1
|
Lindenbeck MJ, Majdak P, Laback B. Effects of Monaural Temporal Electrode Asynchrony and Channel Interactions in Bilateral and Unilateral Cochlear-Implant Stimulation. Trends Hear 2024; 28:23312165241271340. [PMID: 39215517 PMCID: PMC11382250 DOI: 10.1177/23312165241271340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/04/2024] Open
Abstract
Timing cues such as interaural time differences (ITDs) and temporal pitch are pivotal for sound localization and source segregation, but their perception is degraded in cochlear-implant (CI) listeners as compared to normal-hearing listeners. In multi-electrode stimulation, intra-aural channel interactions between electrodes are assumed to be an important factor limiting access to those cues. The monaural asynchrony of stimulation timing across electrodes is assumed to mediate the amount of these interactions. This study investigated the effect of the monaural temporal electrode asynchrony (mTEA) between two electrodes, applied similarly in both ears, on ITD-based left/right discrimination sensitivity in five CI listeners, using pulse trains with 100 pulses per second and per electrode. Forward-masked spatial tuning curves were measured at both ears to find electrode separations evoking controlled degrees of across-electrode masking. For electrode separations smaller than 3 mm, results showed an effect of mTEA. Patterns were u/v-shaped, consistent with an explanation in terms of the effective pulse rate that appears to be subject to the well-known rate limitation in electric hearing. For separations larger than 7 mm, no mTEA effects were observed. A comparison to monaural rate-pitch discrimination in a separate set of listeners and in a matched setup showed no systematic differences between percepts. Overall, an important role of the mTEA in both binaural and monaural dual-electrode stimulation is consistent with a monaural pulse-rate limitation whose effect is mediated by channel interactions. Future CI stimulation strategies aiming at improved timing-cue encoding should minimize the stimulation delay between nearby electrodes that need to be stimulated successively.
Collapse
Affiliation(s)
| | - Piotr Majdak
- Acoustics Research Institute, Austrian Academy of Sciences, Vienna, Austria
| | - Bernhard Laback
- Acoustics Research Institute, Austrian Academy of Sciences, Vienna, Austria
| |
Collapse
|
2
|
Gilbert Z, Mason X, Sebastian R, Tang AM, Martin Del Campo-Vera R, Chen KH, Leonor A, Shao A, Tabarsi E, Chung R, Sundaram S, Kammen A, Cavaleri J, Gogia AS, Heck C, Nune G, Liu CY, Kellis SS, Lee B. A review of neurophysiological effects and efficiency of waveform parameters in deep brain stimulation. Clin Neurophysiol 2023; 152:93-111. [PMID: 37208270 DOI: 10.1016/j.clinph.2023.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 02/09/2023] [Accepted: 04/15/2023] [Indexed: 05/21/2023]
Abstract
Neurostimulation has diverse clinical applications and potential as a treatment for medically refractory movement disorders, epilepsy, and other neurological disorders. However, the parameters used to program electrodes-polarity, pulse width, amplitude, and frequency-and how they are adjusted have remained largely untouched since the 1970 s. This review summarizes the state-of-the-art in Deep Brain Stimulation (DBS) and highlights the need for further research to uncover the physiological mechanisms of neurostimulation. We focus on studies that reveal the potential for clinicians to use waveform parameters to selectively stimulate neural tissue for therapeutic benefit, while avoiding activating tissue associated with adverse effects. DBS uses cathodic monophasic rectangular pulses with passive recharging in clinical practice to treat neurological conditions such as Parkinson's Disease. However, research has shown that stimulation efficiency can be improved, and side effects reduced, through modulating parameters and adding novel waveform properties. These developments can prolong implantable pulse generator lifespan, reducing costs and surgery-associated risks. Waveform parameters can stimulate neurons based on axon orientation and intrinsic structural properties, providing clinicians with more precise targeting of neural pathways. These findings could expand the spectrum of diseases treatable with neuromodulation and improve patient outcomes.
Collapse
Affiliation(s)
- Zachary Gilbert
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States.
| | - Xenos Mason
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Rinu Sebastian
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Austin M Tang
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Roberto Martin Del Campo-Vera
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Kuang-Hsuan Chen
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Andrea Leonor
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Arthur Shao
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Emiliano Tabarsi
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Ryan Chung
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Shivani Sundaram
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Alexandra Kammen
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Jonathan Cavaleri
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Angad S Gogia
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States
| | - Christi Heck
- Department of Neurology, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - George Nune
- Department of Neurology, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Charles Y Liu
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; Department of Neurology, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Spencer S Kellis
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| | - Brian Lee
- Department of Neurological Surgery, Keck School of Medicine of USC, University of Southern California, Los Angeles, CA, United States; USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA, United States
| |
Collapse
|
3
|
Guérit F, Deeks JM, Arzounian D, Gransier R, Wouters J, Carlyon RP. Using Interleaved Stimulation and EEG to Measure Temporal Smoothing and Growth of the Sustained Neural Response to Cochlear-Implant Stimulation. J Assoc Res Otolaryngol 2023; 24:253-264. [PMID: 36754938 PMCID: PMC10121955 DOI: 10.1007/s10162-023-00886-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Accepted: 01/04/2023] [Indexed: 02/10/2023] Open
Abstract
Two EEG experiments measured the sustained neural response to amplitude-modulated (AM) high-rate pulse trains presented to a single cochlear-implant (CI) electrode. Stimuli consisted of two interleaved pulse trains with AM rates F1 and F2 close to 80 and 120 Hz respectively, and where F2 = 1.5F1. Following Carlyon et al. (J Assoc Res Otolaryngol, 2021), we assume that such stimuli can produce a neural distortion response (NDR) at F0 = F2-F1 Hz if temporal dependencies ("smoothing") in the auditory system are followed by one or more neural nonlinearities. In experiment 1, the rate of each pulse train was 480 pps and the gap between pulses in the F1 and F2 pulse trains ranged from 0 to 984 µs. The NDR had a roughly constant amplitude for gaps between 0 and about 200-400 µs, and decreased for longer gaps. We argue that this result is consistent with a temporal dependency, such as facilitation, operating at the level of the auditory nerve and/or with co-incidence detection by cochlear-nucleus neurons. Experiment 2 first measured the NDR for stimuli at each listener's most comfortable level ("MCL") and for F0 = 37, 40, and 43 Hz. This revealed a group delay of about 42 ms, consistent with a thalamic/cortical source. We then showed that the NDR grew steeply with stimulus amplitude and, for most listeners, decreased by more than 12 dB between MCL and 75% of the listener's dynamic range. We argue that the NDR is a potentially useful objective estimate of MCL.
Collapse
Affiliation(s)
- François Guérit
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - John M Deeks
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - Dorothée Arzounian
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England
| | - Robin Gransier
- ExpORL, Dept. of Neurosciences, KU Leuven, Leuven, Belgium
| | - Jan Wouters
- ExpORL, Dept. of Neurosciences, KU Leuven, Leuven, Belgium
| | - Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, England.
| |
Collapse
|
4
|
Müller M, Hu H, Dietz M, Beiderbeck B, Ferreiro DN, Pecka M. Temporal hyper-precision of brainstem neurons alters spatial sensitivity of binaural auditory processing with cochlear implants. Front Neurosci 2023; 16:1021541. [PMID: 36685222 PMCID: PMC9846145 DOI: 10.3389/fnins.2022.1021541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 12/08/2022] [Indexed: 01/05/2023] Open
Abstract
The ability to localize a sound source in complex environments is essential for communication and navigation. Spatial hearing relies predominantly on the comparison of differences in the arrival time of sound between the two ears, the interaural time differences (ITDs). Hearing impairments are highly detrimental to sound localization. While cochlear implants (CIs) have been successful in restoring many crucial hearing capabilities, sound localization via ITD detection with bilateral CIs remains poor. The underlying reasons are not well understood. Neuronally, ITD sensitivity is generated by coincidence detection between excitatory and inhibitory inputs from the two ears performed by specialized brainstem neurons. Due to the lack of electrophysiological brainstem recordings during CI stimulation, it is unclear to what extent the apparent deficits are caused by the binaural comparator neurons or arise already on the input level. Here, we use a bottom-up approach to compare response features between electric and acoustic stimulation in an animal model of CI hearing. Conducting extracellular single neuron recordings in gerbils, we find severe hyper-precision and moderate hyper-entrainment of both the excitatory and inhibitory brainstem inputs to the binaural comparator neurons during electrical pulse-train stimulation. This finding establishes conclusively that the binaural processing stage must cope with highly altered input statistics during CI stimulation. To estimate the consequences of these effects on ITD sensitivity, we used a computational model of the auditory brainstem. After tuning the model parameters to match its response properties to our physiological data during either stimulation type, the model predicted that ITD sensitivity to electrical pulses is maintained even for the hyper-precise inputs. However, the model exhibits severely altered spatial sensitivity during electrical stimulation compared to acoustic: while resolution of ITDs near midline was increased, more lateralized adjacent source locations became inseparable. These results directly resemble recent findings in rodent and human CI listeners. Notably, decreasing the phase-locking precision of inputs during electrical stimulation recovered a wider range of separable ITDs. Together, our findings suggest that a central problem underlying the diminished ITD sensitivity in CI users might be the temporal hyper-precision of inputs to the binaural comparator stage induced by electrical stimulation.
Collapse
Affiliation(s)
- Michaela Müller
- Graduate School of Systemic Neurosciences, Ludwig-Maximilians-Universität, Munich, Germany
| | - Hongmei Hu
- Department of Medical Physics and Acoustics, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany,Cluster of Excellence “Hearing4All”, Universität Oldenburg, Oldenburg, Germany
| | - Mathias Dietz
- Department of Medical Physics and Acoustics, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany,Cluster of Excellence “Hearing4All”, Universität Oldenburg, Oldenburg, Germany
| | - Barbara Beiderbeck
- Graduate School of Systemic Neurosciences, Ludwig-Maximilians-Universität, Munich, Germany
| | - Dardo N. Ferreiro
- Section of Neurobiology, Faculty of Biology, LMU Biocenter, Ludwig-Maximilians-Universität, Munich, Germany,Department of General Psychology and Education, Ludwig-Maximilians-Universität, Munich, Germany
| | - Michael Pecka
- Graduate School of Systemic Neurosciences, Ludwig-Maximilians-Universität, Munich, Germany,Section of Neurobiology, Faculty of Biology, LMU Biocenter, Ludwig-Maximilians-Universität, Munich, Germany,*Correspondence: Michael Pecka,
| |
Collapse
|
5
|
Comparison of response properties of the electrically stimulated auditory nerve reported in human listeners and in animal models. Hear Res 2022; 426:108643. [PMID: 36343534 PMCID: PMC9986845 DOI: 10.1016/j.heares.2022.108643] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 09/29/2022] [Accepted: 10/20/2022] [Indexed: 11/04/2022]
Abstract
Cochlear implants (CIs) provide acoustic information to implanted patients by electrically stimulating nearby auditory nerve fibers (ANFs) which then transmit the information to higher-level neural structures for further processing and interpretation. Computational models that simulate ANF responses to CI stimuli enable the exploration of the mechanisms underlying CI performance beyond the capacity of in vivo experimentation alone. However, all ANF models developed to date utilize to some extent anatomical/morphometric data, biophysical properties and/or physiological data measured in non-human animal models. This review compares response properties of the electrically stimulated auditory nerve (AN) in human listeners and different mammalian models. Properties of AN responses to single pulse stimulation, paired-pulse stimulation, and pulse-train stimulation are presented. While some AN response properties are similar between human listeners and animal models (e.g., increased AN sensitivity to single pulse stimuli with long interphase gaps), there are some significant differences. For example, the AN of most animal models is typically more sensitive to cathodic stimulation while the AN of human listeners is generally more sensitive to anodic stimulation. Additionally, there are substantial differences in the speed of recovery from neural adaptation between animal models and human listeners. Therefore, results from animal models cannot be simply translated to human listeners. Recognizing the differences in responses of the AN to electrical stimulation between humans and other mammals is an important step for creating ANF models that are more applicable to various human CI patient populations.
