1
|
Temel ER, Eroğlu AE, Salih B, Boyaci E. Novel electrospun-based extractive probes for rapid determination of clinically important compounds in human plasma. Anal Chim Acta 2024; 1312:342750. [PMID: 38834264 DOI: 10.1016/j.aca.2024.342750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 04/28/2024] [Accepted: 05/20/2024] [Indexed: 06/06/2024]
Abstract
BACKGROUND Coated blade spray (CBS) represents an innovative approach that utilizes solid-phase microextraction principles for sampling and sample preparation. When combined with ambient mass spectrometry (MS), it can also serve as an electrospray ionization source. Therefore, it became a promising tool in analytical applications as it can significantly reduce the analysis time. However, the current CBS coatings are based on the immobilization of extractive particles in bulk polymeric glue, which constrains the diffusion of the analytes to reach the extractive phase; therefore, the full reward of the system cannot be taken at pre-equilibrium. This has sparked the notion of developing new CBS probes that exhibit enhanced kinetics. RESULTS With this aim, to generate a new extractive phase with improved extraction kinetics, poly(divinylbenzene) (PDVB) nanoparticles were synthesized by mini-emulsion polymerization and then immobilized into sub-micrometer (in diameter) sized polyacrylonitrile fibers which were obtained by electrospinning method. Following the optimization and characterization studies, the electrospun-coated blades were used to determine cholesterol, testosterone, and progesterone in plasma spots using the CBS-MS approach. For testosterone and progesterone, 10 ng mL-1 limits of quantification could be obtained, which was 200 ng mL-1 for cholesterol in spot-sized samples without including any pre-treatment steps to samples prior to extraction. SIGNIFICANCE The comparison of the initial kinetics for dip-coated and electrospun-coated CBS probes proved that the electrospinning process could enhance the extraction kinetics; therefore, it can be used for more sensitive analyses. The total analysis time with this method, from sample preparation to instrumental analysis, takes only 7 min, which suggests that the new probes are promising for fast diagnostic applications.
Collapse
Affiliation(s)
- Ezgi Rana Temel
- Department of Chemistry, Middle East Technical University, Ankara, 06800, Turkiye
| | - Ahmet E Eroğlu
- Department of Chemistry, İzmir Institute of Technology, Urla, 35430, İzmir, Turkiye
| | - Bekir Salih
- Department of Chemistry, Hacettepe University, Ankara, 06800, Turkiye
| | - Ezel Boyaci
- Department of Chemistry, Middle East Technical University, Ankara, 06800, Turkiye.
| |
Collapse
|
2
|
Stryjak I, Warmuzińska N, Łuczykowski K, Jaroch K, Urbanellis P, Selzner M, Bojko B. Metabolomic and lipidomic landscape of porcine kidney associated with kidney perfusion in heart beating donors and donors after cardiac death. Transl Res 2024; 267:79-90. [PMID: 38052298 DOI: 10.1016/j.trsl.2023.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 10/23/2023] [Accepted: 12/01/2023] [Indexed: 12/07/2023]
Abstract
Transplant centers are currently facing a lack of tools to ensure adequate evaluation of the quality of the available organs, as well as a significant shortage of kidney donors. Therefore, efforts are being made to facilitate the effective use of available organs and expand the donor pool, particularly with expanded criteria donors. Fulfilling a need, we aim to present an innovative analytical method based on solid-phase microextraction (SPME) - chemical biopsy. In order to track changes affecting the organ throughout the entire transplant procedure, porcine kidneys were subjected to multiple samplings at various time points. The application of small-diameter SPME probes assured the minimal invasiveness of the procedure. Porcine model kidney autotransplantation was executed for the purpose of simulating two types of donor scenarios: donors with a beating heart (HBD) and donors after cardiac death (DCD). All renal grafts were exposed to continuous normothermic ex vivo perfusion. Following metabolomic and lipidomic profiling using high-performance liquid chromatography coupled to a mass spectrometer, we observed differences in the profiles of HBD and DCD kidneys. The alterations were predominantly related to energy and glucose metabolism, and differences in the levels of essential amino acids, purine nucleosides, lysophosphocholines, phosphoethanolamines, and triacylglycerols were noticed. Our results indicate the potential of implementing chemical biopsy in the evaluation of graft quality and monitoring of renal function during perfusion.
Collapse
Affiliation(s)
- Iga Stryjak
- Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland
| | - Natalia Warmuzińska
- Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland
| | - Kamil Łuczykowski
- Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland
| | - Karol Jaroch
- Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland
| | - Peter Urbanellis
- Ajmera Transplant Center, Department of Surgery, Toronto General Hospital, University Health Network, Toronto, ON, Canada
| | - Markus Selzner
- Ajmera Transplant Center, Department of Surgery, Toronto General Hospital, University Health Network, Toronto, ON, Canada; Department of Medicine, Toronto General Hospital, Toronto, ON, Canada
| | - Barbara Bojko
- Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland.
| |
Collapse
|
3
|
Henderson A, Heaney LM, Rankin-Turner S. Ambient ionisation mass spectrometry for drug and toxin analysis: A review of the recent literature. Drug Test Anal 2024. [PMID: 38326879 DOI: 10.1002/dta.3644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 11/17/2023] [Accepted: 12/28/2023] [Indexed: 02/09/2024]
Abstract
Ambient ionisation mass spectrometry (AIMS) is a form of mass spectrometry whereby analyte ionisation occurs outside of a vacuum source under ambient conditions. This enables the direct analysis of samples in their native state, with little or no sample preparation and without chromatographic separation. The removal of these steps facilitates a much faster analytical process, enabling the direct analysis of samples within minutes if not seconds. Consequently, AIMS has gained rapid popularity across a diverse range of applications, in particular the analysis of drugs and toxins. Numerous fields rely upon mass spectrometry for the detection and identification of drugs, including clinical diagnostics, forensic chemistry, and food safety. However, all of these fields are hindered by the time-consuming and laboratory-confined nature of traditional techniques. As such, the potential for AIMS to resolve these challenges has resulted in a growing interest in ambient ionisation for drug and toxin analysis. Since the early 2000s, forensic science, diagnostic testing, anti-doping, pharmaceuticals, environmental analysis and food safety have all seen a marked increase in AIMS applications, foreshadowing a new future for drug testing. In this review, some of the most promising AIMS techniques for drug analysis will be discussed, alongside different applications of AIMS published over a 5-year period, to provide a summary of the recent research activity for ambient ionisation for drug and toxin analysis.
Collapse
Affiliation(s)
- Alisha Henderson
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Liam M Heaney
- School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
| | - Stephanie Rankin-Turner
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public Health, Johns Hopkins University, Baltimore, Maryland, USA
| |
Collapse
|
4
|
Fang Z, Zhang H, Guo J, Guo J. Overview of therapeutic drug monitoring and clinical practice. Talanta 2024; 266:124996. [PMID: 37562225 DOI: 10.1016/j.talanta.2023.124996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 06/29/2023] [Accepted: 07/25/2023] [Indexed: 08/12/2023]
Abstract
With the rapid development of clinical pharmacy in China, therapeutic drug monitoring (TDM) has become an essential tool for guiding rational clinical drug use and is widely concerned. TDM is a tool that combines pharmacokinetic and pharmacodynamic knowledge to optimize personalized drug therapy, which can improve treatment outcomes, reduce drug-drug toxicity, and avoid the risk of developing drug resistance. To effectively implement TDM, accurate and sophisticated analytical methods are required. By researching the literature published in recent years, we summarize the types of commonly monitored drugs, therapeutic windows, and clinical assays and track the trends and hot spots of therapeutic drug monitoring. The purpose is to provide guidelines for clinical blood drug concentration monitoring, to implement individualized drug delivery programs better, to ensure the rational use of drugs for patients, and to provide a reference for the group to carry out related topics in the future.
