1
|
Oka S, Higuchi T, Furukawa H, Shimada K, Hashimoto A, Matsui T, Tohma S. False-positive detection of IgM anti-severe acute respiratory syndrome coronavirus 2 antibodies in patients with rheumatoid arthritis: Possible effects of IgM or IgG rheumatoid factors on immunochromatographic assay results. SAGE Open Med 2022; 10:20503121221088090. [PMID: 35342631 PMCID: PMC8949754 DOI: 10.1177/20503121221088090] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Accepted: 02/24/2022] [Indexed: 12/29/2022] Open
Abstract
Objectives: The severe acute respiratory syndrome coronavirus 2 causes coronavirus disease 2019. A serological test is conducted to determine prior infection by severe acute respiratory syndrome coronavirus 2. We investigated whether the results of anti-severe acute respiratory syndrome coronavirus 2 antibody tests are modified in patients with rheumatoid arthritis. Methods: Patients in Japan with rheumatoid arthritis were recruited at Sagamihara Hospital from July 2014 to October 2015 (n = 38; 2014 cohort) and at Tokyo Hospital from June to October 2020 (n = 93; 2020 cohort). Anti-severe acute respiratory syndrome coronavirus 2 antibodies were measured by electrochemiluminescence immunoassay or immunochromatographic assay. Results: Anti-severe acute respiratory syndrome coronavirus 2 antibodies were not detected in any of the samples from rheumatoid arthritis patients tested by electrochemiluminescence immunoassay. Anti-severe acute respiratory syndrome coronavirus 2 antibodies were detected by immunochromatographic assay in the 3 (7.9%) serum samples in the 2014 cohort and 15 (16.1%) serum samples in the 2020 cohort. The IgM rheumatoid factor levels were increased in rheumatoid arthritis patients with IgM anti-severe acute respiratory syndrome coronavirus 2 antibodies detected by immunochromatographic assay (mean ± standard deviation (IU/ml), 1223.0 ± 1308.7 versus 503.6 ± 1947.2; P = 0.0101). The levels of IgG rheumatoid factor were also upregulated in rheumatoid arthritis patients with IgM anti-severe acute respiratory syndrome coronavirus 2 antibodies detected by immunochromatographic assay (4.0 ± 0.7 versus 2.4 ± 0.9; P = 0.0013). Conclusion: The results of IgM anti-severe acute respiratory syndrome coronavirus 2 antibody testing by immunochromatographic assay are modified by IgM or IgG rheumatoid factors in rheumatoid arthritis patients.
Collapse
Affiliation(s)
- Shomi Oka
- Department of Rheumatology, National Hospital Organization Tokyo National Hospital, Kiyose, Japan.,Clinical Research Center for Allergy and Rheumatology, National Hospital Organization Sagamihara National Hospital, Sagamihara, Japan
| | - Takashi Higuchi
- Department of Rheumatology, National Hospital Organization Tokyo National Hospital, Kiyose, Japan.,Department of Nephrology, Ushiku Aiwa General Hospital, Ushiku, Japan
| | - Hiroshi Furukawa
- Department of Rheumatology, National Hospital Organization Tokyo National Hospital, Kiyose, Japan.,Clinical Research Center for Allergy and Rheumatology, National Hospital Organization Sagamihara National Hospital, Sagamihara, Japan
| | - Kota Shimada
- Department of Rheumatology, National Hospital Organization Sagamihara National Hospital, Sagamihara, Japan.,Department of Rheumatic Diseases, Tokyo Metropolitan Tama Medical Center, Fuchu, Japan
| | - Atsushi Hashimoto
- Department of Rheumatology, National Hospital Organization Sagamihara National Hospital, Sagamihara, Japan.,Department of Internal Medicine, Sagami Seikyou Hospital, Sagamihara, Japan
| | - Toshihiro Matsui
- Clinical Research Center for Allergy and Rheumatology, National Hospital Organization Sagamihara National Hospital, Sagamihara, Japan.,Department of Rheumatology, National Hospital Organization Sagamihara National Hospital, Sagamihara, Japan
