until catastrophic failure. Ten specimens from each material were prepared in two different thicknesses (0.7 mm and 1.5 mm, n = 5), and color coordinates were measured before and after coffee thermocycling. Color differences (ΔE00) and relative translucency parameter (RTP) were calculated. Data were analyzed by using ANOVA and Bonferroni-corrected t-tests (α = 0.05). ZLS had the highest load-to-failure resistance (p ≤ 0.002), while the difference between LDS and NLD was nonsignificant (p = 0.776). The interaction between material type and thickness affected ΔE00 (p < 0.001). Among the 0.7 mm thick specimens, ZLS had the lowest ΔE00 (p < 0.001). Furthermore, 1.5 mm thick ZLS had lower ΔE00 than that of 1.5 mm thick LDS (p = 0.036). Other than ZLS (p = 0.078), 0.7 mm thick specimens had higher ΔE00 (p < 0.001). The interaction between material type, thickness, and thermocycling affected RTP (p < 0.001). Thinner specimens presented higher RTP (p < 0.001). NLD and LDS had higher RTP than ZLS (p ≤ 0.036). However, 0.7 mm thick specimens had similar RTP after coffee thermocycling (p ≥ 0.265). Coffee thermocycling reduced the RTP values of 0.7 mm thick NLD (p = 0.032) and LDS (p = 0.008). NLD may endure the occlusal forces present in the posterior region. However, long-term coffee consumption may impair the esthetics of restorations particularly when thin NLD is used.
Collapse
|
23
|
Turksayar AAD, Donmez MB, Olcay EO, Demirel M, Demir E. Effect of printing orientation on the fracture strength of additively manufactured 3-unit interim fixed dental prostheses after aging. J Dent 2022; 124:104155. [DOI: 10.1016/j.jdent.2022.104155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 04/28/2022] [Accepted: 05/04/2022] [Indexed: 11/17/2022] Open
|
24
|
CAD/CAM Resin-Based Composites for Use in Long-Term Temporary Fixed Dental Prostheses. Polymers (Basel) 2021; 13:polym13203469. [PMID: 34685228 PMCID: PMC8539791 DOI: 10.3390/polym13203469] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Revised: 09/29/2021] [Accepted: 10/04/2021] [Indexed: 12/03/2022] Open
Abstract
The aim of this in vitro study was to analyse the performance of CAD/CAM resin-based composites for the fabrication of long-term temporary fixed dental prostheses (FDP) and to compare it to other commercially available alternative materials regarding its long-term stability. Four CAD/CAM materials [Structur CAD (SC), VITA CAD-Temp (CT), Grandio disc (GD), and Lava Esthetic (LE)] and two direct RBCs [(Structur 3 (S3) and LuxaCrown (LC)] were used to fabricate three-unit FDPs. 10/20 FDPs were subjected to thermal cycling and mechanical loading by chewing simulation and 10/20 FDPs were stored in distilled water. Two FDPs of each material were forwarded to additional image diagnostics prior and after chewing simulation. Fracture loads were measured and data were statistically analysed. SC is suitable for use as a long-term temporary (two years) three-unit FDP. In comparison to CT, SC featured significantly higher breaking forces (SC > 800 N; CT < 600 N) and the surface wear of the antagonists was (significantly) lower and the abrasion of the FDP was similar. The high breaking forces (1100–1327 N) of GD and the small difference compared to LE regarding flexural strength showed that the material might be used for the fabrication of three-unit FDPs. With the exception of S3, all analysed direct or indirect materials are suitable for the fabrication of temporary FDPs.
Collapse
|
25
|
Khorsandi D, Fahimipour A, Abasian P, Saber SS, Seyedi M, Ghanavati S, Ahmad A, De Stephanis AA, Taghavinezhaddilami F, Leonova A, Mohammadinejad R, Shabani M, Mazzolai B, Mattoli V, Tay FR, Makvandi P. 3D and 4D printing in dentistry and maxillofacial surgery: Printing techniques, materials, and applications. Acta Biomater 2021; 122:26-49. [PMID: 33359299 DOI: 10.1016/j.actbio.2020.12.044] [Citation(s) in RCA: 115] [Impact Index Per Article: 38.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 12/16/2020] [Accepted: 12/17/2020] [Indexed: 12/12/2022]
Abstract
3D and 4D printing are cutting-edge technologies for precise and expedited manufacturing of objects ranging from plastic to metal. Recent advances in 3D and 4D printing technologies in dentistry and maxillofacial surgery enable dentists to custom design and print surgical drill guides, temporary and permanent crowns and bridges, orthodontic appliances and orthotics, implants, mouthguards for drug delivery. In the present review, different 3D printing technologies available for use in dentistry are highlighted together with a critique on the materials available for printing. Recent reports of the application of these printed platformed are highlighted to enable readers appreciate the progress in 3D/4D printing in dentistry.
Collapse
|