1
|
Chen X, Zhou B, Guo X, Xie H, Liu Q, Duncan JS, Sinusas AJ, Liu C. DuDoCFNet: Dual-Domain Coarse-to-Fine Progressive Network for Simultaneous Denoising, Limited-View Reconstruction, and Attenuation Correction of Cardiac SPECT. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:3110-3125. [PMID: 38578853 DOI: 10.1109/tmi.2024.3385650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/07/2024]
Abstract
Single-Photon Emission Computed Tomography (SPECT) is widely applied for the diagnosis of coronary artery diseases. Low-dose (LD) SPECT aims to minimize radiation exposure but leads to increased image noise. Limited-view (LV) SPECT, such as the latest GE MyoSPECT ES system, enables accelerated scanning and reduces hardware expenses but degrades reconstruction accuracy. Additionally, Computed Tomography (CT) is commonly used to derive attenuation maps ( μ -maps) for attenuation correction (AC) of cardiac SPECT, but it will introduce additional radiation exposure and SPECT-CT misalignments. Although various methods have been developed to solely focus on LD denoising, LV reconstruction, or CT-free AC in SPECT, the solution for simultaneously addressing these tasks remains challenging and under-explored. Furthermore, it is essential to explore the potential of fusing cross-domain and cross-modality information across these interrelated tasks to further enhance the accuracy of each task. Thus, we propose a Dual-Domain Coarse-to-Fine Progressive Network (DuDoCFNet), a multi-task learning method for simultaneous LD denoising, LV reconstruction, and CT-free μ -map generation of cardiac SPECT. Paired dual-domain networks in DuDoCFNet are cascaded using a multi-layer fusion mechanism for cross-domain and cross-modality feature fusion. Two-stage progressive learning strategies are applied in both projection and image domains to achieve coarse-to-fine estimations of SPECT projections and CT-derived μ -maps. Our experiments demonstrate DuDoCFNet's superior accuracy in estimating projections, generating μ -maps, and AC reconstructions compared to existing single- or multi-task learning methods, under various iterations and LD levels. The source code of this work is available at https://github.com/XiongchaoChen/DuDoCFNet-MultiTask.
Collapse
|
2
|
Ichikawa H, Kato T, Kondo H, Shimada H, Shibutani T, Onoguchi M. Efficacy of a Novel Respiratory Motion Reduction Block in Reducing Motion Artifact on Myocardial Perfusion Single-Photon Emission Computed Tomography. Cureus 2024; 16:e60656. [PMID: 38899261 PMCID: PMC11186179 DOI: 10.7759/cureus.60656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/20/2024] [Indexed: 06/21/2024] Open
Abstract
PURPOSE Motion artifacts caused by heart motion during myocardial perfusion single-photon emission computed tomography (SPECT) can compromise image quality and diagnostic accuracy. This study aimed to evaluate the efficacy of the novel respiratory motion reduction block (RRB) device in reducing motion artifacts by compressing the hypochondrium and improving SPECT image quality. METHODS In total, 91 patients who underwent myocardial perfusion SPECT with 99mTc-sestamibi were retrospectively analyzed. Patients (n = 28) who underwent SPECT without the RRB were included in the control group, and those (n = 63) who underwent SPECT with the RRB were in the RRB group. The distance of heart motion during dynamic acquisition was measured, and projection data were assessed for patient motion and motion artifacts. Patient motion was classified into various levels, and motion artifacts on SPECT images were visually examined. RESULTS The distances of heart motion without and with the RRB were 15.4 ± 5.3 and 7.5 ± 2.3, respectively. Compared with the control group, the RRB group had a lower frequency of heart motion based on the projection data, particularly in terms of creep and shift motion. The RRB group had a significantly lower incidence of motion artifacts on SPECT images than the control group. CONCLUSIONS The RRB substantially reduced specific types of motion, such as shift and creep, and had a low influence on bounce motion. However, it could effectively suppress respiratory-induced heart motion and reduce motion artifacts on myocardial perfusion SPECT, thereby emphasizing its potential for improving image quality.
Collapse
Affiliation(s)
- Hajime Ichikawa
- Department of Radiology, Toyohashi Municipal Hospital, Toyohashi, JPN
- Department of Quantum Medical Technology, Kanazawa University, Kanazawa, JPN
| | - Toyohiro Kato
- Department of Radiology, Toyohashi Municipal Hospital, Toyohashi, JPN
| | - Hiroki Kondo
- Department of Cardiology, Nagoya University Hospital, Nagoya, JPN
| | - Hideki Shimada
- Department of Radiology, Toyohashi Municipal Hospital, Toyohashi, JPN
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Kanazawa University, Kanazawa, JPN
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Kanazawa University, Kanazawa, JPN
| |
Collapse
|
3
|
Ko CL, Lin SS, Huang CW, Chang YH, Ko KY, Cheng MF, Wang SY, Chen CM, Wu YW. Polar map-free 3D deep learning algorithm to predict obstructive coronary artery disease with myocardial perfusion CZT-SPECT. Eur J Nucl Med Mol Imaging 2023; 50:376-386. [PMID: 36102963 DOI: 10.1007/s00259-022-05953-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 08/23/2022] [Indexed: 01/10/2023]
Abstract
PURPOSE Deep learning (DL) models have been shown to outperform total perfusion deficit (TPD) quantification in predicting obstructive coronary artery disease (CAD) from myocardial perfusion imaging (MPI). However, previously published methods have depended on polar maps, required manual correction, and normal database. In this study, we propose a polar map-free 3D DL algorithm to predict obstructive disease. METHODS We included 1861 subjects who underwent MPI using cadmium-zinc-telluride camera and subsequent coronary angiography. The subjects were divided into parameterization and external validation groups. We implemented a fully automatic algorithm to segment myocardium, perform registration, and apply normalization. We further flattened the image based on spherical coordinate system transformation. The proposed model consisted of a component to predict patent arteries and a component to predict disease in each vessel. The model was cross-validated in the parameterization group, and then further tested using the external validation group. The performance was assessed by area under receiver operating characteristic curves (AUCs) and compared with TPD. RESULTS Our algorithm preprocessed all images accurately as confirmed by visual inspection. In patient-based analysis, the AUC of the proposed model was significantly higher than that for stress-TPD (0.84 vs 0.76, p < 0.01). In vessel-based analysis, the proposed model also outperformed regional stress-TPD (AUC = 0.80 vs 0.72, p < 0.01). The addition of quantitative images did not improve the performance. CONCLUSIONS Our proposed polar map-free 3D DL algorithm to predict obstructive CAD from MPI outperformed TPD and did not require manual correction or a normal database.
Collapse
Affiliation(s)
- Chi-Lun Ko
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
- College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Shau-Syuan Lin
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan
| | - Cheng-Wen Huang
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan
| | - Yu-Hui Chang
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan
| | - Kuan-Yin Ko
- Department of Nuclear Medicine, National Taiwan University Cancer Center, Taipei, Taiwan
| | - Mei-Fang Cheng
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
- College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Shan-Ying Wang
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Chung-Ming Chen
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan
| | - Yen-Wen Wu
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan.
- College of Medicine, National Taiwan University, Taipei, Taiwan.
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan.
- Division of Cardiology, Cardiovascular Medical Center, Far Eastern Memorial Hospital, No. 21, Sec. 2, Nanya S. Rd., Banciao Dist., New Taipei City, 220, Taiwan.
