1
|
Dufva M. A quantitative meta-analysis comparing cell models in perfused organ on a chip with static cell cultures. Sci Rep 2023; 13:8233. [PMID: 37217582 DOI: 10.1038/s41598-023-35043-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Accepted: 05/11/2023] [Indexed: 05/24/2023] Open
Abstract
As many consider organ on a chip for better in vitro models, it is timely to extract quantitative data from the literature to compare responses of cells under flow in chips to corresponding static incubations. Of 2828 screened articles, 464 articles described flow for cell culture and 146 contained correct controls and quantified data. Analysis of 1718 ratios between biomarkers measured in cells under flow and static cultures showed that the in all cell types, many biomarkers were unregulated by flow and only some specific biomarkers responded strongly to flow. Biomarkers in cells from the blood vessels walls, the intestine, tumours, pancreatic island, and the liver reacted most strongly to flow. Only 26 biomarkers were analysed in at least two different articles for a given cell type. Of these, the CYP3A4 activity in CaCo2 cells and PXR mRNA levels in hepatocytes were induced more than two-fold by flow. Furthermore, the reproducibility between articles was low as 52 of 95 articles did not show the same response to flow for a given biomarker. Flow showed overall very little improvements in 2D cultures but a slight improvement in 3D cultures suggesting that high density cell culture may benefit from flow. In conclusion, the gains of perfusion are relatively modest, larger gains are linked to specific biomarkers in certain cell types.
Collapse
Affiliation(s)
- Martin Dufva
- Department of Health Technology, Technical University of Denmark, 2800, Kgs Lyngby, Denmark.
| |
Collapse
|
2
|
Lim S, Kim SW, Kim IK, Song BW, Lee S. Organ-on-a-chip: Its use in cardiovascular research. Clin Hemorheol Microcirc 2022; 83:315-339. [DOI: 10.3233/ch-221428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Organ-on-a-chip (OOAC) has attracted great attention during the last decade as a revolutionary alternative to conventional animal models. This cutting-edge technology has also brought constructive changes to the field of cardiovascular research. The cardiovascular system, especially the heart as a well-protected vital organ, is virtually impossible to replicate in vitro with conventional approaches. This made scientists assume that they needed to use animal models for cardiovascular research. However, the frequent failure of animal models to correctly reflect the native cardiovascular system necessitated a search for alternative platforms for preclinical studies. Hence, as a promising alternative to conventional animal models, OOAC technology is being actively developed and tested in a wide range of biomedical fields, including cardiovascular research. Therefore, in this review, the current literature on the use of OOACs for cardiovascular research is presented with a focus on the basis for using OOACs, and what has been specifically achieved by using OOACs is also discussed. By providing an overview of the current status of OOACs in cardiovascular research and its future perspectives, we hope that this review can help to develop better and optimized research strategies for cardiovascular diseases (CVDs) as well as identify novel applications of OOACs in the near future.
Collapse
Affiliation(s)
- Soyeon Lim
- Institute for Bio-Medical Convergence, College of Medicine, Catholic Kwandong University, Gangneung, Gangwon-do, Republic of Korea
| | - Sang Woo Kim
- Institute for Bio-Medical Convergence, College of Medicine, Catholic Kwandong University, Gangneung, Gangwon-do, Republic of Korea
| | - Il-Kwon Kim
- Institute for Bio-Medical Convergence, College of Medicine, Catholic Kwandong University, Gangneung, Gangwon-do, Republic of Korea
| | - Byeong-Wook Song
- Institute for Bio-Medical Convergence, College of Medicine, Catholic Kwandong University, Gangneung, Gangwon-do, Republic of Korea
| | - Seahyoung Lee
- Institute for Bio-Medical Convergence, College of Medicine, Catholic Kwandong University, Gangneung, Gangwon-do, Republic of Korea
| |
Collapse
|
3
|
Wang X, Kuban-Johnston D, Lapuerta P, Lacerda CMR. Telotristat ethyl reverses myxomatous changes in mice mitral valves. Front Cardiovasc Med 2022; 9:945672. [PMID: 35990981 PMCID: PMC9386075 DOI: 10.3389/fcvm.2022.945672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 07/06/2022] [Indexed: 11/29/2022] Open
Abstract
Rationale Myxomatous mitral valve degeneration is a common pathological manifestation of mitral valve regurgitation, with or without valvular prolapse. In addition to similarities between naturally occurring and serotonergic valve degeneration, an increasing body of evidence has recently suggested that serotonin signaling is a regulator of degenerative valvulopathies. Studies have found that serotonin can be synthesized locally by valvular cells and serotonin receptors in turn may be activated to promote signaling. Recently, telotristat ethyl (TE) has been introduced as a treatment for carcinoid disease, by selectively inhibiting tryptophan hydroxylase 1, the rate-limiting enzyme in peripheral serotonin synthesis. TE provides a unique tool to test inhibition of serotonin synthesis in vivo, without impacting brain serotonin, to further confirm the role of local serotonin synthesis on heart valves. Objective To confirm the link between serotonin and myxomatous valvular disease in vivo. Methods and results A hypertension-induced myxomatous mitral valve disease mouse model was employed to test the effect of TE on valvular degeneration. Circulating serotonin and local serotonin in valve tissues were tested by enzyme immunoassay and immunohistochemistry, respectively. TE was administrated in two modes: (1) parallel with angiotensin II (A2); (2) post A2 treatment. Myxomatous changes were successfully recapitulated in hypertensive mice, as determined by ECM remodeling, myofibroblast transformation, and serotonin signaling activation. These changes were at least partially reversed upon TE administration. Conclusion This study provides the first evidence of TE as a potential therapeutic for myxomatous mitral disease, either used to prevent or reverse myxomatous degeneration.
