Liu Y, Bai J, Dong X, Cao Y, Bao M, Lu Y, Zeng H, Zhan L, Guo Y. Online Charge-Generation Derivatization by Electrochemical Radical Cations of Thianthrene: Mass Spectrometry Imaging of Estrogens in Biological Tissues. Anal Chem 2024. [PMID: 39031066 DOI: 10.1021/acs.analchem.4c02086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/22/2024]
Abstract
Estrogens play a significant role in endocrinology and oncology. Although separation methods coupled with mass spectrometry (MS) have emerged as a powerful tool for studying estrogens, imaging the spatial distributions of estrogens is crucial but remains challenging due to its low endogenous concentration and poor ionization efficiency. Charge-generation derivatization, such as N-alkylpyridinium quaternization and S-methyl thioetherification, represents a method wherein neutral molecules involving analytes and derivatization reagents undergo chemical reactions to establish permanent charges directly onto the analytes to improve detection sensitivity. Here, we developed a novel derivatization reagent, thianthrene (TT), which enabled oxidization to radical cations ([TT]•+) using an electrochemical method and completed the online charge-generation derivatization of estrogens on a mass spectrometry imaging platform. In this strategy, [TT]•+ can efficiently and selectively derivatize estrogens via an electrophilic aromatic substitution reaction. Results indicated that derivatization with [TT]•+ can significantly enhance imaging sensitivity (3 orders of magnitude), enabling the visualization of estrogen and its metabolites in ovarian and breast tissues. Furthermore, a higher mass intensity of these estrogens was captured in breast para-cancerous tissues than in cancerous tissues, which might provide estrogens spatial dimension information for further research on the initiation and progression of breast cancer.
Collapse
Affiliation(s)
- Yingchao Liu
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, Shanghai 200032, China
| | - Jiahui Bai
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, Shanghai 200032, China
| | - Xiaoxia Dong
- CAS Key Laboratory of Nutrition, Metabolism and Food Safety, Shanghai Institute of Nutrition and Health, University of Chinese Academy of Sciences, Chinese Academy of Sciences, Shanghai 200031, China
| | - Yuqi Cao
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, Shanghai 200032, China
| | - Mingmai Bao
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, Shanghai 200032, China
| | - Yingjie Lu
- Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai 201203, China
| | - Hui Zeng
- Comprehensive Exposure Research Center, School of Pharmacy, Liaoning University of Traditional Chinese Medicine, Dalian 116600, China
| | - Lixing Zhan
- CAS Key Laboratory of Nutrition, Metabolism and Food Safety, Shanghai Institute of Nutrition and Health, University of Chinese Academy of Sciences, Chinese Academy of Sciences, Shanghai 200031, China
| | - Yinlong Guo
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, University of Chinese Academy of Sciences, Chinese Academy of Sciences, Shanghai 200032, China
| |
Collapse
|
2
|
Liu Y, Wang X, Wei J, Fu K, Chen Y, Li L, Wang Z, Yang L. Comprehensive profiling of amino acids and derivatives in biological samples: A robust UHPLC-MS/MS method for investigating acute lung injury. J Chromatogr A 2024; 1721:464816. [PMID: 38537486 DOI: 10.1016/j.chroma.2024.464816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 03/10/2024] [Accepted: 03/12/2024] [Indexed: 04/13/2024]
Abstract
The severe respiratory dysfunctions associated with acute lung injury (ALI) and its sequelae have a high morbidity and mortality rate, are multifactorial, and lack a viable treatment. Considering the critical function that amino acids and derivatives play in the genesis of illnesses and the regulation of metabolic processes, monitoring the levels of metabolites associated with amino acids in biological matrices is necessary and interesting to study their pathological mechanisms. Exploring the dynamics of amino acids and derivatives level and searching for biomarkers provides improved clinical ideas for the diagnosis and treatment of ALI. Therefore, we developed an ultra-high-performance liquid chromatography-electrospray tandem mass spectrometry (UHPLC-MS/MS) method that can simultaneously determine the amino acid and derivatives metabolic levels to study amino acid profiles in different biological samples to facilitate clinical research of ALI. In this study, 48 amino acids and derivatives, including neurotransmitters, polyamines, purines, and other types, were quantified simultaneously in a fast, high-throughput, sensitive, and reliable manner within a 15-minute run time without derivatization. No relevant studies have been reported to quantify these 48 amino acid metabolites in three biological samples simultaneously. Satisfactory linearity (R > 0.995), inter-day and intra-day accuracy (85.17-112.67 % and 85.29-111.60 %, respectively), inter-day and intra-day precision (RSD < 13.80 % and RSD < 12.01 %, respectively), matrix effects (81.00 %-118.00 %), recovery (85.09 %-114.65 %) and stability (RSD < 14.72 %) were all demonstrated by the optimized method's successful validation for all analytes. In addition, the suggested method was effectively implemented in plasma, urine, and lung tissue from normal mice and mice with ALI, with the aim of finding potential biomarkers associated with ALI. Potential biomarkers were screened through multivariate statistical analysis and volcanic map analysis, and the changes of markers in ALI were again identified through heat map analysis and correlation analysis with biochemical indicators, which provided ideas and references for subsequent mechanism studies. Here, the technique created in this work offers a quick and dependable way to perform an integrated analysis of amino acids in a variety of biological materials, which can provide research ideas for understanding the physiopathological state of various diseases.