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
- Graduate Institute of Medicine, Yuan Ze University, Taoyuan, Taiwan.
| |
Collapse
|
4
|
Pretorius PH, King MA. Data-driven respiratory signal estimation from temporally finely sampled projection data in conventional cardiac perfusion SPECT imaging. Med Phys 2022; 49:282-294. [PMID: 34859456 PMCID: PMC9348806 DOI: 10.1002/mp.15391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 10/28/2021] [Accepted: 11/19/2021] [Indexed: 01/03/2023] Open
Abstract
PURPOSE The aim of this work was to revisit the data-driven approach of axial center-of-mass (COM) measurements to recover a surrogate respiratory signal from finely sampled (100 ms) single photon emission computed tomography (SPECT) projection data derived from list-mode acquisitions. METHODS For our initial evaluation, we acquired list-mode projection data from an anthropomorphic cardiac phantom mounted on a Quasar respiratory motion platform simulating 15 mm amplitude respiratory motion. We also selected 302 consecutive patients (138 males, 164 females) with list-mode acquisitions, external respiratory motion tracking, and written consent to evaluate the clinical efficacy of our data-driven approach. Linear regression, Pearson's correlation coefficient (r), and standard error of the estimates (SEE) between the respiratory signals obtained with a visual tracking system (VTS) and COM measurements were calculated for individual projection data sets and for the patient group as a whole. Both the VTS- and COM-derived respiratory signals were used to estimate and correct respiratory motion. The reconstruction for six-degree of freedom rigid-body motion estimation was done in two ways: (1) using three iterations of ordered-subsets expectation-maximization (OSEM) with four subsets (16 projection angles per subset), or 12 iterations of maximum-likelihood expectation-maximization (MLEM). Respiratory motion compensation was done employing either OSEM with 16 subsets (four projection angles per subset) and five iterations or MLEM and 80 iterations, using the two respiratory estimates, respectively. Polar map quantification was also performed, calculating the percentage count difference (%Diff) between polar maps without and with respiratory motion included. Average % Diff was calculated in 17 segments (defined according to ASNC Guidelines). Paired t-tests were used to determine significance (p-values). RESULTS The r-value calculated when comparing the VTS and COM respiratory signals varied widely between -0.01 and 0.96 with an average of 0.70, while the SEE varied between 0.80 and 6.48 mm with an average of 2.05 mm for our patient set, while the same values for the one anthropomorphic phantom acquisition are 0.91 and 1.11 mm, respectively. A comparison between the respiratory motion estimates for VTS and COM in the S-I direction yielded an r = 0.90 (0.94), and an SEE of 1.56 mm (1.20 mm) for OSEM (MLEM), respectively. Bland-Altman plots and calculated intraclass correlation coefficients also showed excellent agreement between the VTS and COM respiratory motion estimates. Average S-I respiratory estimates for the VTS (COM) were 9.04 (9.2 mm) and 9.01 mm (9.14 mm) for the OSEM and MLEM, respectively. The paired t-test approached significance when comparing VTS and COM estimated respiratory signals with p-values of 0.069 and 0.051 for OSEM and MLEM. The respiratory estimates from the anthropomorphic cardiac phantom experiment using the VTS (COM) were 12.62 (14.10 mm) and 12.55 mm (14.29 mm) for OSEM and MLEM, respectively. Polar map quantification yielded average % Diff consistently better when employing VTS-derived respiratory estimates to correct for respiration compared to the COM-derived estimates. CONCLUSIONS The results indicate that our COM method has the potential to provide an automated data-driven correction of cardiac respiratory motion without the drawbacks of our VTS methodology. However, it is not generally equivalent to the VTS method in extent of correction.
Collapse
Affiliation(s)
- P Hendrik Pretorius
- Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts, USA
| | - Michael A King
- Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts, USA
| |
Collapse
|
5
|
Kyme AZ, Fulton RR. Motion estimation and correction in SPECT, PET and CT. Phys Med Biol 2021; 66. [PMID: 34102630 DOI: 10.1088/1361-6560/ac093b] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 06/08/2021] [Indexed: 11/11/2022]
Abstract
Patient motion impacts single photon emission computed tomography (SPECT), positron emission tomography (PET) and X-ray computed tomography (CT) by giving rise to projection data inconsistencies that can manifest as reconstruction artifacts, thereby degrading image quality and compromising accurate image interpretation and quantification. Methods to estimate and correct for patient motion in SPECT, PET and CT have attracted considerable research effort over several decades. The aims of this effort have been two-fold: to estimate relevant motion fields characterizing the various forms of voluntary and involuntary motion; and to apply these motion fields within a modified reconstruction framework to obtain motion-corrected images. The aims of this review are to outline the motion problem in medical imaging and to critically review published methods for estimating and correcting for the relevant motion fields in clinical and preclinical SPECT, PET and CT. Despite many similarities in how motion is handled between these modalities, utility and applications vary based on differences in temporal and spatial resolution. Technical feasibility has been demonstrated in each modality for both rigid and non-rigid motion, but clinical feasibility remains an important target. There is considerable scope for further developments in motion estimation and correction, and particularly in data-driven methods that will aid clinical utility. State-of-the-art machine learning methods may have a unique role to play in this context.
Collapse
Affiliation(s)
- Andre Z Kyme
- School of Biomedical Engineering, The University of Sydney, Sydney, New South Wales, AUSTRALIA
| | - Roger R Fulton
- Sydney School of Health Sciences, The University of Sydney, Sydney, New South Wales, AUSTRALIA
| |
Collapse
|
6
|
Effect of data conserving respiratory motion compensation on left ventricular functional parameters assessed in gated myocardial perfusion SPECT. EJNMMI Phys 2021; 8:7. [PMID: 33475904 PMCID: PMC7818343 DOI: 10.1186/s40658-021-00355-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 01/05/2021] [Indexed: 11/30/2022] Open
Abstract
Background Respiratory motion compromises image quality in myocardial perfusion (MP) single-photon emission computed tomography (SPECT) imaging and may affect analysis of left ventricular (LV) functional parameters, including phase analysis-quantified mechanical dyssynchrony parameters. In this paper, we investigate the performance of two algorithms, respiratory blur modeling (RBM) and joint motion-compensated (JMC) ordered-subsets expectation maximization (OSEM), and the effects of motion compensation on cardiac-gated MP-SPECT studies. Methods Image acquisitions were carried out with a dual-detector SPECT/CT system in list-mode format. A cardiac phantom was imaged as stationary and under respiratory motion. The images were reconstructed with OSEM, RBM-OSEM, and JMC-OSEM algorithms, and compared in terms of mean squared error (MSE). Subsequently, MP-SPECT data of 19 patients were binned into dual-gated (respiratory and cardiac gating) projection images. The images of the patients were analyzed with Quantitative Gated SPECT (QGS) 2012 program (Cedars-Sinai Medical Center, USA). The parameters of interest were LV volumes, ejection fraction, wall motion, wall thickening, phase analysis, and perfusion parameters. Results In phantom experiment, compared to the stationary OSEM reconstruction, the MSE values for OSEM, RBM-OSEM, and JMC-OSEM were 8.5406·10−5,2.7190·10−5, and 2.0795·10−5, respectively. In the analysis of LV function, use of JMC had a small but statistically significant (p < 0.05) effect on several parameters: it increased LV volumes and standard deviation of phase angle histogram, and it decreased ejection fraction, global wall motion, and lateral, septal, and apical perfusion. Conclusions Compared to standard OSEM algorithm, RBM-OSEM and JMC-OSEM both improve image quality under motion. Motion compensation has a minor effect on LV functional parameters. Supplementary Information The online version contains supplementary material available at (10.1186/s40658-021-00355-w).