Collapse
Affiliation(s)
- Zijun Fang
- University of Southwest Petroleum University, College of Mechanical and Electrical Engineering, Chengdu, China
| | - He Zhang
- University of Southwest Petroleum University, College of Mechanical and Electrical Engineering, Chengdu, China
| | - Jiuchuan Guo
- University of Electronic Science and Technology of China, Chengdu, China.
| | - Jinhong Guo
- School of Sensing Science and Engineering, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
5
|
Dos Santos KC, Dos Reis LR, Rodero CF, Sábio RM, Junior AGT, Gremião MPD, Chorilli M. Bioproperties, Nanostructured System and Analytical and Bioanalytical Methods for Determination of Rapamycin: A Review. Crit Rev Anal Chem 2023:1-9. [PMID: 37990513 DOI: 10.1080/10408347.2020.1839737-test] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2023]
Abstract
The drug rapamycin is a potent inhibitor of the mTOR complex, acting directly in the signaling cascade of this protein complex; interrupting cell proliferation, in addition to being an extremely efficient immunosuppressant. Currently this drug is being used in several types of cancer. Rapamycin has been a target of great interest within nanomedicine involving nanostructured systems for drug delivery aiming to increase the bioactivity and bioavailability of this drug. In addition, there is a constant search for analytical methods to identify and quantify this drug. Numerous high-performance liquid chromatography analytical techniques, mass spectrometry and immunoassay techniques have been employed efficiently in an attempt to develop increasingly sensitive analytical methods. Thus, this review sought to bring together current and relevant scientific works involving rapamycin and; besides analytical methods more used for quantification of this molecule.
Collapse
Affiliation(s)
| | | | - Camila Fernanda Rodero
- School of Pharmaceutical Sciences, São Paulo State University (UNESP), São Paulo, Brazil
| | - Rafael Miguel Sábio
- School of Pharmaceutical Sciences, São Paulo State University (UNESP), São Paulo, Brazil
| | | | | | - Marlus Chorilli
- School of Pharmaceutical Sciences, São Paulo State University (UNESP), São Paulo, Brazil
| |
Collapse
|
6
|
Shi L, Habib A, Bi L, Hong H, Begum R, Wen L. Ambient Ionization Mass Spectrometry: Application and Prospective. Crit Rev Anal Chem 2022:1-50. [PMID: 36206159 DOI: 10.1080/10408347.2022.2124840] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/10/2022]
Abstract
Mass spectrometry (MS) is a formidable analytical tool for the analysis of non-polar to polar compounds individually and/or from mixtures, providing information on the molecular weights and chemical structures of the analytes. During the last more than one-decade, ambient ionization mass spectrometry (AIMS) has developed quickly, producing a wide range of platforms and proving scientific improvements in a variety of domains, from biological imaging to quick quality control. These methods have made it possible to detect target analytes in real time without sample preparation in an open environment, and they can be connected to any MS system with an atmospheric pressure interface. They also have the ability to analyze explosives, illicit drugs, disease diagnostics, drugs in biological samples, adulterants in food and agricultural products, reaction progress, and environmental monitoring. The development of novel ambient ionization techniques, such as probe electrospray ionization, paper spray ionization, and fiber spray ionization, employed even at picolitre to femtolitre solution levels to provide femtogram to attogram levels of the target analytes. The special characteristic of this ambient ion source, which has been extensively used, is the noninvasive property of PESI of examination of biological real samples. The results in the current review supports the idea that AIMS has emerged as a pioneer in MS-based approaches and that methods will continue to be developed along with improvements to existing ones in the near future.
Collapse
Affiliation(s)
- Lulu Shi
- Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, China
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
| | - Ahsan Habib
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
- Department of Chemistry, University of Dhaka, Dhaka, Bangladesh
| | - Lei Bi
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| | - Huanhuan Hong
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| | - Rockshana Begum
- Department of Chemistry, Shahjalal University of Science and Technology, Sylhet, Bangladesh
| | - Luhong Wen
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| |
Collapse
|
7
|
Zhou W, Nazdrajić E, Pawliszyn J. Rapid Screening and Quantitation of Drugs of Abuse by Both Positive and Negative Modes via Coated Blade Spray-Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:1187-1193. [PMID: 35609124 DOI: 10.1021/jasms.2c00040] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Solid-phase microextraction (SPME)-direct mass spectrometry (MS) has proven to be an efficient tool for the rapid screening and quantitation of target compounds at trace levels. However, it is challenging to perform screening using both positive and negative modes in one analytical run without compromising scanning speed and detection sensitivity. To take advantage of the special geometry of a coated blade spray (CBS) blade, which consists of two flat sides coated with the same SPME coating, we developed a CBS-MS method that enables desorption and ionization to be performed in positive ionization mode on one side of a coated blade and negative ionization mode on the other side of the same blade. By simply flipping the blade 180°, MS analysis in both ionization modes on different sides can be completed in 40 s. Combining this approach with an automated Concept 96-blade-based SPME system allowed analysis for one sample in positive and negative modes to be completed in less than 1 min. The workflow was optimized by using a biocompatible polyacrylonitrile as an undercoating layer and a binder of polyacrylonitrile/hydrophilic-lipophilic balance (HLB) particles, which enabled the rapid analysis of 20 drugs of abuse in saliva samples in both positive and negative modes. The proposed method provided low limits of quantification (between 0.005 and 10 ng/mL), with calibration linear correlation coefficients ⩾ 0.9925, accuracy between 72% and 126%, and relative precision < 15% for three validation points.
Collapse
Affiliation(s)
- Wei Zhou
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
8
|
Solid-phase microextraction: a fit-for-purpose technique in biomedical analysis. Anal Bioanal Chem 2022; 414:7005-7013. [PMID: 35606454 PMCID: PMC9126758 DOI: 10.1007/s00216-022-04138-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 05/02/2022] [Accepted: 05/17/2022] [Indexed: 12/13/2022]
Abstract
Solid-phase microextraction (SPME) possesses unique features that allow it to be used in analyses that would not be possible with traditional sample-preparation methods. The simplicity of SPME protocols and extraction devices makes it a uniform platform for analyzing biological samples, either via the headspace or in direct immersion mode. Furthermore, flexible probe design enables SPME to be applied to target objects of different sizes, offering analysis on a scale ranging “from single cell to living organs”. SPME microfibers are minimally invasive, which enables them to be applied for the spatial and temporal monitoring of target analytes or to assess changes in the entire metabolome or lipidome. Furthermore, SPME permits the capture of the elusive portion of the metabolome, thus complementing exhaustive methods that are biased towards highly abundant and stable species. Significantly, SPME can be interfaced with analytical instrumentation to create a rapid diagnostic tool. However, despite these advantages, SPME has some limitations that must be well-understood and addressed. This paper presents examples of up-to-date applications of SPME, challenges related to particular studies, and future perspectives regarding the application of SPME in biomedical analysis.
