1
|
Kim A, Kelly PF, Turner MA, Reynolds JC. A direct analysis method using sheath flow probe electrospray ionisation-mass spectrometry (sfPESI-MS) to detect drug residues from fingerprint forensic gel lifts. Drug Test Anal 2024. [PMID: 38589994 DOI: 10.1002/dta.3688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 03/04/2024] [Accepted: 03/14/2024] [Indexed: 04/10/2024]
Abstract
Latent fingerprints at crime scenes are frequently recovered using forensic gel-lifters, which can help to preserve the crime scene and to enhance visualisation of traces such as blood or paint. In addition to providing fingerprint ridge detail, additional chemical information can also be recovered from gel lifts that may prove pertinent to an investigation. However, while DNA and metal ions have been shown to be able to be detected in gel-lifted fingerprints, the determination of other types of chemical information such as the presence of drugs in gel-lifted prints has not been previously shown. This study demonstrates the application of an ambient ionisation method, sheath flow probe electrospray ionisation-mass spectrometry (sfPESI-MS), to the direct analysis of gel-lifted fingerprints. A model drug compound (zolpidem) is successfully detected from gel-lifted prints from three different surface types: glass, metal, and paper. The surface activity-based separation associated with probe electrospray approaches is shown to resolve zolpidem ions from background phthalate species, significantly enhancing the response obtained from the gel-lifter. A depletion series experiment shows that the drug residue can be detected with up to 100% efficiency after eight consecutive contacts; however, detection efficiency drops to 20% after 30 contacts. The developed approach has potential application to analysis of historical gel-lifters to obtain additional chemical information.
Collapse
Affiliation(s)
- Ayoung Kim
- Centre for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, UK
| | - Paul F Kelly
- Centre for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, UK
| | - Matthew A Turner
- Centre for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, UK
| | - James C Reynolds
- Centre for Analytical Science, Department of Chemistry, Loughborough University, Loughborough, UK
| |
Collapse
|
2
|
Bouza M, Foest D, Brandt S, García-Reyes JF, Franzke J. Enhanced Compound Analysis Using Reactive Paper Spray Mass Spectrometry: Leveraging Schiff Base Reaction for Amino Acid Detection. Anal Chem 2024; 96:5289-5297. [PMID: 38507224 PMCID: PMC10993198 DOI: 10.1021/acs.analchem.4c00215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 02/29/2024] [Accepted: 03/04/2024] [Indexed: 03/22/2024]
Abstract
Paper spray mass spectrometry (PS-MS) has evolved into a promising tool for monitoring reactions in thin films and microdroplets, known as reactive PS, alongside its established role in ambient and direct ionization. This study addresses the need for rapid, cost-effective methods to improve analyte identification in biofluids by leveraging reactive PS-MS in clinical chemistry environments. The technique has proven effective in derivatizing target analytes, altering hydrophobicity to enhance elution and ionization efficiency, and refining detection through thin-film reactions on paper, significantly expediting reaction rates by using amino acids (AAs) as model analytes. These molecules are prone to interacting with substrates like paper, impeding elution and detection. Additionally, highly abundant species in biofluids, such as lipids, often suppress AA ionization. This study employs the Schiff base (SB) reaction utilizing aromatic aldehydes for AA derivatization to optimize reaction conditions time, temperature, and catalyst presence and dramatically increasing the conversion ratio (CR) of formed SB. For instance, using leucine as a model AA, the CR surged from 57% at room temperature to 89% at 70 °C, with added pyridine during and after 7.5 min, displaying a 43% CR compared to the bulk reaction. Evaluation of various aromatic aldehydes as derivatization agents highlighted the importance of specific oxygen substituents for achieving higher conversion rates. Furthermore, diverse derivatization agents unveiled unique fragmentation pathways, aiding in-depth annotation of the target analyte. Successfully applied to quantify AAs in human and rat plasma, this reactive PS-MS approach showcases promising potential in efficiently detecting conventionally challenging compounds in PS-MS analysis.
