1
|
Rahmati M, Silva EA, Reseland JE, A Heyward C, Haugen HJ. Biological responses to physicochemical properties of biomaterial surface. Chem Soc Rev 2020; 49:5178-5224. [PMID: 32642749 DOI: 10.1039/d0cs00103a] [Citation(s) in RCA: 137] [Impact Index Per Article: 34.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Biomedical scientists use chemistry-driven processes found in nature as an inspiration to design biomaterials as promising diagnostic tools, therapeutic solutions, or tissue substitutes. While substantial consideration is devoted to the design and validation of biomaterials, the nature of their interactions with the surrounding biological microenvironment is commonly neglected. This gap of knowledge could be owing to our poor understanding of biochemical signaling pathways, lack of reliable techniques for designing biomaterials with optimal physicochemical properties, and/or poor stability of biomaterial properties after implantation. The success of host responses to biomaterials, known as biocompatibility, depends on chemical principles as the root of both cell signaling pathways in the body and how the biomaterial surface is designed. Most of the current review papers have discussed chemical engineering and biological principles of designing biomaterials as separate topics, which has resulted in neglecting the main role of chemistry in this field. In this review, we discuss biocompatibility in the context of chemistry, what it is and how to assess it, while describing contributions from both biochemical cues and biomaterials as well as the means of harmonizing them. We address both biochemical signal-transduction pathways and engineering principles of designing a biomaterial with an emphasis on its surface physicochemistry. As we aim to show the role of chemistry in the crosstalk between the surface physicochemical properties and body responses, we concisely highlight the main biochemical signal-transduction pathways involved in the biocompatibility complex. Finally, we discuss the progress and challenges associated with the current strategies used for improving the chemical and physical interactions between cells and biomaterial surface.
Collapse
Affiliation(s)
- Maryam Rahmati
- Department of Biomaterials, Institute of Clinical Dentistry, University of Oslo, 0317 Oslo, Norway. h.j.haugen.odont.uio.no
| | | | | | | | | |
Collapse
|
2
|
Rath D, Kumar S, Panda S. pH-Based Detection of Target Analytes in Diluted Serum Samples Using Surface Plasmon Resonance Immunosensor. Appl Biochem Biotechnol 2018; 187:1272-1284. [PMID: 30218300 DOI: 10.1007/s12010-018-2883-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Accepted: 09/09/2018] [Indexed: 12/01/2022]
Abstract
Detection of minute quantities of target antigens in serum samples (consisting of a mixture of proteins/biomolecules) can be achieved by enhancement of the capture efficiencies of heterogeneous immunosensors. An important process parameter which affects the capture of target analytes in such immunosensors is the pH of the solution as the target proteins present in the serum samples are charged molecules. Here, we investigated the capture of prostate-specific antigens (PSAs), first in a mixed-analyte system wherein the solution contained two other non-specific proteins along with the target analyte, using the surface plasmon resonance spectroscopy. There are no reports on the detection of antigens in a mixed system based on the optimization of the pH values of the carrier fluid, and this is the motivation of the present work. Further, we studied interference effects caused by the presence of these non-specific proteins in the mixed-analyte systems by artificially increasing the ratio of the interfering proteins to that of the target protein. Eventually PSA spiked into the rabbit serum samples was captured through the optimization of the pH of the solution. We could detect PSA in the serum samples when diluted to 100 times or more, where the amounts of other interfering proteins were ~ 66 times that of the amount of PSA. This study proposes a heterogeneous immunosensor to detect the target analytes in the diluted serum samples by tuning pH the of solution mixture, which can be utilized to detect disease biomarkers in serum samples.
Collapse
Affiliation(s)
| | - Satyendra Kumar
- Department of Chemical Engineering, Kanpur, India.,Samtel Centre for Display Technologies, Indian Institute of Technology Kanpur, Kanpur, UP, 208 016, India
| | - Siddhartha Panda
- Department of Chemical Engineering, Kanpur, India. .,Samtel Centre for Display Technologies, Indian Institute of Technology Kanpur, Kanpur, UP, 208 016, India.