Collapse
|
9
|
Coated Blade Spray-Mass Spectrometry as a New Approach for the Rapid Characterization of Brain Tumors. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27072251. [PMID: 35408649 PMCID: PMC9000701 DOI: 10.3390/molecules27072251] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 03/25/2022] [Accepted: 03/28/2022] [Indexed: 11/16/2022]
Abstract
Brain tumors are neoplasms with one of the highest mortality rates. Therefore, the availability of methods that allow for the quick and effective diagnosis of brain tumors and selection of appropriate treatments is of critical importance for patient outcomes. In this study, coated blade spray-mass spectrometry (CBS-MS), which combines the features of microextraction and fast ionization methods, was applied for the analysis of brain tumors. In this approach, a sword-shaped probe is coated with a sorptive material to enable the extraction of analytes from biological samples. The analytes are then desorbed using only a few microliters of solvent, followed by the insertion of the CBS device into the interface on the mass spectrometer source. The results of this proof-of-concept experiment confirmed that CBS coupled to high-resolution mass spectrometry (HRMS) enables the rapid differentiation of two histologically different lesions: meningiomas and gliomas. Moreover, quantitative CBS-HRMS/MS analysis of carnitine, the endogenous compound, previously identified as a discriminating metabolite, showed good reproducibility with the variation below 10% when using a standard addition calibration strategy and deuterated internal standards for correction. The resultant data show that the proposed CBS-MS technique can be useful for on-site qualitative and quantitative assessments of brain tumor metabolite profiles.
Collapse
|
10
|
Mohamed HM. Solventless Microextration Techniques for Pharmaceutical Analysis: The Greener Solution. Front Chem 2022; 9:785830. [PMID: 35096766 PMCID: PMC8792605 DOI: 10.3389/fchem.2021.785830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Accepted: 12/13/2021] [Indexed: 11/13/2022] Open
Abstract
Extensive efforts have been made in the last decades to simplify the holistic sample preparation process. The idea of maximizing the extraction efficiency along with the reduction of extraction time, minimization/elimination of hazardous solvents, and miniaturization of the extraction device, eliminating sample pre- and posttreatment steps and reducing the sample volume requirement is always the goal for an analyst as it ensures the method’s congruency with the green analytical chemistry (GAC) principles and steps toward sustainability. In this context, the microextraction techniques such as solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE), microextraction by packed sorbent (MEPS), fabric phase sorptive extraction (FPSE), in-tube extraction dynamic headspace (ITEX-DHS), and PAL SPME Arrow are being very active areas of research. To help transition into wider applications, the new solventless microextraction techniques have to be commercialized, automated, and validated, and their operating principles to be anchored to theory. In this work, the benefits and drawbacks of the advanced microextraction techniques will be discussed and compared, together with their applicability to the analysis of pharmaceuticals in different matrices.
Collapse
|
11
|
Azizi A, Shahhoseini F, Langille EA, Akhoondi R, Bottaro CS. Micro-gel thin film molecularly imprinted polymer coating for extraction of organophosphorus pesticides from water and beverage samples. Anal Chim Acta 2021; 1187:339135. [PMID: 34753563 DOI: 10.1016/j.aca.2021.339135] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 09/05/2021] [Accepted: 09/15/2021] [Indexed: 11/17/2022]
Abstract
Molecularly imprinted polymers (MIPs) have become an important class of materials for selective and efficient adsorption of target analytes. Despite versatility of MIPs for fabrication in numerous formats, these materials have been primarily reported as solid phase extraction packing materials. An effective thin film MIP prepared on stainless steel substrate is reported here for high throughput enrichment of organophosphorus pesticides (OPPs) from water and beverage samples followed by liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis. The key factors controlling performance as well as best practices for optimized fabrication of thin film MIPs are presented. A pseudo-phase diagram is introduced to evaluate and predict the effect of the ratio of porogen (solvent, 1-octanol) volume to relative crosslinker mass on the desired polymer features (i.e., porosity, surface area, capacity, and selectivity). At low porogen ratios, a macroporous polymer with insignificant selectivity is formed, whereas at high porogen ratios a micro-gel polymer with superior selectivity towards targets is obtained. The porosity and morphology determined with nitrogen adsorption and scanning electron microscopy were attributed to specific regions in the pseudo-phase diagram. Other factors influencing selectivity and stability of the polymer, such as type of the template and its ratios with monomer (methacrylic acid) and crosslinker (ethylene glycol dimethacrylate) were optimized. The prepared thin film MIPs were characterized using adsorption isotherms and adsorption kinetics, and evaluated for matrix effects (high humic acid content) and cross-reactivity in presence of other pesticides and pharmaceuticals. The optimized method provided limits of quantitation (LOQs) ranged from 0.002 to 0.02 ng mL-1 in water and from 0.095 to 0.48 ng g-1 in apple juice. Regarding inter-device variability (CV∼10% without normalization), excellent linearity (R2 > 0.99), satisfactory accuracies (90-110%) and precisions (<15%) were obtained.
Collapse
Affiliation(s)
- Ali Azizi
- Department of Chemistry, Memorial University of Newfoundland, Canada
| | | | - Evan A Langille
- Department of Chemistry, Memorial University of Newfoundland, Canada
| | - Reza Akhoondi
- Department of Chemistry, Memorial University of Newfoundland, Canada
| | | |
Collapse
|
12
|
Seyfinejad B, Jouyban A. Overview of therapeutic drug monitoring of immunosuppressive drugs: Analytical and clinical practices. J Pharm Biomed Anal 2021; 205:114315. [PMID: 34399192 DOI: 10.1016/j.jpba.2021.114315] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 07/16/2021] [Accepted: 08/05/2021] [Indexed: 01/04/2023]
Abstract
Immunosuppressant drugs (ISDs) play a key role in short-term patient survival together with very low acute allograft rejection rates in transplant recipients. Due to the narrow therapeutic index and large inter-patient pharmacokinetic variability of ISDs, therapeutic drug monitoring (TDM) is needed to dose adjustment for each patient (personalized medicine approach) to avoid treatment failure or side effects of the therapy. To achieve this, TDM needs to be done effectively. However, it would not be possible without the proper clinical practice and analytical tools. The purpose of this review is to provide a guide to establish reliable TDM, followed by a critical overview of the current analytical methods and clinical practices for the TDM of ISDs, and to discuss some of the main practical aspects of the TDM.
Collapse
Affiliation(s)
- Behrouz Seyfinejad
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran; Student Research Committee, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Abolghasem Jouyban
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran; Faculty of Pharmacy, Near East University, PO BOX: 99138 Nicosia, North Cyprus, Mersin 10, Turkey.
| |
Collapse
|
13
|
Taddeo A, Prim D, Bojescu ED, Segura JM, Pfeifer ME. Point-of-Care Therapeutic Drug Monitoring for Precision Dosing of Immunosuppressive Drugs. J Appl Lab Med 2021; 5:738-761. [PMID: 32533157 DOI: 10.1093/jalm/jfaa067] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Accepted: 04/03/2020] [Indexed: 01/15/2023]
Abstract
BACKGROUND Immunosuppressive drugs (ISD) are an essential tool in the treatment of transplant rejection and immune-mediated diseases. Therapeutic drug monitoring (TDM) for determination of ISD concentrations in biological samples is an important instrument for dose personalization for improving efficacy while reducing side effects. While currently ISD concentration measurements are performed at specialized, centralized facilities, making the process complex and laborious for the patient, various innovative technical solutions have recently been proposed for bringing TDM to the point-of-care (POC). CONTENT In this review, we evaluate current ISD-TDM and its value, limitations, and proposed implementations. Then, we discuss the potential of POC-TDM in the era of personalized medicine, and provide an updated review on the unmet needs and available technological solutions for the development of POC-TDM devices for ISD monitoring. Finally, we provide concrete suggestions for the generation of a meaningful and more patient-centric process for ISD monitoring. SUMMARY POC-based ISD monitoring may improve clinical care by reducing turnaround time, by enabling more frequent measurements in order to obtain meaningful pharmacokinetic data (i.e., area under the curve) faster reaction in case of problems and by increasing patient convenience and compliance. The analysis of the ISD-TDM field prompts the evolution of POC testing toward the development of fully integrated platforms able to support clinical decision-making. We identify 4 major areas requiring careful combined implementation: patient usability, data meaningfulness, clinicians' acceptance, and cost-effectiveness.
