1
|
Yakamercan E, Aygün A, Simsek H. Antibiotic ciprofloxacin removal from aqueous solutions by electrochemically activated persulfate process: Optimization, degradation pathways, and toxicology assessment. J Environ Sci (China) 2024; 143:85-98. [PMID: 38644026 DOI: 10.1016/j.jes.2023.08.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 08/13/2023] [Accepted: 08/13/2023] [Indexed: 04/23/2024]
Abstract
Ciprofloxacin (CIP) is a commonly used antibiotic in the fluoroquinolone group and is widely used in medical and veterinary medicine disciplines to treat bacterial infections. When CIP is discharged into the sewage system, it cannot be removed by a conventional wastewater treatment plant because of its recalcitrant characteristics. In this study, boron-doped diamond anode and persulfate were used to degrade CIP in an aquatic solution by creating an electrochemically activated persulfate (EAP) process. Iron was added to the system as a coactivator and the process was called EAP+Fe. The effects of independent variables, including pH, Fe2+, persulfate concentration, and electrolysis time on the system were optimized using the response surface methodology. The results showed that the EAP+Fe process removed 94% of CIP under the following optimum conditions: A pH of 3, persulfate/Fe2+ concentration of 0.4 mmol/L, initial CIP concentration 30 mg/L, and electrolysis time of 12.64 min. CIP removal efficiency was increased from 65.10% to 94.35% by adding Fe2+ as a transition metal. CIP degradation products, 7 pathways, and 78 intermediates of CIP were studied, and three of those intermediates (m/z 298, 498, and 505) were reported. The toxicological analysis based on toxicity estimation software results indicated that some degradation products of CIP were toxic to targeted animals, including fathead minnow, Daphnia magna, Tetrahymena pyriformis, and rats. The optimum operation costs were similar in EAP and EAP+Fe processes, approximately 0.54 €/m3.
Collapse
Affiliation(s)
- Elif Yakamercan
- Environmental Engineering Department, Bursa Technical University, Bursa, Turkey
| | - Ahmet Aygün
- Environmental Engineering Department, Bursa Technical University, Bursa, Turkey.
| | - Halis Simsek
- Agricultural and Biological Engineering Department, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
2
|
Vaz T, Quina MMJ, Martins RC, Gomes J. Olive mill wastewater treatment strategies to obtain quality water for irrigation: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 931:172676. [PMID: 38670378 DOI: 10.1016/j.scitotenv.2024.172676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 04/19/2024] [Accepted: 04/20/2024] [Indexed: 04/28/2024]
Abstract
The olive mill industry is a relevant sector in the economy of Mediterranean countries, while it involves high consumption of water and the production of effluents with high environmental impact. The efficient treatment of olive mill wastewater (OMW) is of high relevance, particularly for these countries. Climate changes are leading to increasing periods of droughts, and water recovery from polluted streams is essential to ensure the sustainability of this scarce resource. A combination of various technologies involving physical, chemical, and biological processes has been developed for OMW treatment. However, the treatments studied have limitations such as the operation costs, difficulty of industrial scale-up, and the fact that the vast majority do not lead to suitable treated water for discharge/reuse. As such, it is urgent to develop a solution capable of efficiently treating this effluent, overcoming the disadvantages of existing processes to convert OMW from a serious environmental problem into a valuable source of water and nutrients. In this review, several studies based on the OMW treatment are critically discussed, from conventional approaches such as the physical (e.g. centrifugation, filtration, and adsorption) and biological (anaerobic digestion and anaerobic co-digestion) processes, to the most recent technologies such as advanced membrane filtration, advanced oxidation processes (AOPs) and sulfate radical based AOPs (SR-AOPs). Due to the complexity of the effluent, OMW cannot be efficiently treated by a single process, requiring a sequence of technologies before reaching the required characteristics for discharge into water courses or use in crop irrigation. Reviewing the published results in this matter, it seems that the sequence of processes encompassing ozonation, anaerobic digestion, and SR-AOPs could be the ideal combination for this purpose. However, membrane technologies may be necessary in the final stage of treatment so that the effluent meets legal discharge or irrigation limits.
