Hidayat T, Ammarullah MI, Ismail R, Saputra E, Lamura MDP, K N C, Bayuseno AP, Jamari J. Investigation of contact behavior on a model of the dual-mobility artificial hip joint for Asians in different inner liner thicknesses. World J Orthop 2024; 15:321-336. [PMID: 38680676 PMCID: PMC11045469 DOI: 10.5312/wjo.v15.i4.321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 01/28/2024] [Accepted: 03/25/2024] [Indexed: 04/16/2024] Open
Abstract
BACKGROUND The four components that make up the current dual-mobility artificial hip joint design are the femoral head, the inner liner, the outer liner as a metal cover to prevent wear, and the acetabular cup. The acetabular cup and the outer liner were constructed of 316L stainless steel. At the same time, the inner liner was made of ultra-high-molecular-weight polyethylene (UHMWPE). As this new dual-mobility artificial hip joint has not been researched extensively, more tribological research is needed to predict wear. The thickness of the inner liner is a significant component to consider when calculating the contact pressure. AIM To make use of finite element analysis to gain a better understanding of the contact behavior in various inner liner thicknesses on a new model of a dual-mobility artificial hip joint, with the ultimate objective of determining the inner liner thickness that was most suitable for this particular type of dual-mobility artificial hip joint. METHODS In this study, the size of the femoral head was compared between two diameters (28 mm and 36 mm) and eight inner liner thicknesses ranging from 5 mm to 12 mm. Using the finite element method, the contact parameters, including the maximum contact pressure and contact area, have been evaluated in light of the Hertzian contact theory. The simulation was performed statically with dissipated energy and asymmetric behavior. The types of interaction were surface-to-surface contact and normal contact behavior. RESULTS The maximum contact pressures in the inner liner (UHMWPE) at a head diameter of 28 mm and 36 mm are between 3.7-13.5 MPa and 2.7-10.4 MPa, respectively. The maximum von Mises of the inner liner, outer liner, and acetabular cup are 2.4-11.4 MPa, 15.7-44.3 MPa, and 3.7-12.6 MPa, respectively, for 28 mm head. Then the maximum von Mises stresses of the 36 mm head are 1.9-8.9 MPa for the inner liner, 9.9-32.8 MPa for the outer liner, and 2.6-9.9 MPa for the acetabular cup. A head with a diameter of 28 mm should have an inner liner with a thickness of 12 mm. Whereas the head diameter was 36 mm, an inner liner thickness of 8 mm was suitable. CONCLUSION The contact pressures and von Mises stresses generated during this research can potentially be exploited in estimating the wear of dual-mobility artificial hip joints in general. Contact pressure and von Mises stress reduce with an increasing head diameter and inner liner's thickness. Present findings would become one of the references for orthopedic surgery for choosing suitable bearing geometric parameter of hip implant.
Collapse
Affiliation(s)
- Taufiq Hidayat
- Department of Mechanical Engineering, Universitas Muria Kudus, Kudus 59352, Central Java, Indonesia
- Department of Mechanical Engineering, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| | - Muhammad Imam Ammarullah
- Department of Mechanical Engineering, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
- Undip Biomechanics Engineering & Research Centre, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| | - Rifky Ismail
- Department of Mechanical Engineering, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
- Center for Biomechanics Biomaterials Biomechatronics and Biosignal Processing, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| | - Eko Saputra
- Department of Mechanical Engineering, Politeknik Negeri Semarang, Semarang 50275, Central Java, Indonesia
| | - M Danny Pratama Lamura
- Department of Mechanical Engineering, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
- Undip Biomechanics Engineering & Research Centre, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| | - Chethan K N
- Department of Aeronautical and Automobile Engineering, Manipal Institute of Technology, Manipal, Manipal Academy of Higher Education, Manipal 576104, Karnataka, India
| | | | - J Jamari
- Department of Mechanical Engineering, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
- Undip Biomechanics Engineering & Research Centre, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| |
Collapse
|
2
|
Six WR, Koenraadt-van Oost I, van Boekel LC, Bolder SBT. Polyethylene thickness does not influence aseptic revision rate with highly cross-linked liners in THA with 36-mm femoral heads. Hip Int 2024; 34:181-186. [PMID: 37661691 DOI: 10.1177/11207000231196141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/05/2023]
Abstract
BACKGROUND To reduce the risk of dislocation, larger head size can be used in total hip arthroplasty (THA). However, larger head size leads to thinner acetabular liners. With conventional polyethylene, thickness of >8 mm has been advocated to reduce stress and wear rate of the polyethylene. Modern polyethylene has become more wear-resistant. In this study, we investigated if the thickness of sequentially cross-linked polyethylene (XLPE) liners is associated with failure of THA in the medium term. PATIENTS AND METHODS 3654 THAs were included (2009-2016), in which THA was performed with a XLPE liner in combination with a 36-mm femoral head. Patient and surgical characteristics were collected. We compared implant survival of THA with thin liners (<7.9 mm) and thick liners (⩾7.9 mm) with a Kaplan Meier survival analysis at 5 years, median follow-up and 10 years of follow-up with and point aseptic loosening and performed a multivariate analysis to estimate hazard ratios (HR). RESULTS Median follow-up was 7.7 years (IQR 5.6-9.8). In total, 179 revision procedures were performed, where 82 revisions (46%) were performed for aseptic loosening. The survival rate at 5 years, median and 10 years of follow-up showed no statistically significant difference in implant survival. The survival rate at 10 years follow-up was for thin liners 97.1% (95% CI, 96.3-97.9) and for thick liners 98.2% (95% CI, 97.4-99.0) in the aseptic loosening group (chi-square 2.55; p = 0.11).The adjusted HR for thick liners (⩾7.9 mm) was 0.65 (95% CI, 0.38-1.08) compared with the thin liners (<7.9 mm), which was not significantly different. CONCLUSIONS From this single-centre retrospective study it appears that thinner polyethylene liners are well tolerated when using second-generation highly cross-linked polyethylene. Thickness of the XLPE liners did not influence the risk of aseptic loosening of the implants in the medium term.
Collapse
Affiliation(s)
- Willem R Six
- Amphia Ziekenhuis, Breda, North Brabant, The Netherlands
| | | | | | | |
Collapse
|
3
|
Thalody HS, Ponzio DY, Santoro AJ, Radack TM, Post ZD, Ong AC. Large Femoral Heads With Small Acetabular Components: An Examination of 10-Year Polyethylene Wear. Orthopedics 2024; 47:118-122. [PMID: 37561101 DOI: 10.3928/01477447-20230804-07] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/11/2023]
Abstract
Highly cross-linked polyethylene (HXLPE) has improved polyethylene (PE) wear rates while decreasing osteolysis and aseptic loosening. However, concerns exist regarding the risk of mechanical failure with thin HXLPE liners in total hip arthroplasty (THA). Our purpose was to evaluate long-term outcomes and PE wear rates in primary THAs pairing large femoral heads with small acetabular components and thin HXLPE liners. We retrospectively reviewed 29 patients who underwent 33 primary THAs using large femoral heads (32 or 36 mm) with small acetabular components (48 or 50 mm) and thin HXLPE liners (3.9 or 5.9 mm) at minimum 10-year follow-up. PE liner wear was measured using a validated radiographic technique. Mean age was 66 years, 97% of the patients were women, and mean body mass index was 26.3 kg/m2. Thirty hips (90.9%) had ceramic femoral heads, and 13 hips (39%) had 36-mm femoral heads with 3.9-mm HXLPE liners. All cases used a neutral PE design. Mean linear wear rate and volumetric wear rate were 0.04 mm/year and 39.6 mm3/year, respectively, at mean 10.9-year follow-up. There were no instances of liner fracture, liner dissociation, or revision. Mean Hip disability and Osteoarthritis Outcome Score for Joint Replacement (HOOS, JR) was 92.1. In the largest long-term study of primary THAs using large femoral heads with small acetabular components and thin HXLPE liners, we found low linear and volumetric wear rates and no cases of liner mechanical failures. Thin HXLPE liners are a safe and viable option for THA surgeons. [Orthopedics. 2024;47(2):118-122.].
Collapse
|
4
|
Callary SA, Sharma DK, D’Apollonio TM, Campbell DG. Large articulations do not increase wear rates of thin second-generation highly cross-linked polyethylene liners at ten years. Bone Jt Open 2023; 4:839-845. [PMID: 37926113 PMCID: PMC10625862 DOI: 10.1302/2633-1462.411.bjo-2023-0124.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2023] Open
Abstract
Aims Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA. Methods We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point. Results The median proximal, 2D, and 3D wear rates calculated between one and ten years were all less than 0.005 mm/year, with no patient recording a proximal wear rate of more than 0.021 mm/year. Importantly, there was no increase in the wear rate between five and ten years. Conclusion The very low wear rate of X3 XLPE liners with larger articulations remains encouraging for the future clinical performance of this material.
Collapse
Affiliation(s)
- Stuart A. Callary
- Centre for Orthopaedic and Trauma Research, The University of Adelaide and Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia
| | - Deepti K. Sharma
- Centre for Orthopaedic and Trauma Research, The University of Adelaide and Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
| | - Taisha M. D’Apollonio
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia
| | | |
Collapse
|
5
|
Migliorini F, Maffulli N, Pilone M, Bell A, Hildebrand F, Konrads C. Risk factors for liner wear and head migration in total hip arthroplasty: a systematic review. Sci Rep 2023; 13:15612. [PMID: 37730762 PMCID: PMC10511625 DOI: 10.1038/s41598-023-42809-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 09/14/2023] [Indexed: 09/22/2023] Open
Abstract
Total hip arthroplasty (THA) is a successful orthopaedic surgical procedure, and its longevity depends on bearing components and implant fixation. Optimizing polyethylene and ceramics has led to improved wear parameters and contributed to improved long-term outcomes. The present systematic review investigated whether time span from implantation, patient characteristics and performance status exert an influence on liner wear and head migration in THA. This study was conducted in conformity to the 2020 PRISMA guidelines. All the clinical investigations which reported quantitative data on the amount of liner wear and head migration in THA were considered. Only studies which reported quantitative data at least on one of the following patient characteristics were suitable: mean age, mean BMI (kg/m2), sex, side, time span between the index THA and the last follow-up (months) were eligible. A multiple linear model regression analysis was employed to verify the association between patient characteristics and the amount of liner wear and/or head migration. The Pearson Product-Moment Correlation Coefficient was used to assess the association between variables. Data from 12,629 patients were considered. The mean length of the follow-up was 90.5 ± 50.9 months. The mean age of patients at surgery was 58.4 ± 9.4 years, and the mean BMI was 27.2 ± 2.5 kg/m2. 57% (7199 of 12,629 patients) were women, and in 44% (5557 of 12,629 patients) THAs were performed on the left. The mean pre-operative Harris hip score was 46.5 ± 6.0 points. There was evidence of a moderate positive association between the amount of liner wear and the time elapsed between the index surgery to the follow-up (P = 0.02). There was evidence of a moderate positive association between the amount of head migration and the time elapsed between the index surgery to the follow-up (P = 0.01). No further statistically significant association was found. The time elapsed between the index surgery to the follow-up was the most important factor which influence the head migration and liner wear in THA. Patients' characteristics and preoperative physical activity did not influence the amount of head migration and liner wear.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano, Teaching Hospital of Paracelsus Medical University (PMU), 39100, Bolzano, Italy.