Collapse
|
6
|
Bissmeyer SRS, Goldsworthy RL. Combining Place and Rate of Stimulation Improves Frequency Discrimination in Cochlear Implant Users. Hear Res 2022; 424:108583. [PMID: 35930901 PMCID: PMC10849775 DOI: 10.1016/j.heares.2022.108583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 06/20/2022] [Accepted: 07/21/2022] [Indexed: 11/04/2022]
Abstract
In the auditory system, frequency is represented as tonotopic and temporal response properties of the auditory nerve. While these response properties are inextricably linked in normal hearing, cochlear implants can separately excite tonotopic location and temporal synchrony using different electrodes and stimulation rates, respectively. This separation allows for the investigation of the contributions of tonotopic and temporal cues for frequency discrimination. The present study examines frequency discrimination in adult cochlear implant users as conveyed by electrode position and stimulation rate, separately and combined. The working hypothesis is that frequency discrimination is better provided by place and rate cues combined compared to either cue alone. This hypothesis was tested in two experiments. In the first experiment, frequency discrimination needed for melodic contour identification was measured for frequencies near 100, 200, and 400 Hz using frequency allocation modeled after clinical processors. In the second experiment, frequency discrimination for pitch ranking was measured for frequencies between 100 and 1600 Hz using an experimental frequency allocation designed to provide better access to place cues. The results of both experiments indicate that frequency discrimination is better with place and rate cues combined than with either cue alone. These results clarify how signal processing for cochlear implants could better encode frequency into place and rate of electrical stimulation. Further, the results provide insight into the contributions of place and rate cues for pitch.
Collapse
Affiliation(s)
- Susan R S Bissmeyer
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, United States; Auditory Research Center, Health Research Association, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, 1640 Marengo Street Suite 326, Los Angeles, CA 90033, United States.
| | - Raymond L Goldsworthy
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, United States; Auditory Research Center, Health Research Association, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, 1640 Marengo Street Suite 326, Los Angeles, CA 90033, United States
| |
Collapse
|
7
|
He S, Skidmore J, Conroy S, Riggs WJ, Carter BL, Xie R. Neural Adaptation of the Electrically Stimulated Auditory Nerve Is Not Affected by Advanced Age in Postlingually Deafened, Middle-aged, and Elderly Adult Cochlear Implant Users. Ear Hear 2022; 43:1228-1244. [PMID: 34999595 PMCID: PMC9232840 DOI: 10.1097/aud.0000000000001184] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
OBJECTIVE This study aimed to investigate the associations between advanced age and the amount and the speed of neural adaptation of the electrically stimulated auditory nerve (AN) in postlingually deafened adult cochlear implant (CI) users. DESIGN Study participants included 26 postlingually deafened adult CI users, ranging in age between 28.7 and 84.0 years (mean: 63.8 years, SD: 14.4 years) at the time of testing. All study participants used a Cochlear Nucleus device with a full electrode array insertion in the test ear. The stimulus was a 100-ms pulse train with a pulse rate of 500, 900, 1800, or 2400 pulses per second (pps) per channel. The stimulus was presented at the maximum comfortable level measured at 2400 pps with a presentation rate of 2 Hz. Neural adaptation of the AN was evaluated using electrophysiological measures of the electrically evoked compound action potential (eCAP). The amount of neural adaptation was quantified by the adaptation index (AI) within three time windows: around 0 to 8 ms (window 1), 44 to 50 ms (window 2), and 94 to 100 ms (window 3). The speed of neural adaptation was quantified using a two-parameter power law estimation. In 23 participants, four electrodes across the electrode array were tested. In three participants, three electrodes were tested. Results measured at different electrode locations were averaged for each participant at each pulse rate to get an overall representation of neural adaptation properties of the AN across the cochlea. Linear-mixed models (LMMs) were used (1) to evaluate the effects of age at testing and pulse rate on the speed of neural adaptation and (2) to assess the effects of age at testing, pulse rate, and duration of stimulation (i.e., time window) on the amount of neural adaptation in these participants. RESULTS There was substantial variability in both the amount and the speed of neural adaptation of the AN among study participants. The amount and the speed of neural adaptation increased at higher pulse rates. In addition, larger amounts of adaptation were observed for longer durations of stimulation. There was no significant effect of age on the speed or the amount of neural adaptation. CONCLUSIONS The amount and the speed of neural adaptation of the AN are affected by both the pulse rate and the duration of stimulation, with higher pulse rates and longer durations of stimulation leading to faster and greater neural adaptation. Advanced age does not affect neural adaptation of the AN in postlingually deafened, middle-aged and elderly adult CI users.
Collapse
Affiliation(s)
- Shuman He
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Jeffrey Skidmore
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Sara Conroy
- Center for Biostatistics, Department of Bioinformatics, The Ohio State University, 1800 Cannon Drive, Columbus, OH 43210
| | - William J. Riggs
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
- Department of Audiology, Nationwide Children’s Hospital, 700 Children’s Drive, Columbus, OH 43205
| | - Brittney L. Carter
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| | - Ruili Xie
- Department of Otolaryngology – Head and Neck Surgery, The Ohio State University, 915 Olentangy River Road, Columbus, OH 43212
| |
Collapse
|
8
|
Su Y, Chung Y, Goodman DFM, Hancock KE, Delgutte B. Rate and Temporal Coding of Regular and Irregular Pulse Trains in Auditory Midbrain of Normal-Hearing and Cochlear-Implanted Rabbits. J Assoc Res Otolaryngol 2021; 22:319-347. [PMID: 33891217 DOI: 10.1007/s10162-021-00792-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 02/09/2021] [Indexed: 01/07/2023] Open
Abstract
Although pitch is closely related to temporal periodicity, stimuli with a degree of temporal irregularity can evoke a pitch sensation in human listeners. However, the neural mechanisms underlying pitch perception for irregular sounds are poorly understood. Here, we recorded responses of single units in the inferior colliculus (IC) of normal hearing (NH) rabbits to acoustic pulse trains with different amounts of random jitter in the inter-pulse intervals and compared with responses to electric pulse trains delivered through a cochlear implant (CI) in a different group of rabbits. In both NH and CI animals, many IC neurons demonstrated tuning of firing rate to the average pulse rate (APR) that was robust against temporal jitter, although jitter tended to increase the firing rates for APRs ≥ 1280 Hz. Strength and limiting frequency of spike synchronization to stimulus pulses were also comparable between periodic and irregular pulse trains, although there was a slight increase in synchronization at high APRs with CI stimulation. There were clear differences between CI and NH animals in both the range of APRs over which firing rate tuning was observed and the prevalence of synchronized responses. These results suggest that the pitches of regular and irregular pulse trains are coded differently by IC neurons depending on the APR, the degree of irregularity, and the mode of stimulation. In particular, the temporal pitch produced by periodic pulse trains lacking spectral cues may be based on a rate code rather than a temporal code at higher APRs.
Collapse
Affiliation(s)
- Yaqing Su
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, USA. .,Department of Biomedical Engineering, Boston University, Boston, MA, USA. .,Department of Basic Neurosciences, University of Geneva, Geneva, Switzerland.
| | - Yoojin Chung
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, USA.,Department of Otolaryngology, Harvard Medical School, Boston, MA, USA
| | - Dan F M Goodman
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, USA.,Department of Otolaryngology, Harvard Medical School, Boston, MA, USA.,Present Address: Department of Electrical and Electronic Engineering, Imperial College London, London, England
| | - Kenneth E Hancock
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, USA.,Department of Otolaryngology, Harvard Medical School, Boston, MA, USA
| | - Bertrand Delgutte
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, USA. .,Department of Otolaryngology, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
9
|
Carlyon RP, Guérit F, Deeks JM, Harland A, Gransier R, Wouters J, de Rijk SR, Bance M. Using Interleaved Stimulation to Measure the Size and Selectivity of the Sustained Phase-Locked Neural Response to Cochlear Implant Stimulation. J Assoc Res Otolaryngol 2021; 22:141-159. [PMID: 33492562 PMCID: PMC7943679 DOI: 10.1007/s10162-020-00783-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Accepted: 12/21/2020] [Indexed: 02/08/2023] Open
Abstract
We measured the sustained neural response to electrical stimulation by a cochlear implant (CI). To do so, we interleaved two stimuli with frequencies F1 and F2 Hz and recorded a neural distortion response (NDR) at F2-F1 Hz. We show that, because any one time point contains only the F1 or F2 stimulus, the instantaneous nonlinearities typical of electrical artefact should not produce distortion at this frequency. However, if the stimulus is smoothed, such as by charge integration at the nerve membrane, subsequent (neural) nonlinearities can produce a component at F2-F1 Hz. We stimulated a single CI electrode with interleaved sinusoids or interleaved amplitude-modulated pulse trains such that F2 = 1.5F1, and found no evidence for an NDR when F2-F1 was between 90 and 120 Hz. However, interleaved amplitude-modulated pulse trains with F2-F1~40 Hz revealed a substantial NDR with a group delay of about 45 ms, consistent with a thalamic and/or cortical response. The NDR could be measured even from recording electrodes adjacent to the implant and at the highest pulse rates (> 4000 pps) used clinically. We then measured the selectivity of this sustained response by presenting F1 and F2 to different electrodes and at different between-electrode distances. This revealed a broad tuning that, we argue, reflects the overlap between the excitation elicited by the two electrodes. Our results also provide a glimpse of the neural nonlinearity in the auditory system, unaffected by the biomechanical cochlear nonlinearities that accompany acoustic stimulation. Several potential clinical applications of our findings are discussed.
Collapse
Affiliation(s)
- Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, 15 Chaucer Rd, Cambridge, CB2 7EF, England.
| | - François Guérit
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, 15 Chaucer Rd, Cambridge, CB2 7EF, England
| | - John M Deeks
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, 15 Chaucer Rd, Cambridge, CB2 7EF, England
| | - Andrew Harland
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, 15 Chaucer Rd, Cambridge, CB2 7EF, England
| | - Robin Gransier
- Dept. of Neurosciences, ExpORL, KU Leuven, Herestraat 49 box 721, 3000, Leuven, Belgium
| | - Jan Wouters
- Dept. of Neurosciences, ExpORL, KU Leuven, Herestraat 49 box 721, 3000, Leuven, Belgium
| | - Simone R de Rijk
- Cambridge Hearing Group, Dept. Clinical Neurosciences, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, England
| | - Manohar Bance
- Cambridge Hearing Group, Dept. Clinical Neurosciences, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, England
| |
Collapse
|
10
|
Bissmeyer SRS, Hossain S, Goldsworthy RL. Perceptual learning of pitch provided by cochlear implant stimulation rate. PLoS One 2020; 15:e0242842. [PMID: 33270735 PMCID: PMC7714175 DOI: 10.1371/journal.pone.0242842] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Accepted: 11/10/2020] [Indexed: 11/19/2022] Open
Abstract
Cochlear implant users hear pitch evoked by stimulation rate, but discrimination diminishes for rates above 300 Hz. This upper limit on rate pitch is surprising given the remarkable and specialized ability of the auditory nerve to respond synchronously to stimulation rates at least as high as 3 kHz and arguably as high as 10 kHz. Sensitivity to stimulation rate as a pitch cue varies widely across cochlear implant users and can be improved with training. The present study examines individual differences and perceptual learning of stimulation rate as a cue for pitch ranking. Adult cochlear implant users participated in electrode psychophysics that involved testing once per week for three weeks. Stimulation pulse rate discrimination was measured in bipolar and monopolar configurations for apical and basal electrodes. Base stimulation rates between 100 and 800 Hz were examined. Individual differences were quantified using psychophysically derived metrics of spatial tuning and temporal integration. This study examined distribution of measures across subjects, predictive power of psychophysically derived metrics of spatial tuning and temporal integration, and the effect of training on rate discrimination thresholds. Psychophysical metrics of spatial tuning and temporal integration were not predictive of stimulation rate discrimination, but discrimination thresholds improved at lower frequencies with training. Since most clinical devices do not use variable stimulation rates, it is unknown to what extent recipients may learn to use stimulation rate cues if provided in a clear and consistent manner.