Collapse
Affiliation(s)
- Yamin Liu
- The MOE Key Laboratory of Standardization of Chinese Medicines, the SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicine, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Xunjiang Wang
- The MOE Key Laboratory of Standardization of Chinese Medicines, the SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicine, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Jiaojiao Wei
- The MOE Key Laboratory of Standardization of Chinese Medicines, the SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicine, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Kangning Fu
- The MOE Key Laboratory of Standardization of Chinese Medicines, the SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicine, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Yilin Chen
- The MOE Key Laboratory of Standardization of Chinese Medicines, the SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicine, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China
| | - Linnan Li
- The MOE Key Laboratory of Standardization of Chinese Medicines, the SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicine, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
| | - Zhengtao Wang
- The MOE Key Laboratory of Standardization of Chinese Medicines, the SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicine, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
| | - Li Yang
- The MOE Key Laboratory of Standardization of Chinese Medicines, the SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Shanghai Key Laboratory of Compound Chinese Medicine, Institute of Chinese Materia Medica, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.
| |
Collapse
|
3
|
Gao S, Zhou X, Yue M, Zhu S, Liu Q, Zhao XE. Advances and perspectives in chemical isotope labeling-based mass spectrometry methods for metabolome and exposome analysis. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/16/2023]
|
4
|
Bu XM, Zhao WD, Zhang MY, Wu DQ, Wu JY, Xu X, Chen D. Matrix-assisted laser desorption/ionization high-resolution mass spectrometry for high-throughput analysis of androgenic steroid adulteration in traditional Chinese medicine based on d/d-Girard's reagent P labeling. Talanta 2023. [DOI: 10.1016/j.talanta.2022.124006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
5
|
Progress and Challenges in Quantifying Carbonyl-Metabolomic Phenomes with LC-MS/MS. Molecules 2021; 26:molecules26206147. [PMID: 34684729 PMCID: PMC8541004 DOI: 10.3390/molecules26206147] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 09/30/2021] [Accepted: 10/01/2021] [Indexed: 12/17/2022] Open
Abstract
Carbonyl-containing metabolites widely exist in biological samples and have important physiological functions. Thus, accurate and sensitive quantitative analysis of carbonyl-containing metabolites is crucial to provide insight into metabolic pathways as well as disease mechanisms. Although reversed phase liquid chromatography electrospray ionization mass spectrometry (RPLC-ESI-MS) is widely used due to the powerful separation capability of RPLC and high specificity and sensitivity of MS, but it is often challenging to directly analyze carbonyl-containing metabolites using RPLC-ESI-MS due to the poor ionization efficiency of neutral carbonyl groups in ESI. Modification of carbonyl-containing metabolites by a chemical derivatization strategy can overcome the obstacle of sensitivity; however, it is insufficient to achieve accurate quantification due to instrument drift and matrix effects. The emergence of stable isotope-coded derivatization (ICD) provides a good solution to the problems encountered above. Thus, LC-MS methods that utilize ICD have been applied in metabolomics including quantitative targeted analysis and untargeted profiling analysis. In addition, ICD makes multiplex or multichannel submetabolome analysis possible, which not only reduces instrument running time but also avoids the variation of MS response. In this review, representative derivatization reagents and typical applications in absolute quantification and submetabolome profiling are discussed to highlight the superiority of the ICD strategy for detection of carbonyl-containing metabolites.
