1
|
van den Hoek TC, van de Ruit M, Terwindt GM, Tolner EA. EEG Changes in Migraine-Can EEG Help to Monitor Attack Susceptibility? Brain Sci 2024; 14:508. [PMID: 38790486 PMCID: PMC11119734 DOI: 10.3390/brainsci14050508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 04/30/2024] [Accepted: 05/01/2024] [Indexed: 05/26/2024] Open
Abstract
Migraine is a highly prevalent brain condition with paroxysmal changes in brain excitability believed to contribute to the initiation of an attack. The attacks and their unpredictability have a major impact on the lives of patients. Clinical management is hampered by a lack of reliable predictors for upcoming attacks, which may help in understanding pathophysiological mechanisms to identify new treatment targets that may be positioned between the acute and preventive possibilities that are currently available. So far, a large range of studies using conventional hospital-based EEG recordings have provided contradictory results, with indications of both cortical hyper- as well as hypo-excitability. These heterogeneous findings may largely be because most studies were cross-sectional in design, providing only a snapshot in time of a patient's brain state without capturing day-to-day fluctuations. The scope of this narrative review is to (i) reflect on current knowledge on EEG changes in the context of migraine, the attack cycle, and underlying pathophysiology; (ii) consider the effects of migraine treatment on EEG features; (iii) outline challenges and opportunities in using EEG for monitoring attack susceptibility; and (iv) discuss future applications of EEG in home-based settings.
Collapse
Affiliation(s)
- Thomas C. van den Hoek
- Department of Neurology, Leiden University Medical Centre, 2333 ZA Leiden, The Netherlands (M.v.d.R.); (G.M.T.)
| | - Mark van de Ruit
- Department of Neurology, Leiden University Medical Centre, 2333 ZA Leiden, The Netherlands (M.v.d.R.); (G.M.T.)
- Department of Biomechanical Engineering, Delft University of Technology, 2628 CD Delft, The Netherlands
| | - Gisela M. Terwindt
- Department of Neurology, Leiden University Medical Centre, 2333 ZA Leiden, The Netherlands (M.v.d.R.); (G.M.T.)
| | - Else A. Tolner
- Department of Neurology, Leiden University Medical Centre, 2333 ZA Leiden, The Netherlands (M.v.d.R.); (G.M.T.)
- Department of Human Genetics, Leiden University Medical Centre, 2300 RC Leiden, The Netherlands
| |
Collapse
|
2
|
Yue H, Chen Z, Guo W, Sun L, Dai Y, Wang Y, Ma W, Fan X, Wen W, Lei W. Research and application of deep learning-based sleep staging: Data, modeling, validation, and clinical practice. Sleep Med Rev 2024; 74:101897. [PMID: 38306788 DOI: 10.1016/j.smrv.2024.101897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 12/30/2023] [Accepted: 01/04/2024] [Indexed: 02/04/2024]
Abstract
Over the past few decades, researchers have attempted to simplify and accelerate the process of sleep stage classification through various approaches; however, only a few such approaches have gained widespread acceptance. Artificial intelligence technology, particularly deep learning, is promising for earning the trust of the sleep medicine community in automated sleep-staging systems, thus facilitating its application in clinical practice and integration into daily life. We aimed to comprehensively review the latest methods that are applying deep learning for enhancing sleep staging efficiency and accuracy. Starting from the requisite "data" for constructing deep learning algorithms, we elucidated the current landscape of this domain and summarized the fundamental modeling process, encompassing signal selection, data pre-processing, model architecture, classification tasks, and performance metrics. Furthermore, we reviewed the applications of automated sleep staging in scenarios such as sleep-disorder screening, diagnostic procedures, and health monitoring and management. Finally, we conducted an in-depth analysis and discussion of the challenges and future in intelligent sleep staging, particularly focusing on large-scale sleep datasets, interdisciplinary collaborations, and human-computer interactions.
Collapse
Affiliation(s)
- Huijun Yue
- Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, People's Republic of China
| | - Zhuqi Chen
- Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, People's Republic of China
| | - Wenbin Guo
- Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, People's Republic of China
| | - Lin Sun
- Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, People's Republic of China
| | - Yidan Dai
- School of Computer Science, South China Normal University, Guangzhou, People's Republic of China
| | - Yiming Wang
- Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, People's Republic of China
| | - Wenjun Ma
- School of Computer Science, South China Normal University, Guangzhou, People's Republic of China
| | - Xiaomao Fan
- College of Big Data and Internet, Shenzhen Technology University, Shenzhen, People's Republic of China
| | - Weiping Wen
- Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, People's Republic of China; Department of Otolaryngology, The Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, People's Republic of China.
| | - Wenbin Lei
- Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, People's Republic of China.
| |
Collapse
|
3
|
Lin S, Jiang J, Huang K, Li L, He X, Du P, Wu Y, Liu J, Li X, Huang Z, Zhou Z, Yu Y, Gao J, Lei M, Wu H. Advanced Electrode Technologies for Noninvasive Brain-Computer Interfaces. ACS NANO 2023; 17:24487-24513. [PMID: 38064282 DOI: 10.1021/acsnano.3c06781] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2023]
Abstract
Brain-computer interfaces (BCIs) have garnered significant attention in recent years due to their potential applications in medical, assistive, and communication technologies. Building on this, noninvasive BCIs stand out as they provide a safe and user-friendly method for interacting with the human brain. In this work, we provide a comprehensive overview of the latest developments and advancements in material, design, and application of noninvasive BCIs electrode technology. We also explore the challenges and limitations currently faced by noninvasive BCI electrode technology and sketch out the technological roadmap from three dimensions: Materials and Design; Performances; Mode and Function. We aim to unite research efforts within the field of noninvasive BCI electrode technology, focusing on the consolidation of shared goals and fostering integrated development strategies among a diverse array of multidisciplinary researchers.
Collapse
Affiliation(s)
- Sen Lin
- School of Physical Science and Technology, Guangxi University, Nanning 530004, China
| | - Jingjing Jiang
- School of Physical Science and Technology, Guangxi University, Nanning 530004, China
| | - Kai Huang
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
- State Key Laboratory of Information Photonics and Optical Communications and School of Science, Beijing University of Posts and Telecommunications, Beijing 100876, China
| | - Lei Li
- National Engineering Research Center of Electric Vehicles, Beijing Institute of Technology, Beijing 100081, China
| | - Xian He
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
| | - Peng Du
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
| | - Yufeng Wu
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
| | - Junchen Liu
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
- State Key Laboratory of Information Photonics and Optical Communications and School of Science, Beijing University of Posts and Telecommunications, Beijing 100876, China
| | - Xilin Li
- School of Physical Science and Technology, Guangxi University, Nanning 530004, China
- Advanced Institute for Brain and Intelligence, Guangxi University, Nanning 530004, China
| | - Zhibao Huang
- School of Physical Science and Technology, Guangxi University, Nanning 530004, China
| | - Zenan Zhou
- School of Physical Science and Technology, Guangxi University, Nanning 530004, China
| | - Yuanhang Yu
- School of Physical Science and Technology, Guangxi University, Nanning 530004, China
| | - Jiaxin Gao
- School of Physical Science and Technology, Guangxi University, Nanning 530004, China
| | - Ming Lei
- State Key Laboratory of Information Photonics and Optical Communications and School of Science, Beijing University of Posts and Telecommunications, Beijing 100876, China
| | - Hui Wu
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
| |
Collapse
|
4
|
Fiedler P, Graichen U, Zimmer E, Haueisen J. Simultaneous Dry and Gel-Based High-Density Electroencephalography Recordings. SENSORS (BASEL, SWITZERLAND) 2023; 23:9745. [PMID: 38139591 PMCID: PMC10747542 DOI: 10.3390/s23249745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 12/06/2023] [Accepted: 12/08/2023] [Indexed: 12/24/2023]
Abstract
Evaluations of new dry, high-density EEG caps have only been performed so far with serial measurements and not with simultaneous (parallel) measurements. For a first comparison of gel-based and dry electrode performance in simultaneous high-density EEG measurements, we developed a new EEG cap comprising 64 gel-based and 64 dry electrodes and performed simultaneous measurements on ten volunteers. We analyzed electrode-skin impedances, resting state EEG, triggered eye blinks, and visual evoked potentials (VEPs). To overcome the issue of different electrode positions in the comparison of simultaneous measurements, we performed spatial frequency analysis of the simultaneously measured EEGs using spatial harmonic analysis (SPHARA). The impedances were 516 ± 429 kOhm (mean ± std) for the dry electrodes and 14 ± 8 kOhm for the gel-based electrodes. For the dry EEG electrodes, we obtained a channel reliability of 77%. We observed no differences between dry and gel-based recordings for the alpha peak frequency and the alpha power amplitude, as well as for the VEP peak amplitudes and latencies. For the VEP, the RMSD and the correlation coefficient between the gel-based and dry recordings were 1.7 ± 0.7 μV and 0.97 ± 0.03, respectively. We observed no differences in the cumulative power distributions of the spatial frequency components for the N75 and P100 VEP peaks. The differences for the N145 VEP peak were attributed to the different noise characteristics of gel-based and dry recordings. In conclusion, we provide evidence for the equivalence of simultaneous dry and gel-based high-density EEG measurements.
Collapse
Affiliation(s)
- Patrique Fiedler
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| | - Uwe Graichen
- Department of Biostatistics and Data Science, Karl Landsteiner University of Health Sciences, 3500 Krems an der Donau, Austria
| | - Ellen Zimmer
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| |
Collapse
|
5
|
Tamburro G, Fiedler P, De Fano A, Raeisi K, Khazaei M, Vaquero L, Bruña R, Oppermann H, Bertollo M, Filho E, Zappasodi F, Comani S. An ecological study protocol for the multimodal investigation of the neurophysiological underpinnings of dyadic joint action. Front Hum Neurosci 2023; 17:1305331. [PMID: 38125713 PMCID: PMC10730734 DOI: 10.3389/fnhum.2023.1305331] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Accepted: 11/15/2023] [Indexed: 12/23/2023] Open
Abstract
A novel multimodal experimental setup and dyadic study protocol were designed to investigate the neurophysiological underpinnings of joint action through the synchronous acquisition of EEG, ECG, EMG, respiration and kinematic data from two individuals engaged in ecologic and naturalistic cooperative and competitive joint actions involving face-to-face real-time and real-space coordinated full body movements. Such studies are still missing because of difficulties encountered in recording reliable neurophysiological signals during gross body movements, in synchronizing multiple devices, and in defining suitable study protocols. The multimodal experimental setup includes the synchronous recording of EEG, ECG, EMG, respiration and kinematic signals of both individuals via two EEG amplifiers and a motion capture system that are synchronized via a single-board microcomputer and custom Python scripts. EEG is recorded using new dry sports electrode caps. The novel study protocol is designed to best exploit the multimodal data acquisitions. Table tennis is the dyadic motor task: it allows naturalistic and face-to-face interpersonal interactions, free in-time and in-space full body movement coordination, cooperative and competitive joint actions, and two task difficulty levels to mimic changing external conditions. Recording conditions-including minimum table tennis rally duration, sampling rate of kinematic data, total duration of neurophysiological recordings-were defined according to the requirements of a multilevel analytical approach including a neural level (hyperbrain functional connectivity, Graph Theoretical measures and Microstate analysis), a cognitive-behavioral level (integrated analysis of neural and kinematic data), and a social level (extending Network Physiology to neurophysiological data recorded from two interacting individuals). Four practical tests for table tennis skills were defined to select the study population, permitting to skill-match the dyad members and to form two groups of higher and lower skilled dyads to explore the influence of skill level on joint action performance. Psychometric instruments are included to assess personality traits and support interpretation of results. Studying joint action with our proposed protocol can advance the understanding of the neurophysiological mechanisms sustaining daily life joint actions and could help defining systems to predict cooperative or competitive behaviors before being overtly expressed, particularly useful in real-life contexts where social behavior is a main feature.
Collapse
Affiliation(s)
- Gabriella Tamburro
- Department of Neuroscience Imaging and Clinical Sciences, University “G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
- Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
| | - Patrique Fiedler
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany
| | - Antonio De Fano
- Department of Neuroscience Imaging and Clinical Sciences, University “G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
- Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
| | - Khadijeh Raeisi
- Department of Neuroscience Imaging and Clinical Sciences, University “G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
| | - Mohammad Khazaei
- Department of Neuroscience Imaging and Clinical Sciences, University “G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
| | - Lucia Vaquero
- Center for Cognitive and Computational Neuroscience, Universidad Complutense de Madrid, Madrid, Spain
- Department of Experimental Pschology, Cognitive Processes and Speech Therapy, Universidad Complutense de Madrid, Madrid, Spain
| | - Ricardo Bruña
- Center for Cognitive and Computational Neuroscience, Universidad Complutense de Madrid, Madrid, Spain
- Department of Radiology, Universidad Complutense de Madrid, IdISSC, Madrid, Spain
| | - Hannes Oppermann
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany
| | - Maurizio Bertollo
- Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
- Department of Medicine and Sciences of Aging, “University G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
| | - Edson Filho
- Wheelock College of Education and Human Development, Boston University, Boston, MA, United States
| | - Filippo Zappasodi
- Department of Neuroscience Imaging and Clinical Sciences, University “G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
- Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
| | - Silvia Comani
- Department of Neuroscience Imaging and Clinical Sciences, University “G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
- Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti–Pescara, Chieti, Italy
| |
Collapse
|
6
|
Warsito IF, Komosar M, Bernhard MA, Fiedler P, Haueisen J. Flower electrodes for comfortable dry electroencephalography. Sci Rep 2023; 13:16589. [PMID: 37789022 PMCID: PMC10547758 DOI: 10.1038/s41598-023-42732-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 09/14/2023] [Indexed: 10/05/2023] Open
Abstract
Dry electroencephalography (EEG) electrodes provide rapid, gel-free, and easy EEG preparation, but with limited wearing comfort. We propose a novel dry electrode comprising multiple tilted pins in a flower-like arrangement. The novel Flower electrode increases wearing comfort and contact area while maintaining ease of use. In a study with 20 volunteers, we compare the performance of a novel 64-channel dry Flower electrode cap to a commercial dry Multipin electrode cap in sitting and supine positions. The wearing comfort of the Flower cap was rated as significantly improved both in sitting and supine positions. The channel reliability and average impedances of both electrode systems were comparable. Averaged VEP components showed no considerable differences in global field power amplitude and latency, as well as in signal-to-noise ratio and topography. No considerable differences were found in the power spectral density of the resting state EEGs between 1 and 40 Hz. Overall, our findings provide evidence for equivalent channel reliability and signal characteristics of the compared cap systems in the sitting and supine positions. The reliability, signal quality, and significantly improved wearing comfort of the Flower electrode allow new fields of applications for dry EEG in long-term monitoring, sensitive populations, and recording in supine position.