Collapse
Affiliation(s)
- Susan R. S. Bissmeyer
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, United States of America
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, California, United States of America
| | - Shaikat Hossain
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, California, United States of America
| | - Raymond L. Goldsworthy
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, United States of America
- Auditory Research Center, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, California, United States of America
| |
Collapse
|
11
|
Mussoi BSS, Brown CJ. Age-Related Changes in Temporal Resolution Revisited: Electrophysiological and Behavioral Findings From Cochlear Implant Users. Ear Hear 2020; 40:1328-1344. [PMID: 31033701 PMCID: PMC6814519 DOI: 10.1097/aud.0000000000000732] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
OBJECTIVES The mechanisms underlying age-related changes in speech perception are still unclear, most likely multifactorial and often can be difficult to parse out from the effects of hearing loss. Age-related changes in temporal resolution (i.e., the ability to track rapid changes in sounds) have long been associated with speech perception declines exhibited by many older individuals. The goals of this study were as follows: (1) to assess age-related changes in temporal resolution in cochlear implant (CI) users, and (2) to examine the impact of changes in temporal resolution and cognition on the perception of speech in noise. In this population, it is possible to bypass the cochlea and stimulate the auditory nerve directly in a noninvasive way. Additionally, CI technology allows for manipulation of the temporal properties of a signal without changing its spectrum. DESIGN Twenty postlingually deafened Nucleus CI users took part in this study. They were divided into groups of younger (18 to 40 years) and older (68 to 82 years) participants. A cross-sectional study design was used. The speech processor was bypassed and a mid-array electrode was used for stimulation. We compared peripheral and central physiologic measures of temporal resolution with perceptual measures obtained using similar stimuli. Peripherally, temporal resolution was assessed with measures of the rate of recovery of the electrically evoked compound action potential (ECAP), evoked using a single pulse and a pulse train as maskers. The acoustic change complex (ACC) to gaps in pulse trains was used to assess temporal resolution more centrally. Psychophysical gap detection thresholds were also obtained. Cognitive assessment included two tests of processing speed (Symbol Search and Coding) and one test of working memory (Digit Span Test). Speech perception was tested in the presence of background noise (QuickSIN test). A correlational design was used to explore the relationship between temporal resolution, cognition, and speech perception. RESULTS The only metric that showed significant age effects in temporal processing was the ECAP recovery function recorded using pulse train maskers. Younger participants were found to have faster rates of neural recovery following presentation of pulse trains than older participants. Age was not found to have a significant effect on speech perception. When results from both groups were combined, digit span was the only measure significantly correlated with speech perception performance. CONCLUSIONS In this sample of CI users, few effects of advancing age on temporal resolution were evident. While this finding would be consistent with a general lack of aging effects on temporal resolution, it is also possible that aging effects are influenced by processing peripheral to the auditory nerve, which is bypassed by the CI. However, it is known that cross-fiber neural synchrony is improved with electrical (as opposed to acoustic) stimulation. This change in neural synchrony may, in turn, make temporal cues more robust/perceptible to all CI users. Future studies involving larger sample sizes should be conducted to confirm these findings. Results of this study also add to the growing body of literature that suggests that working memory is important for the perception of degraded speech.
Collapse
Affiliation(s)
- Bruna S. S. Mussoi
- Kent State University, Speech Pathology and Audiology Program, Kent, Ohio, USA
| | - Carolyn J. Brown
- University of Iowa, Department of Communication Sciences and Disorders / Department of Otolaryngology – Head and Neck Surgery, Iowa City, Iowa, USA
| |
Collapse
|
12
|
Stupak N, Padilla M, Morse RP, Landsberger DM. Perceptual Differences Between Low-Frequency Analog and Pulsatile Stimulation as Shown by Single- and Multidimensional Scaling. Trends Hear 2019; 22:2331216518807535. [PMID: 30378468 PMCID: PMC6236864 DOI: 10.1177/2331216518807535] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Cochlear-implant users who have experienced both analog and pulsatile sound
coding strategies often have strong preferences for the sound quality of one
over the other. This suggests that analog and pulsatile stimulation may provide
different information or sound quality to an implant listener. It has been well
documented that many implant listeners both prefer and perform better with
multichannel analog than multichannel pulsatile strategies, although the reasons
for these differences remain unknown. Here, we examine the perceptual
differences between analog and pulsatile stimulation on a single electrode. A
multidimensional scaling task, analyzed across two dimensions, suggested that
pulsatile stimulation was perceived to be considerably different from analog
stimulation. Two associated tasks using single-dimensional scaling showed that
analog stimulation was perceived to be less Clean on average than pulsatile
stimulation and that the perceptual differences were not related to pitch. In a
follow-up experiment, it was determined that the perceptual differences between
analog and pulsatile stimulation were not dependent on the interpulse gap
present in pulsatile stimulation. Although the results suggest that there is a
large perceptual difference between analog and pulsatile stimulation, further
work is needed to determine the nature of these differences.
Collapse
Affiliation(s)
- Natalia Stupak
- 1 Department of Otolaryngology, New York University School of Medicine, NY, USA
| | - Monica Padilla
- 1 Department of Otolaryngology, New York University School of Medicine, NY, USA.,2 USC Tina and Rick Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Robert P Morse
- 3 School of Engineering, University of Warwick, Coventry, UK
| | - David M Landsberger
- 1 Department of Otolaryngology, New York University School of Medicine, NY, USA
| |
Collapse
|
13
|
Shepherd RK, Villalobos J, Burns O, Nayagam DAX. The development of neural stimulators: a review of preclinical safety and efficacy studies. J Neural Eng 2018; 15:041004. [PMID: 29756600 PMCID: PMC6049833 DOI: 10.1088/1741-2552/aac43c] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Given the rapid expansion of the field of neural stimulation and the rigorous regulatory approval requirements required before these devices can be applied clinically, it is important that there is clarity around conducting preclinical safety and efficacy studies required for the development of this technology. APPROACH The present review examines basic design principles associated with the development of a safe neural stimulator and describes the suite of preclinical safety studies that need to be considered when taking a device to clinical trial. MAIN RESULTS Neural stimulators are active implantable devices that provide therapeutic intervention, sensory feedback or improved motor control via electrical stimulation of neural or neuro-muscular tissue in response to trauma or disease. Because of their complexity, regulatory bodies classify these devices in the highest risk category (Class III), and they are therefore required to go through a rigorous regulatory approval process before progressing to market. The successful development of these devices is achieved through close collaboration across disciplines including engineers, scientists and a surgical/clinical team, and the adherence to clear design principles. Preclinical studies form one of several key components in the development pathway from concept to product release of neural stimulators. Importantly, these studies provide iterative feedback in order to optimise the final design of the device. Key components of any preclinical evaluation include: in vitro studies that are focussed on device reliability and include accelerated testing under highly controlled environments; in vivo studies using animal models of the disease or injury in order to assess efficacy and, given an appropriate animal model, the safety of the technology under both passive and electrically active conditions; and human cadaver and ex vivo studies designed to ensure the device's form factor conforms to human anatomy, to optimise the surgical approach and to develop any specialist surgical tooling required. SIGNIFICANCE The pipeline from concept to commercialisation of these devices is long and expensive; careful attention to both device design and its preclinical evaluation will have significant impact on the duration and cost associated with taking a device through to commercialisation. Carefully controlled in vitro and in vivo studies together with ex vivo and human cadaver trials are key components of a thorough preclinical evaluation of any new neural stimulator.
Collapse
Affiliation(s)
- Robert K Shepherd
- Bionics Institute, East Melbourne, Australia. Medical Bionics Department, University of Melbourne, Melbourne, Australia
| | | | | | | |
Collapse
|
14
|
Relationship Between Peripheral and Psychophysical Measures of Amplitude Modulation Detection in Cochlear Implant Users. Ear Hear 2018; 38:e268-e284. [PMID: 28207576 DOI: 10.1097/aud.0000000000000417] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE This study investigates the relationship between electrophysiological and psychophysical measures of amplitude modulation (AM) detection. Prior studies have reported both measures of AM detection recorded separately from cochlear implant (CI) users and acutely deafened animals, but no study has made both measures in the same CI users. Animal studies suggest a progressive loss of high-frequency encoding as one ascends the auditory pathway from the auditory nerve to the cortex. Because the CI speech processor uses the envelope of an ongoing acoustic signal to modulate pulse trains that are subsequently delivered to the intracochlear electrodes, it is of interest to explore auditory nerve responses to modulated stimuli. In addition, psychophysical AM detection abilities have been correlated with speech perception outcomes. Thus, the goal was to explore how the auditory nerve responds to AM stimuli and to relate those physiologic measures to perception. DESIGN Eight patients using Cochlear Ltd. Implants participated in this study. Electrically evoked compound action potentials (ECAPs) were recorded using a 4000 pps pulse train that was sinusoidally amplitude modulated at 125, 250, 500, and 1000 Hz rates. Responses were measured for each pulse over at least one modulation cycle for an apical, medial, and basal electrode. Psychophysical modulation detection thresholds (MDTs) were also measured via a three-alternative forced choice, two-down, one-up adaptive procedure using the same modulation frequencies and electrodes. RESULTS ECAPs were recorded from individual pulses in the AM pulse train. ECAP amplitudes varied sinusoidally, reflecting the sinusoidal variation in the stimulus. A modulated response amplitude (MRA) metric was calculated as the difference in the maximal and minimum ECAP amplitudes over the modulation cycles. MRA increased as modulation frequency increased, with no apparent cutoff (up to 1000 Hz). In contrast, MDTs increased as the modulation frequency increased. This trend is inconsistent with the physiologic measures. For a fixed modulation frequency, correlations were observed between MDTs and MRAs; this trend was evident at all frequencies except 1000 Hz (although only statistically significant for 250 and 500 Hz AM rates), possibly an indication of central limitations in processing of high modulation frequencies. Finally, peripheral responses were larger and psychophysical thresholds were lower in the apical electrodes relative to basal and medial electrodes, which may reflect better cochlear health and neural survival evidenced by lower preoperative low-frequency audiometric thresholds and steeper growth of neural responses in ECAP amplitude growth functions for apical electrodes. CONCLUSIONS Robust ECAPs were recorded for all modulation frequencies tested. ECAP amplitudes varied sinusoidally, reflecting the periodicity of the modulated stimuli. MRAs increased as the modulation frequency increased, a trend we attribute to neural adaptation. For low modulation frequencies, there are multiple current steps between the peak and valley of the modulation cycle, which means successive stimuli are more similar to one another and neural responses are more likely to adapt. Higher MRAs were correlated with lower psychophysical thresholds at low modulation frequencies but not at 1000 Hz, implying a central limitation to processing of modulated stimuli.
