1
|
Suzuki J, Shiono S, Watanabe H, Sasage T, Hoshijima K, Abe K, Uchida T. Rupture of the staple suture site after stapling the right inferior pulmonary vein with double rows of staples: a case report. GENERAL THORACIC AND CARDIOVASCULAR SURGERY CASES 2025; 4:2. [PMID: 39789659 PMCID: PMC11715081 DOI: 10.1186/s44215-025-00186-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Accepted: 12/18/2024] [Indexed: 01/12/2025]
Abstract
BACKGROUND With advancements in minimally invasive thoracic surgery techniques, such as video-assisted thoracoscopic surgery and robotic surgery, the design of vascular staplers has evolved to meet the requirements of these procedures. Consequently, newer generations of automatic staplers with improved handling and reduced size have been introduced, such as two-row staplers, which are more maneuverable and less bulky than their three-row counterparts. CASE PRESENTATION A 68-year-old man with lung cancer underwent a right middle and lower lobectomy due to tumor invasion into the central middle bronchial trunk, rendering the preservation of the middle lobe impossible. His medical history included chronic atrial fibrillation. The surgery involved a posterolateral incision and a fifth intercostal thoracotomy, where various pulmonary arteries and veins were dissected using vascular staples. Despite completing the surgery without initial complications, the patient experienced significant postoperative bleeding, leading to approximately 800 mL of bloody fluid being drained after coughing episodes. Reoperation was necessary to address and control the bleeding, which was challenging due to the location and nature of the hemorrhage. The source was identified at the transected edge of the inferior pulmonary vein, requiring direct suture after pericardium incision for better access. The total operative time amounted to 751 min, with a blood loss of 2092 mL. The patient recovered smoothly from the second operation and was discharged on the fifth postoperative day. Histopathological examination revealed myocardial cell presence adjacent to the pulmonary vein wall, suggesting that vein thickening could have played a role in the observed postoperative bleeding. CONCLUSIONS In conclusion, when selecting staples for vascular use, particularly for the detachment of pulmonary veins, it is advisable to carefully choose between two-row and three-row staples.
Collapse
Affiliation(s)
- Jun Suzuki
- Department of Surgery II, Faculty of Medicine, Yamagata University, Yamagata, Japan.
| | - Satoshi Shiono
- Department of Surgery II, Faculty of Medicine, Yamagata University, Yamagata, Japan
| | - Hikaru Watanabe
- Department of Surgery II, Faculty of Medicine, Yamagata University, Yamagata, Japan
| | - Takayuki Sasage
- Department of Surgery II, Faculty of Medicine, Yamagata University, Yamagata, Japan
| | - Kazumasa Hoshijima
- Department of Surgery II, Faculty of Medicine, Yamagata University, Yamagata, Japan
| | - Kohei Abe
- Department of Surgery II, Faculty of Medicine, Yamagata University, Yamagata, Japan
| | - Tetsuro Uchida
- Department of Surgery II, Faculty of Medicine, Yamagata University, Yamagata, Japan
| |
Collapse
|
2
|
Khandhar SJ, Desai NP, Anselme S, Shersher DD, Seder CW, Sanchez PG. A real-world study evaluating the safety and utility of a two-row stapler reload on pulmonary vasculature. J Thorac Dis 2024; 16:3753-3763. [PMID: 38983164 PMCID: PMC11228709 DOI: 10.21037/jtd-24-179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Accepted: 05/11/2024] [Indexed: 07/11/2024]
Abstract
Background Endoscopic staplers are common surgical devices used for the ligation and division of vasculature in thoracic procedures. When a stapler ligates and divides pulmonary vasculature, potentially catastrophic intraoperative bleeding at the staple-line may occur. The aim of this study was to confirm the safety and discuss the utility of a two-row stapler reload, by assessing the incidence of clinically necessary intraoperative hemostatic intervention when applied to pulmonary vasculature in real-world applications. Methods This study was designed as a prospective non-comparative registry study conducted in seven centers across the United States, to confirm the safety and performance of Signia™ Small Diameter Reloads (SDR) when used for indicated thoracic surgical procedures. The primary endpoint was the incidence of hemostatic intervention related to the ligation and division of pulmonary arteries and veins. A five-point Likert scale scored hemostasis of each SDR staple-line. Secondary endpoints included the incidence of device-related only adverse events (AEs), device deficiencies, and procedure-related hospital readmission up to and including 30 days post operation. Results SDR was fired 302 times across pulmonary vasculature in 120 subjects. Three firings required clinically necessary hemostatic intervention for an intervention rate of 0.99% (3 of 302 firings). Moreover, 97.5% (117 of 120 subjects) had intact SDR staple-lines regardless of surgical access or stapler handle preference. Only 4 (3.3%) thoracoscopic and robotic procedures converted to open, but none were due to SDR staple-lines. There was no statistically significant difference between the Likert score of transected arteries compared to veins (P=0.61). There were no device deficiencies or device-only related AEs reported. Conclusions In this study, the two-row stapler reloads demonstrated favorable safety and efficacy profiles when fired across hilar vessels in the thoracic space with a 99% hemostatic rate, independent of surgical access and stapler handle preference.
Collapse
Affiliation(s)
- Sandeep J. Khandhar
- Division of Thoracic Surgery, Virginia Cancer Specialists, Inova Fairfax Hospital, Fairfax, VA, USA
| | - Neetha P. Desai
- Clinical Research and Medical Sciences, Medtronic, North Haven, CT, USA
| | | | - David D. Shersher
- Division of Thoracic Surgery, Cooper University Hospital, Camden, NJ, USA
- Division of Thoracic Surgery, Cooper Medical School of Rowan University, Camden, NJ, USA
| | - Christopher W. Seder
- Department of Cardiovascular and Thoracic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Pablo G. Sanchez
- Department of Thoracic Surgery, University of Pittsburgh Physicians, Pittsburgh, PA, USA
| |
Collapse
|
3
|
Guo H, Zheng T, Lin Y, Tang T, Zhang Z, Wang D, Zhao X, Liu Y, Tan B, Yang P, Tian Y, Li Y, Zhao Q. Real-world effectiveness of a new powered stapling system with gripping surface technology on the intraoperative clinical and economic outcomes of gastrectomy for gastric cancer. COST EFFECTIVENESS AND RESOURCE ALLOCATION 2024; 22:38. [PMID: 38711056 DOI: 10.1186/s12962-024-00534-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Accepted: 03/21/2024] [Indexed: 05/08/2024] Open
Abstract
BACKGROUND Surgical staplers have been widely used to facilitate surgeries, and this study aimed to examine the real-world effectiveness of a new powered stapling system with Gripping Surface Technology (GST) on intraoperative outcomes of gastrectomy for gastric cancer. METHOD The data were extracted from the Fourth Hospital of Hebei Medical University's (FHHMU) medical records system. Participants (N = 121 patients) were classified into the GST (n = 59) or non-GST group (n = 62), based on the use of the GST system. The intraoperative outcomes such as bleeding were assessed by reviewing video records. T-tests, Chi-square tests, and Mann-Whitney-U tests were used to compare the baseline characteristics between groups. Multivariate logistic regression was conducted for adjusting outcomes to study the effect of variables. RESULTS Compared with the non-GST group, the GST group had significantly lower risks for intraoperative bleeding, intraoperative anastomosis intervention rate, intraoperative suture, and intraoperative pression (aORs: 0.0853 (p < 0.0001), 0.076 (p = 0.0003), 0.167 (p = 0.0012), and 0.221 (p = 0.0107), respectively). The GST group also consumed one fewer cartridge than the non-GST group (GST:5 vs non-GST: 6, p = 0.0241). CONCLUSION The use of the GST system was associated with better intraoperative outcomes and lower cartridge consumption in Chinese real-world settings.
