Ganjoo R, Sharma S, Verma C, Quraishi MA, Kumar A. Heteropolysaccharides in sustainable corrosion inhibition: 4E (Energy, Economy, Ecology, and Effectivity) dimensions. Int J Biol Macromol 2023; 235:123571. [PMID: 36750168 DOI: 10.1016/j.ijbiomac.2023.123571] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 01/24/2023] [Accepted: 02/03/2023] [Indexed: 02/07/2023]
Abstract
Carbohydrate polymers (polysaccharides) and their derivatives are widely utilized in sustainable corrosion inhibition (SCI) because of their various fascinating properties including multiple adsorption sites, high solubility and high efficiency. Contrary to traditional synthetic polymer-based corrosion inhibitors, polysaccharides are related to the 4E dimension, which stands for Energy, Economy, Ecology, and Effectivity. Furthermore, they are relatively more environmentally benign, biodegradable, and non-bioaccumulative. The current review describes the SCI features of various heteropolysaccharides, including gum Arabic (GA), glycosaminoglycans (chondroitin-4-sulfate (CS), hyaluronic acid (HA), heparin, etc.), pectin, alginates, and agar for the first time. They demonstrate impressive anticorrosive activity for different metals and alloys in a variety of corrosive electrolytes. Through their adsorption at the metal/electrolyte interface, heteropolysaccharides function by producing a corrosion-protective film. In general, their adsorption follows the Langmuir isotherm model. In their molecular structures, heteropolysaccharides contain several polar functional groups like -OH, -NH2, -COCH3, -CH2OH, cyclic and bridging O, -CH2SO3H, -SO3OH, -COOH, -NHCOCH3, -OHOR, etc. that serve as adsorption centers when they bind to metallic surfaces.
Collapse
Affiliation(s)
- Richika Ganjoo
- Department of Chemistry, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Punjab, India
| | - Shveta Sharma
- Department of Chemistry, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Punjab, India
| | - Chandrabhan Verma
- Center of Research Excellence in Corrosion, Research Institute, King Fahd University of Petroleum & Minerals, Dhahran 31261, Saudi Arabia.
| | - M A Quraishi
- Center of Research Excellence in Corrosion, Research Institute, King Fahd University of Petroleum & Minerals, Dhahran 31261, Saudi Arabia
| | - Ashish Kumar
- Department of Chemistry, School of Chemical Engineering and Physical Sciences, Lovely Professional University, Punjab, India; NCE, Department of Science and Technology, Government of Bihar, India.
| |
Collapse
|
2
|
Radice S, Neto MQ, Fischer A, Wimmer MA. Nickel-free high-nitrogen austenitic steel outperforms CoCrMo alloy regarding tribocorrosion in simulated inflammatory synovial fluids. J Orthop Res 2022; 40:1397-1408. [PMID: 34449923 PMCID: PMC8882197 DOI: 10.1002/jor.25174] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 07/13/2021] [Accepted: 08/13/2021] [Indexed: 02/04/2023]
Abstract
CoCrMo alloys are well-established biomaterials used for orthopedic joint replacement implants. However, such alloys have been associated with clinical problems related to wear and corrosion. A new generation of austenitic high-nitrogen steels (AHNSs) has been developed for biomedical applications. Here, we have addressed influences of hyaluronic acid, combined with inflammatory (oxidizing) conditions, on tribocorrosion of the high-nitrogen FeCrMnMoN0.9 steel (DIN/EN X13CrMnMoN18-14-3, 1.4452), and of the low carbon CoCrMo0.03 alloy (ISO 5832-12). We aimed to elucidate critical and clinically relevant conditions affecting the implant's performance in certain orthopedic applications. Tribocorrosion tests were conducted in triplicate, with discs under reciprocating sliding wear against a ceramic ball. Different lubricants were prepared from standardized bovine serum solution (ISO 14242-1), with variable additions of hyaluronic acid (HA) and hydrogen peroxide (H2 O2 ). Test conditions were: 37°C, 86,400 cycles, 37 N load (20-40 MPa after run-in phase). Volumetric wear was quantified; surfaces were evaluated by electrochemical parameters and microscopy/spectroscopy analyses (SEM/EDS). Factorial analysis of variance tests was conducted to examine the effects of HA, H2 O2 , and test material on wear- and corrosion-related dependent variables. Tribocorrosion performances of CoCrMo0.03 and FeCrMnMoN0.9 were comparable in fluids without H2 O2 . With higher H2 O2 concentrations, tribocorrosion increased for CoCrMo0.03 , while this was not the case for FeCrMnMoN0.9 . HA significantly enhanced wear of CoCrMo0.03 in the absence of H2 O2 , while it mitigated the tribocorrosive action of 3 mM H2 O2 ; HA had no impact on FeCrMnMoN0.9 . These results indicate a favorable performance of FeCrMnMoN0.9 compared to CoCrMo0.03 , and encourage further research on AHNS for certain orthopedic applications.