Collapse
Affiliation(s)
- Indhika Fauzhan Warsito
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Milana Komosar
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Maria Anne Bernhard
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Patrique Fiedler
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics at the Technische Universität Ilmenau, Ilmenau, Germany.
- Department of Neurology, Biomagnetic Center, University Hospital Jena, Jena, Germany.
| |
Collapse
|
7
|
van Stigt MN, Groenendijk EA, van de Munckhof AAGA, Marquering HA, Koopman MS, Majoie CBLM, Roos YBWEM, Koelman JHTM, Potters WV, Coutinho JM. Correlation between EEG spectral power and cerebral perfusion in patients with acute ischemic stroke. J Clin Neurosci 2023; 116:81-86. [PMID: 37657169 DOI: 10.1016/j.jocn.2023.08.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 08/08/2023] [Accepted: 08/23/2023] [Indexed: 09/03/2023]
Abstract
Dry electrode electroencephalography (EEG) has the potential to diagnose ischemic stroke in the acute phase. In the current study we determined the correlation between EEG spectral power and ischemic stroke size and location as determined by computed tomography perfusion (CTP). Dry electrode EEG recordings were performed in patients with acute ischemic stroke in the emergency room. CTP preceded the EEG recordings as part of standard imaging protocol. Infarct core volume, total hypoperfused volume and local cerebral blood flow (CBF) were estimated with CTP. Additionally, global and local EEG spectral power were determined. We used Spearman's correlation coefficients to evaluate the correlation between variables. We included 27 patients (median age 72 [IQR:69-80] years, 15/27 [56%] men). Median CTP-to-EEG time was 32 (range:8-138) minutes. Hypoperfused volumes were estimated for 12/27 (44%) patients. Infarct core volume correlated best with global delta power (ρ = 0.76, p < 0.01), total hypoperfused volume with global alpha power (ρ = -0.58, p = 0.05), and local CBF with local alpha power (ρ = 0.43, p < 0.01). We conclude that dry electrode EEG signals slow down with increasing hypoperfused volume, which could potentially be used to discriminate between small and large ischemic strokes.
Collapse
Affiliation(s)
- M N van Stigt
- Department of Clinical Neurophysiology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands; Department of Neurology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands.
| | - E A Groenendijk
- Department of Clinical Neurophysiology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands; Department of Neurology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
| | - A A G A van de Munckhof
- Department of Clinical Neurophysiology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands; Department of Neurology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
| | - H A Marquering
- Department of Biomedical Engineering and Physics, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands; Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
| | - M S Koopman
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
| | - C B L M Majoie
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
| | - Y B W E M Roos
- Department of Neurology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
| | - J H T M Koelman
- Department of Clinical Neurophysiology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands; Department of Neurology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
| | - W V Potters
- Department of Neurology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands; TrianecT, Padualaan 8, Utrecht, the Netherlands
| | - J M Coutinho
- Department of Neurology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
| |
Collapse
|
8
|
Ogawa A, Koganemaru S, Takahashi T, Takemura Y, Irisawa H, Goto K, Matsuhashi M, Mima T, Mizushima T, Kansaku K. Swallow-related Brain Activity in Post-total Laryngectomy Patients: A Case Series Study. Prog Rehabil Med 2023; 8:20230026. [PMID: 37663527 PMCID: PMC10468693 DOI: 10.2490/prm.20230026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 07/26/2023] [Indexed: 09/05/2023] Open
Abstract
Background Total laryngectomy is a surgical procedure to completely remove the hyoid bone, larynx, and associated muscles as a curative treatment for laryngeal cancer. This leads to insufficient swallowing function with compensative movements of the residual tongue to propel the food bolus to the pharynx and esophagus. However, the neurophysiological mechanisms of compensative swallowing after total laryngectomy remain unclear. Recently, swallowing-related cortical activation such as event-related desynchronization (ERD) during swallowing has been reported in healthy participants and neurological patients with dysphagia. Abnormal ERD elucidates the pathophysiological cortical activities that are related to swallowing. No report has investigated ERD in post-total laryngectomy patients. Case We investigated ERD during volitional swallowing using electroencephalography in three male patients after total laryngectomy for laryngeal cancer (age and time after surgery: Case 1, 75 years, 10 years; Case 2, 85 years, 19 years; Case 3, 73 years, 19 years). In video fluorographic swallowing studies, we observed compensatory tongue movements such as posterior-inferior retraction of the tongue and contact on the posterior pharyngeal wall in all three cases. Significant ERD was localized in the bilateral medial sensorimotor areas and the left lateral parietal area in Case 1, in the bilateral frontal and left temporal areas in Case 2, and in the left prefrontal and premotor areas in Case 3. Discussion These results suggest that cortical activities related to swallowing might reflect cortical reorganization for modified swallowing movements of residual tongue muscles to compensate for reduced swallowing pressure in patients after total laryngectomy.
Collapse
Affiliation(s)
- Akari Ogawa
- Cognitive Motor Neuroscience, Human Health Sciences,
Graduate School of Medicine, Kyoto University, Kyoto, Japan
- Department of Regenerative Systems Neuroscience, Human Brain
Research Center, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Satoko Koganemaru
- Department of Regenerative Systems Neuroscience, Human Brain
Research Center, Graduate School of Medicine, Kyoto University, Kyoto, Japan
- Department of Physiology, Dokkyo Medical University, Mibu,
Japan
| | | | - Yuu Takemura
- Department of Rehabilitation Medicine, Dokkyo Medical
University, Mibu, Japan
| | - Hiroshi Irisawa
- Department of Rehabilitation Medicine, Dokkyo Medical
University, Mibu, Japan
| | - Kazutaka Goto
- Department of Otorhinolaryngology, Head and Neck Surgery,
Dokkyo Medical University, Mibu, Japan
| | - Masao Matsuhashi
- Department of Epilepsy, Movement Disorders and Physiology,
Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Tatsuya Mima
- The Graduate School of Core Ethics and Frontier Sciences,
Ritsumeikan University, Kyoto, Japan
| | - Takashi Mizushima
- Department of Rehabilitation Medicine, Dokkyo Medical
University, Mibu, Japan
| | - Kenji Kansaku
- Department of Physiology, Dokkyo Medical University, Mibu,
Japan
| |
Collapse
|
9
|
van Stigt M, Groenendijk E, Marquering H, Coutinho J, Potters W. High performance clean versus artifact dry electrode EEG data classification using Convolutional Neural Network transfer learning. Clin Neurophysiol Pract 2023; 8:88-91. [PMID: 37215683 PMCID: PMC10196906 DOI: 10.1016/j.cnp.2023.04.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 04/06/2023] [Accepted: 04/08/2023] [Indexed: 05/24/2023] Open
Abstract
Objective Convolutional Neural Networks (CNNs) are promising for artifact detection in electroencephalography (EEG) data, but require large amounts of data. Despite increasing use of dry electrodes for EEG data acquisition, dry electrode EEG datasets are sparse. We aim to develop an algorithm for clean versus artifact dry electrode EEG data classification using transfer learning. Methods Dry electrode EEG data were acquired in 13 subjects while physiological and technical artifacts were induced. Data were per 2-second segment labeled as clean or artifact and split in an 80% train and 20% test set. With the train set, we fine-tuned a pre-trained CNN for clean versus artifact wet electrode EEG data classification using 3-fold cross validation. The three fine-tuned CNNs were combined in one final clean versus artifact classification algorithm, in which the majority vote was used for classification. We calculated accuracy, F1-score, precision, and recall of the pre-trained CNN and fine-tuned algorithm when applied to unseen test data. Results The algorithm was trained on 0.40 million and tested on 0.17 million overlapping EEG segments. The pre-trained CNN had a test accuracy of 65.6%. The fine-tuned clean versus artifact classification algorithm had an improved test accuracy of 90.7%, F1-score of 90.2%, precision of 89.1% and recall of 91.2%. Conclusions Despite a relatively small dry electrode EEG dataset, transfer learning enabled development of a high performing CNN-based algorithm for clean versus artifact classification. Significance Development of CNNs for classification of dry electrode EEG data is challenging as dry electrode EEG datasets are sparse. Here, we show that transfer learning can be used to overcome this problem.
Collapse
Affiliation(s)
- M.N. van Stigt
- Amsterdam UMC location University of Amsterdam, Department of Clinical Neurophysiology, Meibergdreef 9, Amsterdam, the Netherlands
- Amsterdam UMC location University of Amsterdam, Department of Neurology, Meibergdreef 9, Amsterdam, the Netherlands
| | - E.A. Groenendijk
- Amsterdam UMC location University of Amsterdam, Department of Clinical Neurophysiology, Meibergdreef 9, Amsterdam, the Netherlands
- Amsterdam UMC location University of Amsterdam, Department of Neurology, Meibergdreef 9, Amsterdam, the Netherlands
| | - H.A. Marquering
- Amsterdam UMC location University of Amsterdam, Department of Biomedical Engineering and Physics, Meibergdreef 9, Amsterdam, the Netherlands
- Amsterdam UMC location University of Amsterdam, Department of Radiology and Nuclear Medicine, Meibergdreef 9, Amsterdam, the Netherlands
| | - J.M. Coutinho
- Amsterdam UMC location University of Amsterdam, Department of Neurology, Meibergdreef 9, Amsterdam, the Netherlands
| | - W.V. Potters
- Amsterdam UMC location University of Amsterdam, Department of Clinical Neurophysiology, Meibergdreef 9, Amsterdam, the Netherlands
- Amsterdam UMC location University of Amsterdam, Department of Neurology, Meibergdreef 9, Amsterdam, the Netherlands
| |
Collapse
|
10
|
Fiedler P, Haueisen J, Alvarez AMC, Cheron G, Cuesta P, Maestú F, Funke M. Noise characteristics in spaceflight multichannel EEG. PLoS One 2023; 18:e0280822. [PMID: 36800392 PMCID: PMC9937484 DOI: 10.1371/journal.pone.0280822] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 01/06/2023] [Indexed: 02/18/2023] Open
Abstract
The cognitive performance of the crew has a major impact on mission safety and success in space flight. Monitoring of cognitive performance during long-duration space flight therefore is of paramount importance and can be performed using compact state-of-the-art mobile EEG. However, signal quality of EEG may be compromised due to the vicinity to various electronic devices and constant movements. We compare noise characteristics between in-flight extraterrestrial microgravity and ground-level terrestrial electroencephalography (EEG) recordings. EEG data recordings from either aboard International Space Station (ISS) or on earth's surface, utilizing three EEG amplifiers and two electrode types, were compared. In-flight recordings showed noise level of an order of magnitude lower when compared to pre- and post-flight ground-level recordings with the same EEG system. Noise levels between ground-level recordings with actively shielded cables, and in-flight recordings without shielded cables, were similar. Furthermore, noise level characteristics of shielded ground-level EEG recordings, using wet and dry electrodes, and in-flight EEG recordings were similar. Actively shielded mobile dry EEG systems will support neuroscientific research and neurocognitive monitoring during spaceflight, especially during long-duration space missions.
Collapse
Affiliation(s)
- Patrique Fiedler
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany,* E-mail:
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany
| | | | - Guy Cheron
- Université Libre de Bruxelles, Brussels, Belgium
| | | | | | - Michael Funke
- McGovern Medical School, University of Texas, Houston, Texas, United States of America
| |
Collapse
|
11
|
Liu Q, Yang L, Zhang Z, Yang H, Zhang Y, Wu J. The Feature, Performance, and Prospect of Advanced Electrodes for Electroencephalogram. BIOSENSORS 2023; 13:bios13010101. [PMID: 36671936 PMCID: PMC9855417 DOI: 10.3390/bios13010101] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/22/2022] [Accepted: 01/03/2023] [Indexed: 05/12/2023]
Abstract
Recently, advanced electrodes have been developed, such as semi-dry, dry contact, dry non-contact, and microneedle array electrodes. They can overcome the issues of wet electrodes and maintain high signal quality. However, the variations in these electrodes are still unclear and not explained, and there is still confusion regarding the feasibility of electrodes for different application scenarios. In this review, the physical features and electroencephalogram (EEG) signal performances of these advanced EEG electrodes are introduced in view of the differences in contact between the skin and electrodes. Specifically, contact features, biofeatures, impedance, signal quality, and artifacts are discussed. The application scenarios and prospects of different types of EEG electrodes are also elucidated.
Collapse
|
12
|
Freund BE, Feyissa AM. EEG as an indispensable tool during and after the COVID-19 pandemic: A review of tribulations and successes. Front Neurol 2022; 13:1087969. [PMID: 36530612 PMCID: PMC9755176 DOI: 10.3389/fneur.2022.1087969] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Accepted: 11/17/2022] [Indexed: 10/03/2023] Open
Abstract
During the coronavirus disease 2019 (COVID-19) pandemic, elective and non-emergent tests and procedures were delayed or suspended in lieu of diverting resources to more emergent treatment of critically ill patients and to avoid the spread and contraction of COVID-19. Further, the workforce was stretched thin, and healthcare facilities saw high turnover rates for full-time and contract employees, which strained the system and reduced the ability to provide clinical services. One of the casualties of these changes was electroencephalography (EEG) procedures, which have been performed less frequently throughout the world since the pandemic. Whether considered routine or emergent, the deferral of EEG studies can cause downstream effects, including a delay in diagnosis and initiation of treatment for epilepsy and non-epileptic seizures resulting in a higher risk of morbidity and mortality. Despite these limitations, the importance and utility of EEG and EEG technologists have been reinforced with the development of COVID-related neurological complications, including encephalopathy and seizures, which require EEG for diagnosis and treatment. Since the pandemic, reliance on remote telemonitoring has further highlighted the value and ease of using EEG. There has also been a heightened interest in rapid EEG devices that non-technologist professionals can attach quickly, allowing minimum patient contact to avoid exposure to COVID-19 and taking advantage of remote EEG monitoring. This review discusses the acute and potential long-term effects of the COVID-19 pandemic on the use and performance of EEG.