Collapse
Affiliation(s)
- Honghai Guo
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China
| | - Tao Zheng
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China
| | - Yecheng Lin
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China
| | - Tiange Tang
- Department of Global Health, School of Public Health, New York University, New York, USA
| | - Zhidong Zhang
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China
| | - Dong Wang
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China
| | - Xuefeng Zhao
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China
| | - Yu Liu
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China
| | - Bibo Tan
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China
| | - Peigang Yang
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China
| | - Yuan Tian
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China
| | - Yong Li
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China
| | - Qun Zhao
- Third Department of General Surgery, The Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, People's Republic of China.
| |
Collapse
|
4
|
Al-Attar N, Gaer J, Giordano V, Harris E, Kirk A, Loubani M, Meybohm P, Sayeed R, Stock U, Travers J, Whiteman B. Multidisciplinary paper on patient blood management in cardiothoracic surgery in the UK: perspectives on practice during COVID-19. J Cardiothorac Surg 2023; 18:96. [PMID: 37005650 PMCID: PMC10066978 DOI: 10.1186/s13019-023-02195-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Accepted: 03/29/2023] [Indexed: 04/04/2023] Open
Abstract
The coronavirus (COVID-19) pandemic disrupted all surgical specialties significantly and exerted additional pressures on the overburdened United Kingdom (UK) National Health Service. Healthcare professionals in the UK have had to adapt their practice. In particular, surgeons have faced organisational and technical challenges treating patients who carried higher risks, were more urgent and could not wait for prehabilitation or optimisation before their intervention. Furthermore, there were implications for blood transfusion with uncertain patterns of demand, reductions in donations and loss of crucial staff because of sickness and public health restrictions. Previous guidelines have attempted to address the control of bleeding and its consequences after cardiothoracic surgery, but there have been no targeted recommendations in light of the recent COVID-19 challenges. In this context, and with a focus on the perioperative period, an expert multidisciplinary Task Force reviewed the impact of bleeding in cardiothoracic surgery, explored different aspects of patient blood management with a focus on the use of haemostats as adjuncts to conventional surgical techniques and proposed best practice recommendations in the UK.
Collapse
Affiliation(s)
- Nawwar Al-Attar
- Golden Jubilee National Hospital, University of Glasgow, Agamemnon Street, Clydebank, Glasgow, G81 4DY Scotland, UK
| | - Jullien Gaer
- Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | - Vincenzo Giordano
- Department of Cardiothoracic Surgery, Royal Infirmary Edinburgh, Edinburgh, UK
| | - Emma Harris
- Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | - Alan Kirk
- Department of Thoracic Surgery, Golden Jubilee National Hospital, Glasgow, UK
| | | | - Patrick Meybohm
- Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, University Hospital Wuerzburg, Würzburg, Germany
| | - Rana Sayeed
- Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Ulrich Stock
- Royal Brompton and Harefield NHS Foundation Trust, London, UK
| | - Jennifer Travers
- West of Scotland Cancer Centre, Golden Jubilee National Hospital, Glasgow, UK
| | - Becky Whiteman
- Cluster Medical Manager Advanced Surgery – UKI and Nordics Worldwide Medical, Baxter Healthcare Limited, Berkshire, UK
| |
Collapse
|
5
|
Marra A, Yankulov A. The role of new staplers in reducing the incidence of air leak. J Thorac Dis 2023; 15:893-900. [PMID: 36910065 PMCID: PMC9992581 DOI: 10.21037/jtd-22-192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 07/12/2022] [Indexed: 11/06/2022]
Abstract
Surgical staplers play an important role in the contemporary minimally invasive thoracic surgery including resection of lung tissue. However, staple line failure resulting in postoperative air leaks is a common complication after lung surgery, that if persist more than five days are defined as prolonged air leaks (PALs). PALs are associated with increased length of stay, patient morbidity and mortality, and hospital costs. To reduce the incidence of PALs, stapler devices underwent in the last years ongoing development aimed at improving device-to-tissue interaction. This clinical practice review explores the most important aspects of the evolution of surgical staplers, based on the review of the available literature. Modern staple cartridges entail small bumps to engage tissue and minimize tissue movement during compression and firing. Staplers with graduated staple heights are advocated to generate less stress on tissue during compression and clamping, thus affording greater perfusion into the staple line. However, air leaks may occur from an appropriate staple line with complete pleural coverage and perfusion due to enlarged staple canals after lung inflation, particularly in case of emphysema. To buttress staple line, thus prevent air leaks in high-risk patients, several types of tissue coverage (bovine pericardium, polytetrafluoroethylene, knitted calcium alginate, bioabsorbable polyglycolic acid) have been successfully developed in the last years. Finally, the most advanced stapler technology is represented by the new energy powered staplers, able to eliminate the manual firing force, monitor tissue compression during firing, and making automatic adjustments to optimize the staple line.
Collapse
Affiliation(s)
- Alessandro Marra
- Department of Thoracic Surgery, Lung Centre, Rems-Murr-Klinikum Winnenden, Winnenden/Stuttgart, Germany
| | - Aleksandar Yankulov
- Department of Thoracic Surgery, Lung Centre, Rems-Murr-Klinikum Winnenden, Winnenden/Stuttgart, Germany
| |
Collapse
|
6
|
Gan C, Zeng F, Cong W, Tang T, Feng G. Powered stapling system with gripping surface technology for pulmonary resection of lung cancer: real-world clinical effectiveness. COST EFFECTIVENESS AND RESOURCE ALLOCATION 2022; 20:72. [PMID: 36564821 PMCID: PMC9789598 DOI: 10.1186/s12962-022-00398-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 11/04/2022] [Indexed: 12/24/2022] Open
Abstract
OBJECTIVES Surgical lung resection involves a critical task of stapled ligation and transection of major vascular structures and tissue, which may lead to bleeding and complications. A newer powered stapling system with Gripping Surface Technology (GST) was introduced to account for tissue movements. This study aimed to examine the real-world effectiveness of GST system on intraoperative and postoperative outcomes of pulmonary resection. METHODS A retrospective analysis was conducted using the electronic medical records of Sichuan Provincial People's Hospital between July 2020 and March 2021 in China. Patients who underwent their first procedures of single-port lobectomy or multi-port segmentectomy by video-assisted thoracoscopic surgery were identified and grouped as GST group or manual stapler group (manual group) by the stapler types. The intraoperative outcomes such as bleeding rate, blood loss volume, and intervention rate at the staple line (including intraoperative pressure, suture, and electrocoagulation) were documented by trained nurses during the surgery. Propensity score matching was performed between the two groups, controlling forage, BMI, smoking history, history of surgery, complications, and level of complexity of pneumonectomy. RESULTS A total of 108 matched patients were included in the analysis (54 in the GST group and 54 in the manual group). GST group had lower risks for intraoperative bleeding (22.8% vs 51.9%; p = 0.003) and intraoperative interventions (31.5% vs 55.6%; p = 0.02), compared to the manual group. A decrease in the intraoperative blood loss was observed in the GST group, but not statistically significant (134.39 ± 52.82 ml vs 158.11 ± 73.14 ml, p = 0.102). The use of NEOVEIL (reinforcement material to prevent air leakage from the staple line) intraoperatively during surgery was significantly lower in the GST group (24.1%) than in the manual group (50%, p = 0.01). CONCLUSION The GST system was associated with better intraoperative outcomes in clinical practice in China.
