1
|
Chen J, Wang X, Wang Y, Zhang Y, Peng Z, Tang X, Hu Y, Qiu P. Colorimetric detection of uric acid based on enhanced catalytic activity of cobalt-copper bimetallic-modified molybdenum disulfide. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
|
2
|
Karami Z, Sohrabi N, Badoei-dalfard A. A specific, rapid and high-throughput cascade catalytic method for determination of plasma uric acid by using uricase and trivalent peroxidase-mimicking DNAzyme. BIOCATALYSIS AND AGRICULTURAL BIOTECHNOLOGY 2020. [DOI: 10.1016/j.bcab.2020.101549] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
3
|
Badoei-dalfard A, Sohrabi N, Karami Z, Sargazi G. Fabrication of an efficient and sensitive colorimetric biosensor based on Uricase/ Th-MOF for uric acid sensing in biological samples. Biosens Bioelectron 2019; 141:111420. [DOI: 10.1016/j.bios.2019.111420] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Revised: 05/23/2019] [Accepted: 06/06/2019] [Indexed: 02/01/2023]
|
4
|
Tavallali H, Deilamy-Rad G, Mosallanejad N. A reversible and dual responsive sensing approach for determination of ascorbate ion in fruit juice, biological, and pharmaceutical samples by use of available triaryl methane dye and its application to constructing a molecular logic gate and a set/reset memorized device. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2019; 215:276-289. [PMID: 30836306 DOI: 10.1016/j.saa.2019.02.094] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 02/15/2019] [Accepted: 02/20/2019] [Indexed: 06/09/2023]
Abstract
Since dyes are available in huge quantities and have the well-established chemistry involved in their synthesis, their use in chemosensing could be continued. In the current study, a new and reversible colorimetric and fluorometric chemosensor based on available triaryl methane dye (brilliant green (BG)) - phosphotungstic acid (PTA) complex has been designed for determination of ascorbate (AscH-1) ion in water/DMSO (90:10v/v, 1.0mmolL-1 HEPES, pH7.0). The "ON-OFF" fluorescence and colorimetric responses of this ion association complex to AscH-1 were based on a displacement mechanism. For the detection of AscH-1, the linear ranges achieved for UV-Vis absorbance and fluorescence experiments were 3.9-62.6μmolL-1 and 1.9-85.4μmolL-1, respectively. The limits of detection for both of them were also calculated to be 0.4 and 0.2μmolL-1. The proposed method was also successfully utilized for rapid recognition of ascorbate in juice samples, human serum, and the formulation of supplement products. Moreover, the proposed chemosensor capability of functioning as INHIBITION-type sensor with PTA and AscH-1 as chemical inputs was indicated by the investigation of the molecular logic behavior of this chemosensor. Eventually, a sequential memory unit displaying "Write-Read-Erase-Read" function could be integrated based on the reversible and reproducible system.
Collapse
Affiliation(s)
- Hossein Tavallali
- Chemistry Department, The University of Payame Noor, 19395-4697 Tehran, Islamic Republic of Iran.
| | - Gohar Deilamy-Rad
- Chemistry Department, The University of Payame Noor, 19395-4697 Tehran, Islamic Republic of Iran
| | - Narges Mosallanejad
- Chemistry Department, The University of Payame Noor, 19395-4697 Tehran, Islamic Republic of Iran
| |
Collapse
|
5
|
Cao T, Zheng J, Xu J, Alharbi NS, Hayat T, Zhang M. Increasing enzyme-like activity by in situ anchoring of Ag 3PO 4 nanoparticles on keratin–inorganic hybrid nanoflowers. NEW J CHEM 2019. [DOI: 10.1039/c9nj03859k] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Herein, we propose a facile strategy of rapid assembly of Ag3PO4 nanoparticles within three dimensional (3D) keratin–inorganic hybrid nanoflowers (keratin-NF@Ag3PO4), which can be used for colorimetric detection of UA.
