Biccirè FG, Mannhart D, Kakizaki R, Windecker S, Räber L, Siontis GCM. Automatic assessment of atherosclerotic plaque features by intracoronary imaging: a scoping review. Front Cardiovasc Med 2024; 11:1332925. [PMID: 38742173 PMCID: PMC11090039 DOI: 10.3389/fcvm.2024.1332925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 04/01/2024] [Indexed: 05/16/2024] Open
Abstract
Background The diagnostic performance and clinical validity of automatic intracoronary imaging (ICI) tools for atherosclerotic plaque assessment have not been systematically investigated so far. Methods We performed a scoping review including studies on automatic tools for automatic plaque components assessment by means of optical coherence tomography (OCT) or intravascular imaging (IVUS). We summarized study characteristics and reported the specifics and diagnostic performance of developed tools. Results Overall, 42 OCT and 26 IVUS studies fulfilling the eligibility criteria were found, with the majority published in the last 5 years (86% of the OCT and 73% of the IVUS studies). A convolutional neural network deep-learning method was applied in 71% of OCT- and 34% of IVUS-studies. Calcium was the most frequent plaque feature analyzed (26/42 of OCT and 12/26 of IVUS studies), and both modalities showed high discriminatory performance in testing sets [range of area under the curve (AUC): 0.91-0.99 for OCT and 0.89-0.98 for IVUS]. Lipid component was investigated only in OCT studies (n = 26, AUC: 0.82-0.86). Fibrous cap thickness or thin-cap fibroatheroma were mainly investigated in OCT studies (n = 8, AUC: 0.82-0.94). Plaque burden was mainly assessed in IVUS studies (n = 15, testing set AUC reported in one study: 0.70). Conclusion A limited number of automatic machine learning-derived tools for ICI analysis is currently available. The majority have been developed for calcium detection for either OCT or IVUS images. The reporting of the development and validation process of automated intracoronary imaging analyses is heterogeneous and lacks critical information. Systematic Review Registration Open Science Framework (OSF), https://osf.io/nps2b/.Graphical AbstractCentral Illustration.
Collapse
Affiliation(s)
| | | | | | | | | | - George C. M. Siontis
- Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland
| |
Collapse
|
2
|
Neleman T, Khachabi J, Jonker H, Rademaker‐Havinga T, Spitzer E, Daemen J. Validation of a simplified intravascular ultrasound core lab analysis method in stented coronary arteries. Catheter Cardiovasc Interv 2022; 100:481-491. [PMID: 35811460 PMCID: PMC9795929 DOI: 10.1002/ccd.30321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Accepted: 06/04/2022] [Indexed: 12/30/2022]
Abstract
OBJECTIVES To validate a simplified core laboratory intravascular ultrasound (IVUS) analysis method based on frames with visually determined minimal lumen areas (MLAs) as compared with a comprehensive (per frame) analysis method. BACKGROUND IVUS-guided percutaneous coronary intervention has proven to be superior to angiography-guided stenting. In clinical practice, cross-sections with visually determined MLA are measured to determine lesion severity or minimal stent area (MSA), however, its accuracy has not been compared with a comprehensive per frame analysis method. METHODS A total of 50 stented coronary segments of anonymized core lab datasets were analyzed using a comprehensive analysis method and reanalyzed by two core lab analysts using the simplified method including a maximum of seven frames to be analyzed (the visually determined MSA, the first and last frame, and the MLA of each reference segment). The main parameters of interest were MSA, MLA in the reference segments, and plaque burden. RESULTS The simplified method showed moderate agreement for measurement of the proximal MLA (7.51 ± 2.52 vs. 6.32 ± 1.88 mm2 , intraclass correlation coefficient [ICC] = 0.73), good agreement for the distal MLA (5.41 ± 1.85 vs. 5.11 ± 1.38 mm2 , ICC = 0.84) and plaque burden proximal (0.49 ± 0.12 vs. 0.50 ± 0.11, ICC = 0.88), and excellent agreement for the MSA (5.35 ± 1.05 vs. 5.32 ± 0.99 mm2 , ICC = 0.94) and plaque burden distal (0.47 ± 0.14 vs. 0.47 ± 0.12, ICC = 0.92), when compared with the comprehensive analysis method. Inter- and intraobserver analysis revealed good-to-excellent agreement for all parameters. CONCLUSIONS Measuring poststenting IVUS cross-sections with visually determined MLAs by experienced core lab analysts is an accurate and reproducible method to identify MLAs.
Collapse
Affiliation(s)
- Tara Neleman
- Department of CardiologyThoraxcenter, Erasmus University Medical CenterRotterdamThe Netherlands
| | - Jamal Khachabi
- Cardialysis, Clinical Trial Management and Core LaboratoriesRotterdamThe Netherlands
| | - Hans Jonker
- Cardialysis, Clinical Trial Management and Core LaboratoriesRotterdamThe Netherlands
| | | | - Ernest Spitzer
- Department of CardiologyThoraxcenter, Erasmus University Medical CenterRotterdamThe Netherlands,Cardialysis, Clinical Trial Management and Core LaboratoriesRotterdamThe Netherlands
| | - Joost Daemen
- Department of CardiologyThoraxcenter, Erasmus University Medical CenterRotterdamThe Netherlands,Cardialysis, Clinical Trial Management and Core LaboratoriesRotterdamThe Netherlands
| |
Collapse
|
3
|
Gerbaud E, Weisz G, Tanaka A, Kashiwagi M, Shimizu T, Wang L, Souza C, Bouma BE, Suter MJ, Shishkov M, Ughi GJ, Halpern EF, Rosenberg M, Waxman S, Moses JW, Mintz GS, Maehara A, Tearney GJ. Multi-laboratory inter-institute reproducibility study of IVOCT and IVUS assessments using published consensus document definitions. Eur Heart J Cardiovasc Imaging 2015; 17:756-64. [PMID: 26377904 DOI: 10.1093/ehjci/jev229] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2015] [Accepted: 08/26/2015] [Indexed: 10/23/2022] Open
Abstract
AIMS The aim of this study was to investigate the reproducibility of intravascular optical coherence tomography (IVOCT) assessments, including a comparison to intravascular ultrasound (IVUS). Intra-observer and inter-observer variabilities of IVOCT have been previously described, whereas inter-institute reliability in multiple laboratories has never been systematically studied. METHODS AND RESULTS In 2 independent laboratories with intravascular imaging expertise, 100 randomized matched data sets of IVOCT and IVUS images were analysed by 4 independent observers according to published consensus document definitions. Intra-observer, inter-observer, and inter-institute variabilities of IVOCT qualitative and quantitative measurements vs. IVUS measurements were assessed. Minor inter- and intra-observer variability of both imaging techniques was observed for detailed qualitative and geometric analysis, except for inter-observer mixed plaque identification on IVUS (κ = 0.70) and for inter-observer fibrous cap thickness measurement reproducibility on IVOCT (ICC = 0.48). The magnitude of inter-institute measurement differences for IVOCT was statistically significantly less than that for IVUS concerning lumen cross-sectional area (CSA), maximum and minimum lumen diameters, stent CSA, and maximum and minimum stent diameters (P < 0.001, P < 0.001, P < 0.001, P = 0.02, P < 0.001, and P = 0.01, respectively). Minor inter-institute measurement variabilities using both techniques were also found for plaque identification. CONCLUSION In the measurement of lumen CSA, maximum and minimum lumen diameters, stent CSA, and maximum and minimum stent diameters by analysts from two different laboratories, reproducibility of IVOCT was more consistent than that of IVUS.