Collapse
|
15
|
Badenhorst W, Hanekom T, Hanekom JJ. Analysis of a purely conductance-based stochastic nerve fibre model as applied to compound models of populations of human auditory nerve fibres used in cochlear implant simulations. BIOLOGICAL CYBERNETICS 2017; 111:439-458. [PMID: 29063191 DOI: 10.1007/s00422-017-0736-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2017] [Accepted: 10/07/2017] [Indexed: 06/07/2023]
Abstract
The study presents the application of a purely conductance-based stochastic nerve fibre model to human auditory nerve fibres within finite element volume conduction models of a semi-generic head and user-specific cochleae. The stochastic, threshold and temporal characteristics of the human model are compared and successfully validated against physiological feline results with the application of a mono-polar, bi-phasic, cathodic first stimulus. Stochastic characteristics validated include: (i) the log(Relative Spread) versus log(fibre diameter) distribution for the discharge probability versus stimulus intensity plots and (ii) the required exponential membrane noise versus transmembrane voltage distribution. Intra-user, and to a lesser degree inter-user, comparisons are made with respect to threshold and dynamic range at short and long pulse widths for full versus degenerate single fibres as well as for populations of degenerate fibres of a single user having distributed and aligned somas with varying and equal diameters. Temporal characteristics validated through application of different stimulus pulse rates and different stimulus intensities include: (i) discharge rate, latency and latency standard deviation versus stimulus intensity, (ii) period histograms and (iii) interspike interval histograms. Although the stochastic population model does not reduce the modelled single deterministic fibre threshold, the simulated stochastic and temporal characteristics show that it could be used in future studies to model user-specific temporally encoded information, which influences the speech perception of CI users.
Collapse
Affiliation(s)
- Werner Badenhorst
- Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Lynnwood Road, Pretoria, 0002, South Africa.
| | - Tania Hanekom
- Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Lynnwood Road, Pretoria, 0002, South Africa
| | - Johan J Hanekom
- Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Lynnwood Road, Pretoria, 0002, South Africa
| |
Collapse
|
16
|
Hancock KE, Chung Y, McKinney MF, Delgutte B. Temporal Envelope Coding by Inferior Colliculus Neurons with Cochlear Implant Stimulation. J Assoc Res Otolaryngol 2017; 18:771-788. [PMID: 28717877 DOI: 10.1007/s10162-017-0638-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2016] [Accepted: 07/07/2017] [Indexed: 11/26/2022] Open
Abstract
Modulations in temporal envelopes are a ubiquitous property of natural sounds and are especially important for hearing with cochlear implants (CIs) because these devices typically discard temporal fine structure information. With few exceptions, neural temporal envelope processing has been studied in both normal hearing (NH) and CI animals using only pure sinusoidal amplitude modulation (SAM) which poorly represents the diversity of envelope shapes contained in natural sounds because it confounds repetition rate and the width of each modulation cycle. Here, we used stimuli that allow independent manipulation of the two parameters to characterize envelope processing by inferior colliculus (IC) neurons in barbiturate-anesthetized cats with CIs. Specifically, the stimuli were amplitude modulated, high rate pulse trains, where the envelope waveform interleaved single cycles ("bursts") of a sinusoid with silent intervals. We found that IC neurons vary widely with respect to the envelope parameters that maximize their firing rates. In general, pure SAM was a relatively ineffective stimulus. The majority of neurons (60 %) preferred a combination of short bursts and low repetition rates (long silent intervals). Others preferred low repetition rates with minimal dependence on envelope width (17 %), while the remainder responded most strongly to brief bursts with lesser sensitivity to repetition rate (23 %). A simple phenomenological model suggests that a combination of inhibitory and intrinsic cellular mechanisms suffices to account for the wide variation in optimal envelope shapes. In contrast to the strong dependence of firing rate on envelope shape, neurons tended to phase lock precisely to the envelope regardless of shape. Most neurons tended to fire specifically near the peak of the modulation cycle, with little phase dispersion within or across neurons. Such consistently precise timing degrades envelope coding compared to NH processing of real-world sounds, because it effectively eliminates spike timing as a cue to envelope shape.
Collapse
Affiliation(s)
- Kenneth E Hancock
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, 02114, USA.
- Department of Otolaryngology, Harvard Medical School, Boston, MA, 02115, USA.
| | - Yoojin Chung
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, 02114, USA
- Department of Otolaryngology, Harvard Medical School, Boston, MA, 02115, USA
| | | | - Bertrand Delgutte
- Eaton-Peabody Laboratories, Massachusetts Eye and Ear, Boston, MA, 02114, USA
- Department of Otolaryngology, Harvard Medical School, Boston, MA, 02115, USA
| |
Collapse
|
17
|
A Test of the Stereausis Hypothesis for Sound Localization in Mammals. J Neurosci 2017; 37:7278-7289. [PMID: 28659280 DOI: 10.1523/jneurosci.0233-17.2017] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Revised: 05/20/2017] [Accepted: 05/25/2017] [Indexed: 11/21/2022] Open
Abstract
The relative arrival times of sounds at both ears constitute an important cue for localization of low-frequency sounds in the horizontal plane. The binaural neurons of the medial superior olive (MSO) act as coincidence detectors that fire when inputs from both ears arrive near simultaneously. Each principal neuron in the MSO is tuned to its own best interaural time difference (ITD), indicating the presence of an internal delay, a difference in the travel times from either ear to the MSO. According to the stereausis hypothesis, differences in wave propagation along the cochlea could provide the delays necessary for coincidence detection if the ipsilateral and contralateral inputs originated from different cochlear positions, with different frequency tuning. We therefore investigated the relation between interaural mismatches in frequency tuning and ITD tuning during in vivo loose-patch (juxtacellular) recordings from principal neurons of the MSO of anesthetized female gerbils. Cochlear delays can be bypassed by directly stimulating the auditory nerve; in agreement with the stereausis hypothesis, tuning for timing differences during bilateral electrical stimulation of the round windows differed markedly from ITD tuning in the same cells. Moreover, some neurons showed a frequency tuning mismatch that was sufficiently large to have a potential impact on ITD tuning. However, we did not find a correlation between frequency tuning mismatches and best ITDs. Our data thus suggest that axonal delays dominate ITD tuning.SIGNIFICANCE STATEMENT Neurons in the medial superior olive (MSO) play a unique role in sound localization because of their ability to compare the relative arrival time of low-frequency sounds at both ears. They fire maximally when the difference in sound arrival time exactly compensates for the internal delay: the difference in travel time from either ear to the MSO neuron. We tested whether differences in cochlear delay systematically contribute to the total travel time by comparing for individual MSO neurons the best difference in arrival times, as predicted from the frequency tuning for either ear, and the actual best difference. No systematic relation was observed, emphasizing the dominant contribution of axonal delays to the internal delay.
Collapse
|
18
|
Zheng Y, Escabí M, Litovsky RY. Spectro-temporal cues enhance modulation sensitivity in cochlear implant users. Hear Res 2017; 351:45-54. [PMID: 28601530 DOI: 10.1016/j.heares.2017.05.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2017] [Revised: 05/12/2017] [Accepted: 05/23/2017] [Indexed: 10/19/2022]
Abstract
Although speech understanding is highly variable amongst cochlear implants (CIs) subjects, the remarkably high speech recognition performance of many CI users is unexpected and not well understood. Numerous factors, including neural health and degradation of the spectral information in the speech signal of CIs, likely contribute to speech understanding. We studied the ability to use spectro-temporal modulations, which may be critical for speech understanding and discrimination, and hypothesize that CI users adopt a different perceptual strategy than normal-hearing (NH) individuals, whereby they rely more heavily on joint spectro-temporal cues to enhance detection of auditory cues. Modulation detection sensitivity was studied in CI users and NH subjects using broadband "ripple" stimuli that were modulated spectrally, temporally, or jointly, i.e., spectro-temporally. The spectro-temporal modulation transfer functions of CI users and NH subjects was decomposed into spectral and temporal dimensions and compared to those subjects' spectral-only and temporal-only modulation transfer functions. In CI users, the joint spectro-temporal sensitivity was better than that predicted by spectral-only and temporal-only sensitivity, indicating a heightened spectro-temporal sensitivity. Such an enhancement through the combined integration of spectral and temporal cues was not observed in NH subjects. The unique use of spectro-temporal cues by CI patients can yield benefits for use of cues that are important for speech understanding. This finding has implications for developing sound processing strategies that may rely on joint spectro-temporal modulations to improve speech comprehension of CI users, and the findings of this study may be valuable for developing clinical assessment tools to optimize CI processor performance.
Collapse
Affiliation(s)
- Yi Zheng
- Waisman Center, University of Wisconsin Madison, 1500 Highland Avenue, Madison, WI, 53705, USA
| | - Monty Escabí
- Biomedical Engineering, Electrical and Computer Engineering, University of Connecticut, 371 Fairfield Rd., U1157, Storrs, CT, 06269, USA
| | - Ruth Y Litovsky
- Waisman Center, University of Wisconsin Madison, 1500 Highland Avenue, Madison, WI, 53705, USA.
| |
Collapse
|
19
|
van Gendt M, Briaire J, Kalkman R, Frijns J. A fast, stochastic, and adaptive model of auditory nerve responses to cochlear implant stimulation. Hear Res 2016; 341:130-143. [DOI: 10.1016/j.heares.2016.08.011] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Revised: 08/18/2016] [Accepted: 08/21/2016] [Indexed: 11/15/2022]
|
20
|
O'Brien GE, Rubinstein JT. The development of biophysical models of the electrically stimulated auditory nerve: Single-node and cable models. NETWORK (BRISTOL, ENGLAND) 2016; 27:135-156. [PMID: 27070730 DOI: 10.3109/0954898x.2016.1162338] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
In the last few decades, biophysical models have emerged as a prominent tool in the study and improvement of cochlear implants, a neural prosthetic that restores a degree of sound perception to the profoundly deaf. Owing to the spatial phenomena associated with extracellular stimulation, these models have evolved to a relatively high degree of morphological and physiological detail: single-node models in the tradition of Hodgkin-Huxley are paired with cable descriptions of the auditory nerve fiber. No singular model has emerged as a frontrunner to the field; rather, parameter sets deriving from the channel kinetics and morphologies of numerous organisms (mammalian and otherwise) are combined and tuned to foster strong agreement with response properties observed in vivo, such as refractoriness, summation, and strength-duration relationships. Recently, biophysical models of the electrically stimulated auditory nerve have begun to incorporate adaptation and stochastic mechanisms, in order to better realize the goal of predicting realistic neural responses to a wide array of stimuli.
Collapse
Affiliation(s)
- Gabrielle E O'Brien
- a Department of Otolaryngology, V.M. Bloedel Hearing Research Center , University of Washington , Seattle , Washington , USA
| | - Jay T Rubinstein
- a Department of Otolaryngology, V.M. Bloedel Hearing Research Center , University of Washington , Seattle , Washington , USA
| |
Collapse
|
21
|
Mulders WHAM, Spencer TC, Robertson D. Effects of pulsatile electrical stimulation of the round window on central hyperactivity after cochlear trauma in guinea pig. Hear Res 2016; 335:128-137. [PMID: 26970475 DOI: 10.1016/j.heares.2016.03.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Revised: 02/09/2016] [Accepted: 03/03/2016] [Indexed: 11/17/2022]
Abstract
Partial hearing loss induced by acoustic trauma has been shown in animal models to result in an increased spontaneous firing rate in central auditory structures. This so-called hyperactivity has been suggested to be involved in the generation of tinnitus, a phantom auditory sensation. Although there is no universal cure for tinnitus, electrical stimulation of the cochlea, as achieved by a cochlear implant, can result in significant reduction of the tinnitus percept. However, the mechanism by which this tinnitus suppression occurs is as yet unknown and furthermore cochlear implantation may not be an optimal treatment option for tinnitus sufferers who are not profoundly deaf. A better understanding of the mechanism of tinnitus suppression by electrical stimulation of the cochlea, may lead to the development of more specialised devices for those for whom a cochlear implant is not appropriate. This study aimed to investigate the effects of electrical stimulation in the form of brief biphasic shocks delivered to the round window of the cochlea on the spontaneous firing rates of hyperactive inferior colliculus neurons following acoustic trauma in guinea pigs. Effects during the stimulation itself included both inhibition and excitation but spontaneous firing was suppressed for up to hundreds of ms after the cessation of the shock train in all sampled hyperactive neurons. Pharmacological block of olivocochlear efferent action on outer hair cells did not eliminate the prolonged suppression observed in inferior colliculus neurons, and it is therefore likely that activation of the afferent pathways is responsible for the central effects observed.