Collapse
Affiliation(s)
| | - Anteneh M. Feyissa
- Department of Neurology, Mayo Clinic Florida, Jacksonville, FL, United States
| |
Collapse
|
13
|
Palucci Vieira LH, Carling C, da Silva JP, Santinelli FB, Polastri PF, Santiago PRP, Barbieri FA. Modelling the relationships between EEG signals, movement kinematics and outcome in soccer kicking. Cogn Neurodyn 2022; 16:1303-1321. [PMID: 36408067 PMCID: PMC9666621 DOI: 10.1007/s11571-022-09786-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Revised: 01/03/2022] [Accepted: 01/21/2022] [Indexed: 12/16/2022] Open
Abstract
The contribution of cortical activity (e.g. EEG recordings) in various brain regions to motor control during goal-directed manipulative tasks using lower limbs remains unexplored. Therefore, the aim of the current study was to determine the magnitude of associations between EEG-derived brain activity and soccer kicking parameters. Twenty-four under-17 players performed an instep kicking task (18 m from the goal) aiming to hit 1 × 1 m targets allocated in the goalpost upper corners in the presence of a goalkeeper. Using a portable 64-channel EEG system, brain oscillations in delta, theta, alpha, beta and gamma frequency bands were determined at the frontal, motor, parietal and occipital regions separately for three phases of the kicks: preparatory, approach and immediately prior to ball contact. Movement kinematic measures included segmental linear and relative velocities, angular joint displacement and velocities. Mean radial error and ball velocity were assumed as outcome indicators. A significant influence of frontal theta power immediately prior to ball contact was observed in the variance of ball velocity (R 2 = 35%, P = 0.01) while the expression of occipital alpha component recorded during the preparatory phase contributed to the mean radial error (R 2 = 20%, P = 0.049). Ankle eversion angle at impact moment likely mediated the association between frontal theta power and subsequent ball velocity (β = 0.151, P = 0.06). The present analysis showed that the brain signalling at cortical level may be determinant in movement control, ball velocity and accuracy when performing kick attempts from the edge of penalty area. Trial registration number #RBR-8prx2m-Brazilian Registry of Clinical Trials ReBec. Supplementary Information The online version contains supplementary material available at 10.1007/s11571-022-09786-2.
Collapse
Affiliation(s)
- Luiz H. Palucci Vieira
- Human Movement Research Laboratory (MOVI-LAB), Faculty of Sciences, Graduate Program in Movement Sciences, Department of Physical Education, São Paulo State University (Unesp), Av. Eng. Luís Edmundo Carrijo Coube, 2085 - Nucleo Res. Pres. Geisel, Bauru, SP 17033-360 Brazil
| | | | - João Pedro da Silva
- Human Movement Research Laboratory (MOVI-LAB), Faculty of Sciences, Graduate Program in Movement Sciences, Department of Physical Education, São Paulo State University (Unesp), Av. Eng. Luís Edmundo Carrijo Coube, 2085 - Nucleo Res. Pres. Geisel, Bauru, SP 17033-360 Brazil
| | - Felipe B. Santinelli
- Human Movement Research Laboratory (MOVI-LAB), Faculty of Sciences, Graduate Program in Movement Sciences, Department of Physical Education, São Paulo State University (Unesp), Av. Eng. Luís Edmundo Carrijo Coube, 2085 - Nucleo Res. Pres. Geisel, Bauru, SP 17033-360 Brazil
| | - Paula F. Polastri
- Laboratory of Information, Vision and Action (LIVIA), São Paulo State University (Unesp), Faculty of Sciences, Department of Physical Education, Graduate Program in Movement Sciences, Bauru, Brazil
| | - Paulo R. P. Santiago
- Biomechanics and Motor Control Laboratory (LaBioCoM), School of Physical Education and Sport of Ribeirão Preto (EEFERP), University of São Paulo (USP), Ribeirão Preto, Brazil
| | - Fabio A. Barbieri
- Human Movement Research Laboratory (MOVI-LAB), Faculty of Sciences, Graduate Program in Movement Sciences, Department of Physical Education, São Paulo State University (Unesp), Av. Eng. Luís Edmundo Carrijo Coube, 2085 - Nucleo Res. Pres. Geisel, Bauru, SP 17033-360 Brazil
| |
Collapse
|
14
|
Ng CR, Fiedler P, Kuhlmann L, Liley D, Vasconcelos B, Fonseca C, Tamburro G, Comani S, Lui TKY, Tse CY, Warsito IF, Supriyanto E, Haueisen J. Multi-Center Evaluation of Gel-Based and Dry Multipin EEG Caps. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22208079. [PMID: 36298430 PMCID: PMC9612204 DOI: 10.3390/s22208079] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Revised: 10/13/2022] [Accepted: 10/19/2022] [Indexed: 05/27/2023]
Abstract
Dry electrodes for electroencephalography (EEG) allow new fields of application, including telemedicine, mobile EEG, emergency EEG, and long-term repetitive measurements for research, neurofeedback, or brain-computer interfaces. Different dry electrode technologies have been proposed and validated in comparison to conventional gel-based electrodes. Most previous studies have been performed at a single center and by single operators. We conducted a multi-center and multi-operator study validating multipin dry electrodes to study the reproducibility and generalizability of their performance in different environments and for different operators. Moreover, we aimed to study the interrelation of operator experience, preparation time, and wearing comfort on the EEG signal quality. EEG acquisitions using dry and gel-based EEG caps were carried out in 6 different countries with 115 volunteers, recording electrode-skin impedances, resting state EEG and evoked activity. The dry cap showed average channel reliability of 81% but higher average impedances than the gel-based cap. However, the dry EEG caps required 62% less preparation time. No statistical differences were observed between the gel-based and dry EEG signal characteristics in all signal metrics. We conclude that the performance of the dry multipin electrodes is highly reproducible, whereas the primary influences on channel reliability and signal quality are operator skill and experience.
Collapse
Affiliation(s)
- Chuen Rue Ng
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| | - Patrique Fiedler
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| | - Levin Kuhlmann
- Faculty of Information Technology, Monash University, Building 63, 25 Exhibition Walk, Clayton, VIC 3800, Australia
| | - David Liley
- Brain and Psychological Sciences Research Centre, Swinburne University of Technology, P.O. Box 218, Hawthorn, VIC 3122, Australia
| | - Beatriz Vasconcelos
- Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
| | - Carlos Fonseca
- Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
- Institute of Science and Innovation in Mechanical and Industrial Engineering, LAETA/INEGI, 4200-465 Porto, Portugal
| | - Gabriella Tamburro
- BIND-Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti–Pescara, Via Luigi Polacchi, 11, 66100 Chieti, Italy
| | - Silvia Comani
- BIND-Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti–Pescara, Via Luigi Polacchi, 11, 66100 Chieti, Italy
| | - Troby Ka-Yan Lui
- Department of Psychology, University of Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
- Center of Brain, Behavior and Metabolism, University of Lübeck, Marie-Curie-Straße, 23562 Lübeck, Germany
| | - Chun-Yu Tse
- Department of Social and Behavioural Sciences, City University of Hong Kong, Hong Kong, China
| | - Indhika Fauzhan Warsito
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| | - Eko Supriyanto
- IJN-UTM Cardiovascular Engineering Centre, School of Biomedical Engineering & Health Sciences, Universiti Teknologi Malaysia, Johor Bahru 81300, Malaysia
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| |
Collapse
|
15
|
Baum U, Kühn F, Lichters M, Baum AK, Deike R, Hinrichs H, Neumann T. Neurological Outpatients Prefer EEG Home-Monitoring over Inpatient Monitoring-An Analysis Based on the UTAUT Model. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:13202. [PMID: 36293783 PMCID: PMC9603390 DOI: 10.3390/ijerph192013202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/07/2022] [Accepted: 10/09/2022] [Indexed: 06/16/2023]
Abstract
Home monitoring examinations offer diagnostic and economic advantages compared to inpatient monitoring. In addition, these technical solutions support the preservation of health care in rural areas in the absence of local care providers. The acceptance of patients is crucial for the implementation of home monitoring concepts. The present research assesses the preference for a health service that is to be introduced, namely an EEG home-monitoring of neurological outpatients-using a mobile, dry-electrode EEG (electroencephalography) system-in comparison to the traditional long-time EEG examination in a hospital. Results of a representative study for Germany (n = 421) reveal a preference for home monitoring. Importantly, this preference is partially driven by a video explaining the home monitoring system. We subsequently analyzed factors that influence the behavioral intention (BI) to use the new EEG system, drawing on an extended Unified Theory of Acceptance and Use of Technology (UTAUT) model. The strongest positive predictor of BI is the belief that EEG home-monitoring will improve health quality, while computer anxiety and effort expectancy represent the strongest barriers. Furthermore, we find the UTAUT model's behavioral intention construct to predict the patients' decision for or against home monitoring more strongly than any other patient's characteristic such as gender, health condition, or age, underlying the model's usefulness.
Collapse
Affiliation(s)
- Ulrike Baum
- Department of Neurology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany
| | - Frauke Kühn
- Institute for Sensory and Innovation Research (ISI GmbH), Ascherberg 2, 37124 Rosdorf, Germany
| | - Marcel Lichters
- Chair of Marketing and Retailing, Faculty of Economics and Business Administration, Chemnitz University of Technology, Reichenhainer Straße 39, 09126 Chemnitz, Germany
| | - Anne-Katrin Baum
- Department of Neurology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany
| | - Renate Deike
- Department of Neurology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany
| | - Hermann Hinrichs
- Department of Neurology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany
- Leibniz Institute for Neurobiology, Brenneckestraße 6, 39118 Magdeburg, Germany
- Center for Behavioral Brain Sciences (CBBS), Universitätsplatz 2, 39106 Magdeburg, Germany
| | - Thomas Neumann
- Department of Neurology, Otto-von-Guericke University Magdeburg, Leipziger Str. 44, 39120 Magdeburg, Germany
- Chair in Health Services Research, School of Life Sciences, University of Siegen, Am Eichenhang 50, 57076 Siegen, Germany
- Chair in Empirical Economics, Otto-von-Guericke-University Magdeburg, Universitätsplatz 2, 39106 Magdeburg, Germany
- Research Campus STIMULATE, Otto-von-Guericke-University Magdeburg, Sandtorstraße 23, 39106 Magdeburg, Germany
| |
Collapse
|
16
|
van Stigt MN, van de Munckhof AAGA, van Meenen LCC, Groenendijk EA, Theunissen M, Franschman G, Smeekes MD, van Grondelle JAF, Geuzebroek G, Siegers A, Marquering HA, Majoie CBLM, Roos YBWEM, Koelman JHTM, Potters WV, Coutinho JM. ELECTRA-STROKE: Electroencephalography controlled triage in the ambulance for acute ischemic stroke—Study protocol for a diagnostic trial. Front Neurol 2022; 13:1018493. [PMID: 36262832 PMCID: PMC9576201 DOI: 10.3389/fneur.2022.1018493] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Accepted: 09/07/2022] [Indexed: 11/13/2022] Open
Abstract
Background Endovascular thrombectomy (EVT) is the standard treatment for large vessel occlusion stroke of the anterior circulation (LVO-a stroke). Approximately half of EVT-eligible patients are initially presented to hospitals that do not offer EVT. Subsequent inter-hospital transfer delays treatment, which negatively affects patients' prognosis. Prehospital identification of patients with LVO-a stroke would allow direct transportation of these patients to an EVT-capable center. Electroencephalography (EEG) may be suitable for this purpose because of its sensitivity to cerebral ischemia. The hypothesis of ELECTRA-STROKE is that dry electrode EEG is feasible for prehospital detection of LVO-a stroke. Methods ELECTRA-STROKE is an investigator-initiated, diagnostic study. EEG recordings will be performed in patients with a suspected stroke in the ambulance. The primary endpoint is the diagnostic accuracy of the theta/alpha ratio for the diagnosis of LVO-a stroke, expressed by the area under the receiver operating characteristic (ROC) curve. EEG recordings will be performed in 386 patients. Discussion If EEG can be used to identify LVO-a stroke patients with sufficiently high diagnostic accuracy, it may enable direct routing of these patients to an EVT-capable center, thereby reducing time-to-treatment and improving patient outcomes. Clinical trial registration ClinicalTrials.gov, identifier: NCT03699397.
Collapse
Affiliation(s)
- Maritta N. van Stigt
- Department of Clinical Neurophysiology, Amsterdam University Medical Centers (UMC) Location University of Amsterdam, Amsterdam, Netherlands
- Department of Neurology, Amsterdam UMC Location University of Amsterdam, Amsterdam, Netherlands
| | - Anita A. G. A. van de Munckhof
- Department of Clinical Neurophysiology, Amsterdam University Medical Centers (UMC) Location University of Amsterdam, Amsterdam, Netherlands
- Department of Neurology, Amsterdam UMC Location University of Amsterdam, Amsterdam, Netherlands
| | - Laura C. C. van Meenen
- Department of Neurology, Amsterdam UMC Location University of Amsterdam, Amsterdam, Netherlands
| | - Eva A. Groenendijk
- Department of Clinical Neurophysiology, Amsterdam University Medical Centers (UMC) Location University of Amsterdam, Amsterdam, Netherlands
- Department of Neurology, Amsterdam UMC Location University of Amsterdam, Amsterdam, Netherlands
| | | | | | | | | | | | | | - Henk A. Marquering
- Department of Biomedical Engineering and Physics, Amsterdam UMC Location University of Amsterdam, Amsterdam, Netherlands
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Amsterdam, Netherlands
| | - Charles B. L. M. Majoie
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Amsterdam, Netherlands
| | - Yvo B. W. E. M. Roos
- Department of Neurology, Amsterdam UMC Location University of Amsterdam, Amsterdam, Netherlands
| | - Johannes H. T. M. Koelman
- Department of Clinical Neurophysiology, Amsterdam University Medical Centers (UMC) Location University of Amsterdam, Amsterdam, Netherlands
| | - Wouter V. Potters
- Department of Clinical Neurophysiology, Amsterdam University Medical Centers (UMC) Location University of Amsterdam, Amsterdam, Netherlands
- Department of Neurology, Amsterdam UMC Location University of Amsterdam, Amsterdam, Netherlands
| | - Jonathan M. Coutinho
- Department of Neurology, Amsterdam UMC Location University of Amsterdam, Amsterdam, Netherlands
- *Correspondence: Jonathan M. Coutinho
| |
Collapse
|
17
|
Dong F, Wu L, Feng Y, Liang D. Research on Movement Intentions of Human's Left and Right Legs Based on EEG Signals. J Med Device 2022. [DOI: 10.1115/1.4055435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Abstract
Active rehabilitation training method can help stroke patients recover better and faster. However, the lower limb rehabilitation robot based on electroencephalogram (EEG) has low recognition accuracy now. A classification method based on EEG signals of motor imagery is proposed to enable patients to accurately control their left and right legs. Firstly, aiming at the unstable characteristics of EEG signals, an experimental protocl of motor imagery was constructed based on multi-joint motion coupling of left and right legs. The signals with time-frequency analysis and ERD/S analysis have proved the reliability and validity of the collected EEG signals. Then, the EEG signals generated by the protocol were preprocessed and Common Space Pattern (CSP) was used to extract their features. Support Vector Machine (SVM) and Linear Discriminant Analysis (LDA) are adapted and their accuracy of classification results are compared. Finally, on the basis of the proposed classifier with excellent performance, the classifier is used in the active control strategy of the lower limb rehabilitation robot, and the experiment verified that the average accuracy of two volunteers in controlling the lower limb rehabilitation robot reached 95.1%. This research provides a good theoretical basis for the realization and application of brain-computer interface in rehabilitation training.
