1
|
Gao H, Gao S, Lv M, Liu Y, Yao J, Liu H, Wang F, Chen M, Wan L. Determination of hydroxypolycyclic aromatic hydrocarbons in urine by electromembrane extraction coupled with liquid chromatography. J Chromatogr A 2024; 1736:465375. [PMID: 39284253 DOI: 10.1016/j.chroma.2024.465375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2024] [Revised: 09/10/2024] [Accepted: 09/11/2024] [Indexed: 10/23/2024]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) have been classified as the earliest discovered class of environmental carcinogens, seriously endangering human health and ecological safety, and the hydroxylpolycyclic aromatic hydrocarbons (OH-PAHs) in human urine are considered as the main biomarkers to evaluate the exposure levels of PAHs in human body. Therefore, it is necessary to develop an accurate and sensitive method for the determination of urinary OH-PAHs. Herein, we proposed electromembrane extraction (EME) as a simple, effective and ecofriendly sample pretreatment technique for selective extraction, purification and enrichment of four typical OH-PAHs (2-naphthol, 2- and 3-phenanthrol, 2-hydroxyfluorene) in human urine for the first time. Under the optimum conditions, an analytical method of EME coupled with HPLC was established, which provided wide linear ranges for four OH-PAHs from 1 to 500 ng mL-1 with low LODs of 0.05-0.3 ng mL-1. The average recoveries of four OH-PAHs at three spiked levels in human urine were 81.6-102.5% with RSDs all below 9.4%. The present method has been successfully applied for the sensitive determination of trace four OH-PAHs in urine samples from non-smokers and smokers with a maximum concentration of 2.24 and 3.56 ng mL-1, respectively, which showed a great potential for the analysis of trace OH-PAHs in biological samples.
Collapse
Affiliation(s)
- Haidong Gao
- Institute of Business Scientific, Henan Academy of Sciences, Wenhua Road #87, Zhengzhou, Henan 450003, China
| | - Shucai Gao
- Institute of Business Scientific, Henan Academy of Sciences, Wenhua Road #87, Zhengzhou, Henan 450003, China
| | - Ming Lv
- Institute of Business Scientific, Henan Academy of Sciences, Wenhua Road #87, Zhengzhou, Henan 450003, China
| | - Yeru Liu
- Institute of Business Scientific, Henan Academy of Sciences, Wenhua Road #87, Zhengzhou, Henan 450003, China
| | - Jingjing Yao
- Institute of Business Scientific, Henan Academy of Sciences, Wenhua Road #87, Zhengzhou, Henan 450003, China
| | - Hongwei Liu
- Institute of Business Scientific, Henan Academy of Sciences, Wenhua Road #87, Zhengzhou, Henan 450003, China
| | - Fayun Wang
- Institute of Business Scientific, Henan Academy of Sciences, Wenhua Road #87, Zhengzhou, Henan 450003, China
| | - Mantang Chen
- Zhengzhou Tobacco Research Institute of CNTC, Fengyang Street #2, Zhengzhou, Henan 450001, China.
| | - Libin Wan
- Institute of Business Scientific, Henan Academy of Sciences, Wenhua Road #87, Zhengzhou, Henan 450003, China.
| |
Collapse
|
2
|
Ballester-Caudet A, García-García S, Del Nogal Sánchez M, Rodríguez-Gonzalo E, Pérez Pavón JL. Development of a non-separative screening strategy based on mass spectrometry for the semi-quantification of urinary polycyclic aromatic hydrocarbon metabolites. Talanta 2024; 279:126590. [PMID: 39053363 DOI: 10.1016/j.talanta.2024.126590] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Revised: 07/16/2024] [Accepted: 07/18/2024] [Indexed: 07/27/2024]
Abstract
A fast and non-separative screening strategy is presented for the analysis of five urinary metabolites of polycyclic aromatic hydrocarbons (PAHs), namely 2-naphthol, 1-acenaphthenol, 2-hydroxyfluorene, 9-phenanthrol and 1-hydroxypyrene. These hydroxylated derivatives (OH-PAHs) were subjected to enzymatic hydrolysis and were extracted from urine using a liquid-liquid extraction (LLE). The profile signals were obtained by direct injection of the sample into a programmed temperature vaporizer coupled to a quadrupole mass spectrometer via a deactivated fused silica tubing (PTV-qMS). Semi-quantitative determination was carried out by means of partial least squares regression (PLS1) using urine samples free of the analytes and spiked at several uncorrelated concentration levels. The multivariate calibration models worked satisfactorily, with errors ranging between 30 and 33 % for all the analytes except for 1-acenaphthenol that provided an error of 39 % when external validation set was considered. The repeatability and reproducibility, expressed as relative standard deviation (RSD), were ranged between 8-16 % and 11-18 %, respectively. The proposed method could be a useful tool for semi-quantification purposes of five OH-PAHs in urine samples, identifying positive samples for subsequent further chromatographic separation (confirmation), thus saving time and costs.
Collapse
Affiliation(s)
- Ana Ballester-Caudet
- Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Ciencias Químicas, Universidad de Salamanca, 37008, Salamanca, Spain
| | - Samuel García-García
- Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Ciencias Químicas, Universidad de Salamanca, 37008, Salamanca, Spain
| | - Miguel Del Nogal Sánchez
- Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Ciencias Químicas, Universidad de Salamanca, 37008, Salamanca, Spain.
| | - Encarnación Rodríguez-Gonzalo
- Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Ciencias Químicas, Universidad de Salamanca, 37008, Salamanca, Spain
| | - José Luis Pérez Pavón
- Departamento de Química Analítica, Nutrición y Bromatología, Facultad de Ciencias Químicas, Universidad de Salamanca, 37008, Salamanca, Spain
| |
Collapse
|
3
|
Gu H, Li J. Mathematical model of ion chronogram from in-tube solid-phase microextraction device coupled with mass spectrometry and optimization framework. J Chromatogr A 2024; 1731:465167. [PMID: 39033707 DOI: 10.1016/j.chroma.2024.465167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2024] [Revised: 07/08/2024] [Accepted: 07/13/2024] [Indexed: 07/23/2024]
Abstract
A mathematical description and experimental outputs exhibited that an ion chronogram from an in-tube solid-phase microextraction (SPME) device linked with mass spectrometry (in-tube-SPME-MS) generally appears as a right-skew unimodal signal with a heavy right tail. Analogous to liquid chromatography coupled with mass spectrometry (LC-MS), in-tube-SPME-MS can utilize the area under its produced ion chronogram for regression analysis and has been shown to be a potential approach for fast quantification of analyte. Different level of unimodity of signal in the ion chronogram could positively or negatively affect the choice of the area used for quantification and finally impact on analysis sensitivity and time efficiency of in-tube-SPME-MS. In the paper, we showed that different in-tube SPME design choices and elution experimental setups produce ion chronograms with controllable varying unimodal peak shape patterns. An improved mathematical model was built based on the plate theory of chromatography and the Van Deemter equation to quantitatively describe the elution process from in-tube-SPME device. A computer simulation was implemented to predict ion chronograms and the results were compared with experimental ion chronograms to show the effectiveness of the model. An optimization framework was further presented based on the model to identify optimal device designs (length and diameter of device) and experimental parameters (flow rate) to track targeted ion chronograms with "desired" peak shape patterns. Empirical elution experiments with the in-tube SPME devices adopting optimized geometric parameters and optimal experimental setups confirmed the consistency between the experimental ion chronograms and the numerical simulations to a certain level.
