1
|
Capella-Monsonís H, Crum RJ, Hussey GS, Badylak SF. Advances, challenges, and future directions in the clinical translation of ECM biomaterials for regenerative medicine applications. Adv Drug Deliv Rev 2024; 211:115347. [PMID: 38844005 DOI: 10.1016/j.addr.2024.115347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 05/29/2024] [Accepted: 06/03/2024] [Indexed: 06/11/2024]
Abstract
Extracellular Matrix (ECM) scaffolds and biomaterials have been widely used for decades across a variety of diverse clinical applications and have been implanted in millions of patients worldwide. ECM-based biomaterials have been especially successful in soft tissue repair applications but their utility in other clinical applications such as for regeneration of bone or neural tissue is less well understood. The beneficial healing outcome with the use of ECM biomaterials is the result of their biocompatibility, their biophysical properties and their ability to modify cell behavior after injury. As a consequence of successful clinical outcomes, there has been motivation for the development of next-generation formulations of ECM materials ranging from hydrogels, bioinks, powders, to whole organ or tissue scaffolds. The continued development of novel ECM formulations as well as active research interest in these materials ensures a wealth of possibilities for future clinical translation and innovation in regenerative medicine. The clinical translation of next generation formulations ECM scaffolds faces predictable challenges such as manufacturing, manageable regulatory pathways, surgical implantation, and the cost required to address these challenges. The current status of ECM-based biomaterials, including clinical translation, novel formulations and therapies currently under development, and the challenges that limit clinical translation of ECM biomaterials are reviewed herein.
Collapse
Affiliation(s)
- Héctor Capella-Monsonís
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, 450 Technology Drive, Pittsburgh, PA 15219, USA; Department of Surgery, School of Medicine, University of Pittsburgh, 200 Lothrop Street, Pittsburgh, PA 15213, USA; Viscus Biologics LLC, 2603 Miles Road, Cleveland, OH 44128, USA
| | - Raphael J Crum
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, 450 Technology Drive, Pittsburgh, PA 15219, USA; Department of Surgery, School of Medicine, University of Pittsburgh, 200 Lothrop Street, Pittsburgh, PA 15213, USA
| | - George S Hussey
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, 450 Technology Drive, Pittsburgh, PA 15219, USA; Department of Pathology, School of Medicine, University of Pittsburgh, 200 Lothrop Street, Pittsburgh, PA 15213, USA
| | - Stephen F Badylak
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, 450 Technology Drive, Pittsburgh, PA 15219, USA; Department of Surgery, School of Medicine, University of Pittsburgh, 200 Lothrop Street, Pittsburgh, PA 15213, USA; Department of Bioengineering, University of Pittsburgh, 3700 O'Hara Street, Pittsburgh, PA 15261, USA.
| |
Collapse
|
2
|
Gökler DJ, Karácsony AF, Faragó D, Szebényi G, Kiss RM, Pap K. The effect of sterilization and storage on the viscoelastic properties of human tendon allografts - Continued: Storage for 0 to 4 months. J Biomech 2024; 162:111904. [PMID: 38134466 DOI: 10.1016/j.jbiomech.2023.111904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 12/09/2023] [Accepted: 12/13/2023] [Indexed: 12/24/2023]
Abstract
The role of donor-derived tendons, also known as allografts, in anterior cruciate ligament replacement surgeries is steadily increasing. Before surgery, temporary storage and, in most cases, sterilization are essential. It is, thus, crucial to determine how these procedures alter the grafts' biomechanical properties. The purpose of this research was to analyze the effect of different sterilization methods (native, frozen, frozen + 21 kGy gamma irradiation, frozen + 21 kGy electron beam irradiation) and storage durations (0 to 4 months) on the deformation and creep of two tendon types (tibialis anterior, peroneus longus). 80 tibialis anterior and 83 peroneus longus tendons from 51 human cadavers were included. The samples were removed, placed in a radio-cryoprotectant solution, then slowly cooled, sterilized and stored at -80 °C. All groups were subject to 60 s static creep test with 250 N load. Deformation during the loading phase, creep during static loading, and the ratio of these two were evaluated. Deformation at the end of the loading phase and creep consistently exhibited significantly smaller values in the tibialis anterior compared to the peroneus longus type, as well as in electron beam-sterilized grafts as opposed to gamma beam-sterilized ones. Prolonged storage periods (within 0 to 4 months) resulted in a notable increase in these values, particularly in deformation. Based on the experimental data, the tibialis anterior tendon type and sterilization by gamma beam irradiation are better choices for anterior cruciate ligament reconstruction than the peroneus longus and sterilization by electron beam. Increased storage time affects negatively the evaluated mechanical properties.
Collapse
Affiliation(s)
- Daniella Judit Gökler
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary
| | - Atilla Ferenc Karácsony
- Semmelweis University Budapest, Department of Traumatology, Hungary; Buda Hospital of the Hospitaller Order of Saint John of God, Department of Orthopedics, Hungary
| | - Dénes Faragó
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary
| | - Gábor Szebényi
- MTA-BME Lendület Lightweight Polymer Composites Research Group, Hungary; Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Polymer Engineering, Hungary.
| | - Rita Mária Kiss
- Budapest University of Technology and Economics, Faculty of Mechanical Engineering, Department of Mechatronics, Optics, and Mechanical Engineering Informatics, Hungary
| | - Károly Pap
- Semmelweis University Budapest, Department of Traumatology, Hungary; Uzsoki Hospital, Department of Orthopedics and Traumatology, Hungary
| |
Collapse
|
3
|
Chandler KM, Schick S, Hargreaves M, Elphingstone J, Brabston E, Evely T, Casp A, Momaya AM. Impact of irradiation on load-to-failure in bone-patellar tendon-bone allografts: A systematic review and meta-analysis. J Orthop 2023; 46:18-23. [PMID: 37942219 PMCID: PMC10630551 DOI: 10.1016/j.jor.2023.10.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 10/21/2023] [Indexed: 11/10/2023] Open
Abstract
Introduction To evaluate the impact various levels of irradiation have on bone-patellar tendon-bone (BTB) allograft load-to-failure. Materials and methods Pubmed, Google Scholar and Embase were searched for studies reporting load-to-failure measurements of BTB allografts following gamma or eBeam irradiation. All systematic reviews, editorials, as well as studies that utilized animal models and/or other graft sources (achilles, hamstring, quadriceps) were excluded. Meta-analysis was performed to compare the impact of low dose (19 ≤ kGy), intermediate (20-49 kGy) and high dose (>50 kGy) gamma and eBeam radiation on load-to-failure. Results Twelve studies, containing a total of 429 BTB allografts (159 controls, 270 irradiated), were identified. Load-to-failure of BTB allograft was significantly decreased at intermediate (20-49 kGy) doses of radiation, while low (≤19 kGy) and high (>50 kGy) doses did not significantly change load-to-failure. Conclusions Intermediate doses of radiation may negatively impact the biomechanical integrity of BTB allograft in vitro. Future studies are required to examine clinical outcomes at varying irradiation levels.
