1
|
Chen J, Chen L, Zhang Y, Xiang S, Zhang R, Shen Y, Liao J, Xie H, Yang J. Development of a Time-Resolved Fluorescent Microsphere Test Strip for Rapid, On-Site, and Sensitive Detection of Picoxystrobin in Vegetables. Foods 2024; 13:423. [PMID: 38338560 PMCID: PMC10855143 DOI: 10.3390/foods13030423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Revised: 01/21/2024] [Accepted: 01/22/2024] [Indexed: 02/12/2024] Open
Abstract
Picoxystrobin (PIC) is a fungicide extensively used for disease control in both crops and vegetables. Residues of PIC in vegetables pose a potential threat to human health due to their accumulation in the food chain. In this study, a specific PIC monoclonal antibody (mAb) was developed by introducing a carboxylic acid arm into PIC and subsequently preparing a hapten and an artificial antigen. A sensitive and rapid time-resolved fluorescence immunochromatographic assay (TRFICA) was established based on the mAb. Subsequently, using a time-resolved fluorescent microsphere (TRFM) as signal probe, mAbs and microspheres were covalently coupled. The activated pH, the mAb diluents, the mAb amount, and the probe amount were optimized. Under optimized conditions, the quantitative limits of detection (qLOD) of PIC in cucumber, green pepper, and tomato using TRFICA were established at 0.61, 0.26, and 3.44 ng/mL, respectively; the 50% inhibiting concentrations (IC50) were 11.76, 5.29, and 37.68 ng/mL, respectively. The linear ranges were 1.81-76.71, 0.80-35.04, and 8.32-170.55 ng/mL, respectively. The average recovery in cucumber, green pepper, and tomato samples ranged from 79.8% to 105.0%, and the corresponding coefficients of variation (CV) were below 14.2%. In addition, 15 vegetable samples were selected and compared with the results obtained using ultra-performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS). The results revealed a high degree of concordance between the proposed method and UPLC-MS/MS. In conclusion, the devised TRFICA method is a valuable tool for rapid, on-site, and highly sensitive detection of PIC residues in vegetables.
Collapse
Affiliation(s)
- Junjie Chen
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China; (J.C.); (L.C.); (Y.Z.); (S.X.); (R.Z.); (Y.S.); (J.L.); (H.X.)
| | - Lidan Chen
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China; (J.C.); (L.C.); (Y.Z.); (S.X.); (R.Z.); (Y.S.); (J.L.); (H.X.)
| | - Yongyi Zhang
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China; (J.C.); (L.C.); (Y.Z.); (S.X.); (R.Z.); (Y.S.); (J.L.); (H.X.)
| | - Siyi Xiang
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China; (J.C.); (L.C.); (Y.Z.); (S.X.); (R.Z.); (Y.S.); (J.L.); (H.X.)
| | - Ruizhou Zhang
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China; (J.C.); (L.C.); (Y.Z.); (S.X.); (R.Z.); (Y.S.); (J.L.); (H.X.)
| | - Yudong Shen
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China; (J.C.); (L.C.); (Y.Z.); (S.X.); (R.Z.); (Y.S.); (J.L.); (H.X.)
| | - Jiaming Liao
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China; (J.C.); (L.C.); (Y.Z.); (S.X.); (R.Z.); (Y.S.); (J.L.); (H.X.)
| | - Huahui Xie
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China; (J.C.); (L.C.); (Y.Z.); (S.X.); (R.Z.); (Y.S.); (J.L.); (H.X.)
| | - Jinyi Yang
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China; (J.C.); (L.C.); (Y.Z.); (S.X.); (R.Z.); (Y.S.); (J.L.); (H.X.)