Collapse
Affiliation(s)
- Tiantian Cao
- College of Chemistry and Chemical Engineering
- Shanghai University of Engineering Science
- Shanghai 201620
- P. R. China
| | - Jing Zheng
- College of Chemistry and Chemical Engineering
- Shanghai University of Engineering Science
- Shanghai 201620
- P. R. China
| | - Jingli Xu
- College of Chemistry and Chemical Engineering
- Shanghai University of Engineering Science
- Shanghai 201620
- P. R. China
| | - Njud S. Alharbi
- Biotechnology Research Group
- Department of Biological Sciences
- Faculty of Science
- King Abdulaziz University
- Jeddah
| | - Tasawar Hayat
- Department of Mathematics
- Quaid-I-Azam University
- Islamabad 44000
- Pakistan
- NAAM Research Group
| | - Min Zhang
- College of Chemistry and Chemical Engineering
- Shanghai University of Engineering Science
- Shanghai 201620
- P. R. China
| |
Collapse
|
6
|
Pananon P, Sriprachuabwong C, Wisitsoraat A, Chuysinuan P, Tuantranont A, Saparpakorn P, Dechtrirat D. A facile one-pot green synthesis of gold nanoparticle-graphene-PEDOT:PSS nanocomposite for selective electrochemical detection of dopamine. RSC Adv 2018; 8:12724-12732. [PMID: 35541276 PMCID: PMC9079364 DOI: 10.1039/c8ra01564c] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Accepted: 03/27/2018] [Indexed: 11/25/2022] Open
Abstract
A facile one-pot and green method was developed to prepare a nanocomposite of gold nanoparticle (AuNP), graphene (GP) and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). Graphene was first electro-exfoliated in a polystyrene sulfonate solution, followed by a one-step simultaneous in situ formation of gold nanoparticle and PEDOT. The as-synthesized aqueous dispersion of AuNP-GP-PEDOT:PSS was thereafter used to modify the glassy carbon electrode (GCE). For the first time, the quaternary composite between AuNP, GP, PEDOT and PSS was used for selective determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA). In comparison to a bare GCE, the nanocomposite electrode shows considerably higher electrocatalytic activities toward the oxidation of DA and UA due to a synergistic effect between AuNP, GP, PEDOT and PSS. Using differential pulse voltammetry (DPV), selective determination of DA and UA in the presence of AA could be achieved with a peak potential separation of 110 mV between DA and UA. The sensor exhibits wide linear responses for DA and UA in the ranges of 1 nM to 300 μM and 10 μM to 1 mM with detection limits (S/N = 3) of 100 pM and 10 μM, respectively. Furthermore, the proposed sensor was also successfully used to determine DA in a real pharmaceutical injection sample as well as DA and UA in human serum with satisfactory recovery results. A facile one-pot green synthesis of gold nanoparticle-graphene-PEDOT:PSS nanocomposite was successfully demonstrated.![]()
Collapse
Affiliation(s)
- Paweena Pananon
- Department of Materials Science
- Faculty of Science
- Kasetsart University
- Bangkok
- Thailand
| | | | - Anurat Wisitsoraat
- National Electronics and Computer Technology Center (NECTEC)
- National Science and Technology Development Agency (NSTDA)
- Thailand
| | | | - Adisorn Tuantranont
- National Electronics and Computer Technology Center (NECTEC)
- National Science and Technology Development Agency (NSTDA)
- Thailand
| | | | - Decha Dechtrirat
- Department of Materials Science
- Faculty of Science
- Kasetsart University
- Bangkok
- Thailand
| |
Collapse
|
7
|
Jin D, Seo MH, Huy BT, Pham QT, Conte ML, Thangadurai D, Lee YI. Quantitative determination of uric acid using CdTe nanoparticles as fluorescence probes. Biosens Bioelectron 2016; 77:359-65. [DOI: 10.1016/j.bios.2015.09.057] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Revised: 09/24/2015] [Accepted: 09/25/2015] [Indexed: 12/30/2022]
|
8
|
Pal J, Pal T. Enzyme mimicking inorganic hybrid Ni@MnO2 for colorimetric detection of uric acid in serum samples. RSC Adv 2016. [DOI: 10.1039/c6ra11483k] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Reliable and inexpensive detection of uric acid in the absence of any peroxide or enzyme is very challenging for the development of a new cost effective clinical method.