Collapse
|
6
|
Shan L, Xu X, Zhang J, Cai P, Gao H, Lu Y, Shi J, Guo Y, Su Y. Increased hemoglobin and heme in MALDI-TOF MS analysis induce ferroptosis and promote degeneration of herniated human nucleus pulposus. Mol Med 2021; 27:103. [PMID: 34496740 PMCID: PMC8425117 DOI: 10.1186/s10020-021-00368-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Accepted: 08/31/2021] [Indexed: 12/21/2022] Open
Abstract
Background Neovasculogenesis is characteristic of herniated lumbar discs, in which extruded nucleus pulposus is prone to heme iron-induced cytotoxicity (increased oxidative stress causing ferroptosis). However, recent analyses of neovascularization are very complicated, and the mechanism of action is rarely reported. Methods Matrix-assisted laser desorption/ionization–time-of-flight mass spectrometry (MALDI-TOF MS) was performed to analyze human herniated and nonherniated nucleus pulposus. Then, the clinical relevance of the MALDI-TOF MS results and Pfirrmann classification of the degenerative nucleus pulposus were analyzed. To explore the mechanism, the heme-induced ferroptosis effect was evaluated at both the tissue and cell levels using high-resolution MALDI-TOF MS and molecular biology methods. Results The spectra revealed that hemoglobin (Hb) and heme signals were greatly increased, thus serving as predictors of vasculogenesis in herniated nucleus pulposus. The clinical relevance analysis demonstrated that the intensity of Hb and heme peaks was closely related to the Pfirrmann classification of degenerative nucleus pulposus. Mechanistically, increased heme catabolism and downregulation of glutathione peroxidase 4 (GPX4) levels were detected in herniated nucleus pulposus, reflecting iron-dependent cell death or ferroptosis. Iron levels was also increased in herniated nucleus pulposus compared with that in nonherniated nucleus pulposus. Furthermore, accuracy mass measurements confirmed that the levels of ferroptosis-related metabolites, such as glutathione, arachidonic acid (AA), sphinganine, polyunsaturated fatty acid (PUFA), and tricarboxylic acid (TCA) cycle metabolites, were significantly different between herniated and nonherniated tissues, indicating that the interior of the herniated tissues is a pro-oxidant environment. Moreover, heme-induced ferroptosis was verified in human nucleus pulposus cells (HNPCs), and the underlying mechanism might be associated with the Notch pathway. Conclusions Neovascularization in herniated nucleus pulposus may expose tissues to high levels of heme, which can induce cytotoxicity and ferroptosis within tissues and accelerate the progressive degeneration of herniated nucleus pulposus. This study is beneficial for understanding the pathological mechanism of herniated nucleus pulposus and facilitating the development of nonoperative interventions for treating lumbar disc herniation (LDH). Supplementary Information The online version contains supplementary material available at 10.1186/s10020-021-00368-2.
Collapse
Affiliation(s)
- Liang Shan
- Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai, 201203, People's Republic of China.,National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, People's Republic of China
| | - Ximing Xu
- Department of Orthopedics, Spine Surgery Section, Changzheng Hospital, Second Military Medical University, 415 Fengyang Road, Shanghai, 200003, People's Republic of China
| | - Jing Zhang
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, People's Republic of China.
| | - Peng Cai
- Shanghai Institute of Nutrition and Health, Chinese Academy of Sciences, Shanghai, 200032, People's Republic of China
| | - Han Gao
- Department of Encephalopathy, Shanghai Municipal Hospital of Traditional Chinese Medicine, Shanghai University of Traditional Chinese Medicine, Shanghai, 200071, People's Republic of China
| | - Yingjie Lu
- Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai, 201203, People's Republic of China
| | - Jiangang Shi
- Department of Orthopedics, Spine Surgery Section, Changzheng Hospital, Second Military Medical University, 415 Fengyang Road, Shanghai, 200003, People's Republic of China.