- Wens Institute, Wens Foodstuff Groups Co., Ltd., Yunfu 527400, China
| |
Collapse
|
2
|
Li G, Sun J, Li J, Zhang Y, Huang J, Yue F, Dong H, Li F, Xu H, Guo Y, Guo Y, Sun X. Paper-based biosensors relying on core biological immune scaffolds for the detection of procymidone in vegetables. Talanta 2023; 265:124843. [PMID: 37399648 DOI: 10.1016/j.talanta.2023.124843] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 06/05/2023] [Accepted: 06/19/2023] [Indexed: 07/05/2023]
Abstract
In order to achieve a highly sensitive detection of procymidone in vegetables, three paper-based biosensors based on a core biological immune scaffold (CBIS) were developed, which were time-resolved fluorescence immunochromatography strips with Europium (III) oxide (Eu-TRFICS). Goat anti-mouse IgG and europium oxide time-resolved fluorescent microspheres formed secondary fluorescent probes. CBIS was formed by secondary fluorescent probes and procymidone monoclonal antibody (PCM-Ab). The first type of Eu-TRFICS (Eu-TRFICS-(1)) fixed secondary fluorescent probes on a conjugate pad, and PCM-Ab was mixed with a sample solution. The second type of Eu-TRFICS (Eu-TRFICS-(2)) fixed CBIS on the conjugate pad. The third type of Eu-TRFICS (Eu-TRFICS-(3)) was directly mixed CBIS with the sample solution. They solved the problems of steric hindrance of antibody labeling, insufficient exposure of antigen recognition region and easy loss of activity in traditional methods. They realized multi-dimensional labeling and directional coupling. They replaced the loss of antibody activity. And the three types of Eu-TRFICS were compared, among which Eu-TRFICS-(1) was the best detection choice. Antibody usage was reduced by 25% and sensitivity was increased by 3 times. Its detection range was 1-800 ng/mL, the limit of detection (LOD) was 0.12 ng/mL with the visible LOD (vLOD) of 5 ng/mL.
Collapse
Affiliation(s)
- Gaozhen Li
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China
| | - Jiashuai Sun
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China
| | - Jiahuan Li
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China
| | - Yaoli Zhang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China
| | - Jingcheng Huang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China
| | - Fengling Yue
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China
| | - Haowei Dong
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China
| | - Falan Li
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China
| | - Huihui Xu
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China
| | - Yanyin Guo
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China
| | - Yemin Guo
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China.
| | - Xia Sun
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong, 255049, China.
| |
Collapse
|
3
|
Yuan H, Chen P, Wan C, Li Y, Liu BF. Merging microfluidics with luminescence immunoassays for urgent point-of-care diagnostics of COVID-19. Trends Analyt Chem 2022; 157:116814. [PMID: 36373139 PMCID: PMC9637550 DOI: 10.1016/j.trac.2022.116814] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 10/29/2022] [Accepted: 10/30/2022] [Indexed: 11/09/2022]
Abstract
The Coronavirus disease 2019 (COVID-19) outbreak has urged the establishment of a global-wide rapid diagnostic system. Current widely-used tests for COVID-19 include nucleic acid assays, immunoassays, and radiological imaging. Immunoassays play an irreplaceable role in rapidly diagnosing COVID-19 and monitoring the patients for the assessment of their severity, risks of the immune storm, and prediction of treatment outcomes. Despite of the enormous needs for immunoassays, the widespread use of traditional immunoassay platforms is still limited by high cost and low automation, which are currently not suitable for point-of-care tests (POCTs). Microfluidic chips with the features of low consumption, high throughput, and integration, provide the potential to enable immunoassays for POCTs, especially in remote areas. Meanwhile, luminescence detection can be merged with immunoassays on microfluidic platforms for their good performance in quantification, sensitivity, and specificity. This review introduces both homogenous and heterogenous luminescence immunoassays with various microfluidic platforms. We also summarize the strengths and weaknesses of the categorized methods, highlighting their recent typical progress. Additionally, different microfluidic platforms are described for comparison. The latest advances in combining luminescence immunoassays with microfluidic platforms for POCTs of COVID-19 are further explained with antigens, antibodies, and related cytokines. Finally, challenges and future perspectives were discussed.
