1
|
Deng L, Kumar J, Rose R, McIntyre W, Fabris D. Analyzing RNA posttranscriptional modifications to decipher the epitranscriptomic code. MASS SPECTROMETRY REVIEWS 2024; 43:5-38. [PMID: 36052666 DOI: 10.1002/mas.21798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 05/23/2022] [Accepted: 05/27/2022] [Indexed: 06/15/2023]
Abstract
The discovery of RNA silencing has revealed that non-protein-coding sequences (ncRNAs) can cover essential roles in regulatory networks and their malfunction may result in severe consequences on human health. These findings have prompted a general reassessment of the significance of RNA as a key player in cellular processes. This reassessment, however, will not be complete without a greater understanding of the distribution and function of the over 170 variants of the canonical ribonucleotides, which contribute to the breathtaking structural diversity of natural RNA. This review surveys the analytical approaches employed for the identification, characterization, and detection of RNA posttranscriptional modifications (rPTMs). The merits of analyzing individual units after exhaustive hydrolysis of the initial biopolymer are outlined together with those of identifying their position in the sequence of parent strands. Approaches based on next generation sequencing and mass spectrometry technologies are covered in depth to provide a comprehensive view of their respective merits. Deciphering the epitranscriptomic code will require not only mapping the location of rPTMs in the various classes of RNAs, but also assessing the variations of expression levels under different experimental conditions. The fact that no individual platform is currently capable of meeting all such demands implies that it will be essential to capitalize on complementary approaches to obtain the desired information. For this reason, the review strived to cover the broadest possible range of techniques to provide readers with the fundamental elements necessary to make informed choices and design the most effective possible strategy to accomplish the task at hand.
Collapse
Affiliation(s)
- L Deng
- Department of Chemistry, University of Connecticut, Storrs, Connecticut, USA
| | - J Kumar
- Department of Chemistry, University of Connecticut, Storrs, Connecticut, USA
| | - R Rose
- Department of Advanced Research Technologies, New York University Langone Health Center, New York, USA
| | - W McIntyre
- Department of Chemistry, University of Connecticut, Storrs, Connecticut, USA
| | - Daniele Fabris
- Department of Chemistry, University of Connecticut, Storrs, Connecticut, USA
| |
Collapse
|
2
|
Kenderdine T, McIntyre W, Yassaghi G, Rollo D, Bunkowski A, Goerlach L, Suckau D, Tremintin G, Greig M, Bell C, Fabris D. Integrating Internal Fragments in the Interpretation of Top-Down Sequencing Data of Larger Oligonucleotides. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:2296-2307. [PMID: 37729585 DOI: 10.1021/jasms.3c00207] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
In the context of direct top-down analysis or concerted bottom-up characterization of nucleic acid samples, the waning yield of terminal fragments as a function of precursor ion size poses a significant challenge to the gas-phase sequencing of progressively larger oligonucleotides. In this report, we examined the behavior of oligoribonucleotide samples ranging from 20 to 364 nt upon collision-induced dissociation (CID). The experimental data showed a progressive shift from terminal to internal fragments as a function of size. The systematic evaluation of experimental factors, such as collision energy, precursor charge, sample temperature, and the presence of chaotropic agents, showed that this trend could be modestly alleviated but not suppressed. This inexorable effect, which has been reported also for other activation techniques, prompted a re-examination of the features that have traditionally discouraged the utilization of internal fragments as a source of sequence information in data interpretation procedures. Our simulations highlighted the ability of internal fragments to produce self-consistent ladders with either end corresponding to each nucleotide in the sequence, which enables both proper alignment and correct recognition of intervening nucleotides. In turn, contiguous ladders display extensive overlaps with one another and with the ladders formed by terminal fragments, which unambiguously constrain their mutual placement within the analyte sequence. The experimental data borne out the predictions by showing ladders with extensive overlaps, which translated into uninterrupted "walks" covering the entire sequence with no gaps from end to end. More significantly, the results showed that combining the information afforded by internal and terminal ladders resulted in much a greater sequence coverage and nucleotide coverage depth than those achievable when either type of information was considered separately. The examination of a series of 58-mer oligonucleotides with high sequence homology showed that the assignment ambiguities engendered by internal fragments did not significantly exceed those afforded by the terminal ones. Therefore, the balance between potential benefits and perils of including the former makes a compelling argument for the development of integrated data interpretation strategies, which are better equipped for dealing with the changing fragmentation patterns obtained from progressively larger oligonucleotides.
Collapse
Affiliation(s)
| | - William McIntyre
- University of Connecticut, Storrs, Connecticut 06269, United States
| | | | - Daniele Rollo
- University of Connecticut, Storrs, Connecticut 06269, United States
| | | | | | - Detlev Suckau
- Bruker Daltonics GmbH & Co. KG, 28359 Bremen, Germany
| | | | - Michael Greig
- Bruker Scientific LLC, San Jose, California 95134, United States
| | | | - Daniele Fabris
- University of Connecticut, Storrs, Connecticut 06269, United States
- Ribodynamics LLC, Manchester, Connecticut 06040, United States
| |
Collapse
|
3
|
Kenderdine T, Fabris D. The multifaceted roles of mass spectrometric analysis in nucleic acids drug discovery and development. MASS SPECTROMETRY REVIEWS 2023; 42:1332-1357. [PMID: 34939674 PMCID: PMC9218015 DOI: 10.1002/mas.21766] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 09/23/2021] [Accepted: 11/22/2021] [Indexed: 06/07/2023]
Abstract
The deceptively simple concepts of mass determination and fragment analysis are the basis for the application of mass spectrometry (MS) to a boundless range of analytes, including fundamental components and polymeric forms of nucleic acids (NAs). This platform affords the intrinsic ability to observe first-hand the effects of NA-active drugs on the chemical structure, composition, and conformation of their targets, which might affect their ability to interact with cognate NAs, proteins, and other biomolecules present in a natural environment. The possibility of interfacing with high-performance separation techniques represents a multiplying factor that extends these capabilities to cover complex sample mixtures obtained from organisms that were exposed to NA-active drugs. This report provides a brief overview of these capabilities in the context of the analysis of the products of NA-drug activity and NA therapeutics. The selected examples offer proof-of-principle of the applicability of this platform to all phases of the journey undertaken by any successful NA drug from laboratory to bedside, and provide the rationale for its rapid expansion outside traditional laboratory settings in support to ever growing manufacturing operations.
Collapse
Affiliation(s)
| | - Dan Fabris
- Department of Chemistry, University of Connecticut
| |
Collapse
|
4
|
Santos IC, Lanzillotti M, Shilov I, Basanta-Sanchez M, Roushan A, Lawler R, Tang W, Bern M, Brodbelt JS. Ultraviolet Photodissociation and Activated Electron Photodetachment Mass Spectrometry for Top-Down Sequencing of Modified Oligoribonucleotides. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:510-520. [PMID: 35157441 DOI: 10.1021/jasms.1c00340] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
With the increased development of new RNA-based therapeutics, the need for robust analytical methods for confirming sequences and mapping modifications has accelerated. Characterizing modified ribonucleic acids using mass spectrometry is challenging because diagnostic fragmentation may be suppressed for modified nucleotides, thus hampering complete sequence coverage and the confident localization of modifications. Ultraviolet photodissociation (UVPD) has shown great potential for the characterization of nucleic acids due to extensive backbone fragmentation. Activated electron photodetachment dissociation (a-EPD) has also been used as an alternative to capitalize on the dominant charge-reduction pathway prevalent in UVPD, facilitate dissociation, and produce high abundances of fragment ions. Here, we compare higher-energy collisional activation (HCD), UVPD using 193 and 213 nm photons, and a-EPD for the top-down sequencing of modified nucleic acids, including methylated, phosphorothioate, and locked nucleic acid-modified DNA. The presence of these modifications alters the fragmentation pathways observed upon UVPD and a-EPD, and extensive backbone cleavage is observed that results in the production of fragment ions that retain the modifications and allow them to be pinpointed. LNA and 2'-O-methoxy phosphorothioate modifications caused a significant suppression of fragmentation for UVPD but not for a-EPD, whereas phosphorothioate bonds did not cause any significant suppression for either method. The incorporation of 2'-O-methyl modifications suppressed fragmentation of the antisense strand of patisiran, which resulted in some gaps in sequence coverage. However, UVPD provided the highest sequence coverage when compared to a-EPD.
