1
|
Bousso I, Genin G, Thomopoulos S. Achieving tendon enthesis regeneration across length scales. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2024; 31:100547. [PMID: 39219714 PMCID: PMC11364215 DOI: 10.1016/j.cobme.2024.100547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/04/2024]
Abstract
Surgical reattachment of tendon to bone is a clinical challenge, with unacceptably high retear rates in the early period after repair. A primary reason for these repeated tears is that the multiscale toughening mechanisms found at the healthy tendon enthesis are not regenerated during tendon-to-bone healing. The need for technologies to improve these outcomes is pressing, and the tissue engineering community has responded with many advances that hold promise for eventually regenerating the multiscale tissue interface that transfers loads between the two dissimilar materials, tendon, and bone. This review provides an assessment of the state of these approaches, with the aim of identifying a critical agenda for future progress.
Collapse
Affiliation(s)
- Ismael Bousso
- Department of Biomedical Engineering, Columbia University, New York, NY USA
| | - Guy Genin
- Department of Mechanical Engineering & Materials Science, Washington University, St. Louis, MO USA
| | - Stavros Thomopoulos
- Department of Biomedical Engineering, Columbia University, New York, NY USA
- Department of Orthopaedic Surgery, Columbia University, New York, NY USA
| |
Collapse
|
2
|
Liu N, Jiang J, Liu T, Chen H, Jiang N. Compositional, Structural, and Biomechanical Properties of Three Different Soft Tissue-Hard Tissue Insertions: A Comparative Review. ACS Biomater Sci Eng 2024; 10:2659-2679. [PMID: 38697939 DOI: 10.1021/acsbiomaterials.3c01796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
Abstract
Connective tissue attaches to bone across an insertion with spatial gradients in components, microstructure, and biomechanics. Due to regional stress concentrations between two mechanically dissimilar materials, the insertion is vulnerable to mechanical damage during joint movements and difficult to repair completely, which remains a significant clinical challenge. Despite interface stress concentrations, the native insertion physiologically functions as the effective load-transfer device between soft tissue and bone. This review summarizes tendon, ligament, and meniscus insertions cross-sectionally, which is novel in this field. Herein, the similarities and differences between the three kinds of insertions in terms of components, microstructure, and biomechanics are compared in great detail. This review begins with describing the basic components existing in the four zones (original soft tissue, uncalcified fibrocartilage, calcified fibrocartilage, and bone) of each kind of insertion, respectively. It then discusses the microstructure constructed from collagen, glycosaminoglycans (GAGs), minerals and others, which provides key support for the biomechanical properties and affects its physiological functions. Finally, the review continues by describing variations in mechanical properties at the millimeter, micrometer, and nanometer scale, which minimize stress concentrations and control stretch at the insertion. In summary, investigating the contrasts between the three has enlightening significance for future directions of repair strategies of insertion diseases and for bioinspired approaches to effective soft-hard interfaces and other tough and robust materials in medicine and engineering.
Collapse
Affiliation(s)
- Nian Liu
- West China School of Stomatology, Sichuan University, Chengdu, Sichuan 610207, China
| | - Jialing Jiang
- West China School of Stomatology, Sichuan University, Chengdu, Sichuan 610207, China
| | - Tiancheng Liu
- West China Hospital, Sichuan University, Chengdu, Sichuan 610207, China
| | - Haozhe Chen
- State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan 610041, China
| | - Nan Jiang
- State Key Laboratory of Oral Diseases, & National Clinical Research Center for Oral Disease, & West China Hospital of Stomatology and the Research Center for Nano Biomaterials, Analytical & Testing Center, Sichuan University, Chengdu, Sichuan 610041, China
| |
Collapse
|
3
|
Li Y, Zhou M, Zheng W, Yang J, Jiang N. Scaffold-based tissue engineering strategies for soft-hard interface regeneration. Regen Biomater 2022; 10:rbac091. [PMID: 36683751 PMCID: PMC9847541 DOI: 10.1093/rb/rbac091] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 10/22/2022] [Accepted: 10/26/2022] [Indexed: 11/13/2022] Open
Abstract
Repairing injured tendon or ligament attachments to bones (enthesis) remains costly and challenging. Despite superb surgical management, the disorganized enthesis newly formed after surgery accounts for high recurrence rates after operations. Tissue engineering offers efficient alternatives to promote healing and regeneration of the specialized enthesis tissue. Load-transmitting functions thus can be restored with appropriate biomaterials and engineering strategies. Interestingly, recent studies have focused more on microstructure especially the arrangement of fibers since Rossetti successfully demonstrated the variability of fiber underspecific external force. In this review, we provide an important update on the current strategies for scaffold-based tissue engineering of enthesis when natural structure and properties are equally emphasized. We firstly described compositions, structures and features of natural enthesis with their special mechanical properties highlighted. Stimuli for growth, development and healing of enthesis widely used in popular strategies are systematically summarized. We discuss the fabrication of engineering scaffolds from the aspects of biomaterials, techniques and design strategies and comprehensively evaluate the advantages and disadvantages of each strategy. At last, this review pinpoints the remaining challenges and research directions to make breakthroughs in further studies.