Collapse
Affiliation(s)
- Xinmei Wang
- Department of Bioengineering, Shenyang University, Shenyang, China
| | | | - Pablo Lapuerta
- Lexicon Pharmaceuticals, Basking Ridge, NJ, United States
| | - Carla M. R. Lacerda
- Department of Chemical Engineering, The University of Texas at Tyler, Tyler, TX, United States
| |
Collapse
|
4
|
circ-CCND1 regulates the CCND1/P53/P21 pathway through sponging miR-138-5p in valve interstitial cells to aggravate aortic valve calcification. J Physiol Biochem 2022; 78:845-854. [PMID: 35776289 DOI: 10.1007/s13105-022-00907-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 06/20/2022] [Indexed: 10/17/2022]
Abstract
To discuss the effect and mechanism of circular-CCND1 (circ-CCND1) on the regulation of calcified aortic valve disease (CAVD). Differentially expressed circRNAs were screened through the GSE155119 data set and biological prediction. Subsequently, the miR-138-5p, CCND1, and circ-CCND1 expression were detected in the non-calcified and calcified aortic valve. Then Pearson correlation analysis was performed to analyze the correlation between the above expression, and dual luciferase and RNA-pull down assays for verifying the target relationship. Porcine aortic valve interstitial cells (AVICs) were isolated and transfected with pcDNA-circ-CCND1, miR-138-5p inhibitor, and miR-138-5p mimics. The alkaline phosphatase (ALP) activity was quantitatively analyzed by ALP staining, and alizarin-red staining was to check the calcium nodules formation. Finally, Western blot was applied to detect the expression of proteins associated with osteogenic differentiation (Runx2, Osterix, OPN) and CCND1/P53/P21 pathway proteins. Circ-CCND1 was highly expressed in calcific aortic valves. After inhibiting circ-CCND1 expression, a significant reduction was shown in ALP activity, the degree of ossification and the formation of calcium nodules in AVICs, and osteogenic differentiation-related protein expression and CCND1/P53/P21 pathway protein expression. By contrast, inhibition of miR-138-5p and circ-CCND1 together promoted the calcification of AVICs and expression of CCND1/P53/P21 pathway proteins. P53 inhibitor (PFT-α) could significantly reduce activation of CCND1/P53/P21 pathway protein expression by circ-CCND1 overexpression. However, P53 activator (Nutlin-3) significantly restored the suppression of the above pathway-related protein expression by downregulation of circ-CCND1. Circ-CCND1 sponges miR-138-5p to regulate CCND1 expression, thereby promoting the calcification of AVICs.