Collapse
Affiliation(s)
- Edouard Gerbaud
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, BHX604A, Boston, MA 02114, USA
| | - Giora Weisz
- Columbia University Medical Center, New York, NY, USA Cardiovascular Research Foundation, New York, NY, USA
| | - Atsushi Tanaka
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, BHX604A, Boston, MA 02114, USA
| | - Manabu Kashiwagi
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, BHX604A, Boston, MA 02114, USA
| | - Takehisa Shimizu
- Columbia University Medical Center, New York, NY, USA Cardiovascular Research Foundation, New York, NY, USA
| | - Lin Wang
- Columbia University Medical Center, New York, NY, USA Cardiovascular Research Foundation, New York, NY, USA
| | - Christiano Souza
- Columbia University Medical Center, New York, NY, USA Cardiovascular Research Foundation, New York, NY, USA
| | - Brett E Bouma
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, BHX604A, Boston, MA 02114, USA
| | - Melissa J Suter
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, BHX604A, Boston, MA 02114, USA
| | - Milen Shishkov
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, BHX604A, Boston, MA 02114, USA
| | - Giovanni J Ughi
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, BHX604A, Boston, MA 02114, USA
| | - Elkan F Halpern
- Institute for Technology Assessment, Massachusetts General Hospital, Boston, MA, USA
| | - Mireille Rosenberg
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, BHX604A, Boston, MA 02114, USA
| | - Sergio Waxman
- Department of Cardiology, Lahey Clinic Medical Center, Burlington, MA, USA
| | - Jeffrey W Moses
- Columbia University Medical Center, New York, NY, USA Cardiovascular Research Foundation, New York, NY, USA
| | - Gary S Mintz
- Columbia University Medical Center, New York, NY, USA Cardiovascular Research Foundation, New York, NY, USA
| | - Akiko Maehara
- Columbia University Medical Center, New York, NY, USA Cardiovascular Research Foundation, New York, NY, USA
| | - Guillermo J Tearney
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, BHX604A, Boston, MA 02114, USA Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA, USA Department of Pathology, Harvard Medical School and Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
4
|
Brugaletta S, Cola C, Martin-Yuste V, Vilahur G, Oriol J, Padro T, Guerra JM, Borras R, Badimon L, Sabate M. Qualitative and quantitative accuracy of ultrasound-based virtual histology for detection of necrotic core in human coronary arteries. Int J Cardiovasc Imaging 2014; 30:469-76. [DOI: 10.1007/s10554-014-0372-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2013] [Accepted: 01/15/2014] [Indexed: 01/15/2023]
|
5
|
Jamil Z, Tearney G, Bruining N, Sihan K, van Soest G, Ligthart J, van Domburg R, Bouma B, Regar E. Interstudy reproducibility of the second generation, Fourier domain optical coherence tomography in patients with coronary artery disease and comparison with intravascular ultrasound: a study applying automated contour detection. Int J Cardiovasc Imaging 2012; 29:39-51. [PMID: 22639296 PMCID: PMC3550705 DOI: 10.1007/s10554-012-0067-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2011] [Accepted: 05/04/2012] [Indexed: 11/28/2022]
Abstract
Recently, Fourier domain OCT (FD-OCT) has been introduced for clinical use. This approach allows in vivo, high resolution (15 micron) imaging with very fast data acquisition, however, it requires brief flushing of the lumen during imaging. The reproducibility of such fast data acquisition under intracoronary flush application is poorly understood. To assess the inter-study variability of FD-OCT and to compare lumen morphometry to the established invasive imaging method, IVUS. 18 consecutive patients with coronary artery disease scheduled for PCI were included. In each target vessel a FD-OCT pullback (MGH system, light source 1,310 nm, 105 fps, pullback speed 20 mm/s) was acquired during brief (3 s) injection of X-ray contrast (flow 3 ml/s) through the guiding catheter. A second pullback was repeated under the same conditions after re-introduction of the FD OCT catheter into the coronary artery. IVUS and OCT imaging was performed in random order. FD-OCT and IVUS pullback data were analyzed using a recently developed software employing semi automated lumen contour and stent strut detection algorithms. Corresponding ROI were matched based on anatomical landmarks such as side branches and/or stent edges. Inter-study variability is presented as the absolute difference between the two pullbacks. FD-OCT showed remarkably good reproducibility. Inter-study variability in native vessels (cohort A) was very low for mean and minimal luminal area (0.10 ± 0.38, 0.19 ± 0.57 mm2, respectively). Likewise inter-study variability was very low in stented coronary segments (cohort B) for mean lumen, mean stent, minimal luminal and minimal stent area (0.06 ± 0.08, 0.07 ± 0.10, 0.04 ± 0.09, 0.04 ± 0.10 mm2, respectively). Comparison to IVUS morphometry revealed no significant differences. The differences between both imaging methods, OCT and IVUS, were very low for mean lumen, mean stent, minimal luminal and minimal stent area (0.10 ± 0.45, 0.10 ± 0.36, 0.26 ± 0.54, 0.05 ± 0.47 mm2, respectively). FD-OCT shows excellent reproducibility and very low inter-study variability in both, native and stented coronary segments. No significant differences in quantitative lumen morphometry were observed between FD-OCT and IVUS. Evaluating these results suggest that FD-OCT is a reliable imaging tool to apply in longitudinal coronary artery disease studies.
Collapse
Affiliation(s)
- Z Jamil
- Thoraxcenter, Bd 585, Erasmus MC, Dr. Molewaterplein 40, 3015-GD, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Brugaletta S, Gomez-Lara J, Garcia-Garcia HM, Heo JH, Farooq V, van Geuns RJ, Chevalier B, Windecker S, McClean D, Thuesen L, Whitbourn R, Meredith I, Dorange C, Veldhof S, Rapoza R, Ormiston JA, Serruys PW. Analysis of 1 year virtual histology changes in coronary plaque located behind the struts of the everolimus eluting bioresorbable vascular scaffold. Int J Cardiovasc Imaging 2011; 28:1307-14. [PMID: 22108907 PMCID: PMC3463791 DOI: 10.1007/s10554-011-9981-4] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2011] [Accepted: 11/14/2011] [Indexed: 11/29/2022]
Abstract
Serial intravascular ultrasound virtual histology (IVUS-VH) after implantation of metallic stents has been unable to show any changes in the composition of the scaffolded plaque overtime. The everolimus-eluting ABSORB scaffold potentially allows for the formation of new fibrotic tissue on the scaffolded coronary plaque during bioresorption. We examined the 12 month IVUS-VH changes in composition of the plaque behind the struts (PBS) following the implantation of the ABSORB scaffold. Using IVUS-VH and dedicated software, the composition of the PBS was analyzed in all patients from the ABSORB Cohort B2 trial, who were imaged with a commercially available IVUS-VH console (s5i system, Volcano Corporation, Rancho Cordova, CA, USA), immediately post-ABSORB implantation and at 12 month follow-up. Paired IVUS-VH data, recorded with s5i system, were available in 17 patients (18 lesions). The analysis demonstrated an increase in mean PBS area (2.39 ± 1.85 mm2 vs. 2.76 ± 1.79 mm2, P = 0.078) and a reduction in the mean lumen area (6.37 ± 0.90 mm2 vs. 5.98 ± 0.97 mm2, P = 0.006). Conversely, a significant decrease of 16 and 30% in necrotic core (NC) and dense calcium (DC) content, respectively, were evident (median % NC from 43.24 to 36.06%, P = 0.016; median % DC from 20.28 to 11.36%, P = 0.002). Serial IVUS-VH analyses of plaque located behind the ABSORB struts at 12-month demonstrated an increase in plaque area with a decrease in its NC and DC content. Larger studies are required to investigate the clinical impact of these findings.
Collapse
Affiliation(s)
- Salvatore Brugaletta
- Department of Interventional Cardiology, Thoraxcenter, Erasmus MC, 's Gravendijkwal 230, 3015, Rotterdam, CE, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Brugaletta S, Garcia-Garcia HM, Serruys PW, de Boer S, Ligthart J, Gomez-Lara J, Witberg K, Diletti R, Wykrzykowska J, van Geuns RJ, Schultz C, Regar E, Duckers HJ, van Mieghem N, de Jaegere P, Madden SP, Muller JE, van der Steen AF, van der Giessen WJ, Boersma E. NIRS and IVUS for Characterization of Atherosclerosis in Patients Undergoing Coronary Angiography. JACC Cardiovasc Imaging 2011; 4:647-55. [DOI: 10.1016/j.jcmg.2011.03.013] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2010] [Revised: 03/07/2011] [Accepted: 03/14/2011] [Indexed: 10/18/2022]
|
8
|
Temporal changes of coronary artery plaque located behind the struts of the everolimus eluting bioresorbable vascular scaffold. Int J Cardiovasc Imaging 2010; 27:859-66. [PMID: 20941544 DOI: 10.1007/s10554-010-9724-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2010] [Accepted: 09/29/2010] [Indexed: 02/07/2023]
Abstract
Implantation of a coronary stent results in a mechanical enlargement of the coronary lumen with stretching of the surrounding atherosclerotic plaque. Using intravascular ultrasound virtual-histology (IVUS-VH) we examined the temporal changes in composition of the plaque behind the struts (PBS) following the implantation of the everolimus eluting bioresorbable vascular scaffold (BVS). Using IVUS-VH and dedicated software, the composition of plaque was analyzed in all patients from the ABSORB B trial who were imaged with a commercially available IVUS-VH console (s5i system, Volcano Corporation, Rancho Cordova, CA, USA) post-treatment and at 6-month follow-up. This dedicated software enabled analysis of the PBS after subtraction of the VH signal generated by the struts. The presence of necrotic core (NC) in contact with the lumen was also evaluated at baseline and follow-up. IVUS-VH data, recorded with s5i system, were available at baseline and 6-month follow-up in 15 patients and demonstrated an increase in both the area of PBS (2.45 ± 1.93 mm(2) vs. 3.19 ± 2.48 mm(2), P = 0.005) and the external elastic membrane area (13.76 ± 4.07 mm(2) vs. 14.76 ± 4.56 mm(2), P = 0.006). Compared to baseline there was a significant progression in the NC (0.85 ± 0.70 mm(2) vs. 1.21 ± 0.92 mm(2), P = 0.010) and fibrous tissue area (0.88 ± 0.79 mm(2) vs. 1.15 ± 1.05 mm(2), P = 0.027) of the PBS. The NC in contact with the lumen in the treated segment did not increase with follow-up (7.33 vs. 6.36%, P = 0.2). Serial IVUS-VH analysis of BVS-treated lesions at 6-month demonstrated a progression in the NC and fibrous tissue content of PBS.
Collapse
|
9
|
Yamazaki T, Suzuki JI, Shimamoto R, Tsuji T, Ohmoto-Sekine Y, Morita T, Yamashita H, Honye J, Nagai R, Komatsu S, Akahane M, Ohtomo K. Diagnostic efficacy for coronary in-stent patency with parameters defined on Hounsfield CT value-spatial profile curves. Radiography (Lond) 2008. [DOI: 10.1016/j.radi.2006.12.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
10
|
Rodriguez-Granillo GA, de Winter S, Bruining N, Ligthart JMR, García-García HM, Valgimigli M, de Feyter PJ. Effect of perindopril on coronary remodelling: insights from a multicentre, randomized study. Eur Heart J 2007; 28:2326-31. [PMID: 17766284 DOI: 10.1093/eurheartj/ehm255] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS This study sought to evaluate the effect of perindopril in coronary remodelling. METHODS AND RESULTS In this sub-study of a double-blind, multicentre trial, patients without clinical evidence of heart failure were randomized to perindopril 8 mg/day or placebo for at least 3 years and IVUS investigation was performed at both time-points. Positive and negative remodelling were defined as a relative increase (positive remodelling) or decrease (negative remodelling) of the mean vessel cross-sectional area (CSA)>2 SD of the mean intra-observer difference. A total of 118 matched evaluable IVUS (711 matched 5 mm segments) were available at follow-up. After a median follow-up of 3.0 (inter-quartile range 1.9, 4.1) years, there was no significant difference in the change of plaque CSA between perindopril (360 segments) and placebo (351 segments) groups, P=0.27. Conversely, the change in vessel CSA was significantly different between groups (perindopril -0.18+/-2.4 mm2 vs. placebo 0.19+/-2.4, P = 0.04). Negative remodelling occurred more frequently in the perindopril than in the placebo group (34 vs. 25%, P=0.01). In addition, the placebo group showed a larger, although not significant, mean remodelling index (RI) than the perindopril group (1.03+/-0.2 vs. 1.00+/-0.2, P=0.06). The temporal change in vessel dimensions assessed by the RI was significantly correlated with the change in plaque dimensions (r=0.48, P<0.0001). CONCLUSION In this sub-analysis of a multicentre, controlled study, long-term administration of perindopril was associated with a constrictive remodelling pattern without affecting the lumen.