Collapse
Affiliation(s)
- Simona Radice
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison Street, Chicago, IL 60612, USA
| | - Mozart Q. Neto
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison Street, Chicago, IL 60612, USA
| | - Alfons Fischer
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison Street, Chicago, IL 60612, USA
| | - Markus A. Wimmer
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison Street, Chicago, IL 60612, USA
| |
Collapse
|
3
|
The Electrochemical Behavior of Ti in Human Synovial Fluids. MATERIALS 2022; 15:ma15051726. [PMID: 35268957 PMCID: PMC8910938 DOI: 10.3390/ma15051726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 02/21/2022] [Accepted: 02/23/2022] [Indexed: 11/18/2022]
Abstract
In this study, we report results of the interaction of titanium (Ti) with human synovial fluids. A wide palette of electrochemical techniques was used, including open circuit potential, potentiodynamic methods, and electrochemical impedance. After the electrochemical testing, selected surfaces were analyzed using Auger Electron Spectroscopy to provide laterally resolved information on surface chemistry. For comparison purposes, similar tests were conducted in a series of simulated body fluids. This study shows that compared to the tested simulated body fluids, synovial liquids show a large patient variability up to one order of magnitude for some crucial electrochemical parameters such as corrosion current density. The electrochemical behavior of Ti exposed to human synovial fluids seems to be controlled by the interaction with organic molecules rather than with reactive oxygen species.
Collapse
|
4
|
Radice S, Tibbits G, Lin AYW, Beyenal H, Wimmer MA. Interactions between hyaluronic acid and CoCrMo alloy surface in simulated synovial fluids. BIOSURFACE AND BIOTRIBOLOGY 2021. [DOI: 10.1049/bsb2.12027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Affiliation(s)
- Simona Radice
- Department of Orthopedic Surgery Rush University Medical Center Chicago Illinois USA
| | - Gretchen Tibbits
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering Washington State University Pullman Washington USA
| | - Alex Y. W. Lin
- Department of Materials Science and Engineering Northwestern University Evanston llinois USA
| | - Haluk Beyenal
- The Gene and Linda Voiland School of Chemical Engineering and Bioengineering Washington State University Pullman Washington USA
| | - Markus A. Wimmer
- Department of Orthopedic Surgery Rush University Medical Center Chicago Illinois USA
| |
Collapse
|
5
|
Sikkema R, Keohan B, Zhitomirsky I. Hyaluronic-Acid-Based Organic-Inorganic Composites for Biomedical Applications. MATERIALS (BASEL, SWITZERLAND) 2021; 14:4982. [PMID: 34501070 PMCID: PMC8434239 DOI: 10.3390/ma14174982] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 08/23/2021] [Accepted: 08/27/2021] [Indexed: 01/22/2023]
Abstract
Applications of natural hyaluronic acid (HYH) for the fabrication of organic-inorganic composites for biomedical applications are described. Such composites combine unique functional properties of HYH with functional properties of hydroxyapatite, various bioceramics, bioglass, biocements, metal nanoparticles, and quantum dots. Functional properties of advanced composite gels, scaffold materials, cements, particles, films, and coatings are described. Benefiting from the synergy of properties of HYH and inorganic components, advanced composites provide a platform for the development of new drug delivery materials. Many advanced properties of composites are attributed to the ability of HYH to promote biomineralization. Properties of HYH are a key factor for the development of colloidal and electrochemical methods for the fabrication of films and protective coatings for surface modification of biomedical implants and the development of advanced biosensors. Overcoming limitations of traditional materials, HYH is used as a biocompatible capping, dispersing, and structure-directing agent for the synthesis of functional inorganic materials and composites. Gel-forming properties of HYH enable a facile and straightforward approach to the fabrication of antimicrobial materials in different forms. Of particular interest are applications of HYH for the fabrication of biosensors. This review summarizes manufacturing strategies and mechanisms and outlines future trends in the development of functional biocomposites.
