1
|
Waegenaar F, García-Timermans C, Van Landuyt J, De Gusseme B, Boon N. Impact of operational conditions on drinking water biofilm dynamics and coliform invasion potential. Appl Environ Microbiol 2024; 90:e0004224. [PMID: 38647288 PMCID: PMC11107155 DOI: 10.1128/aem.00042-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 03/27/2024] [Indexed: 04/25/2024] Open
Abstract
Biofilms within drinking water distribution systems serve as a habitat for drinking water microorganisms. However, biofilms can negatively impact drinking water quality by causing water discoloration and deterioration and can be a reservoir for unwanted microorganisms. In this study, we investigated whether indicator organisms for drinking water quality, such as coliforms, can settle in mature drinking water biofilms. Therefore, a biofilm monitor consisting of glass rings was used to grow and sample drinking water biofilms. Two mature drinking water biofilms were characterized by flow cytometry, ATP measurements, confocal laser scanning microscopy, and 16S rRNA sequencing. Biofilms developed under treated chlorinated surface water supply exhibited lower cell densities in comparison with biofilms resulting from treated groundwater. Overall, the phenotypic as well as the genotypic characteristics were significantly different between both biofilms. In addition, the response of the biofilm microbiome and possible biofilm detachment after minor water quality changes were investigated. Limited changes in pH and free chlorine addition, to simulate operational changes that are relevant for practice, were evaluated. It was shown that both biofilms remained resilient. Finally, mature biofilms were prone to invasion of the coliform, Serratia fonticola. After spiking low concentrations (i.e., ±100 cells/100 mL) of the coliform to the corresponding bulk water samples, the coliforms were able to attach and get established within the mature biofilms. These outcomes emphasize the need for continued research on biofilm detachment and its implications for water contamination in distribution networks. IMPORTANCE The revelation that even low concentrations of coliforms can infiltrate into mature drinking water biofilms highlights a potential public health concern. Nowadays, the measurement of coliform bacteria is used as an indicator for fecal contamination and to control the effectiveness of disinfection processes and the cleanliness and integrity of distribution systems. In Flanders (Belgium), 533 out of 18,840 measurements exceeded the established norm for the coliform indicator parameter in 2021; however, the source of microbial contamination is mostly unknown. Here, we showed that mature biofilms, are susceptible to invasion of Serratia fonticola. These findings emphasize the importance of understanding and managing biofilms in drinking water distribution systems, not only for their potential to influence water quality, but also for their role in harboring and potentially disseminating pathogens. Further research into biofilm detachment, long-term responses to operational changes, and pathogen persistence within biofilms is crucial to inform strategies for safeguarding drinking water quality.
Collapse
Affiliation(s)
- Fien Waegenaar
- Department of Biotechnology, Center for Microbial Ecology and Technology (CMET), Ghent University, Ghent, Belgium
- Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Ghent, Belgium
| | - Cristina García-Timermans
- Department of Biotechnology, Center for Microbial Ecology and Technology (CMET), Ghent University, Ghent, Belgium
- Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Ghent, Belgium
| | - Josefien Van Landuyt
- Department of Biotechnology, Center for Microbial Ecology and Technology (CMET), Ghent University, Ghent, Belgium
- Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Ghent, Belgium
| | - Bart De Gusseme
- Department of Biotechnology, Center for Microbial Ecology and Technology (CMET), Ghent University, Ghent, Belgium
- Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Ghent, Belgium
- Farys, Department R&D – Innovation Water, Ghent, Belgium
| | - Nico Boon
- Department of Biotechnology, Center for Microbial Ecology and Technology (CMET), Ghent University, Ghent, Belgium
- Center for Advanced Process Technology for Urban Resource Recovery (CAPTURE), Ghent, Belgium
| |
Collapse
|
2
|
Zhang W, Jia H, Wang Y, Gao F, Yang G, Wang J. Review in application of blast furnace dust in wastewater treatment: material preparation, integrated process, and mechanism. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:22339-22361. [PMID: 38433174 DOI: 10.1007/s11356-024-32631-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Accepted: 02/20/2024] [Indexed: 03/05/2024]
Abstract
Blast furnace dust (BFD) is the solid powder and particulate matter produced by dust removal process in ironmaking industry. The element composition of BFD is complex, and a direct return to sintering will lead to heavy metal enrichment and blast furnace lining corrosion. In recent years, the application of BFD in wastewater treatment has attracted widespread attention. Based on the mechanisms of action of BFD in wastewater, this paper discusses in detail the application of BFD in iron-carbon micro-electrolysis, biological enhancement, adsorption, flocculation, and Fenton/Fenton-like reactions. Iron oxides and carbon in BFD are key substances. Thus, BFD has great potential as a raw material in wastewater treatment, and the waste utilization of BFD can be realized. However, the difference in elements and composition of BFD limits its large-scale application. We can classify BFD according to different proportions of elements. In the future, it is necessary to focus on the service life of BFD in water and whether it shall bring secondary pollution to water.