Collapse
|
11
|
Rodriguez-Granillo GA, McFadden EP, Aoki J, van Mieghem CAG, Regar E, Bruining N, Serruys PW. In vivo variability in quantitative coronary ultrasound and tissue characterization measurements with mechanical and phased-array catheters. Int J Cardiovasc Imaging 2005; 22:47-53. [PMID: 16362171 DOI: 10.1007/s10554-005-6423-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/03/2005] [Accepted: 04/26/2005] [Indexed: 01/09/2023]
Abstract
BACKGROUND Both mechanical and phased-array catheters are used in clinical trials to assess quantitative parameters. Only limited evaluation of the in vivo agreement of volumetrical measurements between such systems has been performed, despite the fact that such information is essential for the conduction of atherosclerosis regression trials. METHODS AND RESULTS We prospectively evaluated the agreement in morphometric measurements and intravascular ultrasound (IVUS)-based plaque characterization between a 40 MHz rotating transducer (3.2 F Atlantis, Boston Scientific Corp.) and a 20 MHz phased-array catheter (2.9 F Eagle Eye, Volcano Therapeutics, Rancho Cordova, California) in 16 patients. Lumen (7.3+/-2.0 mm(2) vs. 6.7+/-1.8 mm(2), p=0.001) and vessel (11.8+/-3.3 mm(2) vs. 11.0+/-2.9 mm(2), p=0.02) cross-sectional areas (CSA) were significantly greater with the 20 MHz system. Plaque CSA measurements showed no significant difference between systems (4.4+/-2.3 mm(2) vs. 4.4+/-2.1). The relative differences were less than 10% for the three variables. On IVUS-based tissue characterization (13 patients), calculated percentage hypoechogenic volume was significantly higher for the 20 MHz system (96.7+/-2.38 vs. 88.4+/-5.53, p<0.0001). CONCLUSIONS Quantitative IVUS analyses display significant catheter type-dependent variability. It is unclear whether the variability reflects overestimation of measurements with the phased-array or underestimation with the mechanical system. Although plaque burden measurements did not differ significantly between systems, it appears prudent to recommend the use of a single system for progression/regression studies.
Collapse
|
12
|
Li Y, Honye J, Saito S, Takayama T, Yokoyama SI, Saruya T, Kotani M, Harasawa K, Ando H, Endo M, Kanmatsuse K. Variability in quantitative measurement of the same segment with two different intravascular ultrasound systems: in vivo and in vitro studies. Catheter Cardiovasc Interv 2004; 62:175-80. [PMID: 15170706 DOI: 10.1002/ccd.20052] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
We evaluated two different intravascular ultrasound (IVUS) systems, Atlantis and Intrafocus, to verify their accuracy and reproducibility. In an in vivo study on 20 consecutive patients with coronary artery diseases, the minimum lumen diameter (MLD), vessel diameter, lumen area (LA), vessel area, plaque area, and area stenosis rate (% AS) were respectively measured. In an in vitro study, MLD and LA were measured in four metal tubes with different diameters. All of the measured values except for % AS by Atlantis were significantly larger than the values obtained with Intrafocus. Nonuniform rotational distortion (NURD) was estimated as 34% in Atlantis and 1% in Intrafocus. The measurements by Atlantis were larger than the true values while the measurements by Intrafocus were less than the true values in all four metal tubes. These findings suggest that we should clearly avoid the use of different IVUS systems in the same study.
Collapse
Affiliation(s)
- Yuxin Li
- Division of Cardiology, Second Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Bocksch W, Wellnhofer E, Klimek W, Schartl M, Dreysse S, Musci M, Hummel M, Hetzer R. Intravascular ultrasound assessment of longitudinal plaque distribution patterns in patients with angiographically silent coronary artery disease after heart transplantation. Coron Artery Dis 2002; 13:349-56. [PMID: 12488643 DOI: 10.1097/00019501-200211000-00001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
AIMS The purpose of this three-dimensional intracoronary ultrasound (ICUS) study was to assess longitudinal plaque distribution patterns in patients with angiographically silent coronary artery disease (CAD) after heart transplantation (HTX). METHODS AND RESULTS Out of 334 patients without diameter stenosis >/=25% determined by coronary angiography, 321 underwent successful three-dimensional ICUS (30 MHz) of the left main coronary artery (LMCA) and all segments of the left anterior descending coronary artery (LAD). Early plaque formation was found in 296 patients (92.2%). Single (focal CAD, n = 65) or multiple (polyfocal CAD, n = 77), discrete coronary lesions were found in 142 patients and continuous plaque formation of at least one entire coronary segment (diffuse CAD) in 154 patients. Using multivariate regression analysis, male sex (P = 0.01), increasing post-transplantation time (P = 0.003) and increasing donor age (P = 0.001) were independent clinical predictors for diffuse CAD. Both focal and diffuse CAD most frequently affected the proximal LAD (88% compared with 89.6%, NS). The mean intimal index of each LAD segment was significantly higher in patients with diffuse CAD (P < 0.001) and showed a proximal-to-distal decline in patients with focal/polyfocal (LMCA, 10.1 +/- 14.3, LAD-6, 30.1 +/- 17.4%, LAD-7, 16.3 +/- 14.1%, LAD-8, 4.6 +/- 11.1%; P < 0.001) and diffuse (LMCA, 27.0 +/- 16.0, LAD-6, 47.8 +/- 16.1%, LAD-7, 41.9 +/- 14.5%, LAD-8, 24.9 +/- 23.3%; P < 0.01) CAD. CONCLUSION Evaluation of longitudinal plaque distribution after HTX by three-dimensional ICUS revealed a time-dependent increase in the incidence of diffuse CAD and a proximal-to-distal decline in frequency and magnitude of early plaque formation.
Collapse
Affiliation(s)
- Wolfgang Bocksch
- Department of Internal Medicine-Cardiology, Humboldt University Berlin, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Stähr P, Voigtländer T, Rupprecht HJ, Aschenbrücker P, Mamtimin H, Brennecke R, Otto M, Fitzgerald PJ, Meyer J. Impact of vessel curvature on the accuracy of three-dimensional intravascular ultrasound: validation by phantoms and coronary segments. J Am Soc Echocardiogr 2002; 15:823-30. [PMID: 12174352 DOI: 10.1067/mje.2002.120700] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND Three-dimensional intravascular ultrasound (IVUS) is used for volumetric assessment of arteriosclerotic plaque burden and restenotic tissue at follow-up after coronary interventions. However, the accuracy of these measurements, especially in tortuous vessels, is unclear. METHODS A commercially available electrocardiogram (ECG)-gated 3-dimensional-IVUS system was tested in volume-validated straight and curved hydrocolloid phantoms and in volume-validated coronary specimens. Catheter withdrawal (30 MHz, 3.2F) was triggered using standardized ECG source with 0.2-mm step intervals per cardiac cycle simulation. RESULTS On the basis of automated phantom volume measurements, IVUS overestimated true phantom volume (relative error = [measured V - true V]/true V x 100) by a median of 0.9%, 0.25%, and 1.96% for straight, mildly curved, and severely curved segments, respectively. The true volume of the coronary specimens was overestimated by a median of 5.79%. CONCLUSION A median percentage deviation of 3-dimensional-IVUS-measured volumes from the true volumes of less than 10% in phantoms and coronary artery segments can be achieved.
Collapse
Affiliation(s)
- Peter Stähr
- Stanford University Medical School, CA 94305, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Beckman JA, Ganz J, Creager MA, Ganz P, Kinlay S. Relationship of clinical presentation and calcification of culprit coronary artery stenoses. Arterioscler Thromb Vasc Biol 2001; 21:1618-22. [PMID: 11597935 DOI: 10.1161/hq0901.095554] [Citation(s) in RCA: 147] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Coronary artery calcification is increased in the presence of atherosclerosis. However, there is great variability in the calcification of individual coronary stenoses, and the clinical significance of this finding remains unknown. We tested the hypothesis that culprit lesions associated with myocardial infarction or unstable angina are less calcified than are stenoses associated with stable angina. The study consisted of 78 patients who underwent intravascular ultrasound imaging of culprit stenoses after the placement of a stent. Seventeen patients presented with stable angina; 43, with unstable angina; and 18, with myocardial infarction. The extent of coronary calcification was measured by the angle of its arc and was quantified with a computer-based protractor. The arc of calcium was measured in the stented area at the point of maximal calcification and also as an average of the calcification found at proximal, middle, and distal stent segments. The maximal arc of calcium decreased progressively from patients with stable angina (91+/-10 degrees ) to those with unstable angina (59+/-8 degrees ) and to those with myocardial infarction (49+/-11 degrees, P=0.014). Similarly, the average arc of calcium was greatest (32+/-7 degrees ) in patients with stable angina, less (15+/-4 degrees ) in patients with unstable angina, and least (10+/-5 degrees ) in patients with acute myocardial infarction (P=0.014). These associations remained significant after adjustment for other factors that potentially affect arterial calcification. Acute coronary syndromes are associated with a relative lack of calcium in the culprit stenoses compared with stenoses of patients with stable angina. These findings have implications for the understanding of the biology of acute coronary syndromes as well as for the identification of coronary stenoses by methods that rely solely on the presence of calcium.
