1
|
Hu H, Ewert SD, Kollmeier B, Vickers D. Rate dependent neural responses of interaural-time-difference cues in fine-structure and envelope. PeerJ 2024; 12:e17104. [PMID: 38680894 PMCID: PMC11055513 DOI: 10.7717/peerj.17104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 02/22/2024] [Indexed: 05/01/2024] Open
Abstract
Advancements in cochlear implants (CIs) have led to a significant increase in bilateral CI users, especially among children. Yet, most bilateral CI users do not fully achieve the intended binaural benefit due to potential limitations in signal processing and/or surgical implant positioning. One crucial auditory cue that normal hearing (NH) listeners can benefit from is the interaural time difference (ITD), i.e., the time difference between the arrival of a sound at two ears. The ITD sensitivity is thought to be heavily relying on the effective utilization of temporal fine structure (very rapid oscillations in sound). Unfortunately, most current CIs do not transmit such true fine structure. Nevertheless, bilateral CI users have demonstrated sensitivity to ITD cues delivered through envelope or interaural pulse time differences, i.e., the time gap between the pulses delivered to the two implants. However, their ITD sensitivity is significantly poorer compared to NH individuals, and it further degrades at higher CI stimulation rates, especially when the rate exceeds 300 pulse per second. The overall purpose of this research thread is to improve spatial hearing abilities in bilateral CI users. This study aims to develop electroencephalography (EEG) paradigms that can be used with clinical settings to assess and optimize the delivery of ITD cues, which are crucial for spatial hearing in everyday life. The research objective of this article was to determine the effect of CI stimulation pulse rate on the ITD sensitivity, and to characterize the rate-dependent degradation in ITD perception using EEG measures. To develop protocols for bilateral CI studies, EEG responses were obtained from NH listeners using sinusoidal-amplitude-modulated (SAM) tones and filtered clicks with changes in either fine structure ITD (ITDFS) or envelope ITD (ITDENV). Multiple EEG responses were analyzed, which included the subcortical auditory steady-state responses (ASSRs) and cortical auditory evoked potentials (CAEPs) elicited by stimuli onset, offset, and changes. Results indicated that acoustic change complex (ACC) responses elicited by ITDENV changes were significantly smaller or absent compared to those elicited by ITDFS changes. The ACC morphologies evoked by ITDFS changes were similar to onset and offset CAEPs, although the peak latencies were longest for ACC responses and shortest for offset CAEPs. The high-frequency stimuli clearly elicited subcortical ASSRs, but smaller than those evoked by lower carrier frequency SAM tones. The 40-Hz ASSRs decreased with increasing carrier frequencies. Filtered clicks elicited larger ASSRs compared to high-frequency SAM tones, with the order being 40 > 160 > 80> 320 Hz ASSR for both stimulus types. Wavelet analysis revealed a clear interaction between detectable transient CAEPs and 40-Hz ASSRs in the time-frequency domain for SAM tones with a low carrier frequency.
Collapse
Affiliation(s)
- Hongmei Hu
- SOUND Lab, Cambridge Hearing Group, Department of Clinical Neuroscience, Cambridge University, Cambridge, United Kingdom
- Department of Medical Physics and Acoustics, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany
| | - Stephan D. Ewert
- Department of Medical Physics and Acoustics, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany
| | - Birger Kollmeier
- Department of Medical Physics and Acoustics, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany
| | - Deborah Vickers
- SOUND Lab, Cambridge Hearing Group, Department of Clinical Neuroscience, Cambridge University, Cambridge, United Kingdom
| |
Collapse
|
2
|
Sammeth CA, Brown AD, Greene NT, Tollin DJ. Interaural frequency mismatch jointly modulates neural brainstem binaural interaction and behavioral interaural time difference sensitivity in humans. Hear Res 2023; 437:108839. [PMID: 37429100 PMCID: PMC10529080 DOI: 10.1016/j.heares.2023.108839] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 06/12/2023] [Accepted: 07/04/2023] [Indexed: 07/12/2023]
Abstract
The binaural interaction component (BIC) of the auditory brainstem response (ABR) is the difference obtained after subtracting the sum of right and left ear ABRs from binaurally evoked ABRs. The BIC has attracted interest as a biomarker of binaural processing abilities. Best binaural processing is presumed to require spectrally-matched inputs at the two ears, but peripheral pathology and/or impacts of hearing devices can lead to mismatched inputs. Such mismatching can degrade behavioral sensitivity to interaural time difference (ITD) cues, but might be detected using the BIC. Here, we examine the effect of interaural frequency mismatch (IFM) on BIC and behavioral ITD sensitivity in audiometrically normal adult human subjects (both sexes). Binaural and monaural ABRs were recorded and BICs computed from subjects in response to narrowband tones. Left ear stimuli were fixed at 4000 Hz while right ear stimuli varied over a ∼2-octave range (re: 4000 Hz). Separately, subjects performed psychophysical lateralization tasks using the same stimuli to determine ITD discrimination thresholds jointly as a function of IFM and sound level. Results demonstrated significant effects of IFM on BIC amplitudes, with lower amplitudes in mismatched conditions than frequency-matched. Behavioral ITD discrimination thresholds were elevated at mismatched frequencies and lower sound levels, but also more sharply modulated by IFM at lower sound levels. Combinations of ITD, IFM and overall sound level that resulted in fused and lateralized percepts were bound by the empirically-measured BIC, and also by model predictions simulated using an established computational model of the brainstem circuit thought to generate the BIC.
Collapse
Affiliation(s)
- Carol A Sammeth
- Department of Physiology and Biophysics, University of Colorado School of Medicine, RC1-N: Rm 7106, 12800 E. 19th Avenue, Aurora, CO 80045, USA
| | - Andrew D Brown
- Department of Speech and Hearing Sciences, University of Washington, Seattle, WA 98105, USA
| | - Nathaniel T Greene
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, CO 80045, USA
| | - Daniel J Tollin
- Department of Physiology and Biophysics, University of Colorado School of Medicine, RC1-N: Rm 7106, 12800 E. 19th Avenue, Aurora, CO 80045, USA; Department of Otolaryngology, University of Colorado School of Medicine, Aurora, CO 80045, USA.
| |
Collapse
|
3
|
Eddins AC, Ozmeral EJ, Eddins DA. Aging alters across-hemisphere cortical dynamics during binaural temporal processing. Front Neurosci 2023; 16:1060172. [PMID: 36703999 PMCID: PMC9871896 DOI: 10.3389/fnins.2022.1060172] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Accepted: 12/16/2022] [Indexed: 01/11/2023] Open
Abstract
Differences in the timing and intensity of sounds arriving at the two ears provide fundamental binaural cues that help us localize and segregate sounds in the environment. Neural encoding of these cues is commonly represented asymmetrically in the cortex with stronger activation in the hemisphere contralateral to the perceived spatial location. Although advancing age is known to degrade the perception of binaural cues, less is known about how the neural representation of such cues is impacted by age. Here, we use electroencephalography (EEG) to investigate age-related changes in the hemispheric distribution of interaural time difference (ITD) encoding based on cortical auditory evoked potentials (CAEPs) and derived binaural interaction component (BIC) measures in ten younger and ten older normal-hearing adults. Sensor-level analyses of the CAEP and BIC showed age-related differences in global field power, where older listeners had significantly larger responses than younger for both binaural metrics. Source-level analyses showed hemispheric differences in auditory cortex activity for left and right lateralized stimuli in younger adults, consistent with a contralateral activation model for processing ITDs. Older adults, however, showed reduced hemispheric asymmetry across ITDs, despite having overall larger responses than younger adults. Further, when averaged across ITD condition to evaluate changes in cortical asymmetry over time, there was a significant shift in laterality corresponding to the peak components (P1, N1, P2) in the source waveform that also was affected by age. These novel results demonstrate across-hemisphere cortical dynamics during binaural temporal processing that are altered with advancing age.
Collapse
Affiliation(s)
- Ann Clock Eddins
- Department of Communication Sciences and Disorders, University of South Florida, Tampa, FL, United States
- School of Communication Sciences and Disorders, University of Central Florida, Orlando, FL, United States
| | - Erol J. Ozmeral
- Department of Communication Sciences and Disorders, University of South Florida, Tampa, FL, United States
| | - David A. Eddins
- Department of Communication Sciences and Disorders, University of South Florida, Tampa, FL, United States
| |
Collapse
|
4
|
Pieper SH, Hamze N, Brill S, Hochmuth S, Exter M, Polak M, Radeloff A, Buschermöhle M, Dietz M. Considerations for Fitting Cochlear Implants Bimodally and to the Single-Sided Deaf. Trends Hear 2022; 26:23312165221108259. [PMID: 35726211 PMCID: PMC9218456 DOI: 10.1177/23312165221108259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
When listening with a cochlear implant through one ear and acoustically through the other, binaural benefits and spatial hearing abilities are generally poorer than in other bilaterally stimulated configurations. With the working hypothesis that binaural neurons require interaurally matched inputs, we review causes for mismatch, their perceptual consequences, and experimental methods for mismatch measurements. The focus is on the three primary interaural dimensions of latency, frequency, and level. Often, the mismatch is not constant, but rather highly stimulus-dependent. We report on mismatch compensation strategies, taking into consideration the specific needs of the respective patient groups. Practical challenges typically faced by audiologists in the proposed fitting procedure are discussed. While improvement in certain areas (e.g., speaker localization) is definitely achievable, a more comprehensive mismatch compensation is a very ambitious endeavor. Even in the hypothetical ideal fitting case, performance is not expected to exceed that of a good bilateral cochlear implant user.