Collapse
Affiliation(s)
- Fangyan Dong
- Ningbo University, No. 818, Fenghua Road, Jiangbei District, Ningbo City, Zhejiang Province, China, 315211 Ningbo
| | - Liangda Wu
- Ningbo University, No. 818, Fenghua Road, Jiangbei District, Ningbo City, Zhejiang Province, China, 315211 Ningbo
| | - Yongfei Feng
- Ningbo University, No. 818, Fenghua Road, Jiangbei District, Ningbo City, Zhejiang Province, China, 315211 Ningbo
| | - Dongtai Liang
- Ningbo University, No. 818, Fenghua Road, Jiangbei District, Ningbo City, Zhejiang Province, China, 315211 Ningbo
| |
Collapse
|
18
|
Guermandi M, Cossettini A, Benatti S, Benini L. A Wireless System for EEG Acquisition and Processing in an Earbud Form Factor with 600 Hours Battery Lifetime. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:3139-3145. [PMID: 36086587 DOI: 10.1109/embc48229.2022.9871874] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In recent years, in-ear electroencephalography (EEG) was demonstrated to record signals of similar quality compared to standard scalp-based EEG, and clinical applications of objective hearing threshold estimations have been reported. Existing devices, however, still lack important features. In fact, most of the available solutions are based on wet electrodes, require to be connected to external acquisition platforms, or do not offer on-board processing capabilities. Here we overcome all these limitations, presenting an ear-EEG system based on dry electrodes that includes all the acquisition, processing, and connectivity electronics directly in the ear bud. The earpiece is equipped with an ultra-low power analog front-end for analog-to-digital conversion, a low-power MEMS microphone, a low-power inertial measurement unit, and an ARM Cortex-M4 based microcontroller enabling on-board processing and Bluetooth Low Energy connectivity. The system can stream raw EEG data or perform data processing directly in-ear. We test the device by analysing its capability to detect brain response to external auditory stimuli, achieving 4 and 1.3 mW power consumption for data streaming or on board processing, respectively. The latter allows for 600 hours operation on a PR44 zinc-air battery. To the best of our knowledge, this is the first wireless and fully self-contained ear-EEG system performing on-board processing, all embedded in a single earbud. Clinical relevance- The proposed ear-EEG system can be employed for diagnostic tasks such as objective hearing threshold estimations, outside of clinical settings, thereby enabling it as a point-of-care solution. The long battery lifetime is also suitable for a continuous monitoring scenario.
Collapse
|
19
|
Arpaia P, Esposito A, Natalizio A, Parvis M. How to successfully classify EEG in motor imagery BCI: a metrological analysis of the state of the art. J Neural Eng 2022; 19. [PMID: 35640554 DOI: 10.1088/1741-2552/ac74e0] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Accepted: 05/31/2022] [Indexed: 11/11/2022]
Abstract
Objective. Processing strategies are analysed with respect to the classification of electroencephalographic signals related to brain-computer interfaces based on motor imagery. A review of literature is carried out to understand the achievements in motor imagery classification, the most promising trends, and the challenges in replicating these results. Main focus is placed on performance by means of a rigorous metrological analysis carried out in compliance with the international vocabulary of metrology. Hence, classification accuracy and its uncertainty are considered, as well as repeatability and reproducibility.Approach. The paper works included in the review concern the classification of electroencephalographic signals in motor-imagery- based brain-computer interfaces. Article search was carried out in accordance with the PRISMA standard and 89 studies were included.Main results. Statistically-based analyses show that brain-inspired approaches are increasingly proposed, and that these are particularly successful in discriminating against multiple classes. Notably, many proposals involve convolutional neural networks. Instead, classical machine learning approaches are still effective for binary classifications. Many proposals combine common spatial pattern, least absolute shrinkage and selection operator, and support vector machines. Regarding reported classification accuracies, performance above the upper quartile is in the 85 % to 100 % range for the binary case and in the 83 % to 93 % range for multi-class one. Associated uncertainties are up to 6 % while repeatability for a predetermined dataset is up to 8 %. Reproducibility assessment was instead prevented by lack of standardization in experiments.Significance. By relying on the analysed studies, the reader is guided towards the development of a successful processing strategy as a crucial part of a brain-computer interface. Moreover, it is suggested that future studies should extend these approaches on data from more subjects and with custom experiments, even by investigating online operation. This would also enable the quantification of results reproducibility.
Collapse
Affiliation(s)
- Pasquale Arpaia
- Centro Interdipartimentale di Ricerca in Management Sanitario e Innovazione in Sanità, Università degli Studi di Napoli Federico II, Via Claudio, 21, Napoli, Campania, 80125, ITALY
| | - Antonio Esposito
- Department of Electronics and Telecommunications (DET), Politecnico di Torino, Corso Castelfidardo, 39, Torino, 10129, ITALY
| | - Angela Natalizio
- Department of Electronics and Telecommunications (DET), Politecnico di Torino, Corso Castelfidardo, 39, Torino, Piemonte, 10129, ITALY
| | - Marco Parvis
- Department of Electronics and Telecommunications (DET), Politecnico di Torino, Corso Castelfidardo, 39, Torino, Piemonte, 10129, ITALY
| |
Collapse
|
20
|
Cho S, Chang T, Yu T, Lee CH. Smart Electronic Textiles for Wearable Sensing and Display. BIOSENSORS 2022; 12:bios12040222. [PMID: 35448282 PMCID: PMC9029731 DOI: 10.3390/bios12040222] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 04/04/2022] [Accepted: 04/06/2022] [Indexed: 05/13/2023]
Abstract
Increasing demand of using everyday clothing in wearable sensing and display has synergistically advanced the field of electronic textiles, or e-textiles. A variety of types of e-textiles have been formed into stretchy fabrics in a manner that can maintain their intrinsic properties of stretchability, breathability, and wearability to fit comfortably across different sizes and shapes of the human body. These unique features have been leveraged to ensure accuracy in capturing physical, chemical, and electrophysiological signals from the skin under ambulatory conditions, while also displaying the sensing data or other immediate information in daily life. Here, we review the emerging trends and recent advances in e-textiles in wearable sensing and display, with a focus on their materials, constructions, and implementations. We also describe perspectives on the remaining challenges of e-textiles to guide future research directions toward wider adoption in practice.
Collapse
Affiliation(s)
- Seungse Cho
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA;
| | - Taehoo Chang
- School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA;
| | - Tianhao Yu
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA;
| | - Chi Hwan Lee
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA;
- School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA;
- School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA;
- Center for Implantable Devices, Purdue University, West Lafayette, IN 47907, USA
- Correspondence:
| |
Collapse
|
21
|
Pei W, Wu X, Zhang X, Zha A, Tian S, Wang Y, Gao X. A Pre-gelled EEG Electrode and Its Application in SSVEP-based BCI. IEEE Trans Neural Syst Rehabil Eng 2022; 30:843-850. [PMID: 35324444 DOI: 10.1109/tnsre.2022.3161989] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Electroencephalogram (EEG) electrodes are critical devices for brain-computer interface and neurofeedback. A pre-gelled (PreG) electrode was developed in this paper for EEG signal acquisition with a short installation time and good comfort. A hydrogel probe was placed in advance on the Ag/AgCl electrode before wearing the EEG headband instead of a time-consuming gel injection after wearing the headband. The impedance characteristics were compared between the PreG electrode and the wet electrode. The PreG electrode and the wet electrode performed the Brain-Computer Interface (BCI) application experiment to evaluate their performance. The average impedance of the PreG electrode can be decreased to 43 kΩ or even lower, which is higher than the wet electrode with an impedance of 8 kΩ. However, there is no significant difference in classification accuracy and information transmission rate (ITR) between the PreG electrode and the wet electrode in a 40 target BCI system based on Steady State Visually Evoked Potential (SSVEP). This study validated the efficiency of the proposed PreG electrode in the SSVEP-based BCI. The proposed PreG electrode will be an excellent substitute for wet electrodes in an actual application with convenience and good comfort.
Collapse
|
22
|
EEG spectral exponent as a synthetic index for the longitudinal assessment of stroke recovery. Clin Neurophysiol 2022; 137:92-101. [PMID: 35303540 PMCID: PMC9038588 DOI: 10.1016/j.clinph.2022.02.022] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 01/02/2022] [Accepted: 02/22/2022] [Indexed: 12/20/2022]
Abstract
The Spectral Exponent (SE) indexes power-law features of the resting EEG in stroke patients. SE is consistently steeper in the affected hemisphere of patients after middle cerebral artery stroke. SE is linked to clinical status and seems to be a good predictor of clinical outcome.
Objective Quantitative Electroencephalography (qEEG) can capture changes in brain activity following stroke. qEEG metrics traditionally focus on oscillatory activity, however recent findings highlight the importance of aperiodic (power-law) structure in characterizing pathological brain states. We assessed neurophysiological alterations and recovery after mono-hemispheric stroke by means of the Spectral Exponent (SE), a metric that reflects EEG slowing and quantifies the power-law decay of the EEG Power Spectral Density (PSD). Methods Eighteen patients (n = 18) with mild to moderate mono-hemispheric Middle Cerebral Artery (MCA) ischaemic stroke were retrospectively enrolled for this study. Patients underwent EEG recording in the sub-acute phase (T0) and after 2 months of physical rehabilitation (T1). Sixteen healthy controls (HC; n = 16) matched by age and sex were enrolled as a normative group. SE values and narrow-band PSD were estimated for each recording. We compared SE and band-power between patients and HC, and between the affected (AH) and unaffected hemisphere (UH) at T0 and T1 in patients. Results At T0, stroke patients showed significantly more negative SE values than HC (p = 0.003), reflecting broad-band EEG slowing. Most important, in patients SE over the AH was consistently more negative compared to the UH and showed a renormalization at T1. This SE renormalization significantly correlated with National Institute of Health Stroke Scale (NIHSS) improvement (R = 0.63, p = 0.005). Conclusions SE is a reliable readout of the neurophysiological and clinical alterations occurring after an ischaemic cortical lesion. Significance SE promise to be a robust method to monitor and predict patients’ functional outcome.
Collapse
|
23
|
Niu X, Wang L, Li H, Wang T, Liu H, He Y. Fructus Xanthii-Inspired Low Dynamic Noise Dry Bioelectrodes for Surface Monitoring of ECG. ACS APPLIED MATERIALS & INTERFACES 2022; 14:6028-6038. [PMID: 35044157 DOI: 10.1021/acsami.1c22303] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The microstructured surfaces of bioelectrical dry electrodes are important aspects of dry electrode design. However, traditional surfaces for microstructured bioelectrical dry electrodes are costly to produce and require complex fabrication methods. In this study, a novel stacked-template method is proposed for the first time, rapidly producing microstructured dry electrodes at a low cost and with a large surface area. Three types of microstructured Ag/AgCl thermoplastic polyurethane (TPU) electrodes with a Fructus xanthii-inspired barb structure (FXbs) are prepared using this method; then, the dynamic friction, hair interference resistance, electrochemical, and electrocardiogram (ECG) signal acquisition performance of the electrodes are tested, and the dynamic noise characteristics of the electrodes are comprehensively evaluated with simulated instruments. Compared to the plate structure, the dynamic friction coefficient of the FXbs electrode improved by about 38.8%, exhibiting strong hair interference resistance. In addition, the FXbs electrode exhibits low dynamic noise and comparable performance to the wet electrode, in terms of signal acquisition, when it is tested using simulated instruments. Therefore, the prepared FXbs electrode increases the friction coefficient between the electrode and the skin, which effectively resolves issues related to dynamic noise in bioelectrical signals, making it suitable for dynamic measurements.