Collapse
Affiliation(s)
- Chongzhi Gan
- grid.410646.10000 0004 1808 0950Department of Thoracic Surgery, Sichuan Provincial People’s Hospital, Chengdu, 610072 Sichuan People’s Republic of China
| | - Fuchun Zeng
- grid.410646.10000 0004 1808 0950Department of Thoracic Surgery, Sichuan Provincial People’s Hospital, Chengdu, 610072 Sichuan People’s Republic of China
| | - Wei Cong
- grid.410646.10000 0004 1808 0950Department of Thoracic Surgery, Sichuan Provincial People’s Hospital, Chengdu, 610072 Sichuan People’s Republic of China
| | - Tiange Tang
- grid.265219.b0000 0001 2217 8588Department of Health Policy and Management, School of Public Health and Tropical Medicine, Tulane University, 1440 Canal St, New Orleans, LA USA
| | - Gang Feng
- grid.410646.10000 0004 1808 0950Department of Thoracic Surgery, Sichuan Provincial People’s Hospital, Chengdu, 610072 Sichuan People’s Republic of China
| |
Collapse
|
7
|
Tomoyasu M, Deguchi H, Kudo S, Shigeeda W, Kaneko Y, Yoshimura R, Kanno H, Saito H. Evaluation of pulmonary artery bleeding during thoracoscopic pulmonary resection for lung cancer. Thorac Cancer 2022; 13:3001-3006. [PMID: 36114752 PMCID: PMC9626345 DOI: 10.1111/1759-7714.14649] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/25/2022] [Accepted: 08/28/2022] [Indexed: 01/07/2023] Open
Abstract
BACKGROUND Bleeding from the pulmonary artery (PA) can be fatal in video-assisted thoracoscopic surgery (VATS) for lung cancer. We evaluated intraoperative PA injury and assessed precautions for thoracoscopic anatomic pulmonary resection. METHODS We retrospectively analyzed a total of 1098 patients who underwent radical surgery for lung cancer utilizing complete VATS from January 2010 to December 2021. RESULTS A total of 16 patients (1.5%) had PA injury during VATS, while hemostasis was performed by conversion to thoracotomy in eight patients (50.0%). Although there was a significantly greater operation time and blood loss for patients in the PA injury group (318.4 vs. 264.9 min, p = 0.001; 550.3 vs. 60.5 g, p ≤ 0.001, respectively), there was no significant different for the chest tube insertion duration and length of postoperative hospital stay (4.9 vs. 7.8 days, p = 0.157; 10.6 vs. 9.9 days, p = 0.136, respectively). There was a significant difference observed for the surgical procedure related to the left upper lobectomy in the PA injury group (43.8 vs. 18.8%, p = 0.012), with the primary causative PA determined to be the left anterior segmental PA (A3 ) (31.3%). CONCLUSIONS VATS is both feasible and safe for lung cancer treatment provided the surgeon performs appropriate hemostasis, although fatal vascular injury could potentially occur during VATS. Surgeons need to be aware of the pitfalls regarding PA dissection management.
Collapse
Affiliation(s)
- Makoto Tomoyasu
- Department of Thoracic Surgery, School of MedicineIwate Medical UniversityYahaba, ShiwaIwateJapan
| | - Hiroyuki Deguchi
- Department of Thoracic Surgery, School of MedicineIwate Medical UniversityYahaba, ShiwaIwateJapan
| | - Satoshi Kudo
- Department of Thoracic Surgery, School of MedicineIwate Medical UniversityYahaba, ShiwaIwateJapan
| | - Wataru Shigeeda
- Department of Thoracic Surgery, School of MedicineIwate Medical UniversityYahaba, ShiwaIwateJapan
| | - Yuka Kaneko
- Department of Thoracic Surgery, School of MedicineIwate Medical UniversityYahaba, ShiwaIwateJapan
| | - Ryuichi Yoshimura
- Department of Thoracic Surgery, School of MedicineIwate Medical UniversityYahaba, ShiwaIwateJapan
| | - Hironaga Kanno
- Department of Thoracic Surgery, School of MedicineIwate Medical UniversityYahaba, ShiwaIwateJapan
| | - Hajime Saito
- Department of Thoracic Surgery, School of MedicineIwate Medical UniversityYahaba, ShiwaIwateJapan
| |
Collapse
|
8
|
Mangiameli G, Cioffi U, Testori A. Lung Cancer Treatment: From Tradition to Innovation. Front Oncol 2022; 12:858242. [PMID: 35692744 PMCID: PMC9184755 DOI: 10.3389/fonc.2022.858242] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Accepted: 04/07/2022] [Indexed: 11/24/2022] Open
Abstract
Lung cancer (LC) is the second most commonly diagnosed cancer and the primary cause of cancer death worldwide in 2020. LC treatment is associated with huge costs for patients and society; consequently, there is an increasing interest in the prevention, early detection with screening, and development of new treatments. Its surgical management accounts for at least 90% of the activity of thoracic surgery departments. Surgery is the treatment of choice for early-stage non-small cell LC. In this article, we discuss the state of the art of thoracic surgery for surgical management of LC. We start by describing the milestones of LC treatment, which are lobectomy and an adequate lymphadenectomy, and then we focus on the traditional and innovative minimally invasive surgical approaches available: video-assisted thoracoscopic surgery (VATS) and robotic-assisted thoracoscopic surgery (RATS). A brief overview of the innovation and future perspective in thoracic surgery will close this mini-review.
Collapse
Affiliation(s)
- Giuseppe Mangiameli
- Division of Thoracic Surgery, IRCCS Humanitas Research Hospital, Milan, Italy
- Department of Biomedical Sciences, Humanitas University, Milan, Italy
| | - Ugo Cioffi
- Department of Surgery, University of Milan, Milan, Italy
| | - Alberto Testori
- Division of Thoracic Surgery, IRCCS Humanitas Research Hospital, Milan, Italy
| |
Collapse
|
9
|
Cao Y, Xiong F, Xia X, Gu P, Wang Q, Wu A, Zhan H, Chen W, Qian Z. Economic impact of powered stapler in video-assisted thoracic surgery lobectomy for lung Cancer in a Chinese tertiary hospital: a cost-minimization analysis. HEALTH ECONOMICS REVIEW 2022; 12:12. [PMID: 35141818 PMCID: PMC8830080 DOI: 10.1186/s13561-022-00359-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Accepted: 02/03/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND To assess the economic impact of powered stapler use in video-assisted thoracic surgery (VATS) lobectomy for lung cancer in a Chinese tertiary care hospital. METHODS This study identified 388 patients who received VATS lobectomy using the ECHELON powered stapler (n = 296) or the ECHELON manual stapler (n = 92) for lung cancer in a Chinese tertiary hospital. Multiple generalized linear regression analyses were conducted using data on hospital costs and patient characteristics to develop predictive equations for hospital costs in a cost-minimization analysis (CMA) model comparing hospital costs associated with the ECHELON powered stapler and the ECHELON manual stapler. CMA model was used to conduct scenario analysis to compare the ECHELON powered stapler with another manual stapler (Victor Medical). RESULTS The multiple generalized linear regression analyses identified that using the ECHELON powered stapler in VATS lobectomy for lung cancer was associated with significantly lower drug costs than using the ECHELON manual stapler (coefficient - 0.256, 95% confidence interval: - 0.375 to - 0.139). The CMA model estimated that the ECHELON powered stapler could save hospital costs by ¥1653 when compared with the ECHELON manual stapler (¥65,531 vs. ¥67,184). The use of the ECHELON powered stapler also saved hospital costs by ¥4411 when compared with the Victor Medical manual stapler (¥65,531 vs. ¥69,942) in the scenario analysis. CONCLUSIONS Compared to the two manual staplers used for VATS lobectomy for lung cancer in a Chinese tertiary hospital, the ECHELON powered stapler had 100% probability to save total hospital costs under present prices of the three staplers according to the CMA.