Collapse
Affiliation(s)
- Hao Gu
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China.
| | - Jiwen Li
- Hanbot Institute, Yovole Networks Inc., Shanghai 200433, China.
| |
Collapse
|
4
|
Gu H, Li J, Liang Q, Xu W. Solid phase microextraction device coupled with miniature mass spectrometry and mathematical model of its ion chronogram. Talanta 2024; 271:125651. [PMID: 38262130 DOI: 10.1016/j.talanta.2024.125651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 01/04/2024] [Accepted: 01/06/2024] [Indexed: 01/25/2024]
Abstract
Modern solid phase microextraction (SPME) device linked with mass spectrometry (SPME-MS) has evolved from producing ion chronogram as flat noisy signal to as unimodal-like signal. We designed a SPME device, which is closer in morphology to LC column, linked it with a miniature mass spectrometer (SPME-Mini MS), and proposed a mathematical model that elution of compound from the SPME device is equivalent to overlay of elution of the compound from the infinite LC columns with the lengths between 0 and the length of the device and it can generate an ion chronogram as right-skew unimodal signal. Rhodamine B as analyte was used for experimental verification and its unimodal signal was used to fit the parameters of a computer simulation program based on the model. The experimental results and simulations empirically cross-confirmed that SPME-Mini MS can generate ion chronogram as clean right-skew unimodal signal. Furthermore, the SPME-Mini MS system was used for quantitative analysis of psychotropic drugs (i.e. risperidone and aripiprazole) in artificial urine. The results preliminarily demonstrated that the system can utilize area under unimodal signal for quantitative analysis and has potential to be applied for on-site, fast and accurate quantification of drugs and other compounds.
Collapse
Affiliation(s)
- Hao Gu
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China.
| | - Jiwen Li
- Hanbot Institute, Yovole Networks Inc, Shanghai, 200433, China.
| | - Qiong Liang
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| | - Wei Xu
- School of Life Science, Beijing Institute of Technology, Beijing 100081, China
| |
Collapse
|
5
|
Mirabelli MF. Direct Coupling of SPME to Mass Spectrometry. EVOLUTION OF SOLID PHASE MICROEXTRACTION TECHNOLOGY 2023:290-314. [DOI: 10.1039/bk9781839167300-00290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Abstract
Solid-phase microextraction devices are normally analyzed by gas or liquid chromatography. Their use has become increasingly widespread since their introduction in 1990, and nowadays most analytical laboratories use or have used SPME as an efficient and green method to perform analyte extraction and sample clean-up in one step. The SPME technique is intrinsically flexible, and allows for a high degree of optimization with regard to the extracting phase, as well as the way sample is analyzed. Since its introduction, researchers have been trying different ways to transfer analytes extracted from the solid phase to a mass spectrometer, with the aim to increase throughput and reduce solvent, gas usage and costs associated with conventional chromatographic techniques. Furthermore, but not less important, for pure fun of developing new, more efficient and sensitive analytical strategies! This chapter aims at providing a comprehensive overview of the most relevant non-chromatographic mass spectrometric approaches developed for SPME. Technical aspects of each SPME-MS approach will be discussed, highlighting their advantages, disadvantages and future potential developments. Particular emphasis will be given on the most recent direct coupling approaches using novel ionization approaches, and a concise overview of the existing applications will also be provided.
Collapse
|
6
|
Jin R, Liu G, Zhou X, Zhang Z, Lin B, Liu Y, Qi Z, Zheng M. Analysis of polycyclic aromatic hydrocarbon derivatives in environment. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.116942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
7
|
García-García S, Matilla-González H, Peña J, del Nogal Sánchez M, Casas-Ferreira AM, Pérez Pavón JL. Determination of Hydroxy Polycyclic Aromatic Hydrocarbons in Human Urine Using Automated Microextraction by Packed Sorbent and Gas Chromatography-Mass Spectrometry. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph192013089. [PMID: 36293669 PMCID: PMC9602966 DOI: 10.3390/ijerph192013089] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 10/05/2022] [Accepted: 10/10/2022] [Indexed: 05/10/2023]
Abstract
A fast methodology for the determination of monohydroxy polycyclic aromatic hydrocarbons in human urine using a fully automated microextraction by packed sorbent coupled to a gas chromatograph-mass spectrometer is reported. Sample preparation requires simple hydrolysis, centrifugation, filtration, and dilution. The method does not require a derivatization step prior to analysis with gas chromatography and allows the measurement of up to three samples per hour after hydrolysis. Quantitation is carried out by a one-point standard addition allowing the determination of 6 analytes with good limits of detection (10.1-39.6 ng L-1 in water and 0.5-19.4 µg L-1 in urine), accuracy (88-110%) and precision (2.1-23.4% in water and 5.1-19.0% in urine) values. This method has been successfully applied to the analysis of six urine samples (three from smoker and three from non-smoker subjects), finding significant differences between both types of samples. Results were similar to those found in the literature for similar samples, which proves the applicability of the methodology.
Collapse
|
8
|
Tan S, Wang J, Li M, Yin X, Gao X, Li C, Jiang Y, Dai X, Gong X, Fang X. Direct analysis of hydroxylated polycyclic aromatic hydrocarbons in biological samples with complex matrices using polarity-reversed nanoelectrospray ionization. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9237. [PMID: 34904282 DOI: 10.1002/rcm.9237] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 11/18/2021] [Accepted: 12/05/2021] [Indexed: 06/14/2023]
Abstract
RATIONALE Polycyclic aromatic hydrocarbons (PAHs) are a class of environmental contaminants with carcinogenic effect drawing worldwide attention. PAHs can be converted into hydroxylated PAHs (OH-PAHs) through metabolic processes. Thus, they are commonly considered as an important class of biomarkers of PAH exposure. However, direct analysis of related metabolites of these environmental pollutants in biological samples using mass spectrometry is still challenging because of matrix effect and ion suppression during nanoelectrospray ionization (nano-ESI). METHODS In our previous work, a polarity-reversed nanoelectrospray ionization (PR-nESI) technique was developed for the analysis of biomolecules in complex matrices. In this work, we further optimized PR-nESI for direct and sensitive analysis of OH-PAHs in different samples under severe salt interference in negative polarity. RESULTS Compared with conventional nano-ESI, the optimized PR-nESI method realized sensitive detection of 1-naphthol in samples with a concentration of salt up to millimolar level. The signal-to-noise ratio (S/N) of OH-PAHs was increased by 1-2 orders of magnitude compared with conventional nano-ESI. Six different OH-PAHs were successfully detected with high S/N ratio using PR-nESI. PR-nESI was further successfully applied in the analysis of OH-PAHs in spiked fetal blood serum, human urine, and single-cell samples. For environmentally exposed subjects, the detections of OH-PAHs in single-cell samples and urines from human smokers were successfully conducted. CONCLUSION The optimized PR-nESI method was successfully applied for the sensitive analysis of OH-PAHs in complex biological samples with severe salt effects. Based on the present study, PR-nESI can have a promising prospect for the sensitive analysis of other metabolites of environmental pollutants in negative polarity.