Collapse
Affiliation(s)
- Jaya Pal
- Department of Chemistry
- Indian Institute of Technology
- Kharagpur-721302
- India
| | - Tarasankar Pal
- Department of Chemistry
- Indian Institute of Technology
- Kharagpur-721302
- India
| |
Collapse
|
9
|
Kanďár R. The ratio of oxidized and reduced forms of selected antioxidants as a possible marker of oxidative stress in humans. Biomed Chromatogr 2015; 30:13-28. [PMID: 26053056 DOI: 10.1002/bmc.3529] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Revised: 05/20/2015] [Accepted: 05/29/2015] [Indexed: 02/04/2023]
Abstract
Oxidative stress is an imbalance between reactive oxygen species exposure and the ability of organisms to detoxify the reactive intermediates and to repair the oxidative damage of biologically important molecules. Many clinical studies of oxidative stress unfortunately provide conflicting and contradictory results. The ability of antioxidant systems to adequately respond to oxidative stress can be used in laboratory diagnostics. In the present review, methods using the ratio of reduced and oxidized forms of uric acid, ascorbic acid, glutathione and coenzyme Q10 as suitable indicators of oxidative stress are discussed. From the mentioned publications it is evident that suitable sample preparation prior to analysis is crucial.
Collapse
Affiliation(s)
- Roman Kanďár
- Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Pardubice, Czech Republic
| |
Collapse
|
10
|
Lu J, Xiong Y, Liao C, Ye F. Colorimetric detection of uric acid in human urine and serum based on peroxidase mimetic activity of MIL-53(Fe). ANALYTICAL METHODS 2015; 7:9894-9899. [DOI: 10.1039/c5ay02240a] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2023]
Abstract
The porous metal–organic framework MIL-53(Fe) was prepared using a simple solvothermal method, and was developed as a colorimetric sensor for the detection of uric acid in human urine and serum.
Collapse
Affiliation(s)
- Junyu Lu
- College of Chemistry and Biology Engineering
- Hechi University
- Yizhou 546300
- China
| | - Yuhao Xiong
- Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China)
- School of Chemistry and Pharmaceutical Sciences
- Guangxi Normal University
- Guilin 541004
- China
| | - Chunjin Liao
- Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China)
- School of Chemistry and Pharmaceutical Sciences
- Guangxi Normal University
- Guilin 541004
- China
| | - Fanggui Ye
- Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China)
- School of Chemistry and Pharmaceutical Sciences
- Guangxi Normal University
- Guilin 541004
- China
| |
Collapse
|
11
|
Identification of uric acid as the redox molecule secreted by the yeast Arxula adeninivorans. Appl Microbiol Biotechnol 2014; 98:2223-9. [DOI: 10.1007/s00253-013-5487-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2013] [Revised: 12/12/2013] [Accepted: 12/15/2013] [Indexed: 02/04/2023]
|
12
|
Han SQ, Zhao SM. A Novel Method for Uric Acid Determination Using CdS Quantum Dots as Fluorescence Probes. J CHIN CHEM SOC-TAIP 2013. [DOI: 10.1002/jccs.200900166] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
13
|
Fattorini P, Marrubini G, Grignani P, Sorçaburu-Cigliero S, Previderé C. Assessment of DNA damage by micellar electrokinetic chromatography. Methods Mol Biol 2013; 984:341-51. [PMID: 23386356 DOI: 10.1007/978-1-62703-296-4_25] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/20/2023]
Abstract
A simple and inexpensive MEKC method, which is able to assess base damage within DNA samples, is illustrated. After heat-acid hydrolysis of the DNA samples, both the percentage of each canonical DNA base and the relative amount of uncanonical DNA bases can be measured. This method is useful for an evaluation of the integrity of PCR templates used in several fields of investigation.