Collapse
Affiliation(s)
- J A Beckman
- Cardiovascular Division, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| | | | | | | | | |
Collapse
|
16
|
Gaster AL, Korsholm L, Thayssen P, Pedersen KE, Haghfelt TH. Reproducibility of intravascular ultrasound and intracoronary Doppler measurements. Catheter Cardiovasc Interv 2001; 53:449-58. [PMID: 11514993 DOI: 10.1002/ccd.1202] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The aim of this study was to evaluate the reproducibility of intravascular ultrasound (IVUS) and intracoronary (IC) Doppler flow velocity measurements. The use of IVUS and IC Doppler has been suggested as a means for percutaneous coronary intervention (PCI) guidance in a series of studies. This would require an acceptable level of accuracy and reproducibility of these two methods for lesion evaluation. In this study, the main focus was on the issue of reproducibility. One hundred and eight patients referred for PCI entered into the study. Inter- and intraobserver variability was measured. Catheter difference was assessed. On-line and off-line measurements were compared. MUSIC criteria were assessed off-line, twice. Calculated and measured diameters were compared. After having obtained initial IC Doppler measurements, the Doppler wire was immediately withdrawn and repositioned for reacquisition of Doppler measurements. IVUS measurements are reproducible and reliable off-line and, to a slightly lesser degree, on-line. Area measurements should be performed more than once and the mean used for vessel description. Lumen diameters should be calculated from the mean of the area measurements. A measuring technique consensus should be reached and adhered to. CFR measurements can be used to determine reduced vs. normal flow reserve. In this study, it was found that proximal to distal velocity ratio and diastolic to systolic velocity ratio variability made these parameters unsuitable for PCI guidance.
Collapse
Affiliation(s)
- A L Gaster
- Department of Cardiology, Odense University Hospital, Odense, Denmark.
| | | | | | | | | |
Collapse
|
17
|
Takayama T, Hodgson JM. Prediction of the physiologic severity of coronary lesions using 3D IVUS: validation by direct coronary pressure measurements. Catheter Cardiovasc Interv 2001; 53:48-55. [PMID: 11329218 DOI: 10.1002/ccd.1129] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This study was performed to determine whether three-dimensional intravascular ultrasound (3D IVUS) could predict the physiologic significance of coronary lesions. Seventeen lesions were evaluated by means of 3D IVUS, pressure measurements, and quantitative coronary angiography. Physiologic parameters were calculated from the 3D IVUS measures using established equations and compared to values measured by pressure guidewire. IVUS minimum lumen area (MLA) correlated with fractional flow reserve (FFR; R2 = 0.55, P = 0.003) and pressure gradient (R2 = 0.52, P = 0.003). Lesion length (L) had a positive correlation with pressure gradient (R2 = 0.45, P = 0.007). By multivariate analysis, the only significant independent determinant of FFR was MLA/L measured by IVUS. The IVUS-predicted pressure gradient and FFR were well correlated with values measured directly (R2) = 0.88, P < 0.001; R2 = 0.90, P < 0.001, respectively). The physiologic severity of coronary lesions is primarily influenced by lumen area and lesion length and can be established by 3D IVUS.
Collapse
Affiliation(s)
- T Takayama
- Heart and Vascular Center, MetroHealth Medical Center, Case Western Reserve University, Cleveland, Ohio, USA
| | | |
Collapse
|
18
|
Hibi K, Takagi A, Zhang X, Teo TJ, Bonneau HN, Yock PG, Fitzgerald PJ. Feasibility of a novel blood noise reduction algorithm to enhance reproducibility of ultra-high-frequency intravascular ultrasound images. Circulation 2000; 102:1657-63. [PMID: 11015344 DOI: 10.1161/01.cir.102.14.1657] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Ultra-high-frequency (40- to 50-MHz) intravascular ultrasound (IVUS) improves image quality compared with conventional 20- to 30-MHz IVUS. However, as the frequency of IVUS increases, high-intensity backscatter from blood components may cause visual difficulties in discrimination between the lumen and arterial wall structure. The purpose of this study was to evaluate the effect of a novel blood noise reduction algorithm (BNR) on quantitative coronary ultrasound measurements. METHODS AND RESULTS IVUS studies using a 40-MHz transducer were performed in 35 patients with coronary artery disease. A total of 620 gray-scale images (310 pairs) were processed with and without the BNR, and lumen cross-sectional area (CSA) was determined by 2 independent observers. With the BNR, the intraobserver and interobserver correlation coefficients for lumen CSA were significantly improved (0.85 to 0.99 and 0.80 to 0.98, respectively). In the 270 images (135 pairs) in which vessel wall measurements were possible, the BNR significantly improved the intraobserver and interobserver correlation coefficients for plaque plus media CSA (0.83 to 0.99 and 0.76 to 0.97, respectively), whereas no influence was observed for external elastic membrane CSA (1.00 to 1.00 and 0.99 to 0.99, respectively). CONCLUSIONS This study demonstrates the feasibility of this novel algorithm to reduce blood noise, thereby enabling accurate lumen border delineation and providing reproducible measurements of both the lumen and plaque plus media CSAs. Incorporating a digital BNR may serve as an important adjunct to ultra-high-frequency IVUS imaging for improving accurate quantitative evaluation of vessel dimensions.
Collapse
Affiliation(s)
- K Hibi
- Division of Cardiovascular Medicine, Stanford University Medical Center, Stanford, CA 94305, USA
| | | | | | | | | | | | | |
Collapse
|
19
|
Bocksch W, Wellnhofer E, Schartl M, Dreysse S, Klimek W, Franke R, Musci M, Hetzer R, Fleck E. Reproducibility of serial intravascular ultrasound measurements in patients with angiographically silent coronary artery disease after heart transplantation. Coron Artery Dis 2000; 11:555-62. [PMID: 11023244 DOI: 10.1097/00019501-200010000-00007] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Intracoronary ultrasound (ICUS) imaging is the most sensitive method for the early detection and serial evaluation of vasculopathy of transplants. Both lack of agreement between observers and lack of agreement between serial, independent pullback procedures (repeatability), which can result in a variable intraluminal catheter position may limit the reproducibility of ICUS measurements. OBJECTIVE To evaluate the reproducibility of serial measurements of standard linear and area cross-sectional coronary dimensions in patients with non-obstructive transplant vasculopathy. METHODS We performed ICUS imaging of patients without angiographic evidence of obstructive epicardial coronary artery disease after heart transplantation. A 30 MHz phased-array transducer was used. Two independent pullbacks of the left anterior descending coronary artery were performed and recorded on CD-ROM for off-line quantitative analysis of the most severely diseased site. Agreement of observers and repeatability of serial measurements were calculated by the use of linear regression analysis and Bland-Altman plots. RESULTS Regarding agreement of observers, correlation coefficients for intra-observer agreement ranged from r = 0.98 to r = 0.99; those for interobserver agreement ranged from r = 0.87 to r = 0.98. Serial measurements of the identical coronary artery cross-section within independent catheter pullback procedures were possible for 104 of 112 target lesions (92.90/%). Correlation coefficients ranged from r = 0.91 to r = 0.97 (for lumen diameter r = 0.91, for lumen area r = 0.93, for vessel diameter r = 0.91, for vessel area r = 0.97, for thickness of plaque r = 0.96 and for area of plaque 0.94). The mean difference of measurements was around zero for all parameters with SD from 0.13 to 0.4 mm for linear parameters and from 1.53 to 1.82 mm2 for area parameters. CONCLUSION Serial intravascular ultrasound measurements are highly reproducible without any evidence of systematic error and a SD of differences of measurements beyond the maximal spatial resolution of currently available intravascular ultrasound catheters.
Collapse
Affiliation(s)
- W Bocksch
- Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Humboldt Universität zu Berlin.
| | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Takagi A, Hibi K, Zhang X, Teo TJ, Bonneau HN, Yock PG, Fitzgerald PJ. Automated contour detection for high-frequency intravascular ultrasound imaging: a technique with blood noise reduction for edge enhancement. ULTRASOUND IN MEDICINE & BIOLOGY 2000; 26:1033-1041. [PMID: 10996703 DOI: 10.1016/s0301-5629(00)00251-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Automated edge detection may standardize measurements among observers, providing for rapid assessment of intravascular ultrasound (IVUS) images. However, with high frequency images, enhanced blood signals make it difficult to define and trace the lumen borders. Accordingly, we evaluated a fully automated contour analysis facilitated with a blood noise reduction algorithm (BNR) for 40-MHz IVUS images in human coronary arteries of 27 patients. This algorithm is based on the principle that blood echo speckles have higher temporal and spatial variations than the arterial wall. A total of 193 paired lumen areas and 78 external elastic membrane (EEM) areas were measured and compared. Automated measurements showed good agreement with manual tracings for lumen and EEM area, with high correlation coefficients (0.945 and 0.950, respectively) and small variability (0.4 +/- 14.4% and 0.6 +/- 9.7%, respectively). This preliminary finding suggests that automated contour detection facilitated with BNR appeared to be a feasible and reliable technique for area measurements in 40-MHz IVUS imaging.