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, Simmerath, Germany.
| | - Nicola Maffulli
- Department of Orthopaedic and Trauma Surgery, Hospital Sant'Andrea, University of Rome La Sapienza, Rome, Italy
- School of Pharmacy and Bioengineering, Keele University Faculty of Medicine, Stoke on Trent, ST4 7QB, England
- Queen Mary University of London, Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Mile End Hospital, London, E1 4DG, England
| | - Marco Pilone
- Residency Program in Orthopaedics and Traumatology, University of Milan, 20122, Milan, Italy
| | - Andreas Bell
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, Simmerath, Germany
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Christian Konrads
- Department of Orthopaedics and Traumatology, Helios Hanseatic Hospital Stralsund, 18435, Stralsund, Germany
- Medical Faculty, University of Tübingen, 72076, Tübingen, Germany
| |
Collapse
|
6
|
Jørgensen PB, Kaptein BL, Søballe K, Jakobsen SS, Stilling M. Five-year polyethylene cup migration and PE wear of the Anatomic Dual Mobility acetabular construct. Arch Orthop Trauma Surg 2023; 143:5957-5965. [PMID: 36802237 PMCID: PMC9942043 DOI: 10.1007/s00402-023-04774-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 01/07/2023] [Indexed: 02/23/2023]
Abstract
INTRODUCTION Dual mobility implants have been successful in reducing postoperative hip dislocation but mid-term results of cup migration and polyethylene wear are missing in the literature. Therefore, we measured migration and wear at 5-year follow-up using radiostereometric analysis (RSA). MATERIALS AND METHODS A cohort of 44 patients (mean age 73, 36 female) with heterogeneous indications for hip arthroplasty but all with a high risk of hip dislocation received total hip replacement (THA) with The Anatomic Dual Mobility X3 monoblock acetabular construct and a highly crosslinked polyethylene liner. RSA images and Oxford Hip Scores were obtained perioperatively and 1, 2, and 5 years postoperatively. Cup migration and polyethylene wear were calculated using RSA. RESULTS Mean 2-year proximal cup translation was 0.26 mm (95% CI 0.17; 0.36). Proximal cup translation was stable from 1- to 5-year follow-up. Mean 2-year cup inclination (z-rotation) was 0.23° (95% CI - 0.22; 0.68) and was greater in patients with osteoporosis compared to patients without osteoporosis (p = 0.04). Using 1-year follow-up as baseline, the 3D polyethylene wear rate was 0.07 mm/year (0.05; 0.10). Oxford hip scores improved 19 (95% CI 14; 24) points from mean 21 (range 4; 39) at baseline, to 40 (9; 48) 2 years postoperatively. There were no progressive radiolucent lines > 1 mm. There was 1 revision for offset correction. CONCLUSIONS Anatomic Dual Mobility monoblock cups were well-fixed, the polyethylene wear rate was low, and the clinical outcomes were good until 5-year follow-up suggesting good implant survival in patients of different age groups and with heterogeneous indications for THA.
Collapse
Affiliation(s)
- Peter Bo Jørgensen
- AutoRSA Research Group, Orthopeadic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark.
| | - Bart L Kaptein
- Biomechanics and Imaging Group, Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Kjeld Søballe
- AutoRSA Research Group, Orthopeadic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark
| | - Stig S Jakobsen
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark
| | - Maiken Stilling
- AutoRSA Research Group, Orthopeadic Research Unit, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark
- Department of Orthopaedic Surgery, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark
| |
Collapse
|
7
|
Sax OC, Douglas SJ, Chen Z, Mont MA, Nace J, Delanois RE. Low Wear at 10-Year Follow-Up of a Second-Generation Highly Cross-Linked Polyethylene in Total Hip Arthroplasty. J Arthroplasty 2022; 37:S592-S597. [PMID: 35210151 DOI: 10.1016/j.arth.2022.01.016] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 12/27/2021] [Accepted: 01/06/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Characterizations and factors influencing longer term performance of second-generation sequentially irradiated and annealed highly cross-linked polyethylene (HXLPE) are lacking. We evaluated patients who underwent total hip arthroplasty with HXLPE at mean 10-year follow-up for (1) linear and volumetric wear rates, (2) patient and implant characteristics, (3) implant survivorships, and (4) functional scores. METHODS We evaluated 130 hips (110 patients) that received HXLPE acetabular liners at a single center. The mean age was 56 years (range, 20-79 years), with a mean follow-up of 10 years (range, 8-15). Radiographic linear (millimeters/year) and volumetric (cubic millimeters/year) wear rates were quantified using radiographic analysis. Survivorship was assessed by all-cause and wear-related revision rates. Functional outcomes were assessed by Short Form 12 and modified Harris Hip Scores. RESULTS The mean linear wear rate was 0.02 ± 0.03 mm/y, and the mean volumetric wear rate was 12.6 ± 5.3 mm3/y. Younger age had higher volumetric wear (total and yearly, P = .01). Increasing body mass index trended toward higher total and yearly linear (both, P ≤ .09) and volumetric wear (both, P ≤ .07). Ten patients required revisions, with an all-cause survivorship of 92% and a wear survivorship of 100%. The mean modified Harris Hip Scores was 84, and the mean Short Form 12 scores were 46 (physical) and 55 (mental). CONCLUSION We observed low linear and volumetric wear rates for HXLPE at 10-year mean follow-up. Younger age and higher body mass index at the time of surgery may be important patient characteristics influencing long-term wear. These results illustrate the potential for this second-generation HXLPE to be an appropriate long-term total hip arthroplasty interface.
Collapse
Affiliation(s)
- Oliver C Sax
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| | - Scott J Douglas
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| | - Zhongming Chen
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| | - Michael A Mont
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| | - James Nace
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| | - Ronald E Delanois
- Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, MD
| |
Collapse
|
8
|
Campbell DG, Callary SA. Highly Crosslinked Polyethylene Liners Have Negligible Wear at 10 Years: A Radiostereometric Analysis Study. Clin Orthop Relat Res 2022; 480:485-491. [PMID: 34596603 PMCID: PMC8846270 DOI: 10.1097/corr.0000000000002002] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 09/15/2021] [Indexed: 01/31/2023]
Abstract
BACKGROUND The introduction of crosslinked ultra-high molecular weight polyethylene (XLPE) acetabular liners has been very successful, with decreased wear and reduction in the rates of revision hip arthroplasties. XLPE is the preferred articulation for most surgeons; however, there are concerns about the long-term performance of XLPE liners created with different manufacturing processes, which may lead to time-dependent failure, including accelerated wear, after several years. QUESTIONS/PURPOSES (1) What is the amount and rate of wear during the first 10 years using radiostereometric analysis (RSA) measurements of patients who had THAs that included a second-generation XLPE bearing? (2) Does the rate of wear change after 5 years in situ? METHODS This is a brief follow-up of a previous RSA study. In that study, we prospectively enrolled 21 patients with osteoarthritis who underwent primary cementless THA with an XLPE acetabular liner (three cycles of 3Mrad annealed) and 32-mm articulation. That group represented 44% of the 48 THAs performed by the surgeon at the hospital where RSA was available; 16 had cemented hips, leaving 32 who were invited to participate in this study. Of those, 11 lived rurally and declined to participate, leaving 21 patients who were included in the initial study. Since then, three patients died, one developed dementia and could not participate, and one had revision THA for reasons other than wear, leaving 16 patients available for analysis at 10 years. Tantalum markers were inserted during surgery, and all patients had RSA radiographs taken at 1 week, 6 months, and 1, 2, 5, and 10 years postoperatively. Femoral head penetration into the acetabular component was measured with RSA, including bedding-in during the first year and annual wear thereafter. RESULTS The median medial, proximal, anterior, two-dimensional (2D), and three-dimensional (3D) wear rates between 1 and 10 years were -0.001, 0.004, -0.012, 0.000, and 0.002 mm/year, respectively. No patient in this cohort had a proximal or 2D wear rate greater than 0.025 mm/year. The median proximal wear rate between 5 and 10 years (0.002 mm/year) was not greater than wear at 1 to 5 years (0.004 mm/year). CONCLUSION Femoral head penetration in this second-generation XLPE liner remained very low at 10 years and accelerated wear after 5 years in situ did not occur. Concerns about late-onset wear from oxidation of irradiated-annealed XLPE were not observed. The low level of wear remains encouraging for the future clinical performance of this material. LEVEL OF EVIDENCE Level II, therapeutic study.