Collapse
Affiliation(s)
- Telma Vaz
- University of Coimbra, CERES, Department of Chemical Engineering, Faculty of Sciences and Technology, Rua Sílvio Lima, Polo II, 3030-790 Coimbra, Portugal
| | - Margarida M J Quina
- University of Coimbra, CERES, Department of Chemical Engineering, Faculty of Sciences and Technology, Rua Sílvio Lima, Polo II, 3030-790 Coimbra, Portugal
| | - Rui C Martins
- University of Coimbra, CERES, Department of Chemical Engineering, Faculty of Sciences and Technology, Rua Sílvio Lima, Polo II, 3030-790 Coimbra, Portugal
| | - João Gomes
- University of Coimbra, CERES, Department of Chemical Engineering, Faculty of Sciences and Technology, Rua Sílvio Lima, Polo II, 3030-790 Coimbra, Portugal..
| |
Collapse
|
3
|
Yazici Guvenc S, Tunc S. Alternative treatment of olive mill wastewater by combined sulfate radical-based advanced electrocoagulation processes. WATER ENVIRONMENT RESEARCH : A RESEARCH PUBLICATION OF THE WATER ENVIRONMENT FEDERATION 2023; 95:e10951. [PMID: 38031510 DOI: 10.1002/wer.10951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 10/29/2023] [Accepted: 11/03/2023] [Indexed: 12/01/2023]
Abstract
The aim of this study is to investigate the performance of advanced electrocoagulation (EC) process for the treatment of olive mill wastewater. In EC process, iron plates were used as electrodes, and peroxydisulfate (PS) and peroxymonosulfate (PMS) were added as oxidants. The effects of the initial pH value, current density, oxidant dose, and electrolysis time were optimized for pollutant removal from olive mill wastewater by EC-PS and EC-PMS processes. Control experiments showed that addition of oxidants to the conventional EC process increased the pollutant removal efficiency. Classical optimization method was used to determine optimum conditions, which were initial pH 4, current density 40 mA/cm2 , oxidant dose 5 g/L, and electrolysis time 30 min for both processes. Under these conditions, EC-PS and EC-PMS processes achieved 50.5% and 48.9% chemical oxygen demand (COD), 93.8% and 89.3% total phenol, 87.7% and 83% UV254 , and 74.5% and 64.1% total suspended solid removal efficiencies. Quenching experiments were performed to determine the dominant radical species participating in the processes. It was observed that hydroxyl and sulfate radicals were involved in both processes but hydroxyl radicals were more active. Specific energy consumption was calculated as 5.90 kWh/kg COD for EC process, 4.95 kWh/kg COD for EC-PS process, and 5.20 kWh/kg COD for EC-PMS process. The organic removal/sludge ratio of EC-PS process was found to be higher with 17.5 g/L value. Although the application of EC-PS and EC-PMS processes alone is insufficient to meet the discharge limits, they have been found to be effective in olive mill wastewater treatment. PRACTITIONER POINTS: Peroxydisulfate (PS) and peroxymonosulfate (PMS)-based advanced electrocoagulation (EC) was used in olive mill wastewater treatment. 50.5% chemical oxygen demand (COD), 93.8% TP, 87.7% UV254 , and 74.5% TSS removals were achieved by EC-PS. 48.9% COD, 89.3% TP, 83% UV254 , and 64.1% TSS removals were obtained by EC-PMS. Hydroxyl and sulfate radicals were involved in both processes.