| | - Shigeto Tohma
- Department of Rheumatology, National Hospital Organization Tokyo National Hospital, Kiyose, Japan.,Clinical Research Center for Allergy and Rheumatology, National Hospital Organization Sagamihara National Hospital, Sagamihara, Japan
| |
Collapse
|
2
|
Hübschen JM, Bork SM, Brown KE, Mankertz A, Santibanez S, Ben Mamou M, Mulders MN, Muller CP. Challenges of measles and rubella laboratory diagnostic in the era of elimination. Clin Microbiol Infect 2017; 23:511-515. [PMID: 28412379 DOI: 10.1016/j.cmi.2017.04.009] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2016] [Revised: 04/03/2017] [Accepted: 04/05/2017] [Indexed: 11/26/2022]
Abstract
The Member States of the WHO European Region adopted the goal of measles and rubella elimination more than 10 years ago, but so far only 21 of 53 countries have reached this target. Laboratory investigation of suspected cases is essential to support disease elimination efforts. Therefore, WHO maintains a network of accredited laboratories providing high-quality testing. Laboratory investigation heavily relies on specific IgM serology and increasingly on virus detection by reverse transcription (RT)-PCR, but other methods such as IgG avidity testing and genetic characterization of virus strains have gained in importance. In elimination settings, often few samples from suspected cases are available for testing, but testing proficiency must be maintained. The predictive value of an IgM-positive result decreases and other rash-fever disease aetiologies become more important. In addition, cases with a rash after measles/rubella vaccination or with mild disease after waning of vaccine-induced antibodies are seen more often. Thus, it is necessary to perform comprehensive and potentially time-consuming and costly investigations of every suspected case using quality-controlled laboratory methods. At the same time rapid feedback to public health officers is required for timely interventions. The introduction of new laboratory methods for comprehensive case investigations requires training of staff under the supervision of WHO-accredited reference laboratories and the definition of appropriate test algorithms. Clinical, laboratory, and epidemiological data are essential for final case classification and investigation of chains of transmission in the endgame of measles and rubella elimination.
Collapse
Affiliation(s)
- J M Hübschen
- WHO European Regional Reference Laboratory for Measles and Rubella, Department of Infection and Immunity, Luxembourg Institute of Health, Esch-sur-Alzette and Laboratoire National de Santé, Dudelange, Luxembourg
| | - S M Bork
- WHO European Regional Reference Laboratory for Measles and Rubella, Department of Infection and Immunity, Luxembourg Institute of Health, Esch-sur-Alzette and Laboratoire National de Santé, Dudelange, Luxembourg
| | - K E Brown
- WHO Global Specialized Laboratory for Measles and Rubella, Virus Reference Department, Public Health England, London, UK
| | - A Mankertz
- WHO European Regional Reference Laboratory for Measles and Rubella, Robert Koch Institute, Berlin, Germany
| | - S Santibanez
- WHO European Regional Reference Laboratory for Measles and Rubella, Robert Koch Institute, Berlin, Germany
| | - M Ben Mamou
- Vaccine-Preventable Diseases and Immunization, WHO Regional Office for Europe, Copenhagen, Denmark
| | - M N Mulders
- Expanded Programme on Immunization, Department of Immunization, Vaccines, and Biologicals, WHO, Geneva, Switzerland
| | - C P Muller
- WHO European Regional Reference Laboratory for Measles and Rubella, Department of Infection and Immunity, Luxembourg Institute of Health, Esch-sur-Alzette and Laboratoire National de Santé, Dudelange, Luxembourg.