Collapse
Affiliation(s)
| | | | - Wenzhuo Zheng
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Disease, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | | | - Nan Jiang
- Correspondence address. E-mail: (N.J.); (J.Y.)
| |
Collapse
|
4
|
Golman M, Birman V, Thomopoulos S, Genin GM. Enthesis strength, toughness and stiffness: an image-based model comparing tendon insertions with varying bony attachment geometries. J R Soc Interface 2021; 18:20210421. [PMID: 34932930 PMCID: PMC8692040 DOI: 10.1098/rsif.2021.0421] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 11/25/2021] [Indexed: 12/24/2022] Open
Abstract
Tendons of the body differ dramatically in their function, mechanics and range of motion, but all connect to bone via an enthesis. Effective force transfer at the enthesis enables joint stability and mobility, with strength and stiffness arising from a fibrous architecture. However, how enthesis toughness arises across tendons with diverse loading orientations remains unclear. To study this, we performed simultaneous imaging of the bone and tendon in entheses that represent the range of tendon-to-bone insertions and extended a mathematical model to account for variations in insertion and bone geometry. We tested the hypothesis that toughness, across a range of tendon entheses, could be explained by differences observed in interactions between fibre architecture and bone architecture. In the model, toughness arose from fibre reorientation, recruitment and rupture, mediated by interactions between fibres at the enthesis and the bony ridge abutting it. When applied to tendons sometimes characterized as either energy-storing or positional, the model predicted that entheses of the former prioritize toughness over strength, while those of the latter prioritize consistent stiffness across loading directions. Results provide insight into techniques for surgical repair of tendon-to-bone attachments, and more broadly into mechanisms for the attachment of highly dissimilar materials.
Collapse
Affiliation(s)
- Mikhail Golman
- Columbia University, Black Building, Room 1408, 650 W 168 ST, New York, NY 10032-3702, USA
| | - Victor Birman
- Missouri University of Science and Technology, Rolla, MO 65409, USA
| | - Stavros Thomopoulos
- Columbia University, Black Building, Room 1408, 650 W 168 ST, New York, NY 10032-3702, USA
| | - Guy M. Genin
- Washington University, Jubel Hall, Room 103F, 1 Brookings Drive, St Louis, MO 63130, USA
| |
Collapse
|
5
|
Chen P, Li L, Dong L, Wang S, Huang Z, Qian Y, Wang C, Liu W, Yang L. Gradient Biomineralized Silk Fibroin Nanofibrous Scaffold with Osteochondral Inductivity for Integration of Tendon to Bone. ACS Biomater Sci Eng 2020; 7:841-851. [PMID: 33715375 DOI: 10.1021/acsbiomaterials.9b01683] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Enthesis injury repair remains a huge challenge because of the unique biomolecular composition, microstructure, and mechanics in the interfacial region. Surgical reconstruction often creates new bone-scaffold interfaces with mismatched properties, resulting in poor osseointegration. To mimic the natural interface tissue structures and properties, we fabricated a nanofibrous scaffold with gradient mineral coating based on 10 × simulated body fluid (SBF) and silk fibroin (SF). We then characterized the physicochemical properties of the scaffold and evaluated its biological functions both in vitro and in vivo. The results showed that different areas of SF nanofibrous scaffold had varying levels of mineralization with disparate mechanical properties and had different effects on bone marrow mesenchymal stem cell growth and differentiation. Furthermore, the gradient scaffolds exhibited an enhancement of integration in the tendon-to-bone interface with a higher ultimate load and more fibrocartilage-like tissue formation. These findings demonstrate that the silk-based nanofibrous scaffold with gradient mineral coating can regulate the formation of interfacial tissue and has the potential to be applied in interface tissue engineering.