Collapse
Affiliation(s)
- Kelly M. Chandler
- University of Alabama at Birmingham Department of Orthopaedic Surgery, Birmingham, AL, USA
| | - Sam Schick
- University of Alabama at Birmingham Department of Orthopaedic Surgery, Birmingham, AL, USA
| | - Mathew Hargreaves
- University of Alabama at Birmingham Department of Orthopaedic Surgery, Birmingham, AL, USA
| | - Joseph Elphingstone
- University of Alabama at Birmingham Department of Orthopaedic Surgery, Birmingham, AL, USA
| | - Eugene Brabston
- University of Alabama at Birmingham Department of Orthopaedic Surgery, Birmingham, AL, USA
| | - Thomas Evely
- University of Alabama at Birmingham Department of Orthopaedic Surgery, Birmingham, AL, USA
| | - Aaron Casp
- University of Alabama at Birmingham Department of Orthopaedic Surgery, Birmingham, AL, USA
| | - Amit M. Momaya
- University of Alabama at Birmingham Department of Orthopaedic Surgery, Birmingham, AL, USA
| |
Collapse
|
4
|
Runer A, Keeling L, Wagala N, Nugraha H, Özbek EA, Hughes JD, Musahl V. Current trends in graft choice for anterior cruciate ligament reconstruction - part I: anatomy, biomechanics, graft incorporation and fixation. J Exp Orthop 2023; 10:37. [PMID: 37005974 PMCID: PMC10067784 DOI: 10.1186/s40634-023-00600-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 03/22/2023] [Indexed: 04/04/2023] Open
Abstract
Graft selection in anterior cruciate ligament (ACL) reconstruction is critical, as it remains one of the most easily adjustable factors affecting graft rupture and reoperation rates. Commonly used autografts, including hamstring tendon, quadriceps tendon and bone-patellar-tendon-bone, are reported to be biomechanically equivalent or superior compared to the native ACL. Despite this, such grafts are unable to perfectly replicate the complex anatomical and histological characteristics of the native ACL. While there remains inconclusive evidence as to the superiority of one autograft in terms of graft incorporation and maturity, allografts appear to demonstrate slower incorporation and maturity compared to autografts. Graft fixation also affects graft properties and subsequent outcomes, with each technique having unique advantages and disadvantages that should be carefully considered during graft selection.
Collapse
Affiliation(s)
- Armin Runer
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA.
- Department for Sports Orthopaedics, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
| | - Laura Keeling
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA
| | - Nyaluma Wagala
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA
| | - Hans Nugraha
- Department of Orthopaedic and Traumatology, Faculty of Medicine, University of Udayana, / Prof. Dr. I.G.N.G. Ngoerah General Hospital, Denpasar, Bali, Indonesia
| | - Emre Anil Özbek
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Orthopedics and Traumatology, Ankara University, Ankara, Turkey
| | - Jonathan D Hughes
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Volker Musahl
- Department of Orthopaedic Surgery, UPMC Freddie Fu Sports Medicine Center, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
5
|
Farago D, Kozma B, Kiss RM. Categorize the existing clamps used for tensile test of human graft- a systematic review. BMC Musculoskelet Disord 2022; 23:707. [PMID: 35879684 PMCID: PMC9316330 DOI: 10.1186/s12891-022-05650-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 07/13/2022] [Indexed: 11/13/2022] Open
Abstract
Background The use of tendon allografts for orthopedic repair has gained wide acceptance in recent years, most notably in anterior cruciate tendon reconstruction. Multiple studies support the use of tendon allografts and the benefits of its use are well accepted and understood. One of the important criteria of the use of tendon allografts is statistically similar histological and biomechanical properties to autographs. The aim of this systematic literature review is to investigate and categorize existing clamps used in the determination of the biomechanical properties of tendons such as maximum load, maximum strength, modulus of elasticity, ultimate strain, and stiffness. A variety of clamps for use during the endurance test of tendons were categorized according to the temperature used during the measurement. The clamps are divided into three groups: room temperature, cooled and heated clamps. The second goal of our review is to overview of clamps on the following aspects: name of clamp, author and date, type of clamps, type of endurance test (static or dynamic), type preloading (dynamic or static), type of tendon and measured and calculated parameters, and summarize in Table 3, as a comprehensive catalogue. Methods This systematic review was carried out in keeping with the PRISMA 2020 E&E and the PRISMA-S guidelines and checklists. A search was conducted for publications dating between 1991 and February 28th 2022 through three electronic databases (Web of Science, Scopus, and PubMed). We used Critical Appraisal Skills Program checklist to check the quality of included articles. Results The database search and additional sources resulted in 1725 records. 1635 records eliminated during the screening for various reasons (case report, other languages, book chapter, unavailable text/conference abstract, unrelated topic). The number of articles used in the final synthesis was 90. A variety of clamps for use during the endurance test of tendons were identified and categorized according to the temperature used during the measurement. Based on this, the clamps are divided into three groups: room temperature, cooled or heated clamps. Conclusions On the basis of the systematic literature review, mechanical parameters determined by usage with cooled clamps proved to be more reliable than with those at room temperature and with heated clamps. The collected information from the articles included name of clamp, author and date, type of clamps, type of endurance test (static or dynamic), type preloading (dynamic or static), type of tendon and measured and calculated parameters given in Table 3. summarized. The main advantage of the cooled clamps is that there is no limit to the type and length of the tendon. This study provides an overview of clamps and does not represent the modernity of any method. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-022-05650-w.
Collapse
Affiliation(s)
- Denes Farago
- Cooperation Research Center for Biomechanics, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary. .,Department of Mechatronics, Optics and Mechanical Engineering Informatics, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary.
| | - Blanka Kozma
- Department of Biomedical Engineering, SUNY University at Buffalo, Buffalo, USA
| | - Rita Maria Kiss
- Department of Mechatronics, Optics and Mechanical Engineering Informatics, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, Budapest, Hungary
| |
Collapse
|
6
|
Sant NJ, Proffen BL, Murray MM. Effects of radiation dose and nitrogen purge on collagen scaffold properties. J Biomater Appl 2021; 36:1011-1018. [PMID: 34607497 DOI: 10.1177/08853282211047683] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Sterilization of medical devices is commonly performed using radiation methods. However, collagen materials can be damaged when using standard radiation doses (25 kGy). Small increases of radiation dose can allow for increases in the acceptable initial bioburden load of aseptically manufactured devices while maintaining required sterility assurance levels, which is often critical in early stage translational settings. In this study, we hypothesized that small increases in radiation dose from 15 to 20 kGy would result in significant changes to several key characteristics of collagen scaffolds. Scaffolds were manufactured by lyophilizing the pepsin digest of dense bovine connective tissue in cylindrical molds and were irradiated at either 0, 15, 17.5, or 20 kGy with an additional group packaged in nitrogen and irradiated at 17.5 kGy. Groups were evaluated for changes to the soluble collagen and glycosaminoglycan mass fractions, protein banding patterns in electrophoresis, a collagen fragmentation assay, and resistance to enzymatic degradation. All parameters were statistically analyzed using one-way analysis of variance with Tukey's correction for multiple comparisons. The soluble collagen mass fraction was significantly decreased in the 20 kGy group; however, there was no significant effect of radiation dose or a nitrogen-rich environment on the other measured parameters, including protein banding patterns, fragmented collagen content, and resistance to enzymatic degradation.Statement of Clinical Significance: Collagen scaffolds have proven useful in clinical applications but can be damaged by standard radiation doses. Low-dose sterilization may be a viable alternative that minimally impacts key properties of these scaffolds.