Collapse
Affiliation(s)
- Wen Zhang
- State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin, 300387, China
- School of Environmental Science and Engineering, Tiangong University, Tianjin, 300387, China
| | - Hui Jia
- State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin, 300387, China
- School of Environmental Science and Engineering, Tiangong University, Tianjin, 300387, China
| | - Yue Wang
- State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin, 300387, China
- School of Environmental Science and Engineering, Tiangong University, Tianjin, 300387, China
| | - Fei Gao
- State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin, 300387, China
- School of Environmental Science and Engineering, Tiangong University, Tianjin, 300387, China
| | - Guang Yang
- State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin, 300387, China
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, China
| | - Jie Wang
- State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin, 300387, China.
- School of Environmental Science and Engineering, Tiangong University, Tianjin, 300387, China.
- Cangzhou Institute of Tiangong University, Cangzhou, 061000, China.
| |
Collapse
|
3
|
Chen WT, Chien CC, Ho WS, Ou JH, Chen SC, Kao CM. Effects of treatment processes on AOC removal and changes of bacterial diversity in a water treatment plant. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 311:114853. [PMID: 35276566 DOI: 10.1016/j.jenvman.2022.114853] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 02/27/2022] [Accepted: 03/04/2022] [Indexed: 06/14/2023]
Abstract
The effectiveness of different treatment processes on assimilable organic carbon (AOC) removal and bacterial diversity variations was evaluated in a water treatment plant. The van der Kooij technique was applied for AOC analysis and responses of bacterial communities were characterized by the metagenomics assay. Results show that the AOC concentrations were about 93, 148, 43, 51, 37, and 38 μg acetate-C/L in effluents of raw water basin, preozonation, rapid sand filtration (RSF), ozonation, biofiltration [biological activated carbon (BAC) filtration], and chlorination (clear water), respectively. Increased AOC concentrations were observed after preozonation, ozonation, and chlorination units due to the production of biodegradable organic matters after the oxidation processes. Results indicate that the oxidation processes were the main causes of AOC formation, which resulted in significant increases in AOC concentrations (18-59% increment). The AOC removal efficiencies were 47, 28, and 60% in the RSF, biofiltration, and the whole system, respectively. RSF and biofiltration were responsible for the AOC treatment and both processes played key roles in AOC removal. Thus, both RSF and biofiltration processes would contribute to AOC treatment after oxidation. Sediments from the raw water basin and filter samples from RSF and BAC units were collected and analyzed for bacterial communities. Results from scanning electron microscope analysis indicate that bacterial colonization was observed in filter materials. This indicates that the surfaces of the filter materials were beneficial to bacterial growth and AOC removal via the adsorption and biodegradation mechanisms. Next generation sequencing analyses demonstrate that water treatment processes resulted in the changes of bacterial diversity and community profiles in filters of RSF and BAC. According to the findings of bacterial composition and interactions, the dominant bacterial phyla were Proteobacteria (41% in RSF and 56% in BAC) followed by Planctomycetes and Acidobacteria in RSF and BAC systems, which might affect the AOC biodegradation efficiency. Results would be useful in developing AOC treatment and management processes in water treatment plants.