Collapse
Affiliation(s)
| | | | - Igor Zhitomirsky
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON L8S4L7, Canada; (R.S.); (B.K.)
| |
Collapse
|
6
|
Radice S, Impergre A, Fischer A, Wimmer MA. Corrosion resistance of the nickel-free high-nitrogen steel FeCrMnMoN0.9 under simulated inflammatory conditions. J Biomed Mater Res B Appl Biomater 2020; 109:902-910. [PMID: 33159504 DOI: 10.1002/jbm.b.34754] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 09/03/2020] [Accepted: 10/21/2020] [Indexed: 11/09/2022]
Abstract
Nickel-free, high-nitrogen austenitic steels (AHNS) have been introduced for biomedical applications, with encouraging results in terms of mechanical and corrosion properties. Here, we tested the corrosion resistance of a nickel-free high nitrogen steel (FeCrMnMoN0.9) in bovine serum solutions containing 0 or 3 g/L hyaluronic acid (HA), and 0, 3, or 30 mM hydrogen peroxide (H2 O2 ) simulating no, moderate, or strong inflammatory conditions, respectively. Nondestructive electrochemical measurements (open circuit potential [OCP], linear polarization resistance "RP ", and electrochemical impedance spectroscopy) were run in triplicate over 10 hr. The presence of HA had no significant effect either on the stabilized OCP values, or on the corrosion resistance of FeCrMnMoN0.9. Increasing H2 O2 concentrations shifted the OCP to more electropositive values; the corrosion resistance decreased only at a 30 mM H2 O2 . Final RP values at 0, 3, and 30 mM H2 O2 resulted in 1598 ± 276, 1746 ± 308, and 439 ± 47 kΩ cm2 , respectively. These values were 4-14 times higher, than the RP values measured on LC-CoCrMo in our previous study, conducted under identical conditions. While these findings are encouraging, future studies need to focus on tribocorrosive properties of the AHNS to evaluate its applicability in joint replacement.
Collapse
Affiliation(s)
- Simona Radice
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Amandine Impergre
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Alfons Fischer
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Markus A Wimmer
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois, USA
| |
Collapse
|
7
|
Wiegand MJ, Khullar P, Mercuri JJ, Gilbert JL. Synthetic periprosthetic synovial fluid development for in vitro cell-tribocorrosion testing using the Taguchi array approach. J Biomed Mater Res A 2020; 109:551-561. [PMID: 32946189 DOI: 10.1002/jbm.a.37039] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 06/04/2020] [Accepted: 06/09/2020] [Indexed: 12/26/2022]
Abstract
Synovial fluid is dynamic in vivo with biological components changing in ratio and size depending on the health of the joint space, making it difficult to model in vitro. Previous efforts to develop synthetic synovial fluid have typically focused on single organic-tribological interactions with implant surfaces, thus ignoring interplay between multiple solution components. Using a Taguchi orthogonal array, we were able to isolate the individual effects of five independent synovial fluid composition variables: ratios of (1) hyaluronic acid to phospholipids (HA:PL) and (2) albumin to globulin (A:G), and concentrations of (3) hydrogen peroxide (H2 O2 ), (4) cobalt (Co2+ ) and (5) chromium (Cr3+ ) ions on macrophage viability and reduced glutathione production, local solution pH and the comprehensive CoCrMo alloy electrochemical response. While no single synovial fluid variable significantly affected the collective response, HA:PL ratio resulted in the largest impact factor (Δ) on 12 of the 13 measured responses with significant effects (p < .05) on the average macrophage survival rate and electrochemical capacitive state of the CoCrMo surface. Cluster analysis separated significant responses from all trials into three groups, corresponding to healthy, mild, or severely inflamed fluids, respectively; with the healthy synovial fluid composition having mid-range HA:PL ratios with no Co2+ ions, and the severely inflamed fluids consisting of low and high HA:PL ratios with H2 O2 and Co2+ ions. By utilizing the Taguchi approach in combination with cluster analysis, we were able to advance our knowledge of complex multivariate synthetic synovial fluids influence on macrophage and electrochemical behavior at the cell-solution-metal interface.
