1
|
Bertram AM, Conlan XA, van Oorschot RAH, Durdle A. Recovery of DNA from acetaminophen exploring physical state and sampling methods. Forensic Sci Int 2024; 360:112046. [PMID: 38718526 DOI: 10.1016/j.forsciint.2024.112046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 04/15/2024] [Accepted: 04/27/2024] [Indexed: 06/11/2024]
Abstract
Research into the recovery of DNA from illicit drug samples has shown it is possible to get forensically useful profiles from such substrates. However, it is not yet known if the different physical states that drugs can be found in influences the quantity and quality of DNA that can be recovered or what is the best sampling method to adopt for powdered samples. This research used acetaminophen in four different states - large crystalline, powder, in solution, or residue - to determine the efficacy of current DNA technology in recovery and analysis of the resulting sample. Five replicates of each were prepared. Human blood was deposited on or mixed with the drug and left for 1 hour. The surface of the drug was sampled by wet/dry swabbing (where appropriate), or the entire sample was deposited in a tube, and the DNA then extracted using DNA-IQ™. The amount of DNA recovered (ng), degradation index, number of PCR cycles (Ct) required for the IPC to reach threshold, number of alleles in the DNA profile and average peak height (APH) were assessed. All samples, irrespective of the physical state they were collected from, returned full DNA profiles that corresponded to the DNA profile of the blood donor, with no degradation or inhibition detected. It was also found the wet/dry swabbing method returned higher levels of DNA than inclusion of the entire sample into the tube for powdered acetaminophen and the appropriate method to use will be dependent on casework circumstances. The findings of this research further develops our understanding of the recovery of DNA from drugs, and supports the need for further investigation to understand under what conditions DNA can be recovered from illicit substances.
Collapse
Affiliation(s)
- Alexandria M Bertram
- School of Life and Environmental Sciences, Deakin University, Waurn Ponds, VIC 3216, Australia.
| | - Xavier A Conlan
- School of Life and Environmental Sciences, Deakin University, Waurn Ponds, VIC 3216, Australia
| | - Roland A H van Oorschot
- Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, Macleod, VIC 3085, Australia; School of Molecular Sciences, La Trobe University, Bundoora, VIC 3083, Australia
| | - Annalisa Durdle
- School of Life and Environmental Sciences, Deakin University, Waurn Ponds, VIC 3216, Australia
| |
Collapse
|
2
|
Bonsu DNO, Higgins D, Simon C, Henry JM, Austin JJ. Metal-DNA interactions: Exploring the impact of metal ions on key stages of forensic DNA analysis. Electrophoresis 2024; 45:779-793. [PMID: 37638716 DOI: 10.1002/elps.202300070] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 06/15/2023] [Accepted: 08/18/2023] [Indexed: 08/29/2023]
Abstract
Forensic DNA analysis continues to be hampered by the complex interactions between metals and DNA. Metal ions may cause direct DNA damage, inhibit DNA extraction and polymerase chain reaction (PCR) amplification or both. This study evaluated the impact of metal ions on DNA extraction, quantitation, and short tandem repeat profiling using cell-free and cellular (saliva) DNA. Of the 11 metals assessed, brass exhibited the strongest PCR inhibitory effects, for both custom and Quantifiler Trio quantitation assays. Metal ion inhibition varied across the two quantitative PCR assays and the amount of DNA template used. The Quantifiler Trio internal PCR control (IPC) only revealed evidence of PCR inhibition at higher metal ion concentrations, limiting the applicability of IPC as an indicator of the presence of metal inhibitor in a sample. Notably, ferrous ions were found to significantly decrease the extraction efficiency of the DNA-IQ DNA extraction system. The amount of DNA degradation and inhibition in saliva samples caused by metal ions increased with a dilution of the sample, suggesting that the saliva matrix provides protection from metal ion effects.