| | - Yinlong Guo
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, People's Republic of China
| | - Yue Su
- Institute of Interdisciplinary Integrative Medicine Research, Shanghai University of Traditional Chinese Medicine, 1200 Cailun Road, Shanghai, 201203, People's Republic of China.
| |
Collapse
|
7
|
Zaikin VG, Borisov RS. Options of the Main Derivatization Approaches for Analytical ESI and MALDI Mass Spectrometry. Crit Rev Anal Chem 2021; 52:1287-1342. [PMID: 33557614 DOI: 10.1080/10408347.2021.1873100] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The inclusion of preliminary chemical labeling (derivatization) in the analysis process by such powerful and widespread methods as electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is a popular and widely used methodological approach. This is due to the need to remove some fundamental limitations inherent in these powerful analytic methods. Although a number of special reviews has been published discussing the utilization of derivatization approaches, the purpose of the present critical review is to comprehensively summarize, characterize and evaluate most of the previously developed and practically applied, as well as recently proposed representative derivatization reagents for ESI-MS and MALDI-MS platforms in their mostly sensitive positive ion mode and frequently hyphenated with separation techniques. The review is focused on the use of preliminary chemical labeling to facilitate the detection, identification, structure elucidation, quantification, profiling or MS imaging of compounds within complex matrices. Two main derivatization approaches, namely the introduction of permanent charge-fixed or highly proton affinitive residues into analytes are critically evaluated. In situ charge-generation, charge-switch and charge-transfer derivatizations are considered separately. The potential of using reactive matrices in MALDI-MS and chemical labeling in MS-based omics sciences is given.
Collapse
Affiliation(s)
- Vladimir G Zaikin
- A.V. Topchiev Institute of Petrochemical Synthesis, Russian Academy of Sciences, Moscow, Russian Federation
| | - Roman S Borisov
- A.V. Topchiev Institute of Petrochemical Synthesis, Russian Academy of Sciences, Moscow, Russian Federation
| |
Collapse
|
8
|
Zhao S, Li L. Chemical Isotope Labeling LC-MS for Metabolomics. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2021; 1280:1-18. [PMID: 33791971 DOI: 10.1007/978-3-030-51652-9_1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Due to the great diversity of chemical and physical properties of metabolites as well as a wide range of concentrations of metabolites present in metabolomic samples, performing comprehensive and quantitative metabolome analysis is a major analytical challenge. Conventional approach of combining various techniques and methods with each detecting a fraction of the metabolome can lead to the increase in overall metabolomic coverage. However, this approach requires extensive investment in equipment and analytical expertise with still relatively low coverage and low sample throughput. Chemical isotope labeling (CIL) liquid chromatography mass spectrometry (LC-MS) offers an alternative means of increasing metabolomic coverage while maintaining high quantification precision and accuracy. This chapter describes the CIL LC-MS method and its key features for metabolomic analysis.
Collapse
Affiliation(s)
- Shuang Zhao
- Department of Chemistry, University of Alberta, Edmonton, AB, Canada
| | - Liang Li
- Department of Chemistry, University of Alberta, Edmonton, AB, Canada.
| |
Collapse
|
9
|
Qi W, Wang Y, Cao Y, Cao Y, Guan Q, Sun T, Zhang L, Guo Y. Simultaneous Analysis of Fatty Alcohols, Fatty Aldehydes, and Sterols in Thyroid Tissues by Electrospray Ionization-Ion Mobility-Mass Spectrometry Based on Charge Derivatization. Anal Chem 2020; 92:8644-8648. [PMID: 32574041 DOI: 10.1021/acs.analchem.0c01292] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
In this work, we developed a rapid and high-sensitivity method for simultaneous analyses of fatty alcohols, fatty aldehydes, and sterols by combining the optimized derivatization reaction with electrospray ionization-ion mobility-mass spectrometry (ESI-IM-MS). Pyridine and thionyl chloride were used as derivatization reagents as they were easily removed after the derivatization reaction and could generate permanently charged tags on different functional groups including hydroxyls and aldehydes. Through this one-step derivatization reaction, the sensitivity of detection for fatty alcohols, fatty aldehydes, and sterols was significantly increased. Moreover, the introduction of ion mobility spectrometry (IMS), offering an additional resolution power, ensured more sensitive and accurate detection of derivative products without increasing analytical time. Being connected with high-performance liquid chromatography, more than 15 kinds of compounds were analyzed within 4 min. Relative quantification using peak intensity ratios between d0-/d5-labeled ions were subsequently applied for analyzing these 15 kinds of compounds in human thyroid carcinoma and para-carcinoma tissues. The results showed significant differences in content of some analytes between these two kinds of tissues (p < 0.05). The correlations between most of the analytes in thyroid carcinoma tissues are better than the correlations in para-carcinoma tissues.