Collapse
Affiliation(s)
- W H A M Mulders
- The Auditory Laboratory, School of Anatomy, Physiology and Human Biology, The University of Western Australia, 35 Stirling Highway, Crawley WA 6009, Australia.
| | - T C Spencer
- The Auditory Laboratory, School of Anatomy, Physiology and Human Biology, The University of Western Australia, 35 Stirling Highway, Crawley WA 6009, Australia
| | - D Robertson
- The Auditory Laboratory, School of Anatomy, Physiology and Human Biology, The University of Western Australia, 35 Stirling Highway, Crawley WA 6009, Australia
| |
Collapse
|
22
|
Yang H, Woo J. Effect of axon diameter and electrode position on responses to sinusoidally amplitude-modulated electric pulse-train stimuli. Biomed Eng Lett 2015. [DOI: 10.1007/s13534-015-0181-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
23
|
Pham CQ, Bremen P, Shen W, Yang SM, Middlebrooks JC, Zeng FG, Mc Laughlin M. Central Auditory Processing of Temporal and Spectral-Variance Cues in Cochlear Implant Listeners. PLoS One 2015; 10:e0132423. [PMID: 26176553 PMCID: PMC4503639 DOI: 10.1371/journal.pone.0132423] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2014] [Accepted: 06/13/2015] [Indexed: 11/25/2022] Open
Abstract
Cochlear implant (CI) listeners have difficulty understanding speech in complex listening environments. This deficit is thought to be largely due to peripheral encoding problems arising from current spread, which results in wide peripheral filters. In normal hearing (NH) listeners, central processing contributes to segregation of speech from competing sounds. We tested the hypothesis that basic central processing abilities are retained in post-lingually deaf CI listeners, but processing is hampered by degraded input from the periphery. In eight CI listeners, we measured auditory nerve compound action potentials to characterize peripheral filters. Then, we measured psychophysical detection thresholds in the presence of multi-electrode maskers placed either inside (peripheral masking) or outside (central masking) the peripheral filter. This was intended to distinguish peripheral from central contributions to signal detection. Introduction of temporal asynchrony between the signal and masker improved signal detection in both peripheral and central masking conditions for all CI listeners. Randomly varying components of the masker created spectral-variance cues, which seemed to benefit only two out of eight CI listeners. Contrastingly, the spectral-variance cues improved signal detection in all five NH listeners who listened to our CI simulation. Together these results indicate that widened peripheral filters significantly hamper central processing of spectral-variance cues but not of temporal cues in post-lingually deaf CI listeners. As indicated by two CI listeners in our study, however, post-lingually deaf CI listeners may retain some central processing abilities similar to NH listeners.
Collapse
Affiliation(s)
- Carol Q. Pham
- Center for Hearing Research, University of California Irvine, Irvine, California, United States of America
- Department of Anatomy and Neurobiology, University of California Irvine, Irvine, California, United States of America
- * E-mail:
| | - Peter Bremen
- Center for Hearing Research, University of California Irvine, Irvine, California, United States of America
- Department of Otolaryngology- Head and Neck Surgery, University of California Irvine, Irvine, California, United States of America
| | - Weidong Shen
- Institute of Otolaryngology, Chinese PLA Genera Hospital, Beijing, China
| | - Shi-Ming Yang
- Institute of Otolaryngology, Chinese PLA Genera Hospital, Beijing, China
| | - John C. Middlebrooks
- Center for Hearing Research, University of California Irvine, Irvine, California, United States of America
- Department of Otolaryngology- Head and Neck Surgery, University of California Irvine, Irvine, California, United States of America
- Department of Neurobiology and Behavior, University of California Irvine, Irvine, California, United States of America
- Department of Biomedical Engineering, University of California Irvine, Irvine, California, United States of America
- Department of Cognitive Sciences, University of California Irvine, Irvine, California, United States of America
| | - Fan-Gang Zeng
- Center for Hearing Research, University of California Irvine, Irvine, California, United States of America
- Department of Anatomy and Neurobiology, University of California Irvine, Irvine, California, United States of America
- Department of Otolaryngology- Head and Neck Surgery, University of California Irvine, Irvine, California, United States of America
- Department of Biomedical Engineering, University of California Irvine, Irvine, California, United States of America
- Department of Cognitive Sciences, University of California Irvine, Irvine, California, United States of America
| | - Myles Mc Laughlin
- Center for Hearing Research, University of California Irvine, Irvine, California, United States of America
- Department of Otolaryngology- Head and Neck Surgery, University of California Irvine, Irvine, California, United States of America
| |
Collapse
|
24
|
Perception and coding of interaural time differences with bilateral cochlear implants. Hear Res 2015; 322:138-50. [DOI: 10.1016/j.heares.2014.10.004] [Citation(s) in RCA: 82] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Revised: 10/01/2014] [Accepted: 10/07/2014] [Indexed: 11/21/2022]
|
25
|
Tillein J, Hartmann R, Kral A. Electric-acoustic interactions in the hearing cochlea: Single fiber recordings. Hear Res 2015; 322:112-26. [DOI: 10.1016/j.heares.2014.09.011] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2014] [Revised: 08/30/2014] [Accepted: 09/22/2014] [Indexed: 10/24/2022]
|
26
|
Shannon RV. Auditory implant research at the House Ear Institute 1989-2013. Hear Res 2015; 322:57-66. [PMID: 25449009 PMCID: PMC4380593 DOI: 10.1016/j.heares.2014.11.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Revised: 11/04/2014] [Accepted: 11/07/2014] [Indexed: 11/29/2022]
Abstract
The House Ear Institute (HEI) had a long and distinguished history of auditory implant innovation and development. Early clinical innovations include being one of the first cochlear implant (CI) centers, being the first center to implant a child with a cochlear implant in the US, developing the auditory brainstem implant, and developing multiple surgical approaches and tools for Otology. This paper reviews the second stage of auditory implant research at House - in-depth basic research on perceptual capabilities and signal processing for both cochlear implants and auditory brainstem implants. Psychophysical studies characterized the loudness and temporal perceptual properties of electrical stimulation as a function of electrical parameters. Speech studies with the noise-band vocoder showed that only four bands of tonotopically arrayed information were sufficient for speech recognition, and that most implant users were receiving the equivalent of 8-10 bands of information. The noise-band vocoder allowed us to evaluate the effects of the manipulation of the number of bands, the alignment of the bands with the original tonotopic map, and distortions in the tonotopic mapping, including holes in the neural representation. Stimulation pulse rate was shown to have only a small effect on speech recognition. Electric fields were manipulated in position and sharpness, showing the potential benefit of improved tonotopic selectivity. Auditory training shows great promise for improving speech recognition for all patients. And the Auditory Brainstem Implant was developed and improved and its application expanded to new populations. Overall, the last 25 years of research at HEI helped increase the basic scientific understanding of electrical stimulation of hearing and contributed to the improved outcomes for patients with the CI and ABI devices. This article is part of a Special Issue entitled .
Collapse
Affiliation(s)
- Robert V Shannon
- Department of Otolaryngology, University of Southern California, Keck School of Medicine of USC, 806 W. Adams Blvd, Los Angeles, CA 90007-2505, USA.
| |
Collapse
|
27
|
Rattay F, Potrusil T, Wenger C, Wise AK, Glueckert R, Schrott-Fischer A. Impact of morphometry, myelinization and synaptic current strength on spike conduction in human and cat spiral ganglion neurons. PLoS One 2013; 8:e79256. [PMID: 24260179 PMCID: PMC3832640 DOI: 10.1371/journal.pone.0079256] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2012] [Accepted: 09/20/2013] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND Our knowledge about the neural code in the auditory nerve is based to a large extent on experiments on cats. Several anatomical differences between auditory neurons in human and cat are expected to lead to functional differences in speed and safety of spike conduction. METHODOLOGY/PRINCIPAL FINDINGS Confocal microscopy was used to systematically evaluate peripheral and central process diameters, commonness of myelination and morphology of spiral ganglion neurons (SGNs) along the cochlea of three human and three cats. Based on these morphometric data, model analysis reveales that spike conduction in SGNs is characterized by four phases: a postsynaptic delay, constant velocity in the peripheral process, a presomatic delay and constant velocity in the central process. The majority of SGNs are type I, connecting the inner hair cells with the brainstem. In contrast to those of humans, type I neurons of the cat are entirely myelinated. Biophysical model evaluation showed delayed and weak spikes in the human soma region as a consequence of a lack of myelin. The simulated spike conduction times are in accordance with normal interwave latencies from auditory brainstem response recordings from man and cat. Simulated 400 pA postsynaptic currents from inner hair cell ribbon synapses were 15 times above threshold. They enforced quick and synchronous spiking. Both of these properties were not present in type II cells as they receive fewer and much weaker (∼26 pA) synaptic stimuli. CONCLUSIONS/SIGNIFICANCE Wasting synaptic energy boosts spike initiation, which guarantees the rapid transmission of temporal fine structure of auditory signals. However, a lack of myelin in the soma regions of human type I neurons causes a large delay in spike conduction in comparison with cat neurons. The absent myelin, in combination with a longer peripheral process, causes quantitative differences of temporal parameters in the electrically stimulated human cochlea compared to the cat cochlea.
Collapse
Affiliation(s)
- Frank Rattay
- Institute for Analysis and Scientific Computing, Vienna University of Technology, Vienna, Austria
| | - Thomas Potrusil
- Department of Otorhinolaryngology, Innsbruck Medical University, Innsbruck, Austria
- Faculty of Informatics, Vienna University of Technology, Vienna, Austria
| | - Cornelia Wenger
- Institute of Biophysics and Biomedical Engeneering, Faculty of Science, University of Lisbon, Lisbon, Portugal
| | | | - Rudolf Glueckert
- Department of Otorhinolaryngology, Innsbruck Medical University, Innsbruck, Austria
- University Clinics Innsbruck, Tiroler Landeskrankenanstalten, Innsbruck, Austria
| | | |
Collapse
|
28
|
Malherbe TK, Hanekom T, Hanekom JJ. Can subject-specific single-fibre electrically evoked auditory brainstem response data be predicted from a model? Med Eng Phys 2013; 35:926-36. [DOI: 10.1016/j.medengphy.2012.09.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2012] [Revised: 08/03/2012] [Accepted: 09/02/2012] [Indexed: 11/17/2022]
|
29
|
Strydom T, Hanekom JJ. The performance of different synthesis signals in acoustic models of cochlear implants. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 129:920-933. [PMID: 21361449 DOI: 10.1121/1.3518760] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Synthesis (carrier) signals in acoustic models embody assumptions about perception of auditory electric stimulation. This study compared speech intelligibility of consonants and vowels processed through a set of nine acoustic models that used Spectral Peak (SPEAK) and Advanced Combination Encoder (ACE)-like speech processing, using synthesis signals which were representative of signals used previously in acoustic models as well as two new ones. Performance of the synthesis signals was determined in terms of correspondence with cochlear implant (CI) listener results for 12 attributes of phoneme perception (consonant and vowel recognition; F1, F2, and duration information transmission for vowels; voicing, manner, place of articulation, affrication, burst, nasality, and amplitude envelope information transmission for consonants) using four measures of performance. Modulated synthesis signals produced the best correspondence with CI consonant intelligibility, while sinusoids, narrow noise bands, and varying noise bands produced the best correspondence with CI vowel intelligibility. The signals that performed best overall (in terms of correspondence with both vowel and consonant attributes) were modulated and unmodulated noise bands of varying bandwidth that corresponded to a linearly varying excitation width of 0.4 mm at the apical to 8 mm at the basal channels.