Collapse
Affiliation(s)
- Paolo Fattorini
- Department of Medicine, surgery and Health, University of Trieste, Trieste, Italy.
| | | | | | | | | |
Collapse
|
14
|
Talik P, Krzek J, Ekiert RJ. Analytical Techniques Used for Determination of Methylxanthines and their Analogues—Recent Advances. SEPARATION AND PURIFICATION REVIEWS 2012. [DOI: 10.1080/15422119.2011.569047] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
15
|
The determination of ascorbic acid and uric acid in human seminal plasma using an HPLC with UV detection. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:2834-9. [DOI: 10.1016/j.jchromb.2011.08.007] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2011] [Revised: 08/06/2011] [Accepted: 08/08/2011] [Indexed: 02/04/2023]
|
16
|
Zinellu A, Sotgia S, Deiana L, Carru C. Field-amplified sample injection combined with pressure-assisted capillary electrophoresis UV detection for the simultaneous analysis of allantoin, uric acid, and malondialdehyde in human plasma. Anal Bioanal Chem 2011; 399:2855-61. [DOI: 10.1007/s00216-010-4648-x] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2010] [Revised: 12/17/2010] [Accepted: 12/22/2010] [Indexed: 02/05/2023]
|
17
|
Yang J, Hu M, Cai Y, Tang J, Li H. Determination of uric acid in human urine by capillary zone electrophoresis with indirect laser-induced fluorescence detection. J Sep Sci 2010; 33:3710-6. [DOI: 10.1002/jssc.201000334] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
18
|
Georgakopoulos CD, Lamari FN, Karathanasopoulou IN, Gartaganis VS, Pharmakakis NM, Karamanos NK. Tear analysis of ascorbic acid, uric acid and malondialdehyde with capillary electrophoresis. Biomed Chromatogr 2010; 24:852-7. [PMID: 20024890 DOI: 10.1002/bmc.1376] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Tears have a significant role in antioxidant defense in ocular tissues and since their collection is quick and noninvasive, their analysis would facilitate monitoring of pathophysiological changes. However, their low volume and low content of antioxidants makes analysis difficult; methods of high sensitivity are needed. In this paper, we present a method for tear analysis of two antioxidant molecules (ascorbic and uric acid) and of a lipid peroxidation indicator (malondialdehyde) with capillary electrophoresis. Tears were collected with Schirmer strips, extracted with a low-pH phosphate buffer, centrifuged through membrane filters and an antioxidant was added. They were stable at -70 degrees C for 15 days. After pilot experiments, optimum electrophoretic separation was achieved in a 25 mM borate buffer, pH 10.0, containing 100 mM sodium dodecyl sulfate at 25 degrees C and 20 kV. The developed method has good repeatability (<5% RSD), precision (<15% relative error values) and high sensitivity (LLOQ values of 20, 2.3 and 2.5 microM for ascorbate, urate and malondialdehyde, respectively). It was applied to the analysis of tears from healthy individuals and the antioxidant levels are in agreement with those obtained with other techniques. This method might serve as a tool to clarify the role of endogenous antioxidants in the pathophysiology of ocular diseases.