| |
Collapse
|
3
|
Wordofa DN, Ramnani P, Tran TT, Mulchandani A. An oligonucleotide-functionalized carbon nanotube chemiresistor for sensitive detection of mercury in saliva. Analyst 2018; 141:2756-60. [PMID: 26902487 DOI: 10.1039/c6an00018e] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Divalent mercuric (Hg(2+)) ion and monomethyl mercury (CH3Hg(+)) are two forms of mercury that are known to be highly toxic to humans. In this work, we present a highly selective, sensitive and label-free chemiresistive biosensor for the detection of both, Hg(2+) and CH3Hg(+) ions using DNA-functionalized single-walled carbon nanotubes (SWNTs). The SWNTs were functionalized with the capture oligonucleotide, polyT, using a linker molecule. The polyT was hybridized with polyA to form a polyT:polyA duplex. Upon exposure to mercury ions, the polyT:polyA duplex dehybridizes and a T-Hg(2+)-T duplex is formed. This structure switch leads to the release of polyA from the SWNT surface and correspondingly a change in the resistance of the chemiresistive biosensor is observed, which is used to quantify the mercury ion concentration. The biosensor showed a wide dynamic range of 0.5 to 100 nM for the detection of CH3Hg(+) ions in buffer solution with a sensitivity of 28.34% per log (nM) of CH3Hg(+). Finally, real world application of the biosensor was demonstrated by the detection of Hg(2+) and CH3Hg(+) ions in simulated saliva samples spiked with a known concentration of mercury ions.
Collapse
Affiliation(s)
- Dawit N Wordofa
- Department of Chemical and Environmental Engineering, University of California, Riverside, California 92521, USA.
| | - Pankaj Ramnani
- Department of Chemical and Environmental Engineering, University of California, Riverside, California 92521, USA.
| | - Thien-Toan Tran
- Department of Bioengineering, University of California, Riverside, California 92521, USA
| | - Ashok Mulchandani
- Department of Chemical and Environmental Engineering, University of California, Riverside, California 92521, USA. and Material Science and Engineering Program, University of California, Riverside, California 92521, USA
| |
Collapse
|
4
|
|
5
|
Wronska MA, O'Connor IB, Tilbury MA, Srivastava A, Wall JG. Adding Functions to Biomaterial Surfaces through Protein Incorporation. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2016; 28:5485-5508. [PMID: 27164952 DOI: 10.1002/adma.201504310] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2015] [Revised: 03/16/2016] [Indexed: 06/05/2023]
Abstract
The concept of biomaterials has evolved from one of inert mechanical supports with a long-term, biologically inactive role in the body into complex matrices that exhibit selective cell binding, promote proliferation and matrix production, and may ultimately become replaced by newly generated tissues in vivo. Functionalization of material surfaces with biomolecules is critical to their ability to evade immunorecognition, interact productively with surrounding tissues and extracellular matrix, and avoid bacterial colonization. Antibody molecules and their derived fragments are commonly immobilized on materials to mediate coating with specific cell types in fields such as stent endothelialization and drug delivery. The incorporation of growth factors into biomaterials has found application in promoting and accelerating bone formation in osteogenerative and related applications. Peptides and extracellular matrix proteins can impart biomolecule- and cell-specificities to materials while antimicrobial peptides have found roles in preventing biofilm formation on devices and implants. In this progress report, we detail developments in the use of diverse proteins and peptides to modify the surfaces of hard biomaterials in vivo and in vitro. Chemical approaches to immobilizing active biomolecules are presented, as well as platform technologies for isolation or generation of natural or synthetic molecules suitable for biomaterial functionalization.
Collapse
Affiliation(s)
- Małgorzata A Wronska
- Microbiology and Center for Research in Medical Devices (CÚRAM), National University of Ireland, Galway, Ireland
| | - Iain B O'Connor
- Microbiology and Center for Research in Medical Devices (CÚRAM), National University of Ireland, Galway, Ireland
| | - Maura A Tilbury
- Microbiology and Center for Research in Medical Devices (CÚRAM), National University of Ireland, Galway, Ireland
| | - Akshay Srivastava
- Microbiology and Center for Research in Medical Devices (CÚRAM), National University of Ireland, Galway, Ireland
| | - J Gerard Wall
- Microbiology and Center for Research in Medical Devices (CÚRAM), National University of Ireland, Galway, Ireland
| |
Collapse
|
6
|
Fadel TR, Farrell DF, Friedersdorf LE, Griep MH, Hoover MD, Meador MA, Meyyappan M. Toward the Responsible Development and Commercialization of Sensor Nanotechnologies. ACS Sens 2016; 1:207-216. [PMID: 28261665 PMCID: PMC5332131 DOI: 10.1021/acssensors.5b00279] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Nanotechnology-enabled sensors (or nanosensors) will play an important role in enabling the progression toward ubiquitous information systems as the Internet of Things (IoT) emerges. Nanosensors offer new, miniaturized solutions in physiochemical and biological sensing that enable increased sensitivity, specificity, and multiplexing capability, all with the compelling economic drivers of low cost and high-energy efficiency. In the United States, Federal agencies participating in the National Nanotechnology Initiative (NNI) "Nanotechnology for Sensors and Sensors for Nanotechnology: Improving and Protecting Health, Safety, and the Environment" Nanotechnology Signature Initiative (the Sensors NSI), address both the opportunity of using nanotechnology to advance sensor development and the challenges of developing sensors to keep pace with the increasingly widespread use of engineered nanomaterials. This perspective article will introduce and provide background on the NNI signature initiative on sensors. Recent efforts by the Sensors NSI aimed at promoting the successful development and commercialization of nanosensors will be reviewed and examples of sensor nanotechnologies will be highlighted. Future directions and critical challenges for sensor development will also be discussed.