Collapse
Affiliation(s)
- Trudie Strydom
- Department of Electrical, Electronic, and Computer Engineering, University of Pretoria, Pretoria 0002, South Africa
| | | |
Collapse
|
30
|
Bierer JA. Probing the electrode-neuron interface with focused cochlear implant stimulation. Trends Amplif 2010; 14:84-95. [PMID: 20724356 DOI: 10.1177/1084713810375249] [Citation(s) in RCA: 91] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Cochlear implants are highly successful neural prostheses for persons with severe or profound hearing loss who gain little benefit from hearing aid amplification. Although implants are capable of providing important spectral and temporal cues for speech perception, performance on speech tests is variable across listeners. Psychophysical measures obtained from individual implant subjects can also be highly variable across implant channels. This review discusses evidence that such variability reflects deviations in the electrode-neuron interface, which refers to an implant channel's ability to effectively stimulate the auditory nerve. It is proposed that focused electrical stimulation is ideally suited to assess channel-to-channel irregularities in the electrode-neuron interface. In implant listeners, it is demonstrated that channels with relatively high thresholds, as measured with the tripolar configuration, exhibit broader psychophysical tuning curves and smaller dynamic ranges than channels with relatively low thresholds. Broader tuning implies that frequency-specific information intended for one population of neurons in the cochlea may activate more distant neurons, and a compressed dynamic range could make it more difficult to resolve intensity-based information, particularly in the presence of competing noise. Degradation of both types of cues would negatively affect speech perception.
Collapse
Affiliation(s)
- Julie Arenberg Bierer
- Department of Speech & Hearing Sciences, University of Washington, 1417 NE 42nd Street, Seattle,WA 98105-6246, USA.
| |
Collapse
|
31
|
Hu N, Miller CA, Abbas PJ, Robinson BK, Woo J. Changes in auditory nerve responses across the duration of sinusoidally amplitude-modulated electric pulse-train stimuli. J Assoc Res Otolaryngol 2010; 11:641-56. [PMID: 20632064 PMCID: PMC2975883 DOI: 10.1007/s10162-010-0225-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2009] [Accepted: 06/17/2010] [Indexed: 10/19/2022] Open
Abstract
Response rates of auditory nerve fibers (ANFs) to electric pulse trains change over time, reflecting substantial spike-rate adaptation that depends on stimulus parameters. We hypothesize that adaptation affects the representation of amplitude-modulated pulse trains used by cochlear prostheses to transmit speech information to the auditory system. We recorded cat ANF responses to sinusoidally amplitude-modulated (SAM) trains with 5,000 pulse/s carriers. Stimuli delivered by a monopolar intracochlear electrode had fixed modulation frequency (100 Hz) and depth (10%). ANF responses were assessed by spike-rate measures, while representation of modulation was evaluated by vector strength (VS) and the fundamental component of the fast Fourier transform (F(0) amplitude). These measures were assessed across the 400 ms duration of pulse-train stimuli, a duration relevant to speech stimuli. Different stimulus levels were explored and responses were categorized into four spike-rate groups to assess level effects across ANFs. The temporal pattern of rate adaptation to modulated trains was similar to that of unmodulated trains, but with less rate adaptation. VS to the modulator increased over time and tended to saturate at lower spike rates, while F(0) amplitude typically decreased over time for low driven rates and increased for higher driven rates. VS at moderate and high spike rates and degree of F(0) amplitude temporal changes at low and moderate spike rates were positively correlated with the degree of rate adaptation. Thus, high-rate carriers will modify the ANF representation of the modulator over time. As the VS and F(0) measures were sensitive to adaptation-related changes over different spike-rate ranges, there is value in assessing both measures.
Collapse
Affiliation(s)
- Ning Hu
- Department of Otolaryngology, University of Iowa Hospitals and Clinics, Iowa City, IA 52242 USA
- Hough Ear Institute, P.O. Box 23306, Oklahoma City, OK 73123-2206 USA
| | - Charles A. Miller
- Department of Otolaryngology, University of Iowa Hospitals and Clinics, Iowa City, IA 52242 USA
- Department of Communication Science and Disorders, University of Iowa, Wendell Johnson Speech and Hearing Center, Iowa City, IA 52242 USA
| | - Paul J. Abbas
- Department of Otolaryngology, University of Iowa Hospitals and Clinics, Iowa City, IA 52242 USA
- Department of Communication Science and Disorders, University of Iowa, Wendell Johnson Speech and Hearing Center, Iowa City, IA 52242 USA
| | - Barbara K. Robinson
- Department of Otolaryngology, University of Iowa Hospitals and Clinics, Iowa City, IA 52242 USA
| | - Jihwan Woo
- Department of Otolaryngology, University of Iowa Hospitals and Clinics, Iowa City, IA 52242 USA
| |
Collapse
|
32
|
Bierer JA, Bierer SM, Middlebrooks JC. Partial tripolar cochlear implant stimulation: Spread of excitation and forward masking in the inferior colliculus. Hear Res 2010; 270:134-42. [PMID: 20727397 DOI: 10.1016/j.heares.2010.08.006] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2010] [Revised: 07/15/2010] [Accepted: 08/12/2010] [Indexed: 12/01/2022]
Abstract
This study examines patterns of neural activity in response to single biphasic electrical pulses, presented alone or following a forward masking pulse train, delivered by a cochlear implant. Recordings were made along the tonotopic axis of the central nucleus of the inferior colliculus (ICC) in ketamine/xylazine anesthetized guinea pigs. The partial tripolar electrode configuration was used, which provided a systematic way to vary the tonotopic extent of ICC activation between monopolar (broad) and tripolar (narrow) extremes while maintaining the same peak of activation. The forward masking paradigm consisted of a 200 ms masker pulse train (1017 pulses per second) followed 10 ms later by a single-pulse probe stimulus; the current fraction of the probe was set to 0 (monopolar), 1 (tripolar), or 0.5 (hybrid), and the fraction of the masker was fixed at 0.5. Forward masking tuning profiles were derived from the amount of masking current required to just suppress the activity produced by a fixed-level probe. These profiles were sharper for more focused probe configurations, approximating the pattern of neural activity elicited by single (non-masked) pulses. The result helps to bridge the gap between previous findings in animals and recent psychophysical data.
Collapse
|
33
|
Smit JE, Hanekom T, van Wieringen A, Wouters J, Hanekom JJ. Threshold predictions of different pulse shapes using a human auditory nerve fibre model containing persistent sodium and slow potassium currents. Hear Res 2010; 269:12-22. [PMID: 20708672 DOI: 10.1016/j.heares.2010.08.004] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2009] [Revised: 06/29/2010] [Accepted: 08/04/2010] [Indexed: 11/25/2022]
Abstract
The ability of a human auditory nerve fibre computational model to predict threshold differences for biphasic, pseudomonophasic and alternating monophasic waveforms was investigated. The effect of increasing the interphase gap, interpulse interval and pulse rate on thresholds was also simulated. Simulations were performed for both anodic-first and cathodic-first stimuli. Results indicated that the model correctly predicted threshold reductions for pseudomonophasic compared to biphasic waveforms, although reduction for alternating monophasic waveforms was underestimated. Threshold reductions were more pronounced for cathodic-first stimuli compared to anodic-first stimuli. Reversal of the phases in pseudomonophasic stimuli suggested a threshold reduction for anodic-first stimuli, but a threshold increase in cathodic-first stimuli. Inclusion of the persistent sodium and slow potassium currents in the model resulted in a reasonably accurate prediction of the non-monotonic threshold behaviour for pulse rates higher than 1000 pps. However, the model did not correctly predict the threshold changes observed for low pulse rate biphasic and alternating monophasic waveforms. It was suggested that these results could in part be explained by the difference in the refractory periods between real and simulated auditory nerve fibres, but also by the lack of representation of stochasticity observed in real auditory nerve fibres in our auditory nerve model.
Collapse
Affiliation(s)
- Jacoba E Smit
- Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Pretoria, South Africa.
| | | | | | | | | |
Collapse
|
34
|
Selective electrical stimulation of the auditory nerve activates a pathway specialized for high temporal acuity. J Neurosci 2010; 30:1937-46. [PMID: 20130202 DOI: 10.1523/jneurosci.4949-09.2010] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Deaf people who use cochlear implants show surprisingly poor sensitivity to the temporal fine structure of sounds. One possible reason is that conventional cochlear implants cannot activate selectively the auditory-nerve fibers having low characteristic frequencies (CFs), which, in normal hearing, phase lock to stimulus fine structure. Recently, we tested in animals an alternative mode of auditory prosthesis using penetrating auditory-nerve electrodes that permit frequency-specific excitation in all frequency regions. We present here measures of temporal transmission through the auditory brainstem, from pulse trains presented with various auditory-nerve electrodes to phase-locked activity of neurons in the central nucleus of the inferior colliculus (ICC). On average, intraneural stimulation resulted in significant ICC phase locking at higher pulse rates (i.e., higher "limiting rates") than did cochlear-implant stimulation. That could be attributed, however, to the larger percentage of low-CF neurons activated selectively by intraneural stimulation. Most ICC neurons with limiting rates >500 pulses per second had CFs <1.5 kHz, whereas neurons with lower limiting rates tended to have higher CFs. High limiting rates also correlated strongly with short first-spike latencies. It follows that short latencies correlated significantly with low CFs, opposite to the correlation observed with acoustical stimulation. These electrical-stimulation results reveal a high-temporal-acuity brainstem pathway characterized by low CFs, short latencies, and high-fidelity transmission of periodic stimulation. Frequency-specific stimulation of that pathway by intraneural stimulation might improve temporal acuity in human users of a future auditory prosthesis, which in turn might improve musical pitch perception and speech reception in noise.
Collapse
|
35
|
Woo J, Miller CA, Abbas PJ. The dependence of auditory nerve rate adaptation on electric stimulus parameters, electrode position, and fiber diameter: a computer model study. J Assoc Res Otolaryngol 2009; 11:283-96. [PMID: 20033248 DOI: 10.1007/s10162-009-0199-2] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2009] [Accepted: 11/12/2009] [Indexed: 10/20/2022] Open
Abstract
This paper describes results from a stochastic computational neuron model that simulates the effects of rate adaptation on the responses to electrical stimulation in the form of pulse trains. We recently reported results from a single-node computational model that included a novel element that tracks external potassium ion concentration so as to modify membrane voltage and cause adaptation-like responses. Here, we report on an improved version of the model that incorporates the anatomical components of a complete feline auditory nerve fiber (ANF) so that conduction velocity and effects of manipulating the site of excitation can be evaluated. Model results demonstrate rate adaptation and changes in spike amplitude similar to those reported for feline ANFs. Changing the site of excitation from a central to a peripheral axonal site resulted in plausible changes in latency and relative spread (i.e., dynamic range). Also, increasing the distance between a modeled ANF and a stimulus electrode tended to decrease the degree of rate adaptation observed in pulse-train responses. This effect was clearly observed for high-rate (5,000 pulse/s) trains but not low-rate (250 pulse/s) trains. Finally, for relatively short electrode-to-ANF distances, increases in modeled ANF diameter increased the degree of rate adaptation. These results are compared against available feline ANF data, and possible effects of individual parameters are discussed.