Collapse
|
19
|
Loizzo S, Vella S, Loizzo A, Fortuna A, Di Biase A, Salvati S, Frajese GV, Agrapart V, Ramirez Morales R, Spampinato S, Campana G, Capasso A, Galietta G, Guarino I, Carta S, Carru C, Zinellu A, Ghirlanda G, Seghieri G, Renzi P, Franconi F. Sexual dimorphic evolution of metabolic programming in non-genetic non-alimentary mild metabolic syndrome model in mice depends on feed-back mechanisms integrity for pro-opiomelanocortin-derived endogenous substances. Peptides 2010; 31:1598-605. [PMID: 20493223 DOI: 10.1016/j.peptides.2010.05.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2009] [Revised: 05/12/2010] [Accepted: 05/12/2010] [Indexed: 01/05/2023]
Abstract
Previously, we showed that our post-natal handling model induces pro-opiomelanocortin-derived (POMC) endogenous systems alterations in male mice at weaning. These alterations last up to adult age, and are at the basis of adult hormonal and metabolic conditions similar to mild metabolic syndrome/type-2 diabetes. Here, we evaluate how sex influences post-natal programming in these metabolic conditions. Subjects are adult control (non-handled) female (NHF) and male (NHM) CD-1 mice; adult post-natal handled female (HF) and male (HM) mice. Handling consists of daily maternal separation (10 min) plus sham injection, from birth to weaning (21 days). In adult handled males (90-days old) we find not only POMC-derived hormones alterations (enhanced basal plasma corticosterone (+91%) and ACTH (+109%)) but also overweight (+5.4%), fasting hyperglycemia (+40%), hypertriglyceridemia (+21%), enhanced brain mRNA expression of hydroxysteroid(11-beta)dehydrogenase type-1 (HSD11B1) (+49%), and decreased mRNA-HSD11B2 (-39%). Conversely, uric acid, creatinine, HDL(C), total cholesterol, glucose and insulin incremental area under-the-curve are not affected. In females, post-natal handling does not produce both hormonal and dysmetabolic diabetes-like changes; but handling enhances n3- and n6-poly-unsaturated, and decreases saturated fatty acids content in erythrocyte membrane composition in HF versus NHF. In conclusion, for the first time we show that female sex in mice exerts effective protection against the hypothalamus-pituitary-adrenal homeostasis disruption induced by our post-natal handling model on POMC cleavage products; endocrine disruption is in turn responsible for altered metabolic programming in male mice. The role of sex hormones is still to be elucidated.
Collapse
MESH Headings
- 11-beta-Hydroxysteroid Dehydrogenase Type 1/genetics
- 11-beta-Hydroxysteroid Dehydrogenase Type 1/metabolism
- 11-beta-Hydroxysteroid Dehydrogenase Type 2/genetics
- 11-beta-Hydroxysteroid Dehydrogenase Type 2/metabolism
- Adrenocorticotropic Hormone/blood
- Animals
- Animals, Newborn
- Brain/metabolism
- Corticosterone/blood
- Diabetes Mellitus, Type 2/blood
- Diabetes Mellitus, Type 2/etiology
- Diabetes Mellitus, Type 2/metabolism
- Feedback, Physiological
- Female
- Gene Expression Regulation, Enzymologic
- Handling, Psychological
- Hypothalamo-Hypophyseal System/metabolism
- Hypothalamo-Hypophyseal System/physiopathology
- Lipid Metabolism/physiology
- Male
- Metabolic Syndrome/blood
- Metabolic Syndrome/etiology
- Metabolic Syndrome/metabolism
- Metabolic Syndrome/physiopathology
- Mice
- Pain Threshold/physiology
- Pituitary-Adrenal System/metabolism
- Pituitary-Adrenal System/physiopathology
- Pro-Opiomelanocortin/metabolism
- RNA, Messenger/metabolism
- Random Allocation
- Sex Characteristics
- Stress, Psychological/complications
- Stress, Psychological/physiopathology
Collapse
Affiliation(s)
- Stefano Loizzo
- Department of Therapeutic Research and Medicines Evaluation, Istituto Superiore di Sanità, via Regina Elena 299, 00161 Roma, Italy.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Fattorini P, Marrubini G, Ricci U, Gerin F, Grignani P, Sorçaburu Cigliero S, Xamin A, Edalucci E, La Marca G, Previderé C. Estimating the integrity of aged DNA samples by CE. Electrophoresis 2009; 30:3986-95. [DOI: 10.1002/elps.200900283] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
21
|
Pormsila W, Krähenbühl S, Hauser PC. Capillary electrophoresis with contactless conductivity detection for uric acid determination in biological fluids. Anal Chim Acta 2009; 636:224-8. [DOI: 10.1016/j.aca.2009.02.012] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2008] [Revised: 02/05/2009] [Accepted: 02/05/2009] [Indexed: 11/26/2022]
|
22
|
Kand'ár R, Záková P. Determination of ascorbic acid in human plasma with a view to stability using HPLC with UV detection. J Sep Sci 2009; 31:3503-8. [PMID: 18830961 DOI: 10.1002/jssc.200800303] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
A method for the measurement of ascorbic acid using HPLC with UV detection and investigation into the protein precipitation techniques with regard to stability and recovery are described. The effectiveness of various protein precipitants was tested. Stability of ascorbic acid samples for analysis was investigated over 10 h. Ascorbic acid samples extracted with metaphosphoric acid were stable on a cooled autosampler (4 degrees C) for at least 10 h (with a decline of 1.8% for ascorbic acid solution and 2.8% for plasma). Perchloric acid as protein precipitant for ascorbic acid was unsuitable (with a decline of 36.0% for ascorbic acid solution and 7.3% for plasma). Analytical performance of this method is satisfactory. The intra- and interassay coefficients of variation were 2.1% (n = 10) and 5.8% (n = 12), respectively. The calibration curve was linear with the tested range of 2.0-250.0 micromol/L. The recovery was 96.1% with CV = 4.8% (n = 6) and the LOD was 3 micromol/L. The preliminary reference ranges of ascorbic acid in a group of blood donors are 50.8 +/- 22.4 micromol/L. This assay is a highly sensitive and reproducible HPLC method for the determination of ascorbic acid in human plasma.