Collapse
Affiliation(s)
- Sabrina H Pieper
- Department of Medical Physics and Acoustic, University of Oldenburg, Oldenburg, Germany.,Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany
| | - Noura Hamze
- MED-EL Medical Electronics GmbH, Innsbruck, Austria
| | - Stefan Brill
- MED-EL Medical Electronics Germany GmbH, Starnberg, Germany
| | - Sabine Hochmuth
- Division of Otorhinolaryngology, University of Oldenburg, Oldenburg, Germany
| | - Mats Exter
- Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany.,Hörzentrum Oldenburg gGmbH, Oldenburg, Germany
| | - Marek Polak
- MED-EL Medical Electronics GmbH, Innsbruck, Austria
| | - Andreas Radeloff
- Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany.,Division of Otorhinolaryngology, University of Oldenburg, Oldenburg, Germany.,Research Center Neurosensory Science, University of Oldenburg, Oldenburg, Germany
| | | | - Mathias Dietz
- Department of Medical Physics and Acoustic, University of Oldenburg, Oldenburg, Germany.,Cluster of Excellence Hearing4all, University of Oldenburg, Oldenburg, Germany.,Research Center Neurosensory Science, University of Oldenburg, Oldenburg, Germany
| |
Collapse
|
5
|
Sammeth CA, Greene NT, Brown AD, Tollin DJ. Normative Study of the Binaural Interaction Component of the Human Auditory Brainstem Response as a Function of Interaural Time Differences. Ear Hear 2021; 42:629-643. [PMID: 33141776 PMCID: PMC8085190 DOI: 10.1097/aud.0000000000000964] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The binaural interaction component (BIC) of the auditory brainstem response (ABR) is obtained by subtracting the sum of the monaural right and left ear ABRs from the binaurally evoked ABR. The result is a small but prominent negative peak (herein called "DN1"), indicating a smaller binaural than summed ABR, which occurs around the latency of wave V or its roll-off slope. The BIC has been proposed to have diagnostic value as a biomarker of binaural processing abilities; however, there have been conflicting reports regarding the reliability of BIC measures in human subjects. The objectives of the current study were to: (1) examine prevalence of BIC across a large group of normal-hearing young adults; (2) determine effects of interaural time differences (ITDs) on BIC; and (3) examine any relationship between BIC and behavioral ITD discrimination acuity. DESIGN Subjects were 40 normal-hearing adults (20 males and 20 females), aged 21 to 48 years, with no history of otologic or neurologic disorders. Midline ABRs were recorded from electrodes at high forehead (Fz) referenced to the nape of the neck (near the seventh cervical vertebra), with Fpz (low forehead) as the ground. ABRs were also recorded with a conventional earlobe reference for comparison to midline results. Stimuli were 90 dB peSPL biphasic clicks. For BIC measurements, stimuli were presented in a block as interleaved right monaural, left monaural, and binaural stimuli with 2000+ presentations per condition. Four measurements were averaged for a total of 8000+ stimuli per analyzed waveform. BIC was measured for ITD = 0 (simultaneous bilateral) and for ITDs of ±500 and ±750 µs. Subjects separately performed a lateralization task, using the same stimuli, to determine ITD discrimination thresholds. RESULTS An identifiable BIC DN1 was obtained in 39 of 40 subjects at ITD = 0 µs in at least one of two measurement sessions, but was seen in lesser numbers of subjects in a single session or as ITD increased. BIC was most often seen when a subject was relaxed or sleeping, and less often when they fidgeted or reported neck tension, suggesting myogenic activity as a possible factor in disrupting BIC measurements. Mean BIC latencies systematically increased with increasing ITD, and mean BIC amplitudes tended to decrease. However, across subjects, there was no significant relationship between the amplitude or latency of the BIC and behavioral ITD thresholds. CONCLUSIONS Consistent with previous studies, measurement of the BIC was time consuming and a BIC was sometimes difficult to obtain in awake normal-hearing subjects. The BIC will thus continue to be of limited clinical utility unless stimulus parameters and measurement techniques can be identified that produce a more robust response. Nonetheless, modulation of BIC characteristics by ITD supports the concept that the ABR BIC indexes aspects of binaural brainstem processing and thus may prove useful in selected research applications, e.g. in the examination of populations expected to have aberrant binaural signal processing ability.
Collapse
Affiliation(s)
- Carol A. Sammeth
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado, USA
| | - Nathaniel T. Greene
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado, USA
| | - Andrew D. Brown
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington, USA
| | - Daniel J Tollin
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado, USA
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado, USA
| |
Collapse
|
6
|
Beck T, Kilchling T, Reese S, Brühschwein A, Meyer-Lindenberg A. Influence of storage on the quality of conventional CT and µCT-imaging for the middle and inner cat ear. Anat Sci Int 2019; 95:190-201. [PMID: 31728859 DOI: 10.1007/s12565-019-00509-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Accepted: 11/04/2019] [Indexed: 10/25/2022]
Abstract
The aim of this study was to analyze whether different fixation methods such as freezing or formaldehyde storage for different periods of time have an influence on the recognition of anatomical relevant structures in the middle and inner ear of the cat with conventional computed tomography (cCT) and micro-computed tomography (µCT). Besides, effects of freeze-thaw cycles on determined structures of the ear were investigated by means of histological slices. Three veterinarians with different radiologic expertise evaluated the scans of 30 dissected cat ears anonymously and scored predefined structures in a five-point scale with reference to visually sharp reproducibility and perfect image quality. The total scores of the different fixation groups as well as the ears within a group were compared with each other. Furthermore, an intra-reader examination including an evaluation of the identifiability of specified structures was performed for both imaging methods. cCT as well as µCT-scans have a very low variation coefficient of 1.6% and 2.3%, respectively. The results for the alterations between the different fixation methods show that the changes for cCT-scans are negligible, as the percentage alteration compared to fresh samples ranges in a very small interval with values from 1.0% better to 1.2% worse. µCT-scans are more influenced by the fixation method with a range from 1.3% better to 6.9% worse values. The scans mostly deteriorated after two freeze-thaw cycles (1.8% worse) and after storing the samples for 1 (2.4% worse), respectively, and 3 weeks in formaldehyde (6.9% worse).
Collapse
Affiliation(s)
- Tobias Beck
- Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Veterinärstraße 13, 80539, Munich, Germany. .,, Wolfratshausen, Germany.
| | - T Kilchling
- Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Veterinärstraße 13, 80539, Munich, Germany.,, Baden-Baden, Germany
| | - S Reese
- Veterinary Department, Institute of Veterinary Anatomy, Histology and Embryology, Ludwig-Maximilians-University Munich, Veterinärstraße 13, 80539, Munich, Germany
| | - A Brühschwein
- Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Veterinärstraße 13, 80539, Munich, Germany
| | - Andrea Meyer-Lindenberg
- Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians-University Munich, Veterinärstraße 13, 80539, Munich, Germany
| |
Collapse
|
7
|
Brown AD, Anbuhl KL, Gilmer JI, Tollin DJ. Between-ear sound frequency disparity modulates a brain stem biomarker of binaural hearing. J Neurophysiol 2019; 122:1110-1122. [PMID: 31314646 PMCID: PMC6766741 DOI: 10.1152/jn.00057.2019] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 07/02/2019] [Accepted: 07/03/2019] [Indexed: 11/22/2022] Open
Abstract
The auditory brain stem response (ABR) is an evoked potential that indexes a cascade of neural events elicited by sound. In the present study we evaluated the influence of sound frequency on a derived component of the ABR known as the binaural interaction component (BIC). Specifically, we evaluated the effect of acoustic interaural (between-ear) frequency mismatch on BIC amplitude. Goals were to 1) increase basic understanding of sound features that influence this long-studied auditory potential and 2) gain insight about the persistence of the BIC with interaural electrode mismatch in human users of bilateral cochlear implants, presently a limitation on the prospective utility of the BIC in audiological settings. Data were collected in an animal model that is audiometrically similar to humans, the chinchilla (Chinchilla lanigera; 6 females). Frequency disparities and amplitudes of acoustic stimuli were varied over broad ranges, and associated variation of BIC amplitude was quantified. Subsequently, responses were simulated with the use of established models of the brain stem pathway thought to underlie the BIC. Collectively, the data demonstrate that at high sound intensities (≥85 dB SPL), the acoustically elicited BIC persisted with interaurally disparate stimulation (click frequencies ≥1.5 octaves apart). However, sharper tuning emerged at moderate sound intensities (65 dB SPL), with the largest BIC occurring for stimulus frequencies within ~0.8 octaves, equivalent to ±1 mm in cochlear place. Such responses were consistent with simulated responses of the presumed brain stem generator of the BIC, the lateral superior olive. The data suggest that leveraging focused electrical stimulation strategies could improve BIC-based bilateral cochlear implant fitting outcomes.NEW & NOTEWORTHY Traditional hearing tests evaluate each ear independently. Diagnosis and treatment of binaural hearing dysfunction remains a basic challenge for hearing clinicians. We demonstrate in an animal model that the prospective utility of a noninvasive electrophysiological signature of binaural function, the binaural interaction component (BIC), depends strongly on the intensity of auditory stimulation. Data suggest that more informative BIC measurements could be obtained with clinical protocols leveraging stimuli restricted in effective bandwidth.