Collapse
Affiliation(s)
- Adriano Taddeo
- Institute of Life Technologies - School of Engineering, HES-SO//University of Applied Sciences, Western Switzerland, Sion, Switzerland
| | - Denis Prim
- Institute of Life Technologies - School of Engineering, HES-SO//University of Applied Sciences, Western Switzerland, Sion, Switzerland
| | - Elena-Diana Bojescu
- Institute of Life Technologies - School of Engineering, HES-SO//University of Applied Sciences, Western Switzerland, Sion, Switzerland
| | - Jean-Manuel Segura
- Institute of Life Technologies - School of Engineering, HES-SO//University of Applied Sciences, Western Switzerland, Sion, Switzerland
| | - Marc E Pfeifer
- Institute of Life Technologies - School of Engineering, HES-SO//University of Applied Sciences, Western Switzerland, Sion, Switzerland
| |
Collapse
|
14
|
Shahhoseini F, Langille EA, Azizi A, Bottaro CS. Thin film molecularly imprinted polymer (TF-MIP), a selective and single-use extraction device for high-throughput analysis of biological samples. Analyst 2021; 146:3157-3168. [PMID: 33999057 DOI: 10.1039/d0an02228d] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Enhancing selectivity, reducing matrix effects and increasing analytical throughput have been the main objectives in the development of biological sample preparation techniques. A thin film molecularly imprinted polymer (MIP) is employed for extraction and analysis of tricyclic antidepressants (TCAs) as a model class of compounds in human plasma for the first time to reach the abovementioned goals. The thin film MIPs prepared on a metal substrate can be used directly for extraction from biological matrices with no sample manipulation steps and no pre-conditioning. This method was validated with good linearity (R2 > 0.99 in 1.0-500.0 ng mL-1 range), excellent accuracy (90% -110%) and precision (RSD % value less than 15%) in pooled human plasma samples (N = 3). The limits of quantitation (LOQ) for TCAs in plasma samples were between 1.0-5.0 ng mL-1 which are lower than the therapeutic ranges of these drugs. Kinetic and isotherm studies showed the superior performance of MIP sorbent compared to a non-imprinted polymer (NIP) sorbent in extracting TCAs from a bovine serum albumin (BSA) solution. The optimized and validated method for pooled human plasma was utilized for monitoring the concentration of TCAs in three patient samples who had been prescribed TCAs. These selective single-use thin film extraction devices are promising for efficient and fast procedures for analyzing biological samples.
Collapse
Affiliation(s)
- Fereshteh Shahhoseini
- Department of Chemistry, Memorial University of Newfoundland, St. John's, A1B 3X7, Canada.
| | | | | | | |
Collapse
|
15
|
Mikhail IE, Tehranirokh M, Gooley AA, Guijt RM, Breadmore MC. Hyphenated sample preparation-electrospray and nano-electrospray ionization mass spectrometry for biofluid analysis. J Chromatogr A 2021; 1646:462086. [PMID: 33892255 DOI: 10.1016/j.chroma.2021.462086] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 03/18/2021] [Accepted: 03/19/2021] [Indexed: 10/21/2022]
Abstract
Stand-alone electrospray ionization mass spectrometry (ESI-MS) has been advancing through enhancements in throughput, selectivity and sensitivity of mass spectrometers. Unlike traditional MS techniques which usually require extensive offline sample preparation and chromatographic separation, many sample preparation techniques are now directly coupled with stand-alone MS to enable outstanding throughput for bioanalysis. In this review, we summarize the different sample clean-up and/or analyte enrichment strategies that can be directly coupled with ESI-MS and nano-ESI-MS for the analysis of biological fluids. The overview covers the hyphenation of different sample preparation techniques including solid phase extraction (SPE), solid phase micro-extraction (SPME), slug flow micro-extraction/nano-extraction (SFME/SFNE), liquid extraction surface analysis (LESA), extraction electrospray, extraction using digital microfluidics (DMF), and electrokinetic extraction (EkE) with ESI-MS and nano-ESI-MS.
Collapse
Affiliation(s)
- Ibraam E Mikhail
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia; Department of Analytical Chemistry, Faculty of Pharmacy, Mansoura University, 35516, Egypt
| | - Masoomeh Tehranirokh
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), Australia; Trajan Scientific and Medical, Ringwood, VIC, 3134, Australia
| | - Andrew A Gooley
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), Australia; Trajan Scientific and Medical, Ringwood, VIC, 3134, Australia
| | - Rosanne M Guijt
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), Australia; Centre for Regional and Rural Futures, Deakin University, Geelong, VIC, 3220, Australia
| | - Michael C Breadmore
- ARC Training Centre for Portable Analytical Separation Technologies (ASTech), Australia; Australian Centre for Research on Separation Science (ACROSS), School of Natural Sciences (Chemistry), University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.
| |
Collapse
|
16
|
Rapid determination of tacrolimus and sirolimus in whole human blood by direct coupling of solid-phase microextraction to mass spectrometry via microfluidic open interface. Anal Chim Acta 2020; 1144:53-60. [PMID: 33453797 DOI: 10.1016/j.aca.2020.11.056] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 11/23/2020] [Accepted: 11/30/2020] [Indexed: 12/29/2022]
Abstract
Immunosuppressive drugs are administered to decrease immune system activity (e.g. of patients undergoing solid organ transplant). Concentrations of immunosuppressive drugs (ISDs) in circulating blood must be closely monitored during the period of immunosuppression therapy due to adverse effects that take place when concentration levels fall outside of the very narrow therapeutic concentration range of these drugs. This study presents the rapid determination of four relevant immunosuppressive drugs (tacrolimus, sirolimus, everolimus, and cyclosporine A) in whole human blood by directly coupling solid-phase microextraction to mass spectrometry via the microfluidic open interface (Bio-SPME-MOI-MS/MS). The BioSPME-MOI-MS/MS method offers ≤ 10% imprecision of in-house prepared quality controls over a 10-day period, ≤ 10% imprecision of ClinCal® Recipe calibrators over a three-day period, and single total turnaround time of ∼ 60 min (4.5 min for high throughput). The limits of quantification were determined to be 0.8 ng mL-1 for tacrolimus, 0.7 ng mL-1 sirolimus, 1.0 ng mL-1 for everolimus, and 0.8 ng mL-1 for cyclosporine. The limits of detection were determined to be 0.3 ng mL-1 for tacrolimus, 0.2 ng mL-1 for sirolimus, 0.3 ng mL-1 for everolimus, and 0.3 ng mL-1 for cyclosporine A. The R2 values for all analytes were above 0.9992 with linear dynamic range from 1.0 mL-1 to 50.0 ng mL-1 for tacrolimus, sirolimus, and everolimus while from 2.5 ng mL-1 to 500.0 ng mL-1 for cyclosporine A. To further evaluate the performance of the present method, 95 residual whole blood samples of tacrolimus and sirolimus from patients undergoing immunosuppression therapy were used to compare the Bio-SPME-MOI-MS/MS method against a clinically validated reference method based on chemiluminescent microparticle immunoassay, showing acceptable results. Our results demonstrated that Bio-SPME-MOI-MS/MS can be considered as a suitable alternative to existing methods for the determination of immunosuppressive drugs in whole blood providing faster analysis, better selectivity and sensitivity, and a wider dynamic range than current existing approaches.