Collapse
Affiliation(s)
- David G. Campbell
- Wakefield Orthopaedic Clinic, Adelaide, Australia
- Centre for Orthopaedic and Trauma Research, University of Adelaide, Adelaide, Australia
| | - Stuart A. Callary
- Centre for Orthopaedic and Trauma Research, University of Adelaide, Adelaide, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| |
Collapse
|
9
|
Sequentially Irradiated and Annealed Highly Cross-Linked Polyethylene: Linear Vector and Volumetric Wear in Total Hip Arthroplasty at 10 Years. Arthroplast Today 2021; 11:140-145. [PMID: 34541267 PMCID: PMC8435938 DOI: 10.1016/j.artd.2021.08.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 06/25/2021] [Accepted: 08/03/2021] [Indexed: 11/24/2022] Open
Abstract
Background There is a paucity of data on the long-term performance of highly cross-linked polyethylene (HXLPE). Therefore, this study evaluated 10-year 1) functional, 2) radiographic, and 3) surgical outcomes in patients who underwent total hip arthroplasty with sequentially irradiated and annealed HXLPE. Methods A retrospective, multicenter study was conducted on patients who underwent primary total hip arthroplasty and received HXLPE polymer (n = 151). Two-dimensional radiographic linear and volumetric wear analyses were quantified using the Martell Hip Analysis software, while functional outcomes were assessed by analyzing postoperative Short-Form-12 (SF-12) Physical and Mental Health Surveys and Harris Hip Scores. Radiographic outcomes included yearly linear (mm/y) and volumetric (mm3/y) wear rates. Surgical outcomes included additional operations and survivorship. Results SF-12 scores were within 1 standard deviation (SD) of the normal population (SF-12 Physical: 47.0; SF-12 Mental: 52.0), while the Harris Hip Scores of 89.5 was borderline between “good” and “excellent.” Total and annual linear wear rates were 0.164 mm (SD: 0.199 mm) and 0.015 mm/y (SD: 0.018 mm/y), respectively. The mean total volumetric wear rate was 141.4 mm3 (SD: 165.0) and 12.6 mm3/y (SD: 14.9 mm3/y) when broken down into a yearly rate. Eleven patients required revisions, resulting in an all-cause polyethylene survivorship of 92.7%, with a polyethylene wear survivorship of 100.0%. Conclusions Our results demonstrate clinically undetectable linear and volumetric wear rates after 10 years in those who received the unique sequentially irradiated and annealed HXLPE. Furthermore, high rates of survivorship coupled with low all-cause revision rates illustrate the polymers' capability to potentially increase implant longevity.
Collapse
|
10
|
Grace TR, Goh GS, Lee GC, Kamath AF, Kurtz SM, Courtney PM. Dual Mobility Reduces Dislocations-Why I Use It in All Revisions. J Arthroplasty 2021; 36:S63-S69. [PMID: 33526395 DOI: 10.1016/j.arth.2021.01.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Accepted: 01/05/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Instability remains the most common complication after revision total hip arthroplasty (THA) and presents a unique treatment dilemma for the orthopedic surgeon. Dual mobility (DM) bearing articulations have been used in France since the 1970s, but have only become more widely adopted in the United States over the last decade. The purpose of this symposium was to discuss the role for DM bearings in revision THA. METHODS We reviewed the existing literature on outcomes after DM bearing articulations in revision THA. We also report several case examples of the use of DM in difficult revision THA cases, including acetabular bone loss, failed constrained liner, and adverse local tissue reaction. Finally, we briefly discuss the limitations associated with the use of DM. RESULTS Several large retrospective series demonstrate that DM bearings reduce the incidence of dislocation after revision THA when compared with conventional single bearing THA. Specific complications related to DM bearings including polyethylene wear, loosening, intraprosthetic dislocation, and corrosion remain a concern, but appear to have drastically improved over time with modern implant designs. CONCLUSION Contemporary DM designs have been established as an effective bearing option to reduce instability in revision THA, although concerns do exist. High-quality prospective studies are necessary to further define the role this bearing option has in the coming years.
Collapse
Affiliation(s)
- Trevor R Grace
- Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA
| | - Graham S Goh
- Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA
| | - Gwo-Chin Lee
- Penn Presbyterian Medical Center, University of Pennsylvania School of Medicine, Department of Orthopaedic Surgery, Philadelphia, PA
| | - Atul F Kamath
- Cleveland Clinic, Department of Orthopaedic Surgery, Cleveland, OH
| | - Steven M Kurtz
- Exponent Inc and Drexel University School of Biomedical Engineering, Science, and Health Systems, Philadelphia, PA
| | - P Maxwell Courtney
- Rothman Orthopaedic Institute at Thomas Jefferson University Hospital, Philadelphia, PA
| |
Collapse
|
11
|
Pai FY, Ma HH, Chou TFA, Huang TW, Huang KC, Tsai SW, Chen CF, Chen WM. Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis. BMC Musculoskelet Disord 2021; 22:541. [PMID: 34126990 PMCID: PMC8204435 DOI: 10.1186/s12891-021-04404-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Accepted: 05/24/2021] [Indexed: 02/08/2023] Open
Abstract
Background The aims of this meta-analysis were to: (1) validate the outcome of modern dual mobility (DM) designs in patients who had undergone primary and revision total hip arthroplasty (THA) procedures and (2) to identify factors that affect the outcome. Methods We searched for studies that assessed the outcome of modern DM-THA in primary and revision procedures that were conducted between January, 2000 to August, 2020 on PubMed, MEDLINE, Cochrane Reviews and Embase. The pooled incidence of the most common failure modes and patient reported outcomes were evaluated in patients who have received: (1) primary THA, (2) revision THA for all causes or (3) for recurrent dislocation. A meta-regression analysis was performed for each parameter to determine the association with the outcome. The study design of each study was assessed for potential bias and flaws by using the quality assessment tool for case series studies. Results A total of 119 studies (N= 30016 DM-THAs) were included for analysis. The mean follow-up duration was 47.3 months. The overall implant failure rate was 4.2% (primary: 2.3%, revision for all causes: 5.5%, recurrent dislocation: 6.0%). The most common failure modes were aseptic loosening (primary: 0.9%, revision for all causes: 2.2%, recurrent dislocation: 2.4%), septic loosening (primary:0.8%, revision for all causes: 2.3%, recurrent dislocation: 2.5%), extra-articular dislocation (primary:0.6%, revision for all causes:1.3%, recurrent dislocation:2.5%), intra-prosthetic dislocation (primary:0.8%, revision for all causes:1.0%, recurrent dislocation:1.6%) and periprosthetic fracture (primary:0.9%, revision for all causes:0.9%, recurrent dislocation:1.3%). The multi-regression analysis identified younger age (β=-0.04, 95% CI -0.07 – -0.02) and female patients (β=3.34, 95% CI 0.91–5.78) were correlated with higher implant failure rate. Age, gender, posterolateral approach and body mass index (BMI) were not risk factors for extra-articular or intra-prosthetic dislocation in this cohort. The overall Harris hip score and Merle d’Aubigné score were 84.87 and 16.36, respectively. Level of evidence of this meta-analysis was IV. Conclusion Modern dual-mobility designs provide satisfactory mid-term implant survival and clinical performance. Younger age and female patients might impact the outcome after DM-THA. Future research directions should focus on, (1) long-term outcome of modern dual-mobility design, including specific concerns such as intra-prosthetic dislocation and elevated metal ion, and (2) cost-effectiveness analysis of dual-mobility implant as an alternative to conventional THA for patients who are at high risk of dislocation. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-021-04404-4.
Collapse
Affiliation(s)
- Fu-Yuan Pai
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan.,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan
| | - Hsuan-Hsiao Ma
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan.,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan
| | - Te-Feng Arthur Chou
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan.,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan
| | - Tsan-Wen Huang
- Chang Gung University College of Medicine, Taoyuan, Taiwan.,Department of Orthopaedic Surgery, Chang-Gung Memorial Hospital, Chiayi, Taiwan
| | - Kuo-Chin Huang
- Chang Gung University College of Medicine, Taoyuan, Taiwan.,Department of Orthopaedic Surgery, Chang-Gung Memorial Hospital, Chiayi, Taiwan
| | - Shang-Wen Tsai
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan.,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan
| | - Cheng-Fong Chen
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan. .,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan.
| | - Wei-Ming Chen
- Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, No. 201, Sec 2, Shi-Pai Road, Taipei 112, Taiwan.,Department of Orthopaedics, School of Medicine, National Yang-Ming Chiao-Tung University, Taipei, Taiwan
| |
Collapse
|
12
|
Parekh A, Sood A, Monsef JB, Hamouda M, Hussain A, Gonzalez M. Second-Generation Highly Cross-Linked Polyethylene in Total Hip Arthroplasty. JBJS Rev 2021; 9:e20.00065. [PMID: 33982980 DOI: 10.2106/jbjs.rvw.20.00065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Affiliation(s)
- Amit Parekh
- Department of Orthopaedic Surgery, University of Illinois, Chicago, Illinois
| | - Anshum Sood
- Department of Orthopaedic Surgery, University of Illinois, Chicago, Illinois
| | - Jad Bou Monsef
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Awais Hussain
- Department of Orthopaedic Surgery, University of Illinois, Chicago, Illinois
| | - Mark Gonzalez
- Department of Orthopaedic Surgery, University of Illinois, Chicago, Illinois
| |
Collapse
|
13
|
van Loon J, Hoornenborg D, Sierevelt I, Opdam KTM, Kerkhoffs GMMJ, Haverkamp D. Highly cross-linked versus conventional polyethylene inserts in total hip arthroplasty, a five-year Roentgen stereophotogrammetric analysis randomised controlled trial. World J Orthop 2020; 11:442-452. [PMID: 33134107 PMCID: PMC7582113 DOI: 10.5312/wjo.v11.i10.442] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 06/03/2020] [Accepted: 08/26/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Polyethylene (PE) particles produced by wear of the acetabular insert are thought to cause osteolysis and thereby aseptic loosening of the implant in total hip arthroplasty (THA). As highly cross-linked polyethylene (HXLPE) is presumed to give lower wear rates, in vivo studies are needed to confirm this.
AIM To compare the wear of REXPOL, a HXPLE, with conventional PE within the first five years after implantation using Roentgen stereophotogrammetric analysis (RSA).
METHODS Patients were randomised to receive either a HXLPE (REXPOL) or a conventional PE insert during primary THA. RSA images were obtained directly postoperative and after 6 wk, 12 wk, 6 mo, 12 mo, 24 mo and five years. Functional outcomes were assessed using the Hip Injury and Osteoarthritis Outcome Score and Harris Hip Score at baseline and five years after surgery.
RESULTS The HXLPE (REXPOL) showed less wear in the latero-medial direction. Significant wear rates of conventional PE were seen in the latero-medial and center-proximal direction and in volume and corrected volume, whereas the REXPOL did not show these outcomes over time. Improvement from baseline in functional outcome did not significantly differ.
CONCLUSION Total 3D wear is less in THAs inserted with a REXPOL inlay than a conventional PE inlay after five years. This study confirms, for the first, that the REXPOL HXLPE inlay is preferred to standard PE.