Collapse
Affiliation(s)
- Nicholas J Sant
- Department of Orthopaedic Surgery, 1862Boston Children's Hospital, Boston, MA, USA
| | - Benedikt L Proffen
- Department of Orthopaedic Surgery, 1862Boston Children's Hospital, Boston, MA, USA
| | - Martha M Murray
- Department of Orthopaedic Surgery, 1862Boston Children's Hospital, Boston, MA, USA
| |
Collapse
|
7
|
Łabuś W, Kitala D, Klama-Baryła A, Szapski M, Kraut M, Smętek W, Glik J, Kucharzewski M, Rojczyk E, Utrata-Wesołek A, Trzebicka B, Szeluga U, Sobota M, Poloczek R, Kamiński A. Influence of electron beam irradiation on extracellular matrix of the human allogeneic skin grafts. J Biomed Mater Res B Appl Biomater 2021; 110:547-563. [PMID: 34478207 DOI: 10.1002/jbm.b.34934] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 06/29/2021] [Accepted: 08/22/2021] [Indexed: 12/14/2022]
Abstract
The nonviable allogeneic human skin grafts might be considered as the most suitable skin substitutes in the treatment of extensive and deep burns. However, in accordance to biological security such grafts require the final sterilization prior to clinical application. The aim of the study was to verify the influence of electron beam irradiation of three selected doses: 18, 25, and 35 kGy on the extracellular matrix of human skin. Prior to sterilization, the microbiological tests were conducted and revealed contamination in all examined cases. Individual groups were subjected to single electron beam radiation sterilization at proposed doses and then subjected to microbiological tests again. The results of microbiological testing performed for all irradiation doses used were negative. Only in the control group was a growth of microorganisms observed. The FTIR spectrometry tests were conducted followed by the histological evaluation and mechanical tests. In addition, cost analysis of radiation sterilization of individual doses was performed. The results of spectroscopic analysis, mechanical tests, and histological staining showed no significant changes in composition and characteristics of tested tissues after their irradiation, in comparison to control samples. The cost analysis has shown that irradiation with 18 kGy is the most cost-effective and 35 kGy is the least favorable. However, according to biological risk reduction, the recommended sterilization dose is 35 kGy, despite the higher price compared to the other doses tested.
Collapse
Affiliation(s)
- Wojciech Łabuś
- Dr Stanisław Sakiel Center for Burns Treatment, Siemianowice Śląskie, Poland
| | - Diana Kitala
- Dr Stanisław Sakiel Center for Burns Treatment, Siemianowice Śląskie, Poland
| | | | - Michał Szapski
- Dr Stanisław Sakiel Center for Burns Treatment, Siemianowice Śląskie, Poland.,Gyncentrum, Laboratory of Molecular Biology and Virology, Katowice, Poland
| | - Małgorzata Kraut
- Dr Stanisław Sakiel Center for Burns Treatment, Siemianowice Śląskie, Poland
| | - Wojciech Smętek
- Dr Stanisław Sakiel Center for Burns Treatment, Siemianowice Śląskie, Poland.,Warsaw University of Technology, Warsaw, Poland
| | - Justyna Glik
- Dr Stanisław Sakiel Center for Burns Treatment, Siemianowice Śląskie, Poland.,Department of Chronic Wounds Healing Management Chronic Wound Care, School of Health Sciences in Katowice, Medical University of Silesia, Katowice, Poland
| | - Marek Kucharzewski
- Dr Stanisław Sakiel Center for Burns Treatment, Siemianowice Śląskie, Poland.,Department of Descriptive and Topographic Anatomy, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia, Zabrze, Poland
| | - Ewa Rojczyk
- Department of Descriptive and Topographic Anatomy, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia, Zabrze, Poland
| | | | - Barbara Trzebicka
- Centre of Polymer and Carbon Materials, Polish Academy of Sciences, Zabrze, Poland
| | - Urszula Szeluga
- Centre of Polymer and Carbon Materials, Polish Academy of Sciences, Zabrze, Poland
| | - Michał Sobota
- Centre of Polymer and Carbon Materials, Polish Academy of Sciences, Zabrze, Poland
| | - Ryszard Poloczek
- Laboratory for Microscopic Examination "Diagno-Med", Siemianowice Slaskie, Poland
| | - Artur Kamiński
- Department of Transplantology and Central Tissue Bank, Medical University of Warsaw, Warszawa, Poland.,National Centre for Tissue and Cell Banking, Warszawa, Poland
| |
Collapse
|
8
|
Different sterilization and disinfection methods used for human tendons - a systematic review using mechanical properties to evaluate tendon allografts. BMC Musculoskelet Disord 2021; 22:404. [PMID: 33941147 PMCID: PMC8091719 DOI: 10.1186/s12891-021-04296-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Accepted: 04/23/2021] [Indexed: 11/25/2022] Open
Abstract
Background It is important to know the biomechanical properties of an allograft. This is because when looking to do a transplant of a tendon, the tendon must have very similar biomechanical properties to the original tendon. To use tendon allografts, it is critical to properly sterilize the tendon before implantation. In past decades, several sterilization procedures have been used. This study aimed to systematically evaluate the existing literature to compare the values of failure load/ultimate strength and Young’s modulus of elasticity of different sterilization methods on commonly used tendon allografts. Five major scientific literature databases (Web of Science, Science Direct, Scopus, PLOS ONE, Hindawi) and additional sources were used. Results Studies used had to show a particular sterilization method. Studies were identified to meet the following inclusion criteria: is a controlled laboratory study, gamma irradiation (dose reported), and other sterilization methods. Search for publications dated between 1991 and March 31st, 2020. The database search and additional sources resulted in 284 records. Two hundred thirty records eliminated during the screening for various reasons. The number of articles used in the final synthesis was 54. Conclusions Identified sterilization methods (gamma irradiation, ethylene oxid, supercritical carbon dioxide (SCCO2), BioCleanse, Electron Beam) are offered as a catalog of potential methods. As a result of the broadness of the present research, it provides an overview of sterilization methods and their effect on the mechanical properties (failure load and Young’s modulus of elasticity) of tendons. It does not stand for the state-of-the-art of any single process. Based on a systematic literature review, we recommend freezing and gamma irradiation or electron beam at 14.8–28.5 kGy. These methods are effective at keeping or improving the mechanical properties, while fully sterilizing the inside and the outside of the tendon. Other sterilization method (ethylene oxide, supercritical carbon dioxide (SCCO2), BioCleanse) deteriorated the mechanical properties. These methods are not recommended. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-021-04296-4.
Collapse
|
9
|
Capella-Monsonís H, Zeugolis DI. Decellularized xenografts in regenerative medicine: From processing to clinical application. Xenotransplantation 2021; 28:e12683. [PMID: 33709410 DOI: 10.1111/xen.12683] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 01/28/2021] [Accepted: 02/25/2021] [Indexed: 12/13/2022]
Abstract
Decellularized xenografts are an inherent component of regenerative medicine. Their preserved structure, mechanical integrity and biofunctional composition have well established them in reparative medicine for a diverse range of clinical indications. Nonetheless, their performance is highly influenced by their source (ie species, age, tissue) and processing (ie decellularization, crosslinking, sterilization and preservation), which govern their final characteristics and determine their success or failure for a specific clinical target. In this review, we provide an overview of the different sources and processing methods used in decellularized xenografts fabrication and discuss their effect on the clinical performance of commercially available decellularized xenografts.