| |
Collapse
|
3
|
Xu L, Wang X, Ma R, Zeng X, Wu B, Hu L, Li Y. False decrease of HBsAg S/CO values in serum with high-concentration rheumatoid factors. Clin Biochem 2013; 46:799-804. [PMID: 23537796 DOI: 10.1016/j.clinbiochem.2013.03.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2013] [Revised: 03/12/2013] [Accepted: 03/15/2013] [Indexed: 10/27/2022]
Abstract
OBJECTIVES To investigate whether high-concentration RFs cause false decrease of S/CO values of serum HBsAg. DESIGN AND METHODS Serum HBsAg was determined in 100 RF-positive sera using one-step ELISA. Twenty-three HBsAg-negative sera with high-concentration RFs were selected randomly to perform dilution with mixed normal sera. Serum models consisting of HBsAg and high-concentration RFs were made by blending high-concentration RFs and HBsAg-positive sera at the ratio of 9:1. RESULTS In the 23 samples, one-step ELISA showed that HBsAg-positive rate was 69.57% at dilution of 1:2, 60.87% at dilution of 1:4 and 40.00% at dilution of 1:8, whereas two-step ELISA showed that it was 100% without any dilution. Thirty serum models were made and divided into six groups. Median S/CO value of HBsAg was 3.00 in control, whereas it ranged from 0.13 to 1.78 in the six groups. CONCLUSIONS High-concentration RFs cause false decrease of S/CO values of HBsAg using one-step ELISA.
Collapse
Affiliation(s)
- Lei Xu
- Laboratory Department, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | | | | | | | | | | | | |
Collapse
|
4
|
Lee JS, Kim EJ, Lynch KL, Elicker B, Ryerson CJ, Katsumoto TR, Shum AK, Wolters PJ, Cerri S, Richeldi L, Jones KD, King TE, Collard HR. Prevalence and clinical significance of circulating autoantibodies in idiopathic pulmonary fibrosis. Respir Med 2012. [PMID: 23186614 DOI: 10.1016/j.rmed.2012.10.018] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
BACKGROUND The clinical significance of circulating autoantibodies in idiopathic pulmonary fibrosis is unclear. The objective of this study was to determine the frequency and clinical significance of circulating autoantibodies in idiopathic pulmonary fibrosis. METHODS We measured an extensive panel of autoantibodies (including rheumatoid factor, anti-cyclic citrullinated peptide, and anti-nuclear antibodies by immunofluorescence) associated with connective tissue disease or vasculitis in a cohort of well-characterized patients with idiopathic pulmonary fibrosis (n = 67). The prevalence of circulating autoantibodies was compared between idiopathic pulmonary fibrosis patients and healthy controls (n = 52). We compared the clinical characteristics of patients with and without circulating autoantibodies, and analyzed the relationship between autoantibody positivity and transplant-free survival time. RESULTS Positive autoantibodies were found in 22% of patients with IPF and 21% of healthy controls. There were no differences in the types of autoantibodies found between patients with idiopathic pulmonary fibrosis and healthy controls. Among patients with idiopathic pulmonary fibrosis, there were no significant differences in clinical characteristics between those with and without circulating autoantibodies. The presence of circulating autoantibodies was associated with longer transplant-free survival time on adjusted analysis, however the significance varied depending on which statistical model was used (HR 0.22-0.47, p value 0.02-0.17). CONCLUSIONS The frequency of circulating autoantibodies in patients with idiopathic pulmonary fibrosis is no different compared to healthy controls, but may be associated with longer survival.