Collapse
Affiliation(s)
- Justin van Loon
- Department of Orthopaedic Surgery, Xpert Orthopedie Amsterdam/Specialized Center of Orthopedic Research and Education, Amsterdam 1101EA, Netherlands
- Department of Orthopaedic Surgery, Amsterdam University Medical Centres, Location Academic Medical Center, Amsterdam 1105AZ, Netherlands
| | - Daniël Hoornenborg
- Department of Orthopaedic Surgery, Xpert Orthopedie Amsterdam/Specialized Center of Orthopedic Research and Education, Amsterdam 1101EA, Netherlands
| | - Inger Sierevelt
- Department of Orthopaedic Surgery, Xpert Orthopedie Amsterdam/Specialized Center of Orthopedic Research and Education, Amsterdam 1101EA, Netherlands
| | - Kim TM Opdam
- Department of Orthopaedic Surgery, Amsterdam University Medical Centres, Location Academic Medical Center, Amsterdam 1105AZ, Netherlands
| | - Gino MMJ Kerkhoffs
- Department of Orthopaedic Surgery, Amsterdam University Medical Centres, Location Academic Medical Center, Amsterdam 1105AZ, Netherlands
| | - Daniël Haverkamp
- Department of Orthopaedic Surgery, Xpert Orthopedie Amsterdam/Specialized Center of Orthopedic Research and Education, Amsterdam 1101EA, Netherlands
| |
Collapse
|
14
|
Van de Kleut ML, Yuan X, Athwal GS, Teeter MG. Validation of In Vivo Linear and Volumetric Wear Measurement for Reverse Total Shoulder Arthroplasty Using Model-Based Radiostereometric Analysis. J Orthop Res 2019; 37:1620-1627. [PMID: 30977541 DOI: 10.1002/jor.24294] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Presently, polyethylene wear measurement of reverse total shoulder arthroplasty (rTSA) is restricted to in vitro, in silico, and retrieval analysis, with no method for the quantification of in vivo wear of well-functioning implants. The purpose of this study was to validate the use of model-based radiostereometric analysis (MBRSA) as a measurement tool for in vivo rTSA wear using a phantom setup. Six additively manufactured polyethylene inserts were fabricated, one unworn control and five to represent known wear patterns, and individually fit within the rTSA components. Each insert was imaged using standard radiostereometric techniques and analyzed using MBRSA. From the position and orientation estimation provided by MBRSA, a micro-computed tomography model of the control insert was virtually placed within the metaphyseal tray. The apparent intersection of the glenosphere into the insert was recorded as wear. This method enables wear measurements with a linear precision of 0.21 mm and a bias of 0.36 ± 0.13 mm, and a volumetric precision of 49.3 mm3 , with a bias of 48.9 ± 24.3 mm3 . This technique allows for the in vivo measurement of polyethylene wear without the requirement of marker beads or baseline radiographs, expanding the potential for in vivo wear measurements to larger populations and retrospective analysis. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1620-1627, 2019.
Collapse
Affiliation(s)
- Madeleine L Van de Kleut
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.,School of Biomedical Engineering, Western University, London, Ontario, Canada.,Lawson Health Research Institute, St. Joseph's Health Care, London, Ontario, Canada
| | - Xunhua Yuan
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| | - George S Athwal
- Lawson Health Research Institute, St. Joseph's Health Care, London, Ontario, Canada.,Department of Surgery, Division of Orthopaedic Surgery, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| | - Matthew G Teeter
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.,School of Biomedical Engineering, Western University, London, Ontario, Canada.,Lawson Health Research Institute, St. Joseph's Health Care, London, Ontario, Canada.,Department of Surgery, Division of Orthopaedic Surgery, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.,Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| |
Collapse
|
15
|
Femoral Head Penetration Rates of Second-Generation Sequentially Annealed Highly Cross-Linked Polyethylene at Minimum Five Years. J Arthroplasty 2019; 34:781-788. [PMID: 30609952 DOI: 10.1016/j.arth.2018.12.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 11/19/2018] [Accepted: 12/04/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Highly cross-linked polyethylene (HXLPE) liners in total hip arthroplasty (THA) have demonstrated decreased wear rates, resilience to cup orientation, and reduced osteolysis compared to conventional polyethylene. Sequential irradiation and annealing below the melting temperature is unique compared to most HXLPE which is irradiated and remelted. This study purpose is to provide minimum 5-year femoral head penetration rates of sequentially annealed HXLPE in primary THA. METHODS A retrospective review of a prospectively collected database identified 198 consecutive, cementless primary THAs utilizing sequentially annealed HXLPE (X3; Stryker, Mahwah, NJ). Operative technique was standardized. Radiographs were analyzed utilizing the Martell method with minimum 5-year and 1-year radiographs as baseline to minimize the initial bedding-in period. RESULTS Seventy-seven hips with minimum 5-year follow-up were analyzed. Mean steady state linear and volumetric head penetration rates were 0.095 mm/y and 76 mm3/y, respectively. Volumetric head penetration was significantly less for 32-mm compared to 36-mm (P = .028). In addition, less head penetration was observed for ceramic 32-mm heads at nearly half the rate compared to cobalt-chromium 36-mm heads (P ≥ .092). No correlations existed between penetration rates and age, body mass index, University of California Los Angeles Activity Level, polyethylene thickness, cup inclination, or anteversion (P ≥ .10). No radiographic osteolysis was observed. CONCLUSION Surprisingly, linear head penetration rates of sequentially annealed HXLPE were nearly identical to the osteolysis threshold for conventional polyethylene and greater than reports of irradiated and remelted HXLPE. Furthermore, these data corroborate reports that HXLPE is resilient to cup orientation and demographic variables. Longer term follow-up is recommended.
Collapse
|
16
|
Kandemir G, Smith S, Joyce TJ. The influence of contact stress on the wear of cross-linked polyethylene. Proc Inst Mech Eng H 2018; 232:1008-1016. [PMID: 30136626 DOI: 10.1177/0954411918796047] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Generation of wear debris and wear particle-induced osteolysis are the main limitations of metal-on-polyethylene artificial joints. Cross-linked polyethylene has been recently used, particularly in hip replacements, as an alternative material to conventional ultrahigh molecular weight polyethylene due to its superior wear resistance. This study focused on the wear behaviour of cross-linked polyethylene under different contact stresses in order to make interpretations of its long-term in-vivo performance. A 50-station SuperCTPOD (pin-on-disc) machine was used to investigate the influence of contact stress on the wear of cross-linked polyethylene pins which were articulated against cobalt chromium discs. It was found that the wear rate of cross-linked polyethylene was lower at higher contact stresses.
Collapse
Affiliation(s)
- Göksu Kandemir
- School of Engineering, Newcastle University, Newcastle upon Tyne, UK
| | - Simon Smith
- School of Engineering, Newcastle University, Newcastle upon Tyne, UK
| | - Thomas J Joyce
- School of Engineering, Newcastle University, Newcastle upon Tyne, UK
| |
Collapse
|
17
|
Muharemovic O, Troelsen A, Thomsen MG, Kallemose T, Gosvig KK. The effect of personalized versus standard patient protocols for radiostereometric analysis (RSA). Radiography (Lond) 2018; 24:e31-e36. [PMID: 29605122 DOI: 10.1016/j.radi.2017.11.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2017] [Revised: 11/18/2017] [Accepted: 11/24/2017] [Indexed: 11/27/2022]
Abstract
INTRODUCTION Increasing pressure in the clinic requires a more standardized approach to radiostereometric analysis (RSA) imaging. The aim of this study was to investigate whether implementation of personalized RSA patient protocols could increase image quality and decrease examination time and the number of exposure repetitions. METHODS Forty patients undergoing primary total hip arthroplasty were equally randomized to either a case or a control group. Radiographers in the case group were assisted by personalized patient protocols containing information about each patient's post-operative RSA imaging. Radiographers in the control group used a standard RSA protocol. RESULTS At three months, radiographers in the case group significantly reduced (p < 0.001) the number of exposures by 1.6, examination time with 19.2 min, and distance between centrum of prosthesis and centrum of calibration field with 34.1 mm when compared to post-operative (baseline) results. At twelve months, the case group significantly reduced (p < 0.001) number of exposures by two, examination time with 22.5 min, and centrum of prosthesis to centrum of calibration field distance with 43.1 mm when compared to baseline results. No significant improvements were found in the control group at any time point. CONCLUSION There is strong evidence that personalized RSA patient protocols have a positive effect on image quality and radiation dose savings. Implementation of personal patient protocols as a RSA standard will contribute to the reduction of examination time, thus ensuring a cost benefit for department and patient safety.
Collapse
Affiliation(s)
- O Muharemovic
- Department of Radiology, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark. mailto:
| | - A Troelsen
- Department of Orthopaedic Surgery, Clinical Orthopedic Research Hvidovre, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark.
| | - M G Thomsen
- Department of Orthopaedic Surgery, Clinical Orthopedic Research Hvidovre, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark.
| | - T Kallemose
- Department of Orthopaedic Surgery, Clinical Orthopedic Research Hvidovre, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark; Clinical Research Center, Copenhagen University Hospital Hvidovre, Kettegaard Alle 30, 2650 Hvidovre, Copenhagen, Denmark.
| | - K K Gosvig
- Department of Radiology, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Copenhagen, Denmark.
| |
Collapse
|
18
|
Pezzotti G, Zhu W, Sugano N, Marin E, Yamamoto K, Nishiike N, Hori T, Rondinella A, McEntire BJ, Bock R, Sonny Bal B. Oxide ceramic femoral heads contribute to the oxidation of polyethylene liners in artificial hip joints. J Mech Behav Biomed Mater 2018; 82:168-182. [PMID: 29601988 DOI: 10.1016/j.jmbbm.2018.03.021] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 03/12/2018] [Accepted: 03/15/2018] [Indexed: 12/01/2022]
Abstract
Experimental evidence demonstrates that a loss of stoichiometry at the surface of oxide bioceramic femoral heads enhances the oxidation rate of polyethylene acetabular liners in artificial hip joints. Contradicting the common notion that ceramics are bioinert, three independent experiments confirmed substantial chemical interactions between the ceramic femoral heads and their polyethylene counterparts. The experiments reported herein included hydrothermal tests, frictional tests, and hip-simulator experiments. It was discovered that oxide and non-oxide femoral heads differently affected the oxidation processes at the surface of the polyethylene liners, all other testing parameters being equal. Analytical data from X-ray photoelectron (XPS), cathodoluminescence (CL), Fourier-transform infrared (FTIR), and Raman spectroscopies unequivocally and consistently showed that the oxidation rate of polyethylene liners was greater when coupled with oxide as opposed to non-oxide ceramic heads. XPS analyses of O-Al-O bond fractions at the surface of a zirconia-toughened alumina (ZTA) short-term (20 months in vivo) femoral heads retrieval showed a ~50% reduction in favor of oxygen vacancy O-Al-VO and hydroxylated Al-O-H bonds. Off-stoichiometry drifts were confirmed in vitro under both static and dynamic conditions. They triggered oxidation and tangibly affected an advanced highly cross-linked sequentially irradiated and annealed ultra-high molecular weight polyethylene (UHMWPE) liner (increase in oxidation index up to ΔOI~1.2 after 5 × 105 cycles under dynamic swing conditions). Second-generation UHMWPE liners infused with vitamin E were also affected by the free flow of oxygen from the oxide femoral heads, although to a lesser extent. The fundamental findings of this study, which were also confirmed on retrievals, call for revised standards in material design and testing. Adopting these new criteria will provide an improved understanding of the importance of off-stoichiometry at the head/liner interface and may lead to significant extensions in artificial joint lifetimes.