Collapse
Affiliation(s)
- Siyuan Tan
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People's Republic of China
| | - Juduo Wang
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People's Republic of China
| | - Manli Li
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People's Republic of China
| | - Xinchi Yin
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People's Republic of China
| | - Xiaomei Gao
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People's Republic of China
| | - Chang Li
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People's Republic of China
| | - You Jiang
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People's Republic of China
| | - Xinhua Dai
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People's Republic of China
| | - Xiaoyun Gong
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People's Republic of China
| | - Xiang Fang
- Technology Innovation Center of Mass Spectrometry for State Market Regulation, Center for Advanced Measurement Science, National Institute of Metrology, Beijing, People's Republic of China
| |
Collapse
|
9
|
Zhang Q, Zhang X, Yang B, Liu S, Wen M, Bao L, Jiang L. Development of a highly efficient in-tube solid-phase microextraction system coupled with UHPLC-MS/MS for analyzing trace hydroxyl polycyclic aromatic hydrocarbons in biological samples. J Sep Sci 2021; 45:919-928. [PMID: 34923746 DOI: 10.1002/jssc.202100751] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 12/08/2021] [Accepted: 12/11/2021] [Indexed: 12/20/2022]
Abstract
Hydroxyl polycyclic aromatic hydrocarbons are considered active mutagenic and carcinogenic substances and are found in extremely low levels (ng/g) in biological samples. As a result, their determination in urine and blood samples is challenging, and a sensitive and effective method for the analysis of trace hydroxyl polycyclic aromatic hydrocarbons in complex biological matrices is required. In this work, a novel macroporous in-tube solid-phase microextraction monolith was prepared via a thiol-yne click reaction, and a highly efficient analytical method based on in-tube solid-phase microextraction coupled with UHPLC-MS/MS was developed to determine hydroxyl polycyclic aromatic hydrocarbons with low detection limits of 0.137-11.0 ng/L in complex biological samples. Four hydroxyl polycyclic aromatic hydrocarbons, namely, 2-hydroxyanthraquinone, 1-hydroxypyrene, 1,8-dihydroxyanthraquinone, and 6-hydroxychrysene, were determined in the urine samples of smokers, non-smokers, and whole blood samples of mice. Satisfactory recoveries were achieved in the range of 83.1-113% with relative standard deviations of 3.2-9.7%. It was found that implementation of the macroporous monolith gave a highly efficient approach for enriching trace hydroxyl polycyclic aromatic hydrocarbons in biological samples.
Collapse
Affiliation(s)
- Qianchun Zhang
- School of Biology and Chemistry, Key Laboratory for Analytical Science of Food and Environment Pollution of Qian Xi Nan, Xingyi Normal University for Nationalities, Xingyi, P. R. China
| | - Xiaolan Zhang
- School of Biology and Chemistry, Key Laboratory for Analytical Science of Food and Environment Pollution of Qian Xi Nan, Xingyi Normal University for Nationalities, Xingyi, P. R. China
| | - Bingnian Yang
- School of Biology and Chemistry, Key Laboratory for Analytical Science of Food and Environment Pollution of Qian Xi Nan, Xingyi Normal University for Nationalities, Xingyi, P. R. China
| | - Shan Liu
- School of Biology and Chemistry, Key Laboratory for Analytical Science of Food and Environment Pollution of Qian Xi Nan, Xingyi Normal University for Nationalities, Xingyi, P. R. China
| | - Ming Wen
- School of Biology and Chemistry, Key Laboratory for Analytical Science of Food and Environment Pollution of Qian Xi Nan, Xingyi Normal University for Nationalities, Xingyi, P. R. China
| | - Linchun Bao
- Clinical Laboratory, Qian Xi Nan People's Hospital, Xingyi, P. R. China
| | - Li Jiang
- School of Biology and Chemistry, Key Laboratory for Analytical Science of Food and Environment Pollution of Qian Xi Nan, Xingyi Normal University for Nationalities, Xingyi, P. R. China
| |
Collapse
|
10
|
Simultaneous determination of multiple isomeric hydroxylated polycyclic aromatic hydrocarbons in urine by using ultra-high performance liquid chromatography tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1184:122983. [PMID: 34655894 DOI: 10.1016/j.jchromb.2021.122983] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 10/02/2021] [Accepted: 10/04/2021] [Indexed: 11/24/2022]
Abstract
Monitoring the level of hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) in urine is the key to exploring human metabolic changes and comprehensive potential toxicity of PAHs. The OH-PAHs with isomeric structure have different biological functions, indicating that their quantification is indispensable. However, the quantitation method is still dissatisfactory due to the poor separation of these isomeric OH-PAHs. The current study established a ultra-high performance liquid chromatography (UHPLC) tandem mass spectrometry (MS) method to complete the simultaneous determination of 17 OH-PAHs, including two naphthalene metabolites (1-hydroxynaphthalene, 2-hydroxynaphthalene), two fluorene metabolites (2-hydroxyfluorene, 3-hydroxyfluorene), five phenanthrene metabolites (1-hydroxyphenanthrene, 2-hydroxyphenanthrene, 3-hydroxyphenanthrene, 4-hydroxyphenanthrene, 9-hydroxyphenanthrene), a pyrene metabolite (1-hydroxypyrene), five chrysene metabolites (1-hydroxychrysene, 2-hydroxychrysene, 3-hydroxychrysene, 4-hydroxychrysene, 6-hydroxychrysene) and two benzo[a]pyrene metabolites (3-hydroxybenzo[a]pyrene, 9-hydroxybenzo[a]pyrene). The method validation results showed good selectivity, linearity (r2 > 0.999), inter-day and intra-day precision (relative standard deviation (RSD) < 5.5% and RSD < 6.3%), stability (RSD < 19.3%), matrix effect (-8.3%-11.5%) and recovery (65.9%-116.2%). This method is convenient, sensitive and efficient, saving expensive materials and complicated derivatization procedures. The practical applicability of developed approach was also tested in urine samples to identify potential biomarkers of PAHs exposure in humans, and a great compromise was obtained between recoveries and extract convenience. The developed approach may be widely utilized for specific determination of OH-PAHs with isomer structure in urine samples. It is expected that the application of this method may provide powerful references for PAHs exposure assessment.
Collapse
|
11
|
Jouyban A, Nemati M, Farazajdeh MA, Alizadeh Nabil AA, Afshar Mogaddam MR. A polymer-based dispersive solid phase extraction combined with deep eutectic solvent based-dispersive liquid-liquid microextraction for the determination of four hydroxylated polycyclic aromatic hydrocarbons from urine samples. J Sep Sci 2021; 44:4025-4036. [PMID: 34459108 DOI: 10.1002/jssc.202100269] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 07/31/2021] [Accepted: 08/23/2021] [Indexed: 11/07/2022]
Abstract
A new and efficient extraction procedure was proposed and used for the simultaneous extraction of four hydroxylated metabolites polycyclic aromatic hydrocarbons from urine samples. The extraction procedure was started by dissolving an organic polymer into a water-miscible organic solvent (iso-propanol) and its injection into the sample solution. The sorbent was re-precipitated in all parts of the solution as tiny particles and the analytes were adsorbed onto the sorbent. After that, the sorbent was separated and the adsorbed analytes were eluted by choline chloride: dichloroacetic acid deep eutectic solvent. The elution solvent was mixed with choline chloride-3,3-dimethyl butyric acid deep eutectic solvent and the mixture was applied in dispersive liquid-liquid microextraction procedure for more concentration of the analytes. After optimization, the method validation was followed according to International Council Harmonization guidelines and the results showed that wide linear ranges (26-500 000 ng/L) and low limits of detection (3.6-7.2 ng/L) and quantification (11-26 ng/L) were obtained. Satisfactory enrichment factors (435-475) and extraction recoveries (87-95%), and acceptable relative standard deviations (equal or less than 8.6%) were obtained. Finally, the introduced method was successfully applied for determination of the analytes in urine samples obtained from tobacco smokers.