Collapse
|
17
|
Dos Santos KC, Dos Reis LR, Rodero CF, Sábio RM, Junior AGT, Gremião MPD, Chorilli M. Bioproperties, Nanostructured System and Analytical and Bioanalytical Methods for Determination of Rapamycin: A Review. Crit Rev Anal Chem 2020; 52:897-905. [PMID: 33138632 DOI: 10.1080/10408347.2020.1839737] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The drug rapamycin is a potent inhibitor of the mTOR complex, acting directly in the signaling cascade of this protein complex; interrupting cell proliferation, in addition to being an extremely efficient immunosuppressant. Currently this drug is being used in several types of cancer. Rapamycin has been a target of great interest within nanomedicine involving nanostructured systems for drug delivery aiming to increase the bioactivity and bioavailability of this drug. In addition, there is a constant search for analytical methods to identify and quantify this drug. Numerous high-performance liquid chromatography analytical techniques, mass spectrometry and immunoassay techniques have been employed efficiently in an attempt to develop increasingly sensitive analytical methods. Thus, this review sought to bring together current and relevant scientific works involving rapamycin and; besides analytical methods more used for quantification of this molecule.
Collapse
Affiliation(s)
| | | | - Camila Fernanda Rodero
- School of Pharmaceutical Sciences, São Paulo State University (UNESP), São Paulo, Brazil
| | - Rafael Miguel Sábio
- School of Pharmaceutical Sciences, São Paulo State University (UNESP), São Paulo, Brazil
| | | | | | - Marlus Chorilli
- School of Pharmaceutical Sciences, São Paulo State University (UNESP), São Paulo, Brazil
| |
Collapse
|
18
|
Kasperkiewicz A, Pawliszyn J. Multiresidue pesticide quantitation in multiple fruit matrices via automated coated blade spray and liquid chromatography coupled to triple quadrupole mass spectrometry. Food Chem 2020; 339:127815. [PMID: 32836024 DOI: 10.1016/j.foodchem.2020.127815] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Revised: 08/05/2020] [Accepted: 08/08/2020] [Indexed: 12/20/2022]
Abstract
Application of ambient mass spectrometry techniques to accelerate analysis of pesticides in produce, with technique validation via chromatographic separation, has not been explored extensively. In this work, coated blade spray (CBS) was used to provide freedom of instrumental choice for a multiresidue panel of pesticides in apple, blueberry, grape, and strawberry through direct-coupling with mass spectrometry (MS) and liquid chromatographic (LC) analyses. For all four matrices, >125 compounds were found to meet European Union guidelines concerning linearity, precision, and accuracy while both CBS-MS/MS and SPME-LC-MS/MS methods achieved limits of quantitation below their minimum regulatory limits. Additionally, results for samples containing residues (n = 57) yielded good agreement between instrumental methods (percent differences < 20% for 73% residues), supporting CBS as a stand-alone technique or complement to LC confirmation of pesticides in fruit matrices.
Collapse
Affiliation(s)
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada.
| |
Collapse
|
19
|
Frey BS, Damon DE, Badu-Tawiah AK. Emerging trends in paper spray mass spectrometry: Microsampling, storage, direct analysis, and applications. MASS SPECTROMETRY REVIEWS 2020; 39:336-370. [PMID: 31491055 PMCID: PMC7875099 DOI: 10.1002/mas.21601] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Accepted: 07/22/2019] [Indexed: 05/20/2023]
Abstract
Recent advancements in the sensitivity of chemical instrumentation have led to increased interest in the use of microsamples for translational and biomedical research. Paper substrates are by far the most widely used media for biofluid collection, and mass spectrometry is the preferred method of analysis of the resultant dried blood spot (DBS) samples. Although there have been a variety of review papers published on DBS, there has been no attempt to unify the century old DBS methodology with modern applications utilizing modified paper and paper-based microfluidics for sampling, storage, processing, and analysis. This critical review will discuss how mass spectrometry has expanded the utility of paper substrates from sample collection and storage, to direct complex mixture analysis to on-surface reaction monitoring.
Collapse
Affiliation(s)
| | | | - Abraham K. Badu-Tawiah
- Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio 43210
| |
Collapse
|
20
|
Marrubini G, Dugheri S, Cappelli G, Arcangeli G, Mucci N, Appelblad P, Melzi C, Speltini A. Experimental designs for solid-phase microextraction method development in bioanalysis: A review. Anal Chim Acta 2020; 1119:77-100. [DOI: 10.1016/j.aca.2020.04.012] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 04/03/2020] [Accepted: 04/04/2020] [Indexed: 12/28/2022]
|
21
|
Shiea J, Bhat SM, Su H, Kumar V, Lee CW, Wang CH. Rapid quantification of acetaminophen in plasma using solid-phase microextraction coupled with thermal desorption electrospray ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34 Suppl 1:e8564. [PMID: 31490602 DOI: 10.1002/rcm.8564] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Revised: 08/11/2019] [Accepted: 08/21/2019] [Indexed: 06/10/2023]
Abstract
RATIONALE Solid-phase microextraction coupled with thermal desorption electrospray ionization tandem mass spectrometry (SPME-TD-ESI-MS/MS) is proposed as a novel method for the rapid quantification of acetaminophen in plasma samples from a pharmacokinetics (PK) study. METHODS Traces of acetaminophen were concentrated on commercial fused-silica fibers coated with a polar polyacrylate (PA) polymer using direct immersion SPME. No agitation, heating, addition of salt, or adjustment of the pH of the sample solution was applied during the extraction. Any acetaminophen absorbed on the SPME fibers was subsequently desorbed and detected by TD-ESI-MS/MS. RESULTS Parameters of the absorption, sensitivity, reproducibility, and linearity for the SPME-TD-ESI-MS/MS method were evaluated. The time required to complete a TD-ESI-MS/MS analysis was less than 30 seconds. Matrix-matching calibration was performed to calculate the concentration of acetaminophen in the sample. A linear calibration curve with a concentration range of 100-10,000 ng/mL was constructed to calculate the quantity of acetaminophen. The SPME-TD-ESI-MS quantification results for acetaminophen in plasma were in good agreement with those obtained by the conventional LC/MS/MS method. CONCLUSIONS With the proposed method, a 10-min SPME time was enough to achieve the lower limit of quantitation (i.e. 100 ng/mL) and for a complete PK profiling of acetaminophen. A shorter extraction time could be achieved by applying agitation, heating, adding salt, or adjusting the pH of the sample solution to enhance analyte absorption efficiency. The time required to detect acetaminophen on the SPME fiber was less than 30 s, allowing the rapid quantification of acetaminophen in plasma with good accuracy.