Collapse
Affiliation(s)
- W T Chen
- Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - C C Chien
- Graduate School of Biotechnology and Bioengineering, Yuan Ze University, Chung-Li City, Taoyuan, Taiwan
| | - W S Ho
- Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - J H Ou
- Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - S C Chen
- Department of Life Sciences, National Central University, Taoyuan, Taiwan.
| | - C M Kao
- Institute of Environmental Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan.
| |
Collapse
|
4
|
Li J, Chen X, Yang Z, Liu Z, Chen Y, Wang YE, Xie H. Denitrification performance and mechanism of sequencing batch reactor with a novel iron-polyurethane foam composite carrier. Biochem Eng J 2021. [DOI: 10.1016/j.bej.2021.108209] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
5
|
Kaur L, Rishi MS, Arora NK. Deciphering pollution vulnerability zones of River Yamuna in relation to existing land use land cover in Panipat, Haryana, India. ENVIRONMENTAL MONITORING AND ASSESSMENT 2021; 193:120. [PMID: 33570684 DOI: 10.1007/s10661-020-08832-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 12/27/2020] [Indexed: 06/12/2023]
Abstract
Rivers are one of the major freshwater resources, which provide water for irrigation, domestic, recreational, environmental, and industrial purposes, but they are extremely vulnerable to pollution due to discharge of untreated waste. Establishing the baseline river water quality data is important, so that monitoring changes over time, assessing impacts of particular developmental projects and setting water quality standards for the protection of the river, can be undertaken. In the present study, water quality assessment was done for a segment of Yamuna River passing through Panipat district, Haryana, India. This study is an attempt to know the impact of wastewater generated due to urban and industrial activities taking place in Panipat city and nearby areas, on River Yamuna. Furthermore, vulnerability zone of River Yamuna was delineated using CCME-WQI, NSF-WQI, and hierarchical cluster analysis (HCA). The water quality samples were further evaluated for the agricultural and industrial purposes to determine whether the water can be used for irrigation and industrial requirements. The study also considered the existing land use land cover (LULC) on left and right banks of the River Yamuna and the wastewater carrying drain. River Yamuna travels nearly a distance of ≈ 44 Kms in and around Panipat district and the results of the study indicated that nearly 13 Km stretch of River is more vulnerable to pollution. Thus, it is suggested that wastewater discharge regulation, installation of effluent treatments plants, and maintenance of environmental flow are prerequisite to protect and restore the River Yamuna.
Collapse
Affiliation(s)
- Lakhvinder Kaur
- Department of Environment Studies, Panjab University, Sector 14, Chandigarh, 160014, India.
| | - Madhuri S Rishi
- Department of Environment Studies, Panjab University, Sector 14, Chandigarh, 160014, India
| | - Naresh Kumar Arora
- Indian Council of Agricultural Research-Central Soil Salinity Research Institute, Karnal, Haryana, 132001, India
| |
Collapse
|
6
|
Tang P, Wu J, Liu H, Liu Y, Zhou X. Assimilable organic carbon (AOC) determination using GFP-tagged Pseudomonas fluorescens P-17 in water by flow cytometry. PLoS One 2018; 13:e0199193. [PMID: 29902279 PMCID: PMC6002121 DOI: 10.1371/journal.pone.0199193] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Accepted: 06/01/2018] [Indexed: 11/30/2022] Open
Abstract
One of the newly developed methods for Assimilable organic carbon (AOC) determination is leveraged on the cell enumeration by flow cytometry (FC) which could provide a rapid and automated solution for AOC measurement. However, cell samples staining with fluorescence dye is indispensable to reduce background and machine noise. This step would bring additional cost and time consuming for this method. In this study, a green fluorescence protein (GFP) tagged strain derived of AOC testing strain Pseudomonas fluorescens P-17 (GFP-P17) was generated using Tn5 transposon mutagenesis. Continuous culture of this mutant GFP-P17 showed stable expression of eGFP signal detected by flow cytometry without staining step. In addition, this GFP-P17 strain displayed faster growth rate and had a wider range of carbon substrate utilization patterns as compared with P17 wild-type. With this strain, the capability of a new FC method with no dye staining was explored in standard acetate solution, which suggests linear correlation of counts with acetate carbon concentration. Furthermore, this FC method with GFP-P17 strain is applicable in monitoring GAC/BAC efficiency and condition as similar trends of AOC level in water treatment process were measured by both FC method and conventional spread plating count method. Therefore, this fast and easily applicable GFP-P17 based FC method could serve as a tool for routine microbiological drinking water monitoring.
