1
|
Ren Y, Liu Y, Zhang W, Ran J, Li L, Zhang Z. Sheathless CESI-MS versus LC-MS: Results of qualitative and quantitative analyses of the primary and secondary metabolites of Pleioblastus amarus bamboo shoots. Electrophoresis 2024; 45:266-274. [PMID: 37817363 DOI: 10.1002/elps.202300030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 09/05/2023] [Accepted: 09/11/2023] [Indexed: 10/12/2023]
Abstract
The bamboo shoot of Pleioblastus amarus (Keng) Keng f. is a medicinal and edible resource in China. In this study, three separation techniques were applied to identify the primary and secondary metabolites component of P. amarus bamboo shoots, including sheathless capillary electrophoresis electrospray ionization-mass spectrometry (CESI-MS), reverse-phase liquid chromatography-MS (RPLC-MS), and hydrophilic interaction liquid chromatography-MS (HILIC-MS). A total of 201 metabolites were identified by the three methods. Among those metabolites, 146 were identified by RPLC-MS, 85 were identified by HILIC-MS, and 46 were identified by sheathless CESI-MS. These methods were complementary and had a linear coefficient. CESI-MS presented advantages in the identification of isomers, high sensitivity, very low sample usage, and good detection of polar and nonpolar metabolites, showing its unique applications in food analysis and prospects in metabolic research.
Collapse
Affiliation(s)
- Yan Ren
- College of Pharmacy, Southwest Minzu University, Chengdu, Sichuan, P. R. China
| | - Ying Liu
- Beijing National Laboratory for Molecular Sciences (BNLMS), Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Analytical Instrumentation Center, College of Chemistry and Molecular Engineering, Peking University, Beijing, P. R. China
| | - Wenming Zhang
- College of Pharmacy, Southwest Minzu University, Chengdu, Sichuan, P. R. China
| | - Junfeng Ran
- College of Pharmacy, Southwest Minzu University, Chengdu, Sichuan, P. R. China
| | - Li Li
- The Sixth People's Hospital of Hengshui, Hengshui, Hebei, P. R. China
| | - Zhidan Zhang
- Key Laboratory of Engineering Biology for Low-Carbon Manufacturing, Systems Biology Centre, Technical Support Core Facilities, Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences, Tianjin, P. R. China
| |
Collapse
|
2
|
Deng L, Fu Q, Zhang Y, Shui F, Tang J, Wu J, Zeng J. Study of molecular interactions by nonequilibrium capillary electrophoresis of equilibrium mixtures: Originations, developments, and applications. Electrophoresis 2023; 44:1664-1673. [PMID: 37621032 DOI: 10.1002/elps.202300166] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 08/16/2023] [Accepted: 08/18/2023] [Indexed: 08/26/2023]
Abstract
Molecular interactions play a vital role in regulating various physiological and biochemical processes in vivo. Kinetic capillary electrophoresis (KCE) is an analytical platform that offers significant advantages in studying the thermodynamic and kinetic parameters of molecular interactions. It enables the simultaneous analysis of these parameters within an interaction pattern and facilitates the screening of binding ligands with predetermined kinetic parameters. Nonequilibrium capillary electrophoresis of equilibrium mixtures (NECEEM) was the first proposed KCE method, and it has found widespread use in studying molecular interactions involving proteins/aptamers, proteins/small molecules, and peptides/small molecules. The successful applications of NECEEM have demonstrated its promising potential for further development and broader application. However, there has been a dearth of recent reviews on NECEEM. To address this gap, our study provides a comprehensive description of NECEEM, encompassing its origins, development, and applications from 2015 to 2022. The primary focus of the applications section is on aptamer selection and screening of small-molecule ligands. Furthermore, we discuss important considerations in NECEEM experimental design, such as buffer suitability, detector selection, and protein adsorption. By offering this thorough review, we aim to contribute to the understanding, advancement, and wider utilization of NECEEM as a valuable tool for studying molecular interactions and facilitating the identification of potential ligands and targets.
Collapse
Affiliation(s)
- Li Deng
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, P. R. China
| | - Qifeng Fu
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, P. R. China
| | - Yujie Zhang
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, P. R. China
| | - Fan Shui
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, P. R. China
| | - Jia Tang
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, P. R. China
| | - Jianming Wu
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, P. R. China
- School of Basic Medical Science, Southwest Medical University, Luzhou, Sichuan, P. R. China
| | - Jing Zeng
- School of Pharmacy, Southwest Medical University, Luzhou, Sichuan, P. R. China
| |
Collapse
|
3
|
Ku K, Frey C, Arad M, Ghafourifar G. Development of novel enzyme immobilization methods employing formaldehyde or triethoxysilylbutyraldehyde to fabricate immobilized enzyme microreactors for peptide mapping. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:4053-4063. [PMID: 36196924 DOI: 10.1039/d2ay00840h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
The digestion of proteins with proteolytic enzymes has expedited the analysis of peptide mapping. Here, we compared the digestion efficiency of soluble chymotrypsin (CT) with two immobilized CT preparations using bovine serum albumin (BSA) as the substrate. An efficient method of immobilizing chymotrypsin using formaldehyde (FA) was optimized and the conditions were applied to assess a novel immobilization reagent, triethoxysilylbutaraldehyde (TESB). Efforts to determine the best enzyme-to-substrate (E : S) ratios during digestion of denatured BSA with single-use FA-CT enzyme particles were performed by adjusting the amount of substrate used. An E : S ratio of 10 : 1 was found to be best based on the LC-MS/MS analysis data showing sequence coverage of 67%. Fabrication of immobilized enzyme microreactors (IMERs) was carried out using both (3-aminopropyl)triethoxysilane (APTES) with the idealized conditions with FA, as well as the novel procedure utilizing TESB for a proof of concept open-tubular IMER. It was found that the FA-APTES IMER had a sequence coverage of 6%, while the TESB IMER had 29% sequence coverage from MS analysis. The application of TESB in enzyme immobilization has the potential to facilitate a greater degree of enzymatic digestion with higher sequence coverage than traditional immobilization or crosslinking reagents for bottom-up proteomics.