Collapse
Affiliation(s)
- A Takagi
- Division of Cardiovascular Medicine, Stanford University Medical Center, Stanford, CA 94305, USA
| | | | | | | | | | | | | |
Collapse
|
21
|
Regar E, Werner F, Siebert U, Rieber J, Theisen K, Mudra H, Klauss V. Reproducibility of neointima quantification with motorized intravascular ultrasound pullback in stented coronary arteries. Am Heart J 2000; 139:632-7. [PMID: 10740144 DOI: 10.1016/s0002-8703(00)90040-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND Intravascular ultrasound (IVUS) imaging has shown excellent reproducibility immediately after coronary stent implantation. However, the variability of measurements in lesions late after stent implantation, when neointima formation is present, has not been studied. Neointimal tissue is generally low echogenic and thus difficult to quantify. We therefore sought to analyze the reproducibility of morphometric measurements late after stent implantation. METHODS AND RESULTS Fifty consecutive patients were investigated 6 months after Palmaz-Schatz stent implantation (motorized catheter pullback 0.5 mm/s). Two experienced investigators independently identified the stent area, lumen area, and neointimal area at different sites within the stent. Planimetric measurements were performed with commercially available software. Correlation coefficient and mean difference for corresponding measurements were calculated for the intraobserver and interobserver comparisons. Variability for the intraobserver and interobserver comparisons was similar. Observer agreement regarding the presence of neointimal hyperplasia was as high as 71% (interobserver comparison 62%). The mean difference for neointima area was 0.06 +/- 1.5 mm(2) (-0.6 +/- 1.5 mm(2)); mean differences for lumen area were 0.02 +/- 0.19 mm(2) (0.03 +/- 0.17 mm(2)) and for stent area 0.01 +/- 0.09 mm(2) (-0.02 +/- 0.12 mm(2)) (values for interobserver comparison are given in parentheses). Correlation between measurements was high for all structures: correlation coefficients were 0.66 (0.69) for neointima, 0.94 (0.95) for lumen, and 0.95 (0. 91) for stent area. CONCLUSIONS Morphometric measurements of IVUS investigations with motorized IVUS pullback late after stent placement show good reproducibility. Intraobserver variability and interobserver variability are low. Differences for corresponding measurements were more pronounced for neointima area. Motorized catheter pullback guarantees high reliability of IVUS measurements and should be used routinely for clinical IVUS studies.
Collapse
Affiliation(s)
- E Regar
- Medizinische Klinik, Klinikum Innenstadt, and Institut für Medizinische Informatik, Biometrie und Epidemiologie, University of Munich, Germany
| | | | | | | | | | | | | |
Collapse
|
22
|
Regar E, Werner F, Klauss V, Siebert U, Henneke KH, Rieber J, König A, Theisen K, Mudra H. IVUS analysis of the acute and long-term stent result using motorized pullback: intraobserver and interobserver variability. Catheter Cardiovasc Interv 1999; 48:245-50. [PMID: 10525220 DOI: 10.1002/(sici)1522-726x(199911)48:3<245::aid-ccd1>3.0.co;2-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Intravascular ultrasound imaging has become an established method for analysis of intra-coronary stents. We analyzed the reproducibility of morphometric measurements immediately and late after stent implantation and the variability in the selection of predefined sites during motorized catheter pullback. Fifty consecutive patients were investigated immediately and 6 months after Palmaz-Schatz stent implantation (motorized catheter pullback 0.5 mm/sec; 2.9 Fr; 30-MHz transducer). Two experienced investigators independently identified the proximal and distal reference, stent inlet, stent outlet, and the minimal in-stent area in each imaging run. The longitudinal distance between corresponding measurement sites was calculated. Lumen, stent, and vessel area were assessed by planimetry, mean difference was calculated. Long-term reproducibility was analyzed by comparison of measurements made at predefined sites within the stent, immediately and late after implantation. Observer agreement in identification of predefined measurement sites was high. Longitudinal distance between corresponding measurement sites was low and pronounced for the minimal in-stent lumen area. Variabilities for the intra- and interobserver comparison were similar. Values for interobserver comparison were given in brackets. Acute after stent implantation, the variability for the reference proximal was 4.9% (0.4%), distal -1.0% (-4.2%), minimal in-stent lumen -0.5% (1.3%). At follow-up, variability for the reference proximal was -11.0% (-2.2%), distal -1.0% (-2.3%), minimal in-stent lumen 1.9% (6.1%). Long-term reproducibility for the proximal stent inlet was 2.7% (observer 1) and -0.4% (observer 2), for the distal stent outlet 1.3% (observer 1), -3.0% (observer 2), respectively. IVUS investigations with motorized IVUS pullback in stented coronary segments show a low intra- and interobserver variability, both immediately and late after stent implantation. Absolute and relative area differences are low. Long-term reproducibility of measurements within predefined stent sites was high. Motorized catheter pullback guarantees high reliability of IVUS measurements and should be routinely used for clinical IVUS studies.
Collapse
Affiliation(s)
- E Regar
- Medizinische Klinik, Klinikum Innenstadt, University of Munich, Munich, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Delacrétaz E, Fleisch M, Kaufmann UP, Lüscher TF, Brunner HR, Meier B, Hayoz D. Coronary and peripheral artery remodeling in patients undergoing PTCA: An intracoronary and transcutaneous ultrasound study. Catheter Cardiovasc Interv 1999; 48:12-7. [PMID: 10467064 DOI: 10.1002/(sici)1522-726x(199909)48:1<12::aid-ccd3>3.0.co;2-#] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The aim of this study was to assess the relationship between the plaque burden of nonstenotic coronary artery segments and the wall thickness of peripheral arteries using intracoronary and transcutaneous ultrasound imaging, respectively. Intracoronary ultrasound (CVIS, 3.5 Fr) was performed in 27 patients undergoing percutaneous transluminal coronary angioplasty. Carotid arteries were imaged by B-mode ultrasound with semiautomatic edge detection and radial arteries by high resolution A-mode echotracking (NIUS 2). Quantitative measurements included coronary artery intima-media cross-sectional area (IM(CSA)) and cross-sectional narrowing (CSN), as well as intima-media thickness (IMT) and lumen radius (r) of the common carotid and the radial arteries. Intima-media thickness was increased in coronary, carotid, and radial arteries. Coronary arteries had an IM(CSA) of 7.7 +/- 2.5 mm(2) and a CSN of 24% +/- 8%. Despite this moderate plaque burden, lumen area was preserved (12.3 +/- 4.2 mm(2)) because of compensatory enlargement of coronary arteries. Right and left carotid and right radial arteries had an IMT of 575 +/- 78 microm, 570 +/- 129 microm, and 328 +/- 61 microm, respectively. There was no correlation between coronary IM(CSA) and carotid IMT (r = 0.07) or radial IMT (r = 0.02), and there was no correlation between coronary CSN and carotid IMT/r (r = 0.12), or radial IMT/r (r = 0.25). In conclusion, in these patients with symptomatic ischemic disease no relationship between IMT of the coronary arteries and IMT of carotid or radial arteries was found. Although increasingly popular, IMT of peripheral arteries may be of limited value as surrogate marker for the severity of coronary artery disease. Cathet. Cardiovasc. Intervent. 48:12-17, 1999.
Collapse
Affiliation(s)
- E Delacrétaz
- Department of Cardiology, University Hospital, Bern, Switzerland.
| | | | | | | | | | | | | |
Collapse
|
24
|
Smits PC, Pasterkamp G, Eefting FD, Stella PR, de Jaegere PP, Borst C. Clinical implications of online and off-line interobserver variability in intracoronary ultrasound-guided interventions. ULTRASOUND IN MEDICINE & BIOLOGY 1999; 25:509-514. [PMID: 10386725 DOI: 10.1016/s0301-5629(99)00009-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
UNLABELLED Intracoronary ultrasound (ICUS)-guided interventions imply online decision making. We investigated the on- and off-line interobserver variability in ICUS measurements and evaluated the clinical implication of the interobserver variability for ICUS-guided interventions in 40 lesions (38 patients). On the same recorded ICUS images, an online and an off-line observer independently selected and analyzed the proximal and distal reference images, the most severe stenosis image before intervention and the minimal lumen area (MLA) image after intervention. In addition, the off-line observer analyzed the online selected images. The interobserver variability (percentage difference between the two observers) of ICUS measurements was determined on images independently selected by both observers (Analysis A) and on images selected by the online observer (Analysis B). The balloon size was determined from ICUS measurements according to the CLOUT trial. After intervention, the CLOUT and MUSIC criteria for MLA by ICUS had to be fulfilled for PTCA and stent procedures, respectively. In Analysis A, the on- and off-line interobserver variability in diameter and area measurements was maximally 9% and 18%, respectively. In Analysis B, the on- and off-line interobserver variability was maximally 6% and 11%, respectively. The off-line observer would have chosen a balloon size differing by more than 0.25 mm in 25 % (10 of 40) and 12.5% (5 of 40) of the procedures in Analysis A and B, respectively. After PTCA or stenting, the off-line observer would have taken different procedural decisions in 19% or 15% and in 13% or 7% of the procedures in Analysis A and B, respectively. IN CONCLUSION when the same location was selected, the on- and off-line interobserver variability was low. When different locations were selected, however, the interobserver variability resulted in different balloon sizing in 25 % of the cases. Interobserver variability may be a confounding factor in the analysis of ICUS-guided interventions.