Collapse
Affiliation(s)
- Yang Cao
- Xiangya Hospital, Central South University, Changsha, China
| | - Fang Xiong
- Xiangya Hospital, Central South University, Changsha, China
| | - Xiaozhe Xia
- Xiangya Hospital, Central South University, Changsha, China
| | - Pengjuan Gu
- Xiangya Hospital, Central South University, Changsha, China
| | - Qinghong Wang
- Xiangya Hospital, Central South University, Changsha, China
| | - Aiping Wu
- Xiangya Hospital, Central South University, Changsha, China
| | - Huan Zhan
- Changsha Normin Health Technology Ltd, Changsha, China
| | | | - Zhaoxin Qian
- Xiangya Hospital, Central South University, Changsha, China.
| |
Collapse
|
10
|
Homma T. Advances and safe use of energy devices in lung cancer surgery. Gan To Kagaku Ryoho 2022; 70:207-218. [PMID: 35107778 PMCID: PMC8881425 DOI: 10.1007/s11748-022-01775-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Accepted: 01/13/2022] [Indexed: 12/12/2022]
Abstract
Objectives A clear understanding of energy devices would help achieve high effectiveness and safety and guide the selection of devices. The present review aimed to elucidate the efficacy and adverse events of energy devices in lung cancer to guide the selection of appropriate devices depending on the situation. Methods Four major databases were searched electronically for relevant articles published until 16 April 2021. The reference lists of the identified papers were examined. We excluded (1) irrelevant studies, (2) manuscripts published in languages other than English and Japanese, (3) duplicates, and (4) studies for which the full text was not available in the databases. The results and key information obtained were summarized by means of a narrative approach. Results A total of 78 papers were included in the review and these were categorized according to the main topic of investigation as follows: (1) electrosurgery-related injuries, (2) fundamentals of electrosurgery, (3) monopolar devices, (4) bipolar electrosurgical devices, (5) ultrasonic energy devices, (6) energy devices in lung cancer surgery, (7) operating room fire risks, and (8) basic principles of surgery. Conclusions Understanding energy devices could help us use them in a more effective and safer manner. Knowledge of their selection criteria (suitability), merits, risks, and safety precautions relevant to each process of lung cancer surgery could guide appropriate selection. Supplementary Information The online version contains supplementary material available at 10.1007/s11748-022-01775-w.
Collapse
Affiliation(s)
- Takahiro Homma
- Department of General Thoracic and Cardiovascular Surgery, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, 2630 Sugitani, Toyama, Toyama, 930-0194, Japan.
| |
Collapse
|
11
|
Madhok B, Nanayakkara K, Mahawar K. Safety considerations in laparoscopic surgery: A narrative review. World J Gastrointest Endosc 2022; 14:1-16. [PMID: 35116095 PMCID: PMC8788169 DOI: 10.4253/wjge.v14.i1.1] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 08/11/2021] [Accepted: 12/10/2021] [Indexed: 02/06/2023] Open
Abstract
Laparoscopic surgery has many advantages over open surgery. At the same time, it is not without its risks. In this review, we discuss steps that could enhance the safety of laparoscopic surgery. Some of the important safety considerations are ruling out pregnancy in women of the childbearing age group; advanced discussion with the patient regarding unexpected intraoperative situations, and ensuring appropriate equipment is available. Important perioperative safety considerations include thromboprophylaxis; antibiotic prophylaxis; patient allergies; proper positioning of the patient, stack, and monitor(s); patient appropriate pneumoperitoneum; ergonomic port placement; use of lowest possible intra-abdominal pressure; use of additional five-millimetre (mm) ports as needed; safe use of energy devices and laparoscopic staplers; low threshold for a second opinion; backing out if unsafe to proceed; avoiding hand-over in the middle of the procedure; ensuring all planned procedures have been performed; inclusion of laparoscopic retrieval bags and specimens in the operating count; avoiding 10-15 mm ports for placement of drains; appropriate port closures; and use of long-acting local anaesthetic agents for analgesia. Important postoperative considerations include adequate analgesia; early ambulation; careful attention to early warning scores; and appropriate discharge advice.
Collapse
Affiliation(s)
- Brij Madhok
- Upper GI Surgery, University Hospitals of Derby and Burton NHS Foundation Trust, Derby DE22 3NE, United Kingdom
| | - Kushan Nanayakkara
- Upper GI Surgery, University Hospitals of Derby and Burton NHS Foundation Trust, Derby DE22 3NE, United Kingdom
| | - Kamal Mahawar
- Department of General Surgery, South Tyneside and Sunderland NHS Foundation Trust, Sunderland SR4 7TP, United Kingdom
| |
Collapse
|
12
|
Clapp B, Schrodt A, Ahmad M, Wicker E, Sharma N, Vivar A, Davis B. Stapler Malfunctions in Bariatric Surgery: An Analysis of the MAUDE Database. JSLS 2022; 26:JSLS.2021.00074. [PMID: 35281706 PMCID: PMC8896815 DOI: 10.4293/jsls.2021.00074] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Background Staple line leaks are a serious problem in bariatric surgery and a major cause of serious morbidity and mortality. Adverse events caused by medical devices are reported to the Food and Drug Administration which maintains the Manufacturer and User Facility Device Experience (MAUDE) database. We examined adverse stapler events reported to the MAUDE database, specifically with regards to bariatric surgery. Methods The MAUDE database was queried for adverse events caused by staplers between January 1, 2018 - December 31, 2020; events reported by Intuitive, Ethicon, and Medtronic/Covidien; and limited our search to "gastric bypass", "sleeve gastrectomy", "stapler malfunction" combined with each company. Results There were 883 adverse events reported for Medtronic, 353 for Ethicon, and 35 for Intuitive. Approximately 3.5 million staple reloads sold in the study period. The reported misfire rate for Medtronic was 0.04% and for Ethicon was 0.02%. Data for Intuitive was unavailable. The most common reported event for Medtronic was failure to fire (n = 349), followed by misfire (n = 186). For Ethicon, the most common event was failure to fire (n = 146), followed by mechanical problems (n = 27). The most common event with the Intuitive stapler was leak (n = 10) and bleeding from staple line (n = 8). Conclusions Stapler malfunction is a very rare event in metabolic and bariatric surgery. All of the major stapler producers have transitioned to powered staplers with excellent safety profiles. Open and honest reporting about stapler malfunction is essential to determine the true safety of these ubiquitous devices.