Collapse
Affiliation(s)
- Kenneth Ku
- Department of Chemistry, University of the Fraser Valley, 33844 King Road, Abbotsford, British Columbia, V2S 7M8, Canada.
| | - Connor Frey
- Department of Chemistry, University of the Fraser Valley, 33844 King Road, Abbotsford, British Columbia, V2S 7M8, Canada.
| | - Maor Arad
- Department of Chemistry, University of the Fraser Valley, 33844 King Road, Abbotsford, British Columbia, V2S 7M8, Canada.
| | - Golfam Ghafourifar
- Department of Chemistry, University of the Fraser Valley, 33844 King Road, Abbotsford, British Columbia, V2S 7M8, Canada.
| |
Collapse
|
4
|
Mora MF, Kok MGM, Noell A, Willis PA. Detection of Biosignatures by Capillary Electrophoresis Mass Spectrometry in the Presence of Salts Relevant to Ocean Worlds Missions. ASTROBIOLOGY 2022; 22:914-925. [PMID: 35913998 DOI: 10.1089/ast.2021.0091] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Capillary electrophoresis (CE) is a promising liquid-based technique for in situ chemical analysis on ocean worlds that allows the detection of a wide range of organic molecules relevant to the search for life. CE coupled with mass spectrometry (MS) is particularly valuable as it also enables the discovery of unknown compounds. Here we demonstrate that CE coupled to MS via electrospray ionization (ESI) can readily analyze samples containing up to half the saturation levels of salts relevant to ocean worlds when using 5 M acetic acid as the separation media. A mixture containing amino acids, peptides, nucleobases, and nucleosides was analyzed in the presence of two salts, NaCl and MgSO4, based on their relevance to Europa and Enceladus. We demonstrate here CE-MS limits of detection for these organics ranging from 0.05 to 1 μM (8 to 89 ppb) in the absence of salts. More importantly, we demonstrate here for the first time that organics in the low micromolar range (1-50 μM) are detected by CE-MS in the presence of 3 M NaCl without desalting, preconcentration, or derivatization. This demonstration highlights how CE-MS is uniquely suited for organic analysis on future missions to ocean worlds.
Collapse
Affiliation(s)
- Maria F Mora
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Miranda G M Kok
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Aaron Noell
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| | - Peter A Willis
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California, USA
| |
Collapse
|
5
|
Yan P, Zhang K, Wang L, Tong W, Chen DDY. Quantitative analysis of microcystin variants by capillary electrophoresis mass spectrometry with dynamic pH barrage junction focusing. Electrophoresis 2019; 40:2285-2293. [PMID: 30924152 DOI: 10.1002/elps.201900042] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Revised: 03/04/2019] [Accepted: 03/24/2019] [Indexed: 01/08/2023]
Abstract
Dynamic pH junction is an online focusing method in CE based on the electrophoretic mobility difference of analytes in the sample matrix and the background electrolyte. An advantage of this method over the conventional CE is that the sensitivity can be significantly improved. By injecting a long sample plug in the capillary and focusing the analytes at the pH boundary between the background electrolyte and sample matrix, the LOD can be improved by 10-100 folds. The dynamic pH junction method can be easily coupled with ESI-MS. In this work, we used this method for the analysis of microcystins (MCs). The detection limits and dynamic ranges were studied. The separation was optimized by adjusting the injection time, and concentrations and pH values of the background electrolyte. The optimization of analyte focusing leads to enhanced detection response compared to conventional injections, achieving 200-400 fold higher averaged peak heights for four microcystin (MC) variants. More importantly, this method was successfully used for the quantitative analysis of microcystins (MCs) in crude algae samples from natural water bodies, making it promising for practical applications.
