Huang W, Mok GSP. Multi-pinhole collimator design in different numbers of projections for brain SPECT. Front Med (Lausanne) 2023; 10:1211726. [PMID: 37841005 PMCID: PMC10568733 DOI: 10.3389/fmed.2023.1211726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 08/31/2023] [Indexed: 10/17/2023] Open
Abstract
Purpose High resolution and sensitivity brain SPECT is promising for the accurate diagnosis of Alzheimer's disease (AD) and Parkinson's disease (PD). Multi-pinhole (MPH) collimators with a good performance in imaging small field-of-view (FOV) could be better used for brain SPECT. In this study, we aim to evaluate the impact of varying the number of pinholes and the number of projections on the performance of MPH brain SPECT. Methods The system design was based on a commercial clinical dual-head SPECT/CT scanner, with target spatial resolutions of 12 mm and 8 mm for AD and PD SPECT, respectively. In total, 1-25 pinholes were modeled for 64, 32, 16, 8, 4, and 2 projections. The 3D NURBS-based HUman Brain (NHUB) phantom was used in the analytical simulation to model 99mTc-HMPAO and 99mTc-TRODAT distributions. The 2D Derenzo hot-rod phantom and star phantom were used in Monte Carlo simulations to evaluate the spatial resolution and angular sampling performance of MPH. The influence of different detector positions was also evaluated for 2, 4, and 6 angular views. The projections were reconstructed using the 3D MPH ML-EM method. Normalized mean square error, coefficient of variation, and image profiles were evaluated. Results Along with the decrease in the number of projections, more pinholes are required to achieve the optimum performance. For 32 projections, 9- and 7-pinhole collimators provide the best normalized mean square error (NMSE) to the coefficient of variation (COV) trade-off for 99mTc-HMPAO and 99mTc-TRODAT, respectively. Detector positions substantially affect the image quality for MPH SPECT for 2 and 4 angular views. The smallest rod size for the Derenzo hot-rod phantom, which could be resolved, is 7.9 mm for the MPH general purpose collimator (MPGP) with more than 16 projections and 6.4 mm for MPH high-resolution collimator (MPHR) with more than 8 projections. Conclusion The number of pinholes affects the performance of the MPH collimator, especially when the projection views become fewer. More pinholes are required for fewer projections to provide better angular sampling in MPH for complex activity distributions. Detector positions affect the image quality of MPH SPECT for 2 and 4 angular views, where L-mode acquisition is slightly superior to H-mode. MPH collimators exhibited improved spatial resolution and angular sampling compared with both LEHR and single pinhole collimators.
Collapse
Affiliation(s)
- Wenbo Huang
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
| | - Greta S. P. Mok
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
- Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macau SAR, China
| |
Collapse
|
2
|
Zhang D, Lyu Z, Liu Y, He ZX, Yao R, Ma T. Characterization and Assessment of Projection Probability Density Function and Enhanced Sampling in Self-Collimation SPECT. IEEE TRANSACTIONS ON MEDICAL IMAGING 2023; 42:2787-2801. [PMID: 37037258 PMCID: PMC10597595 DOI: 10.1109/tmi.2023.3265874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
We have recently reported a self-collimation SPECT (SC-SPECT) design concept that constructs sensitive detectors in a multi-ring interspaced mosaic architecture to simultaneously improve system spatial resolution and sensitivity. In this work, through numerical and Monte-Carlo simulation studies, we investigate this new design concept by analyzing its projection probability density functions (PPDF) and the effects of enhanced sampling, i.e. having rotational and translational object movements during imaging. We first quantitatively characterize PPDFs by their widths and edge slopes. Then we compare the PPDFs of an SC-SPECT and a series of multiple-pinhole SPECT (MPH-SPECT) systems and assess the impact of PPDFs - combined with enhanced sampling - on image contrast recovery coefficient and variance through phantom studies. We show the PPDFs of SC- SPECT have steeper edges and a wider range of width, and these attributes enable SC-SPECT to achieve better performance.