Collapse
Affiliation(s)
- Jihwan Woo
- Department of Otolaryngology, University of Iowa Hospitals and Clinics, Iowa City, IA 52242, USA.
| | | | | |
Collapse
|
36
|
Runge-Samuelson CL. Effects of high-rate pulse trains on electrode discrimination in cochlear implant users. Trends Amplif 2009; 13:76-86. [PMID: 19447763 DOI: 10.1177/1084713809336739] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Overcoming issues related to abnormally high neural synchrony in response to electrical stimulation is one aspect in improving hearing with a cochlear implant. Desynchronization of electrical stimuli have shown benefits in neural encoding of electrical signals and improvements in psychophysical tasks. In the present study, 10 participants with either CII or HiRes 90k Advanced Bionics devices were tested for the effects of desynchronizing constant-amplitude high-rate (5,000 Hz) pulse trains on electrode discrimination of sinusoidal stimuli (1,000 Hz). When averaged across the sinusoidal dynamic range, overall improvements in electrode discrimination with high-rate pulses were found for 8 of 10 participants. This effect was significant for the group (p = .003). Nonmonotonic patterns of electrode discrimination as a function of sinusoidal stimulation level were observed. By providing additional spectral channels, it is possible that clinical implementation of constant-amplitude high-rate pulse trains in a signal processing strategy may improve performance with the device.
Collapse
Affiliation(s)
- Christina L Runge-Samuelson
- Department of Otolaryngology and Communication Sciences, Medical College of Wisconsin, 9200 W. Wisconsin Avenue, Milwaukee, WI 53226, USA.
| |
Collapse
|
37
|
O'Gorman DE, White JA, Shera CA. Dynamical instability determines the effect of ongoing noise on neural firing. J Assoc Res Otolaryngol 2009; 10:251-67. [PMID: 19308644 DOI: 10.1007/s10162-008-0148-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2008] [Accepted: 11/12/2008] [Indexed: 11/27/2022] Open
Abstract
At low stimulation rates, electrically stimulated auditory nerve fibers typically fire regularly, in lock-step to the applied stimulus. At high stimulation rates, however, these same fibers fire irregularly. Firing irregularity has been attributed to the random opening and closing of voltage-gated sodium channels at the spike generation site. We demonstrate, however, that the nonlinear dynamics of neural excitation and refractoriness embodied in the FitzHugh-Nagumo (FN) model produce realistic firing irregularity at high stimulus rates, even in the complete absence of ongoing physiological noise. Indeed, we show that ongoing noise can actually regularize the response at low discharge rates. The degree of stimulus-dependent irregularity is determined not so much by the level of ongoing physiological noise as by the dynamical instability. Our work suggests that the dynamical instability, quantified by the Lyapunov exponent, controls neural sensitivity to input signals and to physiological noise, as well the amount of mutual desynchronization between similarly stimulated fibers. This instability, quantified by the value of the Lyapunov exponent, may play a critical role in determining modulation sensitivity and dynamic range in cochlear implants.
Collapse
Affiliation(s)
- David E O'Gorman
- Eaton-Peabody Laboratory of Auditory Physiology, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, MA 02114, USA.
| | | | | |
Collapse
|
38
|
Affiliation(s)
- Marc D. Binder
- Department of Physiology & Biophysics, University of Washington School of Medicine, Seattle Washington, USA
| | - Nobutaka Hirokawa
- Department of Cell Biology and Anatomy, Graduate School of Medicine University of Tokyo Hongo, Bunkyo‐ku Tokyo, Japan
| | | |
Collapse
|
39
|
Jeng FC, Abbas PJ, Hu N, Miller CA, Nourski KV, Robinson BK. Effects of temporal properties on compound action potentials in response to amplitude-modulated electric pulse trains in guinea pigs. Hear Res 2009; 247:47-59. [DOI: 10.1016/j.heares.2008.10.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2008] [Revised: 10/21/2008] [Accepted: 10/25/2008] [Indexed: 11/27/2022]
|
40
|
Colburn HS, Chung Y, Zhou Y, Brughera A. Models of brainstem responses to bilateral electrical stimulation. J Assoc Res Otolaryngol 2008; 10:91-110. [PMID: 18941838 DOI: 10.1007/s10162-008-0141-z] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2007] [Accepted: 09/15/2008] [Indexed: 10/21/2022] Open
Abstract
A simple, biophysically specified cell model is used to predict responses of binaurally sensitive neurons to patterns of input spikes that represent stimulation by acoustic and electric waveforms. Specifically, the effects of changes in parameters of input spike trains on model responses to interaural time difference (ITD) were studied for low-frequency periodic stimuli, with or without amplitude modulation. Simulations were limited to purely excitatory, bilaterally driven cell models with basic ionic currents and multiple input fibers. Parameters explored include average firing rate, synchrony index, modulation frequency, and latency dispersion of the input trains as well as the excitatory conductance and time constant of individual synapses in the cell model. Results are compared to physiological recordings from the inferior colliculus (IC) and discussed in terms of ITD-discrimination abilities of listeners with cochlear implants. Several empirically observed aspects of ITD sensitivity were simulated without evoking complex neural processing. Specifically, our results show saturation effects in rate-ITD curves, the absence of sustained responses to high-rate unmodulated pulse trains, the renewal of sensitivity to ITD in high-rate trains when inputs are amplitude-modulated, and interactions between envelope and fine-structure delays for some modulation frequencies.
Collapse
Affiliation(s)
- H Steven Colburn
- Department of Biomedical Engineering, Center for Hearing Research, Boston University, Boston, MA 02215, USA.
| | | | | | | |
Collapse
|
41
|
Middlebrooks JC. Cochlear-implant high pulse rate and narrow electrode configuration impair transmission of temporal information to the auditory cortex. J Neurophysiol 2008; 100:92-107. [PMID: 18450583 PMCID: PMC2493502 DOI: 10.1152/jn.01114.2007] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2007] [Accepted: 04/25/2008] [Indexed: 11/22/2022] Open
Abstract
In the most commonly used cochlear prosthesis systems, temporal features of sound are signaled by amplitude modulation of constant-rate pulse trains. Several convincing arguments predict that speech reception should be optimized by use of pulse rates > or approximately 2,000 pulses per second (pps) and by use of intracochlear electrode configurations that produce restricted current spread (e.g., bipolar rather than monopolar configurations). Neither of those predictions has been borne out in consistent improvements in speech reception. Neurons in the auditory cortex of anesthetized guinea pigs phase lock to the envelope of sine-modulated electric pulse trains presented through a cochlear implant. The present study used that animal model to quantify the effects of carrier pulse rate, electrode configuration, current level, and modulator wave shape on transmission of temporal information from a cochlear implant to the auditory cortex. Modulation sensitivity was computed using a signal-detection analysis of cortical phase-locking vector strengths. Increasing carrier pulse rate in 1-octave steps from 254 to 4,069 pps resulted in systematic decreases in sensitivity. Comparison of sine- versus square-wave modulator waveforms demonstrated that some, but not all, of the loss of modulation sensitivity at high pulse rates was a result of the decreasing size of pulse-to-pulse current steps at the higher rates. Use of a narrow bipolar electrode configuration, compared with the monopolar configuration, produced a marked decrease in modulation sensitivity. Results from this animal model suggest explanations for the failure of high pulse rates and/or bipolar electrode configurations to produce hoped-for improvements in speech reception.
Collapse
Affiliation(s)
- John C Middlebrooks
- Department of Otolaryngology Head and Neck Surgery, Kresge Hearing Research Institute, University of Michigan, Ann Arbor, Michigan, USA.
| |
Collapse
|
42
|
van Wieringen A, Macherey O, Carlyon RP, Deeks JM, Wouters J. Alternative pulse shapes in electrical hearing. Hear Res 2008; 242:154-63. [PMID: 18468821 DOI: 10.1016/j.heares.2008.03.005] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2007] [Revised: 03/27/2008] [Accepted: 03/28/2008] [Indexed: 11/30/2022]
Abstract
Cochlear implants (CIs) stimulate the auditory nerve with trains of symmetric biphasic (BI) pulses. We review studies showing that more efficient stimulation can be achieved by modifying these pulses by (1) increasing the inter-phase gap (IPG) between the two phases of each pulse, thereby delaying the recovery of charge, (2) increasing the duration and decreasing the amplitude of one phase - so-called "pseudomonophasic (PS)" waveforms, and (3) combining the pseudomonophasic stimulus with an IPG in a "delayed pseudomonophasic" waveform (PS_IPG). These efficiency gains, measured using changes in threshold and loudness, occur at a wide range of pulse rates, including those commonly used in current CI systems. In monopolar mode, dynamic ranges are larger for PS and for long-IPG pulse shapes than for BI pulses, but this increase in DR is not accompanied by a higher number of discriminable loudness steps, and hence, in a better coding of loudness. Moreover, waveforms with relatively short and long interphase gaps do not yield different patterns of excitation despite the relatively large differences in threshold. Two important findings are that, contrary to data obtained in animal experiments, anodic currents are more effective than cathodic stimulation for human CI patients and that the thresholds decrease with increases in IPG over a much longer time course (more than 3 ms) than for animals. In this review it is discussed how these alternative pulse shapes may be beneficial in terms of reducing power consumption and channel interactions, which issues remain to be addressed, and how models contribute to guiding our research.
Collapse
Affiliation(s)
- Astrid van Wieringen
- ExpORL, Department of Neurosciences, Katholieke Universiteit Leuven, Herestraat 49 bus 721, B-3000 Leuven, Belgium.
| | | | | | | | | |
Collapse
|
43
|
Smith ZM, Delgutte B. Sensitivity to interaural time differences in the inferior colliculus with bilateral cochlear implants. J Neurosci 2007; 27:6740-50. [PMID: 17581961 PMCID: PMC2041852 DOI: 10.1523/jneurosci.0052-07.2007] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Bilateral cochlear implantation attempts to increase performance over a monaural prosthesis by harnessing the binaural processing of the auditory system. Although many bilaterally implanted human subjects discriminate interaural time differences (ITDs), a major cue for sound localization and signal detection in noise, their performance is typically poorer than that of normal-hearing listeners. We developed an animal model of bilateral cochlear implantation to study neural ITD sensitivity for trains of electric current pulses delivered via bilaterally implanted intracochlear electrodes. We found that a majority of single units in the inferior colliculus of acutely deafened, anesthetized cats are sensitive to ITD and that electric ITD tuning is as sharp as found for acoustic stimulation with broadband noise in normal-hearing animals. However, the sharpness and shape of ITD tuning often depended strongly on stimulus intensity; some neurons had dynamic ranges of ITD sensitivity as low as 1 dB. We also found that neural ITD sensitivity was best at pulse rates below 100 Hz and decreased with increasing pulse rate. This rate limitation parallels behavioral ITD discrimination in bilaterally implanted individuals. The sharp neural ITD sensitivity found with electric stimulation at the appropriate intensity is encouraging for the prospect of restoring the functional benefits of binaural hearing in bilaterally implanted human subjects and suggests that neural plasticity resulting from previous deafness and deprivation of binaural experience may play a role in the poor ITD discrimination with current bilateral implants.