Collapse
Affiliation(s)
- Ping Yan
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, P. R. China
| | - Keke Zhang
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, P. R. China
| | - Lingyu Wang
- Department of Chemistry, University of British Columbia, Vancouver, BC, Canada
| | - Wenjun Tong
- Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Jiangsu Key Laboratory of Biomedical Materials, School of Chemistry and Materials Science, Nanjing Normal University, Nanjing, P. R. China
| | - David D Y Chen
- Department of Chemistry, University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|
6
|
Derivatization reagent-assisted enantioseparation of 3-hydroxyaspartate with two chiral centers in rat cerebrospinal fluid by capillary electrophoresis-mass spectrometry. Anal Chim Acta 2018; 1047:257-266. [PMID: 30567658 DOI: 10.1016/j.aca.2018.09.070] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2018] [Accepted: 09/28/2018] [Indexed: 11/23/2022]
Abstract
A new analytical method based on capillary zone electrophoresis-mass spectrometry (CZE-MS) was proposed and validated for the simultaneous determination of four stereoisomers of 3-hydroxyaspartate with two chiral centers in rat cerebrospinal fluid (CSF) in absence of optically pure single enantiomer standards. The derivatization reagent 9-fluorenylmethyl chloroformate (FMOC-Cl) was found to assist chiral separation and the derivatized enantiomers of 3-hydroxyaspartate can achieve enantioseparation with a lower concentration (6 mM) of β-cyclodextrin (β-CD), while underivatized 3-hydroxyaspartate cannot be separated. The enhanced interactions between derivatized analytes and β-CD were demonstrated by proton nuclear magnetic resonance (1H NMR). The four stereoisomers of FMOC-3-hydroxyaspartate were identified successfully using a new method based on experimental and calculated electronic circular dichroism (ECD) spectra combined with the comparison of CE peak areas. Large volume sample stacking with polarity switching (LVSS-PS) was used to increase sensitivity and the detection limit of 356 nM was achieved for L-THA, which was around 10-fold improvement compared to the normal CE-MS analysis. The composition of the background electrolyte (BGE) was optimized by response surface methodology (RSM). Under the optimal conditions, satisfactory results of L-THA were obtained in terms of linearity over the range of 2-80 μM (R2 > 0.99) and precision (RSD below 1.43% and 2.56% for migration time and peak area, respectively). The recoveries for all four stereoisomers in spiked rat CSF ranged from 91.2% to 99.5%. The method has been successfully applied to rat CSF analysis and D-erythro-3-hydroxyaspartate (D-EHA) was detected.
Collapse
|
7
|
A Comprehensive Guide for Performing Sample Preparation and Top-Down Protein Analysis. Proteomes 2017; 5:proteomes5020011. [PMID: 28387712 PMCID: PMC5489772 DOI: 10.3390/proteomes5020011] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2016] [Revised: 04/04/2017] [Accepted: 04/04/2017] [Indexed: 12/21/2022] Open
Abstract
Methodologies for the global analysis of proteins in a sample, or proteome analysis, have been available since 1975 when Patrick O′Farrell published the first paper describing two-dimensional gel electrophoresis (2D-PAGE). This technique allowed the resolution of single protein isoforms, or proteoforms, into single ‘spots’ in a polyacrylamide gel, allowing the quantitation of changes in a proteoform′s abundance to ascertain changes in an organism′s phenotype when conditions change. In pursuit of the comprehensive profiling of the proteome, significant advances in technology have made the identification and quantitation of intact proteoforms from complex mixtures of proteins more routine, allowing analysis of the proteome from the ‘Top-Down’. However, the number of proteoforms detected by Top-Down methodologies such as 2D-PAGE or mass spectrometry has not significantly increased since O’Farrell’s paper when compared to Bottom-Up, peptide-centric techniques. This article explores and explains the numerous methodologies and technologies available to analyse the proteome from the Top-Down with a strong emphasis on the necessity to analyse intact proteoforms as a better indicator of changes in biology and phenotype. We arrive at the conclusion that the complete and comprehensive profiling of an organism′s proteome is still, at present, beyond our reach but the continuing evolution of protein fractionation techniques and mass spectrometry brings comprehensive Top-Down proteome profiling closer.
Collapse
|
8
|
Ortiz-Villanueva E, Benavente F, Giménez E, Yilmaz F, Sanz-Nebot V. Preparation and evaluation of open tubular C18-silica monolithic microcartridges for preconcentration of peptides by on-line solid phase extraction capillary electrophoresis. Anal Chim Acta 2014; 846:51-9. [DOI: 10.1016/j.aca.2014.06.046] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2014] [Revised: 05/28/2014] [Accepted: 06/26/2014] [Indexed: 10/25/2022]
|
9
|
Buzatto AZ, de Sousa AC, Guedes SF, Cieslarová Z, Simionato AVC. Metabolomic investigation of human diseases biomarkers by CE and LC coupled to MS. Electrophoresis 2014; 35:1285-307. [PMID: 24375663 DOI: 10.1002/elps.201300470] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Revised: 12/18/2013] [Accepted: 12/19/2013] [Indexed: 12/13/2022]
Abstract
Metabolomics is one of the most recent trends in the "omics" era that investigates the end products of an organism activity, that is, all metabolites in a biological system, which are small molecules (less than 1000 Da) from different chemical classes. Metabolomics represents a tool to assess the biochemical activity of a living system through the analysis of substrates and products processed during the metabolism. The analysis of the metabolic profile (nontargeted analysis, i.e. a comparison between samples profiles of individuals) and of specific metabolites (targeted analysis, which quantifies a selected group of metabolites) in biological samples provides an insight into the metabolic state and the biochemical processes of the organism and, therefore, may indicate the onset and the stage of different diseases. An early and accurate diagnosis is essential for successful treatment and probable cure of most illnesses; hence, the investigation of metabolites as disease biomarkers has increased considerably in recent years. This review aims to present the most relevant works that address the nontargeted and targeted analysis of metabolites in different diseases for the past 10 years, including kidney and neurological disorders, cardiovascular diseases, diabetes, and cancer, using CE and LC coupled with the accurate detection of mass spectroscopy.