Collapse
Affiliation(s)
- Benjamin Clapp
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| | - Alexander Schrodt
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| | - Maria Ahmad
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| | - Ellen Wicker
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| | - Nishtha Sharma
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| | - Andres Vivar
- Universidad Autonoma Guadalajara, Guadalajara, Mexico
| | - Brian Davis
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| |
Collapse
|
13
|
Yan T, Zhu S, Zhu M, Zhu K, Dong L, Wang C, Guo C. Clinical Performance of a Powered Surgical Stapler for Left Atrial Appendage Resection in a Video-Assisted Thoracoscopic Ablation for Patients with Nonvalvular Atrial Fibrillation. Int Heart J 2021; 62:764-770. [PMID: 34276010 DOI: 10.1536/ihj.20-765] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Left atrial appendage (LAA) has been found to be associated with the occurrence of thromboembolism in patients with nonvalvular atrial fibrillation (NVAF). Stapling exclusion of LAA during surgical ablation could be an alternative to oral anticoagulation for NVAF patients. However, its safety and efficacy have rarely been examined. Thus, in this study, we aimed to evaluate the safety and efficacy of a powered surgical stapler for LAA resection during ablation for patients with NVAF.Adult patients with NVAF undergoing stapler surgery were included in this study. LAAs of patients were cut off using a powered surgical stapler. Intraoperative transesophageal echocardiogram (TEE) was applied before and after the operation. Each patient received anticoagulant therapy for 2 months after surgery and was regularly followed up by appointment or via telephone call. Patients would undergo physical examinations, echocardiography, and 24-hour dynamic electrocardiogram in a local or in our hospital to determine whether there was a recurrence of atrial fibrillation (AF) or thromboembolism caused by AF.In total, 124 patients were included in this study (male: 88 (71.0%); mean age: 62.3 years). Blood loss was less than 100 mL in all patients with no operative complications or hospital deaths. Moreover, 119 (96.0%) follow-up data were collected, with a mean period of 27.4 months. All patients discontinued oral anticoagulants 2 months after their operation. As per our findings, AF recurred in 23 patients (18.5%), with an average of 9.1 months after surgery. No patients were diagnosed with thromboembolism related to AF.Stapling exclusion of LAA during surgical ablation could safely and completely resect the LAA. The effect of thrombus prevention was deemed satisfactory.
Collapse
Affiliation(s)
- Tao Yan
- Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University
| | - Shijie Zhu
- Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University
| | - Miao Zhu
- Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University
| | - Kai Zhu
- Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University
| | - Lili Dong
- Department of Echocardiography, Zhongshan Hospital, Fudan University
| | - Chunsheng Wang
- Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University
| | - Changfa Guo
- Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University
| |
Collapse
|
14
|
Gao Y, Xiong F, Xia X, Gu P, Wang Q, Wu A, Zhan H, Chen W, Qian Z. Clinical outcomes of powered and manual staplers in video-assisted thoracic surgery lobectomy for lung cancer. J Comp Eff Res 2021; 10:1011-1019. [PMID: 34189927 DOI: 10.2217/cer-2021-0060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Methods: This retrospective cohort study identified patients who underwent video-assisted thoracic surgery (VATS) lobectomy for lung cancer from January 2016 to December 2018 in a Chinese tertiary general hospital. The electronic hospital medical records associated with the VATS lobectomy for lung cancer were the data sources. Results: Based on the analysis of 433 patients with the utilization of staplers in their VATS lobectomy for lung cancer, using powered stapler was associated with significantly shorter operation time and postsurgery hospital stay length than using the manual stapler in the multivariable generalized linear regression analyses with the adjustment of patient characteristics. However, no other significant differences were observed for other clinical outcomes between the two staplers.
Collapse
Affiliation(s)
- Yang Gao
- Department of Thoracic Surgery, Xiangya Hospital, Central South University, Changsha, China
| | - Fang Xiong
- Department of Thoracic Surgery, Xiangya Hospital, Central South University, Changsha, China
| | - Xiaozhe Xia
- Department of Thoracic Surgery, Xiangya Hospital, Central South University, Changsha, China
| | - Pengjuan Gu
- Department of Thoracic Surgery, Xiangya Hospital, Central South University, Changsha, China
| | - Qinghong Wang
- Department of Thoracic Surgery, Xiangya Hospital, Central South University, Changsha, China
| | - Aiping Wu
- Department of Thoracic Surgery, Xiangya Hospital, Central South University, Changsha, China
| | - Huan Zhan
- Changsha Normin Health Technology Ltd, Changsha, China
| | - Wendong Chen
- Normin Health Consulting Ltd, Toronto, L5R 0E9, Canada
| | - Zhaoxin Qian
- Department of Thoracic Surgery, Xiangya Hospital, Central South University, Changsha, China
| |
Collapse
|
15
|
Sylla P, Sagar P, Johnston SS, Dwarakanathan HR, Waggoner JR, Schwiers M, Roy S. Outcomes associated with the use of a new powered circular stapler for left-sided colorectal reconstructions: a propensity score matching-adjusted indirect comparison with manual circular staplers. Surg Endosc 2021; 36:2541-2553. [PMID: 34031743 PMCID: PMC8921098 DOI: 10.1007/s00464-021-08542-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Accepted: 05/04/2021] [Indexed: 12/17/2022]
Abstract
Background This was a retrospective, matching-adjusted indirect comparison of clinical outcomes between patients from a single-arm trial of the ECHELON CIRCULAR™ Powered Stapler (ECP) and those from a historical cohort of patients who underwent left-sided colorectal resection using conventional manual circular staplers, extracted from the Premier Healthcare Database. Methods Patients in the ECP trial cohort were propensity score matched to those in the historical cohort through nearest neighbor matching. Outcomes included 30-day readmission rates; length of stay (LOS) for the index admission; rates of anastomotic leak, pelvic abscess, ileus/small bowel obstruction, infection, bleeding, and stoma creation. Results The study included 168 patients in the ECP trial cohort and 4544 patients in the historical cohort; 165 ECP trial patients were matched to 1348 historical cohort patients. After matching, conversions were more prevalent in the historical cohort than the ECP trial cohort (4.2% ECP vs. 10.2% historical, p = 0.001). Relative to the historical cohort, the ECP trial cohort had statistically significant lower rates of 30-day inpatient readmission (6.1% vs. 10.8%, p = 0.019), anastomotic leak (1.8% vs. 6.9%, p < 0.001), ileus/small bowel obstruction (4.8% vs. 14.7%, p < 0.001), infection (1.8% vs. 5.7%, p = 0.001), and bleeding (1.8% vs. 9.2%, p < 0.001) during the index admission or within 30 days thereafter. No statistically significant differences in rates of pelvic abscess, stoma creation, or LOS were found between the two cohorts. Three sensitivity analyses to address the difference in conversion rates yielded largely consistent results, with loss of statistical significance for inpatient admission in some cases. This study is limited by its potential for differences in unmeasurable factors between the ECP trial and historical cohorts. Conclusions In this study, the ECP trial cohort had lower incidence proportions of several surgical complications as compared with the historical cohort. Further controlled prospective clinical studies are needed to confirm the validity of this finding. Supplementary Information The online version contains supplementary material available at 10.1007/s00464-021-08542-7.
Collapse
Affiliation(s)
- Patricia Sylla
- Division of Colon and Rectal Surgery, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Peter Sagar
- John Goligher Colorectal Department, St James' University Hospital, Leeds, UK
| | - Stephen S Johnston
- Real-World Data Analytics and Research, Epidemiology, Medical Devices, Johnson & Johnson, 410 George Street, New Brunswick, NJ, USA.
| | | | | | | | - Sanjoy Roy
- Ethicon Endo-Surgery, Inc, Cincinnati, OH, USA
| |
Collapse
|
16
|
Wang H, Ge W, Liu C, Wang P, Song C. Design and performance evaluation of a powered stapler for gastrointestinal anastomosis. MINIM INVASIV THER 2021; 31:595-602. [PMID: 33412971 DOI: 10.1080/13645706.2020.1867585] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
OBJECTIVE This paper reports the design of a powered stapler for gastrointestinal anastomosis and evaluates its performance. The proposed stapling instrument is intended to simplify and optimize the current procedure of mechanical stapling, while providing controllable operation for the powered stapling procedure, such as conditioning the tissue to the right stage before firing of the stapler. MATERIAL AND METHODS The feasibility and efficacy of the prototype were assessed by ex vivo experiments with porcine small intestine segments, where the tissue conditioning operation, burst pressure of the stapled intestine samples, and staple malformation rate were examined. RESULTS The functionality of the developed powered stapler was validated, where the theoretical, numerical, and experimental results agree well with each other. The preliminary results indicated that the proposed tissue conditioning operation could lower the clamping pressure with a maximum level of 1.35 g/mm2. The average burst pressure of the stapled segments (16 samples) is 6.37 kPa, and the maximum malformation rate of the tested groups (five groups, each group with 90 staplers) was 5.56%. CONCLUSION The developed novel tissue conditioning procedure could reduce the pressure response of the intestine tissue samples. The proposed powered stapler proves effective for performing gastrointestinal anastomosis procedures.