Collapse
Affiliation(s)
- Roman Kand'ár
- Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Pardubice, Czech Republic.
| | | |
Collapse
|
23
|
Zhao S, Wang J, Ye F, Liu YM. Determination of uric acid in human urine and serum by capillary electrophoresis with chemiluminescence detection. Anal Biochem 2008; 378:127-31. [DOI: 10.1016/j.ab.2008.04.014] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2007] [Revised: 04/04/2008] [Accepted: 04/07/2008] [Indexed: 11/28/2022]
|
24
|
Nojavan S, Khalilian F, Kiaie FM, Rahimi A, Arabanian A, Chalavi S. Extraction and quantitative determination of ascorbic acid during different maturity stages of Rosa canina L. fruit. J Food Compost Anal 2008. [DOI: 10.1016/j.jfca.2007.11.007] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
25
|
Liu A, Chen W, Huang L, Lin X. A Polymer Film Modified Sensor for Voltammetric Determination of Uric Acid in the Presence of Ascorbic Acid and Its Application in Urine. Chem Pharm Bull (Tokyo) 2008; 56:1665-9. [DOI: 10.1248/cpb.56.1665] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Affiliation(s)
- Ailin Liu
- Department of Pharmaceutical Analysis, Faculty of Pharmacy, Fujian Medical University
| | - Wei Chen
- Department of Pharmaceutical Analysis, Faculty of Pharmacy, Fujian Medical University
| | - Liying Huang
- Department of Pharmaceutical Analysis, Faculty of Pharmacy, Fujian Medical University
| | - Xinhua Lin
- Department of Pharmaceutical Analysis, Faculty of Pharmacy, Fujian Medical University
| |
Collapse
|
26
|
Matejcková J, Tůma P, Samcová E, Zemanová Z. Determination of uric acid in plasma and allantoic fluid of chicken embryos by capillary electrophoresis. J Sep Sci 2007; 30:1947-52. [PMID: 17638368 DOI: 10.1002/jssc.200700046] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Capillary electrophoresis with diode array detection (DAD) was used to determine uric acid (UA) in chicken plasma and the allantoic fluid of chicken embryos. Complete separation of uric and ascorbic acids was attained in less than 10 min in the optimized BGE containing 60 mM MES + 30 mM Tris + 0.001% (w/v) polybrene (pH 6.1). The limit of UA detection (0.2 mg/L) was found to be low enough for sensitive analysis of native plasma and allantoic fluid samples. Range of linearity (1-200 mg/L), repeatability for peak area (CV <4.1%) and migration time (CV < 2.5%), as well as recovery of UA from biological samples (97-100%), were found to be satisfactory. The method was applied to detect the elevated UA concentrations (hyperuricemia) in chicken embryos with induced unilateral renal agenesis. CE/DAD analysis of the chicken plasma can be carried out with a relatively small volume of samples (1 microL).