Collapse
Affiliation(s)
- Giuseppe Pezzotti
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan; Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishi-Shinjuku, Shinjuku-ku, 160-0023 Tokyo, Japan; The Center for Advanced Medical Engineering and Informatics, Osaka University, Yamadaoka, Suita, 565-0871 Osaka, Japan; Department of Molecular Cell Physiology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kamigyo-ku, 465 Kajii-cho, Kawaramachi dori, 602-0841 Kyoto, Japan; The Center for Advanced Insect Research Promotion (CAIRP), Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan.
| | - Wenliang Zhu
- Department of Medical Engineering for Treatment of Bone and Joint Disorders, Osaka University, 2-2 Yamadaoka, Suita, Osaka 565-0854, Japan
| | - Nobuhiko Sugano
- Department of Medical Engineering for Treatment of Bone and Joint Disorders, Osaka University, 2-2 Yamadaoka, Suita, Osaka 565-0854, Japan
| | - Elia Marin
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan
| | - Kengo Yamamoto
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishi-Shinjuku, Shinjuku-ku, 160-0023 Tokyo, Japan
| | - Naomichi Nishiike
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan
| | - Tsubasa Hori
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan
| | - Alfredo Rondinella
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, 606-8585 Kyoto, Japan
| | - Bryan J McEntire
- Amedica Corporation, 1885 West 2100 South, Salt Lake City, UT 84119, USA
| | - Ryan Bock
- Amedica Corporation, 1885 West 2100 South, Salt Lake City, UT 84119, USA
| | - B Sonny Bal
- Amedica Corporation, 1885 West 2100 South, Salt Lake City, UT 84119, USA; Department of Orthopaedic Surgery, University of Missouri, Columbia, MO 65212, USA
| |
Collapse
|
19
|
Gaudiani MA, White PB, Ghazi N, Ranawat AS, Ranawat CS. Wear Rates With Large Metal and Ceramic Heads on a Second Generation Highly Cross-Linked Polyethylene at Mean 6-Year Follow-Up. J Arthroplasty 2018; 33:590-594. [PMID: 29079168 DOI: 10.1016/j.arth.2017.09.006] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 09/03/2017] [Accepted: 09/05/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Bearing surface wear and osteolysis are major factors limiting the durability of total hip arthroplasty (THA). Second generation annealed highly cross-linked polyethylene (HXLPE) and ceramics were introduced to THA for their excellent wear rates. However, there is little data comparing the wear rates of metal and ceramic heads on second generation HXLPE. METHODS Sixty patients who received a noncemented THA with a 32- or 36-mm delta ceramic head were matched with 60 THAs with a 32- or 36-mm metal head based on gender, head size, follow-up, and University of California, Los Angeles activity score. Linear and volumetric wear rates were measured. RESULTS At mean 6-year follow-up, the mean linear wear rates were 0.012 mm/y (standard deviation [SD] 0.045; 95% confidence interval [CI] 0.001-0.024) and 0.018 mm/y (SD 0.025; 95% CI 0.012-0.025) for the ceramic and metal groups, respectively (P = .724). The mean volumetric wear rates for the ceramic and metal head groups were 11.9 (SD 43.0; 95% CI 0.7-23.0) and 17.3 (SD 23.9; 95% CI 11.1-23.4), respectively. No significant differences were detectable in either the mean linear or volumetric wear rates (P = .380 and P = .398, respectively). CONCLUSION Second generation HXLPE had low wear rates and we were unable to detect a significant difference in wear rates with 32- or 36-mm metal and ceramic heads. We believe that this is due to the excellent tribological properties of second generation HXLPE. We continue to use ceramic as standard of care because of issues of trunnionosis with metal heads.
Collapse
Affiliation(s)
- Michael A Gaudiani
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York
| | - Peter B White
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York
| | - Narges Ghazi
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York
| | - Amar S Ranawat
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York
| | - Chitranjan S Ranawat
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York
| |
Collapse
|
20
|
Abstract
Aims Instability remains a challenging problem in both primary and revision total hip arthroplasty (THA). Dual mobility components confer increased stability, but there are concerns about the unique complications associated with these designs, as well as the long-term survivorship. Materials and Methods We performed a systematic review of all English language articles dealing with dual mobility THAs published between 2007 and 2016 in the MEDLINE and Embase electronic databases. A total of 54 articles met inclusion criteria for the final analysis of primary and revision dual mobility THAs and dual mobility THAs used in the treatment of fractures of the femoral neck. We analysed the survivorship and rates of aseptic loosening and of intraprosthetic and extra-articular dislocation. Results For the 10 783 primary dual mobility THAs, the incidence of aseptic loosening was 1.3% (142 hips); the rate of intraprosthetic dislocation was 1.1% (122 hips) and the incidence of extra-articular dislocation was 0.46% (41 hips). The overall survivorship of the acetabular component and the dual mobility components was 98.0%, with all-cause revision as the endpoint at a mean follow-up of 8.5 years (2 to 16.5). For the 3008 revision dual mobility THAs, the rate of aseptic acetabular loosening was 1.4% (29 hips); the rate of intraprosthetic dislocation was 0.3% (eight hips) and the rate of extra-articular dislocation was 2.2% (67 hips). The survivorship of the acatabular and dual mobility components was 96.6% at a mean of 5.4 years (2 to 8). For the 554 dual mobility THAs which were undertaken in patients with a fracture of the femoral neck, the rate of intraprosthetic dislocation was 0.18% (one hip), the rate of extra-articular dislocation was 2.3% (13 hips) and there was one aseptic loosening. The survivorship was 97.8% at a mean of 1.3 years (0.75 to 2). Conclusion Dual mobility articulations are a viable alternative to traditional bearing surfaces, with low rates of instability and good overall survivorship in primary and revision THAs, and in those undertaken in patients with a fracture of the femoral neck. The incidence of intraprosthetic dislocation is low and limited mainly to earlier designs. High-quality, prospective, comparative studies are needed to evaluate further the use of dual mobility components in THA. Cite this article: Bone Joint J 2018;100-B:11–19.
Collapse
Affiliation(s)
- B. Darrith
- Rush University Medical Center, 1611
W. Harrison St, Suite 300, Chicago, Illinois 60612, USA
| | - P. M. Courtney
- Rothman Institute, Thomas Jefferson University
Hospital, 925 Chestnut St., Phildelphia, 19107, USA
| | - C. J. Della Valle
- Rush University Medical Center, 1611
W. Harrison St, Suite 300, Chicago, Illinois 60612, USA
| |
Collapse
|
21
|
Callary SA, Field JR, Campbell DG. The rate of wear of second-generation highly crosslinked polyethylene liners five years post-operatively does not increase if large femoral heads are used. Bone Joint J 2017; 98-B:1604-1610. [PMID: 27909121 DOI: 10.1302/0301-620x.98b12.37682] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Accepted: 08/12/2016] [Indexed: 01/12/2023]
Abstract
AIMS The increased in vivo resistance to wear of highly crosslinked polyethylene (HXLPE) in total hip arthroplasty (THA) has led to an increased use of larger articulations which have been shown to reduce the incidence of early dislocation. To date, there are few reports of the wear of larger articulations using second generation HXLPE liners. Our prospective cohort study measured the bedding-in and early wear of large (36 mm and 40 mm diameter) articulations involving a second generation X3 HXLPE liner and compared our findings with previous clinical and in vitro studies of the same material. PATIENTS AND METHODS The proximal penetration of the femoral head five years post-operatively was measured for 15 patients using radiostereometric analysis (RSA). RESULTS The median proximal bedding-in within the first post-operative year was 0.022 mm (interquartile range (IQR) -0.050 to 0.091). The median proximal rate of wear between one and five years was -0.004 mm/year (IQR -0.021 to 0.022). The rates of proximal, medial, 2D or 3D wear between one and five years post-operatively of the X3 HXLPE liner did not increase with larger articulations compared with our previous study of 32 mm articulations. CONCLUSION Although reassuring, the use of larger articulations requires continued monitoring to determine whether the low wear observed in the short-term continues to the mid- to long-term. Cite this article: Bone Joint J 2016;98-B:1604-10.
Collapse
Affiliation(s)
- S A Callary
- Royal Adelaide Hospital, Orthopaedics and Trauma, Level 4, Bice Building, North Terrace, Adelaide, South Australia, 5000, Australia
| | - J R Field
- University of Adelaide, Adelaide 5000, South Australia, Australia
| | - D G Campbell
- Wakefield Orthopaedic Clinic, Wakefield Street, Adelaide 5000, South Australia, Australia
| |
Collapse
|
22
|
Samujh C, Bhimani S, Smith L, Malkani AL. Wear Analysis of Second-generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty. Orthopedics 2016; 39:e1178-e1182. [PMID: 27504651 DOI: 10.3928/01477447-20160808-02] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Accepted: 07/13/2016] [Indexed: 02/03/2023]
Abstract
A major limiting factor in the longevity of total hip replacement is the wear rate of the hip bearing. As manufacturing technology has improved during the past several decades, much attention has been focused on developing newer generations of polyethylene that have lower rates of wear while minimizing free radical formation and subsequent osteolysis. The turning point for the manufacture of polyethylene was moving from gamma irradiation in air to irradiation in a low oxygen environment, which reduced free radical formation while increasing the wear resistance. New polyethylene manufacturing methods, including multiple cycles of irradiation and annealing, have resulted in greater wear resistance. Wear analysis studies are essential to determine if these new liners actually show a benefit from prior generations of polyethylene and, more importantly, if they are safe to use. This study involved a single center retrospective review of 60 patients with a mean follow-up of 5.5 years who underwent primary total hip arthroplasty with a second-generation highly cross-linked polyethylene manufactured by 3 cycles of sequential irradiation and annealing. Linear and volumetric wear rates were determined from digitized radiographs using contemporary wear analysis software. The mean linear wear rate for the entire group was 0.025 millimeters per year (mm/y). This value represents a linear wear rate 2.7 times less than that of a first-generation highly cross-linked polyethylene and 4.2 times less than that of a conventional polyethylene. At an average of 5 years, compared with a first-generation highly cross-linked polyethylene, a second-generation highly cross-linked polyethylene appears to show significant improvement regarding wear. [Orthopedics. 2016; 39(6):e1178-e1182.].