Collapse
Affiliation(s)
- Abolghasem Jouyban
- Food and Drug Safety Research Center, Tabriz University of Medical Science, Tabriz, Iran
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Science, Tabriz, Iran
| | - Mahboob Nemati
- Food and Drug Safety Research Center, Tabriz University of Medical Science, Tabriz, Iran
- Halal Research Center, Ministry of Health and Medical Education, Tehran, Iran
| | - Mir Ali Farazajdeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
- Engineering Faculty, Near East University, Mersin, Turkey
| | | | - Mohammad Reza Afshar Mogaddam
- Food and Drug Safety Research Center, Tabriz University of Medical Science, Tabriz, Iran
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Science, Tabriz, Iran
| |
Collapse
|
12
|
He XQ, Cui YY, Zhang Y, Yang CX. Fabrication of magnetic polydopamine@naphthyl microporous organic network nanosphere for efficient extraction of hydroxylated polycyclic aromatic hydrocarbons and p-nitrophenol from wastewater samples. J Chromatogr A 2021; 1651:462347. [PMID: 34166861 DOI: 10.1016/j.chroma.2021.462347] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 05/28/2021] [Accepted: 06/08/2021] [Indexed: 02/06/2023]
Abstract
Herein, we report the fabrication of a novel, well-defined core-double-shell-structured magnetic Fe3O4@polydopamine@naphthyl microporous organic network (MON), Fe3O4@PDA@NMON, for the efficient magnetic extraction of hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and p-nitrophenol (p-Npn) from wastewater samples. The hierarchical nanospheres were designed and constructed with the Fe3O4 nanoparticle core, the inner shell of a polydopamine (PDA) layer, and the outer shell of a porous naphthyl MON (NMON) coating, allowing efficient and synergistic extraction of OH-PAHs and p-Npn via hydrophobic, hydrogen bonding, and π-π interactions. The Fe3O4@PDA@NMON nanospheres were well characterized and employed as an efficient sorbent for magnetic solid-phase extraction (MSPE) coupled with high performance liquid chromatography (HPLC) for analyzing of OH-PAHs and p-Npn. Under optimal conditions, the Fe3O4@PDA@NMON-based-MSPE-HPLC-UV method afforded wide linear range (0.18-500 μg L-1), low limits of detection (0.070 μg L-1 for p-Npn, 0.090 μg L-1 for 2-OH-Nap, 0.090 μg L-1 for 9-OH-Fluo and 0.055 μg L-1 for 9-OH-Phe, respectively), large enrichment factors (92.6-98.4), good precisions (intra-day and inter-day relative standard deviations (RSDs); <6.4%, n=6) and less consumption of the adsorbent. Furthermore, trace OH-PAHs and p-Npn with concentrations of 0.29-0.80 μg L-1 were successfully detected in various wastewater samples. Fe3O4@PDA@NMON also functioned as a good adsorbent to enrich a wide scope of trace contaminants containing hydrogen bonding sites and aromatic structures, highlighting the potential of functional MONs in sample pretreatment.
Collapse
Affiliation(s)
- Xin-Qiao He
- College of Chemistry, Research Center for Analytical Sciences, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Nankai University, Tianjin 300071, China
| | - Yuan-Yuan Cui
- College of Chemistry, Research Center for Analytical Sciences, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Nankai University, Tianjin 300071, China
| | - Yan Zhang
- College of Chemistry, Research Center for Analytical Sciences, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Nankai University, Tianjin 300071, China
| | - Cheng-Xiong Yang
- College of Chemistry, Research Center for Analytical Sciences, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Nankai University, Tianjin 300071, China.
| |
Collapse
|
13
|
Sun Z, Li J, Wu J, Zou X, Ho CT, Liang L, Yan X, Zhou X. Rapid qualitative and quantitative analysis of strong aroma base liquor based on SPME-MS combined with chemometrics. FOOD SCIENCE AND HUMAN WELLNESS 2021. [DOI: 10.1016/j.fshw.2021.02.031] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
14
|
Mikhail IE, Tehranirokh M, Gooley AA, Guijt RM, Breadmore MC. Hyphenated sample preparation-electrospray and nano-electrospray ionization mass spectrometry for biofluid analysis. J Chromatogr A 2021; 1646:462086. [PMID: 33892255 DOI: 10.1016/j.chroma.2021.462086] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 03/18/2021] [Accepted: 03/19/2021] [Indexed: 10/21/2022]
Abstract
Stand-alone electrospray ionization mass spectrometry (ESI-MS) has been advancing through enhancements in throughput, selectivity and sensitivity of mass spectrometers. Unlike traditional MS techniques which usually require extensive offline sample preparation and chromatographic separation, many sample preparation techniques are now directly coupled with stand-alone MS to enable outstanding throughput for bioanalysis. In this review, we summarize the different sample clean-up and/or analyte enrichment strategies that can be directly coupled with ESI-MS and nano-ESI-MS for the analysis of biological fluids. The overview covers the hyphenation of different sample preparation techniques including solid phase extraction (SPE), solid phase micro-extraction (SPME), slug flow micro-extraction/nano-extraction (SFME/SFNE), liquid extraction surface analysis (LESA), extraction electrospray, extraction using digital microfluidics (DMF), and electrokinetic extraction (EkE) with ESI-MS and nano-ESI-MS.
Collapse
Affiliation(s)
- Ibraam E Mikhail
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Department of Analytical Chemistry, Faculty of Pharmacy, Mansoura University, 35516, Egypt
| | - Masoomeh Tehranirokh
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), Australia; Trajan Scientific and Medical, Ringwood, VIC, 3134, Australia
| | - Andrew A Gooley
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), Australia; Trajan Scientific and Medical, Ringwood, VIC, 3134, Australia
| | - Rosanne M Guijt
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), Australia; Centre for Regional and Rural Futures, Deakin University, Geelong, VIC, 3220, Australia
| | - Michael C Breadmore
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.
| |
Collapse
|
15
|
Shi Y, Huang S, Kuang Y, Chen Z, Guo J, Cui S, Zheng J, Ouyang G. Facile fabrication of composited solid phase microextraction thin membranes for sensitive detections of trace hydroxylated polycyclic aromatic hydrocarbons in human urine. Anal Chim Acta 2021; 1158:338422. [PMID: 33863405 DOI: 10.1016/j.aca.2021.338422] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 03/11/2021] [Accepted: 03/16/2021] [Indexed: 12/11/2022]
Abstract
Solid phase microextraction (SPME) has potential to be used for the high-performance enrichments of hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs), which are important biomarkers of PAH exposure. By choosing suitable adsorbent, it is conducive to fabricate new-type of SPME device for improved extraction efficiencies towards OH-PAHs. In this study, a novel method of surface solvent evaporation has been proposed to fabricate SPME thin membrane, integrating the advantages of polydimethylsiloxane (PDMS) and different porous adsorbents. The powdery metal organic framework (Uio66-NH2), porous polymer (powdery polymer aerogel, PPA) and ordered mesoporous carbon (OMC) have been chosen as typical adsorbents and fabricated as thin membranes successfully, indicating the universality of the proposed method for membrane fabrication. Comparing the extraction efficiencies of three prepared membranes towards OH-PAHs, the OMC-PDMS membrane has demonstrated best enrichment efficiencies. The OMC-PDMS membrane was used for the enrichments of trace OH-PAHs in human urine of both smokers and nonsmokers, combining with liquid chromatographic tandem mass spectrometry (LC-MS/MS). The detection limits were in the range of 0.15-0.39 ng L-1, and satisfactory recoveries were found to be 82.1%-115%. It can be seen that the universal strategy to fabricate SPME membrane is helpful to achieve broad-spectrum or selective enrichments of target analytes from complex matrix by simple modulation of membrane components.