Collapse
Affiliation(s)
- Zachary M Smith
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts 02114, USA.
| | | |
Collapse
|
44
|
Zhang F, Miller CA, Robinson BK, Abbas PJ, Hu N. Changes across time in spike rate and spike amplitude of auditory nerve fibers stimulated by electric pulse trains. J Assoc Res Otolaryngol 2007; 8:356-72. [PMID: 17562109 PMCID: PMC2538432 DOI: 10.1007/s10162-007-0086-7] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2006] [Accepted: 05/07/2007] [Indexed: 10/23/2022] Open
Abstract
We undertook a systematic evaluation of spike rates and spike amplitudes of auditory nerve fiber (ANF) responses to trains of electric current pulses. Measures were obtained from acutely deafened cats to examine time-related changes free from the effects of hair-cell and synaptic adaptation. Such data relate to adaptation that likely occurs in ANFs of cochlear-implant users. A major goal was to determine and compare rate adaptation observed at different pulse rates (primarily 250, 1000, and 5000 pulse/s) and describe them using decaying exponential models similar to those used in acoustic studies. Rate-vs.-time functions were best described by two-exponent models and produced time constants similar to (although slightly greater than) the "rapid" and "short-term" components described in acoustic studies. There was little dependence of these time constants on onset spike rate, but pulse-rate effects were noted. Spike amplitude changes followed a time course different from that of rate adaptation consistent with a process related to ANF interspike intervals. The fact that two time constants governed rate adaptation in electrically stimulated and deafened fibers suggests that future computational models of adaptation should not only include hair cell and synapse components, but also components determined by fiber membrane characteristics.
Collapse
Affiliation(s)
- Fawen Zhang
- Department of Otolaryngology, University of Iowa Hospitals and Clinics, 21201 PFP, 200 Hawkins Drive, Iowa City, IA 52242 USA
- Department of Speech Pathology and Audiology, Wendell Johnson Speech and Hearing Center, University of Iowa, Iowa City, IA 52242 USA
| | - Charles A. Miller
- Department of Otolaryngology, University of Iowa Hospitals and Clinics, 21201 PFP, 200 Hawkins Drive, Iowa City, IA 52242 USA
- Department of Speech Pathology and Audiology, Wendell Johnson Speech and Hearing Center, University of Iowa, Iowa City, IA 52242 USA
| | - Barbara K. Robinson
- Department of Otolaryngology, University of Iowa Hospitals and Clinics, 21201 PFP, 200 Hawkins Drive, Iowa City, IA 52242 USA
| | - Paul J. Abbas
- Department of Otolaryngology, University of Iowa Hospitals and Clinics, 21201 PFP, 200 Hawkins Drive, Iowa City, IA 52242 USA
- Department of Speech Pathology and Audiology, Wendell Johnson Speech and Hearing Center, University of Iowa, Iowa City, IA 52242 USA
| | - Ning Hu
- Department of Otolaryngology, University of Iowa Hospitals and Clinics, 21201 PFP, 200 Hawkins Drive, Iowa City, IA 52242 USA
| |
Collapse
|
45
|
Joris PX, Louage DH, Cardoen L, van der Heijden M. Correlation index: a new metric to quantify temporal coding. Hear Res 2006; 216-217:19-30. [PMID: 16644160 DOI: 10.1016/j.heares.2006.03.010] [Citation(s) in RCA: 77] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2005] [Revised: 03/01/2006] [Accepted: 03/07/2006] [Indexed: 12/01/2022]
Abstract
The standard procedure to study temporal encoding of sound waveforms in the auditory system has been Fourier analysis of responses to periodic stimuli. We introduce a new metric--correlation index (CI)--which is based on a simple counting of spike coincidences. It can be used for responses to aperiodic stimuli and does not require knowledge of the stimulus. Moreover, the basic procedure of comparing spiketimes in spiketrains is more physiological than currently used methods for temporal analysis. The CI is the peak value of the normalized shuffled autocorrelogram (SAC), which provides a quantitative summary of temporal structure in the neural response to arbitrary stimuli. We illustrate the CI and SACs by comparing temporal coding in the auditory nerve and output fibers of the cochlear nucleus.
Collapse
Affiliation(s)
- Philip X Joris
- Laboratory of Auditory Neurophysiology, K.U. Leuven, Medical School, Campus Gasthuisberg O&N2 bus 1021, Herestraat 49, B-3000 Leuven, Belgium.
| | | | | | | |
Collapse
|
46
|
Cartee LA, Miller CA, van den Honert C. Spiral ganglion cell site of excitation I: comparison of scala tympani and intrameatal electrode responses. Hear Res 2006; 215:10-21. [PMID: 16624511 DOI: 10.1016/j.heares.2006.02.012] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2006] [Accepted: 02/28/2006] [Indexed: 11/27/2022]
Abstract
To determine the site of excitation on the spiral ganglion cell in response to electrical stimulation similar to that from a cochlear implant, single-fiber responses to electrical stimuli delivered by an electrode positioned in the scala tympani were compared to responses from stimuli delivered by an electrode placed in the internal auditory meatus. The response to intrameatal stimulation provided a control set of data with a known excitation site, the central axon of the spiral ganglion cell. For both intrameatal and scala tympani stimuli, the responses to single-pulse, summation, and refractory stimulus protocols were recorded. The data demonstrated that summation pulses, as opposed to single pulses, are likely to give the most insightful measures for determination of the site of excitation. Single-fiber summation data for both scala tympani and intrameatally stimulated fibers were analyzed with a clustering algorithm. Combining cluster analysis and additional numerical modeling data, it was hypothesized that the scala tympani responses corresponded to central excitation, peripheral excitation adjacent to the cell body, and peripheral excitation at a site distant from the cell body. Fibers stimulated by an intrameatal electrode demonstrated the greatest range of jitter measurements indicating that greater fiber independence may be achieved with intrameatal stimulation.
Collapse
Affiliation(s)
- Lianne A Cartee
- Joint Department of Biomedical Engineering, North Carolina State University and the University of North Carolina at Chapel Hill, Box 7625, Raleigh, NC 27695, USA.
| | | | | |
Collapse
|
47
|
Affiliation(s)
- Colette M McKay
- School of Life and Health Sciences, Aston University, Birmingham B4 7ET, United Kingdom
| |
Collapse
|
48
|
Zeng FG, Chen H, Han S. Temporal masking in electric hearing. J Assoc Res Otolaryngol 2006; 6:390-400. [PMID: 16261267 PMCID: PMC2504624 DOI: 10.1007/s10162-005-0016-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2005] [Accepted: 08/26/2005] [Indexed: 10/25/2022] Open
Abstract
Temporal masking can be defined as the detection threshold of a brief signal as a function of the signal delay in a relatively long masker. The temporal masking pattern in normal acoustic hearing reveals temporal edge enhancement in which the signal detection threshold is greater near the masker onset than in the steady-state portion. Both peripheral and central mechanisms appear to underlie temporal edge enhancement, but their relative contributions remain elusive. Cochlear implants bypass cochlear mechanical processing and stimulate the auditory nerve directly, thereby providing a unique opportunity to separate the peripheral mechanisms from the central mechanisms. Here, we systematically measured temporal masking in electric hearing by examining whether a brief signal was harder to detect at the onset than in the steady-state portion of a long masker (the "overshoot" effect). The signal and the masker were presented (1) either to the same electrode or to different electrodes, (2) at the same stimulation or different rates, and (3) in a simultaneous or an interleaved fashion. A consistent pattern of results was observed, depending on the stimulus configuration between the signal and the masker. Simultaneous stimulation at the same rate and with the same electrode produced no difference in sensitivity between the onset and the steady-state conditions, but interleaved stimulation at different rates or with different electrodes produced a significant difference. Unlike acoustic hearing, high masker levels produced an overshoot effect, and low masker levels produced an undershoot effect. Although the present results are consistent with the "on-frequency vs. off-frequency" hypothesis for the overshoot effect, results also suggest a central "same vs. different" mechanism underlying temporal masking. These results have practical implications for improving cochlear implant design.
Collapse
Affiliation(s)
- Fan-Gang Zeng
- Department of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences and Otolaryngology - Head and Neck Surgery, University of California, Irvine, CA 92697, USA.
| | | | | |
Collapse
|
49
|
Tang Q, Liu S, Zeng FG. Loudness adaptation in acoustic and electric hearing. J Assoc Res Otolaryngol 2006; 7:59-70. [PMID: 16425088 PMCID: PMC2504588 DOI: 10.1007/s10162-005-0023-6] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2005] [Accepted: 11/29/2005] [Indexed: 10/25/2022] Open
Abstract
The present study is aimed to evaluate and compare loudness adaptation between normal hearing and cochlear-implant subjects. Loudness adaptation for 367-s pure tones was measured in five normal-hearing subjects at three frequencies (125, 1,000, and 8,000 Hz) and three levels (30, 60, and 90 dB SPL). In addition, loudness adaptation for 367-s pulse trains was measured in five Clarion cochlear-implant subjects at three stimulation rates (100, 991, and 4,296 Hz), three levels (10, 50, and 90% of the electric dynamic range), three stimulation positions (apical, middle and basal), and two stimulation modes (monopolar and bipolar). The method of successive magnitude estimation was used to quantify loudness adaptation. Similar to the previous results, we found that loudness adaptation in normal-hearing subjects increases with decreasing level and increasing frequency. However, we also found a small but significant loudness enhancement at 90 dB SPL in acoustic hearing. Despite large individual variability, we found that loudness adaptation in cochlear-implant subjects increases with decreasing levels, but is not significantly affected by the rate, place and mode of stimulation. A phenomenological model was proposed to predict loudness adaptation as a function of stimulus frequency and level in acoustic hearing. The present results were not fully compatible with either the restricted excitation hypothesis or the neural adaptation hypothesis. Loudness adaptation may have a central component that is dependent on the peripheral excitation pattern.
Collapse
Affiliation(s)
- Qing Tang
- Department of Anatomy and Neurobiology, University of California, Irvine, CA 92697 USA
- Department of Biomedical Engineering, University of California, Irvine, CA 92697 USA
- Department of Cognitive Sciences and Otolaryngology–Head and Neck Surgery, University of California, Irvine, CA 92697 USA
- Hearing and Speech Research Laboratory, University of California, 364 Med Surge II, Irvine, CA 92697-1275 USA
| | - Sheng Liu
- Department of Anatomy and Neurobiology, University of California, Irvine, CA 92697 USA
- Department of Biomedical Engineering, University of California, Irvine, CA 92697 USA
- Department of Cognitive Sciences and Otolaryngology–Head and Neck Surgery, University of California, Irvine, CA 92697 USA
| | - Fan-Gang Zeng
- Department of Anatomy and Neurobiology, University of California, Irvine, CA 92697 USA
- Department of Biomedical Engineering, University of California, Irvine, CA 92697 USA
- Department of Cognitive Sciences and Otolaryngology–Head and Neck Surgery, University of California, Irvine, CA 92697 USA
- Hearing and Speech Research Laboratory, University of California, 364 Med Surge II, Irvine, CA 92697-1275 USA
| |
Collapse
|
50
|
Abstract
Cochlear implants provide functional hearing to the majority of recipients and have gained widespread acceptance clinically, but the range of performance remains great and largely unexplained. Designs for implanted electrodes and electronics have converged, whereas novel speech processing strategies have proliferated. For each patient, the fitting audiologist must sort empirically through options that produce large but idiosyncratic differences in both objective performance and subjective preference. This review and analysis suggests that the place-pitch and rate-pitch theories on which cochlear implants have been designed are incomplete. The missing component may be related to the phase-locking of auditory nerve activity to both acoustic and electrical stimulation. This component is likely to be highly distorted by electrical stimulation but its importance as one of several different pitch encoding mechanisms may vary widely among patients. Systematic means to control these putative phase effects using modern, high-speed, and high-density cochlear implants may make it possible to identify more efficiently the best strategy for a given patient and to minimize the perceptual confusion that arises from conflicting cues.
Collapse
Affiliation(s)
- Gerald E Loeb
- Department of Biomedical Engineering, Viterbi School of Engineering and A. E. Mann Institute for Biomedical Engineering, University of Southern California, Los Angeles 90089-1112, USA.
| |
Collapse
|