Collapse
Affiliation(s)
- Peixing Chen
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400044, P. R. China
| | - Linhao Li
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, P. R. China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100083, P. R. China
| | - Lili Dong
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400044, P. R. China
| | - Sixiang Wang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400044, P. R. China
| | - Zhi Huang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400044, P. R. China
| | - Yuna Qian
- Wenzhou Institute of Biomaterials & Engineering, University of Chinese Academy of Sciences, Wenzhou 325001, P. R. China
| | - Chunli Wang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400044, P. R. China
| | - Wanqian Liu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400044, P. R. China
| | - Li Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400044, P. R. China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing 100083, P. R. China
| |
Collapse
|
6
|
Avgoulas EI, Sutcliffe MPF, Linderman SW, Birman V, Thomopoulos S, Genin GM. Adhesive-based tendon-to-bone repair: failure modelling and materials selection. J R Soc Interface 2020; 16:20180838. [PMID: 30966948 DOI: 10.1098/rsif.2018.0838] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Surgical reattachment of tendon to bone is a procedure marked by high failure rates. For example, nearly all rotator cuff repairs performed on elderly patients with massive tears ultimately result in recurrence of tearing. These high failure rates have been attributed to stress concentrations that arise due to the mechanical mismatch between tendon and bone. Although recent studies have identified potential adhesives with mechanical properties tuned to alleviate these stress concentrations, and thereby delay the onset of failure, resistance to the progression of failure has not been studied. Here, we refined the space of adhesive material properties that can improve surgical attachment by considering the fracture process. Using cohesive zone modelling and physiologically relevant values of mode I and mode II adhesive fracture toughnesses, we predicted the maximum displacement and strength at failure of idealized, adhesively bonded tendon-to-bone repairs. Repair failure occurred due to excessive relative displacement of the tendon and bone tissues for strong and compliant adhesives. The failure mechanism shifted to rupture of the entire repair for stiffer adhesives below a critical shear strength. Results identified a narrow range of materials on an Ashby chart that are suitable for adhesive repair of tendon to bone, including a range of elastomers and porous solids.
Collapse
Affiliation(s)
- Evangelos I Avgoulas
- 1 Department of Engineering, University of Cambridge , Trumpington Street, Cambridge CB2 1PZ , UK
| | - Michael P F Sutcliffe
- 1 Department of Engineering, University of Cambridge , Trumpington Street, Cambridge CB2 1PZ , UK
| | - Stephen W Linderman
- 2 Department of Orthopaedic Surgery, Washington University School of Medicine , St Louis, MO 63131 , USA
| | - Victor Birman
- 3 Missouri Science and Technology Global-St Louis, and Department of Mechanical and Aerospace Engineering , St Louis, MO 63131 , USA
| | - Stavros Thomopoulos
- 4 Department of Orthopedic Surgery, Columbia University , New York, NY 10032 , USA.,5 Department of Biomedical Engineering, Columbia University , New York, NY 10032 , USA
| | - Guy M Genin
- 6 NSF Science and Technology Center for Engineering Mechanobiology, Department of Mechanical and Aerospace Engineering, Washington University , St Louis, MO 63130 , USA
| |
Collapse
|
7
|