Collapse
Affiliation(s)
- Yueru Shi
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Shuyao Huang
- Instrumental Analysis and Research Center, Sun Yat-sen University, Guangzhou, 510275, China
| | - Yixin Kuang
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Zexun Chen
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Jing Guo
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China
| | - Shufen Cui
- Department of Biological Applied Engineering, Shenzhen Key Laboratory of Fermentation Purification and Analysis, Shenzhen Polytechnic, Shenzhen, 518055, China.
| | - Juan Zheng
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China.
| | - Gangfeng Ouyang
- MOE Key Laboratory of Aquatic Product Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou, 510275, China; Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals, Guangdong Provincial Engineering Research Center for Ambient Mass Spectrometry, Institute of Analysis, Guangdong Academy of Sciences (China National Analytical Center Guangzhou), 100 Xianlie Middle Road, Guangzhou, 510070, China; Chemistry College, Center of Advanced Analysis and Gene Sequencing, Zhengzhou University, Kexue Avenue 100, Zhengzhou, 450001, China
| |
Collapse
|
16
|
Daryanavard SM, Zolfaghari H, Abdel-Rehim A, Abdel-Rehim M. Recent applications of microextraction sample preparation techniques in biological samples analysis. Biomed Chromatogr 2021; 35:e5105. [PMID: 33660303 DOI: 10.1002/bmc.5105] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/26/2021] [Accepted: 02/05/2021] [Indexed: 12/11/2022]
Abstract
Analysis of biological samples is affected by interfering substances with chemical properties similar to those of the target analytes, such as drugs. Biological samples such as whole blood, plasma, serum, urine and saliva must be properly processed for separation, purification, enrichment and chemical modification to meet the requirements of the analytical instruments. This causes the sample preparation stage to be of undeniable importance in the analysis of such samples through methods such as microextraction techniques. The scope of this review will cover a comprehensive summary of available literature data on microextraction techniques playing a key role for analytical purposes, methods of their implementation in common biological samples, and finally, the most recent examples of application of microextraction techniques in preconcentration of analytes from urine, blood and saliva samples. The objectives and merits of each microextration technique are carefully described in detail with respect to the nature of the biological samples. This review presents the most recent and innovative work published on microextraction application in common biological samples, mostly focused on original studies reported from 2017 to date. The main sections of this review comprise an introduction to the microextraction techniques supported by recent application studies involving quantitative and qualitative results and summaries of the most significant, recently published applications of microextracion methods in biological samples. This article considers recent applications of several microextraction techniques in the field of sample preparation for biological samples including urine, blood and saliva, with consideration for extraction techniques, sample preparation and instrumental detection systems.
Collapse
Affiliation(s)
| | - Hesane Zolfaghari
- Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, Iran
| | - Abbi Abdel-Rehim
- Department of Chemical Engineering and Biotechnology, Cambridge University, Cambridge, UK
| | - Mohamed Abdel-Rehim
- Functional Materials Division, Department of Applied Physics, School of Engineering Sciences, KTH Royal Institute of Technology, Stockholm, Sweden.,Department of Clinical Neuroscience, Centre for Psychiatry Research, Karolinska Institutet, Solna, Sweden
| |
Collapse
|
17
|
Vasconcelos PHM, Camelo ALM, de Lima ACA, do Nascimento HO, Vidal CB, do Nascimento RF, Lopes GS, Longhinotti E. Chemometric tools applied to optimize a fast solid-phase microextraction method for analysis of polycyclic aromatic hydrocarbons in produced water. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:8012-8021. [PMID: 33044696 DOI: 10.1007/s11356-020-10881-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 09/15/2020] [Indexed: 06/11/2023]
Abstract
Chemometric tools are powerful strategies to efficiently optimize many processes. These tools were employed to optimize a fast-solid phase microextraction procedure, which was used for the analysis of polycyclic aromatic hydrocarbons (PAHs) in oil-based produced water using a Headspace-Solid Phase Microextraction technique (HS-SPME/GC-MS). This optimization was achieved with a 24 factorial design approach, where the final conditions for this extraction procedure were 10 μg L-1, 1 h, 92 °C (at headspace), and 0.62 mol L-1 for PAHs concentration, fiber exposition to headspace, temperature, and NaCl concentration, respectively. The limit of detection (LOD) in this protocol ranged from 0.2 to 41.4 ng L-1, while recovery values from 67.65 to 113.10%. Besides that, relative standard deviation (RSD) were lower than 8.39% considering high molecular weight compounds. Moreover, the proposed methodology in this work does not require any previous treatment of the sample and allows to quantify a higher number of PAHs. Notably, naphthalene was the major PAHs compound quantified in all samples of the produced water at 99.99 μg L-1. Altogether, these results supported this methodology as a suitable analytical strategy for fast determination of PAHs in produced water from oil-based industry.
Collapse
Affiliation(s)
| | - André Luiz M Camelo
- Federal Institute of Education, Science and Technology of Ceará, Limoeiro do Norte, CE, 62930-000, Brazil
| | - Ari Clecius A de Lima
- Industrial Technology Center of Ceará Foundation (Núcleo de Tecnologia e Qualidade Industrial do Ceará - NUTEC), Fortaleza, CE, 60440-552, Brazil
| | - Hélio O do Nascimento
- Department of Analytical Chemistry and Physical Chemistry, Federal University of Ceará, Campus do Pici, Fortaleza, CE, 60440-900, Brazil
| | - Carla B Vidal
- Centro Universitario UniFanor, Campus Dunas, R. Antonio Gomes Guimaraes, 150, Papicu, Fortaleza, CE, 60191-195, Brazil
- Centro Universitário UniFametro, Campus Carneiro da Cunha, R. Carneiro da Cunha, 180, Jacarecanga, Fortaleza, CE, 60010-470, Brazil
| | - Ronaldo F do Nascimento
- Department of Analytical Chemistry and Physical Chemistry, Federal University of Ceará, Campus do Pici, Fortaleza, CE, 60440-900, Brazil.
| | - Gisele S Lopes
- Department of Analytical Chemistry and Physical Chemistry, Federal University of Ceará, Campus do Pici, Fortaleza, CE, 60440-900, Brazil
| | - Elisane Longhinotti
- Department of Analytical Chemistry and Physical Chemistry, Federal University of Ceará, Campus do Pici, Fortaleza, CE, 60440-900, Brazil.
| |
Collapse
|
18
|
Kim U, Karthikraj R. Solid‐phase microextraction for the human biomonitoring of environmental chemicals: Current applications and future perspectives. J Sep Sci 2020; 44:247-273. [DOI: 10.1002/jssc.202000830] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 10/18/2020] [Accepted: 11/13/2020] [Indexed: 01/09/2023]
Affiliation(s)
- Un‐Jung Kim
- Department of Earth & Environmental Sciences University of Texas at Arlington Arlington Texas USA
| | | |
Collapse
|
19
|
Jalili V, Barkhordari A, Ghiasvand A. Solid-phase microextraction technique for sampling and preconcentration of polycyclic aromatic hydrocarbons: A review. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104967] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
20
|
Yang Q, Bai Y, Qin GQ, Jia RY, Zhu W, Zhang D, Fang ZZ. Inhibition of UDP-glucuronosyltransferases (UGTs) by polycyclic aromatic hydrocarbons (PAHs) and hydroxy-PAHs (OH-PAHs). ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 263:114521. [PMID: 32283403 DOI: 10.1016/j.envpol.2020.114521] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Revised: 03/12/2020] [Accepted: 03/31/2020] [Indexed: 06/11/2023]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) are known as one of the ubiquitous environmental pollutants caused by unavoidable combustion of by-products. Despite decades of research on adverse health effects towards humans, the effects of PAHs and their hydroxylated metabolites (OH-PAHs) on UDP-glucuronosyltransferases (UGTs) remain unclear. This study aimed to investigate inhibitory effects with structure-dependence of 14 PAHs and OH-PAHs towards the activity of 7 isoforms of UGTs using in vitro recombinant UGTs-catalyzed glucuronidation of 4-methylumbelliferone (4-MU) as the probe reaction. PAHs and OH-PAHs showed inhibitory effects towards different UGT isoforms with different extents. For inhibition kinetics determination, 1-HONAP, 4-HOPHE, 9-HOPHE, and 1-HOPYR were utilized as the representative compounds, and UGT1A6, UGT1A9 and UGT2B7 were chosen as the three representative UGT isoforms. The inhibitory effects of 4-HOPHE, 9-HOPHE and 1-HOPYR on three above UGT isoforms were the same: UGT1A9>UGT1A6>UGT2B; for 1-HONAP, that is UGT1A6>UGT1A9>UGT2B. Molecular docking methods were utilized to find the activity cavity of UGT1A9 and UGT2B7 binding with 1-HONAP and 1-HOPYR. Hydrogen bonds and hydrophobic contacts were mainly contributors to their interactions. In vitro-in vivo extrapolation (IVIVE) showed that high in vivo inhibition possibility exists for the inhibition of OH-PAHs on UGTs. All the results provide a novel viewpoint for an explanation of the toxicity of PAHs and OH-PAHs.