Collapse
Affiliation(s)
- Inês C Santos
- Department of Chemistry, University of Texas at Austin, Austin, Texas 78712, United States
| | - Michael Lanzillotti
- Department of Chemistry, University of Texas at Austin, Austin, Texas 78712, United States
| | - Ignat Shilov
- Protein Metrics Inc., 20863 Stevens Creek Boulevard, Cupertino, California 95014, United States
| | - Maria Basanta-Sanchez
- Protein Metrics Inc., 20863 Stevens Creek Boulevard, Cupertino, California 95014, United States
| | - Abhishek Roushan
- Protein Metrics Inc., 20863 Stevens Creek Boulevard, Cupertino, California 95014, United States
| | - Rose Lawler
- Protein Metrics Inc., 20863 Stevens Creek Boulevard, Cupertino, California 95014, United States
| | - Wilfred Tang
- Protein Metrics Inc., 20863 Stevens Creek Boulevard, Cupertino, California 95014, United States
| | - Marshall Bern
- Protein Metrics Inc., 20863 Stevens Creek Boulevard, Cupertino, California 95014, United States
| | - Jennifer S Brodbelt
- Department of Chemistry, University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
5
|
Ultrafast enzymatic digestion of deoxyribonucleic acid in aqueous microdroplets for sequence discrimination and identification. QRB DISCOVERY 2021; 2:e4. [PMID: 34192264 PMCID: PMC8185430 DOI: 10.1017/qrd.2021.2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 04/05/2021] [Accepted: 05/07/2021] [Indexed: 12/31/2022] Open
Abstract
We report the use of aqueous microdroplets to accelerate deoxyribonucleic acid (DNA) fragmentation by deoxyribonuclease I (DNase I), and we present a simple, ultrafast approach named DNA fragment mass fingerprinting to discriminate different DNA sequences by comparing their fragment mass patterns. DNA fragmentation in tiny microdroplets, which was produced by electrosonically spraying (+3 kV) a room temperature aqueous solution containing 10 μM DNA and 10 μg ml−1 DNase I from a homemade setup, takes less than 1 ms. High differentiation/identification fidelity could be obtained by applying a cosine correlation measure for similarity assessment between two fragment mass patterns, which compares both mass-to-charge ratios (m/z) with an error tolerance of 5 ppm and the peaks’ relative intensities. A single-nucleotide mutation in the sequence of bases, as exemplified by the sickle cell anemia mutation, is differentiated by setting a cutoff value of similarity at 90%. The order change of two adjacent bases in the sequence could still be well discriminated with a similarity of only 62% between the fragment mass patterns of the two similar sequences, which have the same molecular weights and thus cannot be differentiated by gel electrophoresis or direct mass detection by mass spectrometry. Compared to traditional genotyping methods, such as quantitative real-time polymerase chain reaction, the identification process with our approach could be completed within several minutes without any other expensive and complicated reagents or experimental steps. The potential of our approach for convenient and fast microbe genetic discrimination or identification is further demonstrated by differentiating the Orf1ab gene fragments of two similar coronaviruses with a very high sequence homologous rate of 96%, SARS-CoV-2 and bat-SL-CoVZC45, with a similarity of 0% between their fragment mass patterns.
Collapse
|
6
|
Pourshahian S. THERAPEUTIC OLIGONUCLEOTIDES, IMPURITIES, DEGRADANTS, AND THEIR CHARACTERIZATION BY MASS SPECTROMETRY. MASS SPECTROMETRY REVIEWS 2021; 40:75-109. [PMID: 31840864 DOI: 10.1002/mas.21615] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Oligonucleotides are an emerging class of drugs that are manufactured by solid-phase synthesis. As a chemical class, they have unique product-related impurities and degradants, characterization of which is an essential step in drug development. The synthesis cycle, impurities produced during the synthesis and degradation products are presented and discussed. The use of liquid chromatography combined with mass spectrometry for characterization and quantification of product-related impurities and degradants is reviewed. In addition, sequence determination of oligonucleotides by gas-phase fragmentation and indirect mass spectrometric methods is discussed. © 2019 John Wiley & Sons Ltd. Mass Spec Rev.
Collapse
Affiliation(s)
- Soheil Pourshahian
- Janssen Pharmaceutical Companies of Johnson & Johnson, South San Francisco, CA, 94080
| |
Collapse
|
7
|
Yoluç Y, Ammann G, Barraud P, Jora M, Limbach PA, Motorin Y, Marchand V, Tisné C, Borland K, Kellner S. Instrumental analysis of RNA modifications. Crit Rev Biochem Mol Biol 2021; 56:178-204. [PMID: 33618598 DOI: 10.1080/10409238.2021.1887807] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Organisms from all domains of life invest a substantial amount of energy for the introduction of RNA modifications into nearly all transcripts studied to date. Instrumental analysis of RNA can focus on the modified residues and reveal the function of these epitranscriptomic marks. Here, we will review recent advances and breakthroughs achieved by NMR spectroscopy, sequencing, and mass spectrometry of the epitranscriptome.
Collapse
Affiliation(s)
- Yasemin Yoluç
- Department of Chemistry, Ludwig Maximilians University, Munich, Germany
| | - Gregor Ammann
- Department of Chemistry, Ludwig Maximilians University, Munich, Germany
| | - Pierre Barraud
- Expression génétique microbienne, UMR 8261, CNRS, Institut de biologie physico-chimique, IBPC, Université de Paris, Paris, France
| | - Manasses Jora
- Department of Chemistry, University of Cincinnati, Cincinnati, OH, USA
| | - Patrick A Limbach
- Department of Chemistry, University of Cincinnati, Cincinnati, OH, USA
| | - Yuri Motorin
- Université de Lorraine, CNRS, UMR7365 IMoPA, Nancy, France
| | - Virginie Marchand
- Université de Lorraine, CNRS, INSERM, Epitranscriptomics and RNA Sequencing Core facility, UM S2008, IBSLor, Nancy, France
| | - Carine Tisné
- Expression génétique microbienne, UMR 8261, CNRS, Institut de biologie physico-chimique, IBPC, Université de Paris, Paris, France
| | - Kayla Borland
- Department of Chemistry, Ludwig Maximilians University, Munich, Germany
| | - Stefanie Kellner
- Department of Chemistry, Ludwig Maximilians University, Munich, Germany.,Institute of Pharmaceutical Chemistry, Goethe-University, Frankfurt, Germany
| |
Collapse
|
8
|
Santos IC, Brodbelt JS. Recent developments in the characterization of nucleic acids by liquid chromatography, capillary electrophoresis, ion mobility, and mass spectrometry (2010-2020). J Sep Sci 2021; 44:340-372. [PMID: 32974962 PMCID: PMC8378248 DOI: 10.1002/jssc.202000833] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 09/18/2020] [Accepted: 09/21/2020] [Indexed: 12/25/2022]
Abstract
The development of new strategies for the analysis of nucleic acids has gained momentum due to the increased interest in using these biomolecules as drugs or drug targets. The application of new mass spectrometry ion activation techniques and the optimization of separation methods including liquid chromatography, capillary electrophoresis, and ion mobility have allowed more detailed characterization of nucleic acids and oligonucleotide therapeutics including confirmation of sequence, localization of modifications and interaction sites, and structural analysis as well as identification of failed sequences and degradation products. This review will cover tandem mass spectrometry methods as well as the recent developments in liquid chromatography, capillary electrophoresis, and ion mobility coupled to mass spectrometry for the analysis of nucleic acids and oligonucleotides.
Collapse
Affiliation(s)
- Inês C Santos
- Department of Chemistry, University of Texas at Austin, Austin, Texas, USA
| | | |
Collapse
|
9
|
Zhang N, Shi S, Jia TZ, Ziegler A, Yoo B, Yuan X, Li W, Zhang S. A general LC-MS-based RNA sequencing method for direct analysis of multiple-base modifications in RNA mixtures. Nucleic Acids Res 2020; 47:e125. [PMID: 31504795 PMCID: PMC6847078 DOI: 10.1093/nar/gkz731] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Revised: 08/07/2019] [Accepted: 08/15/2019] [Indexed: 12/31/2022] Open
Abstract
A complete understanding of the structural and functional potential of RNA requires understanding of chemical modifications and non-canonical bases; this in turn requires advances in current sequencing methods to be able to sequence not only canonical ribonucleotides, but at the same time directly sequence these non-standard moieties. Here, we present the first direct and modification type-independent RNA sequencing method via introduction of a 2-dimensional hydrophobic end-labeling strategy into traditional mass spectrometry-based sequencing (2D HELS MS Seq) to allow de novo sequencing of RNA mixtures and enhance sample usage efficiency. Our method can directly read out the complete sequence, while identifying, locating, and quantifying base modifications accurately in both single and mixed RNA samples containing multiple different modifications at single-base resolution. Our method can also quantify stoichiometry/percentage of modified RNA versus its canonical counterpart RNA, simulating a real biological sample where modifications exist but may not be 100% at a particular site in the RNA. This method is a critical step towards fully sequencing real complex cellular RNA samples of any type and containing any modification type and can also be used in the quality control of modified therapeutic RNAs.
Collapse
Affiliation(s)
- Ning Zhang
- Department of Biological and Chemical Sciences, New York Institute of Technology, New York, NY 10023, USA.,Department of Chemical Engineering, Columbia University, New York, NY 10027, USA
| | - Shundi Shi
- Department of Chemical Engineering, Columbia University, New York, NY 10027, USA
| | - Tony Z Jia
- Earth-Life Science Institute, Tokyo Institute of Technology, Meguro-ku, Tokyo 152-8550, Japan.,Blue Marble Space Institute of Science, Seattle, WA 98154, USA
| | - Ashley Ziegler
- Department of Biological and Chemical Sciences, New York Institute of Technology, New York, NY 10023, USA
| | - Barney Yoo
- Department of Chemistry, Hunter College, City University of New York, New York, NY 10065, USA
| | - Xiaohong Yuan
- Department of Biological and Chemical Sciences, New York Institute of Technology, New York, NY 10023, USA
| | - Wenjia Li
- Department of Computer Science, New York Institute of Technology, New York, NY 10023, USA
| | - Shenglong Zhang
- Department of Biological and Chemical Sciences, New York Institute of Technology, New York, NY 10023, USA
| |
Collapse
|
10
|
Brodbelt JS, Morrison LJ, Santos I. Ultraviolet Photodissociation Mass Spectrometry for Analysis of Biological Molecules. Chem Rev 2020; 120:3328-3380. [PMID: 31851501 PMCID: PMC7145764 DOI: 10.1021/acs.chemrev.9b00440] [Citation(s) in RCA: 139] [Impact Index Per Article: 34.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The development of new ion-activation/dissociation methods continues to be one of the most active areas of mass spectrometry owing to the broad applications of tandem mass spectrometry in the identification and structural characterization of molecules. This Review will showcase the impact of ultraviolet photodissociation (UVPD) as a frontier strategy for generating informative fragmentation patterns of ions, especially for biological molecules whose complicated structures, subtle modifications, and large sizes often impede molecular characterization. UVPD energizes ions via absorption of high-energy photons, which allows access to new dissociation pathways relative to more conventional ion-activation methods. Applications of UVPD for the analysis of peptides, proteins, lipids, and other classes of biologically relevant molecules are emphasized in this Review.
