1
|
Isbell TA, Strickland EC, Hitchcock J, McIntire G, Colyer CL. Capillary electrophoresis-mass spectrometry determination of morphine and its isobaric glucuronide metabolites. J Chromatogr B Analyt Technol Biomed Life Sci 2015; 980:65-71. [DOI: 10.1016/j.jchromb.2014.11.035] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2014] [Revised: 11/20/2014] [Accepted: 11/29/2014] [Indexed: 10/24/2022]
|
2
|
Soria AC, Wright B, Goodall DM, Wilson J. Data processing in metabolic fingerprinting by CE-UV: Application to urine samples from autistic children. Electrophoresis 2007; 28:950-64. [PMID: 17370305 DOI: 10.1002/elps.200600381] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Metabolic fingerprinting of biofluids such as urine can be used to detect and analyse differences between individuals. However, before pattern recognition methods can be utilised for classification, preprocessing techniques for the denoising, baseline removal, normalisation and alignment of electropherograms must be applied. Here a MEKC method using diode array detection has been used for high-resolution separation of both charged and neutral metabolites. Novel and generic algorithms have been developed for use prior to multivariate data analysis. Alignment is achieved by combining the use of reference peaks with a method that uses information from multiple wavelengths to align electropherograms to a reference signal. This metabolic fingerprinting approach by MEKC has been applied for the first time to urine samples from autistic and control children in a nontargeted and unbiased search for markers for autism. Although no biomarkers for autism could be determined using MEKC data here, the general approach presented could also be applied to the processing of other data collected by CE with UV-Vis detection.
Collapse
Affiliation(s)
- Ana C Soria
- Department of Chemistry, University of York, York, UK
| | | | | | | |
Collapse
|
3
|
Abstract
One of the weak points of capillary electrophoresis is the need to implement rigorously sample pretreatment because its great impact on the quality of the qualitative and quantitative results provided. One of the approaches to solve this problem is through the symbiosis of automatic continuous flow systems (CFSs) and capillary electrophoresis (CE). In this review a systematic approach to CFS-CE coupling is presented and discussed. The design of the corresponding interface depends on three factors, namely: (a) the characteristics of the CFS involved which can be non-chromatographic and chromatographic; (b) the type of CE equipment: laboratory-made or commercially available; and (c) the type of connection which can be in-line (on-capillary), on-line or mixed off/on-line. These are the basic criteria to qualify the hyphenation of CFS (solid-phase extraction, dialysis, gas diffusion, evaporation, direct leaching) with CE described so far and applied to determine a variety of analytes in many different types of samples. A critical discussion allows one to demonstrate that this symbiosis is an important topic in research and development, besides separation and detection, to consolidate CE as a routine analytical tool.
Collapse
Affiliation(s)
- M Valcárcel
- Analytical Chemistry Division, University of Córdoba, Spain.
| | | | | |
Collapse
|
4
|
Abstract
A capillary electrophoresis-mass spectrometry (CE-MS) method for the analysis of quaternary ammonium drugs in equine urine was developed. Quaternary ammonium drugs were first extracted from equine urine by ion-pair extraction and then analysed by CE-MS in the positive electrospray ionization (ESI) mode. Within 12 min, eight quaternary ammonium drugs, each at 1 ng/mL in horse urine, could be detected. The confirmation of these drugs in urine samples was achieved by capillary electrophoresis tandem mass spectrometry (CE-MS/MS). A direct comparison of this method was made with existing liquid chromatography/mass spectrometry (LC-MS) methods in the detection and confirmation of glycopyrrolate and ipratropium bromide in horse urine. While the two drugs could be detected within the same CE-MS run at 1 ng/mL in urine, they could only be detected in separate LC-MS runs at 5 ng/mL in urine. In addition, CE-MS consumed a much smaller volume of extract; the analyte peak widths, in some cases, were much narrower; and as the quaternary ammonium ions were well separated electrophoretically from the mainly neutral urine matrix, a much cleaner background in the CE-MS total ion trace was observed.