Collapse
Affiliation(s)
- Qiaoyun Yang
- Tianjin Key Laboratory of Environment, Nutrition and Public Health, Tianjin 300070, PR China; Department of Occupational and Environmental Health, School of Public Health, Tianjin Medical University, Tianjin 300070, PR China; National Demonstration Center for Experimental Preventive Medicine Education (Tianjin Medical University), Tianjin 300070, PR China
| | - Yu Bai
- Department of Toxicology and Sanitary Chemistry, School of Public Health, Tianjin Medical University, Tianjin 300070, PR China
| | - Guo-Qiang Qin
- Department of Toxicology and Sanitary Chemistry, School of Public Health, Tianjin Medical University, Tianjin 300070, PR China
| | - Ruo-Yong Jia
- Department of Toxicology and Sanitary Chemistry, School of Public Health, Tianjin Medical University, Tianjin 300070, PR China
| | - Weihua Zhu
- Department of Hepatobiliary Surgery, Peking University People's Hospital, Beijing 100044, PR China
| | - Dafang Zhang
- Department of Hepatobiliary Surgery, Peking University People's Hospital, Beijing 100044, PR China
| | - Zhong-Ze Fang
- Tianjin Key Laboratory of Environment, Nutrition and Public Health, Tianjin 300070, PR China; Department of Toxicology and Sanitary Chemistry, School of Public Health, Tianjin Medical University, Tianjin 300070, PR China; National Demonstration Center for Experimental Preventive Medicine Education (Tianjin Medical University), Tianjin 300070, PR China.
| |
Collapse
|
21
|
Use of a pH-sensitive polymer in a microextraction and preconcentration method directly combined with high-performance liquid chromatography. J Chromatogr A 2020; 1619:460910. [DOI: 10.1016/j.chroma.2020.460910] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 01/09/2020] [Accepted: 01/21/2020] [Indexed: 12/21/2022]
|
22
|
Jinadasa BKKK, Monteau F, Morais S. Critical review of micro-extraction techniques used in the determination of polycyclic aromatic hydrocarbons in biological, environmental and food samples. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2020; 37:1004-1026. [PMID: 32186468 DOI: 10.1080/19440049.2020.1733103] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Polycyclic Aromatic Hydrocarbons (PAHs) are ubiquitous environmental contaminants and their accurate determination is very important to human health and environment safety. In this review, sorptive-based micro-extraction techniques [such as Solid-Phase Micro-extraction (SPME), Stir Bar Sorptive Extraction (SBSE), Micro-extraction in Packed Sorbent (MEPS)] and solvent-based micro-extraction [Membrane-Mediated Liquid-Phase Micro-extraction (MM-LPME), Dispersive Liquid-Liquid Micro-extraction (DLLME), and Single Drop Micro-extraction (SDME)] developed for quantification of PAHs in environmental, biological and food samples are reviewed. Moreover, recent micro-extraction techniques that have been coupled with other sample extraction strategies are also briefly discussed. The main objectives of these micro-extraction techniques are to perform extraction, pre-concentration and clean up together as one step, and the reduction of the analysis time, cost and solvent following the green chemistry guidelines.
Collapse
Affiliation(s)
- B K K K Jinadasa
- Laboratoire D'étude Des Résidus Et Contaminants Dans Les Aliments (LABERCA), Nantes-Atlantic National College of Veterinary Medicine, Food Science, and Engineering (ONIRIS) , Nantes, France
| | - Fabrice Monteau
- Laboratoire D'étude Des Résidus Et Contaminants Dans Les Aliments (LABERCA), Nantes-Atlantic National College of Veterinary Medicine, Food Science, and Engineering (ONIRIS) , Nantes, France
| | - Simone Morais
- REQUIMTE-LAQV, Instituto Superior De Engenharia Do Porto, Instituto Politécnico Do Porto , Porto, Portugal
| |
Collapse
|
23
|
Guo X, Bai H, Ma X, Li J, Ren Y, Ouyang Z, Ma Q. Online coupling of an electrochemically fabricated solid-phase microextraction probe and a miniature mass spectrometer for enrichment and analysis of chemical contaminants in infant drinks. Anal Chim Acta 2020; 1098:66-74. [DOI: 10.1016/j.aca.2019.11.021] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 11/06/2019] [Accepted: 11/11/2019] [Indexed: 12/15/2022]
|
24
|
Swiner DJ, Jackson S, Burris BJ, Badu-Tawiah AK. Applications of Mass Spectrometry for Clinical Diagnostics: The Influence of Turnaround Time. Anal Chem 2020; 92:183-202. [PMID: 31671262 PMCID: PMC7896279 DOI: 10.1021/acs.analchem.9b04901] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
This critical review discusses how the need for reduced clinical turnaround times has influenced chemical instrumentation. We focus on the development of modern mass spectrometry (MS) and its application in clinical diagnosis. With increased functionality that takes advantage of novel front-end modifications and computational capabilities, MS can now be used for non-traditional clinical analyses, including applications in clinical microbiology for bacteria differentiation and in surgical operation rooms. We summarize here recent developments in the field that have enabled such capabilities, which include miniaturization for point-of-care testing, direct complex mixture analysis via ambient ionization, chemical imaging and profiling, and systems integration.
Collapse
Affiliation(s)
- Devin J. Swiner
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210
| | - Sierra Jackson
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210
| | - Benjamin J. Burris
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210
| | - Abraham K. Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210
| |
Collapse
|
25
|
Liu Y, Li Z, Zhang Z, Zhao T, Wang M, Wang X. Determination of Urinary Hydroxyl PAHs Using Graphene Oxide@Diatomite Based Solid-Phase Extraction and High-Performance Liquid Chromatography. Molecules 2019; 24:molecules24224186. [PMID: 31752256 PMCID: PMC6891718 DOI: 10.3390/molecules24224186] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Revised: 11/10/2019] [Accepted: 11/18/2019] [Indexed: 11/16/2022] Open
Abstract
A diatomite supported graphene oxide composite (GO@Dt–NH2) was fabricated and explored as a solid-phase extraction adsorbent coupled with high performance liquid chromatography to determine the trace hydroxyl polycyclic aromatic hydrocarbons (2-hydroxy-naphthalene, 2-hydroxy-fluorene, 1-hydroxy-phenanthrene, and 1-hydroxy-pyrene) in urine samples. The fabricated composites were characterized by X-ray powder diffractometry and scanning electron microscopy. GO@Dt–NH2 offered enhanced adsorption affinity towards the analytes compared with the bare diatomite. The amount of graphene oxide and the factors affecting solid-phase extraction were investigated in detail. Under the optimized conditions, the method gave good linearity (0.30–200 ng/mL) and a low detection limit (0.10–0.15 ng/mL) for the hydroxyl polycyclic aromatic hydrocarbons. The average recovery for spiked urine samples with three levels ranged from 90.6% to 100%. The intra-day and inter-day relative standard deviations were in the range of 1.8–6.4% and 2.7–11.8%, respectively. Besides, the GO@Dt–NH2 provided enrichment factors of 18–20 and superior purification ability. The developed method was successfully applied to the determination of hydroxyl polycyclic aromatic hydrocarbons in urine samples from smoking volunteers.