Collapse
Affiliation(s)
- Michael J Wiegand
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA.,The Clemson University-Medical University of South Carolina Program in Bioengineering, Clemson University, Charleston, South Carolina, USA
| | - Piyush Khullar
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA.,The Clemson University-Medical University of South Carolina Program in Bioengineering, Clemson University, Charleston, South Carolina, USA
| | - Jeremy J Mercuri
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
| | - Jeremy L Gilbert
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA.,The Clemson University-Medical University of South Carolina Program in Bioengineering, Clemson University, Charleston, South Carolina, USA
| |
Collapse
|
8
|
Effects of bovine serum albumin and hyaluronic acid on the electrochemical response of a CoCrMo alloy to cathodic and anodic excursions. ACTA ACUST UNITED AC 2019; 5. [PMID: 31828005 DOI: 10.1007/s40735-019-0299-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The problem of wear and corrosion of CoCrMo-implant surfaces in the human body following total joint replacement has been commonly investigated with tribocorrosion tests, using different lubricants meant to simulate the pseudo-synovial fluid. While results considering the synovial fluid components separately have highlighted their individual influence on the tribological performance of CoCrMo-alloy, an understanding about the influence of the synovial fluid components under the electrochemical point of view is missing. This work aims to investigate the effect of bovine serum albumin (BSA) and hyaluronic acid (HA) on electrochemical potential variations of CoCrMo alloys tested in a model synovial fluid. To simulate the environment inside the synovial capsule, the tests were performed inside a CO2 incubator at 37°C. Open circuit potential, electrochemical impedance spectroscopy, cathodic and anodic potentiodynamic measurements were performed with different electrolytes, prepared with cell culture medium (RMPI-1640), BSA and HA. The final CoCrMo-surface was analyzed by SEM/EDS and infrared spectroscopy. The influence of HA on the corrosion of the CoCrMo-alloy depended on the presence of BSA proteins adsorbed on the CoCrMo-surface: EIS and anodic polarization results showed a corrosive action of HA in the absence of adsorbed proteins. In the presence of both BSA and HA, organometallic precipitates were found on the CoCrMo surface following reverse anodic polarization, which remind of corrosion products found in-vivo. These results indicate that HA affects the interaction of CoCrMo implant alloys with protein-containing model synovial fluids, and suggest that HA needs to be considered in tribocorrosion studies for more clinically relevant outcomes.
