• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4635060)   Today's Articles (1106)   Subscriber (50028)
For: Di Mario C, Meneveau N, Gil R, de Jaegere P, de Feyter PJ, Slager CJ, Roelandt JR, Serruys PW. Maximal blood flow velocity in severe coronary stenoses measured with a Doppler guidewire. Limitations for the application of the continuity equation in the assessment of stenosis severity. Am J Cardiol 1993;71:54D-61D. [PMID: 8488776 DOI: 10.1016/0002-9149(93)90134-x] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Number Cited by Other Article(s)
1
Caiati C, Stanca A, Lepera ME. Assessment of the Severity of Left Anterior Descending Coronary Artery Stenoses by Enhanced Transthoracic Doppler Echocardiography: Validation of a Method Based on the Continuity Equation. Diagnostics (Basel) 2023;13:2526. [PMID: 37568889 PMCID: PMC10417389 DOI: 10.3390/diagnostics13152526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 06/16/2023] [Accepted: 07/25/2023] [Indexed: 08/13/2023]  Open
2
Zhou J, Onuma Y, Garg S, Kotoku N, Kageyama S, Masuda S, Ninomiya K, Huo Y, Reiber JHC, Tu S, Piek JJ, Escaned J, Perera D, Bourantas C, Yan H, Serruys PW. Angiography derived assessment of the coronary microcirculation: is it ready for prime time? Expert Rev Cardiovasc Ther 2022;20:549-566. [PMID: 35899781 DOI: 10.1080/14779072.2022.2098117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
3
Agrawal A, Raval A, Velhal S, Patel V, Patravale V. Nanoparticles eluting stents for coronary intervention: Formulation, characterization and in vitro evaluation. Can J Physiol Pharmacol 2021;100:220-233. [PMID: 34570985 DOI: 10.1139/cjpp-2021-0245] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
4
Pruessmann K, Wentzlaff M, Schilling R, Seidlitz A. Influence of Dissolution Vessel Geometry and Dissolution Medium on In Vitro Dissolution Behaviour of Triamterene-Coated Model Stents in Different Test Setups. AAPS PharmSciTech 2019;20:27. [PMID: 30604074 DOI: 10.1208/s12249-018-1227-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2018] [Accepted: 10/21/2018] [Indexed: 11/30/2022]  Open
5
Kempin W, Kaule S, Reske T, Grabow N, Petersen S, Nagel S, Schmitz KP, Weitschies W, Seidlitz A. In vitro evaluation of paclitaxel coatings for delivery via drug-coated balloons. Eur J Pharm Biopharm 2015;96:322-8. [PMID: 26318979 DOI: 10.1016/j.ejpb.2015.08.010] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Revised: 08/12/2015] [Accepted: 08/21/2015] [Indexed: 11/30/2022]
6
In vitro study of sirolimus release from a drug-eluting stent: Comparison of the release profiles obtained using different test setups. Eur J Pharm Biopharm 2015;93:328-38. [DOI: 10.1016/j.ejpb.2015.04.016] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 04/11/2015] [Accepted: 04/26/2015] [Indexed: 11/21/2022]
7
Bandomir J, Kaule S, Schmitz KP, Sternberg K, Petersen S, Kragl U. Usage of different vessel models in a flow-through cell: in vitro study of a novel coated balloon catheter. RSC Adv 2015. [DOI: 10.1039/c4ra12524j] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]  Open
8
Semmling B, Nagel S, Sternberg K, Weitschies W, Seidlitz A. Impact of different tissue-simulating hydrogel compartments on in vitro release and distribution from drug-eluting stents. Eur J Pharm Biopharm 2014;87:570-8. [DOI: 10.1016/j.ejpb.2014.04.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2013] [Revised: 03/13/2014] [Accepted: 04/27/2014] [Indexed: 12/21/2022]
9