Collapse
Affiliation(s)
- Héctor Capella-Monsonís
- 1Regenerative, Modular & Developmental Engineering Laboratory (REMODEL), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland.,Science Foundation Ireland (SFI) Centre for Research in Medical Devices (CÚRAM), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland
| | - Dimitrios I Zeugolis
- 1Regenerative, Modular & Developmental Engineering Laboratory (REMODEL), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland.,Science Foundation Ireland (SFI) Centre for Research in Medical Devices (CÚRAM), Biomedical Sciences Building, National University of Ireland Galway (NUI Galway), Galway, Ireland.,Regenerative, Modular & Developmental Engineering Laboratory (REMODEL), Faculty of Biomedical Sciences, Università della Svizzera Italiana (USI), Lugano, Switzerland
| |
Collapse
|
10
|
Naveen NB, Deckard ER, Buller LT, Meneghini RM. Enhanced Biomechanical Performance of a Modern Polyester Surgical Mesh for Extensor Mechanism Reconstruction in Total Knee Arthroplasty. J Arthroplasty 2020; 35:3311-3317. [PMID: 32591232 DOI: 10.1016/j.arth.2020.05.072] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 05/26/2020] [Accepted: 05/28/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Extensor mechanism (EM) disruption following total knee arthroplasty is a devastating postoperative complication. Reconstruction with a synthetic mesh is one treatment option, although the optimal mesh material remains unknown. This study sought to compare the mechanical properties of 2 mesh material types that can be used for EM reconstruction. METHODS Mechanical properties of a polypropylene mesh (Marlex mesh) and Ligament Advanced Reinforcement System (LARS) mesh were compared using force-displacement data from a material testing machine simulating knee movement during normal human gait. Tension to failure/ultimate tensile load, stiffness coefficients, axial strain, and cyclic hysteresis testing were measured and calculated. RESULTS Compared to polypropylene mesh, LARS mesh demonstrated a significantly higher mean ultimate tensile load (2223 N vs 1245 N, P = .002) and stiffness coefficient (255 N/mm vs 14 N/mm, P = .035) in tension to failure testing, and significantly more energy dissipation (hysteresis) in hysteresis testing (771 kJ vs 23 kJ; P ≤ .040). LARS mesh also demonstrated significantly less maximum displacement compared to the polypropylene mesh (9.2 mm vs 90.4 mm; P ≤ .001). CONCLUSION Compared to polypropylene mesh, LARS mesh showed superior performance related to force-displacement testing. The enhanced mechanical performance of LARS mesh may correlate clinically to fewer failures, increased longevity, and higher resistance to plastic deformation (extensor lag). Future research should evaluate survivorship and clinical outcomes of these meshes when used for EM reconstruction.
Collapse
Affiliation(s)
- Neal B Naveen
- Indiana University School of Medicine, Indianapolis, IN
| | - Evan R Deckard
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, IN
| | - Leonard T Buller
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, IN; IU Health Hip & Knee Center, Indiana University Health Physicians, Fishers, IN
| | - R Michael Meneghini
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, IN; IU Health Hip & Knee Center, Indiana University Health Physicians, Fishers, IN
| |
Collapse
|
11
|
|
12
|
Design and Characterization of Injectable Poly(Lactic-Co-Glycolic Acid) Pastes for Sustained and Local Drug Release. Pharm Res 2020; 37:36. [PMID: 31965346 DOI: 10.1007/s11095-019-2730-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 10/31/2019] [Indexed: 01/09/2023]
Abstract
PURPOSE We describe the preparation of injectable polymeric paste (IPP) formulations for local and sustained release of drugs. Furthermore, we include the characterization and possible applications of such pastes. Particular attention is paid to characteristics relevant to the successful clinical formulation development, such as viscosity, injectability, degradation, drug release, sterilization, stability performance and pharmacokinetics. METHODS Paste injectability was characterized using measured viscosity and the Hagen-Poiseuille equation to determine injection forces. Drug degradation, release and formulation stability experiments were performed in vitro and drug levels were quantified using HPLC-UV methods. Pharmacokinetic evaluation of sustained-release lidocaine IPPs used five groups of six rats receiving increasing doses subcutaneously. An anti-cancer formulation was evaluated in a subcutaneous tumor xenograft mouse model. RESULTS The viscosity and injectability of IPPs could be controlled by changing the polymeric composition. IPPs demonstrated good long-term stability and tunable drug-release with low systemic exposure in vivo in rats. Preliminary data in a subcutaneous tumor model points to a sustained anticancer effect. CONCLUSIONS These IPPs are tunable platforms for local and sustained delivery of drugs and have potential for further clinical development to treat a number of diseases.
Collapse
|
13
|
Beer AJ, Tauro TM, Redondo ML, Christian DR, Cole BJ, Frank RM. Use of Allografts in Orthopaedic Surgery: Safety, Procurement, Storage, and Outcomes. Orthop J Sports Med 2019; 7:2325967119891435. [PMID: 31909057 PMCID: PMC6937533 DOI: 10.1177/2325967119891435] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
The use of allografts has become a vital option for orthopaedic surgeons in the treatment of a variety of musculoskeletal lesions, ranging from osteochondral defects in the glenohumeral joint to meniscal deficiency in the young athlete. Nevertheless, barriers to treating a patient with an allograft-based procedure may arise from concerns over disease transmission, the navigation of tissue banks that supply allografts, the process of obtaining insurance approval, or optimal storage methods. This review serves to support orthopaedic surgeons in the incorporation of allografts into their practice by quelling these potential concerns. Fresh osteochondral allografts, fresh-frozen meniscal allografts, soft tissue allografts, and off-the-shelf cartilage products are the focus of this review amid broad overviews of allograft safety and tissue bank practices in the United States.
Collapse
Affiliation(s)
- Adam J Beer
- Department of Orthopedics, Rush University Medical Center, Chicago, Illinois, USA
| | - Tracy M Tauro
- Department of Orthopedics, Rush University Medical Center, Chicago, Illinois, USA
| | - Michael L Redondo
- Department of Orthopaedics, University of Illinois at Chicago, Chicago, Illinois, USA
| | - David R Christian
- Department of Orthopaedic Surgery, McGaw Northwestern University Medical Center, Chicago, Illinois, USA
| | - Brian J Cole
- Department of Orthopedics, Rush University Medical Center, Chicago, Illinois, USA
| | - Rachel M Frank
- Department of Orthopedic Surgery, University of Colorado School of Medicine, Aurora, Colorado, USA
| |
Collapse
|
14
|
Cells, soluble factors and matrix harmonically play the concert of allograft integration. Knee Surg Sports Traumatol Arthrosc 2019; 27:1717-1725. [PMID: 30291395 DOI: 10.1007/s00167-018-5182-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Accepted: 09/20/2018] [Indexed: 01/05/2023]
Abstract
Implantation of allograft tissues has massively grown over the last years, especially in the fields related to sports medicine. Beside the fact that often no autograft option exists, autograft related disadvantages as donor-site morbidity and prolonged operative time are drastically reduced with allograft tissues. Despite the well documented clinical success for bone allograft procedures, advances in tissue engineering raised the interest in meniscus, osteochondral and ligament/tendon allografts. Notably, their overall success rates are constantly higher than 80%, making them a valuable treatment option in orthopaedics, especially in knee surgery. Complications reported for allografting procedures are a small risk of disease transmission, immunologic rejection, and decreased biologic incorporation together with nonunion at the graft-host juncture and, rarely, massive allograft resorption. Although allografting is a successful procedure, improved techniques and biological knowledge to limit these pitfalls and maximize graft incorporation are needed. A basic understanding of the biologic processes that affect the donor-host interactions and eventual incorporation and remodelling of various allograft tissues is a fundamental prerequisite for their successful clinical use. Further, the importance of the interaction of immunologic factors with the biologic processes involved in allograft incorporation has yet to be fully dissected. Finally, new tissue engineering techniques and use of adjunctive growth factors, cell based and focused gene therapies may improve the quality and uniformity of clinical outcomes. The aim of this review is to shed light on the biology of meniscus, osteochondral and ligament/tendon allograft incorporation and how collection and storage techniques may affect graft stability and embodiment.Level of evidence V.