Collapse
Affiliation(s)
- Adriana Z Buzatto
- Institute of Chemistry, University of Campinas - Unicamp, Campinas, Brazil
| | | | | | | | | |
Collapse
|
10
|
Chen Q, Zhang W, Zhang Y, Chen J, Chen Z. Identification and quantification of active alkaloids in Catharanthus roseus by liquid chromatography–ion trap mass spectrometry. Food Chem 2013; 139:845-52. [DOI: 10.1016/j.foodchem.2013.01.088] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2012] [Revised: 10/31/2012] [Accepted: 01/28/2013] [Indexed: 11/29/2022]
|
11
|
Rodríguez J, Castañeda G, Muñoz L. Direct determination of pregabalin in human urine by nonaqueous CE-TOF-MS. Electrophoresis 2013; 34:1429-36. [DOI: 10.1002/elps.201200564] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2012] [Revised: 01/23/2013] [Accepted: 01/24/2013] [Indexed: 11/09/2022]
Affiliation(s)
- Juana Rodríguez
- Department of Analytical Chemistry and Food Technology; University of Castilla-La Mancha; Ciudad Real; Spain
| | - Gregorio Castañeda
- Department of Analytical Chemistry and Food Technology; University of Castilla-La Mancha; Ciudad Real; Spain
| | - Lorena Muñoz
- Department of Analytical Chemistry and Food Technology; University of Castilla-La Mancha; Ciudad Real; Spain
| |
Collapse
|
12
|
Chen Q, Zhang J, Zhang W, Chen Z. Analysis of active alkaloids in the Menispermaceae family by nonaqueous capillary electrophoresis-ion trap mass spectrometry. J Sep Sci 2012; 36:341-9. [PMID: 23255368 DOI: 10.1002/jssc.201200678] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2012] [Revised: 09/23/2012] [Accepted: 09/26/2012] [Indexed: 11/11/2022]
Abstract
A nonaqueous CE-IT MS with a nanospray ionization interface method was developed for the identification and quantification of tetrandrine (TET), fangchinoline (FAN), and sinomenine (SIN) using berberine as internal standard. The TET, FAN, and SIN standard solutions were directly infused into IT-MS for collecting MS(1-3) spectra. The major fragment ions of analytes were confirmed and possible main cleavage pathways of fragment ions were studied. A bare fused-silica capillary was used for separation of the analytes. A sheath liquid (50% aqueous methanol containing 0.2% acetic acid) to the capillary effluent with a nanoelectrospray ionization interface was added. Separation buffer comprised 80 mM solution of ammonium acetate, in a mixture of 70% methanol, 20% ACN, and 10% water, which also contained 1% acetic acid. The CE-MS method was validated for linearity, sensitivity, accuracy, and precision, and then used to determine the content of the above components. The detection limits of TET, FAN, and SIN are 0.05, 0.08, and 0.15 μg/mL, respectively. The precision was no more than 4.67% and the mean recovery of the analytes were 95.36-99.24%. This method was successfully applied to determine TET, FAN, and SIN in real samples radix Stephaniae tetrandrae and rhizomes of Menispermum dauricum.
Collapse
Affiliation(s)
- Qinhua Chen
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, School of Pharmaceutical Sciences, Wuhan University, Wuhan, China
| | | | | | | |
Collapse
|
13
|
Tie C, Zhang DW, Chen HX, Song SL, Zhang XX. Study of the electrical connection mechanism of sheathless interface for capillary electrophoresis-electrospray ionization-mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2012; 47:1429-1434. [PMID: 23147818 DOI: 10.1002/jms.3077] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
With the combination of high separation ability of capillary electrophoresis (CE) and strong identification ability of mass spectrometry (MS), CE/MS is becoming a powerful tool for polar and ionic analytes analysis. Different interfaces have been developed to enhance the sensitivity and reliability since the first introduction of CE/MS in 1987. A sheathless porous interface based on a new ions transferring electric connection technique was reported to be with high sensitivity and reliability. In this work, a series of optical and electrochemical experiments were designed to study the electric connection process. The results indicated that closing CE electrical circuit and applying MS spray voltage were achieved by the small ions transferring through the interface porous wall. The new electric connection method significantly enhanced the sensitivity, resolution and stability of the CE/MS analysis. The interface was applied in CE/MS detection of morphine and 6-monoacetylmorphine in urine sample and showed an equal sensitivity to LC/MS. With the significant improvement of sensitivity and stability, the CE/MS with the new interface showed strong potential for the determination of low abundance analytes.
Collapse
Affiliation(s)
- Cai Tie
- Beijing National Laboratory for Molecular Sciences (BNLMS), Key Laboratory of Biochemistry and Molecular Engineering of Ministry of Education, College of Chemistry, Peking University, Beijing, China
| | | | | | | | | |
Collapse
|
14
|
Zhao SS, Zhong X, Tie C, Chen DD. Capillary electrophoresis-mass spectrometry for analysis of complex samples. Proteomics 2012; 12:2991-3012. [DOI: 10.1002/pmic.201200221] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2012] [Revised: 07/10/2012] [Accepted: 07/18/2012] [Indexed: 12/20/2022]
Affiliation(s)
- Shuai Sherry Zhao
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| | - Xuefei Zhong
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| | - Cai Tie
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| | - David D.Y. Chen
- Department of Chemistry; University of British Columbia; Vancouver BC Canada
| |
Collapse
|
15
|
Lin SL, Bai HY, Lin TY, Fuh MR. Microfluidic chip-based liquid chromatography coupled to mass spectrometry for determination of small molecules in bioanalytical applications. Electrophoresis 2012; 33:635-43. [PMID: 22451056 DOI: 10.1002/elps.201100380] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The development and integration of microfabricated liquid chromatography (LC) microchips have increased dramatically in the last decade due to the needs of enhanced sensitivity and rapid analysis as well as the rising concern on reducing environmental impacts of chemicals used in various types of chemical and biochemical analyses. Recent development of microfluidic chip-based LC mass spectrometry (chip-based LC-MS) has played an important role in proteomic research for high throughput analysis. To date, the use of chip-based LC-MS for determination of small molecules, such as biomarkers, active pharmaceutical ingredients (APIs), and drugs of abuse and their metabolites, in clinical and pharmaceutical applications has not been thoroughly investigated. This mini-review summarizes the utilization of commercial chip-based LC-MS systems for determination of small molecules in bioanalytical applications, including drug metabolites and disease/tumor-associated biomarkers in clinical samples as well as adsorption, distribution, metabolism, and excretion studies of APIs in drug discovery and development. The different types of commercial chip-based interfaces for LC-MS analysis are discussed first and followed by applications of chip-based LC-MS on biological samples as well as the comparison with other LC-MS techniques.