Collapse
Affiliation(s)
- Marcos Bouza
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, Jaén 23071, Spain
| | - Daniel Foest
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, Dortmund 44139, Germany
| | - Sebastian Brandt
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, Dortmund 44139, Germany
| | - Juan F. García-Reyes
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, Jaén 23071, Spain
| | - Joachim Franzke
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, Dortmund 44139, Germany
| |
Collapse
|
3
|
de Paula CCA, Binatti I, Coelho Pimenta JV, Augusti R. Accelerated synthesis of phthalimide derivatives: Intrinsic reactivity of diamines towards phthalic anhydride evaluated by paper spray ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9407. [PMID: 36169595 DOI: 10.1002/rcm.9407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 09/01/2022] [Accepted: 09/26/2022] [Indexed: 06/16/2023]
Abstract
RATIONALE Paper spray (PS) is a simple and innovative ambient ionization technique for mass spectrometry (MS) analysis. Under PS-MS conditions, chemical reactions, which usually occur slowly on a bulk scale, are accelerated. Moreover, the formation of products and transient species can be easily monitored. In this manuscript, reactions between phthalic anhydride and diamines were conducted and monitored using a PS-MS platform. The reaction products (phthalimides) have many pharmaceutical applications, but their traditional syntheses can take hours under reflux, requiring laborious purification steps. METHODS In situ reactions were performed by dropping methanolic solutions of phthalic anhydride and diamines on a triangular paper. The analyses were achieved by positioning the triangle tip in front of the mass spectrometer entrance, whereas a metal clip was attached to the triangle base. After adding methanol to the paper, a high voltage was applied across the metal clip, and the mass spectra were acquired. RESULTS The intrinsic reactivity of alkyl and aromatic diamines was evaluated. The carbon chain remarkably influenced the reactivity of aliphatic diamines. For aryl diamines, the ortho isomer was the most reactive. Moreover, for aryl amines with electron-withdrawing substituents, no reaction was noticed. CONCLUSIONS Taking advantage of the unique characteristics of PS-MS, it was possible to investigate the intrinsic reactivity of model alkyl (ethylene versus propylene) and aryl (o-phenylene versus m-phenylene and p-phenylene) diamines towards phthalic anhydride. Some crucial parameters that affect the intrinsic reactivity of organic molecules, such as isomerism, intramolecular interaction, and conformation, were easily explored.
Collapse
Affiliation(s)
| | | | | | - Rodinei Augusti
- Departamento de Química, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| |
Collapse
|
4
|
Lin Q, Xue L, Sun J, Wang Y, Cheng H. Suzuki C-C Coupling in Paper Spray Ionization: Microsynthesis of Biaryls and High-Sensitivity MS Detection of Aryl Bromides. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:1921-1935. [PMID: 36074999 DOI: 10.1021/jasms.2c00192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Suzuki-Miyaura cross-coupling is one of the most powerful strategies for constructing biaryl compounds. However, classic Suzuki-Miyaura coupling suffers from hour-scale reaction time and competitive protodeboronation. To address these problems, a mild nonaqueous potassium trimethylsilanolate (TMSOK)-assisted Suzuki-Miyaura coupling strategy was designed for the microsynthesis of biaryls in paper spray ionization (PSI). Due to the acceleration power facilitated by microdroplet chemistry in reactive PSI, the microsynthesis of biaryls by reactive PSI was accomplished within minutes with comparable yields to the bulk, showing good substrate applicability from 32 Suzuki-Miyaura reactions of aryl bromides and aryl boronic acid/borates bearing different substituents. Based on the above TMSOK-assisted Suzuki-Miyaura coupling strategy, we further developed a high-sensitivity and selective PSI mass spectrometry (MS) method for quantitative analysis of aryl bromides, a class of environmentally persistent organic pollutants that cannot be directly detected by ambient mass spectrometry due to their low ionization efficiency. In situ derivatization of aryl bromides was achieved with aryl borates bearing quaternary ammonium groups in PSI. The proposed PSI-MS method shows good linearity over the 0.01-10 μmol L-1 range with low detection limits of 1.8-4.8 nmol L-1 as well as good applicability to the rapid determination of six aryl bromides in three environmental water samples. The proposed PSI-MS method also shows good applicability to brominated flame retardants (polybrominated diphenyls/diphenyl esters). Overall, this study provides a simple, rapid, low-cost, high-sensitivity, and high-selectivity strategy for trace aryl bromides and other brominated pollutants in real samples with minimal/no sample pretreatment.
Collapse
Affiliation(s)
- Qiuyu Lin
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
- Sinopec Zhenhai Refining & Chemical Company, 226 Lianhua Road, Zhenhai District, Ningbo 315207, China
| | - Luyun Xue
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
| | - Jiannan Sun
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
| | - Yuanchao Wang
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
| | - Heyong Cheng
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
| |
Collapse
|
5
|
Lin Q, Sun J, Wang Y, Ye M, Cheng H. Rapid determination of aldehydes in food by high-throughput reactive paper spray ionization mass spectrometry. J Food Compost Anal 2022. [DOI: 10.1016/j.jfca.2022.104814] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
6
|
Borden SA, Saatchi A, Palaty J, Gill CG. A direct mass spectrometry method for cannabinoid quantitation in urine and oral fluid utilizing reactive paper spray ionization. Analyst 2022; 147:3109-3117. [DOI: 10.1039/d2an00743f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Reactive paper spray mass spectrometry mitigates many of the challenges associated with direct cannabinoid measurements, allowing for rapid, reliable and quantitative measurements in oral fluid and in urine at clinically relevant levels.