Collapse
|
7
|
Benz DC, Buechel RR. The winding road towards respiratory motion correction: is this just another dead-end or do we finally get breathing under control? J Nucl Cardiol 2020; 27:2231-2233. [PMID: 30843146 DOI: 10.1007/s12350-019-01679-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Accepted: 02/22/2019] [Indexed: 11/28/2022]
Affiliation(s)
- Dominik C Benz
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland
| | - Ronny R Buechel
- Department of Nuclear Medicine, Cardiac Imaging, University Hospital Zurich, Ramistrasse 100, 8091, Zurich, Switzerland.
| |
Collapse
|
8
|
Zhang D, Sun J, Pretorius PH, King M, Mok GSP. Clinical evaluation of three respiratory gating schemes for different respiratory patterns on cardiac SPECT. Med Phys 2020; 47:4223-4232. [PMID: 32583468 DOI: 10.1002/mp.14354] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 06/12/2020] [Accepted: 06/15/2020] [Indexed: 11/06/2022] Open
Abstract
PURPOSE Respiratory gating reduces respiratory blur in cardiac single photon emission computed tomography (SPECT). It can be implemented as three gating schemes: (a) equal amplitude-based gating (AG); (b) phase or time-based gating (TG); or (c) equal count-based gating (CG), that is, a variant of amplitude-based method. The goal of this study is to evaluate the effectiveness of these respiratory gating methods for patients with different respiratory patterns in myocardial perfusion SPECT. METHODS We reviewed 1274 anonymized patient respiratory traces obtained via the Vicon motion-tracking system during their 99m Tc-sestamibi SPECT scans and grouped them into four breathing categories: (a) regular respiration (RR); (b) periodic respiration (PR); (c) respiration with apnea (AR); and (d) unclassified respiration (UR). For each respiratory pattern, 15 patients were randomly selected and their list-mode data were rebinned using the three gating schemes. A preliminary reconstruction was performed for each gate with the heart region segmented and registered to a reference gate to estimate the respiratory motion. A final reconstruction incorporating respiratory motion correction was done to get a final image set. The estimated respiratory motion, the full-width-at-half-maxima (FWHM) measured across the image intensity profile of the left ventricle wall, as well as the normalized standard deviation measured in a uniform cuboid region of the thorax were analyzed. RESULTS There are 47.1%, 24.3%, 13.5%, and 15.1% RR, PR, AR, and UR patients, respectively, among the 1274 patients in this study. The differences among the three gating schemes in RR were smaller than other respiratory patterns. The AG and CG methods showed statistically larger motion estimation than TG particularly in the AR and PR patterns. Noise of AG varied more in different gates, especially for AR and UR patterns. CONCLUSION More than half of the patients reviewed exhibited nonregular breathing patterns. Amplitude-based gating, that is, AG and CG, is a preferred gating method for such patterns and is a robust respiratory gating implementation method given the respiratory pattern of the patients is unknown before data acquisition. Phase gating is also a feasible option for regular respiratory pattern.
Collapse
Affiliation(s)
- Duo Zhang
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China
| | - Jingzhang Sun
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China
| | - P Hendrik Pretorius
- Department of Radiology, University of Massachusetts Medical School, Worcester, USA
| | - Michael King
- Department of Radiology, University of Massachusetts Medical School, Worcester, USA
| | - Greta S P Mok
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China.,Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Macau SAR, China
| |
Collapse
|
9
|
Okuda K, Nakajima K. Has the era of dual-gated myocardial perfusion SPECT and PET arrived? J Nucl Cardiol 2020; 27:648-650. [PMID: 30311136 DOI: 10.1007/s12350-018-1439-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2018] [Accepted: 08/31/2018] [Indexed: 10/28/2022]
Affiliation(s)
- Koichi Okuda
- Department of Physics, Kanazawa Medical University, 1-1 Daigaku, Uchinada, Kahoku, Ishikawa, 920-0293, Japan.
| | - Kenichi Nakajima
- Department of Nuclear Medicine, Kanazawa University Hospital, Kanazawa, Japan
| |
Collapse
|
10
|
Zhang D, Pretorius PH, Ghaly M, Zhang Q, King MA, Mok GSP. Evaluation of different respiratory gating schemes for cardiac SPECT. J Nucl Cardiol 2020; 27:634-647. [PMID: 30088195 PMCID: PMC11409049 DOI: 10.1007/s12350-018-1392-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Accepted: 07/17/2018] [Indexed: 11/26/2022]
Abstract
BACKGROUND Respiratory gating reduces motion blurring in cardiac SPECT. Here we aim to evaluate the performance of three respiratory gating strategies using a population of digital phantoms with known truth and clinical data. METHODS We analytically simulated 60 projections for 10 XCAT phantoms with 99mTc-sestamibi distributions using three gating schemes: equal amplitude gating (AG), equal count gating (CG), and equal time gating (TG). Clinical list-mode data for 10 patients who underwent 99mTc-sestamibi scans were also processed using the 3 gating schemes. Reconstructed images in each gate were registered to a reference gate, averaged and reoriented to generate the polar plots. For simulations, image noise, relative difference (RD) of averaged count for each of the 17 segment, and relative defect size difference (RSD) were analyzed. For clinical data, image intensity profile and FWHM were measured across the left ventricle wall. RESULTS For simulations, AG and CG methods showed significantly lower RD and RSD compared to TG, while noise variation was more non-uniform through different gates for AG. In the clinical study, AG and CG had smaller FWHM than TG. CONCLUSIONS AG and CG methods show better performance for motion reduction and are recommended for clinical respiratory gating SPECT implementation.
Collapse
Affiliation(s)
- Duo Zhang
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
- Department of Radiology, University of Massachusetts Medical School, Worcester, USA
| | - P Hendrik Pretorius
- Department of Radiology, University of Massachusetts Medical School, Worcester, USA
| | - Michael Ghaly
- The Russell H Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
- Radiopharmaceutical Imaging and Dosimetry (RAPID), LLC, Baltimore, MD, USA
| | - Qi Zhang
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
| | - Michael A King
- Department of Radiology, University of Massachusetts Medical School, Worcester, USA
| | - Greta S P Mok
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China.
- Department of Radiology, University of Massachusetts Medical School, Worcester, USA.
- Faculty of Health Sciences, University of Macau, Taipa, Macau SAR, China.
| |
Collapse
|
11
|
Lin WL, Wang SY, Shiau YC, Wu YW. The clinical usefulness of phase analysis in detecting coronary artery disease using dipyridamole thallium-201-gated myocardial perfusion imaging with a cadmium-zinc-telluride camera. J Nucl Cardiol 2020; 27:241-250. [PMID: 30171522 DOI: 10.1007/s12350-018-1417-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2018] [Accepted: 08/02/2018] [Indexed: 11/30/2022]
Abstract
BACKGROUND Previous studies have demonstrated left ventricular mechanical dyssynchrony (LVMD) in patients with severe coronary artery disease (CAD) with ≥ 70% stenosis. The aim of this study was to evaluate the clinical usefulness of stress/rest LVMD in the diagnosis of CAD with ≥ 50% stenosis using dipyridamole thallium-201 (Tl-201) myocardial perfusion imaging (MPI) with a cadmium-zinc-telluride camera. METHODS AND RESULTS A total of 476 patients without known CAD who underwent dipyridamole Tl-201 MPI and coronary angiography within 6 months were retrospectively reviewed. LVMD parameters including phase standard deviation and phase histogram bandwidth, phase skewness and phase kurtosis, as well as myocardial perfusion and myocardial stunning were assessed in post-stress and rest MPI. Relationships between the presence of CAD on coronary angiography and single photon emission computerized tomography (SPECT) parameters were evaluated. The presence of perfusion abnormalities was the best diagnostic tool in detecting CAD. Although less left ventricular synchrony was observed post-stress in the CAD group compared to the non-CAD group, no significant dyssynchrony was noted. CONCLUSIONS The addition of phase analysis to help diagnose CAD in Tl-201-gated SPECT with dipyridamole stress may have limited value in patients with CAD with ≥ 50% stenosis.