Collapse
Affiliation(s)
- Haochen Wang
- Shanghai Institute for Minimally Invasive Therapy, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Wenming Ge
- Shanghai Institute for Minimally Invasive Therapy, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Chenxu Liu
- Shanghai Institute for Minimally Invasive Therapy, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Peiyao Wang
- Shanghai Institute for Minimally Invasive Therapy, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China
| | - Chengli Song
- Shanghai Institute for Minimally Invasive Therapy, School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China
| |
Collapse
|
17
|
Fortin SP, Johnston SS, Chaudhuri R, Fryrear R, Roy S. Incidence, predictors, and economic burden of circular anastomotic complications in left-sided colorectal reconstructions involving manual circular staplers. J Med Econ 2021; 24:255-265. [PMID: 33576292 DOI: 10.1080/13696998.2021.1880749] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
STUDY AIM Manual circular staplers are widely used in colorectal surgery; however, limited literature exists examining complications related to circular anastomoses when such devices are used. The present study evaluated the incidence, predictors, and economic burden of circular anastomotic complications in left-sided colorectal reconstructions involving manual circular staplers. MATERIALS AND METHODS Patients aged ≥18 years who underwent hemicolectomy, low anterior resection, or sigmoidectomy between 1 October 2016 and 31 December 2018 were identified from the Premier Healthcare Database. Manual circular stapler use was identified from hospital administrative billing records. Circular anastomotic complications were defined as a composite endpoint of multiple circular stapler use (proxy for stapler failure) or other circular anastomotic complications (anastomotic leak, bleeding, device/surgical complications, infection, and transfusion). Multivariable analyses were used to model the associations between circular anastomotic complications and total hospital costs, length of stay, operating room time, and 30-, 60-, and 90-day readmission rates. RESULTS A total of 13,167 patients met the study criteria, of whom 2,984 (22.7%) had circular anastomotic complications. Predictors of circular anastomotic complications included age, procedure type, provider region, and select patient comorbidities. As compared with those who did not, patients who suffered circular anastomotic complications had significantly higher adjusted total hospital costs ($26,924 vs. $18,748; p < .0001), length of stay (7.79 vs. 4.99 days; p < .0001), operating room time (280 vs. 239 min; p < .0001), non-home discharge status (9.63% vs. 4.61%; p < .0001), and all-cause readmission at 30 days (12.2% vs. 8.7%; p < .0001), 60 days (16.0% vs. 11.6%; p < .0001), and 90 days (18.5% vs. 13.4%; p < .0001). LIMITATIONS The present study is limited by the observational nature and potential for measurement error that is inherent to administrative healthcare databases. CONCLUSIONS In this analysis of patients undergoing left-sided colorectal reconstructions involving a manual circular stapler, circular anastomotic complications were associated with adverse economic consequences.
Collapse
Affiliation(s)
- Stephen P Fortin
- Medical Devices - Epidemiology, Johnson & Johnson Co., New Brunswick, NJ, USA
| | - Stephen S Johnston
- Medical Devices - Epidemiology, Johnson & Johnson Co., New Brunswick, NJ, USA
| | | | - Raymond Fryrear
- Preclinical, Clinical, Medical Centre, Ethicon Inc., Cincinnati, OH, USA
| | - Sanjoy Roy
- Franchise Health Economics and Market Access, Ethicon Inc., Cincinnati, OH, USA
| |
Collapse
|
18
|
Utility of the powered stapler for radical pulmonary resection: a propensity score-matched analysis. Surg Today 2020; 51:582-588. [PMID: 33037476 DOI: 10.1007/s00595-020-02154-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 08/13/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE Anatomical pulmonary resection, such as lobectomy, is a common procedure. Staplers play an important role in dividing an incomplete interlobular fissure, especially in thoracoscopic surgery. This study evaluates the effectiveness of a powered stapler for reducing the need for intraoperative fibrin glue and the incidence of air leakage after radical pulmonary resection. METHODS The subjects of this retrospective study were 478 patients who underwent radical pulmonary resection. Propensity score analysis generated two matched pairs of 177 patients treated using powered and manual staplers, respectively. RESULTS The need for fibrin glue intraoperatively during radical pulmonary resection was significantly less in the powered-stapler group (47.5%) than in the manual-stapler group (58.8%, p = 0.033). The incidence of postoperative air leakage following radical pulmonary resection was also significantly lower in the powered-stapler group (2.8%) than in the manual-stapler group (10.7%, p = 0.003). Logistic regression analysis identified use of the powered stapler as a factor independently associated with both non-use of fibrin glue intraoperatively (odds ratio, 0.63; p = 0.040) and no postoperative air leakage (odds ratio, 0.26; p = 0.010). CONCLUSION Using a powered stapler to divide the incomplete interlobular fissure decreased the need for additional intraoperative management using fibrin glue and reduced postoperative air leakage in radical pulmonary resection.
Collapse
|
19
|
Evaluation of a Powered Vascular Stapler in Video-Assisted Thoracic Surgery Lobectomy. J Surg Res 2020; 253:26-33. [DOI: 10.1016/j.jss.2020.03.023] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 01/24/2020] [Accepted: 03/09/2020] [Indexed: 11/22/2022]
|
20
|
Rawlins L, Johnson BH, Johnston SS, Elangovanraaj N, Bhandari M, Cohen RV, Rheinwalt KP, Fryrear R, Roy S. Comparative Effectiveness Assessment of Two Powered Surgical Stapling Platforms in Laparoscopic Sleeve Gastrectomy: A Retrospective Matched Study. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2020; 13:195-204. [PMID: 32765125 PMCID: PMC7368239 DOI: 10.2147/mder.s256237] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 06/04/2020] [Indexed: 11/23/2022] Open
Abstract
Objective To compare outcomes between the two latest innovations in powered stapling technology, the ECHELON FLEX™ GST system (GST) and the Signia™ Stapling System (SIG), among patients undergoing sleeve gastrectomy for obesity. Patients and Methods Using the Premier Healthcare Database of US hospital discharge records, we selected patients undergoing inpatient sleeve gastrectomy with dates of surgical admission between March 1, 2017 (SIG launch), and December 31, 2018. Outcomes measured during the surgical admission included in-hospital hemostasis-related complications (bleeding/transfusion; primary outcome), leak, total hospital costs, length of stay (LOS), and operating room time; 30-, 60-, and 90-day all-cause inpatient readmissions were also examined. We used 1:1 cardinality matching to balance the GST and SIG groups on numerous patient and hospital/provider characteristics, allowing a maximum standardized mean difference (SMD) ≤0.05 for all matching covariates. Generalized estimating equations (GEE) accounting for hospital-level clustering were used to compare the study outcomes between the GST and SIG groups. Results Of the 5573 identified cases, there were 491 patients in each group (982 total) after matching. The observed incidence proportion of hemostasis-related complications during the surgical admission was lower in the GST group as compared with the SIG group (3 events/491 [0.61%] vs 11 events/491 [2.24%]; odds ratio [SIG=reference] = 0.28, 95% CI=0.13–0.60, P=0.0012). Differences between the GST and SIG groups were not statistically significant for leak, total hospital costs, LOS, OR time, and all-cause inpatient readmission at 30, 60, and 90 days. Conclusion In this retrospective study of 982 matched patients undergoing sleeve gastrectomy, the ECHELON FLEX™ GST system was associated with a lower rate of hemostasis-related complications as compared with the Signia™ Stapling System. Further controlled prospective studies are needed to confirm the validity of this finding.