Semmling B, Nagel S, Sternberg K, Weitschies W, Seidlitz A. Development of hydrophobized alginate hydrogels for the vessel-simulating flow-through cell and their usage for biorelevant drug-eluting stent testing. AAPS PharmSciTech 2013;14:1209-18. [PMID: 23918507 DOI: 10.1208/s12249-013-0011-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2013] [Accepted: 07/15/2013] [Indexed: 11/30/2022]  Open
10
Semmling B, Nagel S, Sternberg K, Weitschies W, Seidlitz A. Long-term stable hydrogels for biorelevant dissolution testing of drug-eluting stents. ACTA ACUST UNITED AC 2013. [DOI: 10.7243/2050-120x-2-19] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
11
Bernad SI, Bernad ES, Craina M, Sargan I, Totoran A, Brisan C. Particle depositions and related hemodynamic parameters in the multiple stenosed right coronary artery. J Clin Med Res 2012;4:177-89. [PMID: 22719804 PMCID: PMC3376876 DOI: 10.4021/jocmr843w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/07/2012] [Indexed: 11/03/2022]  Open
12
Seidlitz A, Weitschies W. In-vitro dissolution methods for controlled release parenterals and their applicability to drug-eluting stent testing. J Pharm Pharmacol 2012;64:969-85. [DOI: 10.1111/j.2042-7158.2011.01439.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
13
Joutsiniemi E, Saraste A, Pietilä M, Ukkonen H, Kajander S, Mäki M, Koskenvuo J, Airaksinen J, Hartiala J, Saraste M, Knuuti J. Resting coronary flow velocity in the functional evaluation of coronary artery stenosis: study on sequential use of computed tomography angiography and transthoracic Doppler echocardiography. Eur Heart J Cardiovasc Imaging 2011;13:79-85. [PMID: 21880607 DOI: 10.1093/ejechocard/jer153] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]  Open
14
Sato H, Okamura M, Kurogane K, Takeuchi Y, Ota T, Okada M. Assessment of flow velocity in saphenous vein graft using the Doppler guidewire. Int J Angiol 2011. [DOI: 10.1007/bf02043459] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]  Open
15
Seidlitz A, Nagel S, Semmling B, Grabow N, Martin H, Senz V, Harder C, Sternberg K, Schmitz KP, Kroemer HK, Weitschies W. Examination of drug release and distribution from drug-eluting stents with a vessel-simulating flow-through cell. Eur J Pharm Biopharm 2010;78:36-48. [PMID: 21182943 DOI: 10.1016/j.ejpb.2010.12.021] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2010] [Revised: 12/08/2010] [Accepted: 12/09/2010] [Indexed: 10/18/2022]
16
Krüger D, ElMokhtari NE, Wieckhorst A, Simon-Herrmann G, Simon R. Intravascular ultrasound study and evidence of pathological coronary flow reserve in patients with isolated coronary artery aneurysms. Clin Res Cardiol 2010;99:157-64. [DOI: 10.1007/s00392-009-0100-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2009] [Accepted: 12/08/2009] [Indexed: 10/20/2022]
17
Local Drug Delivery Systeme. BIOMED ENG-BIOMED TE 2010. [DOI: 10.1515/bmt.2010.710] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
18
Implantate. BIOMED ENG-BIOMED TE 2010. [DOI: 10.1515/bmt.2010.709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
19
Caiati C, Zedda N, Cadeddu M, Chen L, Montaldo C, Iliceto S, Lepera ME, Favale S. Detection, location, and severity assessment of left anterior descending coronary artery stenoses by means of contrast-enhanced transthoracic harmonic echo Doppler. Eur Heart J 2009;30:1797-806. [DOI: 10.1093/eurheartj/ehp163] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]  Open
20
Neubert A, Sternberg K, Nagel S, Harder C, Schmitz KP, Kroemer HK, Weitschies W. Development of a vessel-simulating flow-through cell method for the in vitro evaluation of release and distribution from drug-eluting stents. J Control Release 2008;130:2-8. [DOI: 10.1016/j.jconrel.2008.05.012] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2008] [Revised: 05/07/2008] [Accepted: 05/09/2008] [Indexed: 11/28/2022]