Collapse
Affiliation(s)
- Andrew D Brown
- Department of Speech and Hearing Sciences, University of Washington, Seattle, Washington
| | - Kelsey L Anbuhl
- Center for Neural Science, New York University, New York, New York
| | - Jesse I Gilmer
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado
- Neuroscience Training Program, University of Colorado School of Medicine, Aurora, Colorado
| | - Daniel J Tollin
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado
- Neuroscience Training Program, University of Colorado School of Medicine, Aurora, Colorado
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado
| |
Collapse
|
8
|
Van Eeckhoutte M, Spirrov D, Wouters J, Francart T. Objective Binaural Loudness Balancing Based on 40-Hz Auditory Steady-State Responses. Part II: Asymmetric and Bimodal Hearing. Trends Hear 2018; 22:2331216518805363. [PMID: 30334496 PMCID: PMC6196612 DOI: 10.1177/2331216518805363] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
In Part I, we investigated 40-Hz auditory steady-state response (ASSR) amplitudes for the use of objective loudness balancing across the ears for normal-hearing participants and found median across-ear ratios in ASSR amplitudes close to 1. In this part, we further investigated whether the ASSR can be used to estimate binaural loudness balance for listeners with asymmetric hearing, for whom binaural loudness balancing is of particular interest. We tested participants with asymmetric hearing and participants with bimodal hearing, who hear with electrical stimulation through a cochlear implant (CI) in one ear and with acoustical stimulation in the other ear. Behavioral loudness balancing was performed at different percentages of the dynamic range. Acoustical carrier frequencies were 500, 1000, or 2000 Hz, and CI channels were stimulated in apical or middle regions in the cochlea. For both groups, the ASSR amplitudes at balanced loudness levels were similar for the two ears, with median ratios between left and right ear stimulation close to 1. However, individual variability was observed. For participants with asymmetric hearing loss, the difference between the behavioral balanced levels and the ASSR-predicted balanced levels was smaller than 10 dB in 50% and 56% of cases, for 500 Hz and 2000 Hz, respectively. For bimodal listeners, these percentages were 89% and 60%. Apical CI channels yielded significantly better results (median difference near 0 dB) than middle CI channels, which had a median difference of −7.25 dB.
Collapse
Affiliation(s)
| | | | - Jan Wouters
- 1 ExpORL, Department of Neurosciences, KU Leuven, Belgium
| | - Tom Francart
- 1 ExpORL, Department of Neurosciences, KU Leuven, Belgium
| |
Collapse
|
9
|
Corrective binaural processing for bilateral cochlear implant patients. PLoS One 2018; 13:e0187965. [PMID: 29351279 PMCID: PMC5774684 DOI: 10.1371/journal.pone.0187965] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Accepted: 10/30/2017] [Indexed: 11/19/2022] Open
Abstract
Although bilateral cochlear implant users receive input to both ears, they nonetheless have relatively poor localization abilities in the horizontal plane. This is likely because of the two binaural cues, they have good sensitivity to interaural differences of level (inter-aural level differences, or ILDs), but not those of time (inter-aural time differences; ITDs). Here, localization performance is assessed in six bilateral cochlear implant patients when instantaneous ITDs are measured and converted to ILDs, a strategy that results in larger-than-typical ILDs. The added ILDs are corrective, in that they are derived from individual listener performance across both frequency and azimuth, so that they are small where a listener performs well, and increase as performance deviates from ideal. Results show significantly improved localization performance as a result of this strategy, with two of the six listeners achieving levels of performance typically observed in NH listeners.
Collapse
|
10
|
Test-Retest Reliability of the Binaural Interaction Component of the Auditory Brainstem Response. Ear Hear 2018; 37:e291-301. [PMID: 27232069 DOI: 10.1097/aud.0000000000000315] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The binaural interaction component (BIC) is the residual auditory brainstem response (ABR) obtained after subtracting the sum of monaurally evoked from binaurally evoked ABRs. The DN1 peak-the first negative peak of the BIC-has been postulated to have diagnostic value as a biomarker for binaural hearing abilities. Indeed, not only do DN1 amplitudes depend systematically upon binaural cues to location (interaural time and level differences), but they are also predictive of central hearing deficits in humans. A prominent issue in using BIC measures as a diagnostic biomarker is that DN1 amplitudes not only exhibit considerable variability across subjects, but also within subjects across different measurement sessions. DESIGN In this study, the authors investigate the DN1 amplitude measurement reliability by conducting repeated measurements on different days in eight adult guinea pigs. RESULTS Despite consistent ABR thresholds, ABR and DN1 amplitudes varied between and within subjects across recording sessions. However, the study analysis reveals that DN1 amplitudes varied proportionally with parent monaural ABR amplitudes, suggesting that common experimental factors likely account for the variability in both waveforms. Despite this variability, the authors show that the shape of the dependence between DN1 amplitude and interaural time difference is preserved. The authors then provide a BIC normalization strategy using monaural ABR amplitude that reduces the variability of DN1 peak measurements. Finally, the authors evaluate this normalization strategy in the context of detecting changes of the DN1 amplitude-to-interaural time difference relationship. CONCLUSIONS The study results indicate that the BIC measurement variability can be reduced by a factor of two by performing a simple and objective normalization operation. The authors discuss the potential for this normalized BIC measure as a biomarker for binaural hearing.
Collapse
|
11
|
Binaural integration: a challenge to overcome for children with hearing loss. Curr Opin Otolaryngol Head Neck Surg 2017; 25:514-519. [DOI: 10.1097/moo.0000000000000413] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
12
|
Fitzgerald MB, Prosolovich K, Tan CT, Glassman EK, Svirsky MA. Self-Selection of Frequency Tables with Bilateral Mismatches in an Acoustic Simulation of a Cochlear Implant. J Am Acad Audiol 2017; 28:385-394. [PMID: 28534729 PMCID: PMC5563263 DOI: 10.3766/jaaa.15077] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Many recipients of bilateral cochlear implants (CIs) may have differences in electrode insertion depth. Previous reports indicate that when a bilateral mismatch is imposed, performance on tests of speech understanding or sound localization becomes worse. If recipients of bilateral CIs cannot adjust to a difference in insertion depth, adjustments to the frequency table may be necessary to maximize bilateral performance. PURPOSE The purpose of this study was to examine the feasibility of using real-time manipulations of the frequency table to offset any decrements in performance resulting from a bilateral mismatch. RESEARCH DESIGN A simulation of a CI was used because it allows for explicit control of the size of a bilateral mismatch. Such control is not available with users of CIs. STUDY SAMPLE A total of 31 normal-hearing young adults participated in this study. DATA COLLECTION AND ANALYSIS Using a CI simulation, four bilateral mismatch conditions (0, 0.75, 1.5, and 3 mm) were created. In the left ear, the analysis filters and noise bands of the CI simulation were the same. In the right ear, the noise bands were shifted higher in frequency to simulate a bilateral mismatch. Then, listeners selected a frequency table in the right ear that was perceived as maximizing bilateral speech intelligibility. Word-recognition scores were then assessed for each bilateral mismatch condition. Listeners were tested with both a standard frequency table, which preserved a bilateral mismatch, or with their self-selected frequency table. RESULTS Consistent with previous reports, bilateral mismatches of 1.5 and 3 mm yielded decrements in word recognition when the standard table was used in both ears. However, when listeners used the self-selected frequency table, performance was the same regardless of the size of the bilateral mismatch. CONCLUSIONS Self-selection of a frequency table appears to be a feasible method for ameliorating the negative effects of a bilateral mismatch. These data may have implications for recipients of bilateral CIs who cannot adapt to a bilateral mismatch, because they suggest that (1) such individuals may benefit from modification of the frequency table in one ear and (2) self-selection of a "most intelligible" frequency table may be a useful tool for determining how the frequency table should be altered to optimize speech recognition.
Collapse
Affiliation(s)
- Matthew B. Fitzgerald
- Department of Otolaryngology – Head and Neck Surgery, Stanford Ear Institute, Stanford University, Palo Alto, CA
- Department of Otolaryngology, New York University School of Medicine, New York, NY
| | - Ksenia Prosolovich
- Department of Otolaryngology, University of Southern California, Los Angeles, CA
| | - Chin-Tuan Tan
- Department of Otolaryngology, New York University School of Medicine, New York, NY
| | | | - Mario A. Svirsky
- Department of Otolaryngology, New York University School of Medicine, New York, NY
| |
Collapse
|
13
|
Undurraga JA, Haywood NR, Marquardt T, McAlpine D. Neural Representation of Interaural Time Differences in Humans-an Objective Measure that Matches Behavioural Performance. J Assoc Res Otolaryngol 2016; 17:591-607. [PMID: 27628539 PMCID: PMC5112218 DOI: 10.1007/s10162-016-0584-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Accepted: 08/15/2016] [Indexed: 12/22/2022] Open
Abstract
Humans, and many other species, exploit small differences in the timing of sounds at the two ears (interaural time difference, ITD) to locate their source and to enhance their detection in background noise. Despite their importance in everyday listening tasks, however, the neural representation of ITDs in human listeners remains poorly understood, and few studies have assessed ITD sensitivity to a similar resolution to that reported perceptually. Here, we report an objective measure of ITD sensitivity in electroencephalography (EEG) signals to abrupt modulations in the interaural phase of amplitude-modulated low-frequency tones. Specifically, we measured following responses to amplitude-modulated sinusoidal signals (520-Hz carrier) in which the stimulus phase at each ear was manipulated to produce discrete interaural phase modulations at minima in the modulation cycle-interaural phase modulation following responses (IPM-FRs). The depth of the interaural phase modulation (IPM) was defined by the sign and the magnitude of the interaural phase difference (IPD) transition which was symmetric around zero. Seven IPM depths were assessed over the range of ±22 ° to ±157 °, corresponding to ITDs largely within the range experienced by human listeners under natural listening conditions (120 to 841 μs). The magnitude of the IPM-FR was maximal for IPM depths in the range of ±67.6 ° to ±112.6 ° and correlated well with performance in a behavioural experiment in which listeners were required to discriminate sounds containing IPMs from those with only static IPDs. The IPM-FR provides a sensitive measure of binaural processing in the human brain and has a potential to assess temporal binaural processing.
Collapse
Affiliation(s)
- Jaime A Undurraga
- Department Linguistics, The Australian Hearing Hub, Macquarie University, 16 University Avenue, Sydney, NSW, 2109, Australia.