Collapse
|
3
|
Ozsahin I, Chen L, Könik A, King MA, Beekman FJ, Mok GSP. The clinical utilities of multi-pinhole single photon emission computed tomography. Quant Imaging Med Surg 2020; 10:2006-2029. [PMID: 33014732 PMCID: PMC7495312 DOI: 10.21037/qims-19-1036] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 07/30/2020] [Indexed: 11/06/2022]
Abstract
Single photon emission computed tomography (SPECT) is an important imaging modality for various applications in nuclear medicine. The use of multi-pinhole (MPH) collimators can provide superior resolution-sensitivity trade-off when imaging small field-of-view compared to conventional parallel-hole and fan-beam collimators. Besides the very successful application in small animal imaging, there has been a resurgence of the use of MPH collimators for clinical cardiac and brain studies, as well as other small field-of-view applications. This article reviews the basic principles of MPH collimators and introduces currently available and proposed clinical MPH SPECT systems.
Collapse
Affiliation(s)
- Ilker Ozsahin
- Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau, China
- Department of Biomedical Engineering, Faculty of Engineering, Near East University, Nicosia/TRNC, Mersin-10, Turkey
- DESAM Institute, Near East University, Nicosia/TRNC, Mersin-10, Turkey
| | - Ling Chen
- Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau, China
| | - Arda Könik
- Department of Imaging, Dana Farber Cancer Institute, Boston, MA, USA
| | - Michael A. King
- Department of Radiology, University of Massachusetts Medical School, Worcester, MA, USA
| | - Freek J. Beekman
- Section of Biomedical Imaging, Department of Radiation Science and Technology, Delft University of Technology, Mekelweg 15, 2629 JB Delft, The Netherlands
- MILabs B.V, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
- Department of Translational Neuroscience, Brain Center Rudolf Magnus, University Medical Center Utrecht, The Netherlands
| | - Greta S. P. Mok
- Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau, China
- Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Macau, China
| |
Collapse
|
4
|
Wang H, Nie K, Kuang Y. An On-Board Spectral-CT/CBCT/SPECT Imaging Configuration for Small-Animal Radiation Therapy Platform: A Monte Carlo Study. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:588-600. [PMID: 31380751 DOI: 10.1109/tmi.2019.2932333] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This study investigated the feasibility of a highly specific multiplexed image-guided small animal radiation therapy (SART) platform based on triple imaging from on-board single-photon emission computed tomography (SPECT), spectral-CT, and cone-beam CT (CBCT) guidance in radiotherapy treatment. As a proof-of-concept, the SART system was built with the capability of triple on-board image guidance by utilizing an x-ray tube and a single cadmium zinc telluride (CZT) semiconductor photon-counting imager via a Monte Carlo simulation study. The x-ray tube can be set at a low tube current for imaging mode and a high tube current for radiation therapy mode, respectively. In the imaging mode, both x-ray and gamma-ray projection data were collected by the imager to reconstruct CBCT, SPECT and spectral CT images of small animals being treated. The modulation transfer function (MTF) of the pixelated CZT imager measured was 8.6 lp/mm. The overall performances of the CBCT and SPECT imaging of the system were evaluated with sufficient spatial resolution and imaging quality to be fitted into the SART platform. The material differentiation and decomposition capacities of spectral CT within the system were verified using K-edge imaging, image-based optimal energy weighted imaging, and image-based linear material decomposition methods. The triple imaging capability of the system was demonstrated using a PMMA phantom containing gadolinium, iodine and radioisotope 99mTc inserts. All the probes were clearly identified in the registered image. The results demonstrated that a novel SART platform with high-quality on-board CBCT, spectral-CT, SPECT image guidance is technically feasible by using a single semiconductor imager, thus affording comprehensive image guidance from anatomical, functional, and molecular levels for radiation treatment beam delivery.