Collapse
Affiliation(s)
- Peng Tang
- School of Life Sciences and Chemical Technology, Ngee Ann Polytechnic, 599489, Singapore, Singapore
| | - Jie Wu
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China
| | - Hou Liu
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China
| | - Youcai Liu
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China
| | - Xingding Zhou
- School of Life Sciences and Chemical Technology, Ngee Ann Polytechnic, 599489, Singapore, Singapore
- * E-mail:
| |
Collapse
|
7
|
Liao X, Zou R, Chen C, Yuan B, Zhou Z, Zhang X. Evaluating the biosafety of conventional and O 3-BAC process and its relationship with NOM characteristics. ENVIRONMENTAL TECHNOLOGY 2018; 39:221-230. [PMID: 28274190 DOI: 10.1080/09593330.2017.1297850] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2016] [Accepted: 02/15/2017] [Indexed: 06/06/2023]
Abstract
It is the priority to guarantee biosafety for drinking water treatment. The objective of this study was to evaluate the impact of widely applied conventional and ozone-biological activated carbon (O3-BAC) advanced treatment technology on biosafety of drinking water. The items, including assimilable organic carbon (AOC), biodegradable dissolved organic carbon (BDOC), heterotrophic plate counts (HPCs) and the microorganism community structures, were used to evaluate the biosafety. Moreover, their relationships with molecular weights (MWs) and fluorescence intensity of dissolved organic matter were investigated. The results indicated that the technology provided a considerable gain in potable water quality by decreasing dissolved organic carbon (DOC, from 5.05 to 1.71 mg/L), AOC (from 298 to 131 μg/L), BDOC (from 1.39 to 0.24 mg/L) and HPCs (from 275 to 10 CFU/mL). Ozone brought an increase in DOC with low MW <1 kDa, which accompanies with an increase in AOC/BDOC concentration, which could be reduced effectively by subsequent BAC process. The formation of AOC/BDOC was closely related to DOC with low MWs and aromatic protein. Bacteria could be released from BAC filter, resulting in an increase in HPC and the presence of pathogenic bacteria in effluent, while the post sand filter could further guarantee the biosafety of finished water.
Collapse
Affiliation(s)
- Xiaobin Liao
- a Institute of Municipal and Environmental Engineering, College of Civil Engineering , Huaqiao University , Xiamen , People's Republic of China
- b State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment , Tsinghua University , Beijing , People's Republic of China
| | - Rusen Zou
- a Institute of Municipal and Environmental Engineering, College of Civil Engineering , Huaqiao University , Xiamen , People's Republic of China
| | - Chao Chen
- b State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment , Tsinghua University , Beijing , People's Republic of China
| | - Baoling Yuan
- a Institute of Municipal and Environmental Engineering, College of Civil Engineering , Huaqiao University , Xiamen , People's Republic of China
| | - Zhenming Zhou
- a Institute of Municipal and Environmental Engineering, College of Civil Engineering , Huaqiao University , Xiamen , People's Republic of China
| | - Xiaojian Zhang
- b State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment , Tsinghua University , Beijing , People's Republic of China
| |
Collapse
|
8
|
Sorlini S, Gialdini F, Collivignarelli C. Metal leaching in drinking water domestic distribution system: an Italian case study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH 2014; 24:497-514. [PMID: 24382119 DOI: 10.1080/09603123.2013.865715] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The objective of this study was to evaluate metal contamination of tap water in seven public buildings in Brescia (Italy). Two monitoring periods were performed using three different sampling methods (overnight stagnation, 30-min stagnation, and random daytime). The results show that the water parameters exceeding the international standards (Directive 98/83/EC) at the tap were lead (max = 363 μg/L), nickel (max = 184 μg/L), zinc (max = 4900 μg/L), and iron (max = 393 μg/L). Compared to the total number of tap water samples analyzed (122), the values higher than limits of Directive 98/83/EC were 17% for lead, 11% for nickel, 14% for zinc, and 7% for iron. Three buildings exceeded iron standard while five buildings exceeded the standard for nickel, lead, and zinc. Moreover, there is no evident correlation between the leaching of contaminants in the domestic distribution system and the age of the pipes while a significant influence is shown by the sampling methods.
Collapse
Affiliation(s)
- Sabrina Sorlini
- a Department of Civil Department of Civil Engineering, Architecture, Land, Environment and Mathematics , University of Brescia , Brescia , Italy
| | | | | |
Collapse
|
9
|
Lenz J, Linke S, Gemein S, Exner M, Gebel J. Verification of the efficiency of chemical disinfection and sanitation measures in in-building distribution systems. Int J Hyg Environ Health 2010; 213:198-203. [DOI: 10.1016/j.ijheh.2010.04.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2009] [Revised: 03/03/2010] [Accepted: 04/16/2010] [Indexed: 10/19/2022]
|