Collapse
Affiliation(s)
- Scott A. Borden
- Applied Environmental Research Laboratories, Department of Chemistry, Vancouver Island University, Nanaimo, BC, Canada
- Department of Chemistry, University of Victoria, Victoria, BC, Canada
| | - Armin Saatchi
- Applied Environmental Research Laboratories, Department of Chemistry, Vancouver Island University, Nanaimo, BC, Canada
- Department of Chemistry, University of Victoria, Victoria, BC, Canada
| | - Jan Palaty
- LifeLabs Medical Laboratories, Burnaby, BC, Canada
| | - Chris G. Gill
- Applied Environmental Research Laboratories, Department of Chemistry, Vancouver Island University, Nanaimo, BC, Canada
- Department of Chemistry, University of Victoria, Victoria, BC, Canada
- Department of Chemistry, Simon Fraser University, Burnaby, BC, Canada
- Department of Environmental and Occupational Health Sciences, University of Washington, Seattle, WA, USA
| |
Collapse
|
7
|
Li Z, Li Y, Zhan L, Meng L, Huang X, Wang T, Li Y, Nie Z. Point-of-Care Test Paper for Exhaled Breath Aldehyde Analysis via Mass Spectrometry. Anal Chem 2021; 93:9158-9165. [PMID: 34162204 DOI: 10.1021/acs.analchem.1c01011] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Volatile organic compounds (VOCs) from exhaled breath (EB) are considered to be promising biomarkers for lung diseases. A convenient and sensitive point-of-care (POC) testing method for EB VOCs is essential. Here, we developed a POC test paper for the analysis of EB aldehydes, which are potential biomarkers for lung cancer. A probe molecule, 4-aminothiophenol (4-ATP), was anchored on a paper substrate to specifically capture gas-phase aldehydes through the Schiff base reaction. Meanwhile, thin-film reaction acceleration was utilized to increase capture efficiency. By directly coupling the test paper to a mass spectrometer through paper spray, high sensitivity (0.1 ppt) and a wide quantification linear range (from 10 ppt to 1 ppm) were obtained. Analysis of EB from lung cancer patients with the test paper showed a significant increase in several reported aldehyde markers compared to EB from healthy volunteers, indicating the potential of this method for sensitive, low-cost, and convenient lung cancer screening and diagnosis.
Collapse
Affiliation(s)
- Zhengzhou Li
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yuze Li
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lingpeng Zhan
- Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China
| | - Lingwei Meng
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xi Huang
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Tie Wang
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yafeng Li
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China
| | - Zongxiu Nie
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190, China.,University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
8
|
Aquino A, Mayrink Alves Pereira G, Dossi N, Piccin E, Augusti R. Reagent-Pencil and Paper Spray Mass Spectrometry: A Convenient Combination for Selective Analyses in Complex Matrixes. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:281-288. [PMID: 33176096 DOI: 10.1021/jasms.0c00321] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The recent developments on fieldable miniature mass spectrometers require efforts to produce easy-to-use and portable alternative tools to assist in point-of-care analysis. In this paper, the reagent-pencil (RP) technology, which has been used for solvent-free deposition of reagents in paper-based microfluidics, was combined with paper spray ionization mass spectrometry (PS-MS). In this approach, named RP-PS-MS, the PS triangular piece of paper was written with the reagent pencil, consisting of mixtures of graphite and bentonite (used as a support) and a reactive compound, and allowed to react with a given analyte from a sample matrix selectively. We conducted typical applications as proof-of-principles to verify the methodology's general usefulness in detecting small organic molecules in distinct samples. Hence, various aldehydes (2-furaldehyde, valeraldehyde, and benzaldehyde) in spiked cachaça samples (an alcoholic drink produced from fermentation/distillation of sugarcane juice) were promptly detected using a reagent pencil doped with 4-aminophenol (the reactive compound). Similarly, we recognized typical ginsenosides and triacylglycerols (TAGs) in ginseng aqueous infusions and soybean oil samples, respectively, using lithium chloride as the reactive compound. The results indicate that the reagent-pencil methodology is compatible with PS-MS and provides an easy and fast way to detect target analytes in complex samples. The advantage over the usual solution-based deposition of reagents lies in the lack of preparation or carrying different specific solutions for special applications, which can simplify operation, especially in point-of-care analysis with fieldable mass spectrometers.