Collapse
Affiliation(s)
- Jennifer S. Brodbelt
- Department of Chemistry, University of Texas at Austin, Austin, Texas 78712, United States
| | - Lindsay J. Morrison
- Department of Chemistry, University of Texas at Austin, Austin, Texas 78712, United States
| | - Inês Santos
- Department of Chemistry, University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
11
|
Studzińska S. Review on investigations of antisense oligonucleotides with the use of mass spectrometry. Talanta 2017; 176:329-343. [PMID: 28917758 DOI: 10.1016/j.talanta.2017.08.025] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2017] [Revised: 08/03/2017] [Accepted: 08/07/2017] [Indexed: 11/17/2022]
Abstract
Antisense oligonucleotides have been investigated as potential drugs for years. They inhibit target gene or protein expression. The present review summarizes their modifications, modes of action, and applications of liquid chromatography coupled with mass spectrometry for qualitative and quantitative analysis of these compounds. The most recent reports on a given topic were given prominence, while some early studies were reviewed in order to provide a theoretical background. The present review covers the issues of using ion-exchange chromatography, ion-pair reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography for the separation of antisense oligonucleotides. The application of mass spectrometry was described with regard to the ionization type used for the determination of these potential therapeutics. Moreover, the current approaches and applications of mass spectrometry for quantitative analysis of antisense oligonucleotides and their metabolites as well as their impurities during in vitro and in vivo studies were discussed. Finally, certain conclusions and perspectives on the determination of therapeutic oligonucleotides in various samples were briefly described.
Collapse
Affiliation(s)
- Sylwia Studzińska
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University, 7 Gagarin Str., PL-87-100 Toruń, Poland.
| |
Collapse
|
12
|
Ross RL, Sauter AD, Limbach PA. Induction based fluidics (IBF) for droplet-based mass spectrometric analysis of oligonucleotides. JOURNAL OF MASS SPECTROMETRY : JMS 2015; 50:1175-1179. [PMID: 26456787 DOI: 10.1002/jms.3636] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2015] [Revised: 07/07/2015] [Accepted: 07/20/2015] [Indexed: 06/05/2023]
Abstract
Here, we report the utility of induction-based fluidics (IBF) for the introduction of oligonucleotides to a mass spectrometer via charged droplets. The device produces nanoliter-sized droplets, which are field transported with minimal concerns related to source plugging or sampling loss. The IBF source enabled detection of oligonucleotides at the nanomolar concentration level. Importantly, analysis of individual droplets revealed that oligonucleotide mixtures could be detected with ion abundance ratios that closely match the initial concentration ratios within the sample.
Collapse
Affiliation(s)
- Robert L Ross
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, PO Box 210172, Cincinnati, OH, 45221-0172, USA
| | | | - Patrick A Limbach
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, University of Cincinnati, PO Box 210172, Cincinnati, OH, 45221-0172, USA
| |
Collapse
|
13
|
Studzińska S, Mounicou S, Szpunar J, Łobiński R, Buszewski B. New approach to the determination phosphorothioate oligonucleotides by ultra high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry. Anal Chim Acta 2014; 855:13-20. [PMID: 25542085 DOI: 10.1016/j.aca.2014.12.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2014] [Revised: 12/03/2014] [Accepted: 12/04/2014] [Indexed: 01/27/2023]
Abstract
This text presents a novel method for the separation and detection of phosphorothioate oligonucleotides with the use of ion pair ultra high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry The research showed that hexafluoroisopropanol/triethylamine based mobile phases may be successfully used when liquid chromatography is coupled with such elemental detection. However, the concentration of both HFIP and TEA influences the final result. The lower concentration of HFIP, the lower the background in ICP-MS and the greater the sensitivity. The method applied for the analysis of serum samples was based on high resolution inductively coupled plasma mass spectrometry. Utilization of this method allows determination of fifty times lower quantity of phosphorothioate oligonucleotides than in the case of quadrupole mass analyzer. Monitoring of (31)P may be used to quantify these compounds at the level of 80 μg L(-1), while simultaneous determination of sulfur is very useful for qualitative analysis. Moreover, the results presented in this paper demonstrate the practical applicability of coupling LC with ICP-MS in determining phosphorothioate oligonucleotides and their metabolites in serum within 7 min with a very good sensitivity. The method was linear in the concentration range between 0.2 and 3 mg L(-1). The limit of detection was in the range of 0.07 and 0.13 mg L(-1). Accuracy varied with concentration, but was in the range of 3%.
Collapse
Affiliation(s)
- Sylwia Studzińska
- Chair of the Environmental Chemistry & Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University, 7 Gagarin St., PL-87 100 Torun, Poland.
| | - Sandra Mounicou
- CNRS/UPPA, Laboratoire de Chimie Analytique Bio-inorganique et Environnement, UMR 5254, Hélioparc, 2 av. Pr. Angot, F-64053 Pau, France
| | - Joanna Szpunar
- CNRS/UPPA, Laboratoire de Chimie Analytique Bio-inorganique et Environnement, UMR 5254, Hélioparc, 2 av. Pr. Angot, F-64053 Pau, France
| | - Ryszard Łobiński
- CNRS/UPPA, Laboratoire de Chimie Analytique Bio-inorganique et Environnement, UMR 5254, Hélioparc, 2 av. Pr. Angot, F-64053 Pau, France
| | - Bogusław Buszewski
- Chair of the Environmental Chemistry & Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University, 7 Gagarin St., PL-87 100 Torun, Poland
| |
Collapse
|
14
|
Johnson G, Ferrini A, Dolan SK, Nolan T, Agrawal S, Doyle S, Bustin SA. Biomarkers for invasive aspergillosis: the challenges continue. Biomark Med 2014; 8:429-51. [PMID: 24712434 DOI: 10.2217/bmm.13.129] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
The incidence of invasive aspergillosis (IA), an opportunistic infection in immunocompromised individuals, is rising, but its early diagnosis remains challenging and treatment options are limited. Hence there is an urgent need to improve existing diagnostic procedures as well as develop novel approaches. The clinical usefulness of galactomannan and β-d-glucan, widely used assays detecting cell-wall antigens of Aspergillus, is unclear and depends on clinicians' awareness of their practical limitations. This leaves room for new methods that utilise genomic, proteomic and metabolomics approaches as well as novel detection procedures, for example point-of-care lateral-flow devices. Each of these strategies has its own limitations and it is likely that a combination of methods will be required to achieve optimal performance for the diagnosis of IA and subsequent appropriate patient management.
Collapse
Affiliation(s)
- Gemma Johnson
- Blizard Institute, Queen Mary University of London, London, UK
| | | | | | | | | | | | | |
Collapse
|
15
|
Kullolli M, Knouf E, Arampatzidou M, Tewari M, Pitteri SJ. Intact microRNA analysis using high resolution mass spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2014; 25:80-87. [PMID: 24174127 PMCID: PMC4153431 DOI: 10.1007/s13361-013-0759-x] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2013] [Revised: 09/19/2013] [Accepted: 09/19/2013] [Indexed: 06/02/2023]
Abstract
MicroRNAs (miRNAs) are small single-stranded non-coding RNAs that post-transcriptionally regulate gene expression, and play key roles in the regulation of a variety of cellular processes and in disease. New tools to analyze miRNAs will add understanding of the physiological origins and biological functions of this class of molecules. In this study, we investigate the utility of high resolution mass spectrometry for the analysis of miRNAs through proof-of-concept experiments. We demonstrate the ability of mass spectrometry to resolve and separate miRNAs and corresponding 3' variants in mixtures. The mass accuracy of the monoisotopic deprotonated peaks from various miRNAs is in the low ppm range. We compare fragmentation of miRNA by collision-induced dissociation (CID) and by higher-energy collisional dissociation (HCD) which yields similar sequence coverage from both methods but additional fragmentation by HCD versus CID. We measure the linear dynamic range, limit of detection, and limit of quantitation of miRNA loaded onto a C18 column. Lastly, we explore the use of data-dependent acquisition of MS/MS spectra of miRNA during online LC-MS and demonstrate that multiple charge states can be fragmented, yielding nearly full sequence coverage of miRNA on a chromatographic time scale. We conclude that high resolution mass spectrometry allows the separation and measurement of miRNAs in mixtures and a standard LC-MS setup can be adapted for online analysis of these molecules.
Collapse
Affiliation(s)
- Majlinda Kullolli
- Canary Center for Cancer Early Detection, Department of Radiology, Stanford University School of Medicine, Palo Alto, CA, 94304, USA
| | | | | | | | | |
Collapse
|
16
|
Brahim B, Alves S, Cole RB, Tabet JC. Charge enhancement of single-stranded DNA in negative electrospray ionization using the supercharging reagent meta-nitrobenzyl alcohol. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2013; 24:1988-1996. [PMID: 24030289 DOI: 10.1007/s13361-013-0732-8] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2012] [Revised: 07/26/2013] [Accepted: 08/07/2013] [Indexed: 06/02/2023]
Abstract
Charge enhancement of single-stranded oligonucleotide ions in negative ESI mode is investigated. The employed reagent, meta-nitrobenzyl alcohol (m-NBA), was found to improve total signal intensity (Itot), increase the highest observed charge states (zhigh), and raise the average charge states (zavg) of all tested oligonucleotides analyzed in negative ESI. To quantify these increases, signal enhancement ratios (SER1%) and charge enhancement coefficients (CEC1%) were introduced. The SER1%, (defined as the quotient of total oligonucleotide ion abundances with 1% m-NBA divided by total oligonucleotide abundance without m-NBA) was found to be greater than unity for every oligonucleotide tested. The CEC1% values (defined as the average charge state in the presence of 1% m-NBA minus the average charge state in the absence of m-NBA) were found to be uniformly positive. Upon close inspection, the degree of charge enhancement for longer oligonucleotides was found to be dependent upon thymine density (i.e., the number and the location of phospho-thymidine units). A correlation between the charge enhancement induced by the presence of m-NBA and the apparent gas-phase acidity (largely determined by the sequence of thymine units but also by the presence of protons on other nucleobases) of multiply deprotonated oligonucleotide species, was thus established. Ammonium cations appeared to be directly involved in the m-NBA supercharging mechanism, and their role seems to be consistent with previously postulated ESI mechanisms describing desorption/ionization of single-stranded DNA into the gas phase.