Collapse
Affiliation(s)
- Dan Nana Osei Bonsu
- Chemistry and Forensic Science, School of Environment and Science, Griffith University, Nathan, Queensland, Australia
- Forensic Research Group, Australian Centre for Ancient DNA (ACAD), School of Biological Sciences, The University of Adelaide, Adelaide, South Australia, Australia
| | - Denice Higgins
- Forensic Research Group, Australian Centre for Ancient DNA (ACAD), School of Biological Sciences, The University of Adelaide, Adelaide, South Australia, Australia
- School of Dentistry, Health and Medical Sciences, The University of Adelaide, Adelaide, South Australia, Australia
| | - Claire Simon
- Forensic Science SA, Attorney-General's Department, Adelaide, South Australia, Australia
| | - Julianne M Henry
- Forensic Science SA, Attorney-General's Department, Adelaide, South Australia, Australia
| | - Jeremy J Austin
- Forensic Research Group, Australian Centre for Ancient DNA (ACAD), School of Biological Sciences, The University of Adelaide, Adelaide, South Australia, Australia
| |
Collapse
|
3
|
Comment D, Gouy A, Zingg C, Zieger M. A holistic approach for the selection of forensic DNA swabs. Forensic Sci Int 2023; 348:111737. [PMID: 37247525 DOI: 10.1016/j.forsciint.2023.111737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 04/04/2023] [Accepted: 05/19/2023] [Indexed: 05/31/2023]
Abstract
In the present study, we compared the performance of five different ISO 18385 certified forensic swabs for DNA sampling in practice over a time period of five months. Comparisons were made for DNA profiling success rates, measured as the percentage of CODIS (Combined DNA Index System) suitable profiles as well as for practical suitability during sampling at the scene, measured through a survey among collaborators. More than forty members of our crime scene investigation (CSI) unit took part in the test series and provided structured feedback concerning different aspects of swab handling. A total number of 1094 "touch" DNA samples have been subjected to DNA analysis. Swabs performed significantly different in terms of DNA profiling success rates. We also observed significant differences in DNA extraction efficiency between swabs. The evaluation by the collaborators of various aspects of handling differed significantly between swabs. We can assume that a more convenient handling decreases the risk of contamination or sample mislabelling and increases sampling efficiency and staff satisfaction. Our results demonstrate that the selection of disposable sampling devices such as forensic swabs for DNA sampling should be made based on a holistic approach. To be able to select the best performing swab for a given combination of CSI and DNA laboratory procedures, it might not be sufficient to only perform DNA extraction comparisons and trace sampling under controlled laboratory conditions.
Collapse
Affiliation(s)
- David Comment
- Forensic section, Cantonal Police Bern, Postcode, 3001 Bern, Switzerland.
| | - Alexandre Gouy
- Institute of Forensic Medicine, University of Bern, Murtenstrasse 26, 3008 Bern, Switzerland; AlgoLife SARL, 87640 Razès, France.
| | - Christian Zingg
- Forensic section, Cantonal Police Bern, Postcode, 3001 Bern, Switzerland.
| | - Martin Zieger
- Institute of Forensic Medicine, University of Bern, Murtenstrasse 26, 3008 Bern, Switzerland.