Collapse
Affiliation(s)
- Jana Matejcková
- Department of Analytical Chemistry, Charles University, Ruská 87, 100 00 Prague 10, Czech Republic
| | | | | | | |
Collapse
|
27
|
Caussé E, Pradelles A, Dirat B, Negre-Salvayre A, Salvayre R, Couderc F. Simultaneous determination of allantoin, hypoxanthine, xanthine, and uric acid in serum/plasma by CE. Electrophoresis 2007; 28:381-7. [PMID: 17177243 DOI: 10.1002/elps.200600205] [Citation(s) in RCA: 108] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Allantoin (All) is an oxidative end product of purines in mammals. The small amount of All present in human plasma or serum results from free radical action on urate and may provide a stable marker of in vivo free radical activity. Because free radicals have been implicated in the development and progression of atherosclerosis, this study focused on the metabolic compounds of the All pathway. We propose a new fast CE (CE/UV) method for the simultaneous determination of All, uric acid (UA), hypoxanthine (HX), and xanthine (X) in human plasma. These products were quantified in the plasma of patients with chronic renal failure before hemodialysis (n = 6), patients with chronic heart failure (n = 6) and controls (n = 6). The filtered plasma were diluted ten-fold before the direct injection in CE/UV (195 nm), which allows separating the four compounds in less than 13 min. The metabolites were detectable at concentrations of 0.3-0.6 micromol/L. The method was linear over the range 0.5-150 micromol/L for All, HX, and X and 10-1500 micromol/L for UA (r > 0.99). The analytical performance of this method is satisfactory with intra-assay CV < 3.4%, inter-assay CV < 5% (HX and X < 7%), and recovery (93-101%). The proposed CE-UV method appears to be a useful tool for studying physiological and pathological changes of HX, UA, and All levels in plasma samples, the latter being a possible indicator of free radical damage in vivo.
Collapse
Affiliation(s)
- Elizabeth Caussé
- Laboratoire de Biochimie and INSERM U466, Centre Hospitalier Rangueil, Toulouse, France.
| | | | | | | | | | | |
Collapse
|
28
|
Zhang QL, Xu JJ, Lian HZ, Li XY, Chen HY. Polycation coating poly(dimethylsiloxane) capillary electrophoresis microchip for rapid separation of ascorbic acid and uric acid. Anal Bioanal Chem 2007; 387:2699-704. [PMID: 17318514 DOI: 10.1007/s00216-007-1173-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2006] [Revised: 01/27/2007] [Accepted: 01/31/2007] [Indexed: 11/26/2022]
Abstract
A novel method for rapid separation and determination of ascorbic acid and uric acid has been developed with a polycation-modified poly(dimethylsiloxane) (PDMS) microchip under a negative-separation electric field. Just by flushing the microchip with aqueous solutions of the polycations, poly(allylamine) hydrochloride, poly(diallyldimethylammonium chloride) or chitosan could be stably coated on the PDMS microchannel surface, which resulted in a reversed electroosmotic flow and thus the rapid and efficient separation of the two substrates. Factors influencing the separation, including polycation category, buffer solution, detection potential and separation voltage, were investigated and optimized. The cheapness, rapid analysis speed and the successful analysis of human urine make this microsystem attractive for application in clinics.
Collapse
Affiliation(s)
- Q L Zhang
- The Key Lab of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093, China
| | | | | | | | | |
Collapse
|
29
|
Yao X, Wang Y, Chen G. Simultaneous determination of aminothiols, ascorbic acid and uric acid in biological samples by capillary electrophoresis with electrochemical detection. Biomed Chromatogr 2007; 21:520-6. [PMID: 17294501 DOI: 10.1002/bmc.787] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A method based on capillary electrophoresis with electrochemical detection has been employed for the separation and determination of homocysteine, cysteine, reduced glutathione, ascorbic acid and uric acid. Effects of several important factors such as the acidity and concentration of the running buffer, separation voltage, injection time and detection potential were investigated to acquire the optimum conditions. The detection electrode was a 500 microm diameter platinum disk electrode at a working potential of +1.05 V (vs saturated calomel electrode). The five analytes were well separated within 10 min in a 50 cm long fused silica capillary at a separation voltage of 18 kV in a 100 mm phosphate buffer (pH 7.8). The relation between peak current and analyte concentration was linear over about 3 orders of magnitude with the detection limits (S/N = 3) ranging from 0.83 to 2.58 microm. The proposed method was successfully applied to determine cysteine, reduced glutathione, ascorbic acid and uric acid in human whole blood and rat brain tissues with satisfactory assay results and should find a wide range of bioanalytical applications.