Collapse
Affiliation(s)
- Shu-Ling Lin
- Department of Chemistry, Soochow University, Taipei, Taiwan
| | | | | | | |
Collapse
|
16
|
Espada A, Molina-Martin M. Capillary electrophoresis and small molecule drug discovery: a perfect match? Drug Discov Today 2012; 17:396-404. [PMID: 22387356 DOI: 10.1016/j.drudis.2012.02.008] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2011] [Revised: 12/19/2011] [Accepted: 02/10/2012] [Indexed: 01/27/2023]
Abstract
Capillary electrophoresis (CE) is an analytical technique based on the separation of the analytes within a capillary owing to their different electrophoretic mobilities. It is widely used in pharmaceutical analyses owing to its versatility and high separation power. However, its penetration into the drug discovery scene has been relatively limited until recent years. Several factors have contributed to this low implementation, including the maturity of liquid chromatography, the scarcity of experienced CE practitioners, and certain limitations intrinsic to the technique. Recently, instrumental improvements and the growing demand for analytical information have lead to a continuously expanding range of routine electrophoretic applications throughout pharmaceutical discovery and development. In this article we review CE fundamentals, review well-established CE methodologies in drug discovery of small molecules and discuss trends that, in our opinion, might emerge in the coming years.
Collapse
Affiliation(s)
- Alfonso Espada
- Analytical Technologies Department, Centro de Investigación Lilly SA, Avda de la Industria 30, 28108-Alcobendas, Madrid, Spain
| | | |
Collapse
|
17
|
Li T, Booker CJ, Yeung KKC. Migration behaviour of discontinuous buffers in capillary electrophoresis during protein enrichment. Analyst 2012; 137:4766-73. [DOI: 10.1039/c2an35548e] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
18
|
Removal of sample background buffering ions and myoglobin enrichment via a pH junction created by discontinuous buffers in capillary electrophoresis. J Chromatogr A 2011; 1218:5705-11. [DOI: 10.1016/j.chroma.2011.06.054] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2011] [Revised: 06/01/2011] [Accepted: 06/13/2011] [Indexed: 01/04/2023]
|
19
|
Chen Q, Li N, Zhang W, Chen J, Chen Z. Simultaneous determination of vinblastine and its monomeric precursors vindoline and catharanthine in Catharanthus roseus by capillary electrophoresis-mass spectrometry. J Sep Sci 2011; 34:2885-92. [PMID: 21735550 DOI: 10.1002/jssc.201100359] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2011] [Revised: 06/02/2011] [Accepted: 06/02/2011] [Indexed: 11/09/2022]
Abstract
Catharanthus roseus is an important dicotyledonous medicinal plant that contains various anticancer components, such as vinblastine (VLB) and its monomeric precursors (vindoline and catharanthine). A capillary electrophoresis-mass spectrometry (CE-MS) approach for the simultaneous determination of three components was developed in this work. Baseline separation for three components was achieved by using a running buffer consisting of 20 mM ammonium acetate and 1.5% acetic acid in <20 min. Quantification of three components was assigned in positive-ion mode at a protonated molecular ion [M+H](+). The CE-MS method was validated for linearity, sensitivity, accuracy and precision, and then used to determine the content of the above components. The detection limits of VLB, catharanthine and vindoline are 0.8, 0.1 and 0.1 μg/mL, respectively. The precision was not more than 4.54% and the mean recovery of the analytes was 95.04-97.04%. The CE-MS method was successfully applied to determine VLB and its monomeric precursors in real sample C. roseus.
Collapse
Affiliation(s)
- Qinhua Chen
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery (Wuhan University), Ministry of Education, and Wuhan University School of Pharmaceutical Sciences, Wuhan, PR China
| | | | | | | | | |
Collapse
|
20
|
Medina-Casanellas S, Benavente F, Barbosa J, Sanz-Nebot V. Transient isotachophoresis in on-line solid phase extraction capillary electrophoresis time-of-flight-mass spectrometry for peptide analysis in human plasma. Electrophoresis 2011; 32:1750-9. [DOI: 10.1002/elps.201100017] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
21
|
Simionato AVC, Carrilho E, Tavares MFM. Characterization of protein hydrolysates of cosmetic use by CE-MS. J Sep Sci 2011; 34:947-56. [PMID: 21374808 DOI: 10.1002/jssc.201000677] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2010] [Revised: 01/24/2011] [Accepted: 01/25/2011] [Indexed: 12/28/2022]
Abstract
Protein hydrolysates have been used as active principles in cosmetic products conferring different properties to the final formulations, which are mostly controlled by the peptide size and its amino acid sequence. In this work, capillary electrophoresis coupled to mass spectrometry analyses were carried out in order to investigate such characteristics of protein hydrolysates. Samples of different origins (milk, soy and rice) were obtained from a local company, and were analyzed without a previous preparation step. The background electrolyte (BGE) and sheath liquid compositions were optimized for each sample. The best BGE composition (860 mmol/L formic acid--pH 1.8--in 70:30 v/v water/methanol hydro-organic solvent) was chosen based on the overall peak resolution whereas the best sheath liquid was selected based on increased sensitivity and presented different compositions to each sample (10.9-217 mmol/L formic acid in 75:25-25:75 v/v water/methanol hydro-organic solvent). Most of the putative peptides in the hydrolysate samples under investigation presented molecular masses of 1000 Da or less. De novo sequencing was carried out for some of the analytes, revealing the hydrophobicity/polarity of the peptides. Hence, the technique has proved to be an advantageous tool for the quality control of industrial protein hydrolysates.