Collapse
|
9
|
Radice S, Yao J, Babauta J, Laurent MP, Wimmer MA. The effect of hyaluronic acid on the corrosion of an orthopedic CoCrMo-alloy in simulated inflammatory conditions. MATERIALIA 2019; 6:100348. [PMID: 31183460 PMCID: PMC6554727 DOI: 10.1016/j.mtla.2019.100348] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
During joint inflammation, various reactive oxygen species (ROS) are present in the surrounding tissue and joint fluid. In the laboratory, hydrogen peroxide (H2O2) is typically used to simulate inflammatory conditions, and media containing proteins and hyaluronic acid (HA) are employed to simulate joint synovial fluid. Electrochemical interactions between H2O2 and HA in the presence of a CoCrMo surface are expected, since HA molecules contain redox-active moieties. We hypothesized that any redox reactions of these moieties with ROS will mitigate the oxidizing effect of H2O2 on the CoCrMo surface, limiting the corrosion rate of the metal. Non-destructive electrochemical measurements (open circuit potential, linear polarization resistance and electrochemical impedance spectroscopy) were used to investigate the corrosion response of CoCrMo in synovial model fluid containing physiologically relevant concentrations of albumin proteins and hyaluronic acid, with and without H2O2. Two different molarities of H2O2, 3 mM and 30 mM, were tested. While both molarities are within physiological limits, 3mM is well within the range HA could mitigate, whereas 30 mM is not. Contrary to our hypothesis, HA did not alleviate corrosion in 3 mM H2O2 and even caused a corrosion increase in the case of 30 mM H2O2. The decrease in corrosion resistance of the alloy may be attributed to the complexation of degenerated HA molecular chains with chromium ions released from the metallic surface, which are necessary to build a protective oxide film. This finding has clinical implications, suggesting that HA accelerates corrosion of CoCrMo implants in the presence of strong inflammation.
Collapse
Affiliation(s)
- S Radice
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison Street, Chicago, IL 60612, USA
| | - J Yao
- University of Washington, Department of Orthopaedic Surgery and Sports Medicine, 401 Broadway, Seattle, WA 98122, USA
| | - J Babauta
- Washington State University, The Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Wegner Hall, PO Box 646515, Pullman, WA 99164-6515, USA
| | - M P Laurent
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison Street, Chicago, IL 60612, USA
| | - M A Wimmer
- Rush University Medical Center, Department of Orthopedic Surgery, 1611 W. Harrison Street, Chicago, IL 60612, USA
| |
Collapse
|
10
|
Diaz I, Martinez-Lerma JF, Montoya R, Llorente I, Escudero ML, García-Alonso MC. Study of overall and local electrochemical responses of oxide films grown on CoCr alloy under biological environments. Bioelectrochemistry 2017; 115:1-10. [PMID: 28126645 DOI: 10.1016/j.bioelechem.2017.01.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Revised: 01/16/2017] [Accepted: 01/16/2017] [Indexed: 11/25/2022]
Abstract
The interaction of the physiological medium and living tissues with the implant surfaces in biological environments is regulated by biopotentials that induce changes in the chemical composition, structure and thickness of the oxide film. In this work, oxide films grown on CoCr alloys at 0.5 V vs Ag/AgCl and 0.7 V vs Ag/AgCl have been characterized through overall and localized electrochemical techniques in a phosphate buffer solution and 0.3% hyaluronic acid. Nanopores of 10-50nm diameter are homogeneously distributed along the surface in the oxide film formed at 0.7 V vs Ag/AgCl. The distribution of the Constant Phase Element studied by local electrochemical impedance spectroscopy showed a three-dimensional (3D) model on the oxide films grown at 0.5 V vs Ag/AgCl and 0.7 V vs Ag/AgCl. This behaviour is especially noticeable in oxide films grown at 0.7 V vs Ag/AgCl, probably due to surface inhomogeneities, and resistive properties generated by the potentiostatic growth of the oxide film.
Collapse
Affiliation(s)
- I Diaz
- Centro Nacional de Investigaciones Metalúrgicas (CENIM), Consejo Superior de Investigaciones Científicas (CSIC), Avenida Gregorio del Amo, 8, Madrid, Spain
| | - J F Martinez-Lerma
- Facultad de Ciencias Químicas, Universidad Autónoma de San Luís Potosí, S.L.P. Av. Dr. Manuel Nava No. 6, Zona Universitaria, C.P. 78210 San Luis Potosí, S.L.P., Mexico
| | - R Montoya
- Centro Nacional de Investigaciones Metalúrgicas (CENIM), Consejo Superior de Investigaciones Científicas (CSIC), Avenida Gregorio del Amo, 8, Madrid, Spain; Research Group Electrochemical and Surface Engineering, Vrije Universiteit Brussel, Campus Etterbeek Pleinlaan 2, 1050 Brussels, Belgium
| | - I Llorente
- Centro Nacional de Investigaciones Metalúrgicas (CENIM), Consejo Superior de Investigaciones Científicas (CSIC), Avenida Gregorio del Amo, 8, Madrid, Spain
| | - M L Escudero
- Centro Nacional de Investigaciones Metalúrgicas (CENIM), Consejo Superior de Investigaciones Científicas (CSIC), Avenida Gregorio del Amo, 8, Madrid, Spain
| | - M C García-Alonso
- Centro Nacional de Investigaciones Metalúrgicas (CENIM), Consejo Superior de Investigaciones Científicas (CSIC), Avenida Gregorio del Amo, 8, Madrid, Spain.