Collapse
Affiliation(s)
| | | | | | | | - Manman Wang
- Correspondence: (M.W.); (X.W.); Tel.: +86-031-5880-5576 (M.W.); +86-031-5880-5576 (X.W.)
| | - Xuesheng Wang
- Correspondence: (M.W.); (X.W.); Tel.: +86-031-5880-5576 (M.W.); +86-031-5880-5576 (X.W.)
| |
Collapse
|
26
|
Recent Applications and Newly Developed Strategies of Solid-Phase Microextraction in Contaminant Analysis: Through the Environment to Humans. SEPARATIONS 2019. [DOI: 10.3390/separations6040054] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
The present review aims to describe the recent and most impactful applications in pollutant analysis using solid-phase microextraction (SPME) technology in environmental, food, and bio-clinical analysis. The covered papers were published in the last 5 years (2014–2019) thus providing the reader with information about the current state-of-the-art and the future potential directions of the research in pollutant monitoring using SPME. To this end, we revised the studies focused on the investigation of persistent organic pollutants (POPs), pesticides, and emerging pollutants (EPs) including personal care products (PPCPs), in different environmental, food, and bio-clinical matrices. We especially emphasized the role that SPME is having in contaminant surveys following the path that goes from the environment to humans passing through the food web. Besides, this review covers the last technological developments encompassing the use of novel extraction coatings (e.g., metal-organic frameworks, covalent organic frameworks, PDMS-overcoated fiber), geometries (e.g., Arrow-SPME, multiple monolithic fiber-SPME), approaches (e.g., vacuum and cold fiber SPME), and on-site devices. The applications of SPME hyphenated with ambient mass spectrometry have also been described.
Collapse
|
27
|
|
28
|
Li ZL, Li N, Du L, Wang YH, Fang B, Wang MM, Wang Q. Determination of trace hydroxyl polycyclic aromatic hydrocarbons in urine using graphene oxide incorporated monolith solid-phase extraction coupled with LC-MS/MS. J Sep Sci 2019; 42:3234-3242. [PMID: 31402580 DOI: 10.1002/jssc.201900540] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 08/07/2019] [Accepted: 08/07/2019] [Indexed: 01/24/2023]
Abstract
The biomonitoring of hydroxy polycyclic aromatic hydrocarbons in urine, as a direct way to access multiple exposures to polycyclic aromatic hydrocarbons, has raised great concerns due to their increasing hazardous health effects on humans. Solid-phase extraction is an effective and useful technique to preconcentrate trace analytes from biological samples. Here, we report a novel solid-phase extraction method using a graphene oxide incorporated monolithic syringe for the determination of six hydroxy polycyclic aromatic hydrocarbons in urine coupled with liquid chromatography-tandem mass spectrometry. The effect of graphene oxide amount, washing solvent, eluting solvent, and its volume on the extraction performance were investigated. The fabricated monoliths gave higher adsorption efficiency and capacity than the neat polymer monolith and commercial C18 sorbent. Under the optimum conditions, the developed method provided the detection limits (S/N = 3) of 0.02-0.1 ng/mL and the linear ranges of 0.1-1500 ng/mL for six analytes in urine sample. The recoveries at three spiked levels ranged from 77.5 to 97.1%. Besides, the intra column-to-column (n = 3) and inter batch-to-batch (n = 3) precisions were ≤ 9.8%. The developed method was successfully applied for the determination of hydroxy polycyclic aromatic hydrocarbons in urine samples of coke oven workers.
Collapse
Affiliation(s)
- Zi-Ling Li
- School of Public Health, North China University of Science and Technology, Tangshan, P. R. China
| | - Na Li
- School of Public Health, North China University of Science and Technology, Tangshan, P. R. China
| | - Li Du
- School of Public Health, North China University of Science and Technology, Tangshan, P. R. China
| | - Ya-Hui Wang
- School of Public Health, North China University of Science and Technology, Tangshan, P. R. China
| | - Bo Fang
- School of Public Health, North China University of Science and Technology, Tangshan, P. R. China
| | - Man-Man Wang
- School of Public Health, North China University of Science and Technology, Tangshan, P. R. China
| | - Qian Wang
- School of Public Health, North China University of Science and Technology, Tangshan, P. R. China
| |
Collapse
|
29
|
Analysis of endocannabinoids in plasma samples by biocompatible solid-phase microextraction devices coupled to mass spectrometry. Anal Chim Acta 2019; 1091:135-145. [PMID: 31679567 DOI: 10.1016/j.aca.2019.09.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Revised: 08/30/2019] [Accepted: 09/01/2019] [Indexed: 11/23/2022]
Abstract
Anandamide (AEA) and 2-arachidonoyl glycerol (2-AG) represent two of the most important endocannabinoids (ECs) investigated in neurobiology as therapeutic targets for several mental disorders. However, the determination of these ECs in biological matrices remains a challenging task because of the low concentrations, low stability and high protein-bound (LogP ∼ 6). This work describes innovative analytical methods based on biocompatible SPME (Bio-SPME), SPME-UHPLC-MS/MS and Bio-SPME-Nano-ESI-MS/MS, to determine AEA and 2-AG in human plasma samples. The direct coupling of Bio-SPME with nano-ESI-MS/MS can be considered an alternative tool for faster analysis. Different Bio-SPME fibers based on silica and polymeric coating (i.e. C18, C30, and HLB) were evaluated. Different desorption solvents based on combinations of methanol, acetonitrile, and isopropanol were also evaluated for efficient elution with minimum carry-over. Given the high protein binding analytes and the fact that SPME extracts the free-concentration of the analytes, the plasma samples were modified with additives such as guanidine hydrochloride (Gu-HCl), trifluoroacetic acid, and acetonitrile. This study was carried out by experimental design to achieve complete protein denaturation and the release of target analytes. The maximum extraction efficiency was obtained under the following conditions: HLB coated fibers (10 mm length, 20 μm coating thickness), matrix modified (300 μL of plasma) with 50 μL of Gu-HCL 1 mol L-1, 75 μL of ACN and 75 μL of water, and desorption with methanol/isopropanol solution (50:50, v/v). Both methods were validated based on current international guidelines and can be applied for monitoring of concentrations of endocannabinoids in plasma samples. SPME-UHPLC-MS/MS method presented lower LOQ values than SPME-nanoESI-MS/MS. The additional separation (chromatographic column) favored the detectability of LC-MS/MS method. However, the SPME-nano-ESI-MS/MS decrease the total analysis time, due to significant reductions in desorption and detection times.