Collapse
Affiliation(s)
- Joyce S Lee
- Department of Medicine at University of California, San Francisco, 505 Parnassus Avenue, Box 0111, San Francisco, CA 94143, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Somers K, Stinissen P, Somers V. Optimization of High-throughput Autoantibody Profiling for the Discovery of Novel Antigenic Targets in Rheumatoid Arthritis. Ann N Y Acad Sci 2009; 1173:92-102. [PMID: 19758137 DOI: 10.1111/j.1749-6632.2009.04654.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Klaartje Somers
- Hasselt University, Biomedical Research Institute, and Transnationale Universiteit Limburg, School of Life Sciences, Agoralaan, Building C, 3590 Diepenbeek, Belgium
| | | | | |
Collapse
|
6
|
Wood WG. “Matrix Effects” in Immunoassays. Scandinavian Journal of Clinical and Laboratory Investigation 2009. [DOI: 10.3109/00365519109104608] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
7
|
Double-antigen enzyme-linked immunosorbent assay for detection of hepatitis E virus-specific antibodies in human or swine sera. CLINICAL AND VACCINE IMMUNOLOGY : CVI 2008; 15:1151-7. [PMID: 18495846 DOI: 10.1128/cvi.00186-07] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
A new double-antigen sandwich-based enzyme-linked immunosorbent assay (ELISA) for the detection of total antibodies (immunoglobulin G [IgG] and IgM) specific for hepatitis E virus (HEV) was developed by utilizing well-characterized recombinant protein ET2.1 and its peroxidase-labeled counterpart. Our study showed that the ELISA detected all the positive patient samples (n = 265) regardless of whether they contained IgM or IgG antibodies, or both, while it maintained an excellent specificity of 98.8% with samples from various patient or healthy control groups (total number of samples, 424). The test had a detection limit for anti-HEV IgG antibodies that was equivalent to 62 mIU/ml of the international reference. Compared with the serological status of the specimens determined on the basis of tests performed at the individual collection sites, the testing outcome generated by the new ELISA had a good agreement of 99.3%, with a kappa value of 0.985. The positive predictive value and the negative predictive value for the new test reached 98.1% and 100%, respectively. This ELISA had a positive delta value of 4.836 and a negative delta value of 3.314 (where delta is a measure of the number of standard deviations by which the cutoff is separated from the mean of the sample groups) (N. Crofts, W. Maskill, and I. D. Gust, J. Virol. Methods 22:51-59, 1988), indicating that it had an excellent ability to differentiate the infected and noninfected cohorts. Furthermore, the new design enables the detection of antibodies not only in human samples but also in pig samples. Our preliminary data showed that the ELISA could detect seroconversion in samples from pigs at as early as 14 days postinoculation. The potential utility of detecting specific antibodies in pigs will be an added advantage for managing the disease, with suggested zoonotic implications.
Collapse
|
8
|
Chen HY, Lu Y, Howard T, Anderson D, Fong PY, Hu WP, Chia CP, Guan M. Comparison of a new immunochromatographic test to enzyme-linked immunosorbent assay for rapid detection of immunoglobulin m antibodies to hepatitis e virus in human sera. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY 2005; 12:593-8. [PMID: 15879020 PMCID: PMC1112076 DOI: 10.1128/cdli.12.5.593-598.2005] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
An immunochromatographic test for rapid detection of IgM antibodies in patients with acute hepatitis E infection was developed utilizing the well-characterized recombinant protein EP2.1 and monoclonal antibody 4B2. The new rapid test based on a novel reverse-flow technology was able to generate a positive result within 2 to 3 min. Our study showed that this test was able to detect anti-HEV IgM antibodies in 96.7% of the patient samples tested (n = 151) while maintaining an excellent specificity of 98.6% with samples from various patient or healthy control groups (total n = 208). Furthermore, this rapid test gave a good specificity of 90.9% when tested with rheumatoid factor (RF)-positive sera (RF value of < or =850 IU/ml; n = 11) although a higher concentration of RF in samples might cause cross-reactivity. The new test has a good agreement of 97.2% with a kappa value of 0.943 when compared with a reference enzyme-linked immunosorbent assay. The positive predictive value and the negative predictive value for the rapid test thus reached 98.0 and 97.6%, respectively. This is the first rapid, point-of-care test for hepatitis E and will be especially useful for the diagnosis of acute hepatitis E virus infection in field and emergency settings and in resource-poor countries.