Collapse
|
23
|
The result of transmuscular versus transosseous repair of the posterior capsule on early dislocations in primary hip arthroplasty. Hip Int 2016; 25:537-42. [PMID: 26351119 DOI: 10.5301/hipint.5000279] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/19/2015] [Indexed: 02/04/2023]
Abstract
PURPOSE Dislocation is a concerning complication of the posterolateral approach for total hip arthroplasty (THA). Use of a larger size femoral head and a correct repair of the posterior structures can reduce the risk on dislocation of the hip prosthesis. In this study we investigated if there was a difference in dislocation rate between transmuscular and transosseous repair of the posterior soft tissues with use of 36 mm heads. METHODS A power analysis showed that with a standardised effect size of 0.3 and p-value of 0.05, each group should include at least 174 patients. A total of 465 consecutive primary THAs with a posterolateral approach were performed in patients with primary osteoarthritis by 3 orthopaedic surgeons. There were 246 patients operated using transmuscular repair, the other 219 by using transosseous repair. All patients were given the same prostheses. RESULTS Dislocation rate was 1.7% in all patients with at least 1 year follow-up. No significant difference was found in dislocation between both reconstruction techniques. Clinical outcome scores were comparable between the groups. CONCLUSIONS Transosseous and transmuscular repair were equally effective techniques in closing the posterior soft tissues after THA through the posterolateral approach, without difference in dislocation rate or complication rate.
Collapse
|
24
|
Roussignol X, Siedlecki C, Duparc F, Dujardin F, Ould-Slimane M. Do temperature variations at the bearing surface during gait affect polyethylene wear in Charnley low-friction arthroplasty of the hip? Simulator study comparing UHMWPE and highly cross-linked polyethylene. Orthop Traumatol Surg Res 2016; 102:711-5. [PMID: 27318806 DOI: 10.1016/j.otsr.2016.04.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2015] [Revised: 04/01/2016] [Accepted: 04/18/2016] [Indexed: 02/02/2023]
Abstract
INTRODUCTION There are significant individual variations in the polyethylene (PE) wear of Charnley total hip arthroplasty (THA) in published studies. This could be in part related to variations in hip joint kinematics with abnormal heating at the metal/PE interface. The objectives of our hip simulator experiment were: (1) to measure PE wear as a function of hip kinematics and temperature variations at the interface; (2) to compare ultra-high molecular weight polyethylene (UHMWPE) to latest generation highly cross-linked PE (XLPE). HYPOTHESIS Our hypothesis was that PE wear is correlated with temperature increases at the interface and thereby hip joint kinematics. MATERIAL AND METHODS A simulator study was performed with four UHMWPE cups (Initiale™, Amplitude, Valence, France) and two XLPE cups (X3, Stryker, Kalamazoo, Michigan, USA) subjected to 5 million cycles each. The temperature at the femoral head/cup interface was measured every 500 cycles and implant dimensions were measured every 1 million cycles. RESULTS The average temperature was 42°C for 1Hz and 50°C for 1.5Hz, no matter the type of PE tested. There was a large difference between UHMWPE and XLPE in their roughness, but no temperature variations or wear effects. Femoral head penetration after the first 1 million cycles was 0.18mm for the XLPE and 0.075mm UHMWPE on average. Between 1 and 5 million cycles, the penetration was less than 0.1mm per million cycles, with XLPE being similar to UHMPWE. DISCUSSION Our study found a significant temperature increase at the bearing interface as a function of frequency. But there was no correlation between temperature variations and PE degradation. However, shear stresses were under-estimated because our simulator could not reproduce abduction and adduction movements. Our hypothesis was not confirmed because PE deformation was not correlated to temperature variations. XLPE was not better than UHMWPE in the particular conditions of this study. Simulator studies are limited because of the lack of standards on cycling and the simulator bath. LEVEL OF EVIDENCE III-prospective case-control study in vitro.
Collapse
Affiliation(s)
- X Roussignol
- Département de chirurgie orthopédique et traumatologique, CHU de Rouen-Charles-Nicolle, 1, rue de Germont, 76031 Rouen, France.
| | - C Siedlecki
- Département de chirurgie orthopédique et traumatologique, CHU de Rouen-Charles-Nicolle, 1, rue de Germont, 76031 Rouen, France
| | - F Duparc
- Laboratoire d'anatomie, faculté de médecine de Rouen, 22, boulevard Gambetta, 76183 Rouen, France
| | - F Dujardin
- Département de chirurgie orthopédique et traumatologique, CHU de Rouen-Charles-Nicolle, 1, rue de Germont, 76031 Rouen, France
| | - M Ould-Slimane
- Département de chirurgie orthopédique et traumatologique, CHU de Rouen-Charles-Nicolle, 1, rue de Germont, 76031 Rouen, France
| |
Collapse
|
25
|
Selvarajah E, Hooper G, Grabowski K, Frampton C, Woodfield TBF, Inglis G. The rates of wear of X3 highly cross-linked polyethylene at five years when coupled with a 36 mm diameter ceramic femoral head in young patients. Bone Joint J 2016; 97-B:1470-4. [PMID: 26530647 DOI: 10.1302/0301-620x.97b11.35736] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Polyethylene wear debris can cause osteolysis and the failure of total hip arthroplasty. We present the five-year wear rates of a highly cross-linked polyethylene (X3) bearing surface when used in conjunction with a 36 mm ceramic femoral head. This was a prospective study of a cohort of 100 THAs in 93 patients. Pain and activity scores were measured pre- and post-operatively. Femoral head penetration was measured at two months, one year, two years and at five years using validated edge-detecting software (PolyWare Auto). At a mean of 5.08 years (3.93 to 6.01), 85 hips in 78 patients were available for study. The mean age of these patients was 59.08 years (42 to 73, the mean age of males (n = 34) was 59.15 years, and females (n = 44) was 59.02 years). All patients had significant improvement in their functional scores (p < 0.001). The steady state two-dimensional linear wear rate was 0.109 mm/year. The steady state volumetric wear rate was 29.61 mm(3)/year. No significant correlation was found between rate of wear and age (p = 0.34), acetabular component size (p = 0.12) or clinical score (p = 0.74). Our study shows low steady state wear rates at five years in X3 highly cross-linked polyethylene in conjunction with a 36 mm ceramic femoral head. The linear wear rate was almost identical to the osteolysis threshold of 0.1 mm/year recommended in the literature.
Collapse
Affiliation(s)
- E Selvarajah
- Christchurch Public Hospital, 2 Riccarton Avenue, Christchurch 4710, New Zealand
| | - G Hooper
- University of Otago Christchurch, 2 Riccarton Avenue, Christchurch 8011, New Zealand
| | - K Grabowski
- University of Otago Christchurch, 2 Riccarton Avenue, Christchurch 8011, New Zealand
| | - C Frampton
- University of Otago Christchurch, 2 Riccarton Avenue, Christchurch 8011, New Zealand
| | - T B F Woodfield
- University of Otago Christchurch, 2 Riccarton Avenue, Christchurch 8011, New Zealand
| | - G Inglis
- Christchurch Public Hospital, 2 Riccarton Avenue, Christchurch 4710, New Zealand
| |
Collapse
|
26
|
Shareghi B, Johanson PE, Kärrholm J. Femoral Head Penetration of Vitamin E-Infused Highly Cross-Linked Polyethylene Liners: A Randomized Radiostereometric Study of Seventy Hips Followed for Two Years. J Bone Joint Surg Am 2015; 97:1366-71. [PMID: 26290088 DOI: 10.2106/jbjs.n.00595] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Highly cross-linked polyethylene infused with vitamin E (E-poly) was developed to increase oxidative resistance without affecting mechanical properties. We evaluated this type of polyethylene in a randomized clinical study that used radiostereometric analysis. Our objective was to compare the early-term femoral head penetration of an E-poly liner with that of a heat-treated polyethylene liner, ArComXL. We hypothesized that the clinical outcome at two years following total hip arthroplasty would be unaffected by the choice of polyethylene. METHODS In this prospective study, sixty-one patients (seventy hips) with noninflammatory hip osteoarthritis and a median age of fifty-eight years were randomized to receive either an implant with an E-Poly or a heat-treated highly cross-linked polyethylene liner. The patients were followed for two years and evaluated at three time points (three months, one year, and two years). RESULTS The median proximal penetration in the E-poly group increased from 0.04 mm at three months to 0.06 mm at two years of follow-up. Corresponding values for the ArComXL group were 0.03 mm and 0.10 mm. In both groups, significantly increased penetration was observed between three months and two years (E-poly, p = 0.02; ArComXL, p < 0.001), but between one and two years, the increase was significant only in the control group (E-poly, p = 0.23; ArComXL, p = 0.002). CONCLUSIONS The femoral head penetration of E-poly was very low at two years. Whether the increase observed between three months and two years was caused by creep, deformation, wear, or a combination of these cannot be determined by our study. There were no significant differences observed in femoral head penetration rates between E-poly and ArComXL. Currently, the theoretical advantages of E-poly remain to be confirmed.