- UCL Ear Institute, University College London, 332 Gray's Inn Rd., London, WC1X8EE, UK.
| | - Nick R Haywood
- Department Linguistics, The Australian Hearing Hub, Macquarie University, 16 University Avenue, Sydney, NSW, 2109, Australia
- UCL Ear Institute, University College London, 332 Gray's Inn Rd., London, WC1X8EE, UK
| | - Torsten Marquardt
- UCL Ear Institute, University College London, 332 Gray's Inn Rd., London, WC1X8EE, UK
| | - David McAlpine
- Department Linguistics, The Australian Hearing Hub, Macquarie University, 16 University Avenue, Sydney, NSW, 2109, Australia
- UCL Ear Institute, University College London, 332 Gray's Inn Rd., London, WC1X8EE, UK
| |
Collapse
|
14
|
Litovsky RY, Gordon K. Bilateral cochlear implants in children: Effects of auditory experience and deprivation on auditory perception. Hear Res 2016; 338:76-87. [PMID: 26828740 PMCID: PMC5647834 DOI: 10.1016/j.heares.2016.01.003] [Citation(s) in RCA: 70] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2015] [Revised: 01/07/2016] [Accepted: 01/11/2016] [Indexed: 11/29/2022]
Abstract
Spatial hearing skills are essential for children as they grow, learn and play. These skills provide critical cues for determining the locations of sources in the environment, and enable segregation of important sounds, such as speech, from background maskers or interferers. Spatial hearing depends on availability of monaural cues and binaural cues. The latter result from integration of inputs arriving at the two ears from sounds that vary in location. The binaural system has exquisite mechanisms for capturing differences between the ears in both time of arrival and intensity. The major cues that are thus referred to as being vital for binaural hearing are: interaural differences in time (ITDs) and interaural differences in levels (ILDs). In children with normal hearing (NH), spatial hearing abilities are fairly well developed by age 4-5 years. In contrast, most children who are deaf and hear through cochlear implants (CIs) do not have an opportunity to experience normal, binaural acoustic hearing early in life. These children may function by having to utilize auditory cues that are degraded with regard to numerous stimulus features. In recent years there has been a notable increase in the number of children receiving bilateral CIs, and evidence suggests that while having two CIs helps them function better than when listening through a single CI, these children generally perform worse than their NH peers. This paper reviews some of the recent work on bilaterally implanted children. The focus is on measures of spatial hearing, including sound localization, release from masking for speech understanding in noise and binaural sensitivity using research processors. Data from behavioral and electrophysiological studies are included, with a focus on the recent work of the authors and their collaborators. The effects of auditory plasticity and deprivation on the emergence of binaural and spatial hearing are discussed along with evidence for reorganized processing from both behavioral and electrophysiological studies. The consequences of both unilateral and bilateral auditory deprivation during development suggest that the relevant set of issues is highly complex with regard to successes and the limitations experienced by children receiving bilateral cochlear implants. This article is part of a Special Issue entitled .
Collapse
Affiliation(s)
- Ruth Y Litovsky
- University of Wisconsin-Madison, 1500 Highland Ave, Madison, WI, 53705, United States.
| | | |
Collapse
|
15
|
Effects of interaural pitch matching and auditory image centering on binaural sensitivity in cochlear implant users. Ear Hear 2016; 36:e62-8. [PMID: 25565660 DOI: 10.1097/aud.0000000000000135] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES In bilateral cochlear implant users, electrodes mapped to the same frequency range in each ear may stimulate different places in each cochlea due to an insertion depth difference of electrode arrays. This interaural place of stimulation mismatch can lead to problems with auditory image fusion and sensitivity to binaural cues, which may explain the large localization errors seen in many patients. Previous work has shown that interaural place of stimulation mismatch can lead to off-centered auditory images being perceived even though interaural time and level differences (ITD and ILD, respectively) were zero. Large interaural mismatches reduced the ability to use ITDs for auditory image lateralization. In contrast, lateralization with ILDs was still possible but the mapping of ILDs to spatial locations was distorted. This study extends the previous work by systematically investigating the effect of interaural place of stimulation mismatch on ITD and ILD sensitivity directly and examining whether "centering" methods can be used to mitigate some of the negative effects of interaural place of stimulation mismatch. DESIGN Interaural place of stimulation mismatch was deliberately introduced for this study. Interaural pitch-matching techniques were used to identify a pitch-matched pair of electrodes across the ears approximately at the center of the array. Mismatched pairs were then created by maintaining one of the pitch-matched electrodes constant, and systematically varying the contralateral electrode by two, four, or eight electrode positions (corresponding to approximately 1.5, 3, and 6 mm of interaural place of excitation differences). The stimuli were 300 msec, constant amplitude pulse trains presented at 100 pulses per second. ITD and ILD just noticeable differences (JNDs) were measured using a method of constant stimuli with a two-interval, two-alternative forced choice task. The results were fit with a psychometric function to obtain the JNDs. In experiment I, ITD and ILD JNDs were measured as a function of the simulated place of stimulation mismatch. In experiment II, the auditory image of mismatched pair was centered by adjusting the stimulation level according to a lateralization task. ITD and ILD JNDs were then remeasured and compared with the results of experiment I. RESULTS ITD and ILD JNDs were best (lowest thresholds) for pairs of electrodes at or near the pitch-matched pair. Thresholds increased systematically with increasing amounts of interaural mismatch. Deliberate and careful centering of auditory images did not significantly improve ITD JNDs but did improve ILD JNDs at very large amounts of simulated mismatch. CONCLUSIONS Interaural place of stimulation mismatch decreases sensitivity to binaural cues that are important for accurate sound localization. However, deliberate and careful centering of auditory images does not seem to significantly counteract the effects of mismatch. Hence, to obtain maximal sound localization benefits of bilateral implantation, clinical and surgical techniques are needed that take into account differences in electrode array insertion depths across the ears.
Collapse
|
16
|
Hu H, Kollmeier B, Dietz M. Suitability of the Binaural Interaction Component for Interaural Electrode Pairing of Bilateral Cochlear Implants. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2016; 894:57-64. [PMID: 27080646 DOI: 10.1007/978-3-319-25474-6_7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Although bilateral cochlear implants (BiCIs) have succeeded in improving the spatial hearing performance of bilateral CI users, the overall performance is still not comparable with normal hearing listeners. Limited success can be partially caused by an interaural mismatch of the place-of-stimulation in each cochlea. Pairing matched interaural CI electrodes and stimulating them with the same frequency band is expected to facilitate binaural functions such as binaural fusion, localization, or spatial release from masking. It has been shown in animal experiments that the magnitude of the binaural interaction component (BIC) derived from the wave-eV decreases for increasing interaural place of stimulation mismatch. This motivated the investigation of the suitability of an electroencephalography-based objective electrode-frequency fitting procedure based on the BIC for BiCI users. A 61 channel monaural and binaural electrically evoked auditory brainstem response (eABR) recording was performed in 7 MED-EL BiCI subjects so far. These BiCI subjects were directly stimulated at 60% dynamic range with 19.9 pulses per second via a research platform provided by the University of Innsbruck (RIB II). The BIC was derived for several interaural electrode pairs by subtracting the response from binaural stimulation from their summed monaural responses. The BIC based pairing results are compared with two psychoacoustic pairing methods: interaural pulse time difference sensitivity and interaural pitch matching. The results for all three methods analyzed as a function of probe electrode allow for determining a matched pair in more than half of the subjects, with a typical accuracy of ± 1 electrode. This includes evidence for statistically significant tuning of the BIC as a function of probe electrode in human subjects. However, results across the three conditions were sometimes not consistent. These discrepancies will be discussed in the light of pitch plasticity versus less plastic brainstem processing.
Collapse
Affiliation(s)
- Hongmei Hu
- Medizinische Physik, Universität Oldenburg, Cluster of Excellence "Hearing4all", 26111, Oldenburg, Germany.
| | - Birger Kollmeier
- Medizinische Physik, Universität Oldenburg, Cluster of Excellence "Hearing4all", 26111, Oldenburg, Germany
| | - Mathias Dietz
- Medizinische Physik, Universität Oldenburg, Cluster of Excellence "Hearing4all", 26111, Oldenburg, Germany
| |
Collapse
|
17
|
Hu H, Dietz M. Comparison of Interaural Electrode Pairing Methods for Bilateral Cochlear Implants. Trends Hear 2015; 19:19/0/2331216515617143. [PMID: 26631108 PMCID: PMC4771032 DOI: 10.1177/2331216515617143] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
In patients with bilateral cochlear implants (CIs), pairing matched interaural electrodes and stimulating them with the same frequency band is expected to facilitate binaural functions such as binaural fusion, localization, and spatial release from masking. Because clinical procedures typically do not include patient-specific interaural electrode pairing, it remains the case that each electrode is allocated to a generic frequency range, based simply on the electrode number. Two psychoacoustic techniques for determining interaurally paired electrodes have been demonstrated in several studies: interaural pitch comparison and interaural time difference (ITD) sensitivity. However, these two methods are rarely, if ever, compared directly. A third, more objective method is to assess the amplitude of the binaural interaction component (BIC) derived from electrically evoked auditory brainstem responses for different electrode pairings; a method has been demonstrated to be a potential candidate for bilateral CI users. Here, we tested all three measures in the same eight CI users. We found good correspondence between the electrode pair producing the largest BIC and the electrode pair producing the maximum ITD sensitivity. The correspondence between the pairs producing the largest BIC and the pitch-matched electrode pairs was considerably weaker, supporting the previously proposed hypothesis that whilst place pitch might adapt over time to accommodate mismatched inputs, sensitivity to ITDs does not adapt to the same degree.