Collapse
Affiliation(s)
- F P Tang
- Racing Laboratory, The Hong Kong Jockey Club, Shatin, PR China
| | | | | |
Collapse
|
5
|
Wey AB, Thormann W. Capillary electrophoresis-electrospray ionization ion trap mass spectrometry for analysis and confirmation testing of morphine and related compounds in urine. J Chromatogr A 2001; 916:225-38. [PMID: 11382295 DOI: 10.1016/s0021-9673(00)01096-7] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Using an aqueous background electrolyte containing 25 mM ammonium acetate and NH3 (pH 9), CE-tandem MS and CE-triple MS with atmospheric pressure electrospray ionization in the positive ion mode are shown to represent attractive approaches for analysis and confirmation testing of morphine (MOR) and related opioids in human urine. Injection of plain or diluted urine permits monitoring of solutes at concentrations above 2-5 microg/ml. For the recognition of lower concentrations, solute extraction and concentration is required. Liquid-liquid extraction at alkaline pH is shown to be suitable for analysis of free opioids only whereas solid-phase extraction using a mixed-mode polymer phase is demonstrated to permit analysis of both free and glucuronidated opioids. The former sample preparation approach, however, requires about half of the time only. Commencing with 2 ml of urine, reconstitution to provide a sample volume of 0.2 ml and hydrodynamic sample injection, detection limits for free opioids are shown to be on the 100-200 ng/ml drug level. Much improved (ppb) sensitivity is obtained by infusing the extract directly into the source of the MS system. However, solutes that produce equal fragments (such as the two glucuronides of MOR) can thereby not be distinguished. CE-tandem MS and CE-triple MS are demonstrated to be suitable to confirm the presence of MOR, MOR-3-glucuronide, 6-monoacetylmorphine, codeine, codeine-6-glucuronide, dihydrocodeine, methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine in a toxicological quality control urine. The same is shown for selected metabolites of codeine and dihydrocodeine in urines collected after administration of pharmaceutical preparations.
Collapse
Affiliation(s)
- A B Wey
- Department of Clinical Pharmacology, University of Berne, Switzerland
| | | |
Collapse
|
6
|
Keski-Hynnilä H, Raana K, Taskinen J, Kostiainen R. Direct analysis of nitrocatechol-type glucuronides in urine by capillary electrophoresis-electrospray ionisation mass spectrometry and tandem mass spectrometry. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2000; 749:253-63. [PMID: 11145062 DOI: 10.1016/s0378-4347(00)00413-8] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Direct, quantitative capillary electrophoresis-electrospray ionisation mass spectrometric (CE-ESI-MS) and tandem mass spectrometric (CE-ESI-MS-MS) methods are described for the quantitation of 3-O-glucuronides of E- and Z-entacapone isomers (EEG and EZG) and tolcapone (TG) in urine. 3-O-Glucuronide of nitecapone was used as internal standard. Good separation of glucuronides was achieved with 20 mM ammonium acetate as separation solution at pH 6.84. Stacking was used to increase the sensitivity of the method by introducing samples in 5 mM ammonium acetate. CE-ESI-MS and CE-ESI-MS-MS methods are linear with correlation coefficients better than 0.9983 and 0.9982, and repeatable with relative standard deviations below 9 and 14%, respectively. The limit of detection (LOD) in CE-ESI-MS at signal-to-noise ratio 3 is 100 ng/ml for EEG and EZG and 250 ng/ml for TG. The CE-ESI-MS-MS method was the more sensitive; LOD was 7 ng/ml for all compounds, without any concentration of the sample.
Collapse
|
7
|
Veraart JR, Lingeman H, Brinkman UA. Coupling of biological sample handling and capillary electrophoresis. J Chromatogr A 1999; 856:483-514. [PMID: 10526801 DOI: 10.1016/s0021-9673(99)00588-9] [Citation(s) in RCA: 108] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The analysis of biological samples (e.g., blood, urine, saliva, tissue homogenates) by capillary electrophoresis (CE) requires efficient sample preparation (i.e., concentration and clean-up) procedures to remove interfering solutes (endogenous/exogenous and/or low-/high-molecular-mass), (in)organic salts and particulate matter. The sample preparation modules can be coupled with CE either off-line (manual), at-line (robotic interface), on-line (coupling via a transfer line) or in-line (complete integration between sample preparation and separation system). Sample preparation systems reported in the literature are based on chromatographic, electrophoretic or membrane-based procedures. The combination of automated sample preparation and CE is especially useful if complex samples have to be analyzed and helps to improve both selectivity and sensitivity. In this review, the different modes of solid-phase (micro-) extraction will be discussed and an overview of the potential of chromatographic, electrophoretic (e.g., isotachophoresis, sample stacking) and membrane-based procedures will be given.