Collapse
Affiliation(s)
- Xin Niu
- School of Textile Science and Engineering, Institute of Smart Wearable Electronic Textiles, Tiangong University, Tianjin 300387, P. R. China
| | - Lingzhu Wang
- School of Textile Science and Engineering, Institute of Smart Wearable Electronic Textiles, Tiangong University, Tianjin 300387, P. R. China
| | - Hui Li
- School of Textile Science and Engineering, Institute of Smart Wearable Electronic Textiles, Tiangong University, Tianjin 300387, P. R. China
| | - Tanyu Wang
- School of Textile Science and Engineering, Institute of Smart Wearable Electronic Textiles, Tiangong University, Tianjin 300387, P. R. China
| | - Hao Liu
- School of Textile Science and Engineering, Institute of Smart Wearable Electronic Textiles, Tiangong University, Tianjin 300387, P. R. China
| | - Yin He
- School of Textile Science and Engineering, Institute of Smart Wearable Electronic Textiles, Tiangong University, Tianjin 300387, P. R. China
| |
Collapse
|
24
|
Comani S, Bertollo M, Haueisen J. Editorial: Dry Electroencephalography for Brain Monitoring in Sports and Movement Science. Front Neurosci 2021; 15:809227. [PMID: 34924948 PMCID: PMC8674687 DOI: 10.3389/fnins.2021.809227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Accepted: 11/18/2021] [Indexed: 11/23/2022] Open
Affiliation(s)
- Silvia Comani
- Behavioral Imaging and Neural Dynamics Center, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.,Department of Neurosciences, Imaging and Clinical Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Maurizio Bertollo
- Behavioral Imaging and Neural Dynamics Center, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.,Department of Medicine and Aging Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany.,Department of Neurology, Biomagnetic Center, Jena University Hospital, Jena, Germany
| |
Collapse
|
25
|
Me-Doped Ti-Me Intermetallic Thin Films Used for Dry Biopotential Electrodes: A Comparative Case Study. SENSORS 2021; 21:s21238143. [PMID: 34884159 PMCID: PMC8662430 DOI: 10.3390/s21238143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 11/26/2021] [Accepted: 12/01/2021] [Indexed: 11/23/2022]
Abstract
In a new era for digital health, dry electrodes for biopotential measurement enable the monitoring of essential vital functions outside of specialized healthcare centers. In this paper, a new type of nanostructured titanium-based thin film is proposed, revealing improved biopotential sensing performance and overcoming several of the limitations of conventional gel-based electrodes such as reusability, durability, biocompatibility, and comfort. The thin films were deposited on stainless steel (SS) discs and polyurethane (PU) substrates to be used as dry electrodes, for non-invasive monitoring of body surface biopotentials. Four different Ti–Me (Me = Al, Cu, Ag, or Au) metallic binary systems were prepared by magnetron sputtering. The morphology of the resulting Ti–Me systems was found to be dependent on the chemical composition of the films, specifically on the type and amount of Me. The existence of crystalline intermetallic phases or glassy amorphous structures also revealed a strong influence on the morphological features developed by the different systems. The electrodes were tested in an in-vivo study on 20 volunteers during sports activity, allowing study of the application-specific characteristics of the dry electrodes, based on Ti–Me intermetallic thin films, and evaluation of the impact of the electrode–skin impedance on biopotential sensing. The electrode–skin impedance results support the reusability and the high degree of reliability of the Ti–Me dry electrodes. The Ti–Al films revealed the least performance as biopotential electrodes, while the Ti–Au system provided excellent results very close to the Ag/AgCl reference electrodes.
Collapse
|
26
|
Fiedler P, Fonseca C, Supriyanto E, Zanow F, Haueisen J. A high-density 256-channel cap for dry electroencephalography. Hum Brain Mapp 2021; 43:1295-1308. [PMID: 34796574 PMCID: PMC8837591 DOI: 10.1002/hbm.25721] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 10/29/2021] [Accepted: 11/08/2021] [Indexed: 11/09/2022] Open
Abstract
High‐density electroencephalography (HD‐EEG) is currently limited to laboratory environments since state‐of‐the‐art electrode caps require skilled staff and extensive preparation. We propose and evaluate a 256‐channel cap with dry multipin electrodes for HD‐EEG. We describe the designs of the dry electrodes made from polyurethane and coated with Ag/AgCl. We compare in a study with 30 volunteers the novel dry HD‐EEG cap to a conventional gel‐based cap for electrode‐skin impedances, resting state EEG, and visual evoked potentials (VEP). We perform wearing tests with eight electrodes mimicking cap applications on real human and artificial skin. Average impedances below 900 kΩ for 252 out of 256 dry electrodes enables recording with state‐of‐the‐art EEG amplifiers. For the dry EEG cap, we obtained a channel reliability of 84% and a reduction of the preparation time of 69%. After exclusion of an average of 16% (dry) and 3% (gel‐based) bad channels, resting state EEG, alpha activity, and pattern reversal VEP can be recorded with less than 5% significant differences in all compared signal characteristics metrics. Volunteers reported wearing comfort of 3.6 ± 1.5 and 4.0 ± 1.8 for the dry and 2.5 ± 1.0 and 3.0 ± 1.1 for the gel‐based cap prior and after the EEG recordings, respectively (scale 1–10). Wearing tests indicated that up to 3,200 applications are possible for the dry electrodes. The 256‐channel HD‐EEG dry electrode cap overcomes the principal limitations of HD‐EEG regarding preparation complexity and allows rapid application by not medically trained persons, enabling new use cases for HD‐EEG.
Collapse
Affiliation(s)
- Patrique Fiedler
- Institute of Biomedical Engineering and Informatics, Technische Universität IlmenauIlmenauGermany
| | - Carlos Fonseca
- Faculdade de Engenharia, Departamento de Engenharia Metalúrgica e de MateriaisUniversidade do PortoPortoPortugal
- LAETA/INEGI, Institute of Science and Innovation in Mechanical and Industrial EngineeringPortoPortugal
| | - Eko Supriyanto
- IJN‐UTM Cardiovascular Engineering Centre, Universiti Teknologi MalaysiaJohor BahruMalaysia
| | - Frank Zanow
- eemagine Medical Imaging Solutions GmbHBerlinGermany
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics, Technische Universität IlmenauIlmenauGermany
- Department of NeurologyBiomagnetic Center, University Hospital JenaJenaGermany
| |
Collapse
|
27
|
Vasconcelos B, Fiedler P, Machts R, Haueisen J, Fonseca C. The Arch Electrode: A Novel Dry Electrode Concept for Improved Wearing Comfort. Front Neurosci 2021; 15:748100. [PMID: 34733134 PMCID: PMC8558300 DOI: 10.3389/fnins.2021.748100] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 09/27/2021] [Indexed: 11/27/2022] Open
Abstract
Electroencephalography (EEG) is increasingly used for repetitive and prolonged applications like neurofeedback, brain computer interfacing, and long-term intermittent monitoring. Dry-contact electrodes enable rapid self-application. A common drawback of existing dry electrodes is the limited wearing comfort during prolonged application. We propose a novel dry Arch electrode. Five semi-circular arches are arranged parallelly on a common baseplate. The electrode substrate material is a flexible thermoplastic polyurethane (TPU) produced by additive manufacturing. A chemical coating of Silver/Silver-Chloride (Ag/AgCl) is applied by electroless plating using a novel surface functionalization method. Arch electrodes were manufactured and validated in terms of mechanical durability, electrochemical stability, in vivo applicability, and signal characteristics. We compare the results of the dry arch electrodes with dry pin-shaped and conventional gel-based electrodes. 21-channel EEG recordings were acquired on 10 male and 5 female volunteers. The tests included resting state EEG, alpha activity, and a visual evoked potential. Wearing comfort was rated by the subjects directly after application, as well as at 30 min and 60 min of wearing. Our results show that the novel plating technique provides a well-adhering electrically conductive and electrochemically stable coating, withstanding repetitive strain and bending tests. The signal quality of the Arch electrodes is comparable to pin-shaped dry electrodes. The average channel reliability of the Arch electrode setup was 91.9 ± 9.5%. No considerable differences in signal characteristics have been observed for the gel-based, dry pin-shaped, and arch-shaped electrodes after the identification and exclusion of bad channels. The comfort was improved in comparison to pin-shaped electrodes and enabled applications of over 60 min duration. Arch electrodes required individual adaptation of the electrodes to the orientation and hairstyle of the volunteers. This initial preparation time of the 21-channel cap increased from an average of 5 min for pin-like electrodes to 15 min for Arch electrodes and 22 min for gel-based electrodes. However, when re-applying the arch electrode cap on the same volunteer, preparation times of pin-shaped and arch-shaped electrodes were comparable. In summary, our results indicate the applicability of the novel Arch electrode and coating for EEG acquisition. The novel electrode enables increased comfort for prolonged dry-contact measurement.
Collapse
Affiliation(s)
- Beatriz Vasconcelos
- Departamento de Engenharia Metalúrgica e de Materiais, Faculdade de Engenharia, Universidade do Porto, Porto, Portugal.,CEMUC - Department of Mechanical Engineering, University of Coimbra, Coimbra, Portugal
| | - Patrique Fiedler
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany
| | - René Machts
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany.,Department of Neurology, Biomagnetic Center, Jena University Hospital, Jena, Germany
| | - Carlos Fonseca
- Departamento de Engenharia Metalúrgica e de Materiais, Faculdade de Engenharia, Universidade do Porto, Porto, Portugal.,LAETA/INEGI, Institute of Science and Innovation in Mechanical and Industrial Engineering, Porto, Portugal
| |
Collapse
|
28
|
Heijs JJ, Havelaar RJ, Fiedler P, van Wezel RJ, Heida T. Validation of Soft Multipin Dry EEG Electrodes. SENSORS 2021; 21:s21206827. [PMID: 34696039 PMCID: PMC8541549 DOI: 10.3390/s21206827] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 10/09/2021] [Accepted: 10/11/2021] [Indexed: 11/28/2022]
Abstract
Current developments towards multipin, dry electrodes in electroencephalography (EEG) are promising for applications in non-laboratory environments. Dry electrodes do not require the application of conductive gel, which mostly confines the use of gel EEG systems to the laboratory environment. The aim of this study is to validate soft, multipin, dry EEG electrodes by comparing their performance to conventional gel EEG electrodes. Fifteen healthy volunteers performed three tasks, with a 32-channel gel EEG system and a 32-channel dry EEG system: the 40 Hz Auditory Steady-State Response (ASSR), the checkerboard paradigm, and an eyes open/closed task. Within-subject analyses were performed to compare the signal quality in the time, frequency, and spatial domains. The results showed strong similarities between the two systems in the time and frequency domains, with strong correlations of the visual (ρ = 0.89) and auditory evoked potential (ρ = 0.81), and moderate to strong correlations for the alpha band during eye closure (ρ = 0.81–0.86) and the 40 Hz-ASSR power (ρ = 0.66–0.72), respectively. However, delta and theta band power was significantly increased, and the signal-to-noise ratio was significantly decreased for the dry EEG system. Topographical distributions were comparable for both systems. Moreover, the application time of the dry EEG system was significantly shorter (8 min). It can be concluded that the soft, multipin dry EEG system can be used in brain activity research with similar accuracy as conventional gel electrodes.
Collapse
Affiliation(s)
- Janne J.A. Heijs
- TechMed Centre, Department of Biomedical Signals and Systems, University of Twente, 7522 NB Enschede, The Netherlands; or (T.H.)
- Correspondence:
| | - Ruben Jan Havelaar
- Donders Centre for Neuroscience, Department of Biophysics, Radboud University, 6525 AJ Nijmegen, The Netherlands;
| | - Patrique Fiedler
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany;
| | - Richard J.A. van Wezel
- TechMed Centre, Department of Biomedical Signals and Systems, University of Twente, 7522 NB Enschede, The Netherlands; or (T.H.)
- Donders Centre for Neuroscience, Department of Biophysics, Radboud University, 6525 AJ Nijmegen, The Netherlands;
| | - Tjitske Heida
- TechMed Centre, Department of Biomedical Signals and Systems, University of Twente, 7522 NB Enschede, The Netherlands; or (T.H.)
| |
Collapse
|
29
|
van Meenen LCC, van Stigt MN, Marquering HA, Majoie CBLM, Roos YBWEM, Koelman JHTM, Potters WV, Coutinho JM. Detection of large vessel occlusion stroke with electroencephalography in the emergency room: first results of the ELECTRA-STROKE study. J Neurol 2021; 269:2030-2038. [PMID: 34476587 PMCID: PMC8412867 DOI: 10.1007/s00415-021-10781-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 08/27/2021] [Accepted: 08/27/2021] [Indexed: 11/27/2022]
Abstract
Background Prehospital detection of large vessel occlusion stroke of the anterior circulation (LVO-a) would enable direct transportation of these patients to an endovascular thrombectomy (EVT) capable hospital. The ongoing ELECTRA-STROKE study investigates the diagnostic accuracy of dry electrode electroencephalography (EEG) for LVO-a stroke in the prehospital setting. To determine which EEG features are most useful for this purpose and assess EEG data quality, EEG recordings are also performed in the emergency room (ER). Here, we report data of the first 100 patients included in the ER. Methods Patients presented to the ER with a suspected stroke or known LVO-a stroke underwent a single EEG prior to EVT. Diagnostic accuracy for LVO-a stroke of frequency band power, brain symmetry and phase synchronization measures were evaluated by calculating receiver operating characteristic curves. Optimal cut-offs were determined as the highest sensitivity at a specificity of ≥ 80%. Results EEG data were of sufficient quality for analysis in 65/100 included patients. Of these, 35/65 (54%) had an acute ischemic stroke, of whom 9/65 (14%) had an LVO-a stroke. Median onset-to-EEG-time was 266 min (IQR 121–655) and median EEG-recording-time was 3 min (IQR 3–5). The EEG feature with the highest diagnostic accuracy for LVO-a stroke was theta–alpha ratio (AUC 0.83; sensitivity 75%; specificity 81%). Combined, weighted phase lag index and relative theta power best identified LVO-a stroke (sensitivity 100%; specificity 84%). Conclusion Dry electrode EEG is a promising tool for LVO-a stroke detection, but data quality needs to be improved and validation in the prehospital setting is necessary. (TRN: NCT03699397, registered October 9 2018). Supplementary Information The online version contains supplementary material available at 10.1007/s00415-021-10781-6.
Collapse
Affiliation(s)
- Laura C C van Meenen
- Department of Neurology, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105AZ, Amsterdam, The Netherlands
| | - Maritta N van Stigt
- Department of Clinical Neurophysiology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Henk A Marquering
- Department of Biomedical Engineering and Physics, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Charles B L M Majoie
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Yvo B W E M Roos
- Department of Neurology, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105AZ, Amsterdam, The Netherlands
| | - Johannes H T M Koelman
- Department of Neurology, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105AZ, Amsterdam, The Netherlands
- Department of Clinical Neurophysiology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Wouter V Potters
- Department of Neurology, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105AZ, Amsterdam, The Netherlands
- Department of Clinical Neurophysiology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Jonathan M Coutinho
- Department of Neurology, Amsterdam UMC, University of Amsterdam, Meibergdreef 9, 1105AZ, Amsterdam, The Netherlands.
| |
Collapse
|
30
|
Beltrachini L, von Ellenrieder N, Eichardt R, Haueisen J. Optimal design of on-scalp electromagnetic sensor arrays for brain source localisation. Hum Brain Mapp 2021; 42:4869-4879. [PMID: 34245061 PMCID: PMC8449117 DOI: 10.1002/hbm.25586] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 06/09/2021] [Accepted: 06/25/2021] [Indexed: 11/11/2022] Open
Abstract
Optically pumped magnetometers (OPMs) are quickly widening the scopes of noninvasive neurophysiological imaging. The possibility of placing these magnetic field sensors on the scalp allows not only to acquire signals from people in movement, but also to reduce the distance between the sensors and the brain, with a consequent gain in the signal‐to‐noise ratio. These advantages make the technique particularly attractive to characterise sources of brain activity in demanding populations, such as children and patients with epilepsy. However, the technology is currently in an early stage, presenting new design challenges around the optimal sensor arrangement and their complementarity with other techniques as electroencephalography (EEG). In this article, we present an optimal array design strategy focussed on minimising the brain source localisation error. The methodology is based on the Cramér‐Rao bound, which provides lower error bounds on the estimation of source parameters regardless of the algorithm used. We utilise this framework to compare whole head OPM arrays with commercially available electro/magnetoencephalography (E/MEG) systems for localising brain signal generators. In addition, we study the complementarity between EEG and OPM‐based MEG, and design optimal whole head systems based on OPMs only and a combination of OPMs and EEG electrodes for characterising deep and superficial sources alike. Finally, we show the usefulness of the approach to find the nearly optimal sensor positions minimising the estimation error bound in a given cortical region when a limited number of OPMs are available. This is of special interest for maximising the performance of small scale systems to ad hoc neurophysiological experiments, a common situation arising in most OPM labs.