Collapse
Affiliation(s)
- P C Smits
- Department of Cardiology, Heart Lung Institute, University Hospital, Utrecht, The Netherlands.
| | | | | | | | | | | |
Collapse
|
25
|
Allen-Auerbach M, Schöder H, Johnson J, Kofoed K, Einhorn K, Phelps ME, Kobashigawa J, Czernin J. Relationship between coronary function by positron emission tomography and temporal changes in morphology by intravascular ultrasound (IVUS) in transplant recipients. J Heart Lung Transplant 1999; 18:211-9. [PMID: 10328146 DOI: 10.1016/s1053-2498(98)00037-0] [Citation(s) in RCA: 46] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
BACKGROUND Transplant coronary vasculopathy is one of the major causes of graft failure and death in cardiac transplant recipients. A non-invasive test of coronary function to predict the course of this disease would be desirable. METHODS To determine whether the degree of abnormalities in endothelial dependent coronary vasomotion (cold pressor testing) or endothelial independent vasodilatory capacity (intravenous dipyridamole) as determined by positron emission tomography (PET) one to two years after heart transplantation is correlated with the course of transplant vasculopathy. Nineteen patients had baseline PET and intravascular ultrasound studies (IVUS) at 18 +/- 6 months after cardiac transplantation and a follow up IVUS study 15 +/- 5 months later. RESULTS Myocardial blood flow was higher in patients than in healthy controls (p < 0.002) but increased during cold pressor testing only in controls (p < 0.005). Myocardial blood flow normalized to the rate pressure product declined in patients (p < 0.001). Dipyridamole-induced hyperemic blood flow and the flow reserve normalized to the resting rate pressure product were lower in patients than in controls (p < 0.001 and p < 0.01). The normalized flow reserve was correlated with changes in total vessel area (r = 0.55; p = 0.02) and lumen diameter (r = 0.52; p < 0.05). CONCLUSION These findings suggest that the degree of abnormalities in endothelial independent myocardial flow as detected by PET one to two years after transplantation is associated with morphological indices of disease progression by IVUS.
Collapse
Affiliation(s)
- M Allen-Auerbach
- Department of Molecular and Medical Pharmacology, UCLA School of Medicine, Los Angeles, California 90095-6948, USA
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Blessing E, Hausmann D, Sturm M, Wolpers HG, Amende I, Mügge A. Intravascular ultrasound and stent implantation: intraobserver and interobserver variability. Am Heart J 1999; 137:368-71. [PMID: 9924173 DOI: 10.1053/hj.1999.v137.93032] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND Intravascular ultrasound (IVUS) imaging can be used to optimize implantation of intracoronary stents; the variability of the measurements, however, remains unclear. Our aim in this study was to determine the intraobserver and interobserver variability of IVUS measurements after stent implantation. METHODS Ninety-four patients underwent implantation of 100 Palmaz-Schatz stents in 98 lesions (79 de novo and 19 restenotic). IVUS measurements (3.5F, 30 MHz) of proximal and distal reference sections and of the smallest stent lumen were performed by 2 investigators. RESULTS Intraobserver and interobserver correlations, respectively, were r = 0.96 and 0.93 for the proximal reference, r = 0.94 and 0.92 for the distal reference, and r = 0.97 and 0.97 for minimal stent lumen. Stent expansion (minimal lumen in the stent/mean reference area) showed a variability of r = 0.80 and 0.70. Taking a cutoff point of 90% for adequacy of stent expansion, observers agreed in only 77% whether the stent was adequately or inadequately expanded. CONCLUSIONS IVUS enables reproducible lumen measurements in stents and reference sections. The degree of stent expansion, however, underlies a high measurement variability that can lead to different therapeutic strategies.
Collapse
Affiliation(s)
- E Blessing
- Division of Cardiology, Hannover Medical School, Hannover, Germany
| | | | | | | | | | | |
Collapse
|
27
|
Moses JW, Undermir C, Strain JE, Kreps EM, Higgins JE, Gleim GW, Kern MJ. Relation between single tomographic intravascular ultrasound image parameters and intracoronary Doppler flow velocity in patients with intermediately severe coronary stenoses. Am Heart J 1998; 135:988-94. [PMID: 9630102 DOI: 10.1016/s0002-8703(98)70063-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Intravascular ultrasound (IVUS) imaging parameters have been suggested as criteria to determine coronary lesion significance before intervention. However, there has not been a systematic examination of combined anatomic and physiologic data in the same patients with coronary artery disease. METHODS AND RESULTS To examine the relation between coronary flow reserve and IVUS parameters, 41 patients with intermediately severe coronary artery stenoses had measurements of coronary flow velocity (0.014-inch Doppler flow wire), coronary flow velocity reserve (CVR) (hyperemic/basal mean flow), IVUS imaging (2.9F, Cardiovascular Imaging Systems, Inc.), and quantitative coronary angiography before intervention. Correlations between physiologic and anatomic parameters were performed by simple regression. Results were also examined by patient subgroups with CVR > 1.8 or < 1.8 to assess differences in IVUS parameters. The angiographic percent diameter stenosis was 52% +/- 17% (range 18% to 95%). Mean CVR was 1.88 +/- 0.56 (range 0.9 to 3.18). IVUS minimal luminal diameter (r = 0.312, p = 0.047) and angiographic percent stenosis (r = 3.05, p = 0.052) were weakly related to poststenotic CVR. Comparing patients with CVR < 1.8, IVUS reference segment area, IVUS lumen area, and angiographic percent diameter stenosis was higher (17.7 +/- 0.3 vs 12.9 +/- 4.4 mm2, p < 0.05; 6.20 +/- 3.76 vs 4.34 +/- 2.00 mm2, p < 0.05; and 60% +/- 14% vs 46% +/- 17%, p < 0.01, respectively) than in the group with CVR > 1.8. CONCLUSIONS Despite a precise determination of cross-sectional vessel areas and absolute dimensions by IVUS, single tomographic measurements did not correlate well with coronary physiologic responses. These data suggest that the physiologic data may be complementary to anatomic quantitative IVUS, enhancing information for coronary interventional decision making.
Collapse
Affiliation(s)
- J W Moses
- Section of Interventional Cardiology, Lenox Hill Hospital, New York, NY, USA
| | | | | | | | | | | | | |
Collapse
|
28
|
Abstract
Functional evaluation of coronary vasomotion encompasses the assessment of dynamic changes in coronary lumen, vessel wall, blood flow, intracoronary pressure and myocardial perfusion in response to specific pharmacologic stimuli. These parameters are obtained to characterize mechanisms of physiologic regulation and to evaluate pathophysiologic processes and potential therapeutic strategies, especially with regard to the development of coronary atherosclerosis. To this end, a variety of direct (invasive) and indirect (non-invasive) diagnostic tools are employed. Among the invasive methods are registration of intracoronary Doppler flow, coronary pressure measurements, quantitative coronary angiography and intravascular ultrasound. The non-invasive modalities consist of coronary Doppler echocardiography, positron emission tomography, myocardial scintigraphy and magnetic resonance imaging. Because of the different technical and physiological principles involved, these methods are complementary by providing independent access to different aspects. The combined invasive functional testing as employed in the cardiac catheterization laboratory allows for a simultaneous synopsis of high-resolution coronary imaging and direct measurement of physiologic parameters during local application of defined pharmacologically active substances. However, the demands in terms of equipment, time and operator skills are high and limit this combined invasive approach to specialized centers. Besides these research purposes, a number of functional methods has entered the clinical arena. They are employed to evaluate the hemodynamic significance of coronary lesions and to assess functional outcome of therapeutic interventions in the catheterization laboratory. The underlying principles and applications of the different methods are described and an overview of selected results is presented.
Collapse
Affiliation(s)
- M Elsner
- Medizinische Klinik IV (Kardiologie/Nephrologie), Johann-Wolfgang-Goethe-Universität Frankfurt.
| |
Collapse
|
29
|
von Birgelen C, de Vrey EA, Mintz GS, Nicosia A, Bruining N, Li W, Slager CJ, Roelandt JR, Serruys PW, de Feyter PJ. ECG-gated three-dimensional intravascular ultrasound: feasibility and reproducibility of the automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans. Circulation 1997; 96:2944-52. [PMID: 9386161 DOI: 10.1161/01.cir.96.9.2944] [Citation(s) in RCA: 143] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND Automated systems for the quantitative analysis of three-dimensional (3D) sets of intravascular ultrasound (IVUS) images have been developed to reduce the time required to perform volumetric analyses; however, 3D image reconstruction by these nongated systems is frequently hampered by cyclic artifacts. METHODS AND RESULTS We used an ECG-gated 3D IVUS image acquisition workstation and a dedicated pullback device in atherosclerotic coronary segments of 30 patients to evaluate (1) the feasibility of this approach of image acquisition, (2) the reproducibility of an automated contour detection algorithm in measuring lumen, external elastic membrane, and plaque+media cross-sectional areas (CSAs) and volumes and the cross-sectional and volumetric plaque+media burden, and (3) the agreement between the automated area measurements and the results of manual tracing. The gated image acquisition took 3.9+/-1.5 minutes. The length of the segments analyzed was 9.6 to 40.0 mm, with 2.3+/-1.5 side branches per segment. The minimum lumen CSA measured 6.4+/-1.7 mm2, and the maximum and average CSA plaque+media burden measured 60.5+/-10.2% and 46.5+/-9.9%, respectively. The automated contour-detection required 34.3+/-7.3 minutes per segment. The differences between these measurements and manual tracing did not exceed 1.6% (SD<6.8%). Intraobserver and interobserver differences in area measurements (n=3421; r=.97 to.99) were <1.6% (SD<7.2%); intraobserver and interobserver differences in volumetric measurements (n=30; r=.99) were <0.4% (SD<3.2%). CONCLUSIONS ECG-gated acquisition of 3D IVUS image sets is feasible and permits the application of automated contour detection to provide reproducible measurements of the lumen and atherosclerotic plaque CSA and volume in a relatively short analysis time.
Collapse
Affiliation(s)
- C von Birgelen
- Thoraxcenter, Division of Cardiology, University Hospital Rotterdam-Dijkzigt and Erasmus University, The Netherlands
| | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Takagi T, Yoshida K, Akasaka T, Hozumi T, Morioka S, Yoshikawa J. Intravascular ultrasound analysis of reduction in progression of coronary narrowing by treatment with pravastatin. Am J Cardiol 1997; 79:1673-6. [PMID: 9202362 DOI: 10.1016/s0002-9149(97)00221-x] [Citation(s) in RCA: 97] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Serial intravascular ultrasound studies were performed to evaluate the effect of pravastatin on coronary atherosclerotic plaque. Administration of pravastatin reduced serum lipid levels and progression of coronary artery atherosclerotic plaque.