Chen J, Chin A, Almarza AJ, Taboas JM. Hydrogel to guide chondrogenesis versus osteogenesis of mesenchymal stem cells for fabrication of cartilaginous tissues. ACTA ACUST UNITED AC 2020; 15:045006. [PMID: 31470441 DOI: 10.1088/1748-605x/ab401f] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The ideal combination of hydrogel components for regeneration of cartilage and cartilaginous interfaces is a significant challenge because control over differentiation into multiple lineages is necessary. Stabilization of the phenotype of stem cell derived chondrocytes is needed to avoid undesired progression to terminal hypertrophy and tissue mineralization. A novel ternary blend hydrogel composed of methacrylated poly(ethylene glycol) (PEG), gelatin, and heparin (PGH) was designed to guide chondrogenesis by bone marrow derived mesenchymal stem cells (BMSCs) and maintenance of their cartilaginous phenotype. The hydrogel material effects on chondrogenic and osteogenic differentiation by BMSCs were evaluated in comparison to methacrylated gelatin hydrogel (GEL), a conventional bioink used for both chondrogenic and osteogenic applications. PGH and GEL hydrogels were loaded with goat BMSCs and cultured in chondrogenic and osteogenic mediums in vitro over six weeks. The PGH showed no sign of mineral deposition in an osteogenic environment in vitro. To further evaluate material effects, the hydrogels were loaded with adult human BMSCs (hBMSCs) and transforming growth factor β-3 and grown in subcutaneous pockets in mice over eight weeks. Consistent with the in vitro results, the PGH had greater potential to induce chondrogenesis by BMSCs in vivo compared to the GEL as evidenced by elevated gene expression of chondrogenic markers, supporting its potential for stable cartilage engineering. The PGH also showed a greater percentage of GAG positive cells compared to the GEL. Unlike the GEL, the PGH hydrogel exhibited anti-osteogenic effects in vivo as evidenced by negative Von Kossa staining and suppressed gene expression of hypertrophic and osteogenic markers. By nature of their polymer composition alone, the PGH and GEL regulated BMSC differentiation down different osteochondral lineages. Thus, the PGH and GEL are promising hydrogels to regenerate stratified cartilaginous interfacial tissues in situ, such as the mandibular condyle surface, using undifferentiated BMSCs and a stratified scaffold design.
Collapse
Affiliation(s)
- Jingming Chen
- Department of Bioengineering; University of Pittsburgh, Pittsburgh, PA 15213, United States of America. Center for Craniofacial Regeneration; University of Pittsburgh, Pittsburgh, PA 15213, United States of America
| | | | | | | |
Collapse
|
8
|
Luo W, Cheng L, Yuan C, Wu Z, Yuan G, Hou M, Chen JY, Luo C, Li W. Preparation, characterization and evaluation of cellulose nanocrystal/poly(lactic acid) in situ nanocomposite scaffolds for tissue engineering. Int J Biol Macromol 2019; 134:469-479. [PMID: 31078594 DOI: 10.1016/j.ijbiomac.2019.05.052] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2019] [Revised: 04/26/2019] [Accepted: 05/08/2019] [Indexed: 12/23/2022]
Abstract
Cellulose nanocrystal (CNC)/poly(lactic acid) (PLA) in situ nanocomposite scaffolds were fabricated by in situ polymerization of lactic acid and CNC which was directly utilized as aqueous suspension, followed by a process of thermally induced phase separation. The CNC/PLA in situ nanocomposite porous scaffolds were characterized by mechanical test, protein adsorption, hemolysis test, in vitro degradation measurement, TEM, FTIR, SEM and WAXD. Compared to the PLA scaffold, the CNC/PLA in situ nanocomposite scaffolds showed a greatly increased compression modulus, an improved hemocompatibility and protein adsorption capacity. The inclusion of CNCs boosted the in vitro degradation of the in situ nanocomposite porous scaffolds and facilitated the deposition of Ca2+, CO32-, PO43- ions in simulated body fluid. Furthermore, cell cultures were carried out on the CNC/PLA in situ nanocomposite porous scaffolds. In comparison with the PLA scaffold, the in situ nanocomposite scaffolds improved cell attachment and enhanced cell proliferation, denoting low cytotoxicity and good cytocompatibility. It can therefore be concluded that such scaffolds with excellent mechanical property, biocompatibility, biomineralization capacity and bioactivity hold great potential for bone tissue engineering.