Collapse
Affiliation(s)
- Leandro Beltrachini
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Physics and Astronomy, Cardiff University, Cardiff
| | | | - Roland Eichardt
- Institute of Biomedical Engineering and Informatics, Ilmenau University of Technology, Ilmenau, Germany
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics, Ilmenau University of Technology, Ilmenau, Germany
| |
Collapse
|
31
|
van Meenen LCC, van Stigt MN, Siegers A, Smeekes MD, van Grondelle JAF, Geuzebroek G, Marquering HA, Majoie CBLM, Roos YBWEM, Koelman JHTM, Potters WV, Coutinho JM. Detection of Large Vessel Occlusion Stroke in the Prehospital Setting: Electroencephalography as a Potential Triage Instrument. Stroke 2021; 52:e347-e355. [PMID: 33940955 DOI: 10.1161/strokeaha.120.033053] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A reliable and fast instrument for prehospital detection of large vessel occlusion (LVO) stroke would be a game-changer in stroke care, because it would enable direct transportation of LVO stroke patients to the nearest comprehensive stroke center for endovascular treatment. This strategy would substantially improve treatment times and thus clinical outcomes of patients. Here, we outline our view on the requirements of an effective prehospital LVO detection method, namely: high diagnostic accuracy; fast application and interpretation; user-friendliness; compactness; and low costs. We argue that existing methods for prehospital LVO detection, including clinical scales, mobile stroke units and transcranial Doppler, do not fulfill all criteria, hindering broad implementation of these methods. Instead, electroencephalography may be suitable for prehospital LVO detection since in-hospital studies have shown that quantification of hypoxia-induced changes in the electroencephalography signal have good diagnostic accuracy for LVO stroke. Although performing electroencephalography measurements in the prehospital setting comes with challenges, solutions for fast and simple application of this method are available. Currently, the feasibility and diagnostic accuracy of electroencephalography in the prehospital setting are being investigated in clinical trials.
Collapse
Affiliation(s)
- Laura C C van Meenen
- Department of Neurology (L.C.C.v.M., Y.B.W.E.M.R., W.V.P., J.M.C.), Amsterdam UMC, University of Amsterdam, the Netherlands
| | - Maritta N van Stigt
- Department of Clinical Neurophysiology (M.N.v.S., J.H.T.M.K., W.V.P.), Amsterdam UMC, University of Amsterdam, the Netherlands
| | - Arjen Siegers
- Ambulance Amsterdam, Amsterdam, the Netherlands (A.S., J.A.F.v.G., G.G.)
| | - Martin D Smeekes
- Emergency Medical Services North-Holland North, Alkmaar, the Netherlands (M.D.S.)
| | | | - Geertje Geuzebroek
- Ambulance Amsterdam, Amsterdam, the Netherlands (A.S., J.A.F.v.G., G.G.)
| | - Henk A Marquering
- Department of Biomedical Engineering and Physics (H.A.M.), Amsterdam UMC, University of Amsterdam, the Netherlands.,Department of Radiology and Nuclear Medicine (H.A.M., C.B.L.M.M.), Amsterdam UMC, University of Amsterdam, the Netherlands
| | - Charles B L M Majoie
- Department of Radiology and Nuclear Medicine (H.A.M., C.B.L.M.M.), Amsterdam UMC, University of Amsterdam, the Netherlands
| | - Yvo B W E M Roos
- Department of Neurology (L.C.C.v.M., Y.B.W.E.M.R., W.V.P., J.M.C.), Amsterdam UMC, University of Amsterdam, the Netherlands
| | - Johannes H T M Koelman
- Department of Clinical Neurophysiology (M.N.v.S., J.H.T.M.K., W.V.P.), Amsterdam UMC, University of Amsterdam, the Netherlands
| | - Wouter V Potters
- Department of Neurology (L.C.C.v.M., Y.B.W.E.M.R., W.V.P., J.M.C.), Amsterdam UMC, University of Amsterdam, the Netherlands.,Department of Clinical Neurophysiology (M.N.v.S., J.H.T.M.K., W.V.P.), Amsterdam UMC, University of Amsterdam, the Netherlands
| | - Jonathan M Coutinho
- Department of Neurology (L.C.C.v.M., Y.B.W.E.M.R., W.V.P., J.M.C.), Amsterdam UMC, University of Amsterdam, the Netherlands
| |
Collapse
|
32
|
Li G, Wang S, Li M, Duan YY. Towards real-life EEG applications: novel superporous hydrogel-based semi-dry EEG electrodes enabling automatically "charge-discharge" electrolyte. J Neural Eng 2021; 18. [PMID: 33721854 DOI: 10.1088/1741-2552/abeeab] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Accepted: 03/15/2021] [Indexed: 12/22/2022]
Abstract
A novel polyacrylamide/polyvinyl alcohol superporous hydrogel (PAAm/PVA SPH)-based semi-dry electrode was constructed for capturing EEG signals at the hairy scalp, showing automatically "charge-discharge" electrolyte concept in EEG electrode development. In this regard, PAAm/PVA SPH was polymerized in-situ in the hollow electrode cavity by freezing polymerization, which acted as a dynamic reservoir of electrolyte fluid. The superporous hydrogel can be completely "charged" with electrolyte fluid, such as saline, in just a few seconds and can be "discharged" through a few tiny pillars into the scalp at a desirable rate. In this way, an ideal local skin hydration effect was achieved at electrode-skin contact sites, facilitating the bioelectrical signal pathway and significantly reducing electrode-skin impedance. Moreover, the electrode interface effectively avoids short circuit and inconvenient issues. The results show that the semi-dry electrode displayed low and stable contact impedance, showing non-polarization properties with low off-set potential and negligible potential drift. The average temporal cross-correlation coefficient between the semi-dry and conventional wet electrodes was 0.941. Frequency spectra also showed almost identical responses with anticipated neural electrophysiology responses. Considering prominent advantages such as a rapid setup, robust signal, and user-friendliness, the new concept of semi-dry electrodes shows excellent potential in emerging real-life EEG applications.
Collapse
Affiliation(s)
- Guangli Li
- College of Life Sciences and Chemistry, Hunan University of Technology, Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou 412007, China, Zhuzhou, 412008, CHINA
| | - Sizhe Wang
- Wuhan NEO Energy Materials Enterprises Ltd.,, Wuhan NEO Energy Materials Enterprises Ltd., Wuhan 430074, China, Wuhan, Hubei Province, 430074, CHINA
| | - Mingzhe Li
- Wuhan Greentek Pty. Ltd., Wuhan Greentek Pty. Ltd., Wuhan 430074, China, Wuhan, Hubei Province, 430074, CHINA
| | - Yanwen Y Duan
- Wuhan Greentek Pty. Ltd., Wuhan Greentek Pty. Ltd., Wuhan 430074, China, Wuhan, Hubei Province, 430074, CHINA
| |
Collapse
|
33
|
Tanaka S. Mirror Neuron Activity During Audiovisual Appreciation of Opera Performance. Front Psychol 2021; 11:563031. [PMID: 33584402 PMCID: PMC7873040 DOI: 10.3389/fpsyg.2020.563031] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Accepted: 12/14/2020] [Indexed: 02/03/2023] Open
Abstract
Opera is a performing art in which music plays the leading role, and the acting of singers has a synergistic effect with the music. The mirror neuron system represents the neurophysiological mechanism underlying the coupling of perception and action. Mirror neuron activity is modulated by the appropriateness of actions and clarity of intentions, as well as emotional expression and aesthetic values. Therefore, it would be reasonable to assume that an opera performance induces mirror neuron activity in the audience so that the performer effectively shares an embodied performance with the audience. However, it is uncertain which aspect of opera performance induces mirror neuron activity. It is hypothesized that although auditory stimuli could induce mirror neuron activity, audiovisual perception of stage performance is the primary inducer of mirror neuron activity. To test this hypothesis, this study sought to correlate opera performance with brain activity as measured by electroencephalography (EEG) in singers while watching an opera performance with sounds or while listening to an aria without visual stimulus. We detected mirror neuron activity by observing that the EEG power in the alpha frequency band (8-13 Hz) was selectively decreased in the frontal-central-parietal area when watching an opera performance. In the auditory condition, however, the alpha-band power did not change relative to the resting condition. This study illustrates that the audiovisual perception of an opera performance engages the mirror neuron system in its audience.
Collapse
Affiliation(s)
- Shoji Tanaka
- Department of Information and Communication Sciences, Sophia University, Tokyo, Japan
| |
Collapse
|
34
|
Tamburro G, Croce P, Zappasodi F, Comani S. Is Brain Dynamics Preserved in the EEG After Automated Artifact Removal? A Validation of the Fingerprint Method and the Automatic Removal of Cardiac Interference Approach Based on Microstate Analysis. Front Neurosci 2021; 14:577160. [PMID: 33510607 PMCID: PMC7835728 DOI: 10.3389/fnins.2020.577160] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Accepted: 12/10/2020] [Indexed: 12/13/2022] Open
Abstract
The assessment of a method for removing artifacts from electroencephalography (EEG) datasets often disregard verifying that global brain dynamics is preserved. In this study, we verified that the recently introduced optimized fingerprint method and the automatic removal of cardiac interference (ARCI) approach not only remove physiological artifacts from EEG recordings but also preserve global brain dynamics, as assessed with a new approach based on microstate analysis. We recorded EEG activity with a high-resolution EEG system during two resting-state conditions (eyes open, 25 volunteers, and eyes closed, 26 volunteers) known to exhibit different brain dynamics. After signal decomposition by independent component analysis (ICA), the independent components (ICs) related to eyeblinks, eye movements, myogenic interference, and cardiac electromechanical activity were identified with the optimized fingerprint method and ARCI approach and statistically compared with the outcome of the expert classification of the ICs by visual inspection. Brain dynamics in two different groups of denoised EEG signals, reconstructed after having removed the artifactual ICs identified by either visual inspection or the automated methods, was assessed by calculating microstate topographies, microstate metrics (duration, occurrence, and coverage), and directional predominance (based on transition probabilities). No statistically significant differences between the expert and the automated classification of the artifactual ICs were found (p > 0.05). Cronbach’s α values assessed the high test–retest reliability of microstate parameters for EEG datasets denoised by the automated procedure. The total EEG signal variance explained by the sets of global microstate templates was about 80% for all denoised EEG datasets, with no significant differences between groups. For the differently denoised EEG datasets in the two recording conditions, we found that the global microstate templates and the sequences of global microstates were very similar (p < 0.01). Descriptive statistics and Cronbach’s α of microstate metrics highlighted no significant differences and excellent consistency between groups (p > 0.5). These results confirm the ability of the optimized fingerprint method and the ARCI approach to effectively remove physiological artifacts from EEG recordings while preserving global brain dynamics. They also suggest that microstate analysis could represent a novel approach for assessing the ability of an EEG denoising method to remove artifacts without altering brain dynamics.
Collapse
Affiliation(s)
- Gabriella Tamburro
- Department of Neuroscience, Imaging and Clinical Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.,BIND-Behavioral Imaging and Neural Dynamics Center, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Pierpaolo Croce
- Department of Neuroscience, Imaging and Clinical Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Filippo Zappasodi
- Department of Neuroscience, Imaging and Clinical Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.,Institute for Advanced Biomedical Technologies, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Silvia Comani
- Department of Neuroscience, Imaging and Clinical Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.,BIND-Behavioral Imaging and Neural Dynamics Center, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| |
Collapse
|
35
|
Campanella S, Arikan K, Babiloni C, Balconi M, Bertollo M, Betti V, Bianchi L, Brunovsky M, Buttinelli C, Comani S, Di Lorenzo G, Dumalin D, Escera C, Fallgatter A, Fisher D, Giordano GM, Guntekin B, Imperatori C, Ishii R, Kajosch H, Kiang M, López-Caneda E, Missonnier P, Mucci A, Olbrich S, Otte G, Perrottelli A, Pizzuti A, Pinal D, Salisbury D, Tang Y, Tisei P, Wang J, Winkler I, Yuan J, Pogarell O. Special Report on the Impact of the COVID-19 Pandemic on Clinical EEG and Research and Consensus Recommendations for the Safe Use of EEG. Clin EEG Neurosci 2021; 52:3-28. [PMID: 32975150 PMCID: PMC8121213 DOI: 10.1177/1550059420954054] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
INTRODUCTION The global COVID-19 pandemic has affected the economy, daily life, and mental/physical health. The latter includes the use of electroencephalography (EEG) in clinical practice and research. We report a survey of the impact of COVID-19 on the use of clinical EEG in practice and research in several countries, and the recommendations of an international panel of experts for the safe application of EEG during and after this pandemic. METHODS Fifteen clinicians from 8 different countries and 25 researchers from 13 different countries reported the impact of COVID-19 on their EEG activities, the procedures implemented in response to the COVID-19 pandemic, and precautions planned or already implemented during the reopening of EEG activities. RESULTS Of the 15 clinical centers responding, 11 reported a total stoppage of all EEG activities, while 4 reduced the number of tests per day. In research settings, all 25 laboratories reported a complete stoppage of activity, with 7 laboratories reopening to some extent since initial closure. In both settings, recommended precautions for restarting or continuing EEG recording included strict hygienic rules, social distance, and assessment for infection symptoms among staff and patients/participants. CONCLUSIONS The COVID-19 pandemic interfered with the use of EEG recordings in clinical practice and even more in clinical research. We suggest updated best practices to allow safe EEG recordings in both research and clinical settings. The continued use of EEG is important in those with psychiatric diseases, particularly in times of social alarm such as the COVID-19 pandemic.