Collapse
|
5
|
Organ-on-a-Chip: Design and Simulation of Various Microfluidic Channel Geometries for the Influence of Fluid Dynamic Parameters. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12083829] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Shear stress, pressure, and flow rate are fluid dynamic parameters that can lead to changes in the morphology, proliferation, function, and survival of many cell types and have a determinant impact on tissue function and viability. Microfluidic devices are promising tools to investigate these parameters and fluid behaviour within different microchannel geometries. This study discusses and analyses different designed microfluidic channel geometries regarding the influence of fluid dynamic parameters on their microenvironment at specified fluidic parameters. The results demonstrate that in the circular microchamber, the velocity and shear stress profiles assume a parabolic shape with a maximum velocity occurring in the centre of the chamber and a minimum velocity at the walls. The longitudinal microchannel shows a uniform velocity and shear stress profile throughout the microchannel. Simulation studies for the two geometries with three parallel microchannels showed that in proximity to the micropillars, the velocity and shear stress profiles decreased. Moreover, the pressure is inversely proportional to the width and directly proportional to the flow rate within the microfluidic channels. The simulations showed that the velocity and wall shear stress indicated different values at different flow rates. It was also found that the width and height of the microfluidic channels could affect both velocity and shear stress profiles, contributing to the control of shear stress. The study has demonstrated strategies to predict and control the effects of these forces and the potential as an alternative to conventional cell culture as well as to recapitulate the cell- and organ-specific microenvironment.
Collapse
|
6
|
Mendoza M, Chen MH, Huang P, Mahler GJ. Shear and endothelial induced late-stage calcific aortic valve disease-on-a-chip develops calcium phosphate mineralizations. LAB ON A CHIP 2022; 22:1374-1385. [PMID: 35234762 DOI: 10.1039/d1lc00931a] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Calcific aortic valve disease (CAVD) is an active pathobiological process leading to severe aortic stenosis, where the only treatment is valve replacement. Late-stage CAVD is characterized by calcification, disorganization of collagen, and deposition of glycosaminoglycans, such as chondroitin sulfate (CS), in the fibrosa. We developed a three-dimensional microfluidic device of the aortic valve fibrosa to study the effects of shear stress (1 or 20 dyne per cm2), CS (1 or 20 mg mL-1), and endothelial cell presence on calcification. CAVD chips consisted of a collagen I hydrogel, where porcine aortic valve interstitial cells were embedded within and porcine aortic valve endothelial cells were seeded on top of the matrix for up to 21 days. Here, we show that this CAVD-on-a-chip is the first to develop human-like calcified nodules varying in calcium phosphate mineralization maturity resulting from high shear and endothelial cells, specifically di- and octa-calcium phosphates. Long-term co-culture microfluidic studies confirmed cell viability and calcium phosphate formations throughout 21 days. Given that CAVD has no targeted therapies, the creation of a physiologically relevant test-bed of the aortic valve could lead to advances in preclinical studies.
Collapse
Affiliation(s)
- Melissa Mendoza
- Department of Biomedical Engineering, Binghamton University, P.O Box 6000, Binghamton, NY, 13902, USA.
| | - Mei-Hsiu Chen
- Department of Mathematical Sciences, Binghamton University, Binghamton, NY, 13902, USA
| | - Peter Huang
- Department of Mechanical Engineering, Binghamton University, Binghamton, NY, 13902, USA
| | - Gretchen J Mahler
- Department of Biomedical Engineering, Binghamton University, P.O Box 6000, Binghamton, NY, 13902, USA.
| |
Collapse
|
7
|
Tandon I, Ozkizilcik A, Ravishankar P, Balachandran K. Aortic valve cell microenvironment: Considerations for developing a valve-on-chip. BIOPHYSICS REVIEWS 2021; 2:041303. [PMID: 38504720 PMCID: PMC10903420 DOI: 10.1063/5.0063608] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 11/15/2021] [Indexed: 03/21/2024]
Abstract
Cardiac valves are sophisticated, dynamic structures residing in a complex mechanical and hemodynamic environment. Cardiac valve disease is an active and progressive disease resulting in severe socioeconomic burden, especially in the elderly. Valve disease also leads to a 50% increase in the possibility of associated cardiovascular events. Yet, valve replacement remains the standard of treatment with early detection, mitigation, and alternate therapeutic strategies still lacking. Effective study models are required to further elucidate disease mechanisms and diagnostic and therapeutic strategies. Organ-on-chip models offer a unique and powerful environment that incorporates the ease and reproducibility of in vitro systems along with the complexity and physiological recapitulation of the in vivo system. The key to developing effective valve-on-chip models is maintaining the cell and tissue-level microenvironment relevant to the study application. This review outlines the various components and factors that comprise and/or affect the cell microenvironment that ought to be considered while constructing a valve-on-chip model. This review also dives into the advancements made toward constructing valve-on-chip models with a specific focus on the aortic valve, that is, in vitro studies incorporating three-dimensional co-culture models that incorporate relevant extracellular matrices and mechanical and hemodynamic cues.