| |
Collapse
|
11
|
In vivo electrochemical corrosion study of a CoCrMo biomedical alloy in human synovial fluids. Acta Biomater 2015; 21:228-36. [PMID: 25797841 DOI: 10.1016/j.actbio.2015.03.008] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2014] [Revised: 02/09/2015] [Accepted: 03/05/2015] [Indexed: 11/22/2022]
Abstract
The present study was initiated with the aim to assess the in vivo electrochemical corrosion behaviour of CoCrMo biomedical alloys in human synovial fluids in an attempt to identify possible patient or pathology specific effects. For this, electrochemical measurements (open circuit potential OCP, polarization resistance Rp, potentiodynamic polarization curves, electrochemical impedance spectroscopy EIS) were carried out on fluids extracted from patients with different articular pathologies and prosthesis revisions. Those electrochemical measurements could be carried out with outstanding precision and signal stability. The results show that the corrosion behaviour of CoCrMo alloy in synovial fluids not only depends on material reactivity but also on the specific reactions of synovial fluid components, most likely involving reactive oxygen species. In some patients the latter were found to determine the whole cathodic and anodic electrochemical response. Depending on patients, corrosion rates varied significantly between 50 and 750 mg dm(-2)year(-1).
Collapse
|
12
|
Tas AC. The use of physiological solutions or media in calcium phosphate synthesis and processing. Acta Biomater 2014; 10:1771-92. [PMID: 24389317 DOI: 10.1016/j.actbio.2013.12.047] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2013] [Revised: 12/02/2013] [Accepted: 12/17/2013] [Indexed: 11/29/2022]
Abstract
This review examined the literature to spot uses, if any, of physiological solutions/media for the in situ synthesis of calcium phosphates (CaP) under processing conditions (i.e. temperature, pH, concentration of inorganic ions present in media) mimicking those prevalent in the human hard tissue environments. There happens to be a variety of aqueous solutions or media developed for different purposes; sometimes they have been named as physiological saline, isotonic solution, cell culture solution, metastable CaP solution, supersaturated calcification solution, simulated body fluid or even dialysate solution (for dialysis patients). Most of the time such solutions were not used as the aqueous medium to perform the biomimetic synthesis of calcium phosphates, and their use was usually limited to the in vitro testing of synthetic biomaterials. This review illustrates that only a limited number of research studies used physiological solutions or media such as Earle's balanced salt solution, Bachra et al. solutions or Tris-buffered simulated body fluid solution containing 27mM HCO3(-) for synthesizing CaP, and these studies have consistently reported the formation of X-ray-amorphous CaP nanopowders instead of Ap-CaP or stoichiometric hydroxyapatite (HA, Ca10(PO4)6(OH)2) at 37°C and pH 7.4. By relying on the published articles, this review highlights the significance of the use of aqueous solutions containing 0.8-1.5 mMMg(2+), 22-27mM HCO3(-), 142-145mM Na(+), 5-5.8mM K(+), 103-133mM Cl(-), 1.8-3.75mM Ca(2+), and 0.8-1.67mM HPO4(2-), which essentially mimic the composition and the overall ionic strength of the human extracellular fluid (ECF), in forming the nanospheres of X-ray-amorphous CaP.
Collapse
Affiliation(s)
- A Cuneyt Tas
- Department of Materials Science and Engineering, University of Illinois, Urbana, IL 61801, USA.
| |
Collapse
|