Collapse
Affiliation(s)
- T Takagi
- Division of Cardiology, Kobe General Hospital, Chuo-ku, Japan
| | | | | | | | | | | |
Collapse
|
31
|
Kern MJ, Dupouy P, Drury JH, Aguirre FV, Aptecar E, Bach RG, Caracciolo EA, Donohue TJ, Rande JL, Geschwind HJ, Mechem CJ, Kane G, Teiger E, Wolford TL. Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: a combined intravascular ultrasound Doppler flow and imaging study. J Am Coll Cardiol 1997; 29:1520-7. [PMID: 9180114 DOI: 10.1016/s0735-1097(97)00082-x] [Citation(s) in RCA: 88] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVES This study sought to examine the mechanism of increasing coronary flow reserve after balloon angioplasty and stenting. BACKGROUND Coronary vasodilatory reserve (CVR) does not improve after percutaneous transluminal coronary angioplasty in > or = 50% of patients, postulated to be due to impaired microvascular circulation or inadequate lumen expansion despite adequate angiographic results. METHODS To demonstrate the role of coronary lumen expansion, serial coronary flow velocity (0.014-in. Doppler guide wire) was measured in 42 patients before and after balloon angioplasty and again after stent placement. A subset (n = 17) also underwent intravascular ultrasound (IVUS) imaging of the target sites after angioplasty and stenting. CVR (velocity) was computed as the ratio of adenosine-induced maximal hyperemic to basal average peak velocity. RESULTS The percent diameter stenosis decreased from (mean +/- SD) 84 +/- 13% to 37 +/- 18% after angioplasty and to 8 +/- 8% after stenting (both p < 0.05). CVR was minimally changed from 1.70 +/- 0.79 at baseline to 1.89 +/- 0.56 (p = NS) after angioplasty but increased to 2.49 +/- 0.68 after stent placement (p < 0.01 vs. before and after angioplasty). IVUS lumen cross-sectional area was significantly larger after stenting than after angioplasty (8.39 +/- 2.09 vs. 5.10 +/- 2.03 mm2, p < 0.05). Anatomic variables were related to increasing coronary flow velocity reserve (CVR vs. IVUS lumen area: r = 0.47, p < 0.005; CVR vs. quantitative coronary angiographic percent area stenosis: r = 0.58, p < 0.0001). CONCLUSIONS In most cases, increases in CVR were associated with increases in coronary lumen cross-sectional area. These data suggest that impaired CVR after angioplasty is often related to the degree of residual narrowing, which at times may not be appreciated by angiography. A physiologically complemented approach to balloon angioplasty may improve procedural outcome.
Collapse
Affiliation(s)
- M J Kern
- Department of Internal Medicine, Saint Louis University, Missouri 63110, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Mehra MR, Ventura HO, Stapleton DD, Karsan AK, Smart FW, Ramee SR, Collins TJ. Allograft aortopathy: an in vivo study of donor aorta involvement in cardiac allograft vasculopathy. Am Heart J 1997; 133:698-702. [PMID: 9200398 DOI: 10.1016/s0002-8703(97)70172-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Limited histopathologic studies of failed cardiac allografts have demonstrated that cardiac allograft vasculopathy extends into the donor aorta; however, no study has examined the development of allograft aortic intimal proliferation in vivo in conjunction with coronary intimal hyperplasia. By using simultaneous intracoronary and intraaortic ultrasound, we studied 20 consecutive heart transplant recipients at 2.5 +/- 2.1 years after transplantation. The degree of coronary intimal thickening was strongly correlated with the development of intraaortic intimal hyperplasia (r = 0.90; p < 0.0001). Multivariate predictors of aortic intimal thickening included years after transplant (r = 0.47; p = 0.03), serum cholesterol level (r = 0.65, p = 0.003), and serum triglyceride level (r = 0.51; p = 0.03). Allograft aortopathy occurs in a similar manner to allograft coronary disease, thus providing support for the notion that an immunologic stimulus operating across the allograft vascular bed may be responsible for the development of cardiac allograft vasculopathy. Furthermore, this investigation provides insight into the putative role of hyperlipidemia in allograft vascular disease.
Collapse
Affiliation(s)
- M R Mehra
- Department of Internal Medicine, Ochsner Medical Institutions, New Orleans, La. 70121, USA
| | | | | | | | | | | | | |
Collapse
|
33
|
Kofoed KF, Czernin J, Johnson J, Kobashigawa J, Phelps ME, Laks H, Schelbert HR. Effects of cardiac allograft vasculopathy on myocardial blood flow, vasodilatory capacity, and coronary vasomotion. Circulation 1997; 95:600-6. [PMID: 9024146 DOI: 10.1161/01.cir.95.3.600] [Citation(s) in RCA: 60] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND Coronary vasculopathy is the third leading cause of death 1 year after cardiac allograft transplantation. This study was designed to assess the hemodynamic effects of transplant vasculopathy on myocardial blood flow and vasomotion. METHODS AND RESULTS Thirty-two patients were studied 1 to 2 years after cardiac transplantation by use of positron emission tomography (n = 32), intravascular ultrasound (n = 26), coronary angiography (n = 32), and endomyocardial biopsy (n = 32). Twenty healthy individuals served as control subjects. Quantitative intravascular ultrasound was used to compute coronary lumen area, intimal thickness, and intimal index [Intima Area/(Intima + Lumen Area)]. Myocardial blood flow was quantified with the use of 13N-ammonia/positron emission tomography. Mean myocardial blood flow was higher in the transplant patients than in control subjects (0.94 +/- 0.26 versus 0.68 +/- 0.16 mL.min-1.g-1 P < .0005). Cold increased myocardial blood flow to 0.79 +/- 0.18 mL.min-1.g-1 in control subjects but not in patients (0.98 +/- 0.36 mL.g-1.min-1). Hyperemic myocardial blood flow was lower in patients than in control subjects (1.69 +/- 0.78 versus 2.30 +/- 0.32 mL.min-1.g-1; P < .05) and was inversely related to maximal intimal thickness and intimal index (all P < .05). The myocardial flow reserve was reduced in patients (1.82 +/- 0.55 versus 3.45 +/- 1.03; P < .0001). CONCLUSIONS The degree of intimal thickening is correlated with abnormalities in coronary function in patients with diffuse cardiac allograft vasculopathy. The reduction in vasodilatory capacity and the abnormal blood flow response to cold suggest abnormalities in endothelium-dependent and -independent coronary vasodilation in transplant recipients.
Collapse
Affiliation(s)
- K F Kofoed
- Department of Molecular and Medical Pharmacology, UCLA School of Medicine 90024-1721, USA
| | | | | | | | | | | | | |
Collapse
|
34
|
Schwarzacher SP, Honda Y, Metz JA, Asvar CA, Fitzgerald PJ, Yock PG. Impact of curve distortion errors on intravascular ultrasound measurements and three-dimensional reconstructions. Am J Cardiol 1997; 79:384-7. [PMID: 9036768 DOI: 10.1016/s0002-9149(97)89287-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Intravascular ultrasound distortion errors and longitudinal reconstructions are primarily determined by the angle of curvature. The error in commonly encountered angles is relatively small.
Collapse
Affiliation(s)
- S P Schwarzacher
- Center for Research in Cardiovascular Interventions, Stanford University School of Medicine, California 94305, USA
| | | | | | | | | | | |
Collapse
|
35
|
Foster GP, Mittleman MA, Koch M, Abela G, Zarich SW. Variability in the measurement of intracoronary ultrasound images: implications for the identification of atherosclerotic plaque regression. Clin Cardiol 1997; 20:11-5. [PMID: 8994732 PMCID: PMC6655378 DOI: 10.1002/clc.4960200105] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/1996] [Accepted: 08/09/1996] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND AND HYPOTHESIS Serial coronary angiography cannot reliably detect the small changes in arterial dimensions. Measurement of arterial dimensions by intracoronary ultrasound (ICUS) may be a superior method to determine the extent of atherosclerotic burden since it directly images the diseased portion of the vessel. METHODS To quantify inter- and intraobserver variability of ICUS measurements, 27 images of atherosclerotic coronary lesions were measured by two study physicians and repeated 14 days later. RESULTS Interobserver correlation coefficients for external elastic lamina, lumen, and effective plaque area were 0.96, 0.99, and 0.91, respectively. Intraobserver correlation coefficients for external elastic lamina, lumen, and effective plaque area were 0.99, 0.99, and 0.97, respectively. To determine progression or regression in effective plaque area, a minimal difference of 2.77 mm2 (which represents a 23% change in plaque area) is needed. CONCLUSIONS Direct visualization of the extent of atherosclerosis by ICUS can be accomplished with a low degree of inter- and intraobserver variability. ICUS may be a preferable alternative to angiography in atherosclerosis regression trials.