Collapse
|
15
|
Tisherman R, Wilson K, Horvath A, Byrne K, De Groot J, Musahl V. Allograft for knee ligament surgery: an American perspective. Knee Surg Sports Traumatol Arthrosc 2019; 27:1882-1890. [PMID: 30888445 DOI: 10.1007/s00167-019-05425-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Accepted: 02/15/2019] [Indexed: 11/25/2022]
Abstract
PURPOSE Allografts are frequently use for ligamentous reconstruction at the knee. In the United States, tissue donation and distribution are highly regulated processes with thorough oversight from private and government entities. Allograft is widely available in the United States and allograft procurement is a large industry with varying procurement, sterilization, processing, and distribution procedures. It is important to understand allograft regulation and processing which may affect graft mechanical properties and biological graft integration. METHODS English-language literature, United States government and regulatory agency statues pertaining to allograft procurement, distribution, and usage were reviewed and the findings summarized. RESULTS During the processing of allograft, multiple factors including sterilization procedures, irradiation, storage conditions, and graft type all affect the biomechanical properties of the allograft tissue. Biological incorporation and ligamentization of allograft does occur, but at a slower rate compared with autograft. For ligamentous reconstruction around the knee, allograft offers shorter operative time, no donor-site morbidity, but has shown an increased risk for graft failure compared to autograft. CONCLUSION This article reviews the regulations on graft tissue within the United States, factors affecting the biomechanics of allograft tissue, differences in allograft tissue choices, and the use of allograft for anterior cruciate ligament reconstruction and multiligamentous knee injury reconstruction. LEVEL OF EVIDENCE V.
Collapse
Affiliation(s)
- Robert Tisherman
- Department of Orthopaedic Surgery, University of Pittsburgh, 3471 Fifth Avenue Suite 1010, Pittsburgh, PA, 15213, USA.
| | - Kevin Wilson
- Department of Orthopaedic Surgery, University of Pittsburgh, 3471 Fifth Avenue Suite 1010, Pittsburgh, PA, 15213, USA
| | - Alexandra Horvath
- Department of Orthopaedics, Institute of Clinical Sciences, The Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - Kevin Byrne
- Department of Orthopaedic Surgery, University of Pittsburgh, 3471 Fifth Avenue Suite 1010, Pittsburgh, PA, 15213, USA
| | - Joseph De Groot
- Department of Orthopaedic Surgery, University of Pittsburgh, 3471 Fifth Avenue Suite 1010, Pittsburgh, PA, 15213, USA
| | - Volker Musahl
- Department of Orthopaedic Surgery, University of Pittsburgh, 3471 Fifth Avenue Suite 1010, Pittsburgh, PA, 15213, USA
| |
Collapse
|
16
|
Yang X, Feng J, Wang F, Hu Y. Irradiation sterilization used for allogenetic tendon: a literature review of current concept. Cell Tissue Bank 2019; 20:129-139. [PMID: 31054008 DOI: 10.1007/s10561-019-09756-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2018] [Accepted: 02/13/2019] [Indexed: 01/27/2023]
Abstract
Tendon injury is a very common type of sports trauma, and its incidence has increased over the past decades. Surgical reconstruction with tendon allograft has been increasingly used to restore the motor function and stability of the injured site. However, the risk of disease transmission caused by allogeneic tendon transplantation has been a major problem for tissue bank researchers and clinicians. In order to eliminate the risk of disease transmission, a process of terminal sterilization is necessary. Ionizing irradiation, including gamma irradiation and electron beam irradiation is the most commonly used method for the terminal sterilization, which has been widely proved to be able to effectively inactivate the contained pathogens. Nevertheless, some accompanying damage to the mechanical and histological properties of collagen fibers in tendons will be caused. Therefore, more and more studies have begun to pay attention to the protective effect of radiation protection agents, including the radical scavengers and cross-linking agents, in the irradiation sterilization of allogeneic tendons.
Collapse
Affiliation(s)
- Xionggang Yang
- Graduate School, Tianjin Medical University, Tianjin, 300070, China
| | - Jiangtao Feng
- Graduate School, Tianjin Medical University, Tianjin, 300070, China
| | - Feng Wang
- Graduate School, Tianjin Medical University, Tianjin, 300070, China
| | - Yongcheng Hu
- Department of Orthopedic Oncology, Tianjin Hospital, Tianjin, 300211, China.
| |
Collapse
|
17
|
Erivan R, Aubret S, Villatte G, Cueff R, Mulliez A, Descamps S, Boisgard S. Irradiation at 11 kGy conserves the biomechanical properties of fascia lata better than irradiation at 25 kGy. Clin Biomech (Bristol, Avon) 2018; 60:100-107. [PMID: 30340149 DOI: 10.1016/j.clinbiomech.2018.10.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Revised: 08/24/2018] [Accepted: 10/11/2018] [Indexed: 02/07/2023]
Abstract
The objective of this study was to determine the biomechanical properties of the fascia lata and the effects of three preservation methods: freezing, cryopreservation with dimethylsulfoxide solution and lyophilization; and to compare the effects of low-dose (11 kGy) and normal-dose (25 kGy) gamma-ray sterilization versus no irradiation. 248 samples from 14 fasciae latae were collected. Freezing samples were frozen at -80 °C. Cryopreservation with dimethylsulfoxide solution samples were frozen with 10 cl dimethylsulfoxide solution at -80 °C. Lyophilization samples were frozen at -22 °C and lyophilized. Each preservation group were then randomly divided into 3 irradiation groups. The cryopreservation with dimethylsulfoxide solution samples had significantly worse results in all 3 irradiation conditions. Young's modulus was lower for the freezing samples (p < 0.001) and lyophilization samples groups (p < 0.001). Tear deformation was lower for the freezing samples (p = 0.001) and lyophilization samples groups (p = 0.003), as was stress at break (p < 0.001 and p < 0.001). Taking all preservation methods together, samples irradiated at 25 kGy had worse results than the 0 kGy and 11 kGy groups in terms of Young's modulus (p = 0.007 and p = 0.13) and of stress at break (p = 0.006 and p = 0.06). The biomechanical properties of fascia lata allografts were significantly worse under dimethylsulfoxide cryopreservation. The deleterious effects of irradiation were dose-dependent.