Collapse
Affiliation(s)
- Adriano Aquino
- Universidade Federal de Minas Gerais, Instituto de Ciências Exatas, Departamento de Química, Belo Horizonte, 31270-400, Minas Gerais, Brazil
| | - Giovana Mayrink Alves Pereira
- Universidade Federal de Minas Gerais, Instituto de Ciências Exatas, Departamento de Química, Belo Horizonte, 31270-400, Minas Gerais, Brazil
| | - Nicolò Dossi
- Department of Agrifood, Environmental and Animal Science, University of Udine, Udine, I-33100, Italy
| | - Evandro Piccin
- Universidade Federal de Minas Gerais, Instituto de Ciências Exatas, Departamento de Química, Belo Horizonte, 31270-400, Minas Gerais, Brazil
| | - Rodinei Augusti
- Universidade Federal de Minas Gerais, Instituto de Ciências Exatas, Departamento de Química, Belo Horizonte, 31270-400, Minas Gerais, Brazil
| |
Collapse
|
9
|
Abstract
Direct ambient ionization techniques have been developed with the aim to reduce the complexity of mass spectrometry analysis by minimizing sample preparation and chromatographic separation. In this context, paper spray-MS (PS-MS) is an innovative approach that provides faster and cheaper analysis of biofluids by the addition of the sample directly to a paper. In forensic toxicology, the analytical workflow for the detection and quantification of drugs of abuse is onerous, including sample treatment, extraction and clean up, especially regarding complex biological matrices. PS-MS allows the detection of analytes of toxicological interest in blood, plasma and urine using low sample volume. This review aims to discuss the potential use, advances and challenges of PS-MS in forensic toxicology.
Collapse
|
10
|
Frey BS, Damon DE, Badu-Tawiah AK. Emerging trends in paper spray mass spectrometry: Microsampling, storage, direct analysis, and applications. MASS SPECTROMETRY REVIEWS 2020; 39:336-370. [PMID: 31491055 PMCID: PMC7875099 DOI: 10.1002/mas.21601] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Accepted: 07/22/2019] [Indexed: 05/20/2023]
Abstract
Recent advancements in the sensitivity of chemical instrumentation have led to increased interest in the use of microsamples for translational and biomedical research. Paper substrates are by far the most widely used media for biofluid collection, and mass spectrometry is the preferred method of analysis of the resultant dried blood spot (DBS) samples. Although there have been a variety of review papers published on DBS, there has been no attempt to unify the century old DBS methodology with modern applications utilizing modified paper and paper-based microfluidics for sampling, storage, processing, and analysis. This critical review will discuss how mass spectrometry has expanded the utility of paper substrates from sample collection and storage, to direct complex mixture analysis to on-surface reaction monitoring.
Collapse
Affiliation(s)
- Benjamin S Frey
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio, 43210
| | - Deidre E Damon
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio, 43210
| | - Abraham K Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio, 43210
| |
Collapse
|
11
|
Díaz-Liñán MC, García-Valverde MT, Lucena R, Cárdenas S, López-Lorente AI. Paper-based sorptive phases for microextraction and sensing. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:3074-3091. [PMID: 32930167 DOI: 10.1039/d0ay00702a] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The simplification of the analytical procedures, including cost-effective materials and detectors, is a current research trend. In this context, paper has been identified as a useful material thanks to its low price and high availability in different compositions (office, filter, chromatographic). Its porosity, flexibility, and planar geometry permit the design of flow-through devices compatible with most instrumental techniques. This article provides a general overview of the potential of paper, as substrate, on the simplification of analytical chemistry methodologies. The design of paper-based sorptive phases is considered in-depth, and the different functionalization strategies are described. Considering our experience in sample preparation, special attention has been paid to the use of these phases under the classical microextraction-analysis workflow, which usually includes a chromatographic separation of the analytes before their determination. However, the interest of these materials extends beyond this field as they can be easily implemented into spectroscopic and electrochemical sensors. Finally, the direct analysis of paper substrates in mass spectrometry, in the so-called paper-spray technique is also discussed. This review is more focused on presenting ideas rather than the description of specific applications to draw a general picture of the potential of these materials.