Collapse
Affiliation(s)
- Ishita Tandon
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, Arkansas 72701, USA
| | - Asya Ozkizilcik
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, Arkansas 72701, USA
| | - Prashanth Ravishankar
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, Arkansas 72701, USA
| | - Kartik Balachandran
- Department of Biomedical Engineering, University of Arkansas, Fayetteville, Arkansas 72701, USA
| |
Collapse
|
8
|
Wang X, Deb N, Lacerda CMR. Comparison of Serotonin-Regulated Calcific Processes in Aortic and Mitral Valvular Interstitial Cells. ACS OMEGA 2021; 6:19494-19505. [PMID: 34368536 PMCID: PMC8340088 DOI: 10.1021/acsomega.1c01723] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 06/28/2021] [Indexed: 06/13/2023]
Abstract
Calcification is an important pathological process and a common complication of degenerative valvular heart diseases, with higher incidence in aortic versus mitral valves. Two phenotypes of valvular interstitial cells (VICs), activated VICs and osteoblastic VICs (obVICs), synergistically orchestrate this pathology. It has been demonstrated that serotonin is involved in early stages of myxomatous mitral degeneration, whereas the role of serotonin in calcific aortic valve disease is still unknown. To uncover the link between serotonin and osteogenesis in heart valves, osteogenesis of aortic and mitral VICs was induced in vitro. Actin polymerization and serotonin signaling were inhibited using cytochalasin D and serotonin inhibitors, respectively, to investigate the role of cell activation and serotonin signals in valvular cell osteogenesis. To evaluate calcification progress, calcium and collagen deposits along with the expression of protein markers, including the rate-limiting enzyme of serotonin synthesis [tryptophan hydroxylase 1 (TPH1)], were assessed. When exposed to osteogenic culture conditions and grown on soft surfaces, passage zero aortic VICs increased extracellular collagen deposits and obVIC phenotype markers. A more intense osteogenic process was observed in aortic VICs of higher passages, where cells were activated prior to osteogenic induction. For both, TPH1 expression was upregulated as osteogenesis advanced. However, these osteogenic changes were reversed upon serotonin inhibition. This discovery provides a better understanding of signaling pathways regulating VIC phenotype transformation and explains different manifestations of degenerative pathologies. In addition, the discovery of serotonin-based inhibition of valvular calcification will contribute to the development of potential novel therapies for calcific valvular diseases.
Collapse
Affiliation(s)
- Xinmei Wang
- Department
of Bioengineering, Shenyang University, Shenyang, Liaoning 110044, China
| | - Nandini Deb
- Department
of Chemical Engineering, Texas Tech University, Lubbock, Texas 79409-3121, United States
| | - Carla M. R. Lacerda
- Department
of Chemical Engineering, Texas Tech University, Lubbock, Texas 79409-3121, United States
| |
Collapse
|
9
|
Driscoll K, Cruz AD, Butcher JT. Inflammatory and Biomechanical Drivers of Endothelial-Interstitial Interactions in Calcific Aortic Valve Disease. Circ Res 2021; 128:1344-1370. [PMID: 33914601 DOI: 10.1161/circresaha.121.318011] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Calcific aortic valve disease is dramatically increasing in global burden, yet no therapy exists outside of prosthetic replacement. The increasing proportion of younger and more active patients mandates alternative therapies. Studies suggest a window of opportunity for biologically based diagnostics and therapeutics to alleviate or delay calcific aortic valve disease progression. Advancement, however, has been hampered by limited understanding of the complex mechanisms driving calcific aortic valve disease initiation and progression towards clinically relevant interventions.