Collapse
Affiliation(s)
- Logan Rawlins
- Allegheny Health Network Bariatric & Metabolic Institute, Pittsburgh, PA, USA
| | | | | | | | - Mohit Bhandari
- Mohak Bariatric and Robotic Surgery Centre, Indore, India
| | - Ricardo V Cohen
- The Center for the Treatment of Obesity and Diabetes, Hospital Alemão Oswaldo Cruz, Sao Paulo, Brazil
| | | | - Raymond Fryrear
- Johnson & Johnson Medical Device Company, Cincinnati, OH, USA
| | - Sanjoy Roy
- Johnson & Johnson Medical Device Company, Cincinnati, OH, USA
| |
Collapse
|
21
|
Atallah S, Kural S, Banda N, Banda A, Bawaney F, Cabral F, Neychev V, Patel C, Larach S. Initial clinical experience with a powered circular stapler for colorectal anastomosis. Tech Coloproctol 2020; 24:479-486. [PMID: 32193667 DOI: 10.1007/s10151-020-02162-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2020] [Accepted: 02/05/2020] [Indexed: 11/26/2022]
Abstract
BACKGROUND The Echelon circular™ powered stapler (ECP stapler) obviates the need for manual firing of conventional circular staplers during the construction of a colorectal anastomosis, but has not been evaluated clinically. The aim of this study was to perform a clinical evaluation of this stapler. METHODS A retrospective review of the initial clinical experience of a single surgeon using the ECP stapler for left-sided colorectal anastomosis construction during elective colorectal resections for benign and malignant disease was conducted by analyzing results from a prospectively maintained study database. Additionally, four attending colorectal and/or general surgeons who had performed ≥ 5 colorectal operations with the ECP stapler were invited to complete an anonymous online survey to subjectively assess the user experience with the device. Statistical analysis was conducted using Microsoft Excel Version 15.33. RESULTS Seventeen patients underwent left-sided anastomotic reconstruction using the ECP stapler. All donuts (proximal and distal) were intact. Anastomotic integrity was evaluated using the air-leak test utilizing flexible video sigmoidoscopy. No leaks were observed, although one patient (5.9%) developed a postoperative pelvic abscess. The anonymous survey was completed by all four surgeons. Subjective evaluation of the ECP stapler suggests that the overall stapling quality, overall device ease-of-use, and the overall perception of anastomotic quality as above average when compared to manual 'end-to-end anastomosis' (EEA) stapling devices. CONCLUSIONS In an initial clinical evaluation of the ECP stapler, the safety and ease-of-use of the device appears to be satisfactory. Powered stapling and the design of '3D stapling' may provide advantages over manual systems, and may improve the construction quality of left-sided colorectal anastomosis.
Collapse
Affiliation(s)
- S Atallah
- University of Central Florida, College of Medicine, Orlando, FL, USA.
- HCA North Florida Division, Winter Park, FL, 32792, USA.
| | - S Kural
- Uludag University, Bursa, Turkey
| | - N Banda
- University of Central Florida, College of Medicine, Orlando, FL, USA
| | - A Banda
- University of Central Florida, College of Medicine, Orlando, FL, USA
| | - F Bawaney
- University of Central Florida, College of Medicine, Orlando, FL, USA
| | - F Cabral
- Instituto Português de Oncologia, Lisbon, Portugal
| | - V Neychev
- University of Central Florida, College of Medicine, Orlando, FL, USA
- HCA North Florida Division, Winter Park, FL, 32792, USA
| | - C Patel
- University of Central Florida, College of Medicine, Orlando, FL, USA
- HCA North Florida Division, Winter Park, FL, 32792, USA
| | - S Larach
- University of Central Florida, College of Medicine, Orlando, FL, USA
- HCA North Florida Division, Winter Park, FL, 32792, USA
| |
Collapse
|
22
|
Tsunezuka Y, Tanaka N, Fujimori H. The Impact of Endoscopic Stapler Selection on Bleeding at the Vascular Stump in Pulmonary Artery Transection. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2020; 13:41-47. [PMID: 32104107 PMCID: PMC7024768 DOI: 10.2147/mder.s240343] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 01/24/2020] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVE To assess bleeding following transection of the pulmonary artery with powered and manual endoscopic staplers. METHODS Cases of video-assisted and open-chest thoracic surgical procedures for non-small cell lung cancer at Ishikawa Prefectural Central Hospital were reviewed between 2012 and 2018. Three stapler groups were assessed: Group 1 - Ethicon ECHELON FLEXTM Powered Vascular Stapler (PVS), Group 2 - Medtronic Endo-GIATM iDriveTM powered stapler, Group 3 - Ethicon and Medtronic manual staplers. RESULTS Of 239 patients, 82 cases (34.3%) were Group 1, 94 cases (39.3%) were Group 2 and 63 cases (26.4%) were Group 3. Mean age was 68.3 years (range 36-88 years), and most patients received video-assisted right upper lobectomy (82.8%). Bleeding occurred in 24 cases: 17 (70.8%) in Group 2 and 7 (29.2%) cases in Group 3. No bleeding occurred in Group 1. The loaded ECHELON FLEXTM PVS and Endo-GIATM iDriveTM with gray cartridge combinations had the greatest and smallest closed anvil jaw gaps (>0.63 µm and <0.15 µm, respectively); Endo-GIATM iDriveTM gray cartridge combinations resulted in ruptures of inner and middle membranes of the pulmonary artery. No ruptures were observed using the ECHELON FLEXTM PVS. CONCLUSION An excessively narrow gap between cartridge and anvil may damage the blood vessel wall and lead to bleeding following transection. This study provides preliminary evidence that the use of the ECHELON FLEXTM PVS and tan cartridges for pulmonary artery stapling may help to prevent tissue damage and intraoperative bleeding.