Collapse
Affiliation(s)
- Wan-Ling Lin
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, No. 21, Sec. 2, Nanya S. Rd., Banciao Dist., New Taipei City, 220, Taiwan
- Department of Nuclear Medicine, National Taiwan University Hospital Hsin-Chu Branch, Hsinchu City, Taiwan
| | - Shan-Ying Wang
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, No. 21, Sec. 2, Nanya S. Rd., Banciao Dist., New Taipei City, 220, Taiwan
| | - Yu-Chien Shiau
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, No. 21, Sec. 2, Nanya S. Rd., Banciao Dist., New Taipei City, 220, Taiwan
| | - Yen-Wen Wu
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, No. 21, Sec. 2, Nanya S. Rd., Banciao Dist., New Taipei City, 220, Taiwan.
- National Yang-Ming University School of Medicine, Taipei City, Taiwan.
- Department of Nuclear Medicine, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei City, Taiwan.
| |
Collapse
|
12
|
Ko KY, Wang SY, Yen RF, Shiau YC, Hsu JC, Tsai HY, Lee CL, Chiu KM, Wu YW. Clinical significance of quantitative assessment of glucose utilization in patients with ischemic cardiomyopathy. J Nucl Cardiol 2020; 27:269-279. [PMID: 30109593 DOI: 10.1007/s12350-018-1395-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Accepted: 07/27/2018] [Indexed: 12/11/2022]
Abstract
BACKGROUND The aim of this study was to prospectively quantify the rate of myocardial glucose uptake (MRGlu) in myocardium with different perfusion-metabolism patterns and determine its prognostic value in patients with ischemic cardiomyopathy. METHODS AND RESULTS 79 patients with ischemic cardiomyopathy were prospectively enrolled for dynamic cardiac FDG PET, and then followed for at least 6 months. Perfusion-metabolism patterns were determined based on visual score analysis of 201Tl SPECT and FDG PET. MRGlu was analyzed using the Patlak kinetic model. The primary end-point was cardiovascular mortality. Significantly higher MRGlu was observed in viable compared with non-viable areas. Negative correlations were found between MRGlu in transmural match and a history of hyperlipidemia, statin usage, and triglyceride levels. Diabetic patients receiving dipeptidyl peptidase-4 inhibitors (DPP4i) had a significantly lower MRGlu in transmural match, mismatch, and reverse mismatch. Patients with MRGlu in transmural match ≥ 23.40 or reverse mismatch ≥ 36.90 had a worse outcome. CONCLUSIONS Myocardial glucose utilization was influenced by substrates and medications, including statins and DPP4i. MRGlu could discriminate between viable and non-viable myocardium, and MRGlu in transmural match and reverse mismatch may be prognostic predictors of cardiovascular death in patients with ischemic cardiomyopathy.
Collapse
Affiliation(s)
- Kuan-Yin Ko
- Department of Nuclear Medicine, National Taiwan University Hospital, Yunlin Branch, Yunlin County, Taiwan
- Graduate Institute of Clinical Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Shan-Ying Wang
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Ruoh-Fang Yen
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
- National Taiwan University College of Medicine, Taipei, Taiwan
| | - Yu-Chien Shiau
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Jung-Cheng Hsu
- Division of Cardiology, Cardiovascular Medical Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Hao-Yuan Tsai
- Division of Cardiology, Cardiovascular Medical Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Chien-Lin Lee
- Division of Cardiology, Cardiovascular Medical Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Kuan-Ming Chiu
- Division of Cardiovascular Surgery, Cardiovascular Medical Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Yen-Wen Wu
- Graduate Institute of Clinical Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan.
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan.
- Division of Cardiology, Cardiovascular Medical Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan.
- National Yang-Ming University School of Medicine, Taipei, Taiwan.
| |
Collapse
|
13
|
Pretorius PH, Johnson KL, Dahlberg ST, King MA. Investigation of the physical effects of respiratory motion compensation in a large population of patients undergoing Tc-99m cardiac perfusion SPECT/CT stress imaging. J Nucl Cardiol 2020; 27:80-95. [PMID: 28432671 PMCID: PMC7714447 DOI: 10.1007/s12350-017-0890-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2017] [Accepted: 04/02/2017] [Indexed: 10/19/2022]
Abstract
BACKGROUND Respiratory motion can deteriorate image fidelity in cardiac perfusion SPECT. We determined the extent of respiratory motion, assessed its impact on image fidelity, and investigated the existence of gender differences, thereby examining the influence of respiratory motion in a large population of patients. METHODS One thousand one hundred and three SPECT/CT patients underwent visual tracking of markers on their anterior surface during stress acquisition to track respiratory motion. The extent of motion was estimated by registration. Visual indicators of changes in cardiac slices with motion correction, and the correlation between the extent of motion with changes in segmental-counts were assessed. RESULTS Respiratory motion in the head-to-feet direction was the largest component of motion, varying between 1.1 and 37.4 mm, and was statistically significantly higher (p = 0.002) for males than females. In 33.0% of the patients, motion estimates were larger than 10 mm. Patients progressively show more distinct visual changes with an increase in the extent of motion. The increase in segmental-count differences in the anterior, antero-lateral, and inferior segments correlated with the extent of motion. CONCLUSIONS Respiratory motion correction diminished the artefactual reduction in anterior and inferior wall counts associated with respiratory motion. The extent of improvement was strongly related to the magnitude of motion.
Collapse
Affiliation(s)
- P Hendrik Pretorius
- Department of Radiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, MA, 01655, USA.
| | - Karen L Johnson
- Department of Radiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, MA, 01655, USA
| | - Seth T Dahlberg
- Department of Radiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, MA, 01655, USA
| | - Michael A King
- Department of Radiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, MA, 01655, USA
| |
Collapse
|
14
|
Liu FS, Wang SY, Shiau YC, Wu YW. The clinical value and safety of ECG-gated dipyridamole myocardial perfusion imaging in patients with aortic stenosis. Sci Rep 2019; 9:12443. [PMID: 31455862 PMCID: PMC6712027 DOI: 10.1038/s41598-019-48901-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Accepted: 08/15/2019] [Indexed: 12/31/2022] Open
Abstract
The role of vasodilator myocardial perfusion imaging (MPI) for aortic stenosis (AS) is controversial due to safety and accuracy concerns. In addition, its utility after aortic valve (AV) interventions remains unclear. Patients with AS who underwent thallium-201-gated dipyridamole MPI using a cadmium-zinc-telluride camera were retrospectively reviewed and divided into three groups: mild AS, moderate-to-severe AS, and prior AV interventions. Patients with coronary artery disease with ≥50% stenosis, severe arrhythmia, left ventricular ejection fraction (LVEF) <40%, left bundle branch block or no follow-up were excluded. Relationships between the severity of AS, clinical characteristics, hemodynamic response, serious adverse events (SAE) and MPI parameters were analyzed. None of the 47 patients had SAE, including significant hypotension or LVEF reduction. The moderate-to-severe AS group had higher summed stress scores (SSSs) and depressed LVEF than the mild AS group, however there were no differences after AV interventions. SSS was positively correlated with AV mean pressure gradient, post-stress lung-heart ratio (LHRs), and post-stress end-diastolic volume (EDVs) (P < 0.05). In multivariate analysis, LHRs and EDVs were independent contributors to SSS. Dipyridamole-induced ischemia and LV dysfunction is common, and dipyridamole stress could be a safe diagnostic tool in evaluation and follow-up in patients with AS.