Collapse
Affiliation(s)
- Senem Yazici Guvenc
- Faculty of Civil Engineering, Department of Environmental Engineering, Yildiz Technical University, Esenler, Istanbul, Turkey
| | - Sinan Tunc
- Faculty of Civil Engineering, Department of Environmental Engineering, Yildiz Technical University, Esenler, Istanbul, Turkey
| |
Collapse
|
4
|
Selective denitrification of simulated oily wastewater by oxidation using Janus-structured carbon nanotubes. Catal Today 2023. [DOI: 10.1016/j.cattod.2023.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
5
|
Domingues E, Silva MJ, Vaz T, Gomes J, Martins RC. Sulfate radical based advanced oxidation processes for agro-industrial effluents treatment: A comparative review with Fenton's peroxidation. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 832:155029. [PMID: 35390368 DOI: 10.1016/j.scitotenv.2022.155029] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 03/30/2022] [Accepted: 03/31/2022] [Indexed: 06/14/2023]
Abstract
Agro-industrial wastewater management becomes a major task while environmental regulations are becoming stricter worldwide. Agro-industrial wastewaters are known by high content of organic pollutants that cause an adverse effect on the water bodies. Industries are looking for efficient, easy-to-use and affordable treatment processes. Sulfate radical based advanced oxidation processes (S-AOPs) are arising as suitable alternatives for agro-industrial effluents treatment. In this review, the major findings regarding the application of this technology for real agro-industrial wastewater depuration are discussed. Moreover, these technologies are compared as an alternative to Fenton's process, which is a widely studied advanced oxidation process and with high efficiency in the treatment of agro-industrial effluents. The studies already carried out are promising, but there is still a great lack of studies in this area and using this technique.
Collapse
Affiliation(s)
- Eva Domingues
- University of Coimbra, CIEPQPF - Chemical Engineering Processes and Forest Products Research Center, Department of Chemical Engineering, Faculty of Sciences and Technology, Rua Sílvio Lima, 3030-790 Coimbra, Portugal.
| | - Maria João Silva
- University of Coimbra, CIEPQPF - Chemical Engineering Processes and Forest Products Research Center, Department of Chemical Engineering, Faculty of Sciences and Technology, Rua Sílvio Lima, 3030-790 Coimbra, Portugal
| | - Telma Vaz
- University of Coimbra, CIEPQPF - Chemical Engineering Processes and Forest Products Research Center, Department of Chemical Engineering, Faculty of Sciences and Technology, Rua Sílvio Lima, 3030-790 Coimbra, Portugal
| | - João Gomes
- University of Coimbra, CIEPQPF - Chemical Engineering Processes and Forest Products Research Center, Department of Chemical Engineering, Faculty of Sciences and Technology, Rua Sílvio Lima, 3030-790 Coimbra, Portugal
| | - Rui C Martins
- University of Coimbra, CIEPQPF - Chemical Engineering Processes and Forest Products Research Center, Department of Chemical Engineering, Faculty of Sciences and Technology, Rua Sílvio Lima, 3030-790 Coimbra, Portugal
| |
Collapse
|
6
|
Görmez Ö, Akay S, Gözmen B, Kayan B, Kalderis D. Degradation of emerging contaminant coumarin based on anodic oxidation, electro-Fenton and subcritical water oxidation processes. ENVIRONMENTAL RESEARCH 2022; 208:112736. [PMID: 35041815 DOI: 10.1016/j.envres.2022.112736] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Revised: 01/04/2022] [Accepted: 01/12/2022] [Indexed: 06/14/2023]
Abstract
The degradation of emerging contaminant coumarin was separately investigated in anodic, electro-Fenton and subcritical water oxidation processes. With respect to the anodic and electro-Fenton oxidation, the influence of constant current, treatment time and initial concentration of coumarin was studied. Regarding subcritical water oxidation, the effect of the oxidant concentration, temperature, treatment time and initial coumarin concentration was investigated. In anodic and electro-Fenton oxidation processes, coumarin degradation proceeded in a similar manner, achieving 99% degradation, after 180 min at a constant current of 200 mA. In both set-ups, further increasing the applied current lowered the degradation efficiency due to the formation of by-products and the increasing occurrence of side-reactions. The highest degradation of 88% was achieved in subcritical conditions, specifically at 200 °C, using 150 mM H2O2 and after 37.5 min of treatment. Under subcritical conditions, temperature was the most prominent parameter, followed by the H2O2 concentration. Under all methodologies, increasing treatment time had a small positive effect on coumarin degradation, indicating that time is not the most influential parameter. A comparison of the three methodologies in terms of performance as well as energy consumption and simplicity of operation highlighted the advantages of subcritical water oxidation.