Collapse
Affiliation(s)
- Salvatore Campanella
- Laboratoire de Psychologie Médicale et d'Addictologie, ULB Neuroscience Institute (UNI), CHU Brugmann-Université Libre de Bruxelles (U.L.B.), Belgium
| | - Kemal Arikan
- Kemal Arıkan Psychiatry Clinic, Istanbul, Turkey
| | - Claudio Babiloni
- Department of Physiology and Pharmacology "Erspamer", Sapienza University of Rome, Italy.,San Raffaele Cassino, Cassino (FR), Italy
| | - Michela Balconi
- Research Unit in Affective and Social Neuroscience, Department of Psychology, Catholic University of Milan, Milan, Italy
| | - Maurizio Bertollo
- BIND-Behavioral Imaging and Neural Dynamics Center, Department of Neuroscience, Imaging and Clinical Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Viviana Betti
- Department of Psychology, Sapienza University of Rome, Fondazione Santa Lucia, Rome, Italy
| | - Luigi Bianchi
- Dipartimento di Ingegneria Civile e Ingegneria Informatica (DICII), University of Rome Tor Vergata, Rome, Italy
| | - Martin Brunovsky
- National Institute of Mental Health, Klecany Czech Republic.,Third Medical Faculty, Charles University, Prague, Czech Republic
| | - Carla Buttinelli
- Department of Neurosciences, Public Health and Sense Organs (NESMOS), Sapienza University of Rome, Rome, Italy
| | - Silvia Comani
- BIND-Behavioral Imaging and Neural Dynamics Center, Department of Neuroscience, Imaging and Clinical Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Giorgio Di Lorenzo
- Laboratory of Psychophysiology and Cognitive Neuroscience, Chair of Psychiatry, Department of Systems Medicine, School of Medicine and Surgery, University of Rome Tor Vergata, Rome, Italy.,IRCCS Fondazione Santa Lucia, Rome, Italy
| | - Daniel Dumalin
- AZ Sint-Jan Brugge-Oostende AV, Campus Henri Serruys, Lab of Neurophysiology, Department Neurology-Psychiatry, Ostend, Belgium
| | - Carles Escera
- Brainlab-Cognitive Neuroscience Research Group, Department of Clinical Psychology and Psychobiology, Institute of Neurosciences, University of Barcelona, Barcelona, Spain
| | - Andreas Fallgatter
- Department of Psychiatry, University of Tübingen, Germany; LEAD Graduate School and Training Center, Tübingen, Germany.,German Center for Neurodegenerative Diseases DZNE, Tübingen, Germany
| | - Derek Fisher
- Department of Psychology, Mount Saint Vincent University, and Department of Psychiatry, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada
| | | | - Bahar Guntekin
- Department of Biophysics, School of Medicine, Istanbul Medipol University, Istanbul, Turkey
| | - Claudio Imperatori
- Cognitive and Clinical Psychology Laboratory, Department of Human Science, European University of Rome, Rome, Italy
| | - Ryouhei Ishii
- Department of Psychiatry Osaka University Graduate School of Medicine, Osaka, Japan
| | - Hendrik Kajosch
- Laboratoire de Psychologie Médicale et d'Addictologie, ULB Neuroscience Institute (UNI), CHU Brugmann-Université Libre de Bruxelles (U.L.B.), Belgium
| | - Michael Kiang
- Department of Psychiatry, University of Toronto, Toronto, Ontario, Canada
| | - Eduardo López-Caneda
- Psychological Neuroscience Laboratory, Center for Research in Psychology, School of Psychology, University of Minho, Braga, Portugal
| | - Pascal Missonnier
- Mental Health Network Fribourg (RFSM), Sector of Psychiatry and Psychotherapy for Adults, Marsens, Switzerland
| | - Armida Mucci
- Department of Psychiatry, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Sebastian Olbrich
- Psychotherapy and Psychosomatics, Department for Psychiatry, University Hospital Zurich, Zurich, Switzerland
| | | | - Andrea Perrottelli
- Department of Psychiatry, University of Campania "Luigi Vanvitelli", Naples, Italy
| | - Alessandra Pizzuti
- Department of Psychology, Sapienza University of Rome, Fondazione Santa Lucia, Rome, Italy
| | - Diego Pinal
- Psychological Neuroscience Laboratory, Center for Research in Psychology, School of Psychology, University of Minho, Braga, Portugal
| | - Dean Salisbury
- Clinical Neurophysiology Research Laboratory, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA
| | - Yingying Tang
- Shanghai Key Laboratory of Psychotic Disorders, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Paolo Tisei
- Department of Neurosciences, Public Health and Sense Organs (NESMOS), Sapienza University of Rome, Rome, Italy
| | - Jijun Wang
- Shanghai Key Laboratory of Psychotic Disorders, Shanghai Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Istvan Winkler
- Institute of Cognitive Neuroscience and Psychology, Research Centre for Natural Sciences, Budapest, Hungary
| | - Jiajin Yuan
- Institute of Brain and Psychological Sciences, Sichuan Normal University, Chengdu, China
| | - Oliver Pogarell
- Department of Psychiatry and Psychotherapy, University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
36
|
Abstract
Developing reliable and user-friendly electroencephalography (EEG) electrodes remains a challenge for emerging real-world EEG applications. Classic wet electrodes are the gold standard for recording EEG; however, they are difficult to implement and make users uncomfortable, thus severely restricting their widespread application in real-life scenarios. An alternative is dry electrodes, which do not require conductive gels or skin preparation. Despite their quick setup and improved user-friendliness, dry electrodes still have some inherent problems (invasive, relatively poor signal quality, or sensitivity to motion artifacts), which limit their practical utilization. In recent years, semi-dry electrodes, which require only a small amount of electrolyte fluid, have been successfully developed, combining the advantages of both wet and dry electrodes while addressing their respective drawbacks. Semi-dry electrodes can collect reliable EEG signals comparable to wet electrodes. Moreover, their setup is as fast and convenient similar to that of dry electrodes. Hence, semi-dry electrodes have shown tremendous application prospects for real-world EEG acquisition. Herein, we systematically summarize the development, evaluation methods, and practical design considerations of semi-dry electrodes. Some feasible suggestions and new ideas for the development of semi-dry electrodes have been presented. This review provides valuable technical support for the development of semi-dry electrodes toward emerging practical applications.
Collapse
Affiliation(s)
- Guang-Li Li
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou 412007, People's Republic of China
| | | | | | | | | |
Collapse
|
37
|
Moctezuma LA, Molinas M. EEG Channel-Selection Method for Epileptic-Seizure Classification Based on Multi-Objective Optimization. Front Neurosci 2020; 14:593. [PMID: 32625054 PMCID: PMC7312219 DOI: 10.3389/fnins.2020.00593] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Accepted: 05/14/2020] [Indexed: 12/13/2022] Open
Abstract
We present a multi-objective optimization method for electroencephalographic (EEG) channel selection based on the non-dominated sorting genetic algorithm (NSGA) for epileptic-seizure classification. We tested the method on EEG data of 24 patients from the CHB-MIT public dataset. The procedure starts by decomposing the EEG data from each channel into different frequency bands using the empirical mode decomposition (EMD) or the discrete wavelet transform (DWT), and then for each sub-band four features are extracted; two energy values and two fractal dimension values. The obtained feature vectors are then iteratively tested for solving two unconstrained objectives by NSGA-II or NSGA-III; to maximize classification accuracy and to reduce the number of EEG channels required for epileptic seizure classification. Our results have shown accuracies of up to 1.00 with only one EEG channel. Interestingly, when using all the EEG channels available, lower accuracies were achieved compared to the case when EEG channels were selected by NSGA-II or NSGA-III; i.e., in patient 19 we obtained an accuracy of 0.95 using all the channels and 0.975 using only two channels selected by NSGA-III. The results obtained are encouraging and it has been shown that it is possible to classify epileptic seizures using a few electrodes, which provide evidence for the future development of portable EEG seizure detection devices.
Collapse
Affiliation(s)
- Luis Alfredo Moctezuma
- Department of Engineering Cybernetics, Norwegian University of Science and Technology, Trondheim, Norway
| | - Marta Molinas
- Department of Engineering Cybernetics, Norwegian University of Science and Technology, Trondheim, Norway
| |
Collapse
|
38
|
Hinrichs H, Scholz M, Baum AK, Kam JWY, Knight RT, Heinze HJ. Comparison between a wireless dry electrode EEG system with a conventional wired wet electrode EEG system for clinical applications. Sci Rep 2020; 10:5218. [PMID: 32251333 PMCID: PMC7090045 DOI: 10.1038/s41598-020-62154-0] [Citation(s) in RCA: 70] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Accepted: 03/06/2020] [Indexed: 11/09/2022] Open
Abstract
Dry electrode electroencephalogram (EEG) recording combined with wireless data transmission offers an alternative tool to conventional wet electrode EEG systems. However, the question remains whether the signal quality of dry electrode recordings is comparable to wet electrode recordings in the clinical context. We recorded the resting state EEG (rsEEG), the visual evoked potentials (VEP) and the visual P300 (P3) from 16 healthy subjects (age range: 26-79 years) and 16 neurological patients who reported subjective memory impairment (age range: 50-83 years). Each subject took part in two recordings on different days, one with 19 dry electrodes and another with 19 wet electrodes. They reported their preferred EEG system. Comparisons of the rsEEG recordings were conducted qualitatively by independent visual evaluation by two neurologists blinded to the EEG system used and quantitatively by spectral analysis of the rsEEG. The P100 visual evoked potential (VEP) and P3 event-related potential (ERP) were compared in terms of latency, amplitude and pre-stimulus noise. The majority of subjects preferred the dry electrode headset. Both neurologists reported that all rsEEG traces were comparable between the wet and dry electrode headsets. Absolute Alpha and Beta power during rest did not statistically differ between the two EEG systems (p > 0.05 in all cases). However, Theta and Delta power was slightly higher with the dry electrodes (p = 0.0004 for Theta and p < 0.0001 for Delta). For ERPs, the mean latencies and amplitudes of the P100 VEP and P3 ERP showed comparable values (p > 0.10 in all cases) with a similar spatial distribution for both wet and dry electrode systems. These results suggest that the signal quality, ease of set-up and portability of the dry electrode EEG headset used in our study comply with the needs of clinical applications.
Collapse
Affiliation(s)
- Hermann Hinrichs
- Department of Neurology, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany. .,Department of Behavioural Neurology, Leibniz Institute of Neurobiology, Brenneckestr. 6, 39120, Magdeburg, Germany. .,Center for Behavioural Brain Sciences, Otto-von-Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany. .,German Centre for Neurodegenerative Diseases, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany. .,Forschungscampus STIMULATE, Magdeburg, Germany.
| | - Michael Scholz
- Department of Neurology, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Anne Katrin Baum
- Department of Neurology, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Julia W Y Kam
- Helen Wills Neuroscience Institute, University of California - Berkeley, 132 Barker Hall, Berkeley, CA, 94720, USA
| | - Robert T Knight
- Helen Wills Neuroscience Institute, University of California - Berkeley, 132 Barker Hall, Berkeley, CA, 94720, USA.,Department of Psychology, University of California - Berkeley, 130 Barker Hall, Berkeley, CA, 94720, USA
| | - Hans-Jochen Heinze
- Department of Neurology, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany.,Department of Behavioural Neurology, Leibniz Institute of Neurobiology, Brenneckestr. 6, 39120, Magdeburg, Germany.,Center for Behavioural Brain Sciences, Otto-von-Guericke University, Universitätsplatz 2, 39106, Magdeburg, Germany.,German Centre for Neurodegenerative Diseases, Otto-von-Guericke University, Leipziger Str. 44, 39120, Magdeburg, Germany
| |
Collapse
|
39
|
Li G, Wu J, Xia Y, Wu Y, Tian Y, Liu J, Chen D, He Q. Towards emerging EEG applications: a novel printable flexible Ag/AgCl dry electrode array for robust recording of EEG signals at forehead sites. J Neural Eng 2020; 17:026001. [PMID: 32000145 DOI: 10.1088/1741-2552/ab71ea] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVES With the rapid development of EEG-based wearable healthcare devices and brain-computer interfaces, reliable and user-friendly EEG sensors for EEG recording, especially at forehead sites, are highly desirable and challenging. However, existing EEG sensors cannot meet the requirements, since wet electrodes require tedious setup and conductive pastes or gels, and most dry electrodes show unacceptable high contact impedance. In addition, the existing electrodes cannot absorb sweat effectively; sweat would cause cross-interferences, and even short circuits, between adjacent electrodes, especially in the moving scenarios, or a hot and humid environment. To resolve these problems, a novel printable flexible Ag/AgCl dry electrode array was developed for EEG acquisition at forehead sites, mainly consisting of screen printing the Ag/AgCl coating, conductive sweat-absorbable sponges and flexible tines. APPROACH A systematic method was also established to evaluate the flexible dry electrode array. MAIN RESULTS The experimental results show the flexible dry electrode array has reproducible electrode potential, relatively low electrode-skin impedance, and good stability. Moreover, the EEG signals can be effectively captured with a high quality that is comparable to that of wet electrodes. SIGNIFICANCE All the results confirmed the feasibility of forehead EEG recording in real-world scenarios using the proposed flexible dry electrode array, with a rapid and facile operation as well as the advantages of self-application, user-friendliness and wearer comfort.
Collapse
Affiliation(s)
- Guangli Li
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Sciences and Chemistry, Hunan University of Technology, Zhuzhou 412007, People's Republic of China. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | |
Collapse
|
40
|
Pedroni A, Bahreini A, Langer N. Automagic: Standardized preprocessing of big EEG data. Neuroimage 2019; 200:460-473. [DOI: 10.1016/j.neuroimage.2019.06.046] [Citation(s) in RCA: 86] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 05/25/2019] [Accepted: 06/19/2019] [Indexed: 01/08/2023] Open
|
41
|
A Dry Electrode Cap and Its Application in a Steady-State Visual Evoked Potential-Based Brain–Computer Interface. ELECTRONICS 2019. [DOI: 10.3390/electronics8101080] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The wearable electroencephalogram (EEG) dry electrode acquisition system has shown great application prospects in mental state monitoring, the brain–computer interface (BCI), and other fields due to advantages such as being small in volume, light weight, and a ready-to-use facility. This study demonstrates a novel EEG cap with concise structure, easy adjustment size, as well as independently adjustable electrodes. The cap can be rapidly worn and adjusted in both horizontal and vertical dimensions. The dry electrodes on it can be adjusted independently to fit the scalp as quickly as possible. The accuracy of the BCI test employing this device is higher than when employing a headband. The proposed EEG cap makes adjustment easier and the contact impedance of the dry electrodes more uniform.