Collapse
Affiliation(s)
- Fang-Shin Liu
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Shan-Ying Wang
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan.,Department of Nuclear Medicine, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei City, Taiwan
| | - Yu-Chien Shiau
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Yen-Wen Wu
- Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan. .,Division of Cardiology, Cardiovascular Medical Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan. .,National Yang-Ming University School of Medicine, Taipei, Taiwan. .,Department of Nuclear Medicine, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei City, Taiwan.
| |
Collapse
|
15
|
Daou D. Dedicated cardiac CZT SPECT is steadily moving to achieve its destiny. J Nucl Cardiol 2019; 26:453-455. [PMID: 28744820 DOI: 10.1007/s12350-017-1006-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2017] [Accepted: 07/17/2017] [Indexed: 01/26/2023]
Affiliation(s)
- Doumit Daou
- EA 7334 REMES, Université Paris-Diderot, Sorbonne Paris-Cité, Paris, France.
- Nuclear Medicine Department, Cochin University Hospital, 27 rue du Faubourg Saint-Jacques, 75679, Paris Cedex 14, France.
| |
Collapse
|
16
|
Abstract
Cardiac SPECT continues to play a critical role in detecting and managing cardiovascular disease, in particularly coronary artery disease (CAD) (Jaarsma et al 2012 J. Am. Coll. Cardiol. 59 1719-28), (Agostini et al 2016 Eur. J. Nucl. Med. Mol. Imaging 43 2423-32). While conventional dual-head SPECT scanners using parallel-hole collimators and scintillation crystals with photomultiplier tubes are still the workhorse of cardiac SPECT, they have the limitations of low photon sensitivity (~130 count s-1 MBq-1), poor image resolution (~15 mm) (Imbert et al 2012 J. Nucl. Med. 53 1897-903), relatively long acquisition time, inefficient use of the detector, high radiation dose, etc. Recently our field observed an exciting growth of new developments of dedicated cardiac scanners and collimators, as well as novel imaging algorithms for quantitative cardiac SPECT. These developments have opened doors to new applications with potential clinical impact, including ultra-low-dose imaging, absolute quantification of myocardial blood flow (MBF) and coronary flow reserve (CFR), multi-radionuclide imaging, and improved image quality as a result of attenuation, scatter, motion, and partial volume corrections (PVCs). In this article, we review the recent advances in cardiac SPECT instrumentation and imaging methods. This review mainly focuses on the most recent developments published since 2012 and points to the future of cardiac SPECT from an imaging physics perspective.
Collapse
Affiliation(s)
- Jing Wu
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, United States of America
| | | |
Collapse
|
17
|
Effect of respiratory motion on cardiac defect contrast in myocardial perfusion SPECT: a physical phantom study. Ann Nucl Med 2019; 33:305-316. [PMID: 30680536 PMCID: PMC6497623 DOI: 10.1007/s12149-019-01335-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Accepted: 01/14/2019] [Indexed: 12/27/2022]
Abstract
Objective Correction for respiratory motion in myocardial perfusion imaging requires sorting of emission data into respiratory windows where the intra-window motion is assumed to be negligible. However, it is unclear how much intra-window motion is acceptable. The aim of this study was to determine an optimal value of intra-window residual motion. Methods A custom-designed cardiac phantom was created and imaged with a standard dual-detector SPECT/CT system using Tc-99m as the radionuclide. Projection images were generated from the list-mode data simulating respiratory motion blur of several magnitudes from 0 (stationary phantom) to 20 mm. Cardiac defect contrasts in six anatomically different locations, as well as myocardial perfusion of apex, anterior, inferior, septal and lateral walls, were measured at each motion magnitude. Stationary phantom data were compared to motion-blurred data. Two physicians viewed the images and evaluated differences in cardiac defect visibility and myocardial perfusion. Results Significant associations were observed between myocardial perfusion in the anterior and inferior walls and respiratory motion. Defect contrasts were found to decline as a function of motion, but the magnitude of the decline depended on the location and shape of the defect. Defects located near the cardiac apex lost contrast more rapidly than those located on the anterior, inferior, septal and lateral wall. The contrast decreased by less than 5% at every location when the motion magnitude was 2 mm or less. According to a visual evaluation, there were differences in myocardial perfusion if the magnitude of the motion was greater than 1 mm, and there were differences in the visibility of the cardiac defect if the magnitude of the motion was greater than 9 mm. Conclusions Intra-window respiratory motion should be limited to 2 mm to effectively correct for respiratory motion blur in myocardial perfusion SPECT.
Collapse
|
18
|
Kortelainen MJ, Koivumäki TM, Vauhkonen MJ, Hedman MK, Kärkkäinen STJ, Niño Quintero J, Hakulinen MA. Respiratory motion reduction with a dual gating approach in myocardial perfusion SPECT: Effect on left ventricular functional parameters. J Nucl Cardiol 2018; 25:1633-1641. [PMID: 28303474 DOI: 10.1007/s12350-017-0844-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Revised: 02/06/2017] [Indexed: 11/30/2022]
Abstract
BACKGROUND Respiratory motion (RM) complicates the analysis of myocardial perfusion (MP) single-photon emission computed tomography (SPECT) images. The effects of RM on left ventricular (LV) functional variables have not been thoroughly investigated. METHODS AND RESULTS Thoracic electrical bioimpedance and electrocardiographic signals were recorded from eighteen patients undergoing the rest phase of a 1-day stress/rest cardiac-gated MP-SPECT examination. The signals and list-mode emission data were retrospectively processed to yield standard cardiac- and dual-gated (respiratory and cardiac gating) image sets applying a novel algorithm. LV volume, MP, shape index (SI), wall motion (WM), wall thickening (WT), and phase analysis parameters were measured with Quantitative Perfusion SPECT/Quantitative Gated SPECT software (Cedars-Sinai Medical Center). Image quality was evaluated by three experienced physicians. Dual gating increased LV volume (77.1 ± 26.8 vs 79.8 ± 27.6 mL, P = .006) and decreased SI (0.57 ± 0.05 vs 0.56 ± 0.05, P = .036) and global WT (39.0 ± 11.8% vs 36.9 ± 9.4%, P = .034) compared to cardiac gating, but did not significantly alter perfusion, WM or phase analysis parameters or image quality (P > .05). CONCLUSIONS RM reduction has an effect on LV volume, shape, and WT parameters. RM exerts no significant effect on phase analysis parameters.
Collapse
Affiliation(s)
- Matti J Kortelainen
- Department of Applied Physics, University of Eastern Finland, POB 1627, 70211, Kuopio, Finland.
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.