Collapse
Affiliation(s)
- Huijuan Yuan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Peng Chen
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Chao Wan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yiwei Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Bi-Feng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| |
Collapse
|
4
|
Chen J, Jin Y, Ren T, Wang S, Wang X, Zhang F, Tang Y. A novel terbium (III) and aptamer-based probe for label-free detection of three fluoroquinolones in honey and water samples. Food Chem 2022; 386:132751. [PMID: 35334319 DOI: 10.1016/j.foodchem.2022.132751] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 02/16/2022] [Accepted: 03/16/2022] [Indexed: 11/18/2022]
Abstract
Fluoroquinolones, a family of synthetic broad-spectrum antibiotics, are widely used in clinical medicine, farm animals and aquaculture. Residues of fluoroquinolones in samples have attracted much attention because of growing food safety and public health concerns. Here, a novel Tb3+ ion-enrofloxacin aptamer coordination probe was prepared to develop a sensitive and rapid label-free fluorescence assay for specific detection three fluoroquinolones. In presence of the target, Tb3+ ion- enrofloxacin aptamer probe specifically bound with enrofloxacin, norfloxacin and ciprofloxacin, leading to a sharp increase in fluorescence emission of the probe. Under the optimized conditions, fluorescence increased linearly in the 1.0-100.0 ng/mL range for the three fluoroquinolones, with 0.053 ng/mL limit of detection for ciprofloxacin, 0.020 ng/mL limit of detection for norfloxacin and 0.061 ng/mL limit of detection for enrofloxacin. Satisfactory recovery (80.10-102.48%) in spiked honey and water samples were obtained for the three fluoroquinolones with relative standard deviations between 0.21% and 5.44% (n = 3).
Collapse
Affiliation(s)
- Jin'ai Chen
- College of Food Science and Technology, Hebei Agricultural University, Baoding 071001, China; College of Food Science & Project Engineering, Bohai University, Jinzhou 121013, China
| | - Yuting Jin
- College of Food Science and Technology, Hebei Agricultural University, Baoding 071001, China; College of Food Science & Project Engineering, Bohai University, Jinzhou 121013, China
| | - Taotao Ren
- College of Food Science and Technology, Hebei Agricultural University, Baoding 071001, China; College of Food Science & Project Engineering, Bohai University, Jinzhou 121013, China
| | - Shuo Wang
- College of Food Science and Technology, Hebei Agricultural University, Baoding 071001, China; Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin 300071, China
| | - Xianghong Wang
- College of Food Science and Technology, Hebei Agricultural University, Baoding 071001, China
| | - Fuyuan Zhang
- College of Food Science and Technology, Hebei Agricultural University, Baoding 071001, China
| | - Yiwei Tang
- College of Food Science and Technology, Hebei Agricultural University, Baoding 071001, China.
| |
Collapse
|
5
|
Deng C, Li H, Qian S, Fu P, Zhou H, Zheng J, Wang Y. An Emerging Fluorescent Carbon Nanobead Label Probe for Lateral Flow Assays and Highly Sensitive Screening of Foodborne Toxins and Pathogenic Bacteria. Anal Chem 2022; 94:11514-11520. [PMID: 35959591 DOI: 10.1021/acs.analchem.2c01430] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
By virtue of the fascinating merits of low cost, rapid screening, and on-site detection, fluorescence lateral flow assays (FLFAs) have attracted considerable attention. Their detection limits are closely associated with the label probes used. The development of high-performance and robust phosphors remains a great challenge. Herein, we presented a new label probe, i.e., fluorescent carbon nanobeads (FCNBs), for FLFAs. Monodispersive, water-soluble, and highly emissive FCNBs were facilely prepared via a hydrothermal carbonization manner. Their abundant amino groups were beneficial for versatile surface functionalization. After being modified by biomolecules, the fabricated FCNB reporter probes were adopted for the construction of lateral flow test strips toward representative foodborne toxins, i.e., aflatoxin B1 (AFB1), and pathogenic bacteria, i.e., Staphylococcus aureus (S. aureus), respectively. The detection limits (0.01 ng/mL for AFB1 and 102 cfu/mL for S. aureus) were about 1 or 2 orders of magnitude lower than most reported methods. Furthermore, the proposed test strips were successfully applied for the quantitative, accurate, and rapid screening of AFB1 and S. aureus in food samples. This work provided a promising label probe for FLFAs and would open the opportunity to exploit a sensing platform by modifying different ligands onto the FCNBs.