Collapse
Affiliation(s)
| | - Alexander D Cruz
- Meinig School of Biomedical Engineering, Cornell University, Ithaca NY
| | | |
Collapse
|
10
|
Gao B, Kang Y, Zhang Q, Chang Y. Biomechanical effects of the novel series LVAD on the aortic valve. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 197:105763. [PMID: 32998103 DOI: 10.1016/j.cmpb.2020.105763] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Accepted: 09/14/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND AND OBJECTIVE The series type of LVAD (i.e., BJUT-II VAD) is a novel left ventricular assist device, whose effects on the aortic valve remain unclear. METHODS The biomechanical effects of BJUT-II VAD on the aortic valve were investigated by using a fluid-structure interaction method. The geometric model of BJUT-II VAD was virtually implanted into the ascending aorta to generate the realistic flow pattern for the aortic valve (i.e., support). In addition, the biomechanical states of the aortic valve without BJUT-II VAD support was computed as control (i.e., control case). RESULTS Results demonstrated that the biomechanical effects of BJUT-II VAD were quite different from that resulting from traditional "bypass LVAD." Compared with those in the control case, BJUT-II VAD support could significantly reduce the stress load of the leaflet (maximum stress, 0.5 MPa in the control case vs. 0.12 MPa in the support case). Similarly, the rapid valve opening time (100 ms in the control case vs. 175 ms in the support case) and rapid valve closing time (50 ms in the control case vs. 150 ms in the support case) in the support case were obviously longer than those in the control case. Moreover, BJUT-II VAD support reduced retrograde blood flow during the diastolic phase and significantly changed the distribution of WSS of the leaflets. CONCLUSIONS In summary, while unloading the left ventricle, BJUT-II VAD could provide beneficial biomechanical states for the aortic leaflets, thereby reducing the risk of aortic valve disease.
Collapse
Affiliation(s)
- Bin Gao
- School of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, PR China.
| | - Yizhou Kang
- School of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, PR China
| | - Qi Zhang
- National Energy Conservation Center, Beijing, PR China
| | - Yu Chang
- School of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, PR China
| |
Collapse
|
11
|
Teng P, Xu X, Ni C, Yan H, Sun Q, Zhang E, Ni Y. Identification of key genes in calcific aortic valve disease by integrated bioinformatics analysis. Medicine (Baltimore) 2020; 99:e21286. [PMID: 32702920 PMCID: PMC7373610 DOI: 10.1097/md.0000000000021286] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Calcific aortic valve disease (CAVD) is highly prevalent in our aging world and has no effective pharmaceutical treatment. Intense efforts have been made but the underlying molecular mechanisms of CAVD are still unclear.This study was designed to identify the critical genes and pathways in CAVD by bioinformatics analysis. Microarray datasets of GSE12644, GSE51472, and GSE83453 were obtained from Gene Expression Omnibus database. Differentially expressed genes (DEGs) were identified and functional and pathway enrichment analysis was performed. Subsequently, the protein-protein interaction network (PPI) was constructed with Search Tool for the Retrieval of Interacting Genes and was visualized with Cytoscape to identify the most significant module. Hub genes were identified by Cytoscape plugin cytoHubba.A total of 179 DEGs, including 101 upregulated genes and 78 downregulated genes, were identified. The enriched functions and pathways of the DEGs include inflammatory and immune response, chemotaxis, extracellular matrix (ECM) organization, complement and coagulation cascades, ECM receptor interaction, and focal adhesion. The most significant module in the PPI network was analyzed and genes among it were mainly enriched in chemotaxis, locomotory behavior, immune response, chemokine signaling pathway, and extracellular space. In addition, DEGs, with degrees ≥ 10 and the top 10 highest Maximal Chique Centrality (MCC) score, were identified as hub genes. CCR1, MMP9, VCAM1, and ITGAX, which were of the highest degree or MCC score, were manually reviewed.The DEGs and hub genes identified in the present study help us understand the molecular mechanisms underlying the pathogenesis of CAVD and might serve as candidate therapeutic targets for CAVD.
Collapse
Affiliation(s)
- Peng Teng
- Department of Cardiothoracic Surgery
| | | | | | - Haimeng Yan
- Department of Bone Marrow Transplantation Center
| | - Qianhui Sun
- Department of Surgical Intensive Care Unit, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, P.R. China
| | - Enfan Zhang
- Department of Bone Marrow Transplantation Center
| | - Yiming Ni
- Department of Cardiothoracic Surgery
| |
Collapse
|
12
|
Wang X, Ali MS, Lacerda CMR. Osteogenesis inducers promote distinct biological responses in aortic and mitral valve interstitial cells. J Cell Biochem 2019; 120:11158-11171. [PMID: 30746757 DOI: 10.1002/jcb.28392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 12/27/2018] [Accepted: 01/09/2019] [Indexed: 01/24/2023]
Abstract
Both aortic and mitral valves calcify in pathological conditions; however, the prevalence of aortic valve calcification is high whereas mitral valve leaflet calcification is somewhat rare. Patterns of valvular calcification may differ due to valvular architecture, but little is known to that effect. In this study, we investigated the intrinsic osteogenic differentiation potential of aortic versus mitral valve interstitial cells provided minimal differentiation conditions. For the assessment of calcification at the cellular level, we used classic inducers of osteogenesis in stem cells: β-glycerophosphate (β-Gly), dexamethasone (Dex), and ascorbate (Asc). In addition to proteomic analyses, osteogenic markers and calcium precipitates were evaluated across treatments of aortic and mitral valve cells. The combination of β-Gly, Asc, and Dex induced aortic valve interstitial cells to synthesize extracellular matrix, overexpress osteoblastic markers, and deposit calcium. However, no strong evidence showed the calcification of mitral valve interstitial cells. Mitral cells mainly responded to Asc and Dex by cell activation. These findings provide a deeper understanding of the physiological properties of aortic and mitral valves and tendencies for calcific changes within each valve type, contributing to the development of future therapeutics for heart valve diseases.