Collapse
Affiliation(s)
- Hsiao Ying Chen
- Genelabs Diagnostics Pte. Ltd., Product Development, 85 Science Park Drive 04-01, Singapore Science Park, Singapore 118259, Republic of Singapore
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Tuuminen T, Seppänen H, Pitkänen EM, Palomäki P, Käpyaho K. Improvement of immunoglobulin M capture immunoassay specificity: toxoplasma antibody detection method as a model. J Clin Microbiol 1999; 37:270-3. [PMID: 9854112 PMCID: PMC84235 DOI: 10.1128/jcm.37.1.270-273.1999] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
In the Toxoplasma gondii immunoglobulin M (IgM) capture fluorometric enzyme immunoassay used as a model, nonspecific responses due to the binding of human IgM to horseradish peroxidase (HRP) conjugates were observed despite the removal of the Fc portion of the immunoglobulin. This interaction may be mediated through the binding of human IgM to the HRP moiety of the conjugate. Addition of polymerized HRP into the reaction mixture reduced nonspecific signals in the majority of low false-positive serum reactions. Other plausible sites of interaction are conserved epitopes of mouse immunoglobulins presenting antigenic similarities with the allotopes of other species. Fragmentation of mouse antimicrobial IgG to Fab' and selection of proper conjugation procedure improved assay specificity.
Collapse
Affiliation(s)
- T Tuuminen
- Labsystems Research Laboratories, Labsystems OY, 00881 Helsinki, Finland.
| | | | | | | | | |
Collapse
|
10
|
Diagnostic des meningites a enterovirus par immunocapture IgM. Med Mal Infect 1990. [DOI: 10.1016/s0399-077x(05)80352-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
11
|
Verhofstede C, Van Renterghem L, Plum J. Evaluation of immunoblotting for the detection of Toxoplasma gondii immunoglobulin M antibodies. Eur J Clin Microbiol Infect Dis 1990; 9:835-7. [PMID: 2086220 DOI: 10.1007/bf01967387] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Immunoblot analysis was used to detect human IgM antibodies to Toxoplasma gondii in 20 patients with recent toxoplasmosis, 30 immune individuals, 30 non-immune individuals, and 24 children less then two years old. Analysis of the IgM strips revealed that specific IgM antibodies detectable after a recent Toxoplasma gondii infection react with the same antigens as the 'natural' antibodies present in the sera of immune and non-immune individuals and in the sera of young children. These data indicate that immunoblotting is not useful as a reference method for Toxoplasma gondii IgM detection, and suggest that improvement of the specificity of IgM detection will remain difficult.
Collapse
Affiliation(s)
- C Verhofstede
- Department of Medical Microbiology, University Hospital, Gent, Belgium
| | | | | |
Collapse
|
12
|
Seppänen H. Development of a highly specific and sensitive rubella immunoglobulin M antibody capture enzyme immunoassay that uses enzyme-labeled antigen. J Clin Microbiol 1990; 28:719-23. [PMID: 2185260 PMCID: PMC267783 DOI: 10.1128/jcm.28.4.719-723.1990] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
An enzyme immunoassay (EIA) for serum immunoglobulin M (IgM) antibodies to rubella virus based on enzyme labeling of viral antigen was developed. The sensitivity of the EIA for the detection of recent rubella virus infection was evaluated by using 115 rubella-IgM-antibody-positive serum specimens, which were confirmed as positive by Rubazyme M (Abbott Diagnostics). In addition, 12 individuals, 2 of whom were exposed to rubella through vaccination and 10 of whom were exposed through natural infection, were studied, and the results were compared with those obtained by indirect EIA (Rubelisa M; Electro-Nucleonics, Inc.) and immunoblotting. The sensitivity of the newly developed EIA with sera from these individuals was 100%. Serum specimens from two patients indicated that the IgM antibodies were detected by the newly developed EIA at the same time as IgM antibodies were detected by immunoblotting and before positive reactions were detected by an indirect EIA. The reference population consisted of 564 healthy blood donors and hospitalized patients (150 serum specimens). In addition, 145 serum specimens commonly giving false-positive reactions in conventional rubella IgM EIAs were studied. With these specimens, no false-positive reactions were observed. Positive IgM responses, which could not be confirmed by immunoblotting, were observed in two samples from the reference population. However, these two samples were rubella IgG positive. The overall specificity of the EIA was 99.8%.