Collapse
Affiliation(s)
- M C Díaz-Liñán
- Departamento de Química Analítica, Instituto, Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071 Córdoba, Spain.
| | - M T García-Valverde
- Departamento de Química Analítica, Instituto, Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071 Córdoba, Spain.
| | - R Lucena
- Departamento de Química Analítica, Instituto, Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071 Córdoba, Spain.
| | - S Cárdenas
- Departamento de Química Analítica, Instituto, Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071 Córdoba, Spain.
| | - A I López-Lorente
- Departamento de Química Analítica, Instituto, Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071 Córdoba, Spain.
| |
Collapse
|
12
|
Kuo TH, Dutkiewicz EP, Pei J, Hsu CC. Ambient Ionization Mass Spectrometry Today and Tomorrow: Embracing Challenges and Opportunities. Anal Chem 2019; 92:2353-2363. [DOI: 10.1021/acs.analchem.9b05454] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Ting-Hao Kuo
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| | - Ewelina P. Dutkiewicz
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan
- Agricultural Biotechnology Research Center, Academia Sinica, Taipei 11529, Taiwan
| | - Jiying Pei
- School of Marine Sciences, Guangxi University, Nanning, Guangxi 530004, PR China
| | - Cheng-Chih Hsu
- Department of Chemistry, National Taiwan University, Taipei 10617, Taiwan
| |
Collapse
|
13
|
Choi S, Cha S. Investigation of Reactions Between Isothiazolinones and Cysteamine by Reactive Paper Spray Ionization Mass Spectrometry (Reactive PSI MS). B KOREAN CHEM SOC 2019. [DOI: 10.1002/bkcs.11916] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Soobin Choi
- Department of ChemistryHankuk University of Foreign Studies Yongin 17035 South Korea
| | - Sangwon Cha
- Department of ChemistryHankuk University of Foreign Studies Yongin 17035 South Korea
| |
Collapse
|
14
|
McBride EM, Mach PM, Dhummakupt ES, Dowling S, Carmany DO, Demond PS, Rizzo G, Manicke NE, Glaros T. Paper spray ionization: Applications and perspectives. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.06.028] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
15
|
Zhu H, Huang G. High-throughput paper spray mass spectrometry via induced voltage. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33:392-398. [PMID: 30394606 DOI: 10.1002/rcm.8336] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2018] [Revised: 10/23/2018] [Accepted: 10/26/2018] [Indexed: 06/08/2023]
Abstract
RATIONALE Paper spray (PS) has been developed as a method of choice for point-of-care analysis in many real cases, where its applications can be further expanded with delicate high-throughput design. To achieve this goal, we developed a new PS regime, with the assembly of an induced high voltage into the ion source. Compared with regular DC high voltage, the newly developed setup is capable of high-throughput, simple configuration and rapid switching between individual papers without complicated electric/mechanic design. METHODS A device of high-throughput induced PS (IPS) was designed by using a two-dimensional (2D) rotating platform equipped with a circular glass plate. The paper substrate was placed on the circular glass plate and separated from the electrode. The method avoids physical contact between the electrode and the sample. Charged droplets were generated at the paper tip once an induced high voltage was applied to a wet paper. RESULTS A relatively rapid analytical speed of 2.6 s per sample was achieved via IPS-MS. Rapid quantification of amitriptyline (AMT) in complicated matrices was obtained within 1 min using an isotope internal standard method. Limits of detection for AMt in urine, FBS and blood were calculated to be 1.04, 0.84 and 1.33 ng/mL, respectively. In addition, high-throughput IPS-MS can be used for chemical reaction monitoring. CONCLUSIONS We have demonstrated the versatility of high-throughput IPS-MS in ambient ionization, which successfully simplified the experimental installation and facilitated the experimental operation. Therefore, we believe that high-throughput IPS-MS analysis will be widely used for discovering drugs and screening reactions, and the present design has the potential for applications in paper chip-MS analysis.