Collapse
|
22
|
Quirino JP. Sweeping of neutral analytes in partial-filling micellar electrokinetic chromatography with electrospray ionization mass spectrometry. Electrophoresis 2011; 32:665-8. [DOI: 10.1002/elps.201000513] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2010] [Revised: 11/15/2010] [Accepted: 11/27/2010] [Indexed: 11/08/2022]
|
23
|
de la Guardia M, Armenta S. Multianalyte Determination Versus One-at-a-Time Methodologies. GREEN ANALYTICAL CHEMISTRY 2011. [DOI: 10.1016/b978-0-444-53709-6.00006-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
24
|
Pantůčková P, Gebauer P, Boček P, Křivánková L. Recent advances in CE-MS: Synergy of wet chemistry and instrumentation innovations. Electrophoresis 2010; 32:43-51. [PMID: 21171112 DOI: 10.1002/elps.201000382] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2010] [Revised: 08/17/2010] [Accepted: 08/17/2010] [Indexed: 01/29/2023]
Abstract
CE with MS detection is a hyphenated technique which greatly improves the ability of CE to deal with real samples, especially with those coming from biology and medicine, where the target analytes are present as trace amounts in very complex matrices. CE-MS is now almost a routine technique performed on commercially available instruments. It faces currently a tremendous development of the technique itself as well as of its wide application area. Great interest in CE-MS is reflected in the scientific literature by many original research articles and also by numerous reviews. The review presented here has a general scope and belongs to a series of regularly published reviews on the topic. It covers the literature from the last 2 years, since January 2008 till June 2010. It brings a critical selection of related literature sorted into groups reflecting the main topics of actual scientific interest: (i) innovations in CE-ESI-MS, (ii) use of alternative interfaces, and (iii) ways to enhance sensitivity. Special attention is paid to novel electrolyte systems amenable to CE-MS including nonvolatile BGEs, to advanced CE separation principles such as MEKC, MEEKC, chiral CE, and to the use of preconcentration techniques.
Collapse
Affiliation(s)
- Pavla Pantůčková
- Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic, Brno, Czech Republic
| | | | | | | |
Collapse
|
25
|
Kitagawa F, Otsuka K. Recent progress in microchip electrophoresis-mass spectrometry. J Pharm Biomed Anal 2010; 55:668-78. [PMID: 21130595 DOI: 10.1016/j.jpba.2010.11.013] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2010] [Revised: 11/10/2010] [Accepted: 11/10/2010] [Indexed: 01/30/2023]
Abstract
This review highlights the methodological and instrumental developments in microchip electrophoresis (MCE)-mass spectrometry (MS) from 1997. In MCE-MS, the development of ionization interface is one of the most important issues to realize highly sensitive detection and high separation efficiency. Among several interfaces, electrospray ionization (ESI) has been mainly employed to MCE-MS since a simple structure of the ESI interface is suitable for coupling with the microchips. Although the number of publications is still limited, laser desorption ionization (LDI) interface has also been developed for MCE-MS. The characteristics of the ESI and LDI interfaces applied to the electrophoresis microchips are presented in this review. The scope of applications in MCE-MS covers mainly biogenic compounds such as bioactive amines, peptides, tryptic digests and proteins. This review provides a comprehensive table listing the applications in MCE-MS.
Collapse
Affiliation(s)
- Fumihiko Kitagawa
- Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8510, Japan.
| | | |
Collapse
|
26
|
Sasajima Y, Lim LW, Takeuchi T, Suenami K, Sato K, Takekoshi Y. Simultaneous determination of antidepressants by non-aqueous capillary electrophoresis-time of flight mass spectrometry. J Chromatogr A 2010; 1217:7598-604. [DOI: 10.1016/j.chroma.2010.10.003] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2010] [Revised: 09/29/2010] [Accepted: 10/01/2010] [Indexed: 11/16/2022]
|
27
|
Jecklin MC, Schmid S, Urban PL, Amantonico A, Zenobi R. Miniature flowing atmospheric-pressure afterglow ion source for facile interfacing of CE with MS. Electrophoresis 2010; 31:3597-605. [DOI: 10.1002/elps.201000350] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
28
|
Analysis of microcystins by capillary zone electrophoresis coupling with electrospray ionization mass spectrometry. Talanta 2010; 82:1101-6. [DOI: 10.1016/j.talanta.2010.05.045] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2010] [Revised: 05/16/2010] [Accepted: 05/18/2010] [Indexed: 11/21/2022]
|
29
|
Wojcik R, Dada OO, Sadilek M, Dovichi NJ. Simplified capillary electrophoresis nanospray sheath-flow interface for high efficiency and sensitive peptide analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2010; 24:2554-60. [PMID: 20740530 DOI: 10.1002/rcm.4672] [Citation(s) in RCA: 190] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
We report a simple nanospray sheath-flow interface for capillary electrophoresis. This interface relies on electrokinetic flow to drive both the separation and the electrospray; no mechanical pump is used for the sheath flow. This system was interfaced with an LCQ mass spectrometer. The best results were observed with a 2-microm diameter emitter tip and a 1-mm spacing between the separation capillary tip and the emitter tip. Under these conditions, mass detection limits (3sigma) of 100 amol were obtained for insulin receptor fragment 1142-1153. The separation efficiency exceeded 200,000 plates for this compound. The relative standard deviation generated during continual infusion of a 50 microM solution of angiotensin II was 2% for the total ion count and 3% for the extracted ion count over a 40-min period. Finally, the interface was also demonstrated for negative ion mode.