Collapse
Affiliation(s)
- Özkan Görmez
- Department of Chemistry, Arts and Science Faculty, Mersin University, Mersin, Turkey.
| | - Sema Akay
- Department of Chemistry, Arts and Science Faculty, Aksaray University, Aksaray, Turkey.
| | - Belgin Gözmen
- Department of Chemistry, Arts and Science Faculty, Mersin University, Mersin, Turkey.
| | - Berkant Kayan
- Department of Chemistry, Arts and Science Faculty, Aksaray University, Aksaray, Turkey.
| | - Dimitrios Kalderis
- Department of Electronic Engineering, Hellenic Mediterranean University, Chania, 73100, Crete, Greece.
| |
Collapse
|
7
|
Synergistic antimicrobial activity of ε-polylysine, chestnut extract, and cinnamon extract against Staphylococcus aureus. Food Sci Biotechnol 2022; 31:607-615. [PMID: 35529685 PMCID: PMC9033916 DOI: 10.1007/s10068-022-01065-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 03/02/2022] [Accepted: 03/03/2022] [Indexed: 11/04/2022] Open
Abstract
A mixed natural preservative composed of ε-polylysine (ε-PL), chestnut 70% ethanol extract (NE), and cinnamon hydrothermal extract (CW), was investigated for the reduction of Staphylococcus aureus. The minimum inhibitory concentration (MIC) and minimum bacterial concentration (MBC) of seven natural extracts were investigated against a cocktail of three strains of S. aureus (ATCC 25923, ATCC 33591, and ATCC 33594). Three important factors (ε-PL, NE, and CW) were selected by using the Plackett-Burman (PB) design for the response surface model (P < 0.001). Following a central composite design, S. aureus were treated with mixtures of natural preservatives that included ε-PL, NE, and CW. The MIC and MBC of ε-PL and the natural extracts and ranged from 1 to 16 mg/mL (R2 = 0.9857). The mixed natural preservative presented a synergistic antibacterial effect, at the optimum point. These results suggest that mixed natural preservatives of ε-PL, NE, and CW can lower the economic cost of food processing.
Collapse
|
8
|
Evaluation of the Activation Procedure on Oxone Efficiency for Synthetic Olive Mill Wastewater Treatment. Catalysts 2022. [DOI: 10.3390/catal12030291] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Wastewater from the olive oil industry is an environmental problem which is growing in the Mediterranean region. Presence of phenolic compounds and high organic matter load are characteristics of this effluent that make it difficult to treat. In this study, the applicability of sulfate radical based advanced oxidation processes (SRbAOPs), using peroxymonosulfate (PMS) as oxidant, was evaluated in the treatment of synthetic olive mill wastewater (OMW). Different procedures for PMS activation were studied such as activation by Fe(II), radiation (visible and UV-A) and ultrasounds. The operation conditions were optimized by testing pH values, Fe(II) and PMS loads. At optimal conditions ([PMS] = 1600 mg/L, [Fe2+] = 700 mg/L and pH = 5) 60 ± 2% COD removal was achieved. This process shows to be selective since complete degradation of 3,4,5-trimetoxybenzoic acid was obtained after 3 min of reaction. The addition of light, PMS/LED/Fe(II) and PMS/UV-A/Fe(II), did not increase the efficiency of organic matter removal, with 56 ± 2% and 58 ± 1% of COD removal, respectively, comparatively to PMS/Fe(II) (60 ± 2%). PMS activated by ultrasounds led to 52 ± 3% and 23 ± 2% removal of phenolic compounds and COD, respectively, after 60 min. Toxicity tests using Lepidium sativum showed that treatment with PMS/UV-A led to a treated sample with mild inhibition of plant growth.