Collapse
Affiliation(s)
- Roger Erivan
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, F-63000 Clermont-Ferrand, France.
| | - Sylvain Aubret
- Université Clermont Auvergne, CHU Clermont-Ferrand, F-63000 Clermont-Ferrand, France
| | - Guillaume Villatte
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, F-63000 Clermont-Ferrand, France
| | - Régis Cueff
- Université Clermont Auvergne, CNRS, SIGMA Clermont, ICCF, F-63000 Clermont-Ferrand, France
| | - Aurélien Mulliez
- Délégation à la Recherche Clinique et aux Innovations (DRCI), CHU Clermont-Ferrand, F-63000 Clermont-Ferrand, France
| | - Stéphane Descamps
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, F-63000 Clermont-Ferrand, France
| | - Stéphane Boisgard
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, F-63000 Clermont-Ferrand, France
| |
Collapse
|
18
|
Harrell CR, Djonov V, Fellabaum C, Volarevic V. Risks of Using Sterilization by Gamma Radiation: The Other Side of the Coin. Int J Med Sci 2018; 15:274-279. [PMID: 29483819 PMCID: PMC5820857 DOI: 10.7150/ijms.22644] [Citation(s) in RCA: 76] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2017] [Accepted: 12/21/2017] [Indexed: 12/30/2022] Open
Abstract
The standard sterilization method for most medical devices over the past 40 years involves gamma irradiation. During sterilization, gamma rays efficiently eliminate microorganisms from the medical devices and tissue allografts, but also significantly change molecular structure of irradiated products, particularly fragile biologics such as cytokines, chemokines and growth factors. Accordingly, gamma radiation significantly alters biomechanical properties of bone, tendon, tracheal, skin, amnion tissue grafts and micronized amniotic membrane injectable products. Similarly, when polymer medical devices are sterilized by gamma radiation, their physico-chemical characteristics undergo modification significantly affecting their clinical use. Several animal studies demonstrated that consummation of irradiated food provoked genome instability raising serious concerns regarding oncogenic potential of irradiated consumables. These findings strongly suggest that new, long-term, prospective clinical studies should be conducted in near future to investigate whether irradiated food is safe for human consumption. In this review, we summarized current knowledge regarding molecular mechanisms responsible for deleterious effects of gamma radiation with focusing on its significance for food safety and biomechanical characteristics of medical devices, and tissue allografts, especially injectable biologics.
Collapse
Affiliation(s)
- C Randall Harrell
- Regenerative Processing Plant, LLC, Palm Harbor, Florida, United States of America
| | | | - Crissy Fellabaum
- Regenerative Processing Plant, LLC, Palm Harbor, Florida, United States of America
| | - Vladislav Volarevic
- Department of Microbiology and Immunology, Center for Molecular Medicine and Stem Cell Research, Faculty of Medical Sciences, University of Kragujevac, Kragujevac, Serbia
| |
Collapse
|
19
|
What Factors Influence the Biomechanical Properties of Allograft Tissue for ACL Reconstruction? A Systematic Review. Clin Orthop Relat Res 2017; 475:2412-2426. [PMID: 28353048 PMCID: PMC5599386 DOI: 10.1007/s11999-017-5330-9] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Allograft tissue is used in 22% to 42% of anterior cruciate ligament (ACL) reconstructions. Clinical outcomes have been inconsistent with allograft tissue, with some series reporting no differences in outcomes and others reporting increased risk of failure. There are numerous variations in processing and preparation that may influence the eventual performance of allograft tissue in ACL reconstruction. We sought to perform a systematic review to summarize the factors that affect the biomechanical properties of allograft tissue for use in ACL reconstruction. Many factors might impact the biomechanical properties of allograft tissue, and these should be understood when considering using allograft tissue or when reporting outcomes from allograft reconstruction. QUESTIONS/PURPOSES What factors affect the biomechanical properties of allograft tissue used for ACL reconstruction? METHODS We performed a systematic review to identify studies on factors that influence the biomechanical properties of allograft tissue through PubMed and SCOPUS databases. We included cadaveric and animal studies that reported on results of biomechanical testing, whereas studies on fixation, histologic evaluation, and clinical outcomes were excluded. There were 319 unique publications identified through the search with 48 identified as relevant to answering the study question. For each study, we recorded the type of tissue tested, parameters investigated, and the effects on biomechanical behavior, including load to failure and stiffness. Primary factors identified to influence allograft tissue properties were graft tissue type, sterilization methods (irradiation and chemical processing), graft preparation, donor parameters, and biologic adjuncts. RESULTS Load to failure and graft stiffness varied across different tissue types, with nonlooped tibialis grafts exhibiting the lowest values. Studies on low-dose irradiation showed variable effects, whereas high-dose irradiation consistently produced decreased load to failure and stiffness values. Various chemical sterilization measures were also associated with negative effects on biomechanical properties. Prolonged freezing decreased load to failure, ultimate stress, and ultimate strain. Up to eight freeze-thaw cycles did not lead to differences in biomechanical properties of cadaveric grafts. Regional differences were noted in patellar tendon grafts, with the central third showing the highest load to failure and stiffness. Graft diameter strongly contributed to load-to-failure measurements. Age older than 40 years, and especially older than 65 years, negatively impacted biomechanical properties, whereas gender had minimal effect on the properties of allograft tissue. Biologic adjuncts show potential for improving in vivo properties of allograft tissue. CONCLUSIONS Future clinical studies on allograft ACL reconstruction should investigate in vivo graft performance with standardized allograft processing and preparation methods that limit the negative effects on the biomechanical properties of tissue. Additionally, biologic adjuncts may improve the biomechanical properties of allograft tissue, although future preclinical and clinical studies are necessary to clarify the role of these treatments. CLINICAL RELEVANCE Based on the findings of this systematic review that emphasize biomechanical properties of ACL allografts, surgeons should favor the use of central third patellar tendon or looped soft tissue grafts, maximize graft cross-sectional area, and favor grafts from donors younger than 40 years of age while avoiding grafts subjected to radiation doses > 20 kGy, chemical processing, or greater than eight freeze-thaw cycles.