Collapse
|
30
|
So PK, Yang BC, Li W, Wu L, Hu B. Simple Fabrication of Solid-Phase Microextraction with Surface-Coated Aluminum Foil for Enhanced Detection of Analytes in Biological and Clinical Samples by Mass Spectrometry. Anal Chem 2019; 91:9430-9434. [DOI: 10.1021/acs.analchem.9b02428] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Pui-Kin So
- University Research Facility in Life Sciences, The Hong Kong Polytechnic University, Hung Hom, Hong Kong, China
| | - Bi-Cheng Yang
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang 330006, China
| | - Wen Li
- Institute of Laboratory Animal Science, Jinan University, Guangzhou 510632, China
| | - Lin Wu
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Bin Hu
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| |
Collapse
|
31
|
Nian Q, Wang X, Wang M, Zuo G. A hybrid material composed of graphitic carbon nitride and magnetite (Fe3O4) for magnetic solid-phase extraction of trace levels of hydroxylated polycyclic aromatic hydrocarbons. Mikrochim Acta 2019; 186:497. [DOI: 10.1007/s00604-019-3607-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Accepted: 06/13/2019] [Indexed: 12/18/2022]
|
32
|
Determination of Ten Kinds of Monohydroxylated Polycyclic Aromatic Hydrocarbons in Human Urine by Supported Liquid Extraction Followed by Liquid Chromatography-Tandem Mass Spectrometry. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1016/s1872-2040(19)61165-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
33
|
Santos PM, del Nogal Sánchez M, Pavón JLP, Cordero BM. Determination of polycyclic aromatic hydrocarbons in human biological samples: A critical review. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.02.010] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
34
|
|
35
|
A critical outlook on recent developments and applications of matrix compatible coatings for solid phase microextraction. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.12.019] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
36
|
Metal azolate framework-66-coated fiber for headspace solid-phase microextraction of polycyclic aromatic hydrocarbons. J Chromatogr A 2019; 1584:57-63. [DOI: 10.1016/j.chroma.2018.11.043] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2018] [Revised: 11/15/2018] [Accepted: 11/20/2018] [Indexed: 12/20/2022]
|
37
|
Wu J, Sun J, Cheng H, Liu J, Wang Y. Analysis of polycyclic aromatic hydrocarbons by capillary electrochromatography by using capillary columns packed with polycyclic-aromatic-hydrocarbon-specific particles. SEPARATION SCIENCE PLUS 2018. [DOI: 10.1002/sscp.201800063] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Jiabei Wu
- College of Material Chemistry and Chemical Engineering; Hangzhou Normal University; Hangzhou China
| | - Jiannan Sun
- College of Material Chemistry and Chemical Engineering; Hangzhou Normal University; Hangzhou China
| | - Heyong Cheng
- Qianjiang College; Hangzhou Normal University; Hangzhou China
- College of Material Chemistry and Chemical Engineering; Hangzhou Normal University; Hangzhou China
| | - Jinhua Liu
- Qianjiang College; Hangzhou Normal University; Hangzhou China
| | - Yuanchao Wang
- College of Material Chemistry and Chemical Engineering; Hangzhou Normal University; Hangzhou China
| |
Collapse
|
38
|
Martín Santos P, del Nogal Sánchez M, Pérez Pavón JL, Moreno Cordero B. Quantitative and qualitative analysis of polycyclic aromatic hydrocarbons in urine samples using a non-separative method based on mass spectrometry. Talanta 2018; 181:373-379. [DOI: 10.1016/j.talanta.2018.01.032] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 01/11/2018] [Accepted: 01/12/2018] [Indexed: 12/21/2022]
|
39
|
Yang BC, Wan XD, Yang X, Li YJ, Zhang ZY, Wan XJ, Luo Y, Deng W, Wang F, Huang OP. Rapid determination of carbendazim in complex matrices by electrospray ionization mass spectrometry with syringe filter needle. JOURNAL OF MASS SPECTROMETRY : JMS 2018; 53:234-239. [PMID: 29314422 DOI: 10.1002/jms.4057] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2017] [Revised: 11/23/2017] [Accepted: 12/18/2017] [Indexed: 06/07/2023]
Abstract
The determination of pesticide residues is an indispensable task in controlling food safety and environment protection. Carbendazim is one of the extensive uses of pesticides in the agricultural industry. In this study, a simple method utilizing syringe filter has been applied as electrospray ionization emitter for mass spectrometric identification and quantification of carbendazim in complex matrices including soil, natural water, and fruit juice samples, which contain many insoluble materials. With online syringe filter of the complex samples, most of insoluble materials such as soil were excluded in spray ionization process due to the filter effect, and analytes were subsequently sprayed out from syringe needle for mass spectrometric detection. The pore sizes of filters and diameters of syringe needles also were investigated. The analytical performances, including the linear range (1-200 ng·mL-1 ), limit of detection (0.2-0.6 ng·mL-1 , S/N > 3), limit of quantitation (3.5-8.6 ng·mL-1 , S/N > 10), reproducibility (6.4%-12.5%, n = 6), and recoveries (72.1%-91.0%, n = 6) were well acceptable for direct analysis of raw samples. Matrix effect for detection of carbendazim in soil samples also was experimentally investigated. This study demonstrated that syringe filter needle coupled with electrospray ionization mass spectrometry is a simple, efficient, and sensitive method for detection of pesticide residues in water, soil, and fruit juice for risk assessment.
Collapse
Affiliation(s)
- Bi-Cheng Yang
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Xi-di Wan
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Xiao Yang
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Yun-Jun Li
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Zi-Yu Zhang
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Xiao-Ju Wan
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Yong Luo
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Wei Deng
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Feng Wang
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| | - Ou-Ping Huang
- Jiangxi Provincial Maternal and Child Health Hospital, Nanchang, Jiangxi, 330006, China
| |
Collapse
|
40
|
Pacheco-Fernández I, Pino V, Lorenzo-Morales J, Ayala JH, Afonso AM. Salt-induced ionic liquid-based microextraction using a low cytotoxic guanidinium ionic liquid and liquid chromatography with fluorescence detection to determine monohydroxylated polycyclic aromatic hydrocarbons in urine. Anal Bioanal Chem 2018; 410:4701-4713. [DOI: 10.1007/s00216-018-0946-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 01/29/2018] [Accepted: 02/05/2018] [Indexed: 02/06/2023]
|
41
|
Reyes-Garcés N, Gionfriddo E, Gómez-Ríos GA, Alam MN, Boyacı E, Bojko B, Singh V, Grandy J, Pawliszyn J. Advances in Solid Phase Microextraction and Perspective on Future Directions. Anal Chem 2017; 90:302-360. [DOI: 10.1021/acs.analchem.7b04502] [Citation(s) in RCA: 402] [Impact Index Per Article: 57.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
| | | | | | - Md. Nazmul Alam
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Ezel Boyacı
- Department of Chemistry, Middle East Technical University, Ankara 06800, Turkey
| | - Barbara Bojko
- Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, 85-067 Bydgoszcz, Poland
| | - Varoon Singh
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Jonathan Grandy
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| |
Collapse
|
42
|
Huang Y, Ma Y, Hu H, Guo P, Miao L, Yang Y, Zhang M. Rapid and sensitive detection of trace malachite green and its metabolite in aquatic products using molecularly imprinted polymer-coated wooden-tip electrospray ionization mass spectrometry. RSC Adv 2017. [DOI: 10.1039/c7ra10094a] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
In this study, a molecularly imprinted polymer-coated wooden-tip (MIPCWT) electrospray ionization mass spectrometry (ESI-MS) method was developed for rapid and sensitive detection of trace malachite green (MG) and its metabolite in aquatic products.
Collapse
Affiliation(s)
- Yanying Huang
- School of Materials Science and Energy Engineering
- Foshan University
- Foshan 528000
- China
| | - Yanfang Ma
- Guangdong Engineering and Technology Research Center for Ambient Mass Spectrometry
- Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals
- Guangdong Institute of Analysis (China National Analytical Center Guangzhou)
- Guangzhou 510070
- China
| | - Huawen Hu
- School of Materials Science and Energy Engineering
- Foshan University
- Foshan 528000
- China
| | - Pengran Guo
- Guangdong Engineering and Technology Research Center for Ambient Mass Spectrometry
- Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals
- Guangdong Institute of Analysis (China National Analytical Center Guangzhou)
- Guangzhou 510070
- China
| | - Lei Miao
- School of Materials Science and Energy Engineering
- Foshan University
- Foshan 528000
- China
| | - Yunyun Yang
- Guangdong Engineering and Technology Research Center for Ambient Mass Spectrometry
- Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals
- Guangdong Institute of Analysis (China National Analytical Center Guangzhou)
- Guangzhou 510070
- China
| | - Min Zhang
- School of Materials Science and Energy Engineering
- Foshan University
- Foshan 528000
- China
| |
Collapse
|