Collapse
Affiliation(s)
- Wanshu Qi
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, P. R. China
| | - Yunjun Wang
- Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center (FUSCC), Department of Oncology, Shanghai Medical College, Fudan University, 200032 Shanghai, P. R. China
| | - Yuqi Cao
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, P. R. China
| | - Yanjing Cao
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, P. R. China
| | - Qing Guan
- Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center (FUSCC), Department of Oncology, Shanghai Medical College, Fudan University, 200032 Shanghai, P. R. China
| | - Tuanqi Sun
- Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center (FUSCC), Department of Oncology, Shanghai Medical College, Fudan University, 200032 Shanghai, P. R. China
| | - Li Zhang
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, P. R. China
| | - Yinlong Guo
- State Key Laboratory of Organometallic Chemistry and National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai 200032, P. R. China
| |
Collapse
|
10
|
Using MALDI-TOF MS coupled with a high-mass detector to directly analyze intact proteins in thyroid tissues. Sci China Chem 2018. [DOI: 10.1007/s11426-017-9230-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
11
|
Harvey DJ. Analysis of carbohydrates and glycoconjugates by matrix-assisted laser desorption/ionization mass spectrometry: An update for 2011-2012. MASS SPECTROMETRY REVIEWS 2017; 36:255-422. [PMID: 26270629 DOI: 10.1002/mas.21471] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2014] [Accepted: 01/15/2015] [Indexed: 06/04/2023]
Abstract
This review is the seventh update of the original article published in 1999 on the application of MALDI mass spectrometry to the analysis of carbohydrates and glycoconjugates and brings coverage of the literature to the end of 2012. General aspects such as theory of the MALDI process, matrices, derivatization, MALDI imaging, and fragmentation are covered in the first part of the review and applications to various structural types constitute the remainder. The main groups of compound are oligo- and poly-saccharides, glycoproteins, glycolipids, glycosides, and biopharmaceuticals. Much of this material is presented in tabular form. Also discussed are medical and industrial applications of the technique, studies of enzyme reactions, and applications to chemical synthesis. © 2015 Wiley Periodicals, Inc. Mass Spec Rev 36:255-422, 2017.