Collapse
Affiliation(s)
- Xinmei Wang
- Department of Chemical Engineering, Texas Tech University, Lubbock, Texas
| | - Mir S Ali
- Department of Chemical Engineering, Texas Tech University, Lubbock, Texas
| | - Carla M R Lacerda
- Department of Chemical Engineering, Texas Tech University, Lubbock, Texas
| |
Collapse
|
13
|
Agarwal T, Narayana GH, Banerjee I. Keratinocytes are mechanoresponsive to the microflow-induced shear stress. Cytoskeleton (Hoboken) 2019; 76:209-218. [PMID: 30969461 DOI: 10.1002/cm.21521] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2018] [Revised: 02/27/2019] [Accepted: 04/04/2019] [Indexed: 12/11/2022]
Abstract
Here, we have reported that keratinocytes respond to the microflow-induced shear stress both at the collective and individual cell level. Using a microfluidic setup, we categorically showed that low shear stress of magnitude 0.06 dyne/cm2 could induce morphological variation and cytoskeletal reorganization in keratinocyte, whereas higher shear stress (6 dyne/cm2 ) resulted in cellular disruption. Using a series of blocker molecules specific to different mechanotransducers, we demonstrated the pivotal role of actin network in keratinocyte mechanoresponsiveness in conjugation with myosin and lipid rafts. Flow-induced shear stress also induced significant elevation in E-cadherin and Zonula occludens-1 (ZO-1) expression levels. We further showed that under the influence of shear stress, the extent of colocalization of E-cadherin and ZO-1 was more at the cell-cell junction that indicates an improvement in the epithelial phenotype. An increase in the expression of nuclear lamin was also observed in the sheared cells that suggest the transmission of mechanical signals to the nucleus. It is envisioned that this study may find its application in basic and applied organogenesis of the epidermis.
Collapse
Affiliation(s)
- Tarun Agarwal
- Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, India.,Department of Biotechnology, Indian Institute of Technology Kharagpur, India
| | - Gautham H Narayana
- Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, India.,Jacques Monod Institute, Paris Diderot University & CNRS, Paris, France
| | - Indranil Banerjee
- Department of Biotechnology and Medical Engineering, National Institute of Technology Rourkela, India
| |
Collapse
|
14
|
Mittal R, Woo FW, Castro CS, Cohen MA, Karanxha J, Mittal J, Chhibber T, Jhaveri VM. Organ‐on‐chip models: Implications in drug discovery and clinical applications. J Cell Physiol 2018; 234:8352-8380. [DOI: 10.1002/jcp.27729] [Citation(s) in RCA: 112] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Accepted: 10/22/2018] [Indexed: 12/14/2022]
Affiliation(s)
- Rahul Mittal
- Department of Otolaryngology University of Miami Miller School of Medicine Miami Florida
| | - Frank W. Woo
- Department of Otolaryngology University of Miami Miller School of Medicine Miami Florida
| | - Carlo S. Castro
- Department of Otolaryngology University of Miami Miller School of Medicine Miami Florida
| | - Madeline A. Cohen
- Department of Otolaryngology University of Miami Miller School of Medicine Miami Florida
| | - Joana Karanxha
- Department of Otolaryngology University of Miami Miller School of Medicine Miami Florida
| | - Jeenu Mittal
- Department of Otolaryngology University of Miami Miller School of Medicine Miami Florida
| | - Tanya Chhibber
- University Institute of Pharmaceutical Sciences, UGC Centre of Advanced Studies, Panjab University Chandigarh India
| | - Vasanti M. Jhaveri
- Department of Otolaryngology University of Miami Miller School of Medicine Miami Florida
| |
Collapse
|
15
|
Jover E, Fagnano M, Angelini G, Madeddu P. Cell Sources for Tissue Engineering Strategies to Treat Calcific Valve Disease. Front Cardiovasc Med 2018; 5:155. [PMID: 30460245 PMCID: PMC6232262 DOI: 10.3389/fcvm.2018.00155] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Accepted: 10/10/2018] [Indexed: 12/15/2022] Open
Abstract