Collapse
Affiliation(s)
- Bessem Brahim
- Institut Parisien de Chimie Moléculaire, Equipe de Chimie Structurale Organique et Biologique, Université Pierre et Marie Curie, CNRS UMR 7201, 75252, Paris cedex 05, France
| | | | | | | |
Collapse
|
17
|
Abstract
A method of analysis is presented that utilizes matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) to monitor the kinetics and products of RNA cleavage, by use of a program designed to mass-match observed MS peaks with predicted RNA cleavage products. The method is illustrated through application to the study of targeted oxidation of RNA stem loops from HIV-1 Rev Response Element mRNA (RRE RNA) and ribosomal 16S A-site RNA (16S RNA) by metallonucleases. Following incubation of each RNA with catalysts and/or redox co-reactants, reaction mixtures were desalted, and MALDI-TOF MS was used to monitor both time-resolved formation of cleavage products and disappearance of full-length RNA. For each RNA, a unique list was generated that contained the predicted masses of both the full-length, and all of the possible RNA cleavage fragments that resulted from the combination of all possible cleavage sites and each of the six expected overhangs formed at nascent termini adjacent to the cleavage sites. The overhangs corresponded to 2′,3′-cyclic phosphate, 3′-phosphate, 3′-phosphoglycolate, 5′- hydroxyl and 5′- phosphate, which corresponded to differing oxidative, hydrolytic, and/or 2′-OH-mediated-endonucleolytic modes of scission. Each mass spectrum was compared with a corresponding list of predicted masses, and peaks were rapidly assigned by use of a Perl script, with a mass-matching tolerance of 200 ppm. Both time-dependent cleavage mediated by metallonucleases and MALDI-TOF-induced fragmentation were observed, and these were distinguished by time-dependent experiments. The resulting data allowed a semi-quantitative assessment of the rate of formation of each overhang at each nucleotide position. Limitations included artifactual skewing of quantification by mass bias, a limited mass range for quantification, and a lack of detection of secondary cleavage products. Nevertheless, the method presented herein provides a rapid, accurate, highly-detailed and semi-quantitative analysis of RNA cleavage that should be widely applicable.
Collapse
Affiliation(s)
- Jeff C Joyner
- Department of Chemistry and Biochemistry, Evans Laboratory of Chemistry, The Ohio State University, Columbus, OH 43210, USA
| | | | | |
Collapse
|
18
|
Beverly MB. Applications of mass spectrometry to the study of siRNA. MASS SPECTROMETRY REVIEWS 2011; 30:979-998. [PMID: 20201110 DOI: 10.1002/mas.20260] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2008] [Revised: 08/13/2009] [Accepted: 08/13/2009] [Indexed: 05/28/2023]
Abstract
RNA interference (RNAi) has quickly become a well-established laboratory tool for regulating gene expression and is currently being explored for its therapeutic potential. The design and use of double-stranded RNA oligonucleotides as therapeutics to trigger the RNAi mechanism and a greater effort to understand the RNAi pathway itself is driving the development of analytical techniques that can characterize these oligonucleotides. Electrospray (ESI) and MALDI have been used routinely to analyze oligonucleotides and their ability to provide mass and sequence information has made them ideal for this application. Reviewed here is the work done to date on the use of ESI and MALDI for the study of RNAi oligonucleotides as well as the strategies and issues associated with siRNA analysis by mass spectrometry. While there is not a large body of literature on the specific application of mass spectrometry to RNAi, the work done in this area is a good demonstration of the range of experiments that can be conducted and the value that ESI and MALDI can provide to the RNAi field.
Collapse
Affiliation(s)
- Michael B Beverly
- RNA Therapeutics Department, Merck and Co., Inc., Boulder, CO 80301, USA.
| |
Collapse
|
19
|
Castleberry CM, Limbach PA. Relative quantitation of transfer RNAs using liquid chromatography mass spectrometry and signature digestion products. Nucleic Acids Res 2010; 38:e162. [PMID: 20587503 PMCID: PMC2938229 DOI: 10.1093/nar/gkq578] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Transfer ribonucleic acids (tRNAs) are challenging to identify and quantify from unseparated mixtures. Our lab previously developed the signature digestion approach for identifying tRNAs without specific separation. Here we describe the combination of relative quantification via enzyme-mediated isotope labeling with this signature digestion approach for the relative quantification of tRNAs. These quantitative signature digestion products were characterized using liquid chromatography mass spectrometry (LC-MS), and we find that up to 5-fold changes in tRNA abundance can be quantified from sub-microgram amounts of total tRNA. Quantitative tRNA signature digestion products must (i) incorporate an isotopic label during enzymatic digestion; (ii) have no m/z interferences from other signature digestion products in the sample and (iii) yield a linear response during LC-MS analysis. Under these experimental conditions, the RNase T1, A and U2 signature digestion products that potentially could be used for the relative quantification of Escherichia coli tRNAs were identified, and the linearity and sequence identify of RNase T1 signature digestion products were experimentally confirmed. These RNase T1 quantitative signature digestion products were then used in proof-of-principle experiments to quantify changes arising due to different culturing media to 17 tRNA families. This method enables new experiments where information regarding tRNA identity and changes in abundance are desired.
Collapse
Affiliation(s)
- Colette M Castleberry
- Rieveschl Laboratories for Mass Spectrometry, Department of Chemistry, PO Box 210172, University of Cincinnati, Cincinnati, OH 45221-0172, USA
| | | |
Collapse
|
20
|
Taucher M, Rieder U, Breuker K. Minimizing base loss and internal fragmentation in collisionally activated dissociation of multiply deprotonated RNA. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2010; 21:278-85. [PMID: 19932627 DOI: 10.1016/j.jasms.2009.10.010] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2009] [Revised: 09/28/2009] [Accepted: 10/14/2009] [Indexed: 05/25/2023]
Abstract
In recent years, new classes of nonprotein-coding ribonucleic acids (ncRNAs) with important cellular functions have been discovered. Of particular interest for biomolecular research and pharmaceutical developments are small ncRNAs that are involved in gene regulation, such as small interfering RNAs (21-28 nt), pre-microRNAs (70-80 nt), or riboswitches (34-200 nt). De novo sequencing of RNA by top-down mass spectrometry has so far been limited to RNA consisting of up to approximately 20 nt. We report here complete sequence coverage for 34 nt RNA (10.9 kDa), along with 30 out of 32 possible complementary ion pairs from collisionally activated dissociation (CAD) experiments. The key to minimizing undesired base loss and internal fragmentation is to minimize the internal energy of fragment ions from primary backbone cleavage. This can be achieved by collisional cooling of primary fragment ions and selection of precursor ions of relatively low negative net charge (about -0.2/nt).
Collapse
Affiliation(s)
- Monika Taucher
- Institute of Organic Chemistry and Center for Molecular Biosciences, University of Innsbruck, Innsbruck, Austria
| | | | | |
Collapse
|
21
|
Fabris D. A role for the MS analysis of nucleic acids in the post-genomics age. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2010; 21:1-13. [PMID: 19897384 DOI: 10.1016/j.jasms.2009.09.006] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2009] [Revised: 09/04/2009] [Accepted: 09/04/2009] [Indexed: 05/28/2023]
Abstract
The advances of mass spectrometry in the analysis of nucleic acids have tracked very closely the exciting developments of instrumentation and ancillary technologies, which have taken place over the years. However, their diffusion in the broader life sciences community has been and will be linked to the ever evolving focus of biomedical research and its changing demands. Before the completion of the Human Genome Project, great emphasis was placed on sequencing technologies that could help accomplish this project of exceptional scale. After the publication of the human genome, the emphasis switched toward techniques dedicated to the exploration of sequences not coding for actual protein products, which amount to the vast majority of transcribed elements. The broad range of capabilities offered by mass spectrometry is rapidly advancing this platform to the forefront of the technologies employed for the structure-function investigation of these noncoding elements. Increasing focus on the characterization of functional assemblies and their specific interactions has prompted a re-evaluation of what has been traditionally construed as nucleic acid analysis by mass spectrometry. Inspired by the accelerating expansion of the broader field of nucleic acid research, new applications to fundamental biological studies and drug discovery will help redefine the evolving role of MS-analysis of nucleic acids in the post-genomics age.
Collapse
Affiliation(s)
- Daniele Fabris
- Department of Chemistry and Biochemistry, University of Maryland Baltimore County, Baltimore, Maryland 21228, USA.
| |
Collapse
|
22
|
Ditzler MA, Rueda D, Mo J, Håkansson K, Walter NG. A rugged free energy landscape separates multiple functional RNA folds throughout denaturation. Nucleic Acids Res 2008; 36:7088-99. [PMID: 18988629 PMCID: PMC2602785 DOI: 10.1093/nar/gkn871] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
The dynamic mechanisms by which RNAs acquire biologically functional structures are of increasing importance to the rapidly expanding fields of RNA therapeutics and biotechnology. Large energy barriers separating misfolded and functional states arising from alternate base pairing are a well-appreciated characteristic of RNA. In contrast, it is typically assumed that functionally folded RNA occupies a single native basin of attraction that is free of deeply dividing energy barriers (ergodic hypothesis). This assumption is widely used as an implicit basis to interpret experimental ensemble-averaged data. Here, we develop an experimental approach to isolate persistent sub-populations of a small RNA enzyme and show by single molecule fluorescence resonance energy transfer (smFRET), biochemical probing and high-resolution mass spectrometry that commitment to one of several catalytically active folds occurs unexpectedly high on the RNA folding energy landscape, resulting in partially irreversible folding. Our experiments reveal the retention of molecular heterogeneity following the complete loss of all native secondary and tertiary structure. Our results demonstrate a surprising longevity of molecular heterogeneity and advance our current understanding beyond that of non-functional misfolds of RNA kinetically trapped on a rugged folding-free energy landscape.