Collapse
Affiliation(s)
- Weihua Luo
- College of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China; Hunan Province Key Laboratory of Materials Surface & Interface Science and Technology, Central South University of Forestry and Technology, Changsha 410004, China; School of Human Ecology, The University of Texas at Austin, Austin, TX 78712, USA.
| | - Lianghao Cheng
- College of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China
| | - Caixia Yuan
- College of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China
| | - Zhiping Wu
- College of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China; Hunan Province Key Laboratory of Materials Surface & Interface Science and Technology, Central South University of Forestry and Technology, Changsha 410004, China
| | - Guangming Yuan
- College of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China; Hunan Province Key Laboratory of Materials Surface & Interface Science and Technology, Central South University of Forestry and Technology, Changsha 410004, China
| | - Mingxi Hou
- College of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha 410004, China
| | - Jonathan Y Chen
- School of Human Ecology, The University of Texas at Austin, Austin, TX 78712, USA
| | - Chunyi Luo
- College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou 450001, China
| | - Wei Li
- Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
| |
Collapse
|
9
|
Deymier AC, Schwartz AG, Cai Z, Daulton TL, Pasteris JD, Genin GM, Thomopoulos S. The multiscale structural and mechanical effects of mouse supraspinatus muscle unloading on the mature enthesis. Acta Biomater 2019; 83:302-313. [PMID: 30342287 DOI: 10.1016/j.actbio.2018.10.024] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Revised: 10/04/2018] [Accepted: 10/15/2018] [Indexed: 12/17/2022]
Abstract
The musculoskeletal system is sensitive to its loading environment; this is of particular concern under conditions such as disuse, paralysis, and extended-duration space flight. Although structural and mechanical changes to tendon and bone following paralysis and disuse are well understood, there is a pressing need to understand how this unloading affects the bone-tendon interface (enthesis); the location most prone to tears and injury. We therefore elucidated these effects of unloading in the entheses of adult mice shoulders that were paralyzed for 21 days by treatment with botulinum toxin A. Unloading significantly increased the extent of mechanical failure and was associated with structural changes across hierarchical scales. At the millimeter scale, unloading caused bone loss. At the micrometer scale, unloading decreased bioapatite crystal size and crystallographic alignment in the enthesis. At the nanometer scale, unloading induced compositional changes that stiffened the bioapatite/collagen composite tissue. Mathematical modeling and mechanical testing indicated that these factors combined to increase local elevations of stress while decreasing the ability of the tissue to absorb energy prior to failure, thereby increasing injury risk. These first observations of the multiscale effects of unloading on the adult enthesis provide new insight into the hierarchical features of structure and composition that endow the enthesis with increased resistance to failure. STATEMENT OF SIGNIFICANCE: The musculoskeletal system is sensitive to its loading environment; this is of particular concern under conditions such as disuse, paralysis, and extended-duration space flight. Although changes to tendon and bone following paralysis are understood, there is a pressing need to clarify how unloading affects the bone-tendon interface (enthesis), which is the location most prone to tears and injury. We elucidated the effects of enthesis unloading in adult mice shoulders showing, for the first time, that unloading significantly increased the risk and extent of mechanical failure and was associated with structural changes across hierarchical scales. These observations provide new insight into the hierarchical features of structure and composition that endow the enthesis with resilience. This knowledge can be used to develop more targeted treatments to improve mobility and function.
Collapse
Affiliation(s)
- Alix C Deymier
- Department of Biomedical Engineering, University of Connecticut, Farmington, CT, USA.
| | - Andrea G Schwartz
- Department of Orthopaedic Surgery, Washington University, St. Louis, MO, USA.
| | - Zhounghou Cai
- Advanced Photon Source, Argonne National Lab, Argonne, IL, USA.
| | - Tyrone L Daulton
- Department of Physics, Washington University, St. Louis, MO, USA; Institute of Materials Science and Engineering, Washington University, St. Louis, MO, USA.
| | - Jill D Pasteris
- Department of Earth and Planetary Science, Washington University, St. Louis, MO, USA.
| | - Guy M Genin
- Department of Mechanical Engineering and Materials Science, Washington University, St. Louis, MO, USA.