Collapse
Affiliation(s)
- Roza Wojcik
- Department of Chemistry, University of Washington, Seattle, WA 98195-1700, USA
| | | | | | | |
Collapse
|
30
|
Felhofer JL, Blanes L, Garcia CD. Recent developments in instrumentation for capillary electrophoresis and microchip-capillary electrophoresis. Electrophoresis 2010; 31:2469-86. [PMID: 20665910 PMCID: PMC2928674 DOI: 10.1002/elps.201000203] [Citation(s) in RCA: 67] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Over the last years, there has been an explosion in the number of developments and applications of CE and microchip-CE. In part, this growth has been the direct consequence of recent developments in instrumentation associated with CE. This review, which is focused on the contributions published in the last 5 years, is intended to complement the articles presented in this special issue dedicated to instrumentation and to provide an overview of the general trends and some of the most remarkable developments published in the areas of high-voltage power supplies, detectors, auxiliary components, and compact systems. It also includes a few examples of alternative uses of and modifications to traditional CE instruments.
Collapse
Affiliation(s)
- Jessica L. Felhofer
- Department of Chemistry, The University of Texas at San Antonio, One UTSA Circle, San Antonio, TX 78249, United States of America
| | - Lucas Blanes
- Centre for Forensic Science, University of Technology, Sydney, PO Box 123, Broadway, NSW 2007, Australia
| | - Carlos D. Garcia
- Department of Chemistry, The University of Texas at San Antonio, One UTSA Circle, San Antonio, TX 78249, United States of America
| |
Collapse
|
31
|
Benavente F, Medina-Casanellas S, Barbosa J, Sanz-Nebot V. Investigation of commercial sorbents for the analysis of opioid peptides in human plasma by on-line SPE-CE. J Sep Sci 2010; 33:1294-304. [PMID: 20187028 DOI: 10.1002/jssc.200900669] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
In this study, we investigated the performance of several commercial sorbents (Sep-pack) C18, (t)C18, C8 and (t)C2, Oasis HLB, Isolute ENV+, Strata-X and Oasis MCX) for the determination of opioid peptides by solid-phase extraction coupled on-line to capillary electrophoresis (SPE-CE). First, standard solutions were analyzed in order to achieve the lowest LOD and the best electrophoretic separations using UV detection. The best results were obtained using C18, C8 and (t)C2 sorbents, which were examined for the analysis of spiked human plasma samples. A double-step sample clean-up pretreatment, which consisted of precipitation with acetonitrile and filtration, was needed to prevent saturation of the on-line SPE microcartridge. The filtration step was critical to obtain optimum analyte recovery and to clean up the sample matrix. A range of centrifugal filters and filtration conditions were tested and the recoveries of the sample pretreatment were evaluated by CE-ESI-MS. The LODs attained through SPE-CE-UV were approximately ten-fold better with C18 than with C8 and (t)C2. The 0.1 microg/mL LODs achieved by C18-SPE-CE-UV were further improved until we could detect 1 ng/mL concentrations of opioid peptides in plasma samples by C18-SPE-CE-ESI-MS, due to the outstanding selectivity of the MS detection.
Collapse
Affiliation(s)
- Fernando Benavente
- Department of Analytical Chemistry, University of Barcelona, Barcelona, Spain.
| | | | | | | |
Collapse
|
32
|
Herrero M, García-Cañas V, Simo C, Cifuentes A. Recent advances in the application of capillary electromigration methods for food analysis and Foodomics. Electrophoresis 2010; 31:205-28. [PMID: 19967713 DOI: 10.1002/elps.200900365] [Citation(s) in RCA: 142] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The use of capillary electromigration methods to analyze foods and food components is reviewed in this work. Papers that were published during the period April 2007 to March 2009 are included following the previous review by García-Cañas and Cifuentes (Electrophoresis, 2008, 29, 294-309). These works include the analysis of amino acids, biogenic amines, peptides, proteins, DNAs, carbohydrates, phenols, polyphenols, pigments, toxins, pesticides, vitamins, additives, small organic and inorganic ions and other compounds found in foods and beverages, as well as those applications of CE for monitoring food interactions and food processing. The use of microchips, CE-MS, chiral-CE as well as other foreseen trends in food analysis are also discussed including their possibilities in the very new field of Foodomics.