Collapse
Affiliation(s)
- Hongmei Hu
- Medizinische Physik, Universität Oldenburg and Cluster of Excellence "Hearing4all", Germany
| | - Mathias Dietz
- Medizinische Physik, Universität Oldenburg and Cluster of Excellence "Hearing4all", Germany
| |
Collapse
|
18
|
Jang JH, Lee HS, Oh SH, Park MH. Efficacy of the cat deafening method: Co-administration of ethacrynic acid and kanamycin. Acta Otolaryngol 2015; 136:289-92. [PMID: 26605909 DOI: 10.3109/00016489.2015.1110751] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE This study was designed to determine if hearing status monitoring during intravenous infusion of EA reduces individual variability and to evaluate the correlation between EA dose and Bwt. MATERIALS AND METHODS Twenty-five cats with the mean age of 24 ± 3.7 weeks (range = 20.6-28.3) and a mean weight of 3.21 ± 0.84 kg (range = 1.9-5.1) were administered a subcutaneous injection of KM (300 mg/kg) followed by an intravenous infusion of EA (1 mg/min). Click-evoked auditory brainstem responses (ABRs) were recorded to monitor hearing during the infusion. When ABR thresholds exceeded a 90 dB sound pressure level, the infusion of EA was terminated. Histopathology forapex, middle, and base sections of the cochlea were examined after 6 months. RESULTS The dose of EA was optimized for deafening through simultaneous ABR measurements. Bwt was positively correlated with EA dose (mg) (p < 0.001, R(2) = 0.548), which was different from a study previously reported. Cochlear histopathology assessments revealed an absence of organ of Corti in the majority of cochleae. CONCLUSION Co-administration of kanamycin (KM) and ethacrynic acid (EA) was an easy and effective method for deafening procedures in adult animals. Body weight (Bwt) was positively correlated with EA dose (mg) and an optimal EA dose can be calculated.
Collapse
Affiliation(s)
- Jeong Hun Jang
- a Department of Otorhinolaryngology , Kyungpook National University College of Medicine , Daegu , Korea
| | - Ho Sun Lee
- b Department of Otorhinolaryngology , Boramae Medical Center, Seoul Metropolitan Government-Seoul National University , Seoul , Korea
| | - Seung Ha Oh
- c Department of Otorhinolarynogology , Seoul National University College of Medicine , Seoul , Korea
- d Research Center for Sensory Organs, Medical Research Center, Seoul National University College of Medicine , Seoul , Korea
| | - Min-Hyun Park
- b Department of Otorhinolaryngology , Boramae Medical Center, Seoul Metropolitan Government-Seoul National University , Seoul , Korea
| |
Collapse
|
19
|
Highly Flexible Silicone Coated Neural Array for Intracochlear Electrical Stimulation. BIOMED RESEARCH INTERNATIONAL 2015; 2015:109702. [PMID: 26236714 PMCID: PMC4509491 DOI: 10.1155/2015/109702] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2014] [Accepted: 01/22/2015] [Indexed: 11/17/2022]
Abstract
We present an effective method for tailoring the flexibility of a commercial thin-film polymer electrode array for intracochlear electrical stimulation. Using a pneumatically driven dispensing system, an average 232 ± 64 μm (mean ± SD) thickness layer of silicone adhesive coating was applied to stiffen the underside of polyimide multisite arrays. Additional silicone was applied to the tip to protect neural tissue during insertion and along the array to improve surgical handling. Each array supported 20 platinum sites (180 μm dia., 250 μm pitch), spanning nearly 28 mm in length and 400 μm in width. We report an average intracochlear stimulating current threshold of 170 ± 93 μA to evoke an auditory brainstem response in 7 acutely deafened felines. A total of 10 arrays were each inserted through a round window approach into the cochlea's basal turn of eight felines with one delamination occurring upon insertion (preliminary results of the in vivo data presented at the 48th Annual Meeting American Neurotology Society, Orlando, FL, April 2013, and reported in Van Beek-King 2014). Using microcomputed tomography imaging (50 μm resolution), distances ranging from 100 to 565 μm from the cochlea's central modiolus were measured. Our method combines the utility of readily available commercial devices with a straightforward postprocessing step on the order of 24 hours.
Collapse
|
20
|
Binaural fusion and listening effort in children who use bilateral cochlear implants: a psychoacoustic and pupillometric study. PLoS One 2015; 10:e0117611. [PMID: 25668423 PMCID: PMC4323344 DOI: 10.1371/journal.pone.0117611] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2014] [Accepted: 12/29/2014] [Indexed: 11/23/2022] Open
Abstract
Bilateral cochlear implants aim to provide hearing to both ears for children who are deaf and promote binaural/spatial hearing. Benefits are limited by mismatched devices and unilaterally-driven development which could compromise the normal integration of left and right ear input. We thus asked whether children hear a fused image (ie. 1 vs 2 sounds) from their bilateral implants and if this “binaural fusion” reduces listening effort. Binaural fusion was assessed by asking 25 deaf children with cochlear implants and 24 peers with normal hearing whether they heard one or two sounds when listening to bilaterally presented acoustic click-trains/electric pulses (250 Hz trains of 36 ms presented at 1 Hz). Reaction times and pupillary changes were recorded simultaneously to measure listening effort. Bilaterally implanted children heard one image of bilateral input less frequently than normal hearing peers, particularly when intensity levels on each side were balanced. Binaural fusion declined as brainstem asymmetries increased and age at implantation decreased. Children implanted later had access to acoustic input prior to implantation due to progressive deterioration of hearing. Increases in both pupil diameter and reaction time occurred as perception of binaural fusion decreased. Results indicate that, without binaural level cues, children have difficulty fusing input from their bilateral implants to perceive one sound which costs them increased listening effort. Brainstem asymmetries exacerbate this issue. By contrast, later implantation, reflecting longer access to bilateral acoustic hearing, may have supported development of auditory pathways underlying binaural fusion. Improved integration of bilateral cochlear implant signals for children is required to improve their binaural hearing.
Collapse
|
21
|
Mesnildrey Q, Macherey O. Simulating the dual-peak excitation pattern produced by bipolar stimulation of a cochlear implant: effects on speech intelligibility. Hear Res 2014; 319:32-47. [PMID: 25449010 DOI: 10.1016/j.heares.2014.11.001] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2014] [Revised: 10/28/2014] [Accepted: 11/05/2014] [Indexed: 10/24/2022]
Abstract
Several electrophysiological and psychophysical studies have shown that the spatial excitation pattern produced by bipolar stimulation of a cochlear implant (CI) can have a dual-peak shape. The perceptual effects of this dual-peak shape were investigated using noise-vocoded CI simulations in which synthesis filters were designed to simulate the spread of neural activity produced by various electrode configurations, as predicted by a simple cochlear model. Experiments 1 and 2 tested speech recognition in the presence of a concurrent speech masker for various sets of single-peak and dual-peak synthesis filters and different numbers of channels. Similarly as results obtained in real CIs, both monopolar (MP, single-peak) and bipolar (BP + 1, dual-peak) simulations showed a plateau of performance above 8 channels. The benefit of increasing the number of channels was also lower for BP + 1 than for MP. This shows that channel interactions in BP + 1 become especially deleterious for speech intelligibility when a simulated electrode acts both as an active and as a return electrode for different channels because envelope information from two different analysis bands are being conveyed to the same spectral location. Experiment 3 shows that these channel interactions are even stronger in wide BP configuration (BP + 5), likely because the interfering speech envelopes are less correlated than in narrow BP + 1. Although the exact effects of dual- or multi-peak excitation in real CIs remain to be determined, this series of experiments suggest that multipolar stimulation strategies, such as bipolar or tripolar, should be controlled to avoid neural excitation in the vicinity of the return electrodes.
Collapse
Affiliation(s)
- Quentin Mesnildrey
- LMA-CNRS, UPR 7051, Aix-Marseille Univ., Centrale Marseille, 31 Chemin Joseph Aiguier, 13402 Marseille Cedex 20, France.
| | - Olivier Macherey
- LMA-CNRS, UPR 7051, Aix-Marseille Univ., Centrale Marseille, 31 Chemin Joseph Aiguier, 13402 Marseille Cedex 20, France
| |
Collapse
|
22
|
Hartley DEH, Isaiah A. Envelope enhancement increases cortical sensitivity to interaural envelope delays with acoustic and electric hearing. PLoS One 2014; 9:e104097. [PMID: 25093417 PMCID: PMC4122409 DOI: 10.1371/journal.pone.0104097] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2013] [Accepted: 07/10/2014] [Indexed: 11/20/2022] Open
Abstract
Evidence from human psychophysical and animal electrophysiological studies suggests that sensitivity to interaural time delay (ITD) in the modulating envelope of a high-frequency carrier can be enhanced using half-wave rectified stimuli. Recent evidence has shown potential benefits of equivalent electrical stimuli to deaf individuals with bilateral cochlear implants (CIs). In the current study we assessed the effects of envelope shape on ITD sensitivity in the primary auditory cortex of normal-hearing ferrets, and profoundly-deaf animals with bilateral CIs. In normal-hearing animals, cortical sensitivity to ITDs (±1 ms in 0.1-ms steps) was assessed in response to dichotically-presented i) sinusoidal amplitude-modulated (SAM) and ii) half-wave rectified (HWR) tones (100-ms duration; 70 dB SPL) presented at the best-frequency of the unit over a range of modulation frequencies. In separate experiments, adult ferrets were deafened with neomycin administration and bilaterally-implanted with intra-cochlear electrode arrays. Electrically-evoked auditory brainstem responses (EABRs) were recorded in response to bipolar electrical stimulation of the apical pair of electrodes with singe biphasic current pulses (40 µs per phase) over a range of current levels to measure hearing thresholds. Subsequently, we recorded cortical sensitivity to ITDs (±800 µs in 80-µs steps) within the envelope of SAM and HWR biphasic-pulse trains (40 µs per phase; 6000 pulses per second, 100-ms duration) over a range of modulation frequencies. In normal-hearing animals, nearly a third of cortical neurons were sensitive to envelope-ITDs in response to SAM tones. In deaf animals with bilateral CI, the proportion of ITD-sensitive cortical neurons was approximately a fifth in response to SAM pulse trains. In normal-hearing and deaf animals with bilateral CI the proportion of ITD sensitive units and neural sensitivity to ITDs increased in response to HWR, compared with SAM stimuli. Consequently, novel stimulation strategies based on envelope enhancement may prove beneficial to individuals with bilateral cochlear implants.