Collapse
Affiliation(s)
- Mark A Ditzler
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA
| | | | | | | | | |
Collapse
|
23
|
Bujnicki JM, Droogmans L, Grosjean H, Purushothaman SK, Lapeyre B. Bioinformatics-Guided Identification and Experimental Characterization of Novel RNA Methyltransferas. ACTA ACUST UNITED AC 2008. [DOI: 10.1007/978-3-540-74268-5_7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/28/2023]
|
24
|
Dai Q, Fong R, Saikia M, Stephenson D, Yu YT, Pan T, Piccirilli JA. Identification of recognition residues for ligation-based detection and quantitation of pseudouridine and N6-methyladenosine. Nucleic Acids Res 2007; 35:6322-9. [PMID: 17881375 PMCID: PMC2094055 DOI: 10.1093/nar/gkm657] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
Over 100 chemical types of RNA modifications have been identified in thousands of sites in all three domains of life. Recent data suggest that modifications function synergistically to mediate biological function, and that cells may coordinately modulate modification levels for regulatory purposes. However, this area of RNA biology remains largely unexplored due to the lack of robust, high-throughput methods to quantify the extent of modification at specific sites. Recently, we developed a facile enzymatic ligation-based method for detection and quantitation of methylated 2′-hydroxyl groups within RNA. Here we exploit the principles of molecular recognition and nucleic acid chemistry to establish the experimental parameters for ligation-based detection and quantitation of pseudouridine (Ψ) and N6-methyladenosine (m6A), two abundant modifications in eukaryotic rRNA/tRNA and mRNA, respectively. Detection of pseudouridylation at several sites in the large subunit rRNA derived from yeast demonstrates the feasibility of the approach for analysis of pseudouridylation in biological RNA samples.
Collapse
Affiliation(s)
- Qing Dai
- Department of Biochemistry and Molecular Biology, Howard Hughes Medical Institute, University of Chicago, Chicago, IL 60637, Department of Chemistry and Department of Biochemistry and Biophysics, University of Rochester Medical Center, Rochester, NY 14642, USA
| | - Robert Fong
- Department of Biochemistry and Molecular Biology, Howard Hughes Medical Institute, University of Chicago, Chicago, IL 60637, Department of Chemistry and Department of Biochemistry and Biophysics, University of Rochester Medical Center, Rochester, NY 14642, USA
| | - Mridusmita Saikia
- Department of Biochemistry and Molecular Biology, Howard Hughes Medical Institute, University of Chicago, Chicago, IL 60637, Department of Chemistry and Department of Biochemistry and Biophysics, University of Rochester Medical Center, Rochester, NY 14642, USA
| | - David Stephenson
- Department of Biochemistry and Molecular Biology, Howard Hughes Medical Institute, University of Chicago, Chicago, IL 60637, Department of Chemistry and Department of Biochemistry and Biophysics, University of Rochester Medical Center, Rochester, NY 14642, USA
| | - Yi-tao Yu
- Department of Biochemistry and Molecular Biology, Howard Hughes Medical Institute, University of Chicago, Chicago, IL 60637, Department of Chemistry and Department of Biochemistry and Biophysics, University of Rochester Medical Center, Rochester, NY 14642, USA
| | - Tao Pan
- Department of Biochemistry and Molecular Biology, Howard Hughes Medical Institute, University of Chicago, Chicago, IL 60637, Department of Chemistry and Department of Biochemistry and Biophysics, University of Rochester Medical Center, Rochester, NY 14642, USA
| | - Joseph A. Piccirilli
- Department of Biochemistry and Molecular Biology, Howard Hughes Medical Institute, University of Chicago, Chicago, IL 60637, Department of Chemistry and Department of Biochemistry and Biophysics, University of Rochester Medical Center, Rochester, NY 14642, USA
- *To whom correspondence should be addressed. +1 773 702 9312+1 773 702 0271 Correspondence may also be addressed to Tao Pan. +1 773 702 4179+1 773 702 0439; E-mail:
| |
Collapse
|
25
|
Turner KB, Hagan NA, Kohlway AS, Fabris D. Mapping noncovalent ligand binding to stemloop domains of the HIV-1 packaging signal by tandem mass spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2006; 17:1402-1411. [PMID: 16872834 DOI: 10.1016/j.jasms.2006.06.009] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2006] [Revised: 05/29/2006] [Accepted: 06/06/2006] [Indexed: 05/11/2023]
Abstract
The binding modes and structural determinants of the noncovalent complexes formed by aminoglycoside antibiotics with conserved domains of the HIV-1 packaging signal (Psi-RNA) were investigated using electrospray ionization (ESI) Fourier transform mass spectrometry (FTMS). The location of the aminoglycoside binding sites on the different stemloop structures was revealed by characteristic coverage gaps in the ion series obtained by sustained off-resonance irradiation collision induced dissociation (SORI-CID) of the antibiotic-RNA assemblies. The site positions were confirmed using mutants that eliminated salient structural features of the Psi-RNA domains. The effects of the mutations on the binding properties of the different substrates served to validate the position of the aminoglycoside site on the wild-type structures. Additional information was provided by docking experiments performed on the different aminoglycoside-stemloop complexes. The results have shown that, in the absence of features disrupting the regular A-helix of the double-stranded stem, aminoglycosides tend to bind in an area situated between the upper stem and the loop regions, as demonstrated for stemloop SL3. The presence of a tandem wobbles motif in SL4 modifies the regular geometry of the upper stem, which does not affect the general site location, but greatly increases its solution binding affinity compared with SL3. The platform motif in SL2 locates the binding site in the stem midsection and confers upon this stemloop an intermediate affinity toward aminoglycosides. In SL3 and SL4, the extensive overlap of the antibiotic site with the region used to bind the nucleocapsid (NC) protein provides the basis for a competition mechanism that could explain the aminoglycoside inhibition of the NC.SL3 and NC.SL4 assemblies. In contrast, the minimal overlap between the aminoglycoside and the NC sites in SL2 accounts for the absence of inhibition of the NC.SL2 complex.
Collapse
Affiliation(s)
- Kevin B Turner
- Department of Chemistry and Biochemistry, University of Maryland Baltimore County, 100 Hilltop Circle, 21228, Baltimore, MD, USA
| | - Nathan A Hagan
- Department of Chemistry and Biochemistry, University of Maryland Baltimore County, 100 Hilltop Circle, 21228, Baltimore, MD, USA
| | - Andrew S Kohlway
- Department of Chemistry and Biochemistry, University of Maryland Baltimore County, 100 Hilltop Circle, 21228, Baltimore, MD, USA
| | - Daniele Fabris
- Department of Chemistry and Biochemistry, University of Maryland Baltimore County, 100 Hilltop Circle, 21228, Baltimore, MD, USA.
| |
Collapse
|
26
|
Chen WY, Chen YC. Reducing the alkali cation adductions of oligonucleotides using sol-gel-assisted laser desorption/ionization mass spectrometry. Anal Chem 2004; 75:4223-8. [PMID: 14632139 DOI: 10.1021/ac0300439] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The alkali cation adductions of oligonucleotides dramatically degrade MALDI mass spectra and even affect the detection limit. Desalting is generally involved in MALDI sample preparation. This work demonstrates the feasibility of using 3,4-diaminobenzoic acid (DABA) and 3,5-DABA as the MALDI matrix for oligonucleotide analysis. Furthermore, sodium ion adducts of oligonucleotides were simultaneously reduced in the mass spectra when DABA was used as the MALDI matrix and sol-gel material was used as the sample support. However, depositing the sample on the sample support was very difficult, and the lack of homogeneity of analytes/matrix distribution on the sample support also led the analyte signals to be revealed only in "sweet spots". Alternatively, DABA was doped into sol-gel materials to generate homogeneous DABA/sol-gel hybrid film. The DABA/sol-gel hybrid film was used as the sample substrate to assist the desorption/ ionization of analytes. The analyte signals were evenly found on the sample substrate. The sodium ion adductions of oligonucleotides were also effectively suppressed. The sample preparation used in this approach resembles that used in the authors' previous study, involving sol-gel-assisted laser desorption/ionization (SGALDI) mass spectrometry (Lin, Y.-S.; Chen, Y.-C. Anal Chem. 2002, 74, 5793-5798.) The SGALDI approach was demonstrated to be effective in assisting the desorption/ionization of peptides and small proteins. Herein, the SGALDI material, DABA/sol-gel hybrid material, was successfully applied to oligonucleotide analysis, and good-quality mass spectra were obtained without extra desalting. Additionally, the presence of 0.1% SDS in the oligonucleotide sample solution was tolerated without degrading the mass spectra. The largest detectable molecular size for oligonucleotides was 72 mer. The detection limit for 24 mer of oligonucleotide was 20 fmol.
Collapse
Affiliation(s)
- Wei-Yu Chen
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu 300, Taiwan
| | | |
Collapse
|
27
|
Null AP, Benson LM, Muddiman DC. Enzymatic strategies for the characterization of nucleic acids by electrospray ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2003; 17:2699-2706. [PMID: 14673816 DOI: 10.1002/rcm.1255] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Electrospray ionization mass spectrometry (ESI-MS) is a powerful technique used for the identification and characterization of DNA polymorphisms. Continual improvement in instrument design assures high mass measurement accuracy, sensitivity, and resolving power. This work describes an eclectic array of enzymatic strategies we have invoked in order to detect single-nucleotide polymorphisms by ESI-MS, although other applications may be envisioned. One strategy combines the use of two enzymes, exonuclease III and lambda exonuclease, to provide a ladder of single-stranded DNA fragments for straightforward sequence identification by mass spectrometry. A second strategy combines restriction enzymes to screen for polymorphisms present within specific amplicons. Finally, we describe the use of stable-isotope-labeled nucleotides for the determination of length and base composition of a PCR product.