Collapse
Affiliation(s)
- Tarek R. Fadel
- The National Nanotechnology Coordination Office, 4201 Wilson Boulevard, Suite 405, Arlington, Virginia 22230, United States
| | - Dorothy F. Farrell
- The National Cancer Institute, National Institutes of Health, 31 Center Drive, 10A52, Bethesda, Maryland 20892, United States
| | - Lisa E. Friedersdorf
- The National Nanotechnology Coordination Office, 4201 Wilson Boulevard, Suite 405, Arlington, Virginia 22230, United States
| | - Mark H. Griep
- The U.S. Army Research Laboratory, Aberdeen Proving Ground, Aberdeen, Maryland 21005, United States
| | - Mark D. Hoover
- The National Institute for Occupational Safety and Health, 1095 Willowdale Road, Morgantown, West Virginia 26505, United States
| | - Michael A. Meador
- The National Nanotechnology Coordination Office, 4201 Wilson Boulevard, Suite 405, Arlington, Virginia 22230, United States
| | - M. Meyyappan
- Center for Nanotechnology, NASA Ames Research Center, Moffett Field, California 94035, United States
| |
Collapse
|
7
|
Ramnani P, Saucedo NM, Mulchandani A. Carbon nanomaterial-based electrochemical biosensors for label-free sensing of environmental pollutants. CHEMOSPHERE 2016; 143:85-98. [PMID: 25956023 DOI: 10.1016/j.chemosphere.2015.04.063] [Citation(s) in RCA: 91] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2014] [Revised: 04/17/2015] [Accepted: 04/21/2015] [Indexed: 05/15/2023]
Abstract
Carbon allotropes such as graphene and carbon nanotubes, have been incorporated in electrochemical biosensors for highly sensitive and selective detection of various analytes. The superior physical and electrical properties like high carrier mobility, ambipolar electric field effect, high surface area, flexibility and their compatibility with microfabrication techniques makes these carbon nanomaterials easy to integrate in field-effect transistor (FET)/chemiresistor type configuration which is suitable for portable and point-of-use/field-deployable sensors. This review covers the synthesis of carbon nanostructures (graphene and CNTs) and their integration into devices using various fabrication methods. Finally, we discuss the recent reports showing different sensing platforms that incorporate biomolecules like enzymes, antibodies and aptamers as recognition elements for fabrication of simple, low cost, compact biosensors that can be used for on-site, rapid environmental monitoring of environmental pollutants like pathogens, heavy metals, pesticides and explosives.
Collapse
Affiliation(s)
- Pankaj Ramnani
- Department of Chemical and Environmental Engineering, University of California, Riverside, CA 92521, United States
| | - Nuvia M Saucedo
- Department of Chemistry, University of California, Riverside, CA 92521, United States
| | - Ashok Mulchandani
- Department of Chemical and Environmental Engineering, University of California, Riverside, CA 92521, United States.
| |
Collapse
|
8
|
Song XY, Chen J, Shi YP. Electromembrane extraction based on carbon nanotubes reinforced hollow fiber for the determination of plant hormones. NEW J CHEM 2015. [DOI: 10.1039/c5nj01683e] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Under electric field force, negatively charged analytes experienced direct and CNTs-assisted mass transfer from the sample solution to the acceptor phase.