Collapse
Affiliation(s)
- Douglas E. H. Hartley
- NIHR National Biomedical Research Unit in Hearing, Ropewalk House, Nottingham, United Kingdom
- Department of Otolaryngology, School of Clinical Sciences, Nottingham University, Nottingham, United Kingdom
- Medical Research Council Institute of Hearing Research, University Park, Nottingham, United Kingdom
- Department of Physiology, Anatomy & Genetics, University of Oxford, Oxford, United Kingdom
| | - Amal Isaiah
- Department of Physiology, Anatomy & Genetics, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
23
|
Fielden CA, Kluk K, McKay CM. Interpulse interval discrimination within and across channels: comparison of monopolar and tripolar mode of stimulation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 135:2913-2922. [PMID: 24815271 DOI: 10.1121/1.4869687] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Perception of temporal patterns is crucial to speech understanding and music perception in normal hearing, and is fundamental in the design and implementation of processing strategies for cochlear implants. Two experiments described here investigated the effect of stimulation mode (monopolar versus tripolar) on interpulse interval discrimination using single-electrode stimulation (experiment 1) and dual-electrode stimulation (experiment 2). Experiment 1 required participants to discriminate stimuli containing different interpulse intervals and experiment 2 required listeners to discriminate between two dual-electrode stimuli that had the same temporal pattern on each electrode, but differed in inter-electrode timing. The hypotheses were that (i) stimulation mode would affect the ability to distinguish interpulse interval patterns on a single electrode and (ii) the electrode separation range in which subjects were sensitive to inter-electrode timing would be more restricted in tripolar than in monopolar stimulation. Results in nine cochlear implant users showed that mode did not have a significant mean effect on either the ability to discriminate interpulse intervals in single-electrode stimulation or the range of electrode separation in dual-electrode stimulation in which participants were sensitive to inter-electrode timing. In conclusion, tripolar stimulation did not show any advantage in delivering temporal information within or across channels in this group.
Collapse
Affiliation(s)
- Claire A Fielden
- School of Psychological Sciences, Ellen Wilkinson Building, University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom
| | - Karolina Kluk
- School of Psychological Sciences, Ellen Wilkinson Building, University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom
| | - Colette M McKay
- School of Psychological Sciences, Ellen Wilkinson Building, University of Manchester, Oxford Road, Manchester M13 9PL, United Kingdom
| |
Collapse
|
24
|
Gordon KA, Wong DDE, Papsin BC. Bilateral input protects the cortex from unilaterally-driven reorganization in children who are deaf. Brain 2013; 136:1609-25. [PMID: 23576127 DOI: 10.1093/brain/awt052] [Citation(s) in RCA: 150] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Karen A Gordon
- Archie's Cochlear Implant Laboratory The Hospital for Sick Children Room 6D08, 555 University Avenue, Toronto, Ontario, Canada.
| | | | | |
Collapse
|
25
|
Abstracts of the British Society of Audiology annual conference (incorporating the Experimental and Clinical Short papers meetings). Int J Audiol 2013. [DOI: 10.3109/14992027.2013.765042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
26
|
Lin P, Lu T, Zeng FG. Central masking with bilateral cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 133:962-969. [PMID: 23363113 PMCID: PMC3574098 DOI: 10.1121/1.4773262] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2011] [Revised: 11/29/2012] [Accepted: 12/03/2012] [Indexed: 06/01/2023]
Abstract
Across bilateral cochlear implants, contralateral threshold shift has been investigated as a function of electrode difference between the masking and probe electrodes. For contralateral electric masking, maximum threshold elevations occurred when the position of the masker and probe electrode was approximately place-matched across ears. The amount of masking diminished with increasing masker-probe electrode separation. Place-dependent masking occurred in both sequentially implanted ears, and was not affected by the masker intensity or the time delay from the masker onset. When compared to previous contralateral masking results in normal hearing, the similarities between place-dependent central masking patterns suggest comparable mechanisms of overlapping excitation in the central auditory nervous system.
Collapse
Affiliation(s)
- Payton Lin
- Department of Biomedical Engineering, University of California, Irvine, California 92617, USA.
| | | | | |
Collapse
|
27
|
Schoenecker MC, Bonham BH, Stakhovskaya OA, Snyder RL, Leake PA. Monopolar intracochlear pulse trains selectively activate the inferior colliculus. J Assoc Res Otolaryngol 2012; 13:655-72. [PMID: 22722899 PMCID: PMC3441950 DOI: 10.1007/s10162-012-0333-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2011] [Accepted: 04/23/2012] [Indexed: 10/28/2022] Open
Abstract
Previous cochlear implant studies using isolated electrical stimulus pulses in animal models have reported that intracochlear monopolar stimulus configurations elicit broad extents of neuronal activation within the central auditory system-much broader than the activation patterns produced by bipolar electrode pairs or acoustic tones. However, psychophysical and speech reception studies that use sustained pulse trains do not show clear performance differences for monopolar versus bipolar configurations. To test whether monopolar intracochlear stimulation can produce selective activation of the inferior colliculus, we measured activation widths along the tonotopic axis of the inferior colliculus for acoustic tones and 1,000-pulse/s electrical pulse trains in guinea pigs and cats. Electrical pulse trains were presented using an array of 6-12 stimulating electrodes distributed longitudinally on a space-filling silicone carrier positioned in the scala tympani of the cochlea. We found that for monopolar, bipolar, and acoustic stimuli, activation widths were significantly narrower for sustained responses than for the transient response to the stimulus onset. Furthermore, monopolar and bipolar stimuli elicited similar activation widths when compared at stimulus levels that produced similar peak spike rates. Surprisingly, we found that in guinea pigs, monopolar and bipolar stimuli produced narrower sustained activation than 60 dB sound pressure level acoustic tones when compared at stimulus levels that produced similar peak spike rates. Therefore, we conclude that intracochlear electrical stimulation using monopolar pulse trains can produce activation patterns that are at least as selective as bipolar or acoustic stimulation.
Collapse
Affiliation(s)
- Matthew C. Schoenecker
- Department of Bioengineering, University of California San Francisco, San Francisco, CA 94143-0526 USA
| | - Ben H. Bonham
- Department of Otolaryngology–HNS, University of California San Francisco, San Francisco, CA 94143-0526 USA
| | - Olga A. Stakhovskaya
- Department of Hearing & Speech Sciences, University of Maryland at College Park, College Park, MD 94143-0526 USA
| | - Russell L. Snyder
- Department of Otolaryngology–HNS, University of California San Francisco, San Francisco, CA 94143-0526 USA
- Department of Psychology, Utah State University, Logan, UT 84322 USA
| | - Patricia A. Leake
- Department of Otolaryngology–HNS, University of California San Francisco, San Francisco, CA 94143-0526 USA
| |
Collapse
|
28
|
Relationships between electrically evoked potentials and loudness growth in bilateral cochlear implant users. Ear Hear 2012; 33:389-98. [PMID: 22246138 DOI: 10.1097/aud.0b013e318239adb8] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The goals of this study were (1) to describe the relationship between electrically evoked compound action potential (ECAP) and electrically evoked auditory brainstem response (EABR) amplitude growth functions and loudness growth functions in bilateral cochlear implant (CI) users, and (2) to determine whether matching the stimulus levels in the two ears of bilateral CI users based on equal ECAP amplitude, EABR amplitude, or current level resulted in the smallest discrepancy in loudness rating across the two ears. DESIGN Ten adult, bilateral CI users participated in this study. The stimulus used to elicit loudness judgments and generate ECAP and EABR growth functions was a train of biphasic current pulses (32 μs/phase) presented at a rate of 23 pps. Loudness growth functions were obtained with a method of constant stimuli. ECAPs were measured using the implant telemetry system. EABR growth functions were recorded using surface electrodes and standard averaging techniques. Both ears of each subject were tested. For each ear, ECAP, EABR, and loudness functions were recorded using both an apical and basal stimulating electrode. Both the physiologic and psychophysical growth functions were fit using linear regression techniques. RESULTS Comparison of the regression equations obtained for the two ears revealed that stimulus levels that yielded approximately equal ECAP amplitudes in the two ears were judged to differ in loudness, on average, by 20% for electrode 3 and 14% for electrode 13. Stimulation levels that evoked similar amplitude EABRs differed in loudness, on average, by 50% for electrode 3 and 13% for electrode 13. Matched stimulus current levels were judged to differ in loudness, on average, by 14% for electrode 3 and 16% for electrode 13. No significant differences in loudness discrepancy across ears derived from equal amplitude ECAP, EABR, or matched current levels were found. CONCLUSIONS This study demonstrated that stimuli that evoke equal amplitude neural responses in both ears of a bilateral CI user or which are matched in current level cannot be assumed to be perceived as equally loud. No statistically significant differences in accuracy were found between ECAP, EABR, or matched current levels or between the basal and apical electrode in approximations of equal loudness.
Collapse
|
29
|
Sheep as a large animal model for middle and inner ear implantable hearing devices: a feasibility study in cadavers. Otol Neurotol 2012; 33:481-9. [PMID: 22410732 DOI: 10.1097/mao.0b013e318248ee3a] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
OBJECTIVE Currently, no large animal model exists for surgical-experimental exploratory analysis of implantable hearing devices. In a histomorphometric study, we sought to investigate whether sheep or pig cochleae are suitable for this purpose and whether device implantation is feasible. METHODS Skulls of pig and sheep cadavers were examined using high-resolution 128-slice computed tomography (CT) to study anatomic relationships. A cochlear implant and an active middle ear implant could be successfully implanted into the sheep's inner and middle ear, respectively. Correct device placement was verified by CT and histology. The cochlear anatomy of the sheep was further studied by micro-CT and histology. RESULTS Our investigations indicate that the sheep is a suitable animal model for implantation of implantable hearing devices. The implantation of the devices was successfully performed by access through a mastoidectomy. The histologic, morphologic, and micro-CT study of the sheep cochlea showed that it is highly similar to the human cochlea. The temporal bone of the pig was not suitable for these microsurgical procedures because the middle and inner ear were not accessible owing to distinct soft and fatty tissue coverage of the mastoid. CONCLUSION The sheep is an appropriate large animal model for experimental studies with implantable hearing devices, whereas the pig is not.