Collapse
|
20
|
Lording T, Steiner J, Hewison C, Neyret P, Lustig S. Autograft superior to both irradiated and non-irradiated allograft for primary ACL reconstruction: a systematic review. J ISAKOS 2017. [DOI: 10.1136/jisakos-2016-000100] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
21
|
Zhang Y, He F, Li D, Wang D. Effects of high temperature steam treatment on microbial and phytochemical contents, antioxidant activities, chemical stability, and shelf life of oral liquid prepared from the leaves ofZanthoxylum bungeanumMaxim. J FOOD PROCESS PRES 2017. [DOI: 10.1111/jfpp.13180] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Affiliation(s)
- Yawei Zhang
- College of Forestry; Northwest A&F University; Yangling Shaanxi 712100 China
| | - Fengyuan He
- College of Forestry; Northwest A&F University; Yangling Shaanxi 712100 China
| | - Dengwu Li
- College of Forestry; Northwest A&F University; Yangling Shaanxi 712100 China
| | - Dongmei Wang
- College of Forestry; Northwest A&F University; Yangling Shaanxi 712100 China
| |
Collapse
|
22
|
Does sterilization with fractionated electron beam irradiation prevent ACL tendon allograft from tissue damage? Knee Surg Sports Traumatol Arthrosc 2017; 25:584-594. [PMID: 27438006 DOI: 10.1007/s00167-016-4240-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Accepted: 07/06/2016] [Indexed: 01/27/2023]
Abstract
PURPOSE Allografts are frequently used for anterior cruciate ligament (ACL) reconstruction. However, due to the inherent risk of infection, a method that achieves complete sterilization of grafts is warranted without impairing their biomechanical properties. Fractionation of electron beam (FEbeam) irradiation has been shown to maintain similar biomechanical properties compared to fresh-frozen allografts (FFA) in vitro. Therefore, aim of this study was to evaluate the biomechanical properties and early remodelling of grafts that were sterilized with fractionated high-dose electron beam irradiation in an in vivo sheep model. METHODS ACL reconstruction was performed in 18 mature merino mix sheep. Sixteen were reconstructed with allografts sterilized with FEbeam irradiation (8 × 3.4 kGy) and two with FFA. Eight FFA from prior studies with identical surgical reconstruction and biomechanical and histological analyzes served as controls. Half of the animals were sacrificed at 6 and 12 weeks, and biomechanical testing was performed. Anterior-posterior laxity (APL) was assessed with an AP drawer test at 60° flexion, and load to failure testing was carried out. Histological evaluation of mid-substance samples was performed for descriptive analysis, cell count, crimp and vessel density. For statistical analysis a Kruskal-Wallis test was used for overall group comparison followed by a Mann-Whitney U test for pairwise comparison of the histological and biomechanical parameters. RESULTS Biomechanical testing showed significantly decreased stiffness in FEbeam compared to FFA at both time points (p ≤ 0.004). APL was increased in FEbeam compared to FFA, which was significant at 6 weeks (p = 0.004). Median of failure loads was decreased in FEbeam grafts, with 12 reconstructions already failing during cyclic loading. Vessel density was decreased in FEbeam compared to FFA at both time points, with significant differences at 12 weeks (p = 0.015). Crimp length was significantly shorter in FEbeam compared to FFA at both time points (p ≤ 0.004) and decreased significantly in both groups from 6 to 12 weeks (p ≤ 0.025). CONCLUSION ACL reconstruction with fractionated Ebeam sterilization significantly alters the biomechanical properties and the early remodelling process of treated grafts in vivo. Therefore, this sterilization method cannot be recommended for clinical application. As substantial changes in the remodelling are inherent in this study, care in the rehabilitation of even low-dose sterilized allografts, used for ACL reconstruction, is recommended.
Collapse
|
23
|
Hangody G, Szebényi G, Abonyi B, Kiss R, Hangody L, Pap K. Does a different dose of gamma irradiation have the same effect on five different types of tendon allografts? - a biomechanical study. INTERNATIONAL ORTHOPAEDICS 2016; 41:357-365. [PMID: 27847977 DOI: 10.1007/s00264-016-3336-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2016] [Accepted: 10/31/2016] [Indexed: 01/29/2023]
Abstract
INTRODUCTION The goals of our study were to evaluate the biomechanical differences between five tendons and the changes in biomechanical properties caused by irradiation. METHODS Achilles, quadriceps, semitendinosus + gracilis (STG), tibialis anterior (TA) and the peroneus longus (PL) were harvested from 30 donors. Group A contained 50 tendons without gamma irradiation. The groups were irradiated with a dose of 21 kGy (group B 50 tendons) and with a dose of 42 kGy (group C 50 tendons). The grafts were soaked in a radio-protectant solution and frozen at -80 °C. Cyclic loading tests were performed followed by load to failure tests. Young modulus of elasticity, maximum force, strain at tensile strength and strain at rupture were calculated. RESULTS The Achilles tendons had significantly lower Young modulus than the TA (p = 0.0036) in group A. The Achilles showed significantly lower than PL (p = 0.000042) and TA (p = 0.00142) in group B and C. The quadriceps and the ST (p = 0.0037) provided poorer values than the TA (p = 0.0432) in group C. We found no difference in maximum loads among the tendons in group A. The maximum load of the Achilles and quadriceps showed better results than the PL (p = 0.0016), (p = 0.0018) and the STG (p = 0.0066), (p = 0.0019) in group C. The TA had similar results like the Achilles and quadriceps. DISCUSSION AND CONCLUSIONS The vulnerability of gamma irradiation of TA was less than Achilles and quadriceps tendons.
Collapse
Affiliation(s)
- Gyorgy Hangody
- Department of Orthopedics and Traumatology, Uzsoki Hospital, Uzsoki Street 29-41, 1145, Budapest, Hungary
| | - Gábor Szebényi
- Cooperation Research Center for Biomechanics, Budapest University of Technology and Economics, Bertalan Lajos Street 2, 1111, Budapest, Hungary
| | - Bence Abonyi
- Department of Orthopedics and Traumatology, Uzsoki Hospital, Uzsoki Street 29-41, 1145, Budapest, Hungary
| | - Rita Kiss
- Cooperation Research Center for Biomechanics, Budapest University of Technology and Economics, Bertalan Lajos Street 2, 1111, Budapest, Hungary
| | - László Hangody
- Department of Orthopedics and Traumatology, Uzsoki Hospital, Uzsoki Street 29-41, 1145, Budapest, Hungary
- Department of Traumatology, Semmelweis University, Uzsoki Street 29-41, 1145, Budapest, Hungary
| | - Károly Pap
- Department of Orthopedics and Traumatology, Uzsoki Hospital, Uzsoki Street 29-41, 1145, Budapest, Hungary.
- Department of Traumatology, Semmelweis University, Uzsoki Street 29-41, 1145, Budapest, Hungary.
| |
Collapse
|
24
|
DiBartola AC, Everhart JS, Kaeding CC, Magnussen RA, Flanigan DC. Maximum load to failure of high dose versus low dose gamma irradiation of anterior cruciate ligament allografts: A meta-analysis. Knee 2016; 23:755-62. [PMID: 27297938 DOI: 10.1016/j.knee.2016.05.012] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2016] [Revised: 05/16/2016] [Accepted: 05/22/2016] [Indexed: 02/02/2023]
Abstract
BACKGROUND The objective of this study was to systematically evaluate the existing literature to compare the biomechanical effects of low dose and high dose gamma irradiation on commonly used ACL allografts. METHODS A systematic search was performed in PubMed, Cumulative Index for Nursing and Allied Health Literature (CINAHL), Cochrane Reviews, SCOPUS, and SportDiscus. Nine studies were identified that met the following inclusion criteria: 1) controlled laboratory study, 2) investigation of standard allografts for anterior cruciate ligament reconstruction (ACLR), 3) gamma irradiation (dose reported) and a negative control group, and 4) mechanical loading (results reported). RESULTS Nine studies met all inclusion and exclusion criteria. There was a dose-dependent relationship between radiation and decreased mechanical tendon integrity. Low dose radiation (<2.5Mrad [Mrad]) showed graft weakening with an average of 4.3% decrease in load to failure (standardized mean difference [SMD], 0.23; 95% CI 0.216, 0.68; p=0.31), whereas high-dose radiation showed a significantly larger (32.4% average) decrease in load to failure (SMD, 1.79; 95% CI 1.194, 2.38; p<0.001). CONCLUSIONS Gamma irradiation has a negative effect on tendon allograft strength that is dose-dependent, with particularly large effects noted at irradiation doses of ≥2.5Mrad.