21
Oldenburg O, Philipp T, Forsting M, Erbel R. Percutaneous, Catheter-Based Coil Embolization of Coronary Fistula:. J Interv Cardiol 2003;16:343-6. [PMID: 14562676 DOI: 10.1034/j.1600-6143.2003.08053.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]  Open
22
Chen JW, Hsu NW, Wu TC, Lin SJ, Chang MS. Long-term angiotensin-converting enzyme inhibition reduces plasma asymmetric dimethylarginine and improves endothelial nitric oxide bioavailability and coronary microvascular function in patients with syndrome X. Am J Cardiol 2002;90:974-82. [PMID: 12398965 DOI: 10.1016/s0002-9149(02)02664-4] [Citation(s) in RCA: 148] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
23
Heverhagen JT, Hoppe M, Klose KJ, Wagner HJ. Does the application of gadolinium-DTPA have an impact on magnetic resonance phase contrast velocity measurements? Results from an in vitro study. Eur J Radiol 2002;44:65-9. [PMID: 12350415 DOI: 10.1016/s0720-048x(01)00425-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
24
Yang Y, Bartel T, Eggebrecht H, Latina L, von Birgelen C, Caspari G, Wang X, Erbel R. Non-invasive assessment of coronary flow velocity reserve: a new method using transthoracic Doppler echocardiography. Curr Med Sci 2002;22:158-63. [PMID: 12658763 DOI: 10.1007/bf02857683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2001] [Indexed: 10/19/2022]
25
Hwang CW, Wu D, Edelman ER. Physiological transport forces govern drug distribution for stent-based delivery. Circulation 2001;104:600-5. [PMID: 11479260 DOI: 10.1161/hc3101.092214] [Citation(s) in RCA: 262] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
26
Alfke H, Heverhagen JT, Bandorski D, Hoppe M, Wagner HJ. Prospective comparison of MR phase-contrast velocimetry with intravascular doppler US during infrainguinal artery angioplasty. J Vasc Interv Radiol 2001;12:459-63. [PMID: 11287533 DOI: 10.1016/s1051-0443(07)61885-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
27
Al Suwaidi J, Higano ST, Holmes DR, Rihal CS, Lerman A. Measuring maximal percent area stenosis poststent placement with intracoronary Doppler and the continuity equation and correlation with intracoronary ultrasound and angiography. Am J Cardiol 1999;84:650-4. [PMID: 10498133 DOI: 10.1016/s0002-9149(99)00410-5] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
28
Bartel T, Müller S, Baumgart D, Mathew BT, Haude M, Erbel R. Improved high-frequency transthoracic flow velocity measurement in the left anterior descending coronary artery after intravenous peripheral injection of levovist. J Am Soc Echocardiogr 1999;12:252-6. [PMID: 10196502 DOI: 10.1016/s0894-7317(99)70039-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
29
Hoppe M, Heverhagen JT, Froelich JJ, Kunisch-Hoppe M, Klose KJ, Wagner HJ. Correlation of flow velocity measurements by magnetic resonance phase contrast imaging and intravascular Doppler ultrasound. Invest Radiol 1998;33:427-32. [PMID: 9704280 DOI: 10.1097/00004424-199808000-00001] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
30
Isaaz K, da Costa A, de Pasquale JP, Cerisier A, Lamaud M. Use of the continuity equation for transesophageal Doppler assessment of severity of proximal left coronary artery stenosis: a quantitative coronary angiography validation study. J Am Coll Cardiol 1998;32:42-8. [PMID: 9669247 DOI: 10.1016/s0735-1097(98)00174-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
31