Collapse
|
30
|
Binaural interactions develop in the auditory brainstem of children who are deaf: effects of place and level of bilateral electrical stimulation. J Neurosci 2012; 32:4212-23. [PMID: 22442083 DOI: 10.1523/jneurosci.5741-11.2012] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Bilateral cochlear implants (CIs) might promote development of binaural hearing required to localize sound sources and hear speech in noise for children who are deaf. These hearing skills improve in children implanted bilaterally but remain poorer than normal. We thus questioned whether the deaf and immature human auditory system is able to integrate input delivered from bilateral CIs. Using electrophysiological measures of brainstem activity that include the Binaural Difference (BD), a measure of binaural processing, we showed that a period of unilateral deprivation before bilateral CI use prolonged response latencies but that amplitudes were not significantly affected. Tonotopic organization was retained to some extent as evidenced by an elimination of the BD with large mismatches in place of stimulation between the two CIs. Smaller place mismatches did not affect BD latency or amplitude, indicating that the tonotopic organization of the auditory brainstem is underdeveloped and/or not well used by CI stimulation. Finally, BD amplitudes decreased when the intensity of bilateral stimulation became weighted to one side and this corresponded to a perceptual shift of sound away from midline toward the side of increased intensity. In summary, bilateral CI stimulation is processed by the developing human auditory brainstem leading to perceptual changes in sound location and potentially improving hearing for children who are deaf.
Collapse
|
31
|
Hancock KE, Chung Y, Delgutte B. Neural ITD coding with bilateral cochlear implants: effect of binaurally coherent jitter. J Neurophysiol 2012; 108:714-28. [PMID: 22592306 DOI: 10.1152/jn.00269.2012] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Poor sensitivity to the interaural time difference (ITD) constrains the ability of human bilateral cochlear implant users to listen in everyday noisy acoustic environments. ITD sensitivity to periodic pulse trains degrades sharply with increasing pulse rate but can be restored at high pulse rates by jittering the interpulse intervals in a binaurally coherent manner (Laback and Majdak. Binaural jitter improves interaural time-difference sensitivity of cochlear implantees at high pulse rates. Proc Natl Acad Sci USA 105: 814-817, 2008). We investigated the neural basis of the jitter effect by recording from single inferior colliculus (IC) neurons in bilaterally implanted, anesthetized cats. Neural responses to trains of biphasic pulses were measured as a function of pulse rate, jitter, and ITD. An effect of jitter on neural responses was most prominent for pulse rates above 300 pulses/s. High-rate periodic trains evoked only an onset response in most IC neurons, but introducing jitter increased ongoing firing rates in about half of these neurons. Neurons that had sustained responses to jittered high-rate pulse trains showed ITD tuning comparable with that produced by low-rate periodic pulse trains. Thus, jitter appears to improve neural ITD sensitivity by restoring sustained firing in many IC neurons. The effect of jitter on IC responses is qualitatively consistent with human psychophysics. Action potentials tended to occur reproducibly at sparse, preferred times across repeated presentations of high-rate jittered pulse trains. Spike triggered averaging of responses to jittered pulse trains revealed that firing was triggered by very short interpulse intervals. This suggests it may be possible to restore ITD sensitivity to periodic carriers by simply inserting short interpulse intervals at select times.
Collapse
Affiliation(s)
- Kenneth E Hancock
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear Infirmary, Boston, MA 02114, USA.
| | | | | |
Collapse
|
32
|
Preliminary results of the relationship between the binaural interaction component of the electrically evoked auditory brainstem response and interaural pitch comparisons in bilateral cochlear implant recipients. Ear Hear 2012; 33:57-68. [PMID: 21730858 DOI: 10.1097/aud.0b013e31822519ef] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE : The purpose of this study was to investigate the relationship between electrophysiologic measures of the binaural interaction component (BIC) of the electrically evoked auditory brainstem response and psychophysical measures of interaural pitch comparisons in Nucleus bilateral cochlear implant users. DESIGN : Data were collected for 10 postlingually deafened adult cochlear implant users. Each subject conducted an interaural pitch-comparison task using a biphasic pulse train with a pulse rate of 1000 pulses per second (pps) at high stimulation levels. Stimuli were presented in a two-interval, two-alternative forced-choice procedure with roving current variations. A subgroup of four subjects repeated the task at low stimulation levels. BICs were measured using loudness balanced, biphasic current pulses presented at a rate of 19.9 pps for each subject by pairing the electrode 12 (out of 22 intracochlear electrodes) in the right ear with each of 11 electrodes spaced across the electrode array in the left ear. The BIC was measured at high stimulation levels in 10 subjects and at low stimulation levels in 7 subjects. Because of differences in stimulation rate used in BIC measures and interaural pitch comparisons, the actual stimulation levels were different in these two measures. The relationship between BIC responses and results of interaural pitch comparisons was evaluated for each of the individual subjects and at the group level. Evaluation was carried out separately for results obtained at high and low stimulation levels. RESULTS : There was no significant correlation between results of BIC measures and interaural pitch comparisons on either the individual or group levels. Lower stimulation level did not improve the relationship between these two measures. CONCLUSIONS : No significant correlations between psychophysical measures of interaural pitch comparisons and electrophysiologic measures of the BIC of the electrically evoked auditory brainstem response were found. The lack of correlation may be attributed to methods used to quantify the data, small number of subjects retested at low stimulation levels, and central processing components involved in the interaural pitch-comparison task.
Collapse
|
33
|
Mc Laughlin M, Lu T, Dimitrijevic A, Zeng FG. Towards a closed-loop cochlear implant system: application of embedded monitoring of peripheral and central neural activity. IEEE Trans Neural Syst Rehabil Eng 2012; 20:443-54. [PMID: 22328183 DOI: 10.1109/tnsre.2012.2186982] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Although the cochlear implant (CI) is widely considered the most successful neural prosthesis, it is essentially an open-loop system that requires extensive initial fitting and frequent tuning to maintain a high, but not necessarily optimal, level of performance. Two developments in neuroscience and neuroengineering now make it feasible to design a closed-loop CI. One development is the recording and interpretation of evoked potentials (EPs) from the peripheral to the central nervous system. The other is the embedded hardware and software of a modern CI that allows recording of EPs. We review EPs that are pertinent to behavioral functions from simple signal detection and loudness growth to speech discrimination and recognition. We also describe signal processing algorithms used for electric artifact reduction and cancellation, critical to the recording of electric EPs. We then present a conceptual design for a closed-loop CI that utilizes in an innovative way the embedded implant receiver and stimulators to record short latency compound action potentials ( ~1 ms), auditory brainstem responses (1-10 ms) and mid-to-late cortical potentials (20-300 ms). We compare EPs recorded using the CI to EPs obtained using standard scalp electrodes recording techniques. Future applications and capabilities are discussed in terms of the development of a new generation of closed-loop CIs and other neural prostheses.
Collapse
Affiliation(s)
- Myles Mc Laughlin
- Department of Otolaryngology-Head and Neck Surgery, University of California, Irvine, CA 92697, USA.
| | | | | | | |
Collapse
|
34
|
Moreno LE, Rajguru SM, Matic AI, Yerram N, Robinson AM, Hwang M, Stock S, Richter CP. Infrared neural stimulation: beam path in the guinea pig cochlea. Hear Res 2011; 282:289-302. [PMID: 21763410 DOI: 10.1016/j.heares.2011.06.006] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2010] [Revised: 06/23/2011] [Accepted: 06/25/2011] [Indexed: 11/26/2022]
Abstract
It has been demonstrated that INS can be utilized to stimulate spiral ganglion cells in the cochlea. Although neural stimulation can be achieved without direct contact of the radiation source and the tissue, the presence of fluids or bone between the target structure and the radiation source may lead to absorption or scattering of the radiation, which may limit the efficacy of INS. The present study demonstrates the neural structures in the radiation beam path that can be stimulated. Histological reconstructions and microCT of guinea pig cochleae stimulated with an infrared laser suggest that the orientation of the beam from the optical fiber determined the site of stimulation in the cochlea. Best frequencies of the INS-evoked neural responses obtained from the central nucleus of the inferior colliculus matched the histological sites in the spiral ganglion.
Collapse
Affiliation(s)
- Laura E Moreno
- Department of Otolaryngology, Northwestern University, Feinberg School of Medicine, Chicago, IL, USA
| | | | | | | | | | | | | | | |
Collapse
|
35
|
|
36
|
Neural coding of interaural time differences with bilateral cochlear implants: effects of congenital deafness. J Neurosci 2010; 30:14068-79. [PMID: 20962228 DOI: 10.1523/jneurosci.3213-10.2010] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Human bilateral cochlear implant users do poorly on tasks involving interaural time differences (ITD), a cue that provides important benefits to the normal hearing, especially in challenging acoustic environments, yet the precision of neural ITD coding in acutely deafened, bilaterally implanted cats is essentially normal (Smith and Delgutte, 2007a). One explanation for this discrepancy is that the extended periods of binaural deprivation typically experienced by cochlear implant users degrades neural ITD sensitivity, by either impeding normal maturation of the neural circuitry or altering it later in life. To test this hypothesis, we recorded from single units in inferior colliculus of two groups of bilaterally implanted, anesthetized cats that contrast maximally in binaural experience: acutely deafened cats, which had normal binaural hearing until experimentation, and congenitally deaf white cats, which received no auditory inputs until the experiment. Rate responses of only half as many neurons showed significant ITD sensitivity to low-rate pulse trains in congenitally deaf cats compared with acutely deafened cats. For neurons that were ITD sensitive, ITD tuning was broader and best ITDs were more variable in congenitally deaf cats, leading to poorer ITD coding within the naturally occurring range. A signal detection model constrained by the observed physiology supports the idea that the degraded neural ITD coding resulting from deprivation of binaural experience contributes to poor ITD discrimination by human implantees.
Collapse
|
37
|
Effects of stimulation level and electrode pairing on the binaural interaction component of the electrically evoked auditory brain stem response. Ear Hear 2010; 31:457-70. [PMID: 20418771 DOI: 10.1097/aud.0b013e3181d5d9bf] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The purpose of this study was to investigate the effects of stimulation level and electrode pairing on the binaural interaction component (BIC) of the electrically evoked auditory brain stem response (EABR) in Nucleus cochlear implant (CI) users. DESIGN Ten postlingually deafened adult CI users participated in this study. EABRs were measured using loudness balanced, biphasic current pulses presented in the left monaural, right monaural, and bilateral stimulation conditions. BICs were computed based on measures of the EABR obtained for each subject by pairing the electrode 12 (of 22 intracochlear electrodes) in the right ear with each of 11 electrodes spaced across the electrode array in the left ear. The effect of stimulation level on the amplitude of the BIC was investigated by measuring growth functions of the BIC from six subjects. The effect of electrode pairing on the amplitude of the BIC was studied at high stimulation levels in 10 subjects and at low stimulation levels in seven subjects. The high stimulation level was chosen as the 90% point of the subject's dynamic range (DR) or the highest stimulation level in which the electrophysiologic recordings were not contaminated by muscle artifacts. The low stimulation level was chosen as a level that was 10% point of subject's DR higher than the BIC threshold for six of these seven subjects. For one subject, BIC thresholds were not available and the low stimulation level was referred to the 70% point of subject's DR. RESULTS BICs were successfully recorded from all 11 interaural electrode pairs for a majority of subjects tested at both stimulation levels. BIC amplitudes increased with stimulation level. The effect of stimulation level on latencies of the BIC was less robust. At high stimulation levels, BIC amplitudes did not change significantly as the stimulating electrode used in the left ear was systematically varied. When low stimulation levels were used, BIC amplitude was maximal for interaural electrode pairs with similar intracochlear positions and decreased when the offset between interaural electrodes increased. CONCLUSIONS This study demonstrates that stimulation level affects amplitudes of the BIC response. It is possible to record the BIC of the EABR in bilateral CI users even from interaural electrode pairs that have large interaural offsets. This finding suggests that when high-level stimuli are used, there is a broad pattern of current spread within the two cochleae. At lower stimulation levels, the spread of excitation within the cochlea is reduced making the effect of electrode pairing on the amplitude of the BIC more pronounced.
Collapse
|
38
|
Siciliano CM, Faulkner A, Rosen S, Mair K. Resistance to learning binaurally mismatched frequency-to-place maps: implications for bilateral stimulation with cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2010; 127:1645-60. [PMID: 20329863 DOI: 10.1121/1.3293002] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Simulations of monaural cochlear implants in normal hearing listeners have shown that the deleterious effects of upward spectral shifting on speech perception can be overcome with training. This study simulates bilateral stimulation with a unilateral spectral shift to investigate whether listeners can adapt to upward-shifted speech information presented together with contralateral unshifted information. A six-channel, dichotic, interleaved sine-carrier vocoder simulated a binaurally mismatched frequency-to-place map. Odd channels were presented to one ear with an upward frequency shift equivalent to 6 mm on the basilar membrane, while even channels were presented to the contralateral ear unshifted. In Experiment 1, listeners were trained for 5.3 h with either the binaurally mismatched processor or with just the shifted monaural bands. In Experiment 2, the duration of training was 10 h, and the trained condition alternated between those of Experiment 1. While listeners showed learning in both experiments, intelligibility with the binaurally mismatched processor never exceeded, intelligibility with just the three unshifted bands, suggesting that listeners did not benefit from combining the mismatched maps, even though there was clear scope to do so. Frequency-place map alignment may thus be of importance when optimizing bilateral devices of the type studied here.
Collapse
Affiliation(s)
- Catherine M Siciliano
- Speech, Hearing and Phonetic Sciences, Division of Psychology and Language Sciences, UCL, Chandler House, 2 Wakefield Street, London WC1N 1PF, United Kingdom.
| | | | | | | |
Collapse
|
39
|
Poon BB, Eddington DK, Noel V, Colburn HS. Sensitivity to interaural time difference with bilateral cochlear implants: Development over time and effect of interaural electrode spacing. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2009; 126:806-15. [PMID: 19640045 PMCID: PMC2730718 DOI: 10.1121/1.3158821] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Sensitivity to interaural time difference (ITD) in constant-amplitude pulse trains was measured in four sequentially implanted bilateral cochlear implant (CI) subjects. The sensitivity measurements were made as a function of time beginning directly after the second ear was implanted, continued for periods of months before subjects began wearing bilateral sound processors, and extended for months while the subjects used bilateral sound processors in day-to-day listening. Measurements were also made as a function of the relative position of the left/right electrodes. The two subjects with the shortest duration of binaural deprivation before implantation demonstrated ITD sensitivity soon after second-ear implantation (before receiving the second sound processor), while the other two did not demonstrate sensitivity until after months of daily experience using bilateral processors. The interaural mismatch in electrode position required to decrease ITD sensitivity by a factor of 2 (half-width) for CI subjects was five times greater than the half-width for interaural carrier-frequency disparity in normal-hearing subjects listening to sinusoidally amplitude-modulated high-frequency tones. This large half-width is likely to contribute to poor binaural performance in CI users, especially in environments with multiple broadband sound sources.
Collapse
Affiliation(s)
- Becky B Poon
- Cochlear Implant Research Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA 02114, USA
| | | | | | | |
Collapse
|
40
|
Miller CA, Brown CJ, Abbas PJ, Chi SL. The clinical application of potentials evoked from the peripheral auditory system. Hear Res 2008; 242:184-97. [DOI: 10.1016/j.heares.2008.04.005] [Citation(s) in RCA: 82] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2007] [Revised: 04/02/2008] [Accepted: 04/14/2008] [Indexed: 11/27/2022]
|
41
|
Gordon KA, Valero J, van Hoesel R, Papsin BC. Abnormal Timing Delays in Auditory Brainstem Responses Evoked by Bilateral Cochlear Implant Use in Children. Otol Neurotol 2008; 29:193-8. [DOI: 10.1097/mao.0b013e318162514c] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
42
|
Abstract
PURPOSE OF REVIEW Although unilateral cochlear implantation generally provides good speech understanding under quiet conditions, cochlear implantation patients frequently report difficulty understanding speech when exposed to background noise and with sound localization. Since these two listening functions require binaural stimulation for normal individuals and hearing aid recipients, it is not surprising that there is growing interest in binaural implants. This update reviews the basics of binaural listening and the advantages and disadvantages of binaural cochlear implantation. RECENT FINDINGS Although the psychoacoustic literature has long demonstrated the benefits of binaural hearing, only recently have studies shown improvement in speech intelligibility with bilateral implants compared with unilateral implants. Of the three known binaural mechanisms, the head shadow effect provides greater benefit than binaural squelch or summation. In addition, binaural cochlear implants improve the ability to localize sound. SUMMARY Bilateral implantation provides multiple benefits to patients with severe to profound hearing loss. Research is currently directed at improving speech intelligibility by utilizing evolving technologies in speech-processing strategies.
Collapse
Affiliation(s)
- Kevin D Brown
- Department of Otolaryngology, University of Miami Ear Institute, Miami, Florida 33101, USA
| | | |
Collapse
|
43
|
Gordon KA, Valero J, Papsin BC. Auditory brainstem activity in children with 9–30 months of bilateral cochlear implant use. Hear Res 2007; 233:97-107. [PMID: 17850999 DOI: 10.1016/j.heares.2007.08.001] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2007] [Revised: 07/29/2007] [Accepted: 08/01/2007] [Indexed: 10/23/2022]
Abstract
Bilateral cochlear implants aim to restore binaural processing along the auditory pathways in children with bilateral deafness. We assessed auditory brainstem activity evoked by single biphasic pulses delivered by an apical or basal electrode from the left, right and both cochlear implants in 13 children. Repeated measures were made over the first 9-30 months of bilateral implant use. In children with short or long periods of unilateral implant use prior to the second implantation, Wave eV of the auditory brainstem response was initially prolonged when evoked by the naïve versus experienced side. These differences tended to resolve in children first implanted <3 years of age but not in children implanted at older ages with long delays between implants. Latency differences were projected to persist for longer periods in children with long delays between implants compared with children with short delays. No differences in right versus left evoked eV latency were found in 2 children receiving bilateral implants simultaneously and their response latencies decreased over time. Binaural interaction responses showed effects of stimulating electrode position (responses were more detectable when evoked by an apical than basal pair of implant electrodes), and duration of delay between implants (measured by latency delays). The trends shown here suggest a negative impact of unilateral implant use on bilateral auditory brainstem plasticity.
Collapse
Affiliation(s)
- K A Gordon
- Cochlear Implant Laboratory, The Hospital for Sick Children, Room 6D08, 555 University Avenue, Toronto, ON, Canada M5G 1X8.
| | | | | |
Collapse
|
44
|
Affiliation(s)
- W Delb
- Klinik und Poliklinik für Hals- Nasen-Ohren-Heilkunde, Universitätskliniken des Saarlandes, Homburg/Saar, Deutschland.
| |
Collapse
|
45
|
Abstract
Binaural auditory brainstem processing was examined using evoked potential measures in 40 children who were implanted early and received a second implant simultaneously or after long or short periods of unilateral implant use. Wave latencies were shorter when evoked by the experienced versus naïve implanted ear at initial bilateral activation. Binaural difference waves were detected in most children in response to apical but not basal electrode stimulation and were prolonged in latency in children implanted after long or short delays between implants. Timing differences between the implanted ears in children receiving sequential but not simultaneous bilateral implants reflect a relative immaturity of pathways innervating the second ear and results in abnormal timing of binaural processing at this initial implant stage.
Collapse
Affiliation(s)
- Karen A Gordon
- The Hospital for Sick Children, Toronto, Ontario, Canada.
| | | | | |
Collapse
|