Collapse
|
9
|
Kamyab H, Yuzir MA, Al-Qaim FF, Purba LDA, Riyadi FA. Application of Box-Behnken design to mineralization and color removal of palm oil mill effluent by electrocoagulation process. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 30:10.1007/s11356-021-16197-z. [PMID: 34480301 DOI: 10.1007/s11356-021-16197-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 08/24/2021] [Indexed: 06/13/2023]
Abstract
In this study, palm oil mill effluent (POME) was treated using electrocoagulation, whereby the influencing factors including voltage, electrolysis time, and electrolyte amount were optimized to achieve the highest chemical oxygen demand (COD) and color removal efficiencies. Graphite was selected as electrode material due to its performance better compared to aluminum and copper. Response surface methodology (RSM) was carried out for optimization of the electrocoagulation operating parameters. The best model obtained using Box-Behnken design (BBD) were quadratic for COD removal (R2 = 0.9844), color reduction (R2 = 0.9412), and oil and grease removal (R2 = 0.9724). The result from the analysis of variance (ANOVA) was obtained to determine the relationship between factors and treatment efficiencies. The experimental results under optimized conditions such as voltage 14, electrolysis time of 3 h, and electrolyte amount of 13.41 g/L show that the electrocoagulation process effectively reduced the COD (56%), color (65%), and oil and grease (99%) of the POME treatment. Graphical abstract.
Collapse
Affiliation(s)
- Hesam Kamyab
- Department of Chemical and Environmental Engineering (ChEE), Malaysia-Japan International Institute of Technology (MJIIT), Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100, Kuala Lumpur, Malaysia.
| | - Muhammad Ali Yuzir
- Department of Chemical and Environmental Engineering (ChEE), Malaysia-Japan International Institute of Technology (MJIIT), Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100, Kuala Lumpur, Malaysia.
| | - Fouad Fadhil Al-Qaim
- Department of Chemistry, Faculty of Sciences for Women, University of Babylon, Hilla, Iraq
| | - Laila Dina Amalia Purba
- Department of Chemical and Environmental Engineering (ChEE), Malaysia-Japan International Institute of Technology (MJIIT), Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100, Kuala Lumpur, Malaysia
| | - Fatimah Azizah Riyadi
- Department of Chemical and Environmental Engineering (ChEE), Malaysia-Japan International Institute of Technology (MJIIT), Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100, Kuala Lumpur, Malaysia
| |
Collapse
|
10
|
Electro-Persulfate Processes for the Treatment of Complex Wastewater Matrices: Present and Future. Molecules 2021; 26:molecules26164821. [PMID: 34443408 PMCID: PMC8401330 DOI: 10.3390/molecules26164821] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 08/04/2021] [Accepted: 08/06/2021] [Indexed: 11/16/2022] Open
Abstract
Complex wastewater matrices present a major environmental concern. Besides the biodegradable organics, they may contain a great variety of toxic chemicals, heavy metals, and other xenobiotics. The electrochemically activated persulfate process, an efficient way to generate sulfate radicals, has been widely applied to the degradation of such complex effluents with very good results. This review presents the fundamentals of the electro-persulfate processes, highlighting the advantages and limitations, followed by an exhaustive evaluation on the application of this process for the treatment of complex industrial effluents. An overview of the main relevant experimental parameters/details and their influence on the organic load removal is presented and discussed, having in mind the application of these technologies at an industrial scale. Finally, the future perspectives for the application of the electro-persulfate processes in the treatment of complex wastewater matrices is outlined.