Collapse
Affiliation(s)
- Haijing Zhu
- Department of Chemistry, School of Chemistry and Materials Science, University of Science and Technology of China (USTC), Hefei, 230026, China
| | - Guangming Huang
- Department of Chemistry, School of Chemistry and Materials Science, University of Science and Technology of China (USTC), Hefei, 230026, China
| |
Collapse
|
16
|
Chen L, Fu YJ, Fang WL, Guo XF, Wang H. Screening of a highly effective fluorescent derivatization reagent for carbonyl compounds and its application in HPLC with fluorescence detection. Talanta 2018; 186:221-228. [DOI: 10.1016/j.talanta.2018.04.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 03/23/2018] [Accepted: 04/07/2018] [Indexed: 01/28/2023]
|
17
|
Lara-Ortega FJ, Beneito-Cambra M, Robles-Molina J, García-Reyes JF, Gilbert-López B, Molina-Díaz A. Direct olive oil analysis by mass spectrometry: A comparison of different ambient ionization methods. Talanta 2018; 180:168-175. [DOI: 10.1016/j.talanta.2017.12.027] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2017] [Revised: 12/07/2017] [Accepted: 12/11/2017] [Indexed: 10/18/2022]
|
18
|
Bain RM, Ayrton ST, Cooks RG. Fischer Indole Synthesis in the Gas Phase, the Solution Phase, and at the Electrospray Droplet Interface. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1359-1364. [PMID: 28194736 DOI: 10.1007/s13361-017-1597-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2016] [Revised: 01/06/2017] [Accepted: 01/07/2017] [Indexed: 06/06/2023]
Abstract
Previous reports have shown that reactions occurring in the microdroplets formed during electrospray ionization can, under the right conditions, exhibit significantly greater rates than the corresponding bulk solution-phase reactions. The observed acceleration under electrospray ionization could result from a solution-phase, a gas-phase, or an interfacial reaction. This study shows that a gas-phase ion/molecule (or ion/ion) reaction is not responsible for the observed rate enhancement in the particular case of the Fischer indole synthesis. The results show that the accelerated reaction proceeds in the microdroplets, and evidence is provided that an interfacial process is involved. Graphical Abstract <!-- [INSERT GRAPHICAL ABSTRACT TEXT HERE] -->.
Collapse
Affiliation(s)
- Ryan M Bain
- 560 Oval Drive Department of Chemistry and the Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, 47907, USA
| | - Stephen T Ayrton
- 560 Oval Drive Department of Chemistry and the Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, 47907, USA
| | - R Graham Cooks
- 560 Oval Drive Department of Chemistry and the Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, 47907, USA.
| |
Collapse
|
19
|
Xie X, Wang Z, Li Y, Zhan L, Nie Z. Investigation and Applications of In-Source Oxidation in Liquid Sampling-Atmospheric Pressure Afterglow Microplasma Ionization (LS-APAG) Source. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1036-1047. [PMID: 27995501 DOI: 10.1007/s13361-016-1550-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2016] [Revised: 10/28/2016] [Accepted: 10/29/2016] [Indexed: 06/06/2023]
Abstract
A liquid sampling-atmospheric pressure afterglow microplasma ionization (LS-APAG) source is presented for the first time, which is embedded with both electrospray ionization (ESI) and atmospheric pressure afterglow microplasma ionization (APAG) techniques. This ion source is capable of analyzing compounds with diverse molecule weights and polarities. An unseparated mixture sample was detected as a proof-of-concept, giving complementary information (both polarities and non-polarities) with the two ionization modes. It should also be noted that molecular mass can be quickly identified by ESI with clean and simple spectra, while the structure can be directly studied using APAG with in-source oxidation. The ionization/oxidation mechanism and applications of the LS-APAG source have been further explored in the analysis of nonpolar alkanes and unsaturated fatty acids/esters. A unique [M + O - 3H]+ was observed in the case of individual alkanes (C5-C19) and complex hydrocarbons mixture under optimized conditions. Moreover, branched alkanes generated significant in-source fragments, which could be further applied to the discrimination of isomeric alkanes. The technique also facilitates facile determination of double bond positions in unsaturated fatty acids/esters due to diagnostic fragments (the acid/ester-containing aldehyde and acid oxidation products) generated by on-line ozonolysis in APAG mode. Finally, some examples of in situ APAG analysis by gas sampling and surface sampling were given as well. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Xiaobo Xie
- Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Zhenpeng Wang
- National Center for Mass Spectrometry in Beijing, Beijing, 100190, China
| | - Yafeng Li
- Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
| | - Lingpeng Zhan
- Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Zongxiu Nie
- Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China.
- University of Chinese Academy of Sciences, Beijing, 100049, China.
- National Center for Mass Spectrometry in Beijing, Beijing, 100190, China.
| |
Collapse
|
20
|
Gabriel EFM, Garcia PT, Evans E, Cardoso TMG, Garcia CD, Coltro WKT. Enhanced Performance of Colorimetric Biosensing on Paper Microfluidic Platforms Through Chemical Modification and Incorporation of Nanoparticles. Methods Mol Biol 2017; 1571:327-341. [PMID: 28281265 DOI: 10.1007/978-1-4939-6848-0_20] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
This chapter describes two different methodologies used to improve the analytical performance of colorimetric paper-based biosensors. Microfluidic paper-based analytical devices (μPADs) have been produced by a stamping process and CO2 laser ablation and modified, respectively, through an oxidation step and incorporation of silica nanoparticles on the paper structure. Both methods are employed in order to overcome the largest problem associated with colorimetric detection, the heterogeneity of the color distribution in the detection zones. The modification steps are necessary to improve the interaction between the paper surface and the selected enzymes. The enhanced performance has ensured reliability for quantitative analysis of clinically relevant compounds.