Collapse
Affiliation(s)
- H Seppänen
- Labsystems Research Laboratories, Helsinki, Finland
| |
Collapse
|
13
|
Verhofstede C, Van Renterghem L, Plum J. Comparison of six commercial enzyme linked immunosorbent assays for detecting IgM antibodies against Toxoplasma gondii. J Clin Pathol 1989; 42:1285-90. [PMID: 2613922 PMCID: PMC502061 DOI: 10.1136/jcp.42.12.1285] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
To evaluate the usefulness of different commercial enzyme linked immunosorbent assays (ELISAs) for the detection of IgM antibodies against Toxoplasma gondii the results of six of these assays for a panel of 81 sera were compared. The following tests were selected: Toxoplasma gondii IgM ELISA (Clark Laboratories), Toxoplasma IgM EIA (Labsystems), Toxo-M EIA (Abbott), Toxonostika M (Organon), Toxo M Enzyme Immunoassay (Hybritech) and Platelia Toxo IgM (Diagnostics Pasteur). An antibody capture ELISA developed at our laboratory was used as the reference test. An IgM immunoblotting assay was also performed. Four (Toxoplasma IgM EIA, Tox-M EIA, Toxonostika M, and Platelia Toxo IgM) of the commercial IgM ELISAs gave a high sensitivity and a high specificity. Toxo-M EIA, Toxonostika M, Toxoplasma IgM EIA and the Toxo M Enzyme Immunoassay were too insensitive, and the Toxoplasma gondii IgM ELISA was both insensitive and unspecific. No remarkable differences were observed between the results of indirect or antibody capture ELISAs, and between the results of ELISAs performed with polyclonal or monoclonal antibodies.
Collapse
Affiliation(s)
- C Verhofstede
- Department of Medical Microbiology, University Hospital, Gent, Belgium
| | | | | |
Collapse
|
14
|
Sippel J, Bukhtiari N, Awan MB, Krieg R, Duncan JF, Karamat KA, Malik IA, Igbal LM, Legters L. Indirect immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assays (ELISAs) and IgM capture ELISA for detection of antibodies to lipopolysaccharide in adult typhoid fever patients in Pakistan. J Clin Microbiol 1989; 27:1298-302. [PMID: 2754002 PMCID: PMC267545 DOI: 10.1128/jcm.27.6.1298-1302.1989] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
Sera from 339 adult febrile patients in Pakistan were tested for antibodies to Salmonella typhi lipopolysaccharide by indirect immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assay (ELISA) and IgM capture ELISA. A total of 55 patients had S. typhi cultured from their blood, 20 had S. typhi cultured from their stool, 24 were blood or stool culture positive for S. paratyphi A, 41 were culture negative but clinically diagnosed as having enteric fever, 41 had gastrointestinal or urinary tract infections, 41 were clinically diagnosed as having malaria, 20 were smear-positive patients with malaria, 58 had respiratory infections, and the remaining 39 individuals were placed in a miscellaneous group who did not have Salmonella infection. The sensitivities of the indirect IgG ELISA, indirect IgM ELISA, and IgM capture ELISA determined with specimens obtained from the blood culture-positive patients with typhoid fever (positive controls) were 80, 64, and 62%, respectively. The specificities of the assays determined with sera from the patients with respiratory infections (negative controls) were 95, 95, and 97%, respectively. The percentage of smear-positive patients with malaria who were positive by these assays was lower than that in the negative control group. The percentages of individuals in the other patient categories who were positive by these tests were between those obtained with the positive and negative controls. Of the positive controls, 26 were positive by both IgM assays, 9 were IgM positive only by indirect ELISA, and 8 were IgM positive only by IgM capture ELISA. A total of 70% of the positive control patients who were tested for O agglutinins by the Widal tube agglutination assay were positive; however, 29% of the negative control patients were also positive. The indirect IgG ELISA was the single most effective test for the serodiagnosis of typhoid fever in this population.