Collapse
Affiliation(s)
- Jentaie Shiea
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
- Department of Medical and Applied Chemistry, Kaohsiung Medical University, Kaohsiung, Taiwan
| | | | - Hung Su
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Vinoth Kumar
- Department of Medical and Applied Chemistry, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chi-Wei Lee
- Institute of Medical Science and Technology, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | - Chin-Hsiung Wang
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| |
Collapse
|
22
|
Yee WLS, Drum CL. Increasing Complexity to Simplify Clinical Care: High Resolution Mass Spectrometry as an Enabler of AI Guided Clinical and Therapeutic Monitoring. ADVANCED THERAPEUTICS 2020. [DOI: 10.1002/adtp.201900163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Wei Loong Sherman Yee
- Yong Loo Lin School of MedicineDepartment of MedicineNational University of Singapore Singapore 119077 Singapore
- Cardiovascular Research Institute (CVRI)National University Health System Singapore 119228 Singapore
| | - Chester Lee Drum
- Yong Loo Lin School of MedicineDepartment of MedicineNational University of Singapore Singapore 119077 Singapore
- Cardiovascular Research Institute (CVRI)National University Health System Singapore 119228 Singapore
- Yong Loo Lin School of MedicineDepartment of BiochemistryNational University of Singapore Singapore 119077 Singapore
- The N.1 Institute for Health (N.1)National University of Singapore Singapore 119077 Singapore
| |
Collapse
|
23
|
Khaled A, Gómez-Ríos GA, Pawliszyn J. Optimization of Coated Blade Spray for Rapid Screening and Quantitation of 105 Veterinary Drugs in Biological Tissue Samples. Anal Chem 2020; 92:5937-5943. [PMID: 32192344 DOI: 10.1021/acs.analchem.0c00093] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Rapid and efficient determination of contaminants at trace levels in tissue samples has become an unmet need around the globe. Coated blade spray (CBS) extraction/ionization is a technology capable of performing, with a single device, enrichment of analytes present in complex matrices, as well as the direct interface and introduction of said analytes into the mass spectrometer via electrospray ionization. To facilitate the challenging rapid tissue screening, we describe for the first time the use of a very thin layer of biocompatible polyacrylonitrile as a CBS device undercoating to make metal surface biocompatible. This add-on is meant to protect the portion of the uncoated stainless-steel of the blade that is normally exposed to the matrix, consequently becoming susceptible to adhesion of matrix macromolecules, cells, and fat. In addition, we present for the first time the use of CBS in negative ionization mode for quantitative purposes. The optimized CBS workflow allows for rapid and high-throughput screening and quantitation of 105 veterinary drugs in homogenized bovine tissue in both negative and positive ionization mode in one single run using a single CBS device with analysis times as short as 1 min per sample when 96 extractions are simultaneously conducted. While only two internal standards were used for correction, one per ionization mode, excellent accuracy and precision were achieved, with more than 90% of analytes falling within the 70-120% range of their true concentrations and yielding RSD ≤ 25% at three validation levels. The majority of analytes achieved linear correlation coefficients >0.99, and all 105 analytes were able to meet both Canadian and U.S. regulatory levels.
Collapse
Affiliation(s)
- Abir Khaled
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Germán Augusto Gómez-Ríos
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
24
|
Evaluation of a coated blade spray-tandem mass spectrometry assay as a new tool for the determination of immunosuppressive drugs in whole blood. Anal Bioanal Chem 2020; 412:5067-5076. [DOI: 10.1007/s00216-019-02367-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 12/09/2019] [Accepted: 12/19/2019] [Indexed: 01/07/2023]
|
25
|
Acquaro Junior VR, Rodrigues JP, Moraes LAB. Solid phase microextraction as a powerful alternative for screening of secondary metabolites in actinomycetes. JOURNAL OF MASS SPECTROMETRY : JMS 2019; 54:823-833. [PMID: 31476245 DOI: 10.1002/jms.4434] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Revised: 08/24/2019] [Accepted: 08/26/2019] [Indexed: 06/10/2023]
Abstract
Actinobacteria are one of the most promising producers of medically and industrially relevant secondary metabolites. However, screening of such compounds in actinobacteria growth demands simple, fast, and efficient extraction procedures that enable detection and precise quantification of biologically active compounds. In this regard, solid phase microextraction (SPME) emerges as an ideal extraction technique for screening of secondary metabolites in bacteria culture due to its non-exhaustive, minimally invasive, and non-destructive nature: its integrated sample preparation workflow; balanced coverage feature; metabolism quenching capabilities; and superior cleanup, as well as its versatility in configuration, which enables automation and high throughput applications. The current work provides a comparison of micro-scale and direct immersion SPME (DI-SPME) for screening of secondary metabolites, describes the optimization of the developed DI-SPME method, and introduces the developed technique for mapping of target secondary metabolites as well as its direct coupling to mass spectrometry for such applications. The optimized DI-SPME method provided higher amounts of extracted ions and intensity signals, yielding superior extraction and desorption efficiency as compared with micro-scale extraction. Studied compounds presented stability on the coating for 24 h at room temperature. The DI-SPME mapping approach revealed that lysolipin I and the lienomycin analog are distributed along the center and edges of the colony, respectively. Direct coupling of SPME to MS provided a similar ions profile as SPME-LC-MS while enabling a significant decrease in analysis time, demonstrating its suitability for such applications. DI-SPME is herein presented as an alternative to micro-scale extraction for screening of secondary metabolites in actinobacteria solid medium, as well as a feasible alternative to DESI-IMS for mapping of biologic radial distribution of secondary metabolites and cell life cycle studies. Lastly, the direct coupling of DI-SPME to MS is presented as a fast, powerful technique for high throughput analysis of secondary metabolites in this medium.
Collapse
Affiliation(s)
| | - Júlia Pereira Rodrigues
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, São Paulo, Brazil
| | - Luiz Alberto Beraldo Moraes
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, São Paulo, Brazil
| |
Collapse
|
26
|
Analysis of endocannabinoids in plasma samples by biocompatible solid-phase microextraction devices coupled to mass spectrometry. Anal Chim Acta 2019; 1091:135-145. [PMID: 31679567 DOI: 10.1016/j.aca.2019.09.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Revised: 08/30/2019] [Accepted: 09/01/2019] [Indexed: 11/23/2022]
Abstract
Anandamide (AEA) and 2-arachidonoyl glycerol (2-AG) represent two of the most important endocannabinoids (ECs) investigated in neurobiology as therapeutic targets for several mental disorders. However, the determination of these ECs in biological matrices remains a challenging task because of the low concentrations, low stability and high protein-bound (LogP ∼ 6). This work describes innovative analytical methods based on biocompatible SPME (Bio-SPME), SPME-UHPLC-MS/MS and Bio-SPME-Nano-ESI-MS/MS, to determine AEA and 2-AG in human plasma samples. The direct coupling of Bio-SPME with nano-ESI-MS/MS can be considered an alternative tool for faster analysis. Different Bio-SPME fibers based on silica and polymeric coating (i.e. C18, C30, and HLB) were evaluated. Different desorption solvents based on combinations of methanol, acetonitrile, and isopropanol were also evaluated for efficient elution with minimum carry-over. Given the high protein binding analytes and the fact that SPME extracts the free-concentration of the analytes, the plasma samples were modified with additives such as guanidine hydrochloride (Gu-HCl), trifluoroacetic acid, and acetonitrile. This study was carried out by experimental design to achieve complete protein denaturation and the release of target analytes. The maximum extraction efficiency was obtained under the following conditions: HLB coated fibers (10 mm length, 20 μm coating thickness), matrix modified (300 μL of plasma) with 50 μL of Gu-HCL 1 mol L-1, 75 μL of ACN and 75 μL of water, and desorption with methanol/isopropanol solution (50:50, v/v). Both methods were validated based on current international guidelines and can be applied for monitoring of concentrations of endocannabinoids in plasma samples. SPME-UHPLC-MS/MS method presented lower LOQ values than SPME-nanoESI-MS/MS. The additional separation (chromatographic column) favored the detectability of LC-MS/MS method. However, the SPME-nano-ESI-MS/MS decrease the total analysis time, due to significant reductions in desorption and detection times.