| | | | - Marko J Vauhkonen
- Department of Applied Physics, University of Eastern Finland, POB 1627, 70211, Kuopio, Finland
| | - Marja K Hedman
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
- Heart Center, Kuopio University Hospital, Kuopio, Finland
| | | | | | - Mikko A Hakulinen
- Department of Applied Physics, University of Eastern Finland, POB 1627, 70211, Kuopio, Finland
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| |
Collapse
|
19
|
Giannopoulos AA, Buechel RR. A further step towards getting cardiac respiratory motion under control. J Nucl Cardiol 2018; 25:1310-1312. [PMID: 28247262 DOI: 10.1007/s12350-017-0835-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2017] [Accepted: 02/17/2017] [Indexed: 10/20/2022]
Affiliation(s)
- Andreas A Giannopoulos
- Cardiac Imaging, Department of Nuclear Medicine, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland
| | - Ronny R Buechel
- Cardiac Imaging, Department of Nuclear Medicine, University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
| |
Collapse
|
20
|
Daou D, Sabbah R, Coaguila C, Boulahdour H. Impact of data-driven cardiac respiratory motion correction on the extent and severity of myocardial perfusion defects with free-breathing CZT SPECT. J Nucl Cardiol 2018; 25:1299-1309. [PMID: 28160264 DOI: 10.1007/s12350-017-0806-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Revised: 12/24/2016] [Indexed: 11/25/2022]
Abstract
BACKGROUND We previously reported the clinical feasibility and positive impact on image characteristics of a data-driven cardiac respiratory motion (RM) correction method (REGAT) applicable to CZT SPECT myocardial perfusion imaging (MPI). Here, we evaluate its impact on the extent and severity of myocardial perfusion defects (MPD). METHODS We included 25 patients having a 1-day 99mTc-Tetrofosmin stress/rest MPI acquired with multi-pinhole CZT SPECT. Acquisitions were processed with REGAT to generate mean RM gated SPECT. These were summed either after (R-SPECT) or without realignment (NR-SPECT). We noted the maximal cardiac RM shift in the 3 axes of the left ventricle (LV). Both visual and semi-quantitative analyses of myocardial tracer uptake were realized. Studies were classified as having an impact on the extent/severity of MPD with REGAT if ≥1 segment presented a severity score changing by ≥1 level between NR-SPECT and R-SPECT. An impact on the extent of MPD was considered present if at least 1 segment shifted from normal (score = 0) to abnormal (score different from 0) or inversely. RESULTS Cardiac RM was >10 mm in 55% of studies. With visual and semi-quantitative analyses, an impact on the extent/severity MPD was observed in 14% of all studies (7/49) and 60% of studies with cardiac RM >15 mm. An impact on the extent of MPD was observed in 5 of the 7 upper listed studies. All studies presenting an impact on MPD had RM in the anterior to inferior LV axis >10 mm. CONCLUSIONS A substantial number of MPI studies presented significant cardiac RM. Cardiac RM compensation showed a frequent impact on the extent/severity of MPD.
Collapse
Affiliation(s)
- Doumit Daou
- EA 7334 REMES, Université Paris-Diderot, Sorbonne Paris-Cité, Paris, France.
- Nuclear Medicine Department, Cochin University Hospital, AP-HP, 27 rue du Faubourg Saint-Jacques, 75679, Paris Cedex 14, France.
| | - Rémy Sabbah
- Nuclear Medicine Department, CHU Jean Minjoz, Besançon, France
| | - Carlos Coaguila
- Nuclear Medicine Department, Centre Hospitalier de Bigorre, Tarbes, France
| | | |
Collapse
|
21
|
Benz DC, Fuchs TA. Breathless or breathtaking: Respiratory motion correction. J Nucl Cardiol 2018; 25:429-432. [PMID: 27435279 DOI: 10.1007/s12350-016-0590-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2016] [Accepted: 07/05/2016] [Indexed: 11/26/2022]
Affiliation(s)
- Dominik C Benz
- Department of Nuclear Medicine, University Hospital Zurich, Ramistr 100, 8091, Zurich, Switzerland
| | - Tobias A Fuchs
- Department of Nuclear Medicine, University Hospital Zurich, Ramistr 100, 8091, Zurich, Switzerland.
| |
Collapse
|
22
|
van Dijk JD, van Dalen JA, Mouden M, Ottervanger JP, Knollema S, Slump CH, Jager PL. Value of automatic patient motion detection and correction in myocardial perfusion imaging using a CZT-based SPECT camera. J Nucl Cardiol 2018; 25:419-428. [PMID: 27406376 PMCID: PMC5869883 DOI: 10.1007/s12350-016-0571-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2016] [Accepted: 06/01/2016] [Indexed: 12/30/2022]
Abstract
BACKGROUND Correction of motion has become feasible on cadmium-zinc-telluride (CZT)-based SPECT cameras during myocardial perfusion imaging (MPI). Our aim was to quantify the motion and to determine the value of automatic correction using commercially available software. METHODS AND RESULTS We retrospectively included 83 consecutive patients who underwent stress-rest MPI CZT-SPECT and invasive fractional flow reserve (FFR) measurement. Eight-minute stress acquisitions were reformatted into 1.0- and 20-second bins to detect respiratory motion (RM) and patient motion (PM), respectively. RM and PM were quantified and scans were automatically corrected. Total perfusion deficit (TPD) and SPECT interpretation-normal, equivocal, or abnormal-were compared between the noncorrected and corrected scans. Scans with a changed SPECT interpretation were compared with FFR, the reference standard. Average RM was 2.5 ± 0.4 mm and maximal PM was 4.5 ± 1.3 mm. RM correction influenced the diagnostic outcomes in two patients based on TPD changes ≥7% and in nine patients based on changed visual interpretation. In only four of these patients, the changed SPECT interpretation corresponded with FFR measurements. Correction for PM did not influence the diagnostic outcomes. CONCLUSION Respiratory motion and patient motion were small. Motion correction did not appear to improve the diagnostic outcome and, hence, the added value seems limited in MPI using CZT-based SPECT cameras.
Collapse
Affiliation(s)
- Joris D van Dijk
- Department of Nuclear Medicine, Isala Hospital, PO Box 10400, 8000, Zwolle, GK, The Netherlands.
- MIRA: Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands.
| | - Jorn A van Dalen
- Department of Medical Physics, Isala Hospital, Zwolle, The Netherlands
| | - Mohamed Mouden
- Department of Cardiology, Isala Hospital, Zwolle, The Netherlands
| | | | - Siert Knollema
- Department of Nuclear Medicine, Isala Hospital, PO Box 10400, 8000, Zwolle, GK, The Netherlands
| | - Cornelis H Slump
- MIRA: Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
| | - Pieter L Jager
- Department of Nuclear Medicine, Isala Hospital, PO Box 10400, 8000, Zwolle, GK, The Netherlands
| |
Collapse
|
23
|
Mechanical dyssynchrony and diastolic dysfunction are common in LVH: a pilot correlation study using Doppler echocardiography and CZT gated-SPECT MPI. Sci Rep 2018. [PMID: 29520004 PMCID: PMC5843584 DOI: 10.1038/s41598-018-22213-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
Hypertrophic cardiomyopathy (HCM) is an often under-diagnosed cause of left ventricular hypertrophy (LVH). It affects 1/500 of the population, is the most commonly inherited cardiovascular disorder, and can present in apical, concentric, or septal forms. Although most patients are asymptomatic, sudden cardiac death can be the initial presentation of HCM. By retrospectively enrolling patients suspected of having three different types of HCM in the absence of epicardial coronary stenosis, we aimed to examine systolic and diastolic dysfunction and perfusion abnormalities using both Doppler echocardiography and state-of-the-art gated single-photon emission computerized tomography (SPECT) myocardial perfusion imaging (MPI) with a cadmium-zinc-telluride camera and thallium-201. Both regional perfusion and gated SPECT parameters were collected in addition to diastolic parameters from Doppler echocardiography. The results showed that mild ischemia was common in patients suspected of having HCM, with a mean summed stress score of 4.7 ± 4.9 (score 0–4 in 17-segment model). The patients with HCM were associated with discernible left ventricular mechanical dyssynchrony, especially those with the apical form. In addition, diastolic dysfunction was prevalent and early to late ventricular filling velocity ratios were significantly different between groups. By combining gated-MPI and Doppler data, the trivial functional changes in HCM may be identified.