Collapse
Affiliation(s)
- Xiao Yao
- Department of Chemistry, Fudan University, Shanghai 200433, People's Republic of China
| | | | | |
Collapse
|
30
|
Chu QC, Lin M, Geng CH, Ye JN. Determination of Uric Acid in Human Saliva and Urine Using Miniaturized Capillary Electrophoresis with Amperometric Detection. Chromatographia 2006. [DOI: 10.1365/s10337-006-0142-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
31
|
Zinellu A, Sotgia S, Deiana L, Carru C. Pre-analytical factors affecting ascorbic and uric acid quantification in human plasma. ACTA ACUST UNITED AC 2006; 67:95-105. [PMID: 16519944 DOI: 10.1016/j.jbbm.2006.01.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2005] [Revised: 01/09/2006] [Accepted: 01/19/2006] [Indexed: 02/04/2023]
Abstract
We have recently described a new capillary electrophoresis assay to measure serum ascorbic and uric acids in which a baseline separation of peaks was obtained in less than 4 min by using a 60.2 cm x 75 microm uncoated capillary with a 100 mmol/L sodium borate running buffer pH 8. Since during sample preparation AA is rapidly oxidized, we employed our new capillary electrophoresis method to analyze the pre-analytical factors affecting its stability. In particular we evaluated how the standard mix preparation, the blood collection (plasma EDTA or serum) and the plasma protein precipitation influence the results of analysis. Our data suggest that standard ascorbate must be dissolved in a solution containing cysteine and EDTA in order to avoid oxidation and that EDTA blood collection is better than serum for AA measurement. Moreover, the type and the quantity of the precipitating compound are critical parameters to obtain a complete recovery of analytes. We performed AA and UA analysis in 32 healthy volunteers with the optimized experimental conditions by using our capillary electrophoresis method and a reference CE assay. Obtained data were compared to Bland-Altman test to verify the accuracy of our CZE method.
Collapse
Affiliation(s)
- Angelo Zinellu
- Department of Biomedical Sciences, Chair of Clinical Biochemistry, University of Sassari, Viale San Pietro 43/B, I-07100 Sassari, Italy.
| | | | | | | |
Collapse
|
32
|
Zinellu A, Sotgia S, Caddeo S, Deiana L, Carru C. Sodium glycylglycine as effective electrolyte run buffer for ascorbic and uric acid separation by CZE: A comparison with two other CE assays. J Sep Sci 2005; 28:2193-9. [PMID: 16318217 DOI: 10.1002/jssc.200500109] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
A new CE method for ascorbic acid (AA) and uric acid (UA) detection in human plasma has been developed. Analytes were resolved in less than 4 min by employing sodium glycylglycine (Glygly) as electrolyte run buffer at pH 8.0. Using the diode array detector ability to measure multiple wavelengths simultaneously, detection was optimized by monitoring the run at 262 nm for AA and at 288 nm for UA. Electrophoretic parameters such as resolution, migration times, efficiency, and peak areas of this new method were compared to those obtained by the two CE assays described in literature, in which the analytes separation was achieved by using sodium borate (that allows faster migration times but poor resolution) or tricine (with the highest resolution but elevated migration times) as electrolyte run buffer. Sodium Glygly allows to obtain the same good resolution given by the tricine buffer but with the faster analysis times of the sodium borate run buffer. Ascorbate and urate levels were measured in 35 healthy volunteers by the three methods and the obtained data were compared by three different statistical tests (mountain plot, Passing-Bablok regression, and Bland-Altman test) in order to verify the accuracy of our proposed method.
Collapse
Affiliation(s)
- Angelo Zinellu
- Clinical Biochemistry, University of Sassari, Sassari, Italy
| | | | | | | | | |
Collapse
|