Collapse
Affiliation(s)
- Chen Deng
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P.R. China.,Cixi Institute of Biomedical Engineering, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences (CAS), Ningbo 315300, P.R. China
| | - Hui Li
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, P.R. China
| | - Sihua Qian
- Cixi Institute of Biomedical Engineering, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences (CAS), Ningbo 315300, P.R. China
| | - Pan Fu
- Cixi Institute of Biomedical Engineering, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences (CAS), Ningbo 315300, P.R. China
| | - Hualan Zhou
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P.R. China
| | - Jianping Zheng
- Cixi Institute of Biomedical Engineering, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences (CAS), Ningbo 315300, P.R. China
| | - Yuhui Wang
- Cixi Institute of Biomedical Engineering, Ningbo Institute of Materials Technology & Engineering, Chinese Academy of Sciences (CAS), Ningbo 315300, P.R. China
| |
Collapse
|
6
|
Improving the Fluorescence Intensity of Lanthanide-doped Microspheres via Incorporation of Lauryl Methacrylate: Synthesis and Their Application in C-reactive Protein Detection. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.130065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
7
|
Teng H, Li Q, Gou M, Liu G, Cao X, Lu J, Han Y, Yu Y, Gao Z, Song X, Dong W, Pang Y. Lamprey immunity protein enables early detection and recurrence monitoring for bladder cancer through recognizing Neu5Gc-modified uromodulin glycoprotein in urine. Biochim Biophys Acta Mol Basis Dis 2022; 1868:166493. [PMID: 35853560 DOI: 10.1016/j.bbadis.2022.166493] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 07/08/2022] [Accepted: 07/11/2022] [Indexed: 11/20/2022]
Abstract
The clinical management of bladder cancer (BCa) is hindered by the lack of reliable biomarkers. We aimed to investigate the potential of lamprey immunity protein (LIP), a lectin that specifically binds to multi-antennary sialylated N-glycolylneuraminic acid (Neu5Gc) structures on UMOD glycoproteins in the urine of BCa patients. Primary BCa patients had higher levels of LIP-bound Neu5Gc in urine than healthy participants and patients receiving postoperative treatment did. In addition, lectin chip assay and mass spectrometry were used to analyze the glycan chain structure, which can recognize the UMOD glycoprotein decorated with multi-antennary sialylated Neu5Gc structures. Furthermore, compared with urine samples from healthy patients (N = 2821, T/C = 0.12 ± 0.09) or benign patients (N = 360, T/C = 0.11 ± 0.08), the range of the urine T/C ratio detected using LIP test paper was 1.97 ± 0.32 in patients with bladder cancer (N = 518) with significant difference (P < 0.0001). Our results indicate that LIP may be a tool for early BCa identification, diagnosis, and monitoring. Neu5Gc-modified UMOD glycoproteins in urine and Neu5Gc-modified N-glycochains and sialyltransferases may function as potential markers in clinical trials.
Collapse
Affiliation(s)
- Hongming Teng
- College of Life Science, Liaoning Normal University, Dalian, Liaoning, China
| | - Qingwei Li
- College of Life Science, Liaoning Normal University, Dalian, Liaoning, China
| | - Meng Gou
- College of Life Science, Liaoning Normal University, Dalian, Liaoning, China
| | - Gang Liu
- College of Basic Medical Sciences, Dalian Medical University, Dalian, Liaoning, China
| | - Xu Cao
- College of Life Science, Liaoning Normal University, Dalian, Liaoning, China
| | - Jiali Lu
- College of Life Science, Liaoning Normal University, Dalian, Liaoning, China
| | - Yinglun Han
- College of Life Science, Liaoning Normal University, Dalian, Liaoning, China
| | - Yang Yu
- Department of Urology, The Second Hospital of Dalian Medical University, Dalian, Liaoning, China
| | - Zhanfeng Gao
- Department of Urology, Dalian Municipal Central Hospital affiliated to Dalian Medical University, Dalian, China
| | - Xiaoping Song
- Respiratory Medicine, Affiliated Zhong shan Hospital of Dalian University, Dalian, China
| | - Weijie Dong
- College of Basic Medical Sciences, Dalian Medical University, Dalian, Liaoning, China.
| | - Yue Pang
- College of Life Science, Liaoning Normal University, Dalian, Liaoning, China.
| |
Collapse
|