Collapse
Affiliation(s)
- David J Harvey
- Department of Biochemistry, Oxford Glycobiology Institute, University of Oxford, Oxford, OX1 3QU, UK
| |
Collapse
|
12
|
Isotope-coded ESI-enhancing derivatization reagents for differential analysis, quantification and profiling of metabolites in biological samples by LC/MS: A review. J Pharm Biomed Anal 2016; 130:181-193. [DOI: 10.1016/j.jpba.2016.04.033] [Citation(s) in RCA: 56] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2016] [Revised: 04/20/2016] [Accepted: 04/20/2016] [Indexed: 12/15/2022]
|
13
|
Wang P, Zhang Q, Yao Y, Giese RW. Cationic Xylene Tag for Increasing Sensitivity in Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2015; 26:1713-1721. [PMID: 26115969 PMCID: PMC4567951 DOI: 10.1007/s13361-015-1200-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2015] [Revised: 04/29/2015] [Accepted: 05/13/2015] [Indexed: 06/04/2023]
Abstract
N-(2-(Bromomethyl)benzyl)-N,N-diethylethanaminium bromide, that we designate as CAX-B (cationic xylyl-bromide), is presented as a derivatization reagent for increasing sensitivity in mass spectrometry. Because of its aryl bromomethyl moiety, CAX-B readily labels compounds having an active hydrogen. In part, a CAX-tagged analyte (CAX-analyte) can be very sensitive especially in a tandem mass spectrometer (both ESI and MALDI). This is because of facile formation of an analyte-characteristic first product ion (as a xylyl-based cation) from favorable loss of triethylamine as a neutral from the precursor ion. This loss is enhanced both by resonance stabilization of the xylyl cation, and by anchimeric assistance from the ortho hetero atom of the attached analyte. High intensity of a first product ion opens up the opportunity for a CAX-analyte to be additionally sensitive when it is prone to a secondary neutral loss from the analyte part. For example, we have derivatized and detected 160 amol of thymidine by CAX-tagging/LC-MALDI-TOF/TOF-MS in this way, where the two neutral losses are triethylamine and deoxyribose. Other analytes detected at the amol level as CAX derivatives (as diluted standards) include estradiol and some nucleobases. The tendency for analytes with multiple active hydrogens to label just once with CAX (an advantage) is illustrated by the conversion of bisphenol A to a single product even when excess CAX-B is present. A family of analogous reagents with a variety of reactivity groups is anticipated as a consequence of replacing the bromine atom of CAX-B with various functional groups.
Collapse
Affiliation(s)
| | - Qi Zhang
- Northeastern University, Boston, MA, 02115, USA
| | | | | |
Collapse
|
14
|
Wang H, Dai B, Liu B, Lu H. Coumarins as new matrices for matrix-assisted laser-desorption/ionization Fourier transform ion cyclotron resonance mass spectrometric analysis of hydrophobic compounds. Anal Chim Acta 2015; 882:49-57. [DOI: 10.1016/j.aca.2015.04.050] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2015] [Revised: 04/15/2015] [Accepted: 04/23/2015] [Indexed: 12/17/2022]
|
15
|
Qi W, Guan Q, Sun T, Cao Y, Zhang L, Guo Y. Improving detection sensitivity of amino acids in thyroid tissues by using phthalic acid as a mobile phase additive in hydrophilic interaction chromatography-electrospray ionization-tandem mass spectrometry. Anal Chim Acta 2015; 870:75-82. [PMID: 25819789 DOI: 10.1016/j.aca.2015.02.048] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2014] [Revised: 02/13/2015] [Accepted: 02/16/2015] [Indexed: 11/25/2022]
Abstract
In this work, 0.08 mmol L(-1) of phthalic acid was introduced as a mobile phase additive to quantify free amino acids (AAs) by hydrophilic interaction liquid chromatography (HILIC) coupled with electrospray ionization tandem mass spectrometry (ESI-MS/MS). The addition of phthalic acid significantly increased the signal intensity of protonated AA ions, resulting from the decrease of the relative abundance of AA sodium adducts. Meanwhile, the chromatographic peak shapes of AAs were optimized. As a consequence, there was a noticeable increase in the sensitivity of detection for AAs. The limits of detection (LOD) and quantification (LOQ) of the AAs ranged from 0.0500 to 20.0 ng mL(-1) and from 0.100 to 50.0 ng mL(-1), respectively, which were 4-50 times lower compared to the values measured without the addition of phthalic acid. The enhanced detection and separation of AAs were obtained by merely adding phthalic acid to the mobile phase without changing other conditions. Eventually, this simple method was validated and successfully applied to the analysis of twenty-four kinds of free AAs in human thyroid carcinoma and para-carcinoma tissues, demonstrating a significant increase of most AAs in thyroid carcinoma tissues (p<0.05).