Collapse
Affiliation(s)
- G P Foster
- Institute for Prevention of Cardiovascular Disease, Deaconess Hospital, Bridgeport, Connecticut, USA
| | | | | | | | | |
Collapse
|
36
|
von Birgelen C, van der Lugt A, Nicosia A, Mintz GS, Gussenhoven EJ, de Vrey E, Mallus MT, Roelandt JR, Serruys PW, de Feyter PJ. Computerized assessment of coronary lumen and atherosclerotic plaque dimensions in three-dimensional intravascular ultrasound correlated with histomorphometry. Am J Cardiol 1996; 78:1202-9. [PMID: 8960575 DOI: 10.1016/s0002-9149(96)00596-6] [Citation(s) in RCA: 52] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Intravascular ultrasound (IVUS), which depicts both lumen and plaque, offers the potential to improve on the limitations of angiography for the assessment of the natural history of atherosclerosis and progression or regression of the disease. To facilitate measurements and increase the reproducibility of quantitative IVUS analyses, a computerized contour detection system was developed that detects both the luminal and external vessel boundaries in 3-dimensional sets of IVUS images. To validate this system, atherosclerotic human coronary segments (n = 13) with an area obstruction > or = 40% (40% to 61%) were studied in vitro by IVUS. The computerized IVUS measurements (areas and volumes) of the lumen, total vessel, plaque-media complex, and percent obstruction were compared with findings by manual tracing of the IVUS images and of the corresponding histologic cross sections obtained at 2-mm increments (n = 100). Both area and volume measurements by the contour detection system agreed well with the results obtained by manual tracing, showing low mean between-method differences (-3.7% to 0.3%) with SDs not exceeding 6% and high correlation coefficients (r = 0.97 to 0.99). Measurements of the lumen, total vessel, plaque-media complex, and percent obstruction by the contour detection system correlated well with histomorphometry of areas (r = 0.94, 0.88, 0.80, and 0.88) and volumes (r = 0.98, 0.91, 0.83, and 0.91). Systematic differences between the results by the contour detection system and histomorphometry (29%, 13%, -9%, and -22%, respectively) were found, most likely resulting from shrinkage during tissue fixation. The results of this study indicate that this computerized IVUS analysis system is reliable for the assessment of coronary atherosclerosis in vivo.
Collapse
Affiliation(s)
- C von Birgelen
- Thoraxcenter, University Hospital Rotterdam-Dijkzigt, Erasmus University, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
von Birgelen C, Di Mario C, Li W, Schuurbiers JC, Slager CJ, de Feyter PJ, Roelandt JR, Serruys PW. Morphometric analysis in three-dimensional intracoronary ultrasound: an in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaque. Am Heart J 1996; 132:516-27. [PMID: 8800020 DOI: 10.1016/s0002-8703(96)90233-1] [Citation(s) in RCA: 108] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Currently, automated systems for quantitative analysis by intracoronary ultrasound (ICUS) are restricted to the detection of the lumen. The aim of this study was to determine the accuracy and reproducibility of a new semiautomated contour detection method, providing off-line identification of the intimal leading edge and external contour of the vessel in three-dimensional ICUS. The system allows cross-sectional and volumetric quantification of lumen and of plaque. It applies a minimum-cost algorithm and the concept that edge points derived from previously detected longitudinal contours guide and facilitate the contour detection in the cross-sectional images. A tubular phantom with segments of various luminal dimensions was examined in vitro during five catheter pull-backs (1 mm/sec), and subsequently 20 diseased human coronary arteries were studied in vivo with 2.9F 30 MHz mechanical ultrasound catheters (200 images per 20 mm segment). The ICUS measurements of phantom lumen area and volume revealed a high correlation with the true phantom areas and volumes (r = 0.99); relative mean differences were -0.65% to 3.86% for the areas and 0.25% to 1.72% for the volumes of the various segments. Intraob-server and interobserver comparisons showed high correlations (r = 0.95 to 0.98 for area and r = 0.99 for volume) and small mean relative differences (-0.87% to 1.08%), with SD of lumen, plaque, and total vessel measurements not exceeding 7.28%, 10.81%, and 4.44% (area) and 2.66%, 2.81%, and 0.67% (volume), respectively. Thus the proposed analysis system provided accurate measurements of phantom dimensions and can be used to perform highly reproducible area and volume measurements in three-dimensional ICUS in vivo.
Collapse
Affiliation(s)
- C von Birgelen
- Thoraxcenter, University Hospital Rotterdam, Dijkzig, Erasmus University, The Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
38
|
von Birgelen C, Gil R, Ruygrok P, Prati F, Di Mario C, van der Giessen WJ, de Feyter PJ, Serruys PW. Optimized expansion of the Wallstent compared with the Palmaz-Schatz stent: on-line observations with two- and three-dimensional intracoronary ultrasound after angiographic guidance. Am Heart J 1996; 131:1067-75. [PMID: 8644583 DOI: 10.1016/s0002-8703(96)90078-2] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Optimized stent expansion by high-pressure inflations of oversized balloons has initially been derived from experience obtained with the Palmaz-Schatz stent, whereas there is little experience with this strategy in the Wallstent. By using this approach with quantitative coronary angiographic guidance, 20 Wallstents and 20 Palmaz-Schatz stents were implanted in 34 patients and consecutively examined by conventional two-dimensional (2D) intracoronary ultrasound (ICUS) and three-dimensional (3D) ICUS on the basis of the application of a pattern recognition algorithm. Ultrasound criteria of adequate stent expansion were defined as a complete apposition of the stent to the vessel wall, a stent symmetry index (SSI = minimum/maximum lumen diameter) > or = O.7, and a stent-reference lumen area ratio (SRR = Minimum intrastent lumen area/Average of proximal and distal reference lumen area) > or = O.8. In all cases a smooth angiographic lumen and a negative diameter stenosis, on the basis of a distal reference, was achieved. For the Wallstents ICUS showed a higher SSI (2D, 0.95 +/- 0.04 vs 0.85 +/- 0.09; p < 0.001; 3D, 0.90 +/- 0.09 vs 0.82 +/- 0.11, p < 0.05) and a lower SRR (2D, 0.66 +/- 0.12 vs 0.81 +/- 0.13, p < 0.005; 3D, 0.63 +/- 0.14 vs 0.74 +/- 0.15, p < 0.05) than for the Palmaz-Schatz stents. Ninety percent of failure in meeting these criteria resulted from a low SRR. The incidence of incomplete stent apposition (one in both stents) or SSI <0.7 was low and generally associated with an SRR <0.8. The Wallstents met the ICUS criteria less often (2D, 2(1O%) vs 10(50%), p < 0.01; 3D, 3(15%) vs 9(45%), p < 0.05), were significantly longer (35.1 +/- 7.7 mm and 14.3 +/- 3.3 mm, p < 0.0001), and generally demonstrated a larger vessel tapering, measured as proximal minus distal ICUS reference lumen area (1.33 +/- 2.91 mm2 vs 0.44 +/- 1.97 mm(2), not significant). Wallstents meeting the ICUS criteria, however, showed less vessel tapering (0.18 +/- 1.64 mm(2)). Thus optimized stent expansion was followed by excellent angiographic results for both Palmaz-Schatz and Wallstent. Although angiographic results and visual assessment of the ICUS examination suggested a good outcome, few Wallstents met the ICUS criteria in contrast to the Palmaz-Schatz stents. The low value of the SRR in the Wallstents is likely to be caused by vessel tapering, suggesting that this criterion may be unsuitable in assessing the adequacy of the expansion of relatively long stents such as the Wallstent.
Collapse
Affiliation(s)
- C von Birgelen
- Thoraxcenter, Division of Cardiology, University Hospital, Erasmus University, Rotterdam, The Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
39
|
Gil R, von Birgelen C, Prati F, Di Mario C, Ligthart J, Serruys PW. Usefulness of three-dimensional reconstruction for interpretation and quantitative analysis of intracoronary ultrasound during stent deployment. Am J Cardiol 1996; 77:761-4. [PMID: 8651131 DOI: 10.1016/s0002-9149(97)89214-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
We examined 49 coronary stents in 33 patients after angiographically guided optimization of the deployment by intracoronary ultrasound, and compared the findings of a conventional 2-dimensional analysis approach with the results obtained from an automatic lumen recognition provided by a 3-dimensional reconstruction system. The automatic lumen analysis demonstrated that only 15 stents (31%) fulfilled defined ultrasound criteria of adequate stent deployment, and that 5 of these cases were missed by the conventional approach, which systematically overestimated the dimensions of the minimal stent lumen.
Collapse
Affiliation(s)
- R Gil
- Intracoronary Imaging Laboratory and Cardiac Catheterization Laboratory, Thoraxcenter, Rotterdam, The Netherlands
| | | | | | | | | | | |
Collapse
|
40
|
Mcconnell MV, Ganz P, Lee RT, Selwyn AP, Libby P. Imaging atherosclerosis: lesion vs. lumen. ACTA ACUST UNITED AC 1996. [DOI: 10.1007/978-94-009-0291-6_7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2023]
|
41
|
van der Lugt A, Gussenhoven EJ, Pasterkamp G, Bom N, Posthuma DJ, Stijnen T. Interobserver reproducibility of qualitative and quantitative analysis of intravascular ultrasound images before and after peripheral balloon angioplasty. ULTRASOUND IN MEDICINE & BIOLOGY 1996; 22:399-404. [PMID: 8795166 DOI: 10.1016/0301-5629(96)00034-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
In this study, interobserver agreement on intravascular ultrasound data obtained before and after balloon angioplasty (PTA) of the superficial femoral artery was assessed. Two observers analyzed intravascular ultrasound cross-sections from 38 patients. Interobserver agreement was good for soft and hard lesions, dissection and vascular damage (kappa values 0.61, 0.67, 0.69 and 0.66, respectively); moderate for eccentric lesions (kappa 0.45); fair for media ruptures (kappa 0.25); and poor for lipid deposits and plaque ruptures (kappa 0.0 and 0.04, respectively). Differences for the arc of normal wall and hard lesion were not significant, but were for dissection. There were no significant interobserver differences between area measurements. The coefficient of variation for free lumen area and media-bounded area before PTA was 17.2% and 10.5% and after PTA 11.2% and 9.2%, respectively. This study identified the intravascular ultrasound parameters that are reproducible.
Collapse
|
42
|
Kearney PP, Starkey IR, Sutherland GR. Intracoronary ultrasound: current state of the art. BRITISH HEART JOURNAL 1995; 73:16-25. [PMID: 7612393 PMCID: PMC483895 DOI: 10.1136/hrt.73.5_suppl_2.16] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Affiliation(s)
- P P Kearney
- Department of Cardiology, Western General Hospital, Edinburgh
| | | | | |
Collapse
|