Collapse
Affiliation(s)
- Miguel Herrero
- Departamento de Caracterización de Alimentos, Instituto de Fermentaciones Industriales, Madrid 28006, Spain
| | | | | | | |
Collapse
|
33
|
Guihen E, O'Connor WT. Capillary and microchip electrophoresis in microdialysis: recent applications. Electrophoresis 2010; 31:55-64. [PMID: 20039293 DOI: 10.1002/elps.200900467] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The theme of this review is to highlight the importance of microscale electrophoretic-based separation systems in microdialysis (microD). The ability of CE and MCE to yield very rapid and highly efficient separations using just nanolitre volumes of microdialysate samples will also be discussed. Recent advances in this area will be highlighted, by illustration of some exciting new applications while the need for further innovation will be covered. The first section briefly introduces the concept of microD sampling coupled with electrophoresis-based separation and the inherent advantages of this approach. The following section highlights some specific applications of CE separations in the detection of important biomarkers such as low-molecular-weight neurotransmitters, amino acids, and other molecules that are frequently encountered in microD. Various detection modes in CE are outlined and some of the advantages and drawbacks thereof are discussed. The last section introduces the concepts of micro-total analysis systems and the coupling of MCE and microD. Some of the latest innovations will be illustrated. The concluding section reflects on the future of this important chemical alliance between microD and CE/MCE.
Collapse
Affiliation(s)
- Elizabeth Guihen
- Graduate Entry Medical School and Materials and Surface Science Institute, University of Limerick, Limerick, Ireland.
| | | |
Collapse
|
34
|
|
35
|
|
36
|
Guihen E, O'Connor WT. Current separation and detection methods in microdialysis the drive towards sensitivity and speed. Electrophoresis 2009; 30:2062-75. [PMID: 19582708 DOI: 10.1002/elps.200900039] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
This review outlines some of the analytical challenges associated with the analysis of microdialysis (MD) samples, in particular, the minute complex sample volumes that are often encountered. In MD sampling many different low-molecular-weight molecules can be collected, but the research findings are often limited by the sensitivity, specificity, and reliability of the analytical technique that is coupled to the dialysis probe. Therefore it is critical that a lot of consideration is given in selecting the most suitable analytical method including the most appropriate detector. This review aims to highlight the strengths and weaknesses of a range of commonly used analytical methods employed in MD. In Section 1, a brief overview of the MD technique is described, followed by a discussion on some of the advantages and drawbacks of this sampling technique. Sections 2 and 3 examine analytical and other technical considerations regarding analysis, with special emphasis on the factors that specifically influence analytical detection. Section 4 outlines the most commonly employed analytical techniques used in MD, including HPLC coupled with various detectors. Detail is given regarding the LOD and LOQ for many applications using each detector. As MS is of such high importance in MD, a special sub-section has been devoted to it. The importance of CE is also highlighted, with specific applications described. In addition, analytical techniques that do not appear to have found routine use in MD are discussed. Section 5 is concerned with recent innovations in chemical separation techniques, in particular MCE and ultra-performance liquid chromatography. Specific applications of the coupling of these techniques with MD are highlighted, along with technical challenges associated with miniaturization. In the Section 6, the future outlook of MD is discussed. Techniques other than electrophoretic- and chromatographic based separation methods are outside the scope of this review.
Collapse
Affiliation(s)
- Elizabeth Guihen
- Graduate Entry Medical School and Material Surface Science Institute, University of Limerick, Limerick, Ireland.
| | | |
Collapse
|
37
|
Klampfl CW. CE with MS detection: A rapidly developing hyphenated technique. Electrophoresis 2009; 30 Suppl 1:S83-91. [DOI: 10.1002/elps.200900088] [Citation(s) in RCA: 84] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
38
|
Jarussophon S, Acoca S, Gao JM, Deprez C, Kiyota T, Draghici C, Purisima E, Konishi Y. Automated molecular formula determination by tandem mass spectrometry (MS/MS). Analyst 2009; 134:690-700. [PMID: 19305917 DOI: 10.1039/b818398h] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Automated software was developed to analyze the molecular formula of organic molecules and peptides based on high-resolution MS/MS spectroscopic data. The software was validated with 96 compounds including a few small peptides in the mass range of 138-1569 Da containing the elements carbon, hydrogen, nitrogen and oxygen. A Micromass Waters Q-TOF Ultima Global mass spectrometer was used to measure the molecular masses of precursor and fragment ions. Our software assigned correct molecular formulas for 91 compounds, incorrect molecular formulas for 3 compounds, and no molecular formula for 2 compounds. The obtained 95% success rate indicates high reliability of the software. The mass accuracy of the precursor ion and the fragment ions, which is critical for the success of the analysis, was high, i.e. the accuracy and the precision of 850 data were 0.0012 Da and 0.0016 Da, respectively. For the precursor and fragment ions below 500 Da, 60% and 90% of the data showed accuracy within < or = 0.001 Da and < or = 0.002 Da, respectively. The precursor and fragment ions above 500 Da showed slightly lower accuracy, i.e. 40% and 70% of them showed accuracy within < or = 0.001 Da and < or = 0.002 Da, respectively. The molecular formulas of the precursor and the fragments were further used to analyze possible mass spectrometric fragmentation pathways, which would be a powerful tool in structural analysis and identification of small molecules. The method is valuable in the rapid screening and identification of small molecules such as the dereplication of natural products, characterization of drug metabolites, and identification of small peptide fragments in proteomics. The analysis was also extended to compounds that contain a chlorine or bromine atom.
Collapse
Affiliation(s)
- Suwatchai Jarussophon
- Biotechnology Research Institute, National Research Council Canada, 6100 Royalmount Avenue, Montréal, Québec, Canada H4P 2R2
| | | | | | | | | | | | | | | |
Collapse
|