Collapse
|
27
|
Grandy JJ, Lashgari M, Heide HV, Poole J, Pawliszyn J. Introducing a mechanically robust SPME sampler for the on-site sampling and extraction of a wide range of untargeted pollutants in environmental waters. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2019; 252:825-834. [PMID: 31202135 DOI: 10.1016/j.envpol.2019.06.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Revised: 06/02/2019] [Accepted: 06/04/2019] [Indexed: 06/09/2023]
Abstract
The present study introduces a mechanically robust, sealable SPME sampler for the on-site sampling and extraction of a wide range of untargeted pollutants in environmental waters. Spray-coating and dip coating methodologies were used to coat the surfaces of six stainless steel bolts with a layer of HLB/PAN particles, which served as the extractive substrate in the proposed device. In addition, this sampler was designed to withstand rough handling, long storage times, and various environmental conditions. In order to identify whether the sampler was able to stabilize extracted compounds for long periods of time, the effects of storage time and temperature were evaluated. The results of these tests showed no significant differences in the quantity and quality of the extracted chemicals following 12 days storage at room temperature, thus confirming the device's suitability for use at sampling sites that are far away from the laboratory facilities. The proposed device was also used to perform extraction and untargeted analyses of river waters in five different geographical locations. The constituent chemicals in the samplers were analyzed and determined using high-resolution HPLC-Orbitrap MS. Toxin and Toxin-Target Database was used as a reference database for toxins and environmental contaminants. Ultimately, over 80 tentative chemicals with widely varying hydrophobicities ranging within -2.43 < logP <11.9-including drugs, metabolites, wide ranges of toxins, pesticide, and insecticides-were identified in the samplers used in the different rivers. The log P values for the tentative analytes confirmed that the introduced device is suitable for the extraction and trace analysis of wide ranges of targeted and untargeted pollutants.
Collapse
Affiliation(s)
- Jonathan J Grandy
- University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L3G1, Canada
| | - Maryam Lashgari
- University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L3G1, Canada
| | - Harmen Vander Heide
- University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L3G1, Canada
| | - Justen Poole
- University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L3G1, Canada
| | - Janusz Pawliszyn
- University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L3G1, Canada; Lehn Institute of Functional Materials (LIFM), Sun Yat-sen University, Guangzhou, 510275, China.
| |
Collapse
|
28
|
In vitro selection of tacrolimus binding aptamer by systematic evolution of ligands by exponential enrichment method for the development of a fluorescent aptasensor for sensitive detection of tacrolimus. J Pharm Biomed Anal 2019; 177:112853. [PMID: 31499431 DOI: 10.1016/j.jpba.2019.112853] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2019] [Revised: 08/29/2019] [Accepted: 08/31/2019] [Indexed: 01/08/2023]
Abstract
Tacrolimus (TAC) is an immunosuppressant for preventing solid-organ transplant rejection. Because of its narrow therapeutic window, analytical methods which can detect TAC in serum samples with high accuracy and reliability are required. In this study, specific aptamers (Apt122 and Apt125) for TAC were isolated via systematic evolution of ligands by exponential enrichment method using magnetic beads to immobilize the target. After determination of binding constants of aptamers by flow cytometry analysis, Apt122 was selected and labeled with ATTO 647 N as a fluorophore to develop a fluorescent sensing platform for detection of TAC using graphene oxide (GO) as a fluorescence quencher. The designed aptasensor could detect TAC in phosphate buffer saline (10 mM PBS) and serum samples with detection limits as low as 1.4 and 2.5 nM, respectively.
Collapse
|
29
|
Kasperkiewicz A, Gómez-Ríos GA, Hein D, Pawliszyn J. Breaching the 10 Second Barrier of Total Analysis Time for Complex Matrices via Automated Coated Blade Spray. Anal Chem 2019; 91:13039-13046. [DOI: 10.1021/acs.analchem.9b03225] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
| | | | - Dietmar Hein
- Professional Analytical System (PAS) Technology, 99441 Magdala, Germany
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
30
|
Filipiak W, Bojko B. SPME in clinical, pharmaceutical, and biotechnological research – How far are we from daily practice? Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.02.029] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
31
|
Pu F, Chiang S, Zhang W, Ouyang Z. Direct sampling mass spectrometry for clinical analysis. Analyst 2019; 144:1034-1051. [PMID: 30520890 DOI: 10.1039/c8an01722k] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Direct sampling mass spectrometry (MS) has been advancing aggressively, showing immense potential in translating MS into the clinical field. Unlike traditional MS analysis involving extensive sample preparation and chromatographic separation, quick and simple procedures with minimal sample pretreatment or purification became available with direct sampling. An overview of the development in this field is provided, including some representative ambient ionization and fast extraction methods. Quantitative applications of these methods are emphasized and their efficacy are highlighted from a clinical aspect; non-quantitative applications in clinical analysis are also discussed. This review also discusses the integration of direct sampling MS with miniature mass spectrometers and its future outlook as an emerging clinical tool for point-of-care analysis.
Collapse
Affiliation(s)
- Fan Pu
- State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
| | | | | | | |
Collapse
|
32
|
|
33
|
Seyyal E, Evans-Nguyen T. Online Sol-gel Capillary Microextraction-Mass Spectrometry (CME-MS) Analysis of Illicit Drugs. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:595-604. [PMID: 30796621 DOI: 10.1007/s13361-018-02127-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Revised: 12/14/2018] [Accepted: 12/15/2018] [Indexed: 06/09/2023]
Abstract
Providing rapid and sensitive sample cleanup, sol-gel capillary microextraction (CME) is a form of solid phase microextraction (SPME). The capillary format of CME couples easily with mass spectrometry (MS) by employing sol-gel sorbent coatings in inexpensive fused silica capillaries. By leveraging the syringe pump and six-port valve readily available on the commercial MS, we can obviate the need for chromatography for samples as complex as urine in quantitative assays. Two different sol-gel materials were studied as microextraction sorbents: one with a single ligand of octadecyl (C18) and the other with a dual-ligand combination of C18 and phenyl (Phe) groups. The CME-MS method was optimized for flow rate and solvent desorption and studied for overall microextraction performance between the two sorbents studied. We extract illicit drugs including cocaine, heroin, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, and oxycodone, proving good run-to-run reproducibility (RSD% < 10%) and low detection limits (< 10 ng mL-1). The dual-ligand sorbent demonstrated superior performance due to typical hydrophobic properties of C18 as well as potential π-π interactions of the Phe functionality and the aromatic moiety common to many drugs. This study demonstrates the advantage of fine-tuning sol-gel sorbents for application-specific CME-MS. We apply our method to the analysis of various drugs in synthetic and human urine samples and show low carryover effect (~ 5%) and low matrix effect in the presence of the urine matrix. Thus, the sol-gel CME-MS technique described herein stands to be an attractive alternative to other SPME-MS techniques.