Collapse
Affiliation(s)
- Alex C DiBartola
- The Ohio State University College of Medicine, Columbus, OH, USA; Division of Sports Medicine, Department of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Joshua S Everhart
- Division of Sports Medicine, Department of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Christopher C Kaeding
- Division of Sports Medicine, Department of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, OH, USA; Sports Medicine, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Robert A Magnussen
- Division of Sports Medicine, Department of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, OH, USA; Sports Medicine, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - David C Flanigan
- Division of Sports Medicine, Department of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, OH, USA; Sports Medicine, The Ohio State University Wexner Medical Center, Columbus, OH, USA.
| |
Collapse
|
25
|
Gut G, Marowska J, Jastrzebska A, Olender E, Kamiński A. Structural mechanical properties of radiation-sterilized human Bone-Tendon-Bone grafts preserved by different methods. Cell Tissue Bank 2015; 17:277-87. [PMID: 26679928 PMCID: PMC4882344 DOI: 10.1007/s10561-015-9538-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2015] [Accepted: 12/08/2015] [Indexed: 01/28/2023]
Abstract
To avoid the risk of infectious disease transmission from donor to recipient, allografts should be terminally sterilized. In the previous paper (Kaminski et al. in Cell Tissue Bank 10:215–219, 2009) we presented the effect of various methods of preservation (deep fresh freezing, glycerolization, lyophilization), followed by irradiation with different doses of electron beam (EB), on material (intrinsic) mechanical properties of human patellar tendons cut out as for anterior cruciate ligament reconstruction, obtained in failure tensile test. As structural mechanical properties are equally important to predict the behaviour of the graft as a whole functional unit, the purpose of the present paper was to show the results for failure load and elongation, obtained in the same experiment. Paired Bone-Tendon-Bone grafts (BTB) were prepared from cadaveric human patella tendons with both patellar and tibial attachments. They were preserved by deep freezing, glycerolization or lyophilization and subsequently EB-irradiated with the doses of 25, 35, 50 or 100 kGy (fresh-frozen grafts) or a single dose of 35 kGy (glycerolized and lyophilized grafts). Each experimental (irradiated) group was provided with control (non-irradiated), donor-matched group. The specimens from all groups were subjected to mechanical failure tensile test with the use of Instron system in order to measure their structural properties (failure load and elongation). All lyophilized grafts were rehydrated before mechanical testing. In our study we did not observe significant deterioration of structural mechanical properties of BTB grafts processed by fresh-freezing and then terminal sterilized with growing doses of EB up to 100 kGy. In contrast, BTB grafts processed by glycerolization or lyophilization and irradiated with 35 kGy showed significant decrease of failure load. Obtained results suggest that deep-frozen irradiated grafts retain their initial mechanical properties to an extent which does not exclude their clinical application. However, biomechanical investigations constitute only the first step to evaluate the potential clinical usefulness of such allografts and further extensive in vivo studies are needed.
Collapse
Affiliation(s)
- Grzegorz Gut
- Department of Transplantology and Central Tissue Bank, Medical University of Warsaw, Ul. Chalubinskiego 5, 02-004, Warsaw, Poland. .,National Centre for Tissue and Cell Banking, Chalubinskiego 5, 02-004, Warsaw, Poland.
| | - Joanna Marowska
- National Centre for Tissue and Cell Banking, Chalubinskiego 5, 02-004, Warsaw, Poland
| | - Anna Jastrzebska
- National Centre for Tissue and Cell Banking, Chalubinskiego 5, 02-004, Warsaw, Poland
| | - Ewa Olender
- Department of Transplantology and Central Tissue Bank, Medical University of Warsaw, Ul. Chalubinskiego 5, 02-004, Warsaw, Poland.,National Centre for Tissue and Cell Banking, Chalubinskiego 5, 02-004, Warsaw, Poland
| | - Artur Kamiński
- Department of Transplantology and Central Tissue Bank, Medical University of Warsaw, Ul. Chalubinskiego 5, 02-004, Warsaw, Poland.,National Centre for Tissue and Cell Banking, Chalubinskiego 5, 02-004, Warsaw, Poland
| |
Collapse
|
26
|
Tejwani SG, Chen J, Funahashi TT, Love R, Maletis GB. Revision Risk After Allograft Anterior Cruciate Ligament Reconstruction: Association With Graft Processing Techniques, Patient Characteristics, and Graft Type. Am J Sports Med 2015; 43:2696-705. [PMID: 26068037 DOI: 10.1177/0363546515589168] [Citation(s) in RCA: 74] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Allograft tissue is a common graft choice for anterior cruciate ligament reconstruction (ACLR). Allograft sterilization methods vary widely across numerous commercial tissue vendors. Multiple studies, despite being limited in sample size, have suggested a higher rate of clinical failure associated with the use of allograft tissue in ACLR when compared with autograft. PURPOSE To examine the association of graft processing techniques, patient characteristics, and graft type with risk of revision surgery after allograft ACLR. STUDY DESIGN Cohort study; Level of evidence, 3. METHODS A retrospective cohort study was conducted that used an integrated United States health care system's ACLR registry to identify primary unilateral cases in which allografts were used. Aseptic revision was the endpoint of the study. Allograft type, processing methods (irradiation dose, AlloWash, AlloTrue, BioCleanse), and graft donor age were assessed as potential risk factors for revision, with adjustment for patient age, sex, and body mass index (BMI) by use of survival analysis. Hazard ratios (HR) and 95% confidence intervals (CIs) were calculated. RESULTS A total of 5968 primary ACLR cases with allograft were included in the study, of which 3688 (61.8%) were male patients. The median age of the cohort at the time of surgery was 34.1 years (interquartile range, 24.1-42.9 years). The mean time to follow-up (±SD) was 2.1 ± 1.5 years. There were 3751 (62.9%) allograft ACLRs using soft tissue, 1188 (19.9%) with Achilles tendon, and 1029 (17.2%) with bone-patellar tendon-bone (BPTB). Graft processing groups included BioCleanse (n = 367), AlloTrue or AlloWash (n = 2278), irradiation greater than 1.8 Mrad (n = 1146), irradiation up to 1.8 Mrad (n = 3637), and no irradiation (n = 1185). There were 156 (2.6%) aseptic revisions. After adjustment for patient age, sex, and BMI, the use of BioCleanse (HR = 2.45; 95% CI, 1.36-4.40) and irradiation greater than 1.8 Mrad (HR = 1.64; 95% CI, 1.08-2.49) were associated with a higher risk of revision when compared with all other methods of processing. BPTB allografts were at higher risk of revision (HR = 1.79; 95% CI, 1.20-2.66) when compared with soft tissue allografts. Conversely, with every 5-year increase in age, the risk of revision was 0.67 (95% CI, 0.61-0.73) times lower. Male patients were found to be at higher risk of revision when compared with females (HR = 1.47; 95% CI, 1.04-2.07). The use of AlloWash or AlloTrue processing, patient BMI, and graft donor age did not affect revision rate significantly. CONCLUSION In the largest known study of its kind examining outcome after primary allograft ACLR, graft irradiation greater than 1.8 Mrad, BioCleanse graft processing, younger patient age, male patients, and BPTB allograft were all associated with a higher risk of clinical failure and subsequent revision surgery.
Collapse
Affiliation(s)
| | - Jason Chen
- Kaiser Permanente, San Diego, California, USA
| | | | | | | |
Collapse
|