Collapse
Affiliation(s)
- Allison P Null
- W. M. Keck FT-ICR Mass Spectrometry Laboratory, Mayo Proteomics Research Center, and Department of Biochemistry and Molecular Biology, Mayo Clinic College of Medicine, Rochester, MN 55905, USA
| | | | | |
Collapse
|
28
|
Petković M, Müller J, Müller M, Schiller J, Arnold K, Arnhold J. Application of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for monitoring the digestion of phosphatidylcholine by pancreatic phospholipase A(2). Anal Biochem 2002; 308:61-70. [PMID: 12234464 DOI: 10.1016/s0003-2697(02)00236-1] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Different methods were established for monitoring the phospholipase A(2)(PLA(2)) activity but all of them are rather cumbersome and time consuming. In this paper we have investigated the suitability of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) for the determination of the PLA(2) activity. Phosphatidylcholine (PC) was digested with pancreatic PLA(2) under different conditions, i.e., various Ca(2+), PC, and PLA(2) concentrations. The digestion products were analyzed by MALDI-TOF MS and the concentration of lysophosphatidylcholine (LPC)-generated upon PLA(2) digestion-was determined by the application of an internal standard (known concentration) and by a comparison of their signal-to-noise ratios. The results clearly demonstrate that the LPC concentration determined from the MALDI-TOF mass spectra correlates directly with the activity of the applied enzyme. Additionally, LPC concentration increased with an increase in Ca(2+), as well as in the PC concentration. A single MALDI-TOF mass spectrum provides immediate information on the digestion products as well as on the residual substrate without requirements for any previous derivatization. MALDI-TOF MS can be easily and simply applied for monitoring the PLA(2) activity and we assume that this method might also be useful for other types of phospholipases.
Collapse
Affiliation(s)
- Marijana Petković
- Institute of Medical Physics and Biophysics, Medical Faculty, University of Leipzig, Germany.
| | | | | | | | | | | |
Collapse
|
29
|
Rozenski J, McCloskey JA. SOS: a simple interactive program for ab initio oligonucleotide sequencing by mass spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2002; 13:200-203. [PMID: 11908799 DOI: 10.1016/s1044-0305(01)00354-3] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Mass spectra of oligonucleotides derived from collision-induced dissociation following electrospray ionization provide an effective means of sequence determination, at the 20-mer level and below. An interactive, stand-alone computer program, Simple Oligonucleotide Sequencer (SOS) has been developed for rapid oligonucleotide sequencing from mass spectra, under user control on a residue by residue basis. Modifications can be defined in any combination for the base, sugar or backbone. Sequence ladders can be independently constructed in both the 5' --> 3' directions and 3' --> 5' directions, and graphically compared for homology and overlap. A particular advantage of this method is the ability to easily erase and rebuild alternate subsequences. The program can be used for ab initio sequencing of modified or unmodified oligonucleotides, for rapid verification of sequence, and in studies of fragmentation processes of model oligonucleotide derivatives.
Collapse
Affiliation(s)
- Jef Rozenski
- Rega Institute for Medical Research, Katholieke Universiteit Leuven, Belgium.
| | | |
Collapse
|
30
|
Alazard D, Filipowsky M, Raeside J, Clarke M, Majlessi M, Russell J, Weisburg W. Sequencing of production-scale synthetic oligonucleotides by enriching for coupling failures using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Anal Biochem 2002; 301:57-64. [PMID: 11811967 DOI: 10.1006/abio.2001.5493] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A technique for sequencing oligonucleotides using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry is described. The series of coupling failure species are extracted from the dimethoxytrityl-on, full-length oligonucleotide in crude synthetic material using C18 stationary-phase cartridges. These concentrated failure species can be easily detected by MALDI-TOF, which determines the mass difference between spectral ions to identify a particular base. The solid-phase extraction step greatly enhances ion signals and mass resolution, and sequencing information is generally obtained from the 5' end up to the first three to four nucleotides at the 3' end. Complete sequence can be generated in conjunction with snake venom phosphodiesterase digestion of purified material. This method eliminates difficulties associated with other mass spectrometric sequencing techniques involving oligonucleotide length; structure; and sugar, base, and backbone modifications. Examples of sequencing a 17-mer composed primarily of 2'-O-methylribonucleotides and a single nonnucleosidic linker and a mixed sugar backbone 51-mer with 2'-O-methylribonucleotides and a homopolymer tail are reported in this study.
Collapse
Affiliation(s)
- David Alazard
- Gen-Probe Incorporated, 10210 Genetic Center Drive, San Diego, California 92121-4362, USA.
| | | | | | | | | | | | | |
Collapse
|
31
|
Bigwarfe PM, White TP, Wood TD. Polyaniline-coated nanoelectrospray emitters: performance characteristics in the negative ion mode. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2002; 16:2266-2272. [PMID: 12478570 DOI: 10.1002/rcm.854] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The increasing tendency to miniaturize analytical techniques has resulted in the widespread use of nanoelectrospray ionization mass spectrometry. A new polyaniline-coated nanoelectrospray emitter has shown increasing promise as a more durable and stable alternative to traditional metal-coated emitters. In this report, the utility of polyaniline-coated nanoelectrospray emitters in the negative ion mode is investigated. Here, oligonucleotides and peptides have been ionized in the negative mode using polyaniline-coated nanoelectrospray emitters. The emitters were found to be durable for at least an hour in the negative ion mode, during which time the signal was stable. The high amount of electrical discharge usually associated with negative ion mode nanoelectrospray was not problematic with the polyaniline-coated emitters. These characteristics make possible the reliable coupling of low-flow separations to negative ion nanoelectrospray without the worry of emitter failure during the course of the experiment.
Collapse
Affiliation(s)
- Paul M Bigwarfe
- Department of Chemistry, Natural Sciences Complex, University at Buffalo, The State University of New York, Buffalo, NY 14260-3000, USA
| | | | | |
Collapse
|
32
|
Patteson KG, Rodicio LP, Limbach PA. Identification of the mass-silent post-transcriptionally modified nucleoside pseudouridine in RNA by matrix-assisted laser desorption/ionization mass spectrometry. Nucleic Acids Res 2001; 29:E49-9. [PMID: 11353094 PMCID: PMC55470 DOI: 10.1093/nar/29.10.e49] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2001] [Revised: 02/23/2001] [Accepted: 03/08/2001] [Indexed: 11/13/2022] Open
Abstract
A new method using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for the direct analysis of the mass-silent post-transcriptionally modified nucleoside pseudouridine in nucleic acids has been developed. This method utilizes 1-cyclohexyl-3-(2-morpholinoethyl)carbodiimide to derivatize pseudouridine residues. After chemical derivatization all pseudouridine residues will contain a 252 Da 'mass tag' that allows the presence of pseudouridine to be identified using mass spectrometry. Pseudouridine residues can be identified in intact nucleic acids by obtaining a mass spectrum of the nucleic acid before and after derivatization. The mass difference (in units of 252 Da) will denote the number of pseudouridine residues present. To determine the sequence location of pseudouridine, a combination of enzymatic hydrolysis and mass spectrometric steps are used. Here, MALDI analysis of RNase T1 digestion products before and after modification are used to narrow the sequence location of pseudouridine to specific T1 fragments in the gene sequence. Further mass spectrometric monitoring of exonuclease digestion products from isolated T1 fragments is then used for exact sequence placement. This approach to pseudouridine identification is demonstrated using Escherichia coli tRNAS: This new method allows for the direct determination of pseudouridine in nucleic acids, can be used to identify modified pseudouridine residues and can be used with general modification mapping approaches to completely characterize the post-transcriptional modifications present in RNAs.
Collapse
MESH Headings
- Base Sequence
- CME-Carbodiimide/analogs & derivatives
- CME-Carbodiimide/metabolism
- Chromatography, High Pressure Liquid
- Escherichia coli/genetics
- Molecular Weight
- Pseudouridine/analysis
- Pseudouridine/genetics
- Pseudouridine/metabolism
- RNA Processing, Post-Transcriptional
- RNA, Bacterial/chemistry
- RNA, Bacterial/genetics
- RNA, Bacterial/metabolism
- RNA, Transfer, Phe/chemistry
- RNA, Transfer, Phe/genetics
- RNA, Transfer, Phe/metabolism
- RNA, Transfer, Val/chemistry
- RNA, Transfer, Val/genetics
- RNA, Transfer, Val/metabolism
- Ribonuclease T1/metabolism
- Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods
Collapse
Affiliation(s)
- K G Patteson
- 232 Choppin Hall, Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA
| | | | | |
Collapse
|
33
|
Beck JL, Colgrave ML, Ralph SF, Sheil MM. Electrospray ionization mass spectrometry of oligonucleotide complexes with drugs, metals, and proteins. MASS SPECTROMETRY REVIEWS 2001; 20:61-87. [PMID: 11455562 DOI: 10.1002/mas.1003] [Citation(s) in RCA: 167] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
I. Introduction 61 II. Binding of Small Molecules to DNA 62 A. Covalent Binding 62 B. Reversible (Noncovalent) DNA-Binding Agents 65 III. DNA-Metal Ion Complexes 67 A. Platinum Complexes 70 B. Other Metal Ions 73 IV. DNA-Protein Complexes 74 A. Introduction 74 B. ESI-MS of DNA-Protein Complexes 76 C. ESI-MS Analysis of Proteolytic Products of DNA-Protein Complexes 79 D. ESI-MS of Ternary DNA-Protein-Ligand Complexes 80 V. Conclusions 80 Abbreviations 81 References 81 --Interactions of DNA with drugs, metal ions, and proteins are important in a wide variety of biological processes. With the advent of electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI), mass spectrometry (MS) is now a well-established tool for the characterization of the primary structures of biopolymers. The gentle nature of the ESI process, however, means that ESI-MS is also finding application for the study of noncovalent and other fragile biomolecular complexes. We outline here the progress, to date, in the use of ESI-MS for the study of noncovalent drug-DNA and protein-DNA complexes together with strategies that can be employed to examine the binding of small molecules and metal complexes to DNA. In the case of covalent complexes with DNA, sequence information can be derived from ESI-MS used in conjunction with tandem mass spectrometry (MS/MS) and/or enzymatic digestion. MS/MS can also be used to probe the relative binding affinities of drugs that bind to DNA via noncovalent interactions. Overall, the work in this area, to date has demonstrated that ESI-MS and MS/MS will prove to be valuable complements to other structural methods, offering advantages in terms of speed, specificity, and sensitivity. (c) 2001 John Wiley & Sons, Inc.
