1
|
Kumar M, Pandey PS, Srivastava VK, Reddy MS, Gehlot A, Singh Y, Singh GK, Singh B. Two-dimensional Graphene/MoS2 vertical heterostructure for detection of hemoglobin concentration in blood samples. PLoS One 2024; 19:e0310166. [PMID: 39255261 PMCID: PMC11386459 DOI: 10.1371/journal.pone.0310166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Accepted: 08/26/2024] [Indexed: 09/12/2024] Open
Abstract
This study demonstrates the use of computational methods to simulate the molecular dynamics involved in hemoglobin concentration sensing, utilizing Material Studio and the TCAD Silvaco device simulator. A non-invasive and flexible Graphene/MoS2 heterostructure has been proposed for sensing hemoglobin concentration in blood samples. The findings reveal a notable shift in the wavelength-dependent refractive index and extinction coefficient, as well as significant changes in the absorption coefficient and reflectivity of the Graphene/MoS2 heterostructure in response to different hemoglobin concentrations, specifically within an approximate range of 0.3 μm to 1 μm. Moreover, the spectral response of the heterostructure demonstrates that at a particular wavelength of approximately 600 nm, a maximum response is obtained. This wavelength can be considered optimal for detecting various levels of hemoglobin using this heterostructure. The anticipated outcome is a comprehensive understanding of the fundamental principles, ultimately resulting in the development of an exceptionally sensitive platform for detecting hemoglobin concentration.
Collapse
Affiliation(s)
- Manoj Kumar
- MLR Institute of Technology, Hyderabad, India
| | - Purnendu Shekhar Pandey
- Department of Electronics and Communication Engineering, GL Bajaj Institute of Technology and Management, Greater Noida, U.P., India
| | | | - M Sudhakara Reddy
- Department of Physics & Electronics, JAIN (Deemed to be University), Bangalore, Karnataka, India
| | - Anita Gehlot
- Uttaranchal Institute of Technology, Uttaranchal University, Dehradun, India
| | - Yadvendra Singh
- Uttaranchal Institute of Technology, Uttaranchal University, Dehradun, India
| | | | - Balkeshwar Singh
- Department of Mechanical Engineering, Program of Manufacturing Engineering, Adama Science and Technology University, Adama, Ethiopia
| |
Collapse
|
2
|
Choudhary P, Singh VK, Dixit A. 2D-Bio-FETs for sensitive detection of cardiovascular diseases. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2024; 36:413004. [PMID: 38959912 DOI: 10.1088/1361-648x/ad5ee9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Accepted: 07/03/2024] [Indexed: 07/05/2024]
Abstract
The biosensing industry has seen exponential growth in the past decade. Impact of biosensors in the current scenario cannot be overlooked. Cardiovascular diseases (CvDs) have been recognized as one of the major causes for millions of deaths globally. This mortality can be minimized by early and accurate detection/diagnosis of CvDs with the help of biosensing devices. This also presents a global market opportunity for the development of biosensors for CvDs. A vast variety of biosensing methods and devices have been developed for this problem. Most of commercially available platforms for CvD detection rely on optical (fluorometric and colorimetric analysis) techniques using serum biomarkers since optical testing is the gold standard in medical diagnosis. Field effect transistors-based biosensors, termed as Bio-FETs, are the upcoming devices for blood or serum analyte detection due to excellent sensitivity, low operational voltage, handheld device structure and simple chip-based operation. Further, the discovery of two dimensional (2D) materials and their integration with conventional FETs has improved the overvoltage problem, sensitivity and strict operating conditions as compared to conventional FETs. Graphene-FETs based biosensing devices have been proven as promising candidates due to their attractive properties. Despite the severe threat of CvDs which has further increased in post-covid era, the Bio-FET sensor studies in literature are still rare. In this review, we aim to provide a comprehensive view of all the multidisciplinary concepts related to 2D-BioFETs for CvDs. A critical review of the different platforms has been covered with detailed discussions of related studies to provide a clear concept and present status of 2D-BioFETs based CvD biosensors.