Collapse
|
5
|
Lin A, Kupinski MA, Peterson TE, Shokouhi S, Johnson LC. Task-based design of a synthetic-collimator SPECT system used for small animal imaging. Med Phys 2018; 45:2952-2963. [PMID: 29734479 DOI: 10.1002/mp.12952] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2017] [Revised: 02/12/2018] [Accepted: 02/25/2018] [Indexed: 11/08/2022] Open
Abstract
PURPOSE In traditional multipinhole SPECT systems, image multiplexing - the overlapping of pinhole projection images - may occur on the detector, which can inhibit quality image reconstructions due to photon-origin uncertainty. One proposed system to mitigate the effects of multiplexing is the synthetic-collimator SPECT system. In this system, two detectors, a silicon detector and a germanium detector, are placed at different distances behind the multipinhole aperture, allowing for image detection to occur at different magnifications and photon energies, resulting in higher overall sensitivity while maintaining high resolution. The unwanted effects of multiplexing are reduced by utilizing the additional data collected from the front silicon detector. However, determining optimal system configurations for a given imaging task requires efficient parsing of the complex parameter space, to understand how pinhole spacings and the two detector distances influence system performance. METHODS In our simulation studies, we use the ensemble mean-squared error of the Wiener estimator (EMSEW ) as the figure of merit to determine optimum system parameters for the task of estimating the uptake of an 123 I-labeled radiotracer in three different regions of a computer-generated mouse brain phantom. The segmented phantom map is constructed by using data from the MRM NeAt database and allows for the reduction in dimensionality of the system matrix which improves the computational efficiency of scanning the system's parameter space. To contextualize our results, the Wiener estimator is also compared against a region of interest estimator using maximum-likelihood reconstructed data. RESULTS Our results show that the synthetic-collimator SPECT system outperforms traditional multipinhole SPECT systems in this estimation task. We also find that image multiplexing plays an important role in the system design of the synthetic-collimator SPECT system, with optimal germanium detector distances occurring at maxima in the derivative of the percent multiplexing function. Furthermore, we report that improved task performance can be achieved by using an adaptive system design in which the germanium detector distance may vary with projection angle. Finally, in our comparative study, we find that the Wiener estimator outperforms the conventional region of interest estimator. CONCLUSIONS Our work demonstrates how this optimization method has the potential to quickly and efficiently explore vast parameter spaces, providing insight into the behavior of competing factors, which are otherwise very difficult to calculate and study using other existing means.
Collapse
Affiliation(s)
- Alexander Lin
- College of Optical Sciences, University of Arizona, 1630 E. University Ave, Tucson, AZ, USA
| | - Matthew A Kupinski
- College of Optical Sciences, University of Arizona, 1630 E. University Ave, Tucson, AZ, USA
| | - Todd E Peterson
- Department of Radiology and Radiological Sciences, Institute of Imaging Science, Vanderbilt University Medical Center, 1161 21st Avenue South, Nashville, TN, USA
| | - Sepideh Shokouhi
- Department of Radiology and Radiological Sciences, Institute of Imaging Science, Vanderbilt University Medical Center, 1161 21st Avenue South, Nashville, TN, USA
| | - Lindsay C Johnson
- Department of Radiology, University of Pennsylvania, 3620 Hamilton Walk, Philadelphia, PA, USA
| |
Collapse
|
6
|
Chen L, Tsui BMW, Mok GSP. Design and evaluation of two multi-pinhole collimators for brain SPECT. Ann Nucl Med 2017; 31:636-648. [DOI: 10.1007/s12149-017-1195-y] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2017] [Accepted: 07/07/2017] [Indexed: 11/29/2022]
|
7
|
Xie T, Zaidi H. Development of computational small animal models and their applications in preclinical imaging and therapy research. Med Phys 2016; 43:111. [PMID: 26745904 DOI: 10.1118/1.4937598] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.
Collapse
Affiliation(s)
- Tianwu Xie
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211, Switzerland
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211, Switzerland; Geneva Neuroscience Center, Geneva University, Geneva CH-1205, Switzerland; and Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen 9700 RB, The Netherlands
| |
Collapse
|
8
|
Si C, Mok GSP, Chen L, Tsui BMW. Design and evaluation of an adaptive multipinhole collimator for high-performance clinical and preclinical imaging. Nucl Med Commun 2015; 37:313-21. [PMID: 26528787 DOI: 10.1097/mnm.0000000000000429] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE Pinhole single-photon emission computed tomography provides superior trade-off between resolution and detection efficiency as compared with conventional parallel-hole collimators for imaging small objects. This study aims to design and evaluate an optimized adaptive multipinhole (MPH) collimator for improved clinical myocardial perfusion single-photon emission computed tomography imaging (MPI) and preclinical small-animal imaging (SAI) of rats based on a clinical scanner. METHODS The target resolution and field of view was set to be 1/20 cm for MPI and 0.15/5 cm for SAI, respectively. We determined the design parameters by maximizing the detection efficiency based on system constraints. Point source simulations using Geant4 Application for Emission Tomography were performed for different collimator-to-center of field of view distances to assess the detection efficiency and resolution trade-off. The XCAT phantom with Tc-99m sestamibi distribution and the four-dimensional mouse whole-body phantom with Tc-99m methylene diphosphonate distribution were used to generate noise-free and noisy projections using a three-dimensional analytical MPH projector. Projections were reconstructed using a three-dimensional MPH ordered-subset expectation maximization algorithm. Noise and bias were assessed on the reconstructed images for different collimators. RESULTS The design parameters are (i) 14 pinholes with 3.42 mm aperture size, 14.5 cm collimator-to-detector distance for MPI; (ii) six pinholes with an aperture size of 0.94 mm, 21.2 cm collimator-to-detector distance for SAI. For MPI, the projected full width at half maximum values were 10.68 and 8.19 mm for low energy high resolution (LEHR) and MPH, respectively, whereas MPH had double detection efficiency. For SAI, the projected full width at half maximum values for LEHR and MPH were 4.93 and 1.20 mm, respectively, whereas the detection efficiency of MPH showed 17.5% improvement as compared with LEHR. The noise-bias trade-off improved for MPH as compared with LEHR for both MPI and SAI. The proposed collimator will have adjustable collimator-to-detector distances - that is, 14.5 cm for MPI and 21.2 cm for SAI. CONCLUSION The new collimator yields substantial improvement in image quality as compared with current MPI using LEHR with extra capability for SAI, bridging the clinical and preclinical imaging based on the same platform.
Collapse
Affiliation(s)
- Chinhong Si
- aBiomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China bThe Russell H. Morgan Department of Radiology and Radiological Science, Division of Medical Imaging Physics, Johns Hopkins University, Baltimore, Maryland, USA
| | | | | | | |
Collapse
|
9
|
Van Audenhaege K, Van Holen R, Vandenberghe S, Vanhove C, Metzler SD, Moore SC. Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging. Med Phys 2015; 42:4796-813. [PMID: 26233207 PMCID: PMC5148182 DOI: 10.1118/1.4927061] [Citation(s) in RCA: 81] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Revised: 07/07/2015] [Accepted: 07/08/2015] [Indexed: 01/23/2023] Open
Abstract
In single photon emission computed tomography, the choice of the collimator has a major impact on the sensitivity and resolution of the system. Traditional parallel-hole and fan-beam collimators used in clinical practice, for example, have a relatively poor sensitivity and subcentimeter spatial resolution, while in small-animal imaging, pinhole collimators are used to obtain submillimeter resolution and multiple pinholes are often combined to increase sensitivity. This paper reviews methods for production, sensitivity maximization, and task-based optimization of collimation for both clinical and preclinical imaging applications. New opportunities for improved collimation are now arising primarily because of (i) new collimator-production techniques and (ii) detectors with improved intrinsic spatial resolution that have recently become available. These new technologies are expected to impact the design of collimators in the future. The authors also discuss concepts like septal penetration, high-resolution applications, multiplexing, sampling completeness, and adaptive systems, and the authors conclude with an example of an optimization study for a parallel-hole, fan-beam, cone-beam, and multiple-pinhole collimator for different applications.