Collapse
Affiliation(s)
- Yoshio Tsunezuka
- Department of General Thoracic Surgery, Ishikawa Prefectural Central Hospital, Kanazawa, Japan
| | - Nobuhiro Tanaka
- Department of General Thoracic Surgery, Ishikawa Prefectural Central Hospital, Kanazawa, Japan
| | - Hideki Fujimori
- Department of General Thoracic Surgery, Ishikawa Prefectural Central Hospital, Kanazawa, Japan
| |
Collapse
|
23
|
Park SY, Kim DJ, Mo Nam C, Park G, Byun G, Park H, Choi JH. Clinical and economic benefits associated with the use of powered and tissue-specific endoscopic staplers among the patients undergoing thoracoscopic lobectomy for lung cancer. J Med Econ 2019; 22:1274-1280. [PMID: 31210074 DOI: 10.1080/13696998.2019.1634081] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Background: Thoracoscopic lobectomy for lung cancer is a complex procedure where endoscopic staplers play a critical role in transecting the lung parenchyme, vasculature, and bronchus. This retrospective study was performed to investigate the economic benefits of powered and tissue-specific endoscopic staplers such as gripping surface technology (GST) and powered vascular stapler (PVS) compared to standard staplers.Methods: Two hundred and seventy-five patients who received a thoracoscopic lobectomy between 2008 and 2016 were included. Group 1 (n = 117) consisted of patients who received the operation with manual endoscopic staplers, whereas Group 2 (n = 158) consisted of patients who received the operation with GST and PVS.Results: Patient demographics and clinical characteristics were comparable, except smoking history, pulmonary function, and pleural adhesion. All patients received the operation successfully without mortalities and broncho-pleural fistula. Operation time and blood loss were higher in Group 1. Pleurodesis was performed less in Group 2 than in Group 1 (18.0% vs 3.8%, p < 0.0001). Group 2 had statistically significant lower adjusted hospital costs (Korean Won, 14,610,162 ± 4,386,628 vs 12,876,111 ± 5,010,878, p < 0.0001), lower adjusted hemostasis related costs (198,996 ± 110,253 vs 175,291 ± 191,003, p = 0.0101); lower cartridge related adjusted costs (1,105,091 ± 489,838 vs 839,011 ± 307,894, p < 0.0001) compared to Group 1. As well, Group 2 showed ∼12% lower adjusted total hospital costs compared to Group 1. Multivariable analysis revealed that Group 1 was related to increased hospital costs.Conclusions: This study showed that thoracoscopic lobectomy with powered and tissue-specific endoscopic staplers were associated with better clinical outcomes and reduced adjusted hospital costs when compared in Korean real-world settings.
Collapse
Affiliation(s)
- Seong Yong Park
- Department of Thoracic and Cardiovascular Surgery, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Dae Joon Kim
- Department of Thoracic and Cardiovascular Surgery, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Chung Mo Nam
- Department of Preventive Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Goeun Park
- Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Goeun Byun
- Department of Thoracic and Cardiovascular Surgery, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - HyeJin Park
- HEMA, Johnson & Johnson Medical Korea, Seoul, Republic of Korea
| | - Ji Heon Choi
- HEMA, Johnson & Johnson Medical Korea, Seoul, Republic of Korea
| |
Collapse
|
24
|
Qiu B, Kang X, Chen KN, Hu J, Li J, Zeng L, Fegelman EJ, Schwiers ML, Creedon EE, Waggoner JR, Ding D, Yang T, Gao S. Clinical outcomes following an initial experience with a novel powered vascular stapler in video-assisted thoracoscopic lobectomies: results of a Chinese multi-center study. J Thorac Dis 2019; 11:1973-1979. [PMID: 31285890 DOI: 10.21037/jtd.2019.04.89] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Background The development of minimally invasive surgical approaches has revolutionized surgical care and greatly improved surgical outcomes. This study aimed to evaluate the clinical effectiveness of a powered vascular stapler (PVS) during video-assisted thoracoscopic surgery (VATS) lobectomy. Methods This prospective, multi-center, post-market clinical study in China enrolled 50 patients with either a suspected or formal diagnosis of clinical stage IA to IIB non-small cell lung cancer (NSCLC) scheduled for VATS lobectomy. The clinical effectiveness of the PVS for successful pulmonary artery (PA)/pulmonary vein (PV) transection was evaluated. In addition, the surgeon's stress, device usability, and surgeon satisfaction were measured using multiple questionnaires. Results A total of 167 PAs/PVs were transected with 3 (1.8%) requiring intra-operative intervention. Fourteen of the 50 patients (28.0%) experienced at least one adverse event (AE), among whom 5 (10.0%) suffered from serious AEs. There were no postoperative hemorrhagic complications related to transection of the PA/PV with PVS. Surgeon satisfaction was surveyed by questionnaire after each of the 50 procedures resulting in a 96% reported satisfaction with device usability, specifically related to a low stress load and an increase in work efficiency. Conclusions For VATS lobectomy, the PVS demonstrated a positive surgical effectiveness and value in cognitive and physical distress reduction. Complications following VATS lobectomy to treat NSCLC were generally low and as expected. Intraoperative complications were few and there were no postoperative complications related to the transection of the PA and PV during VATS lobectomy. Favorable results were reported on the surgeon satisfaction questionnaire regarding usability and surgeon stress.
Collapse
Affiliation(s)
- Bin Qiu
- Department of Thoracic Surgery, Cancer Hospital, Chinese Academy of Medical Sciences, Beijing 100021, China
| | - Xiaozheng Kang
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), the First Department of Thoracic Surgery, Peking University Cancer Hospital & Institute, Beijing 100142, China
| | - Ke-Neng Chen
- Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), the First Department of Thoracic Surgery, Peking University Cancer Hospital & Institute, Beijing 100142, China
| | - Jian Hu
- Department of Thoracic Surgery, the First Affiliated Hospital, Zhejiang University, Hangzhou 310003, China
| | - Jian Li
- Department of Thoracic Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
| | - Liping Zeng
- Department of Thoracic Surgery, the First Affiliated Hospital, Zhejiang University, Hangzhou 310003, China
| | | | | | | | | | - Ding Ding
- Johnson & Johnson Medical (Shanghai) LTD, Shanghai 200233, China
| | - Tengfei Yang
- Johnson & Johnson Medical (Shanghai) LTD, Shanghai 200233, China
| | - Shugeng Gao
- Department of Thoracic Surgery, Cancer Hospital, Chinese Academy of Medical Sciences, Beijing 100021, China
| |
Collapse
|
25
|
Kawai H. Problems with using the air leak test with Yang's bubble solution during video-assisted thoracic surgery. J Thorac Dis 2019; 11:630-631. [PMID: 31019744 DOI: 10.21037/jtd.2019.02.44] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Hideki Kawai
- Department of Thoracic Surgery, Akita Red Cross Hospital, Akita, Japan
| |
Collapse
|
26
|
Roy S. Lung cancer: new tools for surgery. Lung Cancer Manag 2018; 7:LMT03. [PMID: 30713585 PMCID: PMC6356146 DOI: 10.2217/lmt-2018-0011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Accepted: 08/22/2018] [Indexed: 11/21/2022] Open
Abstract
Sanjoy Roy speaks to Alfie Gleeson, Commissioning Editor: Sanjoy Roy is the Director of Franchise Health Economics and Market Access at Ethicon, Inc. – part of the Johnson and Johnson Medical Device Companies (OH, USA). He has a Bachelor's degree in Pharmacy from Jadavpur University (West Bengal, India), a Master's degree in Health Outcomes and Policy from West Virginia University (WV, USA) and a Professional Certificate in Strategic Marketing from Harvard University (MA, USA). He is a health economist and outcomes researcher with over two decades of work experience in the pharmaceutical and medical devices industry – both in commercial and in research functions. Ethicon has been making significant contributions to surgery, particularly in the suture field, for over 60 years. From the first sutures to the development of minimally invasive procedures they have revolutionized surgery more than once. Sanjoy Roy talks to Lung Cancer Management about how Ethicon has shaped surgery, and how new tools that Ethicon has developed have improved lung cancer surgery outcomes and reduced the economic burden of lung cancer treatment. Finally, we look at the future of lung cancer surgery and how it may change in the light of new technologies and the global burden of disease and healthcare costs.
Collapse
Affiliation(s)
- Sanjoy Roy
- Ethicon/Johnson & Johnson Medical Devices, Cincinnati, OH, USA
| |
Collapse
|