| |
Collapse
|
4
|
Abdullah A, Szkuta B, Meakin GE. Effect of swabbing technique and duration on forensic DNA recovery. Sci Justice 2023; 63:343-348. [PMID: 37169459 DOI: 10.1016/j.scijus.2023.03.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 02/24/2023] [Accepted: 03/18/2023] [Indexed: 04/03/2023]
Abstract
Various factors have been shown to affect performance of the conventional wet-dry double and single wet swabbing techniques to recover DNA, such as pressure and angle of application, volume and type of wetting agent, and swab type. However, casework laboratories in some jurisdictions have recently adopted different swabbing techniques that include wet-moist double swabbing and moist-dry single swabbing. Factors affecting the effectiveness of these recent techniques in maximising DNA recovery therefore need to be investigated. Here, the performance of traditional and recent swabbing techniques was compared and the impact of swabbing duration on DNA recovery was investigated. Ten µl aliquots of a known concentration of DNA extracted from human blood were deposited on pre-cleaned DNA-free cotton swatches (porous) and porcelain tiles (non-porous). Five swabbing techniques were used, of which three were double swabbing techniques: wet-moist, wet-wet and wet-dry, and two were single swabbing techniques: wet and moist-dry. For a 'wet' or 'moist' swab, 100 or 50 µL water was added, respectively. For a moist-dry swab, water was applied to one side of the swab, leaving the other side drier. Each swabbing technique was applied for two durations, 15 and 30 s per swab, with 5 reps of each combination (n = 100 plus controls). All samples were extracted and quantified, and a sub-set was profiled. The results showed that the wet-moist double swabbing technique with a swabbing duration of 30 s maximised DNA recovery from cotton. From tile, a single wet or moist-dry swab maximised DNA recovery, but increasing swabbing duration from 15 to 30 s had no impact. These data can be used to inform standardisation of DNA collection protocols across casework laboratories.
Collapse
|
5
|
Butler JM. Recent advances in forensic biology and forensic DNA typing: INTERPOL review 2019-2022. Forensic Sci Int Synerg 2022; 6:100311. [PMID: 36618991 PMCID: PMC9813539 DOI: 10.1016/j.fsisyn.2022.100311] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
This review paper covers the forensic-relevant literature in biological sciences from 2019 to 2022 as a part of the 20th INTERPOL International Forensic Science Managers Symposium. Topics reviewed include rapid DNA testing, using law enforcement DNA databases plus investigative genetic genealogy DNA databases along with privacy/ethical issues, forensic biology and body fluid identification, DNA extraction and typing methods, mixture interpretation involving probabilistic genotyping software (PGS), DNA transfer and activity-level evaluations, next-generation sequencing (NGS), DNA phenotyping, lineage markers (Y-chromosome, mitochondrial DNA, X-chromosome), new markers and approaches (microhaplotypes, proteomics, and microbial DNA), kinship analysis and human identification with disaster victim identification (DVI), and non-human DNA testing including wildlife forensics. Available books and review articles are summarized as well as 70 guidance documents to assist in quality control that were published in the past three years by various groups within the United States and around the world.
Collapse
Affiliation(s)
- John M. Butler
- National Institute of Standards and Technology, Special Programs Office, 100 Bureau Drive, Mail Stop 4701, Gaithersburg, MD, USA
| |
Collapse
|
6
|
Evaluation of the Effects of Different Sample Collection Strategies on DNA/RNA Co-Analysis of Forensic Stains. Genes (Basel) 2022; 13:genes13060983. [PMID: 35741745 PMCID: PMC9222428 DOI: 10.3390/genes13060983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 05/18/2022] [Accepted: 05/27/2022] [Indexed: 02/04/2023] Open
Abstract
The aim of this study was to evaluate the impact of different moistening agents (RNase-free water, absolute anhydrous ethanol, RNAlater®) applied to collection swabs on DNA/RNA retrieval and integrity for capillary electrophoresis applications (STR typing, cell type identification by mRNA profiling). Analyses were conducted on whole blood, luminol-treated diluted blood, saliva, semen, and mock skin stains. The effects of swab storage temperature and the time interval between sample collection and DNA/RNA extraction were also investigated. Water provided significantly higher DNA yields than ethanol in whole blood and semen samples, while ethanol and RNAlater® significantly outperformed water in skin samples, with full STR profiles obtained from over 98% of the skin samples collected with either ethanol or RNAlater®, compared to 71% of those collected with water. A significant difference in mRNA profiling success rates was observed in whole blood samples between swabs treated with either ethanol or RNAlater® (100%) and water (37.5%). Longer swab storage times before processing significantly affected mRNA profiling in saliva stains, with the success rate decreasing from 91.7% after 1 day of storage to 25% after 7 days. These results may contribute to the future development of optimal procedures for the collection of different types of biological traces.