Collapse
Affiliation(s)
- J R Veraart
- Vrije Universiteit, Department of Analytical Chemistry and Applied Spectroscopy, Amsterdam, The Netherlands.
| | | | | |
Collapse
|
8
|
Boone CM, Waterval JC, Lingeman H, Ensing K, Underberg WJ. Capillary electrophoresis as a versatile tool for the bioanalysis of drugs--a review. J Pharm Biomed Anal 1999; 20:831-63. [PMID: 10746954 DOI: 10.1016/s0731-7085(99)00088-6] [Citation(s) in RCA: 65] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
This review article presents an overview of current research on the use of capillary electrophoretic techniques for the analysis of drugs in biological matrices. The principles of capillary electrophoresis and its various separation and detection modes are briefly discussed. Sample pretreatment methods which have been used for clean-up and concentration are discussed. Finally, an extensive overview of bioanalytical applications is presented. The bioanalyses of more than 200 drugs have been summarised, including the applied sample pretreatment methods and the achieved detection limits.
Collapse
Affiliation(s)
- C M Boone
- Department of Analytical Chemistry and Toxicology, University Center for Pharmacy, Groningen, The Netherlands.
| | | | | | | | | |
Collapse
|
9
|
Abstract
Separation of morphine and its oxidation products (10-S-hydroxymorphine, pseudomorphine and morphine N-oxide) by capillary zone electrophoresis in Tris-borate buffer in the presence of cyclodextrins was studied. Pyridoxine was used as an internal standard.
Collapse
Affiliation(s)
- B Proksa
- Slovakofarma a.s., Hlohovec, Slovak Republic.
| |
Collapse
|
10
|
Affiliation(s)
- D Perrett
- Department of Medicine, St Bartholomew's, London, UK
| |
Collapse
|
11
|
Bohnenstengel F, Kroemer HK, Sperker B. In vitro cleavage of paracetamol glucuronide by human liver and kidney beta-glucuronidase: determination of paracetamol by capillary electrophoresis. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 1999; 721:295-9. [PMID: 10052702 DOI: 10.1016/s0378-4347(98)00464-2] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
A capillary electrophoresis (CE) method was developed using paracetamol glucuronide as a novel probe for human beta-glucuronidase activity. Using UV detection without prior sample clean-up procedures, fast and reliable quantitation of the released paracetamol was possible. The method showed good precision, accuracy and sensitivity with a limit of detection of 0.25 microM (38 ng/ml) and a limit of quantitation of 1 microM (151 ng/ml). The suitability of the method has been shown for enzyme kinetic studies using different liver and kidney homogenates, respectively. Our data clearly demonstrate that paracetamol glucuronide is cleaved by human beta-glucuronidase thereby releasing paracetamol. The CE method presented is not only a valuable tool for measuring human beta-glucuronidase activity, but also allows investigation of the contribution of deglucuronidation of paracetamol glucuronide to the disposition of paracetamol.
Collapse
Affiliation(s)
- F Bohnenstengel
- Dr. Margarete Fischer-Bosch Institute of Clinical Pharmacology, Stuttgart, Germany
| | | | | |
Collapse
|
12
|
Wätzig H, Degenhardt M, Kunkel A. Strategies for capillary electrophoresis: method development and validation for pharmaceutical and biological applications. Electrophoresis 1998; 19:2695-752. [PMID: 9870372 DOI: 10.1002/elps.1150191603] [Citation(s) in RCA: 157] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
This review is in support of the development of selective, reproducible and validated capillary electrophoretis (CE) methods. Focusing on pharmaceutical and biological applications, the successful use of CE is demonstrated by more than 800 references, mainly from 1994 until 1998. Approximately 80 recent reviews have been catalogued. These articles sum up the existing strategies for method development in CE, especially in the search for generally accepted concepts, but also looking for new, promising reagents and ideas. General strategies for method development were derived not only with regard to selectivity and efficiency, but also with regard to precision, short analysis time, limit of detection, sample pretreatment requirements and validation. Standard buffer recipes, surfactants used in micellar electrokinetic capillary chromatography (MEKC), chiral selectors, useful buffer additives, polymeric separation media, electroosmotic flow (EOF) modifiers, dynamic and permanent coatings, actions to deal with complex matrices and aspects of validation are collected in 20 tables. Detailed schemes for the development of MEKC methods and chiral separations, for optimizing separation efficiency, means of troubleshooting, and other important information for key decisions during method development are given in 19 diagrams. Method development for peptide and protein separations, possibilities to influence the EOF and how to stabilize it, as well as indirect detection are considered in special sections.
Collapse
Affiliation(s)
- H Wätzig
- Institut für Pharmazie und Lebensmittelchemie, Würzburg, Germany.
| | | | | |
Collapse
|
13
|
Taylor RB, Toasaksiri S, Reid RG. A literature assessment of sample pretreatments and limits of detection for capillary electrophoresis of drugs in biological fluids and practical investigation with some antimalarials in plasma. Electrophoresis 1998; 19:2791-7. [PMID: 9870375 DOI: 10.1002/elps.1150191606] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
A literature survey on published reports of the determination of drugs in biological fluids shows that all methods of sample pretreatment have been used and that the limits of detection achieved vary widely, ranging from low ngcm(-3) to microgcm(-3). The most widely used injection method was hydrodynamic and, in the majority of cases, whenever low detection limits were achieved, this was a result of preconcentration during the sample pretreatment. Only a small proportion of the reported methods employed electrokinetic injection and utilised the field amplified sample injection (FASI) techniques. An experimental investigation of the alternative hydrodynamic and electrokinetic injection methods for a small set of antimalarial drugs is reported. It was found that electrokinetic injection with FASI from an acetonitrile-water matrix produced dramatic improvements in detection limits. This improvement could not, however, be achieved when the drugs were in plasma using protein precipitation, liquid-liquid extraction or solid phase extraction pretreatment methods. This highlights the importance of sample pretreatment in utilising the potential sensitivity of capillary electrophoresis with electrokinetic injection.
Collapse
Affiliation(s)
- R B Taylor
- School of Pharmacy, The Robert Gordon University, Schoolhill, Aberdeen, UK.
| | | | | |
Collapse
|
14
|
Bedford CT. Glucuronic acid conjugates. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 1998; 717:313-26. [PMID: 9832252 DOI: 10.1016/s0378-4347(98)00328-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The methods of assay in body fluids of 1-beta-alkyl, 1-beta-phenyl and 1-beta-acyl glucuronic acids ("glucuronide conjugates") have been reviewed. Most of the 78 references cited (from the literature of the period 1990-1997) concern the glucuronide conjugates of drug metabolites, and these have been considered, for reasons of accessibility, within sections of individual drug classes such as analgesics, anti-cancer agents and opioids. Other glucuronide conjugates are considered under "miscellaneous compounds". A few gas chromatography and capillary electrophoresis methods are described, but the major technique of assay (62 citations) is reversed-phase high-performance liquid chromatography.
Collapse
Affiliation(s)
- C T Bedford
- Department of Biotechnology, University of Westminister, London, UK
| |
Collapse
|
15
|
Guzman NA, Park SS, Schaufelberger D, Hernandez L, Paez X, Rada P, Tomlinson AJ, Naylor S. New approaches in clinical chemistry: on-line analyte concentration and microreaction capillary electrophoresis for the determination of drugs, metabolic intermediates, and biopolymers in biological fluids. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 1997; 697:37-66. [PMID: 9342656 DOI: 10.1016/s0378-4347(97)00275-2] [Citation(s) in RCA: 94] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The use of capillary electrophoresis (CE) for clinically relevant assays is attractive since it often presents many advantages over contemporary methods. The small-diameter tubing that holds the separation medium has led to the development of multicapillary instruments, and simultaneous sample analysis. Furthermore, CE is compatible with a wide range of detectors, including UV-Vis, fluorescence, laser-induced fluorescence, electrochemistry, mass spectrometry, radiometric, and more recently nuclear magnetic resonance, and laser-induced circular dichroism systems. Selection of an appropriate detector can yield highly specific analyte detection with good mass sensitivity. Another attractive feature of CE is the low consumption of sample and reagents. However, it is paradoxical that this advantage also leads to severe limitation, namely poor concentration sensitivity. Often high analyte concentrations are required in order to have injection of sufficient material for detection. In this regard, a series of devices that are broadly termed 'analyte concentrators' have been developed for analyte preconcentration on-line with the CE capillary. These devices have been used primarily for non-specific analyte preconcentration using packing material of the C18 type. Alternatively, the use of very specific antibody-containing cartridges and enzyme-immobilized microreactors have been demonstrated. In the current report, we review the likely impact of the technology of capillary electrophoresis and the role of the CE analyte concentrator-microreactor on the analysis of biomolecules, present on complex matrices, in a clinical laboratory. Specific examples of the direct analysis of physiologically-derived fluids and microdialysates are presented, and a personal view of the future of CE in the clinical environment is given.
Collapse
Affiliation(s)
- N A Guzman
- R. W. Johnson Pharmaceutical Research Institute, Raritan, NJ 08869, USA
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Shihabi ZK, Friedberg MA. Analysis of small molecules for clinical diagnosis by capillary electrophoresis. Electrophoresis 1997; 18:1724-32. [PMID: 9372263 DOI: 10.1002/elps.1150181005] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The application of capillary electrophoresis (CE) for the analysis of small molecules in clinical research is growing steadily. Initial studies have dealt with separations of standards or compounds in clean matrices. However, later studies dealt with analysis of those compounds in serum, urine or tissues. Great progress has been accomplished in three areas of clinical interest: organic acids, amino acids and drug analysis. The analysis of these compounds by capillary electrophoresis has several distinct advantages: high resolution, simplicity, versatility and especially low operating costs. In many cases, the sample can be injected directly without complex pretreatment. Most of the described methods have been validated for their precision, linearity and accuracy. In forensic toxicology, the CE has been used for drug identification and as a complementary analytical method.
Collapse
Affiliation(s)
- Z K Shihabi
- Department of Pathology, Bowman Gray School of Medicine, Wake Forest University, Winston-Salem, NC 27157, USA.
| | | |
Collapse
|
17
|
Taylor MR, Westwood SA, Perrett D. Direct monitoring of enzyme reactions using micellar electrokinetic capillary chromatography. Optimisation of drug glucuronide and sulfate conjugate hydrolysis. J Chromatogr A 1997; 768:67-71. [PMID: 9175276 DOI: 10.1016/s0021-9673(96)00941-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
This paper demonstrates the use of micellar electrokinetic capillary chromatography (MECC) to monitor enzyme reaction conditions. The hydrolysis reactions of model conjugated substrates (morphine and reduced flunixin glucuronides, napthyl sulfate), by proprietary beta-glucuronidase preparations, were studied under varied experimental conditions. Reactions were carried out in autosampler vials with incubation in a thermostatted CE autosampler tray. MECC was performed using borax buffer (17.5 mM, pH 9.3) modified with sodium dodecyl sulfate (70 mM). Repetitive injections were made from the sample vial throughout the course of the reactions at a frequency of up to 10 h-1. MECC provided a rapid and reproducible assay for the model substrates. Baseline interference from the enzymes prevented measurement of product increase, therefore substrate decrease was measured from the peak areas. Monitoring of reactions in this way has proved valuable in the optimisation of hydrolysis conditions used in sample preparation for drug analysis. beta-Glucuronidase preparations from Helix pomatia were found to give the best performance of those evaluated in terms of deconjugation efficiency.
Collapse
Affiliation(s)
- M R Taylor
- Horseracing Forensic Laboratory, Suffolk, UK
| | | | | |
Collapse
|