Collapse
Affiliation(s)
- Bita Shareghi
- Department of Orthopaedics, Sahlgrenska University Hospital, Göteborgsvägen 31, SE-431 80 Mölndal, Sweden. E-mail address for B. Shareghi: . E-mail address for P.-E. Johanson: . E-mail address for J. Kärrholm:
| | - Per-Erik Johanson
- Department of Orthopaedics, Sahlgrenska University Hospital, Göteborgsvägen 31, SE-431 80 Mölndal, Sweden. E-mail address for B. Shareghi: . E-mail address for P.-E. Johanson: . E-mail address for J. Kärrholm:
| | - Johan Kärrholm
- Department of Orthopaedics, Sahlgrenska University Hospital, Göteborgsvägen 31, SE-431 80 Mölndal, Sweden. E-mail address for B. Shareghi: . E-mail address for P.-E. Johanson: . E-mail address for J. Kärrholm:
| |
Collapse
|
27
|
Is the use of thin, highly cross-linked polyethylene liners safe in total hip arthroplasty? INTERNATIONAL ORTHOPAEDICS 2015; 40:681-6. [PMID: 26130285 DOI: 10.1007/s00264-015-2841-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2015] [Accepted: 05/27/2015] [Indexed: 12/28/2022]
Abstract
PURPOSE Due to the high number of total hip arthroplasties (THA) revised due to instability, the use of large femoral heads to reduce instability is justifiable. It is critical to determine whether or not large femoral heads used in conjunction with thin polyethylene liners lead to increased wear rates, which can lead to osteolysis. Therefore, by using validated wear-analysis software, we evaluated linear wear rates in a consecutive cohort of patients who underwent primary THA with thin polyethylene liners. METHODS All patients were selected from a consecutive, prospectively collected database of 241 THAs performed at a single institution by two fellowship-trained joint-reconstruction surgeons between July 2007 and June 2011. These patients were 1:1 matched to a cohort of patients who had conventional-thickness polyethylene liners. RESULTS No significant differences were observed between linear wear rates of thin or conventional-thickness liners. The Kaplan-Meier survivorship for both cohorts was 100 %, and no cases of polyethylene fracture were observed in either cohort. CONCLUSIONS Our results suggest that according to a mean follow-up of 4 years, the use of thin liners in THA is promising. Longer follow-up is required to assess whether these outcomes are observed later.
Collapse
|
28
|
Callary SA, Solomon LB, Holubowycz OT, Campbell DG, Munn Z, Howie DW. Wear of highly crosslinked polyethylene acetabular components. Acta Orthop 2015; 86:159-68. [PMID: 25301435 PMCID: PMC4404765 DOI: 10.3109/17453674.2014.972890] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2014] [Accepted: 08/11/2014] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the in vivo wear of XLPE acetabular components using the most sensitive method available, radiostereometric analysis (RSA). METHODS A systematic search of the PubMed, Scopus, and Cochrane databases was performed to identify published studies in which RSA was used to measure wear of XLPE components in primary total hip arthroplasty (THA). RESULTS 18 publications examined 12 primary THA cohorts, comprising only 260 THAs at 2-10 years of follow-up. The mean or median proximal wear rate reported ranged from 0.00 to 0.06 mm/year. However, differences in the manner in which wear was determined made it difficult to compare some studies. Furthermore, differences in RSA methodology between studies, such as the use of supine or standing radiographs and the use of beaded or unbeaded reference segments, may limit future meta-analyses examining the effect of patient and implant variables on wear rates. INTERPRETATION This scoping review confirmed the low wear rates of XLPE in THA, as measured by RSA. We make recommendations to enhance the standardization of reporting of RSA wear results, which will facilitate early identification of poorly performing implants and enable a better understanding of the effects of surgical and patient factors on wear.
Collapse
|
29
|
Perino G, Ricciardi BF, Jerabek SA, Martignoni G, Wilner G, Maass D, Goldring SR, Purdue PE. Implant based differences in adverse local tissue reaction in failed total hip arthroplasties: a morphological and immunohistochemical study. BMC Clin Pathol 2014; 14:39. [PMID: 25242891 PMCID: PMC4169255 DOI: 10.1186/1472-6890-14-39] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2014] [Accepted: 09/01/2014] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Adverse local tissue reaction (ALTR) is characterized by periprosthetic soft tissue inflammation composed of a mixed inflammatory cell infiltrate, extensive soft tissue necrosis, and vascular changes. Multiple hip implant classes have been reported to result in ALTR, and clinical differences may represent variation in the soft tissue response at the cellular and tissue levels. The purpose of this study was to describe similarities and differences in periprosthetic tissue structure, organization, and cellular composition by conventional histology and immunohistochemistry in ALTR resulting from two common total hip arthroplasty (THA) implant classes. METHODS Consecutive patients presenting with ALTR from two major hip implant classes (N = 54 patients with Dual-Modular Neck implant; N = 14 patients with Metal-on-Metal implant) were identified from our prospective Osteolysis Tissue Database and Repository. Clinical characteristics including age, sex, BMI, length of implantation, and serum metal ion levels were recorded. Retrieved synovial tissue morphology was graded using light microscopy and cellular composition was assessed using immunohistochemistry. RESULTS Length of implantation was shorter in the DMN group versus MoM THA group (21.3 [8.4] months versus 43.6 [13.8] months respectively; p < 0.005) suggesting differences in implant performance. Morphologic examination revealed a common spectrum of neo-synovial proliferation and necrosis in both groups. Macrophages were more commonly present in diffuse sheets (Grade 3) in the MoM relative to DMN group (p = 0.016). Perivascular lymphocytes with germinal centers (Grade 4) were more common in the DMN group, which trended towards significance (p = 0.066). Qualitative differences in corrosion product morphology were seen between the two groups. Immunohistochemistry showed features of a CD4 and GATA-3 rich lymphocyte reaction in both implants, with increased ratios of perivascular T-cell relative to B-cell markers in the DMN relative to the MoM group (p = 0.032). CONCLUSION Our results demonstrate that both implant classes display common features of neo-synovial proliferation and necrosis with a CD4 and GATA-3 rich inflammatory infiltrate. Qualitative differences in corrosion product appearance, macrophage morphology, and lymphocyte distributions were seen between the two implant types. Our data suggests that ALTR represents a histological spectrum with implant-based features.
Collapse
Affiliation(s)
- Giorgio Perino
- Department of Pathology, Hospital for Special Surgery, 535 East 70th Street, New York NY 10021, USA
| | - Benjamin F Ricciardi
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Seth A Jerabek
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | - Guido Martignoni
- Department of Pathology and Diagnostics, University of Verona, Verona and Pederzoli Hospital, Peschiera, Italy
| | - Gabrielle Wilner
- Division of Research, Hospital for Special Surgery, New York, NY, USA
| | - Dan Maass
- Division of Research, Hospital for Special Surgery, New York, NY, USA
| | - Steven R Goldring
- Division of Research, Hospital for Special Surgery, New York, NY, USA
| | - P Edward Purdue
- Division of Research, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
30
|
Madanat R, Mäkinen TJ, Aro HT, Bragdon C, Malchau H. Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review. Acta Orthop 2014; 85:447-55. [PMID: 24954489 PMCID: PMC4164860 DOI: 10.3109/17453674.2014.934187] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Guidelines for standardization of radiostereometry (RSA) of implants were published in 2005 to facilitate comparison of outcomes between various research groups. In this systematic review, we determined how well studies have adhered to these guidelines. METHODS We carried out a literature search to identify all articles published between January 2000 and December 2011 that used RSA in the evaluation of hip or knee prosthesis migration. 2 investigators independently evaluated each of the studies for adherence to the 13 individual guideline items. Since some of the 13 points included more than 1 criterion, studies were assessed on whether each point was fully met, partially met, or not met. RESULTS 153 studies that met our inclusion criteria were identified. 61 of these were published before the guidelines were introduced (2000-2005) and 92 after the guidelines were introduced (2006-2011). The methodological quality of RSA studies clearly improved from 2000 to 2011. None of the studies fully met all 13 guidelines. Nearly half (43) of the studies published after the guidelines demonstrated a high methodological quality and adhered at least partially to 10 of the 13 guidelines, whereas less than one-fifth (11) of the studies published before the guidelines had the same methodological quality. Commonly unaddressed guideline items were related to imaging methodology, determination of precision from double examinations, and also mean error of rigid-body fitting and condition number cutoff levels. INTERPRETATION The guidelines have improved methodological reporting in RSA studies, but adherence to these guidelines is still relatively low. There is a need to update and clarify the guidelines for clinical hip and knee arthroplasty RSA studies.
Collapse
Affiliation(s)
- Rami Madanat
- Helsinki University Central Hospital, Helsinki,Harris Orthopaedic Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | | | - Hannu T Aro
- Turku University Hospital and University of Turku, Turku, Finland
| | - Charles Bragdon
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
31
|
No differences found in bearing related hip survivorship at 10-12 years follow-up between patients with ceramic on highly cross-linked polyethylene bearings compared to patients with ceramic on ceramic bearings. J Arthroplasty 2014; 29:1369-72. [PMID: 24674733 DOI: 10.1016/j.arth.2014.02.025] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2013] [Revised: 01/09/2014] [Accepted: 02/18/2014] [Indexed: 02/01/2023] Open
Abstract
At a minimum follow-up of ten years we compared clinical and radiographic findings and survivorship in a cohort of 412 patients (447 hips) who received alumina on alumina CoC bearings to findings from a cohort of 216 patients (228 hips) with alumina on highly cross-linked polyethylene (HXLPE) bearings. All patients were operated for osteoarthritis. With bearing-related complications as endpoint, analysis showed no significant difference in survivorship between cohorts (99.8% for the CoC vs. 99.4% for HXLPE). In addition, there were no significant differences in clinical and radiographic findings between cohorts. We concluded that alumina on HXLPE bearings are a reasonable lower cost alternative to ceramic on ceramic bearing couples.
Collapse
|
32
|
Takahashi Y, Sugano N, Puppulin L, Zhu W, Pezzotti G. Raman spectroscopic study of remelting and annealing-induced effects on microstructure and compressive deformation behavior of highly crosslinked UHMWPE for total hip arthroplasty. J Biomed Mater Res B Appl Biomater 2014; 102:1762-70. [PMID: 24700660 DOI: 10.1002/jbm.b.33164] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2013] [Revised: 12/24/2013] [Accepted: 03/19/2014] [Indexed: 11/12/2022]
Abstract
Three-dimensional crystallographic morphologies were studied by means of confocal/polarized Raman spectroscopy as developed upon manufacturing in three different types of first and second generation highly crosslinked UHMWPE (HXLPE) acetabular liners. The impact of such microstructural characteristics on the deformation behavior of the liners was also evaluated and discussed from the viewpoint of molecular chain mobility. All the investigated liners showed similar microstructural transitions within the first 35 μm below their surfaces in terms of crystallinity, molecular orientation, and crystalline anisotropy. Interestingly, different postirradiation heat treatments (remelting or annealing in single step or in sequential steps) led to clear differences in the subsurface microstructure among the three liners. Remelted liner possessed both lower bulk crystallinity and degree of molecular orientation as compared to the annealed liners. Sequentially, irradiated/annealed liner showed the highest degree of crystallinity and orientation among the studied liners. The peculiar microstructure of this latter liner exhibited the highest restoring (shape-recovery) force against the applied uniaxial strain. Accordingly, the present study suggests that the sequential irradiation and annealing offers an efficient way to obtain microstructure quite suitable for attaining high creep resistance. However, all the investigated liners exhibited the significantly low values of surface anisotropy, which could be equally efficient in minimizing strain-softening-assisted wear phenomena.
Collapse
Affiliation(s)
- Yasuhito Takahashi
- Ceramic Physics Laboratory, Kyoto Institute of Technology, Sakyo-ku, Matsugasaki, Kyoto 606-8585, Japan; Department of Orthopaedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo 160-0023, Japan
| | | | | | | | | |
Collapse
|
33
|
Pezzotti G, Yamamoto K. Artificial hip joints: The biomaterials challenge. J Mech Behav Biomed Mater 2014; 31:3-20. [DOI: 10.1016/j.jmbbm.2013.06.001] [Citation(s) in RCA: 65] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2013] [Revised: 05/29/2013] [Accepted: 06/06/2013] [Indexed: 12/21/2022]
|
34
|
Johnson AJ, Loving L, Herrera L, Delanois RE, Wang A, Mont MA. Short-term wear evaluation of thin acetabular liners on 36-mm femoral heads. Clin Orthop Relat Res 2014; 472:624-9. [PMID: 23861047 PMCID: PMC3890177 DOI: 10.1007/s11999-013-3153-x] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Dislocation remains the leading cause of revision THA. One approach to decreasing prosthetic dislocation risk has been the use of larger femoral head component sizes. The upper limit of head size in metal-on-polyethylene hip arthroplasty has historically been limited because of concerns about increased wear on thin polyethylene components. It is not known to what degree this concern should apply to more wear-resistant polyethylene components. QUESTIONS/PURPOSES We therefore determined (1) in vitro wear rates of polyethylene liners of varying thicknesses, (2) whether there were differences in the microscopic wear characteristics as a function of polyethylene thickness, and (3) whether thin polyethylene components resulted in early catastrophic failures. METHODS We used a hip wear simulator to compare the wear performance of 12 highly crosslinked polyethylene acetabular inserts. The internal diameter of all components was 36 mm, and there were three samples tested of each thickness (1.9, 3.9, 5.9, or 7.9 mm). Testing was conducted for 2.4 million cycles. Gravimetric mass loss was converted to volumetric loss, which was subsequently converted to theoretical linear penetration rates. RESULTS Wear rates decreased with increasing polyethylene thickness. Mean ± SD wear rates for the 1.9-, 3.9-, 5.9-, and 7.9-mm groups were 5.0 ± 0.5, 3.2 ± 0.3, 2.5 ± 1.1, and 2.2 ± 1.3 mm(3)/million cycles, respectively (p < 0.016). Calculated penetration rates were 0.015, 0.012, 0.011, and 0.010 mm/million cycles, respectively (p < 0.016). There were no catastrophic failures in any group. CONCLUSIONS Thinner polyethylene components demonstrated higher wear rates, although even the highest wear rate observed in the thinnest polyethylene specimen was lower than that commonly reported for noncrosslinked polyethylene components. While encouraging, these findings should be validated in vivo before clinical recommendations can be made.
Collapse
Affiliation(s)
- Aaron J. Johnson
- />Center for Joint Preservation and Reconstruction, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD 21215 USA
| | | | | | - Ronald E. Delanois
- />Center for Joint Preservation and Reconstruction, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD 21215 USA
| | | | - Michael A. Mont
- />Center for Joint Preservation and Reconstruction, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, MD 21215 USA
| |
Collapse
|
35
|
Selvarajah E, Hooper GJ, Woodfield TB, Inglis G, Frampton C. Measurement of early wear rates with X3 polyethylene and 36-mm femoral heads in young patients – a prospective study. CURRENT ORTHOPAEDIC PRACTICE 2013. [DOI: 10.1097/bco.0b013e31829cc4c9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
36
|
Callary SA, Field JR, Campbell DG. Low wear of a second-generation highly crosslinked polyethylene liner: a 5-year radiostereometric analysis study. Clin Orthop Relat Res 2013; 471:3596-600. [PMID: 23893361 PMCID: PMC3792282 DOI: 10.1007/s11999-013-3188-z] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2013] [Accepted: 07/15/2013] [Indexed: 01/31/2023]
Abstract
BACKGROUND A sequentially irradiated and annealed, second-generation highly crosslinked polyethylene (XLPE) liner was introduced clinically in 2005 to reduce in vivo oxidation. This liner design has also been shown to reduce wear in vitro when compared with conventional and first-generation crosslinked liners. To date, there is only one study reporting an in vivo wear rate of this liner at 5 years' followup. However, that study used measurements made from plain radiographs, which have limited sensitivity, particularly when monitoring very low amounts of wear. QUESTIONS/PURPOSES What is the amount and direction of wear at 5 years using radiostereometric analysis (RSA) in patients who had THAs that included second-generation XLPE? METHODS We prospectively reviewed 21 patients who underwent primary cementless THA with the same design of XLPE acetabular liner and 32-mm articulation. Tantalum markers were inserted during surgery and all patients had RSA radiographs at 1 week, 6 months, and 1, 2, and 5 years postoperatively. Femoral head penetration within the acetabular component was measured with UmRSA(®) software. One patient died and two had incomplete radiographs leaving 18 radiographic series for analysis. RESULTS The mean amounts of proximal, two-dimensional, and three-dimensional head penetration between 1 week and 5 years were 0.018, 0.071, and 0.149 mm, respectively. The mean proximal, two-dimensional, and three-dimensional wear rates calculated between 1 year and 5 years were all less than 0.001 mm/year with no patient recording a wear rate of more than 0.040 mm/year. CONCLUSIONS The head penetration of a second-generation XLPE liner remained low at 5 years and the wear rate calculated after the first year was low in all directions. This low level of wear remains encouraging for the future clinical performance of this material.
Collapse
Affiliation(s)
- Stuart A Callary
- Centre for Orthopaedic and Trauma Research, Level 4 Bice Building, University of Adelaide and Royal Adelaide Hospital, North Terrace, Adelaide, 5000, South Australia, Australia,
| | | | | |
Collapse
|
37
|
Zietz C, Fabry C, Middelborg L, Fulda G, Mittelmeier W, Bader R. Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2013; 24:2057-2065. [PMID: 23615788 DOI: 10.1007/s10856-013-4936-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2012] [Accepted: 04/19/2013] [Indexed: 06/02/2023]
Abstract
Larger femoral heads lead to a decreased risk of total hip dislocation and an improved range of motion. However, the larger diameter is associated with increased wear rates. The low wear rates of crosslinked polyethylene opens up the possibility of using larger heads. The aim of this experimental study was to evaluate the wear of conventional non-crosslinked versus sequentially crosslinked polyethylene liners in combination with different ceramic head sizes (28, 36, 44 mm). Wear testing was performed in a hip simulator according to ISO 14242. Wear particles from the polyethylene liners were characterized after wear testing. The wear measurements revealed a significant increase in the wear of crosslinked polyethylene liners with larger heads. By sequential crosslinking, however, the gravimetric wear using larger heads was reduced to a fractional amount of the wear using conventional polyethylene. Significant differences were observed for particle morphology but not for the number of particles when comparing non-crosslinked and crosslinked polyethylene.
Collapse
Affiliation(s)
- Carmen Zietz
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, University Medicine Rostock, Doberaner Straße 142, 18057, Rostock, Germany.
| | | | | | | | | | | |
Collapse
|
38
|
Loving L, Lee RK, Herrera L, Essner AP, Nevelos JE. Wear performance evaluation of a contemporary dual mobility hip bearing using multiple hip simulator testing conditions. J Arthroplasty 2013; 28:1041-6. [PMID: 23434106 DOI: 10.1016/j.arth.2012.09.011] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2012] [Revised: 08/29/2012] [Accepted: 09/18/2012] [Indexed: 02/01/2023] Open
Abstract
The dual mobility hip bearing concept combines a small bearing with a large diameter bearing through a dual articulation system, potentially increasing the stability of the hip. Bearings with two articulations introduce concerns of whether or not wear might be increased compared to a conventional bearing. We therefore evaluated the wear performance of a dual mobility hip bearing using sequentially cross-linked and annealed polyethylene under the conditions of impingement, abrasion, and when the mobile liner becomes immobilized at either the inner or outer diameter. We found the wear performance of this dual mobility hip is dictated by the conditions experienced by the smaller inner articulation and by the polyethylene material. The highest wearing group wore 75% less than a single articulating conventional gamma/inert polyethylene bearing.
Collapse
Affiliation(s)
- Laquawn Loving
- Stryker Orthopaedics, 325 Corporate Dr. Mahwah, New Jersey, USA
| | | | | | | | | |
Collapse
|
39
|
Second-generation annealed highly cross-linked polyethylene exhibits low wear. Clin Orthop Relat Res 2012; 470:1696-704. [PMID: 22161120 PMCID: PMC3348318 DOI: 10.1007/s11999-011-2177-3] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2011] [Accepted: 11/02/2011] [Indexed: 02/07/2023]
Abstract
BACKGROUND Compared with conventional polyethylene, first-generation highly cross-linked polyethylenes have low wear, but controversy exists regarding their reduced mechanical strength and/or retained free radicals. Second-generation highly cross-linked polyethylenes have been developed to reduce wear, maintain mechanical strength, and have oxidative resistance, but it is unclear whether they do so. QUESTIONS/PURPOSES The primary objective of this study therefore was to determine if a second-generation annealed material has low linear wear at 5 years followup. Secondary objectives were to evaluate for overall survivorship, implant fixation, osteolysis, and effect of socket inclination on wear. METHODS In a multicenter prospective study, we radiographically evaluated 155 patients (167 hips) at 3 years, 124 patients (132 hips) at 4 years, and 46 patients (51 hips) at 5 years. The linear head penetration rate was measured at 6 weeks, 1 year, and yearly through 5 years. RESULTS The head penetration per year after the first year of bedding-in was 0.024 mm per year at 3 years, 0.020 mm per year at 4 years, and 0.008 mm per year at 5 years. The average wear rate over 5 years was 0.015 mm per year and represents a 58% improvement over a first-generation annealed highly cross-linked polyethylene. The Kaplan-Meier survivorship (revision for any reason) was 97.8%. We revised no hip for bearing surface failure and observed no osteolysis. Socket inclination did not affect linear wear. CONCLUSIONS These data suggest the linear wear rate for a second-generation annealed highly cross-linked polyethylene is no greater than that for historic controls of first-generation highly cross-linked polyethylenes, and no untoward complications were encountered with this new material. LEVEL OF EVIDENCE Level II, prognostic study. See the Guidelines for Authors for a complete description of levels of evidence.
Collapse
|