Collapse
Affiliation(s)
- Xin-Yue Song
- Key Laboratory of Chemistry of Northwestern Plant Resources of the CAS and Key Laboratory for Natural Medicine of Gansu Province
- Lanzhou Institute of Chemical Physics
- Chinese Academy of Sciences
- Lanzhou 730000
- People's Republic of China
| | - Juan Chen
- Key Laboratory of Chemistry of Northwestern Plant Resources of the CAS and Key Laboratory for Natural Medicine of Gansu Province
- Lanzhou Institute of Chemical Physics
- Chinese Academy of Sciences
- Lanzhou 730000
- People's Republic of China
| | - Yan-Ping Shi
- Key Laboratory of Chemistry of Northwestern Plant Resources of the CAS and Key Laboratory for Natural Medicine of Gansu Province
- Lanzhou Institute of Chemical Physics
- Chinese Academy of Sciences
- Lanzhou 730000
- People's Republic of China
| |
Collapse
|
9
|
Huang W, Diallo AK, Dailey JL, Besar K, Katz HE. Electrochemical processes and mechanistic aspects of field-effect sensors for biomolecules. JOURNAL OF MATERIALS CHEMISTRY. C 2015; 3:6445-6470. [PMID: 29238595 PMCID: PMC5724786 DOI: 10.1039/c5tc00755k] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Electronic biosensing is a leading technology for determining concentrations of biomolecules. In some cases, the presence of an analyte molecule induces a measured change in current flow, while in other cases, a new potential difference is established. In the particular case of a field effect biosensor, the potential difference is monitored as a change in conductance elsewhere in the device, such as across a film of an underlying semiconductor. Often, the mechanisms that lead to these responses are not specifically determined. Because improved understanding of these mechanisms will lead to improved performance, it is important to highlight those studies where various mechanistic possibilities are investigated. This review explores a range of possible mechanistic contributions to field-effect biosensor signals. First, we define the field-effect biosensor and the chemical interactions that lead to the field effect, followed by a section on theoretical and mechanistic background. We then discuss materials used in field-effect biosensors and approaches to improving signals from field-effect biosensors. We specifically cover the biomolecule interactions that produce local electric fields, structures and processes at interfaces between bioanalyte solutions and electronic materials, semiconductors used in biochemical sensors, dielectric layers used in top-gated sensors, and mechanisms for converting the surface voltage change to higher signal/noise outputs in circuits.
Collapse
Affiliation(s)
- Weiguo Huang
- Department of Materials Science and Engineering, Johns Hopkins University, 3400 North Charles Street, 206 Maryland Hall, Baltimore, MD, USA
| | - Abdou Karim Diallo
- Department of Materials Science and Engineering, Johns Hopkins University, 3400 North Charles Street, 206 Maryland Hall, Baltimore, MD, USA
| | - Jennifer L Dailey
- Department of Materials Science and Engineering, Johns Hopkins University, 3400 North Charles Street, 206 Maryland Hall, Baltimore, MD, USA
| | - Kalpana Besar
- Department of Materials Science and Engineering, Johns Hopkins University, 3400 North Charles Street, 206 Maryland Hall, Baltimore, MD, USA
| | - Howard E Katz
- Department of Materials Science and Engineering, Johns Hopkins University, 3400 North Charles Street, 206 Maryland Hall, Baltimore, MD, USA
| |
Collapse
|
10
|
Tlili C, Badhulika S, Tran TT, Lee I, Mulchandani A. Affinity chemiresistor sensor for sugars. Talanta 2014; 128:473-9. [DOI: 10.1016/j.talanta.2014.05.055] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2014] [Revised: 05/29/2014] [Accepted: 05/29/2014] [Indexed: 11/17/2022]
|
11
|
Singh S, Kaushal A, Khare S, Kumar A. mga genosensor for early detection of human rheumatic heart disease. Appl Biochem Biotechnol 2014; 173:228-38. [PMID: 24639090 DOI: 10.1007/s12010-014-0836-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2014] [Accepted: 02/24/2014] [Indexed: 11/28/2022]
Abstract
The 5' amino-labeled DNA probe complementary to mga gene of Streptococcus pyogenes was immobilized on carboxylated multiwall carbon nanotubes electrode and hybridized with 0.1-100 ng/6 μl single-stranded genomic DNA (ssG-DNA) of S. pyogenes from throat swab of suspected rheumatic heart disease (RHD) patients. Electrochemical response was measured by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance (EI). The sensitivity of the sensor was 106.03 (μA/cm(2))/ng and limit of detection (LOD) was found 0.014 ng/6 μl with regression coefficient (R(2)) of 0.921 using DPV. The genosensor was characterized by FTIR and SEM, and electrode was found stable for 6 months on storage at 4 °C with 5-6 % loss in initial DPV current. mga genosensor is the first report on RHD sensor which can save life of several suspected patients by early diagnosis in 30 min.
Collapse
Affiliation(s)
- Swati Singh
- CSIR-Institute of Genomics and Integrative Biology, Mall Road, Delhi, 110007, India
| | | | | | | |
Collapse
|