Collapse
Affiliation(s)
- Wanshu Qi
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| | - Qing Guan
- Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center (FUSCC), Shanghai 200032, China; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032, China
| | - Tuanqi Sun
- Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center (FUSCC), Shanghai 200032, China; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032, China.
| | - Yanjing Cao
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China
| | - Li Zhang
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China.
| | - Yinlong Guo
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, China.
| |
Collapse
|
16
|
Shibata Y, Arai S, Honma S. Methodological approach to the intracrine study and estimation of DHEA and DHEA-S using liquid chromatography-tandem mass spectrometry (LC-MS/MS). J Steroid Biochem Mol Biol 2015; 145:193-9. [PMID: 24794825 DOI: 10.1016/j.jsbmb.2014.04.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2014] [Revised: 03/18/2014] [Accepted: 04/02/2014] [Indexed: 12/20/2022]
Abstract
A reliable and sensitive method for analyzing steroids using liquid chromatography tandem mass spectrometry (LC-MS/MS) is required for research concerning dehydroepiandrosterone (DHEA), which plays a central role in steroid hormone biosynthesis and metabolism. Furthermore, after the first proposal of the concept of intracrine DHEA, stable isotope tracer analysis, which is useful for structural recognition as well as determination of steroids, has been required to evaluate physiological action and hormone biosynthesis/metabolism in target organs. We describe sample processing and analysis methods for simultaneous quantification of multiple hormones, including DHEA, in serum, saliva and tissue using LC-MS/MS. A derivatization technique compatible with each functional group for measuring 3β-hydroxy-5-enes, such as DHEA and 5α/5β-steroids, with high sensitivity and specificity is also described. Finally, we describe a newly developed method for intracrine research using stable isotope-labeled (13)C-steroid substrates with tracer analysis of their metabolites by LC-MS/MS.This article is part of a Special Issue entitled'Essential role of DHEA'.
Collapse
Affiliation(s)
- Yasuhiro Shibata
- Department of Urology, Gunma University Graduate School of Medicine, Maebashi, Japan.
| | - Seiji Arai
- Department of Urology, Gunma University Graduate School of Medicine, Maebashi, Japan
| | - Seijiro Honma
- School of Health Science, College of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
| |
Collapse
|
17
|
Wu M, Wang H, Dong G, Musselman BD, Liu CC, Guo Y. Combination of Solid-Phase Micro-Extraction and Direct Analysis in Real Time-Fourier Transform Ion Cyclotron Resonance Mass Spectrometry for Sensitive and Rapid Analysis of 15 Phthalate Plasticizers in Beverages. CHINESE J CHEM 2014. [DOI: 10.1002/cjoc.201400564] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
18
|
Borisov RS, Zhilyaev DI, Polovkov NY, Zaikin VG. Simple approach to derivatization of alcohols and phenols for the analysis by matrix(surface)-assisted laser desorption/ionization time-of-flight mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2014; 28:2231-2236. [PMID: 25279736 DOI: 10.1002/rcm.7008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2014] [Revised: 07/31/2014] [Accepted: 07/31/2014] [Indexed: 06/03/2023]
Abstract
RATIONALE Direct analysis of hydroxyl-containing compounds by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) methods is not always possible due to the neutral character of analytes. The suggested fixed-charge derivatization may increase the ionization efficiency for various alcohols and phenols in specific matrix- and surface-activated LDI conditions. METHODS Aliphatic and steroid alcohols, as well as chlorophenols, were converted into various ammonioacetyl derivatives, containing a covalently bonded charged group, by reaction with bromoacetyl chloride and amine-type compounds such as triethylamine, pyridine or quinoline. The derivatives are suitable for MALDI-time-of-flight (TOF)MS analysis. RESULTS Triethylammoniumacetyl, pyridyliumacetyl and quinoliniumacetyl derivatives were prepared from aliphatic alcohols, some sterols and chlorinated phenols in one stage with quantitative yields. The derivatives produced characteristic MALDI and SALDI mass spectra. CONCLUSIONS The suggested derivatization approach for the modification of alcohols is simple and does not require any expensive reagents. The derivatives include a fixed charge and produce intense signals in MALDI (preferentially non-acidic matrices) and matrix-free SALDI (nanostructured target) conditions. Corresponding mass spectra are suitable for the determination of molecular mass and profiling of alcohols.