Collapse
|
7
|
van Oorschot RAH, Meakin GE, Kokshoorn B, Goray M, Szkuta B. DNA Transfer in Forensic Science: Recent Progress towards Meeting Challenges. Genes (Basel) 2021; 12:genes12111766. [PMID: 34828372 PMCID: PMC8618004 DOI: 10.3390/genes12111766] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 11/04/2021] [Accepted: 11/04/2021] [Indexed: 01/16/2023] Open
Abstract
Understanding the factors that may impact the transfer, persistence, prevalence and recovery of DNA (DNA-TPPR), and the availability of data to assign probabilities to DNA quantities and profile types being obtained given particular scenarios and circumstances, is paramount when performing, and giving guidance on, evaluations of DNA findings given activity level propositions (activity level evaluations). In late 2018 and early 2019, three major reviews were published on aspects of DNA-TPPR, with each advocating the need for further research and other actions to support the conduct of DNA-related activity level evaluations. Here, we look at how challenges are being met, primarily by providing a synopsis of DNA-TPPR-related articles published since the conduct of these reviews and briefly exploring some of the actions taken by industry stakeholders towards addressing identified gaps. Much has been carried out in recent years, and efforts continue, to meet the challenges to continually improve the capacity of forensic experts to provide the guidance sought by the judiciary with respect to the transfer of DNA.
Collapse
Affiliation(s)
- Roland A. H. van Oorschot
- Office of the Chief Forensic Scientist, Victoria Police Forensic Services Department, Macleod, VIC 3085, Australia
- School of Molecular Sciences, La Trobe University, Bundoora, VIC 3086, Australia
- Correspondence:
| | - Georgina E. Meakin
- Centre for Forensic Science, University of Technology Sydney, Ultimo, NSW 2007, Australia;
- Centre for the Forensic Sciences, Department of Security and Crime Science, University College London, London WC1H 9EZ, UK
| | - Bas Kokshoorn
- Netherlands Forensic Institute, 2497 GB The Hague, The Netherlands;
- Faculty of Technology, Amsterdam University of Applied Sciences, 1097 DZ Amsterdam, The Netherlands
| | - Mariya Goray
- College of Science and Engineering, Flinders University, Adelaide, SA 5042, Australia;
| | - Bianca Szkuta
- School of Life and Environmental Sciences, Deakin University, Geelong, VIC 3220, Australia;
| |
Collapse
|
8
|
Comparison of Isohelix™ and Rayon swabbing systems for touch DNA recovery from metal surfaces. Forensic Sci Med Pathol 2021; 17:577-584. [PMID: 34674113 PMCID: PMC8528942 DOI: 10.1007/s12024-021-00423-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/14/2021] [Indexed: 01/11/2023]
Abstract
A previous study evaluating two swabbing systems found that DNA was best recovered from sterile metal substrates using an Isohelix™ swab wetted with isopropyl alcohol rather than a Rayon swab with water as the wetting agent. We tested the same swabbing systems on metal (aluminum, brass, and stainless steel) and plastic substrates in a regularly touched environment to simulate the non-deliberate transfer of touch evidence likely seen in a casework scenario, to ascertain the performance of these swabs in an uncontrolled situation. Higher amounts of touch DNA were recovered with Isohelix™ swabs (0.5 – 3.3 ng) compared to Rayon swabs (0.13 – 1.2 ng). The Isohelix™ swabbing system was found to significantly recover more touch DNA (p = 0.04) from the metal substrates than the Rayon swabbing system, consistent with the findings of our previous work. The results contribute to our understanding of the impact of sample collection techniques on touch DNA recovery from problematic metal surfaces and suggest that supplemental cleaning of substrates as a precautionary step against the spread of infections may affect touch DNA persistence and the recovery efficiency of swabs.
Collapse
|