Collapse
|
24
|
Ljungberg M, Pretorius PH. SPECT/CT: an update on technological developments and clinical applications. Br J Radiol 2018; 91:20160402. [PMID: 27845567 PMCID: PMC5966195 DOI: 10.1259/bjr.20160402] [Citation(s) in RCA: 65] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 09/28/2016] [Accepted: 11/10/2016] [Indexed: 12/20/2022] Open
Abstract
Functional nuclear medicine imaging with single-photon emission CT (SPECT) in combination with anatomical CT has been commercially available since the beginning of this century. The combination of the two modalities has improved both the sensitivity and specificity of many clinical applications and CT in conjunction with SPECT that allows for spatial overlay of the SPECT data on good anatomy images. Introduction of diagnostic CT units as part of the SPECT/CT system has also potentially allowed for a more cost-efficient use of the equipment. Most of the SPECT systems available are based on the well-known Anger camera principle with NaI(Tl) as a scintillation material, parallel-hole collimators and multiple photomultiplier tubes, which, from the centroid of the scintillation light, determine the position of an event. Recently, solid-state detectors using cadmium-zinc-telluride became available and clinical SPECT cameras employing multiple pinhole collimators have been developed and introduced in the market. However, even if new systems become available with better hardware, the SPECT reconstruction will still be affected by photon attenuation and scatter and collimator response. Compensation for these effects is needed even for qualitative studies to avoid artefacts leading to false positives. This review highlights the recent progress for both new SPECT cameras systems as well as for various data-processing and compensation methods.
Collapse
Affiliation(s)
- Michael Ljungberg
- Department of Medical Radiation Physics, Lund University, Lund, Sweden
| | - P Hendrik Pretorius
- Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Medical School, Worcester, MA, USA
| |
Collapse
|
25
|
Daou D, Sabbah R, Coaguila C, Boulahdour H. Feasibility of data-driven cardiac respiratory motion correction of myocardial perfusion CZT SPECT: A pilot study. J Nucl Cardiol 2017; 24:1598-1607. [PMID: 27170338 DOI: 10.1007/s12350-016-0493-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2016] [Accepted: 03/29/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND We developed a data-driven respiratory motion (RM) correction method (REGAT program) for multiple-pinhole detector CZT SPECT. We verified its clinical feasibility with myocardial perfusion imaging (MPI) and studied its impact on image characteristics. METHODS This retrospective study included 18 patients having stress/rest 99mTc-Tetrofosmin MPI SPECT. List mode was acquired on CZT SPECT and processed with REGAT. REGAT generates reconstructed RM-gated volumes that are summed either without realignment (NR-SPECT) or after realignment (R-SPECT). For both stress and rest, we calculated the maximal RM in the 3 axis, and image characteristics of both R-SPECT and NR-SPECT: minimum left ventricular (LV) cavity counts (LV-Min), maximum LV myocardial counts (LV-Max), LV contrast, and FWHM of both anterior (FWHM-ant) and inferior (FWHM-inf) LV myocardial walls. RESULTS At both stress and rest, cranio-caudal motion was the dominant axial movement and REGAT had a positive impact on image characteristics as reflected by variations between R-SPECT and NR-SPECT in LV-Min, LV-Max, FWHM-ant, FWHM-inf, and contrast. These latter were well correlated to the amplitude of cranio-caudal motion at both stress and rest. CONCLUSIONS Data-driven RM correction of MPI acquired with CZT SPECT is clinically feasible and easily applicable. It presents interesting impact on image characteristics.
Collapse
Affiliation(s)
- Doumit Daou
- EA 7334 REMES, Université Paris-Diderot, Sorbonne Paris-Cité, Paris, France.
- Nuclear Medicine Department, Cochin University Hospital, AP-HP, 27 rue du Faubourg Saint-Jacques, 75679, Paris Cedex 14, France.
| | - Rémy Sabbah
- Nuclear Medicine Department, CHU Jean Minjoz, Besançon, France
| | - Carlos Coaguila
- Nuclear Medicine Department, Centre Hospitalier de Bigorre, Tarbes, France
| | | |
Collapse
|
26
|
Polycarpou I, Chrysanthou-Baustert I, Demetriadou O, Parpottas Y, Panagidis C, Marsden PK, Livieratos L. Impact of respiratory motion correction on SPECT myocardial perfusion imaging using a mechanically moving phantom assembly with variable cardiac defects. J Nucl Cardiol 2017; 24:1216-1225. [PMID: 26676030 DOI: 10.1007/s12350-015-0323-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Accepted: 10/26/2015] [Indexed: 10/22/2022]
Abstract
BACKGROUND The aim of this study was to determine the impact of respiratory motion correction on SPECT MPI and on defect detection using a phantom assembly. METHODS SPECT/CT data were acquired using an anthropomorphic phantom with inflatable lungs and with an ECG beating and moving cardiac compartment. The heart motion followed the respiratory pattern in the cranio-caudal direction to simulate normal or deep breathing. Small or large transmural defects were inserted into the myocardial wall of the left ventricle. SPECT/CT images were acquired for each of the four respiratory phases, from exhale to inhale. A respiratory motion correction was applied using an image-based method with transformation parameters derived from the SPECT data by a non-rigid registration algorithm. A report on defect detection from two physicians and a quantitative analysis on MPI data were performed before and after applying motion correction. RESULTS Respiratory motion correction eliminated artifacts present in the images, resulting in a uniform uptake and reduction of motion blurring, especially in the inferior and anterior regions of the LV myocardial walls. The physicians' report after motion correction showed that images were corrected for motion. CONCLUSIONS A combination of motion correction with attenuation correction reduces artifacts in SPECT MPI. AC-SPECT images with and without motion correction should be simultaneously inspected to report on small defects.
Collapse
Affiliation(s)
- Irene Polycarpou
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.
- Department of Health Sciences, European University Cyprus, Nicosia, Cyprus.
| | | | | | - Yiannis Parpottas
- Frederick Research Center, Nicosia, Cyprus
- General Department (Physics-Mathematics), Frederick University, Nicosia, Cyprus
| | | | - Paul K Marsden
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom
| | - Lefteris Livieratos
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom
- Guy's and St Thomas' Hospitals NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
27
|
Clinical significance of right ventricular activity on treadmill thallium-201 myocardial single-photon emission computerized tomography using cadmium-zinc-telluride cameras. Nucl Med Commun 2017; 37:650-7. [PMID: 27110956 DOI: 10.1097/mnm.0000000000000494] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Identification of right ventricular (RV) abnormalities is important in patients with suspected coronary artery disease (CAD). RV activity can be better visualized on myocardial single-photon emission computerized tomography (SPECT) using a higher sensitivity cadmium-zinc-telluride (CZT) detector. The aim of this study was to investigate the clinical significance of RV/left ventricular (LV) uptake ratios during exercise thallium-201 SPECT using CZT detectors. PATIENTS AND METHODS A total of 102 patients underwent treadmill ECG-gated SPECT, coronary angiography, and echocardiography. SPECT myocardial perfusion was interpreted using a 17-segment model and a 0-4-point scale. RV/LV uptake ratios were calculated on the basis of maximum counts per pixel within the entire RV and LV walls. The relationships between RV/LV uptake ratio and gated SPECT, presence of CAD (≥50% stenosis in the left main or ≥70% in the main branches), demographics, and echocardiographic parameters were analyzed. RESULTS Stress RV/LV ratios correlated positively with the presence of left main or multivessel disease, and tricuspid regurgitation maximum pressure gradient. After multivariate regression, stress/rest RV/LV ratios correlated positively with mitral flow deceleration time, age, female sex, and use of β-blockers. CONCLUSION RV/LV uptake ratios on the basis of exercise myocardial perfusion SPECT imaging using CZT cameras are useful for the detection of severe CAD and could serve as an indicator of pulmonary hypertension and LV diastolic dysfunction.