Collapse
Affiliation(s)
- J L Beck
- Department of Chemistry, University of Wollongong, New South Wales 2522, Australia
| | | | | | | |
Collapse
|
34
|
Petkovic M, Schiller J, Müller M, Benard S, Reichl S, Arnold K, Arnhold J. Detection of individual phospholipids in lipid mixtures by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry: phosphatidylcholine prevents the detection of further species. Anal Biochem 2001; 289:202-16. [PMID: 11161314 DOI: 10.1006/abio.2000.4926] [Citation(s) in RCA: 228] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry is an established tool for the analysis of proteins, whereas it gained by far less interest in the field of lipid analysis. This method works well with phospholipids as well as organic cell extracts and provides high sensitivity and reproducibility. The aim of the present paper is to extend our previous studies to the analysis of lysophospholipids and phospholipid mixtures. To study the suitability of MALDI-TOF mass spectrometry for the analysis of lysophospholipids, different phospholipids like phosphatidylcholine, phosphatidylethanolamine, phosphatidylserine, phosphatidic acid, and phosphatidylinositol as well as their mixtures were digested with phospholipase A(2). Positive and negative ion mass spectra of all phospholipids before and after digestion were recorded. In all these cases, the molecular ions of the expected digestion products could be detected and only a very small extent of further fragmentation was observed. On the other hand, spectra of phospholipid mixtures containing phosphatidylcholine were strongly dominated by phosphatidylcholine and lysophosphatidylcholine signals, which prevented the detection of further phospholipids even if those lipids were present in comparable amounts. This is of paramount interest for the analysis of tissue and cell extracts.
Collapse
Affiliation(s)
- M Petkovic
- Institute of Medical Physics and Biophysics, Medical Faculty, University of Leipzig, Liebigstrasse 27, D-04103 Leipzig, Germany.
| | | | | | | | | | | | | |
Collapse
|
35
|
Affiliation(s)
- D H Chace
- Division of Bio-Analytical Chemistry and Mass Spectrometry, Neo Gen Screening, Inc., P.O. Box 219, Bridgeville, Pennsylvania 15017, USA.
| |
Collapse
|
36
|
Dickman M, Hornby DP. Isolation of single-stranded DNA using denaturing DNA chromatography. Anal Biochem 2000; 284:164-7. [PMID: 10933872 DOI: 10.1006/abio.2000.4669] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Affiliation(s)
- M Dickman
- Transgenomic Research Laboratory, Krebs Institute, University of Sheffield, Western Bank, Sheffield, S10 2TN United Kingdom
| | | |
Collapse
|
37
|
Fourier transform ion cyclotron resonance mass spectrometry as a high throughput affinity screen to identify RNA binding ligands. Trends Analyt Chem 2000. [DOI: 10.1016/s0165-9936(00)00029-7] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
38
|
Vachet RW, Callahan JH. Quadrupole ion trap studies of the structure and reactivity of transition metal ion pair complexes. JOURNAL OF MASS SPECTROMETRY : JMS 2000; 35:311-320. [PMID: 10767759 DOI: 10.1002/(sici)1096-9888(200003)35:3<311::aid-jms918>3.0.co;2-6] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Ion pairs are common species observed in the electrospray mass spectra of transition metal coordination complexes. To understand the nature of these ion pairs, a systematic study of the gas-phase chemistry of these species using ion-molecule reactions and collision-induced dissociation (CID) was carried out. Ion pair complexes of the type MLnX+ (where M is Mn(II), Fe(II), Co(II), Ni(II), Cu(II) or Zn(II), L is 1,10-phenanthroline, 2,2'-bipyridine, ethylenediamine, diethylenetriamine or 1,4,8,11-tetraazacyclotetradecane and X is Cl-, NO3-, acetylacetonate, ClO4-, acetate or SCN-) were studied. Ion-molecule reactions can distinguish whether the counterion in an ion pair is an inner- or outer-sphere ligand and can determine the coordination mode of the counterion. In addition, CID and ion-molecule reactions reveal some interesting chemistry of these complexes and unique coordination modes for some of the anions studied here were inferred from the ion-molecule reactions. For example, the thiocyanate ion is found to coordinate in a bidentate fashion in Zn(II) and Ni(II) complexes, contrasting behavior typically observed in solution. Also, certain Co(II) and Fe(II) ion pair complexes undergo oxidation reactions in which species such as dioxygen and nitric oxide from the counterions ClO4- and NO3- are transferred to the Co(II) and Fe(II) complexes, showing the inherent affinity of these metals for these molecules. These complexes were also studied by ion-molecule reactions and CID. Dioxygen in complexes formed by CID is demonstrated to be bidentate, suggesting the formation of a peroxo ligand with concurrent oxidation of the metal.
Collapse
Affiliation(s)
- RW Vachet
- Chemistry Division, Naval Research Laboratory, Washington, DC 20375, USA
| | | |
Collapse
|
39
|
Walk TB, Süssmuth R, Kempter C, Gnau V, Jack RW, Jung G. Identification of unusual amino acids in peptides using automated sequential Edman degradation coupled to direct detection by electrospray-ionization mass spectrometry. Biopolymers 1999; 49:329-40. [PMID: 10079771 DOI: 10.1002/(sici)1097-0282(19990405)49:4<329::aid-bip7>3.0.co;2-f] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The determination of the primary structure of peptides and proteins is routine in many laboratories; however, many of the obtained sequences are incomplete or can be misinterpreted when the samples contain unusual amino acids. Here we report the development of an automated peptide sequenator coupled to an electrospray-ionization (ESI) mass spectrometer (MS) that, in conjunction with minor modifications to the sequencing conditions and, in some cases, prior derivatization of amino acids, allows the detection of the phenylthiohydantoin (PTH) derivatives of a number of unusual amino acids. Using the coupled sequenator-ESI-MS system we were able to determine the complete sequence of the lantibiotic gallidermin, a partial sequence of the calcium-dependent peptide antibiotic CDA2 as well as the pool sequence of a mixture of synthetic peptides containing nonproteinogenic amino acids. In addition to the 20 proteinogenic amino acids, the procedure was able to detect PTH derivatives of hydroxyphenylglycine, 2,3-didehydroasparagine, 3-methylglutamic acid, oxytryptophan, ornithine, N-methylglycine, dihydroxyphenylalanine, and alpha-aminoisobutyric acid. Similarly, after a simple derivatization procedure, we were also able to correctly identify educts of 2,3-didehydroalanine, 2,3-didehydrobutyrine, lanthionine, and 3-methyllanthionine.
Collapse
Affiliation(s)
- T B Walk
- Institut für Organische Chemie der Universität Tübingen, Germany
| | | | | | | | | | | |
Collapse
|
40
|
Ni J, Liu T, Kolbanovskiy A, Krzeminski J, Amin S, Geacintov NE. Mass spectrometric sequencing of site-specific carcinogen-modified oligodeoxyribonucleotides containing bulky benzo[a]pyrene diol epoxide-deoxyguanosyl adducts. Anal Biochem 1998; 264:222-9. [PMID: 9866687 DOI: 10.1006/abio.1998.2835] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Site-specific carcinogen-modified oligonucleotides are often used in site-directed mutagenesis and other biological and biochemical studies of structure-function relationships. Postsynthetic analysis and confirmation of the sites of carcinogen binding in such oligonucleotides is an important step in the characterization of these site-specific carcinogen-DNA adducts. It is shown here that negative ion mode electrospray tandem mass spectrometry methods and collision-induced dissociation offer a rapid and convenient approach for the sequencing of products derived from the reaction of the carcinogenic and mutagenic metabolite of benzo[a]pyrene, the diol epoxide r7,t8-dihydroxy-t9,10-epoxy-7,8,9,10-tetrahydrobenzo[a]pyrene (anti-BPDE), with the 11-mer oligonucleotide d(CATGCGGCCTAC). The site of reaction of anti-BPDE with either one of the three dG residues in this oligonucleotide can be accurately established by comparing the mass/charge ratios of the observed collision-induced dissociation fragments with calculated values.
Collapse
Affiliation(s)
- J Ni
- American Health Foundation, Valhalla, New York 10595, USA
| | | | | | | | | | | |
Collapse
|
41
|
Hurst GB, Weaver K, Doktycz MJ, Buchanan MV, Costello AM, Lidstrom ME. MALDI-TOF analysis of polymerase chain reaction products from methanotrophic bacteria. Anal Chem 1998; 70:2693-8. [PMID: 9666732 DOI: 10.1021/ac980044e] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Polymerase chain reaction (PCR) assays were designed to amplify 56- and 99-base regions of the pmoA gene from Methylosinus trichosporium OB3b and Methylomicrobium albus BG8, two species of methanotrophic bacteria that are of interest for monitoring bioremediation activity. The PCR product sizes are in a mass range that is accessible to analysis by MALDI-TOF mass spectrometry. A rapid purification procedure using commercially available reversed-phase cartridges was applied prior to MALDI-TOF analysis. A small aliquot (1.5%, 1.5 microL) from a single 100-microL PCR reaction was sufficient for reliable detection. No cross-amplification products were observed when primers designed for one bacterial species were used with genomic DNA of the other species. The methodology described here has potential to allow less expensive and faster characterization of the ability of microbial populations to destroy pollutants in groundwater and soil at contaminated industrial sites.