Cardiovascular calcification is an independent risk factor and an established predictor of adverse cardiovascular events. Despite concomitant factors leading to atherosclerosis and heart valve disease (VHD), the latter has been identified as an independent pathological entity. Calcific aortic valve stenosis is the most common form of VDH resulting of either congenital malformations or senile “degeneration.” About 2% of the population over 65 years is affected by aortic valve stenosis which represents a major cause of morbidity and mortality in the elderly. A multifactorial, complex and active heterotopic bone-like formation process, including extracellular matrix remodeling, osteogenesis and angiogenesis, drives heart valve “degeneration” and calcification, finally causing left ventricle outflow obstruction. Surgical heart valve replacement is the current therapeutic option for those patients diagnosed with severe VHD representing more than 20% of all cardiac surgeries nowadays. Tissue Engineering of Heart Valves (TEHV) is emerging as a valuable alternative for definitive treatment of VHD and promises to overcome either the chronic oral anticoagulation or the time-dependent deterioration and reintervention of current mechanical or biological prosthesis, respectively. Among the plethora of approaches and stablished techniques for TEHV, utilization of different cell sources may confer of additional properties, desirable and not, which need to be considered before moving from the bench to the bedside. This review aims to provide a critical appraisal of current knowledge about calcific VHD and to discuss the pros and cons of the main cell sources tested in studies addressing in vitro TEHV.
Collapse
Affiliation(s)
- Eva Jover
- Bristol Medical School (Translational Health Sciences), Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| | - Marco Fagnano
- Bristol Medical School (Translational Health Sciences), Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| | - Gianni Angelini
- Bristol Medical School (Translational Health Sciences), Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| | - Paolo Madeddu
- Bristol Medical School (Translational Health Sciences), Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
| |
Collapse
|
16
|
Ergir E, Bachmann B, Redl H, Forte G, Ertl P. Small Force, Big Impact: Next Generation Organ-on-a-Chip Systems Incorporating Biomechanical Cues. Front Physiol 2018; 9:1417. [PMID: 30356887 PMCID: PMC6190857 DOI: 10.3389/fphys.2018.01417] [Citation(s) in RCA: 56] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2018] [Accepted: 09/18/2018] [Indexed: 12/13/2022] Open
Abstract
Mechanobiology-on-a-chip is a growing field focusing on how mechanical inputs modulate physico-chemical output in microphysiological systems. It is well known that biomechanical cues trigger a variety of molecular events and adjustment of mechanical forces is therefore essential for mimicking in vivo physiologies in organ-on-a-chip technology. Biomechanical inputs in organ-on-a-chip systems can range from variations in extracellular matrix type and stiffness and applied shear stresses to active stretch/strain or compression forces using integrated flexible membranes. The main advantages of these organ-on-a-chip systems are therefore (a) the control over spatiotemporal organization of in vivo-like tissue architectures, (b) the ability to precisely control the amount, duration and intensity of the biomechanical stimuli, and (c) the capability of monitoring in real time the effects of applied mechanical forces on cell, tissue and organ functions. Consequently, over the last decade a variety of microfluidic devices have been introduced to recreate physiological microenvironments that also account for the influence of physical forces on biological functions. In this review we present recent advances in mechanobiological lab-on-a-chip systems and report on lessons learned from these current mechanobiological models. Additionally, future developments needed to engineer next-generation physiological and pathological organ-on-a-chip models are discussed.