Collapse
|
28
|
Sanders JC, Ritt P, Kuwert T, Vija AH, Maier AK. Fully Automated Data-Driven Respiratory Signal Extraction From SPECT Images Using Laplacian Eigenmaps. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:2425-2435. [PMID: 27295657 DOI: 10.1109/tmi.2016.2576899] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
We propose a data-driven method for extracting a respiratory surrogate signal from SPECT list-mode data. The approach is based on dimensionality reduction with Laplacian Eigenmaps. By setting a scale parameter adaptively and adding a series of post-processing steps to correct polarity and normalization between projections, we enable fully-automatic operation and deliver a respiratory surrogate signal for the entire SPECT acquisition. We validated the method using 67 patient scans from three acquisition types (myocardial perfusion, liver shunt diagnostic, lung inhalation/perfusion) and an Anzai pressure belt as a gold standard. The proposed method achieved a mean correlation against the Anzai of 0.81 ± 0.17 (median 0.89). In a subsequent analysis, we characterize the performance of the method with respect to count rates and describe a predictor for identifying scans with insufficient statistics. To the best of our knowledge, this is the first large validation of a data-driven respiratory signal extraction method published thus far for SPECT, and our results compare well with those reported in the literature for such techniques applied to other modalities such as MR and PET.
Collapse
|
29
|
Motion detection and amelioration in a dedicated cardiac solid-state CZT SPECT device. Med Biol Eng Comput 2016; 55:663-671. [DOI: 10.1007/s11517-016-1548-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2015] [Accepted: 07/07/2016] [Indexed: 11/26/2022]
|
30
|
Hung GU, Wang YF, Su HY, Hsieh TC, Ko CL, Yen RF. New Trends in Radionuclide Myocardial Perfusion Imaging. ACTA CARDIOLOGICA SINICA 2016; 32:156-66. [PMID: 27122946 DOI: 10.6515/acs20150803a] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
UNLABELLED Radionuclide myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) has been widely used clinically as one of the major functional imaging modalities for patients with coronary artery disease (CAD) for decades. Ample evidence has supported the use of MPI as a useful and important tool in the diagnosis, risk stratification and treatment planning for CAD. Although popular in the United States, MPI has become the most frequently used imaging modality among all nuclear medicine tests in Taiwan. However, it should be acknowledged that MPI SPECT does have its limitations. These include false-positive results due to certain artifacts, false-negative due to balanced ischemia, complexity and adverse reaction arising from current pharmacological stressors, time consuming nature of the imaging procedure, no blood flow quantitation and relatively high radiation exposure. The purpose of this article was to review the recent trends in nuclear cardiology, including the utilization of positron emission tomography (PET) for MPI, new stressor, new SPECT camera with higher resolution and higher sensitivity, dynamic SPECT protocol for blood flow quantitation, new software of phase analysis for evaluation of LV dyssynchrony, and measures utilized for reducing radiation exposure of MPI. KEY WORDS Coronary artery disease • Myocardial flow reserve • Myocardial perfusion imaging • Phase analysis • PET • SPECT.
Collapse
Affiliation(s)
- Guang-Uei Hung
- Department of Nuclear Medicine, Chang Bing Show Chwan Memorial Hospital, Changhua
| | - Yuh-Feng Wang
- Department of Nuclear Medicine, Buddhist Dalin Tzu Chi General Hospital, Chiayi; ; School of Medicine, Tzu Chi University, Hualian
| | - Hung-Yi Su
- Department of Nuclear Medicine, Cathay General Hospital, Taipei
| | - Te-Chun Hsieh
- Department of Nuclear Medicine and PET Center, China Medical University Hospital; ; Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung
| | - Chi-Lun Ko
- Department of Nuclear Medicine, National Taiwan University Hospital Yun-Lin Branch, Yun-Lin
| | - Ruoh-Fang Yen
- Department of Nuclear Medicine, National Taiwan University Hospital; ; Department of Radiology, National Taiwan University College of Medicine, Taipei, Taiwan
| |
Collapse
|
31
|
Clerc OF, Fuchs TA, Possner M, Vontobel J, Mikulicic F, Stehli J, Liga R, Benz DC, Gräni C, Pazhenkottil AP, Gaemperli O, Buechel RR, Kaufmann PA. Real-time respiratory triggered SPECT myocardial perfusion imaging using CZT technology: impact of respiratory phase matching between SPECT and low-dose CT for attenuation correction. Eur Heart J Cardiovasc Imaging 2016; 18:31-38. [DOI: 10.1093/ehjci/jew031] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2015] [Accepted: 02/04/2016] [Indexed: 01/10/2023] Open
|
32
|
Liu CJ, Wu YW, Ko KY, Chen YC, Cheng MF, Yen RF, Tzen KY. Incremental Diagnostic Performance of Combined Parameters in the Detection of Severe Coronary Artery Disease Using Exercise Gated Myocardial Perfusion Imaging. PLoS One 2015; 10:e0134485. [PMID: 26230651 PMCID: PMC4521811 DOI: 10.1371/journal.pone.0134485] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Accepted: 07/10/2015] [Indexed: 11/18/2022] Open
Abstract
Purpose Myocardial perfusion imaging (MPI) using gated single-photon emission tomography (gSPECT) may underestimate the severity of coronary artery disease (CAD). This study aimed to evaluate the significance of combined parameters derived from gSPECT, as well as treadmill stress test parameters, in the detection of severe CAD. Methods A total of 211 consecutive patients referred for exercise MPI between June 2011 and June 2013 (who received invasive coronary angiography within six months after MPI) were retrospectively reviewed. Exercise MPI was performed with Bruce protocol and 201Tl injected at peak exercise. Gated SPECT was performed using a cadmium-zinc-telluride camera and processed by QPS/QGS software. Perfusion defect abnormalities such as sum stress score (SSS); sum difference score, algorithm-derived total perfusion deficits, transient ischemic dilatation ratios of end-diastolic volumes and end-systolic volumes, post-stress changes in ejection fraction, and lung/heart ratio (LHR) were calculated. Treadmill parameters, including ST depression (STD) at the 1st and 3rd minutes of recovery stage (1’STD and 3’STD), maximal STD corrected by heart rate increment (ST/HR), heart rate decline in 1st and 3rd minutes of recovery stage, recovery heart rate ratio (HR ratio), systolic and mean blood pressure ratios (SBP ratio and MAP ratio) during recovery phase were recorded. Diagnostic performances of these parameters were analyzed with receiver operating characteristic (ROC) analysis and logistic regression for detection of left main (≥ 50%) or 3-vessel disease (all ≥ 70% luminal stenosis) on invasive angiography. Results Among various MPI and treadmill parameters used for detection of severe CAD, SSS and ST/HR had the highest AUC (0.78, 0.73, p = NS) and best cut-off values (SSS > 6, ST/HR > 17.39 10-2mV/bpm), respectively. By univariate logistic regression, all parameters except 1’HRR, 3’HRR, SBP and MAP ratios increased the odds ratio of severe CAD. Only increased L/H ratio, 3’STD, and HR ratio remained significant after multivariate regression. The predicted values of combined MPI and treadmill parameters (LHR, 3’STD, and HR ratio) gave the best ROC (AUC: 0.91) than any individual parameter or parameter combination. Conclusions Of all treadmill and gSPECT parameters, the combination of MPI and treadmill parameters can offer better diagnostic performance for severe CAD.
Collapse
Affiliation(s)
- Chia-Ju Liu
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Yen-Wen Wu
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
- Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan
- Department of Nuclear Medicine, Far-Eastern Memorial Hospital, New Taipei City, Taiwan
- Cardiology Division of Cardiovascular Medical Center, Far-Eastern Memorial Hospital, New Taipei City, Taiwan
- National Yang-Ming University School of Medicine, Taipei, Taiwan
- * E-mail:
| | - Kuan-Yin Ko
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Yi-Chieh Chen
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Mei-Fang Cheng
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Ruoh-Fang Yen
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| | - Kai-Yuan Tzen
- Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan
| |
Collapse
|