Collapse
Affiliation(s)
| | - Paulo T Garcia
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Elizabeth Evans
- Department of Chemistry, Clemson University, Clemson, SC 29634, TX, 78249, USA
| | - Thiago M G Cardoso
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil
| | - Carlos D Garcia
- Department of Chemistry, Clemson University, Clemson, SC 29634, TX, 78249, USA
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, Campus Samambaia, 74690-900, Goiânia, GO, Brazil.
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica (INCTBio), Campinas, SP, Brazil.
| |
Collapse
|
21
|
Affiliation(s)
- Patricia M Peacock
- First State IR, LLC , 118 Susan Drive, Hockessin, Delaware 19707, United States
| | - Wen-Jing Zhang
- Department of Chemistry, Wayne State University , 5101 Cass Avenue, Detroit, Michigan 48202, United States
| | - Sarah Trimpin
- Department of Chemistry, Wayne State University , 5101 Cass Avenue, Detroit, Michigan 48202, United States
| |
Collapse
|
22
|
Kennedy J, Shanks KG, Van Natta K, Prieto Conaway MC, Wiseman JM, Laughlin B, Kozak M. Rapid screening and identification of novel psychoactive substances using PaperSpray interfaced to high resolution mass spectrometry. CLINICAL MASS SPECTROMETRY (DEL MAR, CALIF.) 2016; 1:3-10. [PMID: 39193420 PMCID: PMC11322720 DOI: 10.1016/j.clinms.2016.08.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2016] [Revised: 08/23/2016] [Accepted: 08/23/2016] [Indexed: 12/26/2022]
Abstract
The simple and rapid detection and identification of designer drugs is of substantial importance to forensic scientists and law enforcement. Although synthetic cathinones, cannabinoids, and other common novel psychoactive substances (NPS) are produced for purposes that do not include human consumption, they are regularly abused. The analysis of these compounds is often achieved using mass spectrometry, but can be complicated by the lack of spectral libraries and the scarcity of simple and reliable sample introduction techniques. PaperSpray® ionization is a new, automated technique for rapid analysis of samples, without chromatography or prior purification. Matrix, such as powder or plant material, is dissolved or extracted with common solvents and deposited directly on disposable PaperSpray® cartridges for high-throughput, automated analysis. The combination of PaperSpray® sample introduction and High Resolution Accurate Mass Spectrometry (HRAM) provides a powerful and simple tool for identification of new substances, without requiring reference standards.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Marta Kozak
- Thermo Fisher Scientific, San Jose, CA, United States
| |
Collapse
|
23
|
Direct Analysis and Quantification of Metaldehyde in Water using Reactive Paper Spray Mass Spectrometry. Sci Rep 2016; 6:35643. [PMID: 27767044 PMCID: PMC5073298 DOI: 10.1038/srep35643] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2016] [Accepted: 09/30/2016] [Indexed: 12/22/2022] Open
Abstract
Metaldehyde is extensively used worldwide as a contact and systemic molluscicide for controlling slugs and snails in a wide range of agricultural and horticultural crops. Contamination of surface waters due to run-off, coupled with its moderate solubility in water, has led to increased concentration of the pesticide in the environment. In this study, for the first time, rapid analysis (<~1 minute) of metaldehyde residues in water is demonstrated using paper spray mass spectrometry (PS-MS). The observed precursor molecular ions of metaldehyde were confirmed from tandem mass spectrometry (MS/MS) experiments by studying the fragmentation patterns produced via collision-induced dissociation. The signal intensity ratios of the most abundant MS/MS transitions for metaldehyde (177 → 149 for protonated ion) and atrazine (221 → 179) were found to be linear in the range 0.01 to 5 ng/mL. Metaldehyde residues were detectable in environmental water samples at low concentration (LOD < 0.1 ng/mL using reactive PS-MS), with a relative standard deviation <10% and an R2 value >0.99, without any pre-concentration/separation steps. This result is of particular importance for environmental monitoring and water quality analysis providing a potential means of rapid screening to ensure safe drinking water.