Collapse
Affiliation(s)
- Roman S Borisov
- A.V. Topchiev Institute of Petrochemical Synthesis, Russian Academy of Sciences, Leninsky pr. 29, 119991, Moscow, Russian Federation
| | | | | | | |
Collapse
|
19
|
N-alkylpyridinium quaternization combined with liquid chromatography–electrospray ionization-tandem mass spectrometry: A highly sensitive method to quantify fatty alcohols in thyroid tissues. Anal Chim Acta 2014; 849:19-26. [DOI: 10.1016/j.aca.2014.08.027] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2014] [Revised: 08/12/2014] [Accepted: 08/17/2014] [Indexed: 11/18/2022]
|
20
|
Abdelhamid HN, Khan MS, Wu HF. Design, characterization and applications of new ionic liquid matrices for multifunctional analysis of biomolecules: A novel strategy for pathogenic bacteria biosensing. Anal Chim Acta 2014; 823:51-60. [DOI: 10.1016/j.aca.2014.03.026] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2014] [Revised: 03/16/2014] [Accepted: 03/19/2014] [Indexed: 01/01/2023]
|
21
|
Wang H, Wang H, Zhang L, Zhang J, Leng J, Cai T, Guo Y. N-alkylpyridinium quaternization for assisting electrospray ionization of sterols in oil by quadrupole-time of flight mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2013; 48:1101-1108. [PMID: 24130013 DOI: 10.1002/jms.3265] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2013] [Revised: 08/15/2013] [Accepted: 08/16/2013] [Indexed: 06/02/2023]
Abstract
RATIONALE The illegal cooking oil has become a serious social problem and raised widespread alarm recently. However, an efficient and sensitive technique for identifying the potential illegal cooking oil is still unavailable, especially when mixed with the ordinary ones; there is an urgent need to develop an efficient method for identifying the illegal cooking oil. Sterols in the cooking oil could be used as an indicator to identify the source and quality of oil by detecting the kinds of phytosterols and zoosterols. However, those sterols are difficult to be ionized by electrospray ionization, which resulted in the low sensitivity in electrospray ionization (ESI)-mass spectrometric (MS) analysis. METHODS N-alkylpyridinium isotope quaternization was extended to charge label sterols in different cooking oil and attached N-cationic pyridinium tag onto the sterols in the presence of trifluoromethanesulfonic anhydride (Tf2 O); the kinds of sterols were identified and quantified by comparing d0 /d5 pairs and product scan from ESI-quadrupole-time of flight (Q-TOF) MS analysis. RESULTS The derivatized sterols were attached with permanent charge, resulting in the significant enhancement of ionization in ESI-Q-TOF MS analysis. The detection limits of analytes were improved to 0.02-0.05 ng/mL; different kinds of phytosterol, zoosterol and oxides were identified and quantified by comparing d0 /d5 pairs from full scan and product scan. The method was applied in the detection of zoosterol for identifying the potential recycled cooking oil, even when the illegal oil has been blended into the ordinary one. More zoosterol was detected in the recycled oil compared with other cooking oil. CONCLUSIONS The use of N-alkylpyridinium isotope quaternization method provided an alternative method for identifying the potential illegal cooking oil.
Collapse
Affiliation(s)
- Hang Wang
- Shanghai Mass Spectrometry Center, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Lingling Road 345, 200032, Shanghai, China; Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Zuchongzhi Road 555, 201203, China
| | | | | | | | | | | | | |
Collapse
|
22
|
Abdelhamid HN, Gopal J, Wu HF. Synthesis and application of ionic liquid matrices (ILMs) for effective pathogenic bacteria analysis in matrix assisted laser desorption/ionization (MALDI-MS). Anal Chim Acta 2013; 767:104-11. [DOI: 10.1016/j.aca.2012.12.054] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2012] [Revised: 12/25/2012] [Accepted: 12/26/2012] [Indexed: 10/27/2022]
|
23
|
Wang H, Wang H, Zhang L, Zhang J, Zhuo X, Huang Y, Guo Y. Comparison of Hair Fatty Alcohols byN-Alkylpyridinium Isotope Quaternization and Matrix-assisted Laser Desorption/ionization Mass Spectrometry for Drug Abuse Monitoring. CHINESE J CHEM 2012. [DOI: 10.1002/cjoc.201200547] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
24
|
Chemical and Biochemical Applications of MALDI TOF-MS Based on Analyzing the Small Organic Compounds. Top Curr Chem (Cham) 2012; 331:165-92. [DOI: 10.1007/128_2012_364] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|