Collapse
|
42
|
di Fronso S, Fiedler P, Tamburro G, Haueisen J, Bertollo M, Comani S. Dry EEG in Sports Sciences: A Fast and Reliable Tool to Assess Individual Alpha Peak Frequency Changes Induced by Physical Effort. Front Neurosci 2019; 13:982. [PMID: 31619953 PMCID: PMC6763587 DOI: 10.3389/fnins.2019.00982] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Accepted: 09/02/2019] [Indexed: 12/31/2022] Open
Abstract
Novel state-of-the-art amplifier and cap systems enable Electroencephalography (EEG) recording outside of stationary lab systems during physical exercise and body motion. However, extensive preparation time, cleaning, and limited long-term stability of conventional gel-based electrode systems pose significant limitations in out-of-the-lab conditions. Dry electrode systems may contribute to rapid and repetitive mobile EEG acquisition with significantly reduced preparation time, reduced cleaning requirements, and possible self-application by the volunteer but are known for higher channel failure probability and increased sensitivity to movement artifacts. We performed a counterbalanced repeated measure endurance cycling study to objectively validate the performance and applicability of a novel commercially available 64-channel dry electrode cap for sport science. A total of 17 healthy volunteers participated in the study, performing an endurance cycling paradigm comprising five phases: (I) baseline EEG, (II) pre-cycling EEG, (III) endurance cycling, (IV) active recovery, and (V) passive recovery. We compared the performance of the 64-channel dry electrode cap with a commercial gel-based cap system in terms of usability metrics, reliability, and signal characteristics. Furthermore, we validated the performance of the dry cap during a realistic sport science investigation, verifying the hypothesis of a systematic, reproducible shift of the individual alpha peak frequency (iAPF) induced by physical effort. The average preparation time of the dry cap was one-third of the gel-based electrode caps. The average channel reliability of the dry cap varied between 80 ± 15% (Phase I), 66 ± 19% (Phase III), and 91 ± 10% (Phase V). In comparison, the channel reliability of the gel-based cap varied between 95 ± 3, 85 ± 9, and 82 ± 9%, respectively. No considerable differences were evident for the comfort evaluations nor the signal characteristics of both caps. A within-volunteers repeated measure analysis of variance (RM-ANOVA) did not show significant effects of the electrode type on the iAPF [F(1,12) = 1.670, p = 0.221, ηp2 = 0.122, Power = 0.222]. However, a significant increase of the iAPF exists from Phase II to Phases IV and V due to exhaustive physical task. In conclusion, we demonstrated that dry electrode cap is equivalent to the gel-based electrode cap based on signal characteristics, comfort, and signal information content, thereby confirming the usefulness of dry electrodes in sports science and other mobile applications involving ample movement.
Collapse
Affiliation(s)
- Selenia di Fronso
- Behavioral Imaging and Neural Dynamics Center, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.,Department of Medicine and Aging Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Patrique Fiedler
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany.,eemagine Medical Imaging Solutions GmbH, Berlin, Germany
| | - Gabriella Tamburro
- Behavioral Imaging and Neural Dynamics Center, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.,Department of Neurosciences, Imaging and Clinical Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, Ilmenau, Germany.,Department of Neurology, Biomagnetic Center, Jena University Hospital, Jena, Germany
| | - Maurizio Bertollo
- Behavioral Imaging and Neural Dynamics Center, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.,Department of Medicine and Aging Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| | - Silvia Comani
- Behavioral Imaging and Neural Dynamics Center, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy.,Department of Neurosciences, Imaging and Clinical Sciences, University "G. d'Annunzio" of Chieti-Pescara, Chieti, Italy
| |
Collapse
|
43
|
|
44
|
Flexible Multi-Layer Semi-Dry Electrode for Scalp EEG Measurements at Hairy Sites. MICROMACHINES 2019; 10:mi10080518. [PMID: 31382695 PMCID: PMC6722968 DOI: 10.3390/mi10080518] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 07/26/2019] [Accepted: 07/31/2019] [Indexed: 11/21/2022]
Abstract
One of the major challenges of daily wearable electroencephalogram (EEG) monitoring is that there are rarely suitable EEG electrodes for hairy sites. Wet electrodes require conductive gels, which will dry over the acquisition time, making them unstable for long-term EEG monitoring. Additionally, the electrode–scalp impedances of most dry electrodes are not adequate for high quality EEG collection at hairy sites. In view of the above problems, a flexible multi-layer semi-dry electrode was proposed for EEG monitoring in this study. The semi-dry electrode contains a flexible electrode body layer, foam layer and reservoir layer. The probe structure of the electrode body layer enables the electrode to work effectively at hairy sites. During long-term EEG monitoring, electrolytes stored in the reservoir layer are continuously released through the foam layer to the electrode–scalp interface, ensuring a lower electrode–scalp contact impedance. The experimental results showed that the average electrode–scalp impedance of the semi-dry electrode at a hairy site was only 23.89 ± 7.44 KΩ at 10 Hz, and it was lower than 40 KΩ over a long-term use of 5 h. The electrode performed well in both static and dynamic EEG monitoring, where the temporal correlation with wet electrode signals at the hairy site could reach 94.25% and 90.65%, respectively, and specific evoked EEG signals could be collected. The flexible multi-layer semi-dry electrode can be well applied to scalp EEG monitoring at hairy sites, providing a promising solution for daily long-term monitoring of wearable EEGs.
Collapse
|
45
|
Tamburro G, Stone DB, Comani S. Automatic Removal of Cardiac Interference (ARCI): A New Approach for EEG Data. Front Neurosci 2019; 13:441. [PMID: 31133785 PMCID: PMC6517508 DOI: 10.3389/fnins.2019.00441] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Accepted: 04/17/2019] [Indexed: 11/18/2022] Open
Abstract
EEG recordings are generally affected by interference from physiological and non-physiological sources which may obscure underlying brain activity and hinder effective EEG analysis. In particular, cardiac interference can be caused by the electrical activity of the heart and/or cardiovascular activity related to blood flow. Successful EEG application in sports science settings requires a method for artifact removal that is automatic and flexible enough to be applied in a variety of acquisition conditions without requiring simultaneous ECG recordings that could restrict movement. We developed an automatic method for classifying and removing both electrical cardiac and cardiovascular artifacts (ARCI) that does not require additional ECG recording. Our method employs independent component analysis (ICA) to isolate data independent components (ICs) and identifies the artifactual ICs by evaluating specific IC features in the time and frequency domains. We applied ARCI to EEG datasets with cued artifacts and acquired during an eyes-closed condition. Data were recorded using a standard EEG wet cap with either 128 or 64 electrodes and using a novel dry electrode cap with either 97 or 64 dry electrodes. All data were decomposed into different numbers of components to evaluate the effect of ICA decomposition level on effective cardiac artifact detection. ARCI performance was evaluated by comparing automatic ICs classifications with classifications performed by experienced investigators. Automatic and investigator classifications were highly consistent resulting in an overall accuracy greater than 99% in all datasets and decomposition levels, and an average sensitivity greater than 90%. Best results were attained when data were decomposed into a fewer number of components where the method achieved perfect sensitivity (100%). Performance was also evaluated by comparing automatic component classification with externally recorded ECG. Results showed that ICs automatically classified as artifactual were significantly correlated with ECG activity whereas the other ICs were not. We also assessed that the interference affecting EEG signals was reduced by more than 82% after automatic artifact removal. Overall, ARCI represents a significant step in the detection and removal of cardiac-related EEG artifacts and can be applied in a variety of acquisition settings making it ideal for sports science applications.
Collapse
Affiliation(s)
- Gabriella Tamburro
- BIND – Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti-Pescara, Chieti, Italy
- Department of Neuroscience, Imaging and Clinical Sciences, University “G. d’Annunzio” of Chieti-Pescara, Chieti, Italy
| | - David B. Stone
- BIND – Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti-Pescara, Chieti, Italy
- Department of Neuroscience, Imaging and Clinical Sciences, University “G. d’Annunzio” of Chieti-Pescara, Chieti, Italy
| | - Silvia Comani
- BIND – Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti-Pescara, Chieti, Italy
- Department of Neuroscience, Imaging and Clinical Sciences, University “G. d’Annunzio” of Chieti-Pescara, Chieti, Italy
| |
Collapse
|
46
|
Fiedler P, Muhle R, Griebel S, Pedrosa P, Fonseca C, Vaz F, Zanow F, Haueisen J. Contact Pressure and Flexibility of Multipin Dry EEG Electrodes. IEEE Trans Neural Syst Rehabil Eng 2019; 26:750-757. [PMID: 29641379 DOI: 10.1109/tnsre.2018.2811752] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In state-of-the-art electroencephalography (EEG) Silver/Silver-Chloride electrodes are applied together with electrolyte gels or pastes. Their application requires extensive preparation, trained medical staff and limits measurement time and mobility. We recently proposed a novel multichannel cap system for dry EEG electrodes for mobile and out-of-the-lab EEG acquisition. During the tests with these novel polymer-based multipin dry electrodes, we observed that the quality of the recording depends on the applied normal force and resulting contact pressure. Consequently, in this paper we systematically investigate the influence of electrode-skin contact pressure and electrode substrate flexibility on interfacial impedance and perceived wearing comfort in a study on 12 volunteers. The normal force applied to the electrode was varied between the minimum required force to achieve impedances and a maximum of 4 N, using a new force measurement applicator. We found that for a polymer shore hardness A98, with increasing normal force, the impedance decreases from and to and at frontal hairless and temporal hairy positions, respectively. Similar results were obtained for shore A90, A80, and A70. The best compromise of low and stable impedances as well as a good wearing comfort was determined for applied normal forces between 2 and 3 N using electrodes with shore A98 or A90. Our results provide the basis for improved EEG cap designs with optimal wearing comfort and recording quality for dry multipin electrodes, which will enable new fields of application for EEG.
Collapse
|
47
|
Kappel SL, Rank ML, Toft HO, Andersen M, Kidmose P. Dry-Contact Electrode Ear-EEG. IEEE Trans Biomed Eng 2019; 66:150-158. [DOI: 10.1109/tbme.2018.2835778] [Citation(s) in RCA: 66] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
48
|
Bradford JC, Burke B, Nguyen C, Slipher GA, Mrozek R, Hairston D. Performance of conformable, dry EEG sensors. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:4957-4960. [PMID: 30441455 DOI: 10.1109/embc.2018.8513428] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
We have recently developed a conformable solid state material solution (carbon nanofiber filled polydimethylsilisoxane, CNF-PDMS) for electroencephalography (EEG) electrodes. In this study, we tested the efficacy of electrodes molded from this material to record well studied neural phenomena using a battery of standard laboratory tasks. Event related potential (ERP) and eyes open/closed results show performance matching that of commercially available metal-pin based dry EEG electrode, while summary statistics (correlation and RMSE) show matched and even improved ability to track local and global fluctuations in EEG. We present baseline data that demonstrates CNFPDMS is a viable solution for conformable, safe, dry EEG electrodes.
Collapse
|
49
|
Influence of Stainless Needle Electrodes and Silver Disk Electrodes over the Interhemispheric Cerebral Coherence Value in Vigil Dogs. SENSORS 2018; 18:s18113990. [PMID: 30453513 PMCID: PMC6264086 DOI: 10.3390/s18113990] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 11/12/2018] [Accepted: 11/13/2018] [Indexed: 12/14/2022]
Abstract
Electroencephalography (EEG) is an objective diagnostic tool in the evaluation of cerebral functionality, both in human and veterinary medicine. For EEG acquisition, different types of electrodes are used, as long as they have no impact on the recorded background activity. However, to date, the influence of electrode type on quantitative EEG and cerebral coherence has not been investigated. Twenty EEG traces (ten with needle electrodes and ten with disk electrodes) were recorded from ten mesocephalic vigil dogs in a monopolar montage. Values for interhemispheric coherence for each frequency band were compared between stainless needle and silver disk electrodes traces. Our results show that the values of interhemispheric coherence in vigil dogs are depending of the type of electrodes used in EEG recordings. In the frontal (FP) channel, for delta and theta frequency bands, the registered coherence is significantly higher when stainless needle electrodes are used. Our results might have important consequences in the field of canine neurology and applied neuroscience, as the frontal channel analysis is preferred in aging and behavior studies.
Collapse
|
50
|
Tivadar RI, Murray MM. A Primer on Electroencephalography and Event-Related Potentials for Organizational Neuroscience. ORGANIZATIONAL RESEARCH METHODS 2018. [DOI: 10.1177/1094428118804657] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Electroencephalography (EEG) was the first of the noninvasive brain measures in neuroscience. Technical advances over the last 100 years or so have rendered EEG a true brain imaging technique. Here, we provide an accessible primer on the biophysics of EEG, on measurement aspects, and on the analysis of EEG data. We use the example of event-related potentials (ERPs), although the issues apply equally to other varieties of EEG signals, and provide an overview of analytic methods at the base of the so-called electrical neuroimaging framework. We detail the interpretational strengths of electrical neuroimaging for organizational researchers and describe some domains of ongoing technical developments. We likewise emphasize practical considerations with the use of EEG in more real-world settings. This primer is intended to provide organizational researchers specifically, and novices more generally, an access point to understanding how EEG may be applied in their research.
Collapse
Affiliation(s)
- Ruxandra I. Tivadar
- LINE (Laboratory for Investigative Neurophysiology), Department of Radiology, University Hospital Center and University of Lausanne, Lausanne, Switzerland
- Department of Ophthalmology, University of Lausanne and Fondation Asile des Aveugles, Lausanne, Switzerland
| | - Micah M. Murray
- LINE (Laboratory for Investigative Neurophysiology), Department of Radiology, University Hospital Center and University of Lausanne, Lausanne, Switzerland
- Department of Ophthalmology, University of Lausanne and Fondation Asile des Aveugles, Lausanne, Switzerland
- EEG Brain Mapping Core, Center for Biomedical Imaging (CIBM), University Hospital Center and University of Lausanne, Lausanne, Switzerland
- Department of Hearing and Speech Sciences, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|