Collapse
|
24
|
Charged tag founded in N-(1-chloroalkyl)pyridinium quaternization for quantification of fatty aldehydes. Anal Chim Acta 2016; 937:80-6. [DOI: 10.1016/j.aca.2016.05.032] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2016] [Revised: 05/18/2016] [Accepted: 05/22/2016] [Indexed: 01/31/2023]
|
25
|
Crawford EA, Esen C, Volmer DA. Real Time Monitoring of Containerless Microreactions in Acoustically Levitated Droplets via Ambient Ionization Mass Spectrometry. Anal Chem 2016; 88:8396-403. [DOI: 10.1021/acs.analchem.6b01519] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Elizabeth A. Crawford
- Institute
of Bioanalytical Chemistry, Saarland University, 66123 Saarbrücken, Germany
| | - Cemal Esen
- Department
of Mechanical Engineering, Ruhr-University Bochum, 44801 Bochum, Germany
| | - Dietrich A. Volmer
- Institute
of Bioanalytical Chemistry, Saarland University, 66123 Saarbrücken, Germany
| |
Collapse
|
26
|
Abstract
Paper spray MS is part of a cohort of ambient ionization or direct analysis methods that seek to analyze complex samples without prior sample preparation. Extraction and electrospray ionization occur directly from the paper substrate upon which a dried matrix spot is stored. Paper spray MS is capable of detecting drugs directly from dried blood, plasma and urine spots at the low ng/ml to pg/ml levels without sample preparation. No front end separation is performed, so MS/MS or high-resolution MS is required. Here, we discuss paper spray methodology, give a comprehensive literature review of the use of paper spray MS for bioanalysis, discuss technological advancements and variations on this technique and discuss some of its limitations.
Collapse
|
27
|
Affiliation(s)
- Dalton T. Snyder
- Department of Chemistry and Center for Analytical Instrumentation
Development, Purdue University, W. Lafayette, IN 47907
| | - Christopher J. Pulliam
- Department of Chemistry and Center for Analytical Instrumentation
Development, Purdue University, W. Lafayette, IN 47907
| | - Zheng Ouyang
- Weldon School of Biomedical Engineering, Purdue University, W.
Lafayette, IN 47907
| | - R. Graham Cooks
- Department of Chemistry and Center for Analytical Instrumentation
Development, Purdue University, W. Lafayette, IN 47907
| |
Collapse
|
28
|
Liu YM, Perry RH. Paper-Based Electrochemical Cell Coupled to Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2015; 26:1702-1712. [PMID: 26311335 DOI: 10.1007/s13361-015-1224-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2015] [Revised: 06/15/2015] [Accepted: 06/17/2015] [Indexed: 06/04/2023]
Abstract
On-line coupling of electrochemistry (EC) to mass spectrometry (MS) is a powerful approach for identifying intermediates and products of EC reactions in situ. In addition, EC transformations have been used to increase ionization efficiency and derivatize analytes prior to MS, improving sensitivity and chemical specificity. Recently, there has been significant interest in developing paper-based electroanalytical devices as they offer convenience, low cost, versatility, and simplicity. This report describes the development of tubular and planar paper-based electrochemical cells (P-EC) coupled to sonic spray ionization (SSI) mass spectrometry (P-EC/SSI-MS). The EC cells are composed of paper sandwiched between two mesh stainless steel electrodes. Analytes and reagents can be added directly to the paper substrate along with electrolyte, or delivered via the SSI microdroplet spray. The EC cells are decoupled from the SSI source, allowing independent control of electrical and chemical parameters. We utilized P-EC/SSI-MS to characterize various EC reactions such as oxidations of cysteine, dopamine, polycyclic aromatic hydrocarbons, and diphenyl sulfide. Our results show that P-EC/SSI-MS has the ability to increase ionization efficiency, to perform online EC transformations, and to capture intermediates of EC reactions with a response time on the order of hundreds of milliseconds. The short response time allowed detection of a deprotonated diphenyl sulfide intermediate, which experimentally confirms a previously proposed mechanism for EC oxidation of diphenyl sulfide to pseudodimer sulfonium ion. This report introduces paper-based EC/MS via development of two device configurations (tubular and planar electrodes), as well as discusses the capabilities, performance, and limitations of the technique.
Collapse
Affiliation(s)
- Yao-Min Liu
- Department of Chemistry, University of Illinois, Urbana, IL, 61801, USA
| | - Richard H Perry
- Department of Chemistry, University of Illinois, Urbana, IL, 61801, USA.
| |
Collapse
|
29
|
|