| | - Stavros Thomopoulos
- Department of Orthopedic Surgery, Columbia University, New York, NY, USA; Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| |
Collapse
|
10
|
Huang G, Li F, Zhao X, Ma Y, Li Y, Lin M, Jin G, Lu TJ, Genin GM, Xu F. Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment. Chem Rev 2017; 117:12764-12850. [PMID: 28991456 PMCID: PMC6494624 DOI: 10.1021/acs.chemrev.7b00094] [Citation(s) in RCA: 479] [Impact Index Per Article: 68.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The cell microenvironment has emerged as a key determinant of cell behavior and function in development, physiology, and pathophysiology. The extracellular matrix (ECM) within the cell microenvironment serves not only as a structural foundation for cells but also as a source of three-dimensional (3D) biochemical and biophysical cues that trigger and regulate cell behaviors. Increasing evidence suggests that the 3D character of the microenvironment is required for development of many critical cell responses observed in vivo, fueling a surge in the development of functional and biomimetic materials for engineering the 3D cell microenvironment. Progress in the design of such materials has improved control of cell behaviors in 3D and advanced the fields of tissue regeneration, in vitro tissue models, large-scale cell differentiation, immunotherapy, and gene therapy. However, the field is still in its infancy, and discoveries about the nature of cell-microenvironment interactions continue to overturn much early progress in the field. Key challenges continue to be dissecting the roles of chemistry, structure, mechanics, and electrophysiology in the cell microenvironment, and understanding and harnessing the roles of periodicity and drift in these factors. This review encapsulates where recent advances appear to leave the ever-shifting state of the art, and it highlights areas in which substantial potential and uncertainty remain.
Collapse
Affiliation(s)
- Guoyou Huang
- MOE Key Laboratory of Biomedical Information
Engineering, School of Life Science and Technology, Xi’an Jiaotong
University, Xi’an 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center
(BEBC), Xi’an Jiaotong University, Xi’an 710049, People’s
Republic of China
| | - Fei Li
- Bioinspired Engineering and Biomechanics Center
(BEBC), Xi’an Jiaotong University, Xi’an 710049, People’s
Republic of China
- Department of Chemistry, School of Science,
Xi’an Jiaotong University, Xi’an 710049, People’s Republic
of China
| | - Xin Zhao
- Bioinspired Engineering and Biomechanics Center
(BEBC), Xi’an Jiaotong University, Xi’an 710049, People’s
Republic of China
- Interdisciplinary Division of Biomedical
Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong,
People’s Republic of China
| | - Yufei Ma
- MOE Key Laboratory of Biomedical Information
Engineering, School of Life Science and Technology, Xi’an Jiaotong
University, Xi’an 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center
(BEBC), Xi’an Jiaotong University, Xi’an 710049, People’s
Republic of China
| | - Yuhui Li
- MOE Key Laboratory of Biomedical Information
Engineering, School of Life Science and Technology, Xi’an Jiaotong
University, Xi’an 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center
(BEBC), Xi’an Jiaotong University, Xi’an 710049, People’s
Republic of China
| | - Min Lin
- MOE Key Laboratory of Biomedical Information
Engineering, School of Life Science and Technology, Xi’an Jiaotong
University, Xi’an 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center
(BEBC), Xi’an Jiaotong University, Xi’an 710049, People’s
Republic of China
| | - Guorui Jin
- MOE Key Laboratory of Biomedical Information
Engineering, School of Life Science and Technology, Xi’an Jiaotong
University, Xi’an 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center
(BEBC), Xi’an Jiaotong University, Xi’an 710049, People’s
Republic of China
| | - Tian Jian Lu
- Bioinspired Engineering and Biomechanics Center
(BEBC), Xi’an Jiaotong University, Xi’an 710049, People’s
Republic of China
- MOE Key Laboratory for Multifunctional Materials
and Structures, Xi’an Jiaotong University, Xi’an 710049,
People’s Republic of China
| | - Guy M. Genin
- MOE Key Laboratory of Biomedical Information
Engineering, School of Life Science and Technology, Xi’an Jiaotong
University, Xi’an 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center
(BEBC), Xi’an Jiaotong University, Xi’an 710049, People’s
Republic of China
- Department of Mechanical Engineering &
Materials Science, Washington University in St. Louis, St. Louis 63130, MO,
USA
- NSF Science and Technology Center for
Engineering MechanoBiology, Washington University in St. Louis, St. Louis 63130,
MO, USA
| | - Feng Xu
- MOE Key Laboratory of Biomedical Information
Engineering, School of Life Science and Technology, Xi’an Jiaotong
University, Xi’an 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center
(BEBC), Xi’an Jiaotong University, Xi’an 710049, People’s
Republic of China
| |
Collapse
|