Collapse
Affiliation(s)
- Ece Ergir
- Center for Translational Medicine, International Clinical Research Center, St. Anne’s University Hospital, Brno, Czechia
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry and Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna, Austria
| | - Barbara Bachmann
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry and Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna, Austria
- AUVA Research Centre, Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Vienna, Austria
- Austrian Cluster for Tissue Regeneration, Vienna, Austria
- Kompetenzzentrum für MechanoBiologie (INTERREG V-A Austria – Czech Republic Programme, ATCZ133), Vienna, Austria
| | - Heinz Redl
- AUVA Research Centre, Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Vienna, Austria
- Austrian Cluster for Tissue Regeneration, Vienna, Austria
- Kompetenzzentrum für MechanoBiologie (INTERREG V-A Austria – Czech Republic Programme, ATCZ133), Vienna, Austria
| | - Giancarlo Forte
- Center for Translational Medicine, International Clinical Research Center, St. Anne’s University Hospital, Brno, Czechia
- Competence Center for Mechanobiology (INTERREG V-A Austria – Czech Republic Programme, ATCZ133), Brno, Czechia
- Department of Biomaterials Science, Institute of Dentistry, University of Turku, Turku, Finland
| | - Peter Ertl
- Faculty of Technical Chemistry, Institute of Applied Synthetic Chemistry and Institute of Chemical Technologies and Analytics, Vienna University of Technology, Vienna, Austria
- Austrian Cluster for Tissue Regeneration, Vienna, Austria
- Kompetenzzentrum für MechanoBiologie (INTERREG V-A Austria – Czech Republic Programme, ATCZ133), Vienna, Austria
| |
Collapse
|
17
|
Lee DW, Choi N, Sung JH. A microfluidic chip with gravity-induced unidirectional flow for perfusion cell culture. Biotechnol Prog 2018; 35:e2701. [PMID: 30294886 DOI: 10.1002/btpr.2701] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 07/30/2018] [Indexed: 12/22/2022]
Abstract
Perfusion flow is one of the essential elements and advantages of organ-on-a-chip technology. For example, microfluidics have enabled implementation of perfusion flow and recapitulation of fluidic environment for vascular endothelial cells. The most prevalent method of implementing flow in a chip is to use a pump, which requires elaborate manipulation and complex connections, and accompanies a large amount of dead volume. Previously we devised a gravity-induced flow system which does not require tubing connections, but this method results in bidirectional flow to enable recirculation, which is somewhat different from physiological blood flow. Here, we have developed a novel microfluidic chip that enables gravity-induced, unidirectional flow by using a bypass channel with geometry different from the main channel. Human umbilical vein endothelial cells were cultured inside the chip and the effect of flow direction was examined. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 35: e2701, 2019.
Collapse
Affiliation(s)
- Dong Wook Lee
- Dept. of Chemical Engineering, Hongik University, Seoul 04066, Republic of Korea
| | - Nakwon Choi
- Center for BioMicrosystems, Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, South Korea
| | - Jong Hwan Sung
- Dept. of Chemical Engineering, Hongik University, Seoul 04066, Republic of Korea
| |
Collapse
|
18
|
Lee J, Estlack Z, Somaweera H, Wang X, Lacerda CMR, Kim J. A microfluidic cardiac flow profile generator for studying the effect of shear stress on valvular endothelial cells. LAB ON A CHIP 2018; 18:2946-2954. [PMID: 30123895 DOI: 10.1039/c8lc00545a] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
To precisely investigate the mechanobiological responses of valvular endothelial cells, we developed a microfluidic flow profile generator using a pneumatically-actuated micropump consisting of microvalves of various sizes. By controlling the closing pressures and the actuation times of these microvalves, we modulated the magnitude and frequency of the shear stress to mimic mitral and aortic inflow profiles with frequencies in the range of 0.8-2 Hz and shear stresses up to 20 dyn cm-2. To demonstrate this flow profile generator, aortic inflow with an average of 5.9 dyn cm-2 shear stress at a frequency of 1.2 Hz with a Reynolds number of 2.75, a Womersley number of 0.27, and an oscillatory shear index (OSI) value of 0.2 was applied to porcine aortic valvular endothelial cells (PAVECs) for mechanobiological studies. The cell alignment, cell elongation, and alpha-smooth muscle actin (αSMA) expression of PAVECs under perfusion, steady flow, and aortic inflow conditions were analyzed to determine their shear-induced cell migration and trans-differentiation. In this morphological and immunocytochemical study, we found that the PAVECs elongated and aligned themselves perpendicular to the directions of the steady flow and the aortic inflow. In contrast, under perfusion with a fluidic shear stress of 0.47 dyn cm-2, the PAVECs elongated and aligned themselves parallel to the direction of flow. The PAVECs exposed to the aortic inflow upregulated their αSMA-protein expression to a greater degree than those exposed to perfusion and steady flow. By comparing these results to those of previous studies of pulsatile flow, we also found that the ratio of positive to negative shear stress plays an important role in determining PAVECs' trans-differentiation and adaptation to flow. This microfluidic cardiac flow profile generator will enable future valvular mechanobiological studies to determine the roles of magnitude and frequency of shear stresses.
Collapse
Affiliation(s)
- Joohyung Lee
- Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409, USA.
| | | | | | | | | | | |
Collapse
|