Collapse
Affiliation(s)
- G B Hurst
- Chemical and Analytical Sciences Division, Oak Ridge National Laboratory, Tennessee 37831, USA.
| | | | | | | | | | | |
Collapse
|
42
|
Burrows CJ, Muller JG. Oxidative Nucleobase Modifications Leading to Strand Scission. Chem Rev 1998; 98:1109-1152. [PMID: 11848927 DOI: 10.1021/cr960421s] [Citation(s) in RCA: 1395] [Impact Index Per Article: 53.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Cynthia J. Burrows
- Department of Chemistry, University of Utah, 315 S. 1400 East, Salt Lake City, Utah 84112-0850
| | | |
Collapse
|
43
|
Taniguchi H, Hayashi N. A liquid chromatography/electrospray mass spectrometric study on the post-transcriptional modification of tRNA. Nucleic Acids Res 1998; 26:1481-6. [PMID: 9490795 PMCID: PMC147412 DOI: 10.1093/nar/26.6.1481] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Liquid chromatography/electrospray mass spectrometry is one of the rapidly developing techniques with which mass of large hydrophilic polymers such as proteins and nucleic acids can be determined precisely. The technique was applied to studies on the modifications of tRNAs. Various tRNA species purified from Escherichia coli were directly injected into a capillary reversed-phase column and the desalted and concentrated tRNAs were analyzed on-line with an electrospray mass spectrometer. In some cases, small but significant differences were noted between the theoretical and observed molecular masses, suggesting that there exist still unknown modifications. Under high resolution measurements, multiple peaks corresponding to species modified to a varying extent were resolved. To study the structures in detail, the isolated tRNA species were digested with ribonuclease T1, and the resulting mixture of fragments were analyzed by the same liquid chromatography/mass spectrometry. In this way, most of the fragments were easily identified solely from their masses, and the positions where the expected and real structures differ were revealed. The results obtained showed the presence of micro-heterogeneity among tRNAs and demonstrated at the same time the power of the hyphenated technique for the structural analysis on nucleic acids.
Collapse
MESH Headings
- Anticodon/genetics
- Base Sequence
- Chromatography, Liquid
- Escherichia coli/genetics
- Escherichia coli/metabolism
- Mass Spectrometry
- Molecular Weight
- RNA Processing, Post-Transcriptional
- RNA, Bacterial/chemistry
- RNA, Bacterial/genetics
- RNA, Bacterial/metabolism
- RNA, Fungal/chemistry
- RNA, Fungal/genetics
- RNA, Fungal/metabolism
- RNA, Transfer/chemistry
- RNA, Transfer/genetics
- RNA, Transfer/metabolism
- RNA, Transfer, Glu/chemistry
- RNA, Transfer, Glu/genetics
- RNA, Transfer, Glu/metabolism
- RNA, Transfer, Lys/chemistry
- RNA, Transfer, Lys/genetics
- RNA, Transfer, Lys/metabolism
- RNA, Transfer, Met/chemistry
- RNA, Transfer, Met/genetics
- RNA, Transfer, Met/metabolism
- RNA, Transfer, Phe/chemistry
- RNA, Transfer, Phe/genetics
- RNA, Transfer, Phe/metabolism
- Ribonuclease T1
- Saccharomyces cerevisiae/genetics
- Saccharomyces cerevisiae/metabolism
Collapse
Affiliation(s)
- H Taniguchi
- Division of Biomedical Polymer Science, Institute for Comprehensive Medical Science, Fujita Health University, Toyoake, Aichi 470-1192, Japan.
| | | |
Collapse
|
44
|
Crain PF, McCloskey JA. Applications of mass spectrometry to the characterization of oligonucleotides and nucleic acids. Curr Opin Biotechnol 1998; 9:25-34. [PMID: 9503584 DOI: 10.1016/s0958-1669(98)80080-3] [Citation(s) in RCA: 70] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Mass spectrometry-based techniques continue to undergo active development for applications to nucleic acids, fueled by methods based on electrospray and matrix-assisted laser desorption ionization. In the past two years, notable advances have occurred in multiple interrelated areas, including sequencing techniques for oligonucleotides, approaches to mixture analysis, microscale sample handling and targeted DNA assays, and improvements in instrumentation for greater sensitivity and mass resolution.
Collapse
Affiliation(s)
- P F Crain
- University of Utah, Department of Medicinal Chemistry, Salt Lake City 84112-5820, USA.
| | | |
Collapse
|
45
|
Westman A, Brinkmalm G, Barofsky D. MALDI induced saturation effects in chevron microchannel plate detectors. ACTA ACUST UNITED AC 1997. [DOI: 10.1016/s0168-1176(97)00205-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
46
|
Xu L, Bian N, Wang Z, Abdel-Baky S, Pillai S, Magiera D, Murugaiah V, Giese RW, Wang P, O'Keeffe T, Abushamaa H, Kutney L, Church G, Carson S, Smith D, Park M, Wronka J, Laukien F. Electrophore mass tag dideoxy DNA sequencing. Anal Chem 1997; 69:3595-602. [PMID: 9286165 DOI: 10.1021/ac970066l] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Toward a goal of dideoxy sequencing DNA utilizing electrophore labels, we prepared four electrophore-labeled DNA oligonucleotide primers. Each primer has a different electrophore and DNA sequence but a common glycol keto (alpha,beta-dihydroxyketo) release group. Cleavage of this latter group by either periodate oxidation or a thermal retroaldol reaction releases the electrophores for detection by mass spectrometry. Successful sequencing data with these primers was obtained by capillary electrophoresis on an ABI Model 310 after fluorescence dideoxy terminator cycle sequencing reactions were conducted. In a separate experiment, it was demonstrated that a cocktail of the four electrophore DNA primers could be detected as a dried sample spot by CO2 laser desorption/capillary collection/gas chromatography electron capture mass spectrometry. These results establish some feasibility for our long-term goal of high-speed multiplex electrophore mass tag dideoxy DNA sequencing. Ultimately we plan to use a higher number of electrophore mass tags and to rely on direct detection of the desorbed electrophores by electron capture time-of-flight mass spectrometry.
Collapse
Affiliation(s)
- L Xu
- Department of Pharmaceutical Sciences, Bouve College of Pharmacy and Health Professions, Barnett Institute, Boston, Massachusetts, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
47
|
Apffel A, Chakel JA, Fischer S, Lichtenwalter K, Hancock WS. New procedure for the use of high-performance liquid chromatography–electrospray ionization mass spectrometry for the analysis of nucleotides and oligonucleotides. J Chromatogr A 1997. [DOI: 10.1016/s0021-9673(97)00256-2] [Citation(s) in RCA: 105] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
48
|
Grentzmann G, Kelly PJ. Ribosomal binding site of release factors RF1 and RF2. A new translational termination assay in vitro. J Biol Chem 1997; 272:12300-4. [PMID: 9139673 DOI: 10.1074/jbc.272.19.12300] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
We have established a new in vitro assay for translational termination. It consists of 70 S ribosomes bound to a synthetic RNA minimessenger via interaction with P-site binding fMet-tRNAfMet. If the A-site codon is a stop signal, release activity can be measured by quantifying hydrolyzed formylmethionine. Characteristics of this assay in terms of reaction time, ion concentration, release factor RF1 and RF2 concentration, and competition with A-site-decoding tRNA are discussed. The new assay shows that polypeptide chain release activity is directly dependent on the presence of a stop codon in the ribosomal A-site.
Collapse
Affiliation(s)
- G Grentzmann
- Eccles Institute of Human Genetics, Howard Hughes Medical Institute, Salt Lake City, Utah 84112, USA.
| | | |
Collapse
|
49
|
Cummins* LL, Winniman M, Gaus HJ. PHOSPHOROTHIOATE OLIGONUCLEOTIDE METABOLISM: CHARACTERIZATION OF THE “N+”-MER BY CE AND HPLC-ES/MS. Bioorg Med Chem Lett 1997. [DOI: 10.1016/s0960-894x(97)00201-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
50
|
Apffel A, Chakel JA, Fischer S, Lichtenwalter K, Hancock WS. Analysis of Oligonucleotides by HPLC−Electrospray Ionization Mass Spectrometry. Anal Chem 1997; 69:1320-5. [DOI: 10.1021/ac960916h] [Citation(s) in RCA: 296] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Alex Apffel
- Biomeasurements Group, Hewlett-Packard Laboratories, Palo Alto, California 94304, and California Analytical Division, Hewlett-Packard Company, Palo Alto, California 94304
| | - John A. Chakel
- Biomeasurements Group, Hewlett-Packard Laboratories, Palo Alto, California 94304, and California Analytical Division, Hewlett-Packard Company, Palo Alto, California 94304
| | - Steven Fischer
- Biomeasurements Group, Hewlett-Packard Laboratories, Palo Alto, California 94304, and California Analytical Division, Hewlett-Packard Company, Palo Alto, California 94304
| | - Kay Lichtenwalter
- Biomeasurements Group, Hewlett-Packard Laboratories, Palo Alto, California 94304, and California Analytical Division, Hewlett-Packard Company, Palo Alto, California 94304
| | - William S. Hancock
- Biomeasurements Group, Hewlett-Packard Laboratories, Palo Alto, California 94304, and California Analytical Division, Hewlett-Packard Company, Palo Alto, California 94304
| |
Collapse
|