Collapse
Affiliation(s)
- Piyush Choudhary
- Advanced Material and Device (AMAD) Laboratory, Department of Physics, Indian Institute of Technology Jodhpur, Karwar, Jodhpur, Rajasthan 342030, India
| | - Vijay K Singh
- Advanced Material and Device (AMAD) Laboratory, Department of Physics, Indian Institute of Technology Jodhpur, Karwar, Jodhpur, Rajasthan 342030, India
| | - Ambesh Dixit
- Advanced Material and Device (AMAD) Laboratory, Department of Physics, Indian Institute of Technology Jodhpur, Karwar, Jodhpur, Rajasthan 342030, India
| |
Collapse
|
3
|
Rabbani G, Ahmad E, Khan ME, Khan AU, Zamzami MA, Ahmad A, Ali SK, Bashiri AH, Zakri W. Synthesis of carbon nanotubes-chitosan nanocomposite and immunosensor fabrication for myoglobin detection: An acute myocardial infarction biomarker. Int J Biol Macromol 2024; 265:130616. [PMID: 38447842 DOI: 10.1016/j.ijbiomac.2024.130616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 03/02/2024] [Accepted: 03/02/2024] [Indexed: 03/08/2024]
Abstract
The use of single-walled carbon nanotubes (SWCNTs) in biomedical applications is limited due to their inability to disperse in aqueous solutions. In this study, dispersed -COOH functionalized CNTs with N-succinylated chitosan (CS), greatly increasing the water solubility of CNTs and forming a uniformly dispersed nanocomposite solution of CNTs@CS. Coupling reagent EDC/NHS was used as a linker with the -COOH groups present on the N-succinylated chitosan which significantly improved the affinity of the CNTs for biomolecules. Myoglobin (Mb) is a promising biomarker for the precise assessment of cardiovascular risk, type 2 diabetes, metabolic syndrome, hypertension and several types of cancer. A high level of Mb can be used to diagnose the mentioned pathogenic diseases. The CNTs@CS-FET demonstrates superior sensing performance for Mb antigen fortified in buffer, with a wide linear range of 1 to 4000 ng/mL. The detection limit of the developed Mb immunosensor was estimated to be 4.2 ng/mL. The novel CNTs@CS-FET immunosensor demonstrates remarkable capability in detecting Mb without being affected by interferences from nonspecific antigens. Mb spiked serum showed a recovery rate of 100.262 to 118.55 % indicating great promise for Mb detection in clinical samples. The experimental results confirmed that the CNTs@CS-FET immunosensor had excellent selectivity, reproducibility and storage stability.
Collapse
Affiliation(s)
- Gulam Rabbani
- IT-medical Fusion Center, 350-27 Gumidae-ro, Gumi-si, Gyeongbuk 39253, Republic of Korea.
| | - Ejaz Ahmad
- Department of Pathology, University of Michigan Medical School, Ann Arbor, MI 48109, United States of America
| | - Mohammad Ehtisham Khan
- Department of Chemical Engineering Technology, College of Applied Industrial Technology, Jazan University, Jazan 45142, Saudi Arabia.
| | - Anwar Ulla Khan
- Department of Electrical Engineering Technology, College of Applied Industrial Technology, Jazan University, Jazan 45142, Saudi Arabia
| | - Mazin A Zamzami
- Department of Biochemistry, Faculty of Science, King Abdulaziz University, Jeddah 21452, Saudi Arabia
| | - Abrar Ahmad
- Department of Biochemistry, Faculty of Science, King Abdulaziz University, Jeddah 21452, Saudi Arabia
| | - Syed Kashif Ali
- Department of Physical Sciences, Chemistry Division, College of Science, Jazan University, P.O. Box. 114, Jazan 45142, Kingdom of Saudi Arabia; Nanotechnology research unit, College of Science, Jazan University, P.O. Box. 114, Jazan 45142, Kingdom of Saudi Arabia
| | - Abdullateef H Bashiri
- Department of Mechanical Engineering, College of Engineering, Jazan University, P. O. Box 114, Jazan 45142, Saudi Arabia
| | - Waleed Zakri
- Department of Mechanical Engineering, College of Engineering, Jazan University, P. O. Box 114, Jazan 45142, Saudi Arabia
| |
Collapse
|
4
|
Meškinis Š, Gudaitis R, Vasiliauskas A, Guobienė A, Jankauskas Š, Stankevič V, Keršulis S, Stirkė A, Andriukonis E, Melo W, Vertelis V, Žurauskienė N. Biosensor Based on Graphene Directly Grown by MW-PECVD for Detection of COVID-19 Spike (S) Protein and Its Entry Receptor ACE2. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2373. [PMID: 37630958 PMCID: PMC10458353 DOI: 10.3390/nano13162373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Revised: 08/09/2023] [Accepted: 08/16/2023] [Indexed: 08/27/2023]
Abstract