Collapse
Affiliation(s)
- J Sippel
- Naval Medical Research Institute, Bethesda, Maryland 20814
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Evaluation d'un test E.L.I.S.A. de determination des IgM et IgG seriques dans la toxoplasmose humaine. Med Mal Infect 1987. [DOI: 10.1016/s0399-077x(87)80325-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
16
|
Gerlich WH, Uy A, Lambrecht F, Thomssen R. Cutoff levels of immunoglobulin M antibody against viral core antigen for differentiation of acute, chronic, and past hepatitis B virus infections. J Clin Microbiol 1986; 24:288-93. [PMID: 3745425 PMCID: PMC268891 DOI: 10.1128/jcm.24.2.288-293.1986] [Citation(s) in RCA: 69] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
The titer of antibody against core antigen of hepatitis B virus in the immunoglobulin M class (IgM anti-HBc) was determined by an IgM capture assay of reduced sensitivity (30 arbitrary units). The distribution of titers among 235 acute hepatitis patients who were hepatitis B surface antigen (HBsAg) positive suggested that 600 U forms a lower cutoff value for acute hepatitis B. Clinically apparent cases of acute hepatitis with high IgM anti-HBc and without HBsAg were rare (2.6%). Acute, non-B hepatitis in HBsAg carriers was more frequent (9.4%). In chronic hepatitis B, 39% of 174 biopsy-proven cases had moderate titers of 30 to 600 U, whereas healthy HBsAg carriers were rarely (4/84) positive. In mild or inapparent infections without HBsAg, titers were between 50 and 400 U. Thus, sufficiently accurate and sensitive quantitation of IgM anti-HBc allows for differentiation of acute and nonacute hepatitis B virus infection in acute hepatitis, partial differentiation between clinically symptomatic and asymptomatic chronic infections, and identification of recent subclinical infections.
Collapse
|
17
|
Herrmann JE. Enzyme-linked immunoassays for the detection of microbial antigens and their antibodies. ADVANCES IN APPLIED MICROBIOLOGY 1986; 31:271-92. [PMID: 3521211 PMCID: PMC7131335 DOI: 10.1016/s0065-2164(08)70445-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Antibodies could be labeled with enzymes for use in histochemical staining procedures by enzyme-immunoassay (EIA). The use of EIA is an extension of previously used serological tests, using enzyme-labeled antibody or antigen to determine antibody content. Direct detection of antigen by EIA represents a more dramatic departure from previous methods based on culture. Also, the method has enabled detection of infectious agents that are difficult to cultivate, such as hepatitis A virus and rotavirus, or agents that cannot be cultivated, such as hepatitis B. The use of EIA tests for detection of microbial antigens provides an alternative to culture as a means for direct identification of a specific microbial agent. It also provides a means to detect microbial agents which have not been successfully propagated. The detection of circulating antigen or detection of antigen in other body fluids by EIA is more difficult than detection of antibody because of the sensitivity required, and because of interfering substances in specimens such as feces and respiratory secretions. For this reason, very few antigen detection assays have the sensitivity and specificity required to be used as a primary diagnostic test. The number of tests that have been developed, however, is impressive and because of the possibilities for rapid, specific diagnosis, the interest in antigen detection by EIA remains high.
Collapse
|
18
|
Pretzman CI, Ralph D, Mishler L, Bodine J. Rapid separation of IgM from whole serum using spun column chromatography. J Immunol Methods 1985; 83:301-7. [PMID: 4056406 DOI: 10.1016/0022-1759(85)90251-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Spun columns were used to separate IgM from serum samples by exploiting molecular weight and size difference between IgM and other serum antibodies. Miniature gel chromatography columns were prepared in 3 ml syringe barrels. A polyacrylamide liquid chromatography gel, Bio-Gel P-200, was chosen to exclude proteins with molecular weights greater than 200,000. IgM, 900,000 MW, was excluded while IgG, 150,000 MW, was retained in the gel column. Centrifugation of the serum-loaded columns in test tubes accomplished the separation in one step by eluting a void volume equal to the sample volume from each column into a holding tube. IgM recovery in the eluent exceeded 96% of the total serum IgM in the pre-column sample. No IgG was detected in the eluent. IgM separated from La Crosse encephalitis immune human serum retained immunological activity in a viral neutralization test. Spun column chromatography is eminently suitable for diagnostic laboratories as more than 100 sera may be fractionated in one day using inexpensive materials and a low-speed centrifuge equipped with a swinging-bucket rotor.
Collapse
|