Collapse
|
11
|
Ma D, Yi H, Lai C, Liu X, Huo X, An Z, Li L, Fu Y, Li B, Zhang M, Qin L, Liu S, Yang L. Critical review of advanced oxidation processes in organic wastewater treatment. CHEMOSPHERE 2021; 275:130104. [PMID: 33984911 DOI: 10.1016/j.chemosphere.2021.130104] [Citation(s) in RCA: 199] [Impact Index Per Article: 66.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Revised: 02/22/2021] [Accepted: 02/23/2021] [Indexed: 05/19/2023]
Abstract
With the development of industrial society, organic wastewater produced by industrial manufacturing has caused many environmental problems. The vast majority of organic pollutants in water bodies are persistent in the environment, posing a threat to human and animal health. Therefore, efficient treatment methods for highly concentrated organic wastewater are urgently needed. Advanced oxidation processes (AOPs) are widely noticed in the area of treating organic wastewater. Compared with other chemical methods, AOPs have the characteristics of high oxidation efficiency and no secondary pollution. In this paper, the mechanisms, advantages, and limitations of AOPs are comprehensively reviewed. Besides, the basic principles of combining different AOPs to enhance the treatment efficiency are described. Furthermore, the applications of AOPs in various wastewater treatments, such as oily wastewater, dyeing wastewater, pharmaceutical wastewater, and landfill leachate, are also presented. Finally, we conclude that the main direction in the future of AOPs are the modification of catalysts and the optimization of operating parameters, with the challenges focusing on industrial applications.
Collapse
Affiliation(s)
- Dengsheng Ma
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| | - Huan Yi
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| | - Cui Lai
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China.
| | - Xigui Liu
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| | - Xiuqin Huo
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| | - Ziwen An
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| | - Ling Li
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| | - Yukui Fu
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| | - Bisheng Li
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| | - Mingming Zhang
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| | - Lei Qin
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| | - Shiyu Liu
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| | - Lu Yang
- College of Environmental Science and Engineering, Hunan University, Changsha, Hunan, 410082, China; Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha, Hunan, 410082, China
| |
Collapse
|
12
|
Varank G, Yazici Guvenc S, Demir A, Kavan N, Donmez N, Onen ZT. Modeling and optimizing electro-persulfate processes using Fe and Al electrodes for paper industry wastewater treatment. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2020; 81:345-357. [PMID: 32333667 DOI: 10.2166/wst.2020.115] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In this study, the treatment of paper industry wastewaters by the electrocoagulation (EC) process with a strong oxidant, persulfate addition, was investigated. Persulfate was activated by dissolution of Fe and Al from electrodes during the process. Central composite design method, being one of the response surface methods, was applied for the optimization of process parameters and the development of a mathematical model for chemical oxygen demand (COD) removal from paper industry wastewaters. The effects of S2O8 -2/COD ratio, current, pH, and reaction time, being the variables of process, were assessed on the efficiency of contaminant removal. For COD removal in EC processes in which Fe and Al electrodes were used, the model's correlation coefficients (R2) were determined as 90.14% and 87.46%, respectively. As the result of experimental study actualized under optimum conditions determined by the model in order to obtain maximum contaminant removal, COD removal efficiencies were determined as 63.5% and 72.8% respectively for the Fe electrode (S2O8 -2/COD ratio: 1.25, current: 4.14 A, pH: 6, and reaction time: 5 minutes), and the Al electrode (S2O8 -2/COD ratio: 0.5, current: 4.25 A, pH: 7.25, and reaction time: 25 minutes). Electro-activated persulfate process is an appropriate treatment alternative for COD removal from paper industry wastewaters.
Collapse
Affiliation(s)
- Gamze Varank
- Department of Environmental Engineering, Yıldız Technical University, Davutpasa Campus, Esenler, Istanbul 34220, Turkey E-mail: ;
| | - Senem Yazici Guvenc
- Department of Environmental Engineering, Yıldız Technical University, Davutpasa Campus, Esenler, Istanbul 34220, Turkey E-mail: ;
| | - Ahmet Demir
- Department of Environmental Engineering, Yıldız Technical University, Davutpasa Campus, Esenler, Istanbul 34220, Turkey E-mail: ;
| | - Nihal Kavan
- Department of Environmental Engineering, Yıldız Technical University, Davutpasa Campus, Esenler, Istanbul 34220, Turkey E-mail: ;
| | - Nurten Donmez
- Department of Environmental Engineering, Yıldız Technical University, Davutpasa Campus, Esenler, Istanbul 34220, Turkey E-mail: ;
| | - Zeynep Tugce Onen
- Department of Environmental Engineering, Yıldız Technical University, Davutpasa Campus, Esenler, Istanbul 34220, Turkey E-mail: ;
| |
Collapse
|