Biosensors based on graphene field-effect transistors (G-FET) for detecting COVID-19 spike S protein and its receptor ACE2 were reported. The graphene, directly synthesized on SiO2/Si substrate by microwave plasma-enhanced chemical vapor deposition (MW-PECVD), was used for FET biosensor fabrication. The commercial graphene, CVD-grown on a copper substrate and subsequently transferred onto a glass substrate, was applied for comparison purposes. The graphene structure and surface morphology were studied by Raman scattering spectroscopy and atomic force microscope. Graphene surfaces were functionalized by an aromatic molecule PBASE (1-pyrenebutanoic acid succinimidyl ester), and subsequent immobilization of the receptor angiotensin-converting enzyme 2 (ACE2) was performed. A microfluidic system was developed, and transfer curves of liquid-gated FET were measured after each graphene surface modification procedure to investigate ACE2 immobilization by varying its concentration and subsequent spike S protein detection. The directly synthesized graphene FET sensitivity to the receptor ACE2, evaluated in terms of the Dirac voltage shift, exceeded the sensitivity of the transferred commercial graphene-based FET. The concentration of the spike S protein was detected in the range of 10 ag/mL up to 10 μg/mL by using a developed microfluidic system and measuring the transfer characteristics of the liquid-gated G-FETs. It was found that the shift of the Dirac voltage depends on the spike S concentration and was 27 mV with saturation at 10 pg/mL for directly synthesized G-FET biosensor, while for transferred G-FET, the maximal shift of 70 mV was obtained at 10 μg/mL with a tendency of saturation at 10 ng/mL. The detection limit as low as 10 ag/mL was achieved for both G-FETs. The sensitivity of the biosensors at spike S concentration of 10 pg/mL measured as relative current change at a constant gate voltage corresponding to the highest transconductance of the G-FETs was found at 5.6% and 8.8% for directly synthesized and transferred graphene biosensors, respectively. Thus, MW-PECVD-synthesized graphene-based biosensor demonstrating high sensitivity and low detection limit has excellent potential for applications in COVID-19 diagnostics.
Collapse
Affiliation(s)
- Šarunas Meškinis
- Institute of Materials Science, Kaunas University of Technology, K. Baršausko St. 59, LT-51423 Kaunas, Lithuania; (R.G.); (A.V.); (A.G.); (Š.J.)
| | - Rimantas Gudaitis
- Institute of Materials Science, Kaunas University of Technology, K. Baršausko St. 59, LT-51423 Kaunas, Lithuania; (R.G.); (A.V.); (A.G.); (Š.J.)
| | - Andrius Vasiliauskas
- Institute of Materials Science, Kaunas University of Technology, K. Baršausko St. 59, LT-51423 Kaunas, Lithuania; (R.G.); (A.V.); (A.G.); (Š.J.)
| | - Asta Guobienė
- Institute of Materials Science, Kaunas University of Technology, K. Baršausko St. 59, LT-51423 Kaunas, Lithuania; (R.G.); (A.V.); (A.G.); (Š.J.)
| | - Šarūnas Jankauskas
- Institute of Materials Science, Kaunas University of Technology, K. Baršausko St. 59, LT-51423 Kaunas, Lithuania; (R.G.); (A.V.); (A.G.); (Š.J.)
| | - Voitech Stankevič
- Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Saulėtekio Ave. 3, LT-10257 Vilnius, Lithuania; (V.S.); (S.K.); (A.S.); (E.A.); (W.M.); (V.V.); (N.Ž.)
| | - Skirmantas Keršulis
- Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Saulėtekio Ave. 3, LT-10257 Vilnius, Lithuania; (V.S.); (S.K.); (A.S.); (E.A.); (W.M.); (V.V.); (N.Ž.)
| | - Arūnas Stirkė
- Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Saulėtekio Ave. 3, LT-10257 Vilnius, Lithuania; (V.S.); (S.K.); (A.S.); (E.A.); (W.M.); (V.V.); (N.Ž.)
| | - Eivydas Andriukonis
- Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Saulėtekio Ave. 3, LT-10257 Vilnius, Lithuania; (V.S.); (S.K.); (A.S.); (E.A.); (W.M.); (V.V.); (N.Ž.)
| | - Wanessa Melo
- Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Saulėtekio Ave. 3, LT-10257 Vilnius, Lithuania; (V.S.); (S.K.); (A.S.); (E.A.); (W.M.); (V.V.); (N.Ž.)
| | - Vilius Vertelis
- Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Saulėtekio Ave. 3, LT-10257 Vilnius, Lithuania; (V.S.); (S.K.); (A.S.); (E.A.); (W.M.); (V.V.); (N.Ž.)
| | - Nerija Žurauskienė
- Department of Functional Materials and Electronics, Center for Physical Sciences and Technology, Saulėtekio Ave. 3, LT-10257 Vilnius, Lithuania; (V.S.); (S.K.); (A.S.); (E.A.); (W.M.); (V.V.); (N.Ž.)
| |
Collapse
|