Klues HG, Schwarz ER, vom Dahl J, Reffelmann T, Reul H, Potthast K, Schmitz C, Minartz J, Krebs W, Hanrath P. Disturbed intracoronary hemodynamics in myocardial bridging: early normalization by intracoronary stent placement. Circulation 1997;96:2905-13. [PMID: 9386156 DOI: 10.1161/01.cir.96.9.2905] [Citation(s) in RCA: 137] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
32
Mandinov L, Kaufmann P, Staub D, Buckingham TA, Amann FW, Hess OM. Coronary vasomotion after percutaneous transluminal coronary angioplasty depends on the severity of the culprit lesion. J Am Coll Cardiol 1997;30:682-8. [PMID: 9283526 DOI: 10.1016/s0735-1097(97)00212-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
33
Altstidl R, Regenfus M, Lehmkuhl H, Dill H, Bachmann K. Evaluation of successful PTCA by transstenotic flow velocity ratios. Angiology 1997;48:775-82. [PMID: 9313627 DOI: 10.1177/000331979704800904] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
34
Sarry L, Boire JY, Zanca M, Lusson JR, Cassagnes J. Assessment of stenosis severity using a novel method to estimate spatial and temporal variations of blood flow velocity in biplane coronarography. Phys Med Biol 1997;42:1549-64. [PMID: 9279905 DOI: 10.1088/0031-9155/42/8/006] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
35
HIGANO STUARTT, LERMAN AMIR, GARRATT KIRKN, NISHIMURA RICKA, HOLMES DAVIDR. Assessing Coronary Flow Physiology with Intracoronary Doppler Following Coronary Interventions. J Interv Cardiol 1996. [DOI: 10.1111/j.1540-8183.1996.tb00611.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]  Open
36
Hoppe M, Wagner HJ, Klose KJ. Assessment of the hemodynamic result of PTA with a Doppler guide wire: initial experience. J Vasc Interv Radiol 1996;7:89-93. [PMID: 8773980 DOI: 10.1016/s1051-0443(96)70739-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]  Open
37
Pijls NH, Van Gelder B, Van der Voort P, Peels K, Bracke FA, Bonnier HJ, el Gamal MI. Fractional flow reserve. A useful index to evaluate the influence of an epicardial coronary stenosis on myocardial blood flow. Circulation 1995;92:3183-93. [PMID: 7586302 DOI: 10.1161/01.cir.92.11.3183] [Citation(s) in RCA: 535] [Impact Index Per Article: 18.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
38
Ge J, Erbel R, Zamorano J, Haude M, Kearney P, Görge G, Meyer J. Improvement of coronary morphology and blood flow after stenting. Assessment by intravascular ultrasound and intracoronary Doppler. INTERNATIONAL JOURNAL OF CARDIAC IMAGING 1995;11:81-7. [PMID: 7673762 DOI: 10.1007/bf01844705] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
39
Kern MJ, Tron C, Donohue TJ, Bach RG, Caracciolo EA, Aguirre FV, Labovitz AJ. Hemodynamic significance of coronary jet velocity in patients: limitations of the Bernouilli equation in small conduits. Am Heart J 1995;129:887-94. [PMID: 7732977 DOI: 10.1016/0002-8703(95)90108-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
40
Di Mario C, von Birgelen C, Prati F, Soni B, Li W, Bruining N, de Jaegere PP, de Feyter PJ, Serruys PW, Roelandt JR. Three dimensional reconstruction of cross sectional intracoronary ultrasound: clinical or research tool? Heart 1995;73:26-32. [PMID: 7612394 PMCID: PMC483900 DOI: 10.1136/hrt.73.5_suppl_2.26] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]  Open
41
Keegan J, Firmin D, Gatehouse P, Longmore D. The application of breath hold phase velocity mapping techniques to the measurement of coronary artery blood flow velocity: phantom data and initial in vivo results. Magn Reson Med 1994;31:526-36. [PMID: 8015406 DOI: 10.1002/mrm.1910310509] [Citation(s) in RCA: 78] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA