Wang Z, Lao HM, Liu T, Li LQ, Li M, Wu YS. Labelled antibody-based one-step time-resolved fluoroimmunoassay for measurement of free thyroxine in serum. Ann Clin Biochem 2011; 48:550-7. [DOI: 10.1258/acb.2011.010242] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Background Valid assays measuring free thyroxine (FT4) must perform without bias despite large variations in the concentrations and affinities of serum thyroxine-binding proteins in the population. We developed a new, rapid one-step labelled-antibody time-resolved fluoroimmunoassay (TRFIA) for FT4. Methods Based on the heterologous combination of anti-T4 monoclonal antibody and triiodothyronine–immunoglobulin G conjugate, a one-step TRFIA for FT4 detection was established and compared with the two-step DELFIA® Free Thyroxine Assay. Matrix interference caused by endogenous binders and exogenous non-esterified fatty acids (NEFA) was also accessed in the proposed assay. Results The developed method generally took only one hour, had a detection limit of 0.6 pmol/L and a large linear range of 2.5–120 pmol/L. The inter- and intra-assay coefficients of variation were 3.5–6.6% and 4.4–9.8%, respectively. Results from 110 specimens showed apparent agreement with that from the DELFIA® FT4 Assay with the square of the correlation coefficient of 0.975. This assay indicated that there was no significant dependence on endogenous binders and displayed potential interference by exogenous NEFA up to 5 mmol/L. Conclusions The proposed one-step heterologous TRFIA FT4 assay possesses simplicity, accuracy, high sensitivity and exhibits great potential for FT4 measurement. The combination of heterologous immunoassay with TRFIA may be advantageous for FT4 immunoassay development.
Collapse
Affiliation(s)
- Zheng Wang
- Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, China
| | - Hai-Miao Lao
- Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, China
| | - Tiancai Liu
- Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, China
| | - Lai-Qing Li
- Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, China
| | - Ming Li
- Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, China
| | - Ying-Song Wu
- Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, China
| |
Collapse
|
3
|
Liu R, Chen F, Zou K, Yang T. One-step monoclonal antibody based enzyme-linked immunosorbent assay for direct determination of cortisol in serum. Hybridoma (Larchmt) 2011; 30:279-86. [PMID: 21707363 DOI: 10.1089/hyb.2010.0115] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Monoclonal antibodies to cortisol have obvious potential advantages as starting materials for assay systems to detect their levels in body fluids. This is very important for monitoring pituitary gland and adrenal functions. To develop a one-step competitive heterogeneous enzyme-linked immunosorbent assay (ELISA), a monoclonal anti-cortisol antibody was generated using a reasonably designed haptenic derivative. Cortisol-3-O-carboxymethyloxime was coupled to carrier protein bovine serum albumin (BSA) to enhance its immunogenicity. Spleen cells were prepared from a BALB/c mouse, which had repeatedly been immunized with a conjugate of cortisol-3-O-carboxymethyloxime-bovine serum albumin (cortisol-3-O-CMO-BSA), to be fused with SP2/0 myeloma cells. After one fusion experiment, four hybridoma clones secreting a practical antibody were established. One of the resulting monoclonal antibodies, 2C9D11B5, showed an affinity constant (Ka) of 1.4 × 10(10) M(-1) for cortisol and provided a practical calibration curve (limit of detection [LOD], 0.26 ng per assay) in this ELISA system employing cortisol-21-hemisuccinate-horseradish peroxidase (cortisol-21-HS-HRP) as a tracer. Cross-reactivities with related C-21 steroids were acceptably low: 11-deoxycortisol (3.5%), cortisone (0.47%), corticosterone (<0.01%), progesterone (<0.01%), 17-hydroxyprogesterone (1.2%), 6-hydroxycortisol (7.6%), and tetrahydrocortisol (<0.01%). The intra-assay and inter-assay coefficient of variations (CVs) ranged from 4.3% to 9.2% and 3.8% to 10.4 %, respectively. The analytical recoveries were 92.3% to 116.3%. Serum cortisol levels of healthy volunteers were determined after chilled acetone, stripped to be 292.76 ± 201.38 ng/mL (n=5), which are in the reference range.
Collapse
Affiliation(s)
- Rong Liu
- Medical Science College, China Three Gorges University, Yichang, Hubei, China
| | | | | | | |
Collapse
|
4
|
Brouwers E, L'homme R, Al-Maharik N, Lapcík O, Hampl R, Wähälä K, Mikola H, Adlercreutz H. Time-resolved fluoroimmunoassay for equol in plasma and urine. J Steroid Biochem Mol Biol 2003; 84:577-88. [PMID: 12767283 DOI: 10.1016/s0960-0760(03)00071-2] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
We present a method for the determination of the isoflavan equol in plasma and urine. This estrogenic isoflavan, which is formed by the action of the intestinal microflora, may have higher biological activity than its precursor daidzein. High urinary excretion of equol has been suggested to be associated with a reduction in breast cancer risk. The method is based on time-resolved fluoroimmunoassay, using a europium chelate as a label. After synthesis of 4'-O-carboxymethylequol the compound is coupled to bovine serum albumin (BSA), then used as antigen to immunize rabbits. The tracer with the europium chelate is synthesized using the same 4'-O-derivative of equol. After enzymatic hydrolysis (urine) or enzymatic hydrolysis and ether extraction (plasma) the immunoassay is carried out. The antiserum cross-reacted to variable extent with some isoflavonoids. For the plasma method the cross-reactivity does not seem to influence the results, which were highly specific. The overestimation of the values using the urine method (164%) compared to the results obtained by a gas chromatography-mass spectrometry (GC-MS) method is probably due to some influence of the matrix on the signal, and interference of structurally related compounds. It is suggested that plasma assays are used but if urine samples are measured a formula has to be used to correct the values making them comparable to the GC-MS results. The correlation coefficients between the time-resolved fluoroimmunoassay (TR-FIA) methods and GC-MS methods were high; r-values for the plasma and urine method, were 0.98 and 0.91, respectively. The intra-assay coefficient of variation (CV%) for the TR-FIA plasma and urine results at three different concentrations vary between 5.5-6.5 and 3.4-6.9, respectively. The inter-assay CV% varies between 5.4-9.7 and 7.4-7.7, respectively. The working ranges of the plasma and urine assay are 1.27-512 and 1.9-512nmol/l, respectively.
Collapse
Affiliation(s)
- Elke Brouwers
- Folkhälsan Research Center, Division of Clinical Chemistry, Institute for Preventive Medicine, Nutrition and Cancer, P.O. Box 63, University of Helsinki, FIN-00014 Helsinki, Finland
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Tuomola M, Harpio R, Mikola H, Knuuttila P, Lindström M, Mukkala VM, Matikainen MT, Lövgren T. Production and characterisation of monoclonal antibodies against a very small hapten, 3-methylindole. J Immunol Methods 2000; 240:111-24. [PMID: 10854606 DOI: 10.1016/s0022-1759(00)00179-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Monoclonal antibodies were produced against a very small (131.2 Da) hapten, 3-methylindole. Nine derivatives of 3-methylindole were synthesised with spacers ending in a carboxyl group, and coupled to immunogenic carriers and europium chelate labels. Almost all the antigens elicited an antihapten response, but the majority of the mAbs produced strongly recognised the spacer group and did not bind free 3-methylindole. However, specific antibodies were obtained with five immunogens. Specificity could be directed against the pyrrole ring by locating the bridging group to the aromatic moiety of the indole ring system. Any modification in the position 3 of the indole ring strongly hindered mAb binding to the compound, and the cross-reactivity of physiologically important compounds, such as tryptophan and tryptamine, was negligible for all of the mAbs. The developed hapten structures successfully focused antibody recognition to the important sub-determinants in the indole ring system. Similar constructs could also be useful in the development of antibodies against other indolic compounds.
Collapse
Affiliation(s)
- M Tuomola
- Department of Biotechnology, University of Turku, Finland.
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Wang GJ, Lapcík O, Hampl R, Uehara M, Al-Maharik N, Stumpf K, Mikola H, Wähälä K, Adlercreutz H. Time-resolved fluoroimmunoassay of plasma daidzein and genistein. Steroids 2000; 65:339-48. [PMID: 10802284 DOI: 10.1016/s0039-128x(00)00089-1] [Citation(s) in RCA: 87] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
We present a method for the determination of the phytoestrogens daidzein and genistein in plasma (serum). These weakly estrogenic isoflavones occur in soybeans and in smaller amounts in some other beans and plants. It has been suggested that they may afford protection against prostate and breast cancer. The method is based on time-resolved fluoroimmunoassay (TR-FIA) using a europium chelate as a label. After synthesis of 4'-O-carboxymethyl-daidzein and 4'-O-carboxymethyl-genistein the compounds are coupled to bovine serum albumin (BSA), then used as antigens to immunize rabbits. The tracers with the europium chelate are synthesized using the same 4'-O-derivative of the isoflavones. After enzymatic hydrolysis and ether extraction the immunoassay is carried out using the VICTOR 1420 multilabel counter (Wallac Oy, Turku, Finland). The antisera cross-reacted to some extent with some isoflavonoids but not with flavonoids. The cross-reactivity seems not to influence the results, which were highly specific for both compounds. The correlation coefficients between the TR-FIA methods and the reference method based on isotope dilution gas chromatography-mass spectrometry were high; r-values were about 0.95-0.99 depending on concentration. The intra-assay coefficients of variation (CV%) for daidzein and genistein at three different concentrations vary 3.2-4.5 and 3.2-4.1, respectively. The inter-assay CVs vary 5.0-6.3 and 4.5-5.3, respectively. The working ranges of the daidzein and genistein assays are 1.0-216 and 1.7-370 nmol/l, respectively. The plasma values (n = 80) of daidzein and genistein are very low in Finnish subjects (mean for daidzein, 3.8+/-6.8 and for genistein, 3.2+/-7.6 nmol/l; median value for daidzein 1.5 and for genistein 1.4 nmol/l).
Collapse
Affiliation(s)
- G J Wang
- Institute for Preventive Medicine, Nutrition and Cancer, Folkhälsan Research Center, Department of Clinical Chemistry, University of Helsinki, Helsinki, Finland
| | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Uehara M, Lapcík O, Hampl R, Al-Maharik N, Mäkelä T, Wähälä K, Mikola H, Adlercreutz H. Rapid analysis of phytoestrogens in human urine by time-resolved fluoroimmunoassay. J Steroid Biochem Mol Biol 2000; 72:273-82. [PMID: 10822017 DOI: 10.1016/s0960-0760(00)00045-5] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A time-resolved fluoroimmunoassay (TR-FIA), with europium labeled phytoestrogens as tracers, was developed for the quantitative determination of enterolactone, genistein and daidzein in human urine. The aim was to create a method for the screening of large populations in order to assess the possible correlations between the urinary levels and the risk of Western diseases. After the synthesis of the 5'-carboxymethoxy derivative of enterolactone and 4'-O-carboxymethyl derivatives of daidzein and genistein, the respective compound was coupled to bovine serum albumin and then used as an antigen in the immunization of rabbits. The same derivatives of the phytoestrogen were used in preparing the europium tracers. After the enzymatic hydrolysis, the TR-FIA was carried out using the Victor 1420 multilabel counter. The method has sufficient sensitivity to measure the phytoestrogens at concentrations even below 5 nmol/l. The intra- and inter-assay coefficients of variation, at three different concentrations, varied from 1.9 to 5.3 and from 2.4 to 9.7, respectively. We measured urinary enterolactone, genistein and daidzein in 215 samples from Finnish healthy women and found that more than 50% of the values ranged between 1 and 7, <0.1 and 0.6 and below 0.6 micromol/24 h, respectively. The TR-FIA method including only a hydrolysis step gave higher values than those measured by gas chromatography-mass spectrometry (GC-MS). However, the assay results by the present method showed strong correlation with those obtained by GC-MS. It is concluded that the TR-FIA is suitable for population screening of urinary phytoestrogens.
Collapse
Affiliation(s)
- M Uehara
- Institute for Preventive Medicine, Nutrition and Cancer, Folkhälsan Research Center, Department of Clinical Chemistry, University of Helsinki, PO Box 60, FIN-00014, Helsinki, Finland
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Basu A, Shrivastav TG. One step enzyme linked immunosorbent assay for direct estimation of serum cortisol. JOURNAL OF IMMUNOASSAY 2000; 21:39-50. [PMID: 10805317 DOI: 10.1080/01971520009349498] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
One step competitive enzyme linked immunosorbent assay (ELISA) for direct estimation of cortisol in human serum is described. Cortisol-3-O-carboxymethyl-oxime-bovine serum albumin (cortisol-3-O-CMO-BSA) was used as an immunogen and cortisol-21-hemisuccinate-horse radish peroxidase (cortisol-21-HS-HRP) was used as a tracer. To the cortisol antibody coated microtiter wells, standards or serum samples (25 microl) along with cortisol-HRP conjugate (100 microl) were incubated for 2 hours at 37 degrees C. Bound enzyme activity was measured by, using TMB/H2O2 as a substrate. In this new strategy, chilled acetone stripped pooled human serum and sodium salicylate were used for preparing the standards and blocking the cortisol binding globulin (CBG), respectively. The sensitivity of the assay was .28 microg/100ml. The intraassay and interassay coefficient of variations (CVs) were ranged from 1.3% to 9.3% and 6.8% to 12.3 %, respectively. The analytical recoveries were 94% to 101.5%. The serum cortisol values, obtained by this method were correlated well with those, obtained by radioimmunoassay; r=0.95 (n=52).
Collapse
Affiliation(s)
- A Basu
- Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, New Delhi, India
| | | |
Collapse
|
9
|
Meltola N, Jauria P, Saviranta P, Mikola H. Synthesis of novel europium-labeled estradiol derivatives for time-resolved fluoroimmunoassays. Bioconjug Chem 1999; 10:325-31. [PMID: 10346860 DOI: 10.1021/bc980013q] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The O-(5-carboxypentyl)-, O-(4-aminobutyl)-, O-(6-aminohexyl)oximes of 2- and 4-formylestradiol as well as the 4-carboxyethylthioether derivative of estradiol were synthesized. These estradiol derivatives were characterized using IR-, 1H-, and 13C NMR spectroscopy. All synthesized estradiol derivatives were labeled with europium chelates. These "tracers" were purified and tested in a competitive time-resolved fluoroimmunoassay with monoclonal antibody (SSI 57-2) raised against the 6-O-(carboxymethyl)oxime-bovine serum albumin derivative of estradiol. All the tested europium-labeled estradiol-4-derivatives were bound by the antibody, whereas tracers linked via position 2 were not recognized by this antibody. It was observed that tracers conjugated via C-4 gave more sensitive standard curves than tracers conjugated via C-6. Especially, the estradiol-4-thioether derivative was found to be highly useful in time-resolved fluoroimmunoassays of estradiol while using this antibody.
Collapse
Affiliation(s)
- N Meltola
- University of Turku, Medical Physics and Chemistry and Department of Biotechnology, P.O. Box 123, FIN-20521 Turku, Finland.
| | | | | | | |
Collapse
|
10
|
Adlercreutz H, Wang GJ, Lapcík O, Hampl R, Wähälä K, Mäkelä T, Lusa K, Talme M, Mikola H. Time-resolved fluoroimmunoassay for plasma enterolactone. Anal Biochem 1998; 265:208-15. [PMID: 9882394 DOI: 10.1006/abio.1998.2886] [Citation(s) in RCA: 121] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
We present a method for the determination of the lignan enterolactone in plasma (serum). This compound, produced by intestinal bacteria from matairesinol and secoisolariciresinol in fiber-rich food, is a biomarker related to the intake of a healthy diet. The method is based on time-resolved fluoroimmunoassay using a europium chelate as a label. After synthesis of 5'-O-carboxymethoxyenterolactone the compound is coupled to bovine serum albumin and then used as antigen in immunization of rabbits. The tracer with the europium chelate is synthesized using the same 5'-derivative of enterolactone. After enzymatic hydrolysis and ether extraction the immunoassay is carried out using the VICTOR 1420 multilabel counter (Wallac Oy, Turku, Finland). No antiserum cross-reactivity with available lignans, isoflavonoids, or flavonoids could be detected. The intraassay and interassay coefficients of variation at different concentrations vary 4.6-6.0 and 5.5-9.9, respectively. The working range of the assay is 1.5-540 nmol/liter. We measured enterolactone in serum/plasma of 224 Finnish subjects: 98.8% of the subjects had values <100 nmol/liter, 38.0% had 20-39.9 nmol/liter, and 34.4% had <20 nmol/liter.
Collapse
Affiliation(s)
- H Adlercreutz
- Institute for Preventive Medicine, Nutrition and Cancer, Helsinki, Finland
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Erkens JH, Dieleman SJ, Dressendörfer RA, Strasburger CJ. A time-resolved fluoroimmunoassay for cortisol in unextracted bovine plasma or serum with optimized procedures to eliminate steroid binding protein interference and to minimize non-specific streptavidin-europium binding. J Steroid Biochem Mol Biol 1998; 67:153-61. [PMID: 9877216 DOI: 10.1016/s0960-0760(98)00083-1] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
A time-resolved fluoroimmunoassay (TR-FIA) for human salivary cortisol was adapted for the measurement of cortisol in unextracted bovine blood plasma and serum. It has been demonstrated that the binding of cortisol binding plasma proteins (CBPP) to the cortisol-biotin primary probe cannot be eliminated by means of cortisol releasing agents. Complete inactivation of CBPP was achieved by heating water diluted samples for 30 min at 80 degrees C. The high non-specific binding (NSB) of the streptavidin-europium secondary probe, encountered during preliminary experiments, was shown to be caused by an interaction with bovine serum albumin (BSA) and could be reduced partly by the addition of heparin. It was also shown that the ability to bind streptavidin-europium nonspecifically is not a general property of proteins since bovine gamma-globulin and gelatin lack this behaviour. The advantage of a highly reduced NSB, resulting from the use of a BSA free assay buffer, is not limited to this particular assay but is also beneficial for other procedures based on specific measurement of streptavidin-europium fluorescence. The detection limit for a 20 microl sample was 0.5 ng/ml. The intra-assay coefficients of variation for control samples with cortisol concentrations of 71.1, 39.2 and 10.3 ng/ml were 8.2, 7.9 and 11.3% (n = 16). The corresponding inter-assay coefficients of variation were 7.3, 9.0 and 11.2% (n = 73). Correlation with a commercially available radioimmunoassay, preceded by diethylether extraction of the sample, was 0.97 (n = 88).
Collapse
Affiliation(s)
- J H Erkens
- Department of Reproduction, DLO-Institute for Animal Science and Health (ID-DLO), Lelystad, The Netherlands
| | | | | | | |
Collapse
|
12
|
Pajunen M, Saviranta P, Jauria P, Karp M, Pettersson K, Mäntsälä P, Lovgren T. Cloning, sequencing, expression and characterization of three anti-estradiol-17beta Fab fragments. BIOCHIMICA ET BIOPHYSICA ACTA 1997; 1351:192-202. [PMID: 9116033 DOI: 10.1016/s0167-4781(96)00202-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
In order provide data for a basic understanding of the mechanisms of antibody specificity and for the design of antibodies with desired properties, we have sequence-analysed three high affinity anti-estradiol-17beta monoclonal antibodies. All three monoclonal antibodies to estradiol-17beta had been raised by conjugation of the 6-carboxymethyloxime derivative to protein carrier. The genes encoding heavy (Fd) and light (L) chains of these three antibodies were cloned and sequenced. The sequenced antibody chains were found to be from 46.0 to 89.7% sequence identical to a monoclonal antibody (DB3) binding a related steroid, progesterone. The Fd and L chains were paired with all possible Fd-L combinations and the corresponding proteins were expressed in Escherichia coli and characterized for their binding (immunoreactivity) to estradiol-17beta. Under the lac promoter and using the pelB signal sequences the production levels of the soluble (total) heavy and light chain Fab fragment combinations in periplasm and in supernatant varied from 115 to 2207 microg/l, while the immunoreactivity percentages (IR%) varied from < 1 to 45%. The production levels and IR% were dependent on the first constant domain subclasses of the heavy chain as well as the Fd-L chain combination expressed.
Collapse
Affiliation(s)
- M Pajunen
- Department of Biotechnology, University of Turku, Finland.
| | | | | | | | | | | | | |
Collapse
|
13
|
Abstract
A simple and efficient method of derivatizing and labeling the terminal sugar ring of digoxin (and other steroid glycosides) is described. The terminal sugar ring was oxidized by periodate to dialdehyde, followed by a reaction with the aminooxy group of heterobifunctional spacer reagent. Usually, reductive amination is needed to stabilize the Schiff base-type compounds produced in reactions between amino and aldehyde groups. Here the oxime compounds produced are stable wherefore the reductive amination step can be avoided and the reaction gives high yields without significant side reactions. After characterization the digoxin dioxime derivatives formed were labeled with europium chelates. These labeled digoxin derivatives bearing one or two europium-containing chelates, coupled via different spacers, were purified and tested in a competitive time-resolved fluoroimmunoassay. Several digoxin-specific monoclonal antibodies were also tested to determine the most suitable antibody-tracer combination, which was then employed to develop a simple competitive time-resolved fluoroimmunoassay for digoxin.
Collapse
Affiliation(s)
- H Mikola
- Department of Chemistry, University of Turku, Finland
| | | |
Collapse
|
14
|
Kesner JS, Knecht EA, Krieg EF, Barnard G, Mikola HJ, Kohen F, Gani MM, Coley J. Validations of time-resolved fluoroimmunoassays for urinary estrone 3-glucuronide and pregnanediol 3-glucuronide. Steroids 1994; 59:205-11. [PMID: 8048153 DOI: 10.1016/0039-128x(94)90029-9] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Competitive time-resolved fluoroimmunoassays (FIAs) were developed for measuring 1,3,5(10)-estratrien-3-ol-17-one glucosiduronate (estrone 3-glucuronide, E(1)3G) and 5 beta-Pregnane-3 alpha,20 alpha-diol 3-glucosiduronate (pregnanediol 3-glucuronide, Pd3G) in unextracted urine. The assays are specific, detect 0.98 ng E(1)3G/mL and 0.035 microgram Pd3G/mL, measure 102.8 +/- 2.0% of E(1)3G and 93.6 +/- 2.9% of Pd3G added, and exhibit between and within assay coefficients of variation, respectively, of 5.3% and 7.1% for E(1)3G and 6.8% and 7.8% for Pd3G. The urine matrix does not interfere with the assay. Urinary steroid glucuronide profiles measured by these FIAs conform to those of urinary steroid glucuronides and serum estradiol and progesterone measured by other established immunoassays. These FIAs afford the advantages of non-radioisotopic procedures and urine sample collection (convenience, non-invasiveness, integration of pulsatile secretion) to evaluate menstrual function in epidemiological, medical, and athletic populations.
Collapse
Affiliation(s)
- J S Kesner
- Division of Biomedical and Behavioral Science, National Institute for Occupational Safety and Health, Cincinnati, Ohio 45226-1998
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Mikola H, Sundell AC, Hänninen E. Labeling of estradiol and testosterone alkyloxime derivatives with a europium chelate for time-resolved fluoroimmunoassays. Steroids 1993; 58:330-4. [PMID: 8212081 DOI: 10.1016/0039-128x(93)90093-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
O-Carboxymethyl, O-(4aminobutyl)-, and O-(6-aminohexyl)-oximes of 6-oxoestradiol and testosterone were labeled using a described general labeling method with a europium chelate. A stable amide or thiourea bond was formed between the europium label and carboxyl or amino derivative of the steroid, respectively. These labeled "tracers" were purified and briefly tested in a competitive time-resolved fluoroimmunoassay using monoclonal antibodies raised against O-(carboxymethyloxime)-bovine serum albumin derivatives of estradiol and testosterone. Only buffer-based standards were used in a model system for the testing. These studies indicate only minor functional differences while using these antibodies due to the length of the spacer arm, and a higher sensitivity in the clinically relevant standard range was reached with the longer spacers.
Collapse
Affiliation(s)
- H Mikola
- Wallac Chemical Laboratories, Turku, Finland
| | | | | |
Collapse
|