Collapse
Affiliation(s)
- Karen Van Audenhaege
- Department of Electronics and Information Systems, MEDISIP-IBiTech, Ghent University-iMinds Medical IT, De Pintelaan 185 block B/5, Ghent B-9000, Belgium
| | - Roel Van Holen
- Department of Electronics and Information Systems, MEDISIP-IBiTech, Ghent University-iMinds Medical IT, De Pintelaan 185 block B/5, Ghent B-9000, Belgium
| | - Stefaan Vandenberghe
- Department of Electronics and Information Systems, MEDISIP-IBiTech, Ghent University-iMinds Medical IT, De Pintelaan 185 block B/5, Ghent B-9000, Belgium
| | - Christian Vanhove
- Department of Electronics and Information Systems, MEDISIP-IBiTech, Ghent University-iMinds Medical IT, De Pintelaan 185 block B/5, Ghent B-9000, Belgium
| | - Scott D Metzler
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104
| | - Stephen C Moore
- Division of Nuclear Medicine, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115
| |
Collapse
|
10
|
Islamian JP, Azazrm A, Mahmoudian B, Gharapapagh E. Advances in pinhole and multi-pinhole collimators for single photon emission computed tomography imaging. World J Nucl Med 2015; 14:3-9. [PMID: 25709537 PMCID: PMC4337004 DOI: 10.4103/1450-1147.150505] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
The collimator in single photon emission computed tomography (SPECT), is an important part of the imaging chain. One of the most important collimators that used in research, preclinical study, small animal, and organ imaging is the pinhole collimator. Pinhole collimator can improve the tradeoff between sensitivity and resolution in comparison with conventional parallel-hole collimator and facilities diagnosis. However, a major problem with pinhole collimator is a small field of view (FOV). Multi-pinhole collimator has been investigated in order to increase the sensitivity and FOV with a preserved spatial resolution. The geometry of pinhole and multi-pinhole collimators is a critical factor in the image quality and plays a key role in SPECT imaging. The issue of the material and geometry for pinhole and multi-pinhole collimators have been a controversial and much disputed subject within the field of SPECT imaging. On the other hand, recent developments in collimator optimization have heightened the need for appropriate reconstruction algorithms for pinhole SPECT imaging. Therefore, iterative reconstruction algorithms were introduced to minimize the undesirable effect on image quality. Current researches have focused on geometry and configuration of pinhole and multi-pinhole collimation rather than reconstruction algorithm. The lofthole and multi-lofthole collimator are samples of novel designs. The purpose of this paper is to provide a review on recent researches in the pinhole and multi-pinhole collimators for SPECT imaging.
Collapse
Affiliation(s)
- Jalil Pirayesh Islamian
- Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | - AhmadReza Azazrm
- Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Babak Mahmoudian
- Department of Radiology, Faculty of Medicine, Unit of Nuclear Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Esmail Gharapapagh
- Department of Radiology, Faculty of Medicine, Unit of Nuclear Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
11
|
Durko HL, Barrett HH, Furenlid LR. High-Resolution Anamorphic SPECT Imaging. IEEE TRANSACTIONS ON NUCLEAR SCIENCE 2014; 61:1126-1135. [PMID: 26160983 PMCID: PMC4494124 DOI: 10.1109/tns.2014.2304853] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We have developed a gamma-ray imaging system that combines a high-resolution silicon detector with two sets of movable, half-keel-edged copper-tungsten blades configured as crossed slits. These apertures can be positioned independently between the object and detector, producing an anamorphic image in which the axial and transaxial magnifications are not constrained to be equal. The detector is a 60 mm × 60 mm, one-millimeter-thick, one-megapixel silicon double-sided strip detector with a strip pitch of 59 μm. The flexible nature of this system allows the application of adaptive imaging techniques. We present system details; calibration, acquisition, and reconstruction methods; and imaging results.
Collapse
|
12
|
Deleye S, Van Holen R, Verhaeghe J, Vandenberghe S, Stroobants S, Staelens S. Performance evaluation of small-animal multipinhole μSPECT scanners for mouse imaging. Eur J Nucl Med Mol Imaging 2013; 40:744-58. [PMID: 23344137 DOI: 10.1007/s00259-012-2326-2] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2012] [Accepted: 12/12/2012] [Indexed: 01/13/2023]
Abstract
PURPOSE We compared the performance of three commercial small-animal μSPECT scanners equipped with multipinhole general purpose (GP) and multipinhole high-resolution (HR) collimators designed for imaging mice. METHODS Spatial resolution, image uniformity, point source sensitivity and contrast recovery were determined for the U-SPECT-II (MILabs), the NanoSPECT-NSO (BioScan) and the X-SPECT (GE) scanners. The pinhole diameters of the HR collimator were 0.35 mm, 0.6 mm and 0.5 mm for these three systems respectively. A pinhole diameter of 1 mm was used for the GP collimator. To cover a broad field of imaging applications three isotopes were used with various photon energies: (99m)Tc (140 keV), (111)In (171 and 245 keV) and (125)I (27 keV). Spatial resolution and reconstructed image uniformity were evaluated in both HR and a GP mode with hot rod phantoms, line sources and a uniform phantom. Point source sensitivity and contrast recovery measures were additionally obtained in the GP mode with a novel contrast recovery phantom developed in-house containing hot and cold submillimetre capillaries on a warm background. RESULTS In hot rod phantom images, capillaries as small as 0.4 mm with the U-SPECT-II, 0.75 mm with the X-SPECT and 0.6 mm with the NanoSPECT-NSO could be resolved with the HR collimators for (99m)Tc. The NanoSPECT-NSO achieved this resolution in a smaller field-of-view (FOV) and line source measurements showed that this device had a lower axial than transaxial resolution. For all systems, the degradation in image resolution was only minor when acquiring the more challenging isotopes (111)In and (125)I. The point source sensitivity with (99m)Tc and GP collimators was 3,984 cps/MBq for the U-SPECT-II, 620 cps/MBq for the X-SPECT and 751 cps/MBq for the NanoSPECT-NSO. The effects of volume sensitivity over a larger object were evaluated by measuring the contrast recovery phantom in a realistic FOV and acquisition time. For 1.5-mm rods at a noise level of 8 %, the contrast recovery coefficient (CRC) was 42 %, 37 % and 34 % for the U-SPECT-II, X-SPECT and NanoSPECT-NSO, respectively. At maximal noise levels of 10 %, a CRCcold of 70 %, 52 % and 42 % were obtained for the U-SPECT-II, X-SPECT and NanoSPECT-NSO, respectively. When acquiring (99m)Tc with the GP collimators, the integral/differential uniformity values were 30 %/14 % for the U-SPECT-II, 50 %/30 % for the X-SPECT and 38 %/25 % for the NanoSPECT-NSO. When using the HR collimators, these uniformity values remained similar for U-SPECT-II and X-SPECT, but not for the NanoSPECT-NSO for which the uniformity deteriorated with larger volumes. CONCLUSION We compared three μSPECT systems by acquiring and analysing mouse-sized phantoms including a contrast recovery phantom built in-house offering the ability to measure the hot contrast on a warm background in the submillimetre resolution range. We believe our evaluation addressed the differences in imaging potential for each system to realistically image tracer distributions in mouse-sized objects.
Collapse
Affiliation(s)
- Steven Deleye
- Molecular Imaging Center Antwerp, Antwerp University, Universiteitsplein 1, 2610 Antwerp, Belgium.
| | | | | | | | | | | |
Collapse
|
13
|
Higaki Y, Kobayashi M, Uehara T, Hanaoka H, Arano Y, Kawai K. Appropriate collimators in a small animal SPECT scanner with CZT detector. Ann Nucl Med 2013; 27:271-8. [DOI: 10.1007/s12149-012-0681-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2012] [Accepted: 12/26/2012] [Indexed: 12/29/2022]
|