Collapse
Affiliation(s)
- Emre Seyyal
- Department of Chemistry, University of South Florida, 4202 E. Fowler Avenue, CHE 205, Tampa, FL, 33620-5250, USA
| | - Theresa Evans-Nguyen
- Department of Chemistry, University of South Florida, 4202 E. Fowler Avenue, CHE 205, Tampa, FL, 33620-5250, USA.
| |
Collapse
|
34
|
|
35
|
A critical outlook on recent developments and applications of matrix compatible coatings for solid phase microextraction. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2018.12.019] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
36
|
Khaled A, Gionfriddo E, Acquaro V, Singh V, Pawliszyn J. Development and validation of a fully automated solid phase microextraction high throughput method for quantitative analysis of multiresidue veterinary drugs in chicken tissue. Anal Chim Acta 2018; 1056:34-46. [PMID: 30797459 DOI: 10.1016/j.aca.2018.12.044] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 12/20/2018] [Accepted: 12/21/2018] [Indexed: 12/24/2022]
Abstract
This paper presents the development and validation of a fully automated, high-throughput multiclass, multiresidue method for quantitative analysis of 77 veterinary drugs in chicken muscle via direct immersion solid phase microextraction (DI-SPME) and ultra-high pressure liquid chromatography-electrospray ionization - tandem mass spectrometry (UHPLC-ESI-MS/MS). The selected drugs represent more than 12 different classes of drugs characterized by varying physical and chemical properties. A Hydrophilic-lipophilic balance (HLB)/polyacrylonitrile (PAN) extraction phase, prepared using HLB particles synthesized in-house, yielded the best extraction/desorption performance among four different SPME extraction phases evaluated in the current work. The developed SPME method was optimized in terms of SPME coating and geometry, desorption solvent, extraction and rinsing conditions, and extraction and desorption times. Multivariate analysis was performed to determine the optimal desorption solvent for the proposed application. The developed method was validated according to the Food and Drug Administration (FDA) guidelines, taking into account Canadian maximum residue limits (MRLs) and US maximum tolerance levels for veterinary drugs in meat. Method accuracy ranged from 80 to 120% for at least 73 compounds, with relative standard deviation of 1-15%. Inter-day precision ranged from 4 to 15% for 70 compounds. Determination coefficients values were higher than 0.991 for all compounds under study with no significant lack of fit (p > 0.05) at the 5% level. In terms of limits of quantitation, the method was able to meet both Canadian and US regulatory levels for all compounds under study.
Collapse
Affiliation(s)
- Abir Khaled
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada
| | - Emanuela Gionfriddo
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada; Department of Chemistry and Biochemistry, The University of Toledo, Toledo, OH, USA
| | - Vinicius Acquaro
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada; Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, SP, Brazil
| | - Varoon Singh
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario, N2L 3G1, Canada.
| |
Collapse
|
37
|
ZHANG XL, ZHANG H, WANG XC, HUANG KK, WANG D, CHEN HW. Advances in Ambient Ionization for Mass Spectrometry. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2018. [DOI: 10.1016/s1872-2040(18)61122-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
38
|
Roszkowska A, Miękus N, Bączek T. Application of solid-phase microextraction in current biomedical research. J Sep Sci 2018; 42:285-302. [DOI: 10.1002/jssc.201800785] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Revised: 10/02/2018] [Accepted: 10/02/2018] [Indexed: 12/19/2022]
Affiliation(s)
- Anna Roszkowska
- Department of Pharmaceutical Chemistry; Faculty of Pharmacy; Medical University of Gdańsk; Gdańsk Poland
| | - Natalia Miękus
- Department of Pharmaceutical Chemistry; Faculty of Pharmacy; Medical University of Gdańsk; Gdańsk Poland
- Department of Animal and Human Physiology; Faculty of Biology; University of Gdańsk; Gdańsk Poland
| | - Tomasz Bączek
- Department of Pharmaceutical Chemistry; Faculty of Pharmacy; Medical University of Gdańsk; Gdańsk Poland
- Department of Nursing; Faculty of Health Sciences; Pomeranian University of Słupsk; Słupsk Poland
| |
Collapse
|
39
|
Tascon M, Alam MN, Gómez-Ríos GA, Pawliszyn J. Development of a Microfluidic Open Interface with Flow Isolated Desorption Volume for the Direct Coupling of SPME Devices to Mass Spectrometry. Anal Chem 2018; 90:2631-2638. [PMID: 29388761 DOI: 10.1021/acs.analchem.7b04295] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Technologies that efficiently integrate the sampling and sample preparation steps with direct introduction to mass spectrometry (MS), providing simple and sensitive analytical workflows as well as capabilities for automation, can generate a great impact in a vast variety of fields, such as in clinical, environmental, and food-science applications. In this study, a novel approach that facilitates direct coupling of Bio-SPME devices to MS using a microfluidic design is presented. This technology, named microfluidic open interface (MOI), which operates under the concept of flow-isolated desorption volume, consists of an open-to-ambient desorption chamber (V ≤ 7 μL) connected to an ionization source. Subsequently, compounds of interest are transported to the ionization source by means of the self-aspiration process intrinsic of these interfaces. Thus, any ionization technology that provides a reliable and constant suction, such as electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), or inductively coupled plasma ionization (ICP), can be hyphenated to MOI. Using this setup, the desorption chamber is used to release target compounds from the coating, while the isolation of the flow enables the ionization source to be continuously fed with solvent, all without the necessity of employment of additional valves. As a proof of concept, the design was applied to an ESI-MS/MS system for experimental validation. Furthermore, numerical simulations were undertaken to provide a detailed understanding of the fluid flow pattern inside the interface, then used to optimize the system for better efficiency. The analytical workflow of the developed Bio-SPME-MOI-MS setup consists of the direct immersion of SPME fibers into the matrix to extract/enrich analytes of interest within a short period of time, followed by a rinsing step with water to remove potentially adhering proteins, salts, and/or other interfering compounds. Next, the fiber is inserted into the MOI for desorption of compounds of interest. Finally, the volume contained in the chamber is drained and moved toward the electrospray needle for ionization and direct introduction to MS. Aiming to validate the technology, the fast determination of selected immunosuppressive drugs (e.g., tacrolimus, cyclosporine, sirolimus, and everolimus) from 100 μL of whole blood was assessed. Limits of quantitation in the subppb range were obtained for all studied compounds. Good linearity (r2 ≥ 0.99) and excellent precision, with (8%) and without (14%) internal standard correction, were attained.
Collapse
Affiliation(s)
- Marcos Tascon
- Department of Chemistry, University of Waterloo , Waterloo, Ontario N2L 3G1, Canada
| | - Md Nazmul Alam
- Department of Chemistry, University of Waterloo , Waterloo, Ontario N2L 3G1, Canada
| | | | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo , Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
40
|
Reyes-Garcés N, Gionfriddo E, Gómez-Ríos GA, Alam MN, Boyacı E, Bojko B, Singh V, Grandy J, Pawliszyn J. Advances in Solid Phase Microextraction and Perspective on Future Directions. Anal Chem 2017; 90:302-360. [DOI: 10.1021/acs.analchem.7b04502] [Citation(s) in RCA: 402] [Impact Index Per Article: 57.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
| | | | | | - Md. Nazmul Alam
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Ezel Boyacı
- Department of Chemistry, Middle East Technical University, Ankara 06800, Turkey
| | - Barbara Bojko
- Department of Pharmacodynamics and Molecular Pharmacology, Faculty of Pharmacy, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Toruń, 85-067 Bydgoszcz, Poland
| | - Varoon Singh
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Jonathan Grandy
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Ontario, Canada N2L 3G1
| |
Collapse
|