1
|
Zhang Q, Pan RL, Wang H, Wang JJ, Lu SH, Zhang M. Nanoporous Titanium Implant Surface Accelerates Osteogenesis via the Piezo1/Acetyl-CoA/β-Catenin Pathway. NANO LETTERS 2024; 24:8257-8267. [PMID: 38920296 PMCID: PMC11247543 DOI: 10.1021/acs.nanolett.4c01101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 06/19/2024] [Accepted: 06/20/2024] [Indexed: 06/27/2024]
Abstract
Osseointegration is the most important factor determining implant success. The surface modification of TiO2 nanotubes prepared by anodic oxidation has remarkable advantages in promoting bone formation. However, the mechanism behind this phenomenon is still unintelligible. Here we show that the nanomorphology exhibited open and clean nanotube structure and strong hydrophilicity, and the nanomorphology significantly facilitated the adhesion, proliferation, and osteogenesis differentiation of stem cells. Exploring the mechanism, we found that the nanomorphology can enhance mitochondrial oxidative phosphorylation (OxPhos) by activating Piezo1 and increasing intracellular Ca2+. The increase in OxPhos can significantly uplift the level of acetyl-CoA in the cytoplasm but not significantly raise the level of acetyl-CoA in the nucleus, which was beneficial for the acetylation and stability of β-catenin and ultimately promoted osteogenesis. This study provides a new interpretation for the regulatory mechanism of stem cell osteogenesis by nanomorphology.
Collapse
Affiliation(s)
- Qian Zhang
- State
Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration
& National Clinical Research Center for Oral Diseases & Shaanxi
International Joint Research Center for Oral Diseases, Department
of General Dentistry and Emergency, School of Stomatology, Air Force Medical University, Xi’an 710032, China
| | - Run-Long Pan
- State
Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration
& National Clinical Research Center for Oral Diseases & Shaanxi
International Joint Research Center for Oral Diseases, Department
of General Dentistry and Emergency, School of Stomatology, Air Force Medical University, Xi’an 710032, China
| | - Hui Wang
- State
Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration
& National Clinical Research Center for Oral Diseases & Shaanxi
International Joint Research Center for Oral Diseases, Department
of General Dentistry and Emergency, School of Stomatology, Air Force Medical University, Xi’an 710032, China
| | - Jun-Jun Wang
- State
Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration
& National Clinical Research Center for Oral Diseases & Shaanxi
International Joint Research Center for Oral Diseases, Department
of General Dentistry and Emergency, School of Stomatology, Air Force Medical University, Xi’an 710032, China
| | - Song-He Lu
- Scientific
Research Department, Air Force Medical University, Xi’an 710032, China
| | - Min Zhang
- State
Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration
& National Clinical Research Center for Oral Diseases & Shaanxi
International Joint Research Center for Oral Diseases, Department
of General Dentistry and Emergency, School of Stomatology, Air Force Medical University, Xi’an 710032, China
| |
Collapse
|
2
|
Luptáková N, Dlouhý V, Sobola D, Fintová S, Weiser A, Beneš V, Dlouhý A. Interfaces between Cranial Bone and AISI 304 Steel after Long-Term Implantation: A Case Study of Cranial Screws. ACS Biomater Sci Eng 2024; 10:4297-4310. [PMID: 38900847 PMCID: PMC11234332 DOI: 10.1021/acsbiomaterials.4c00309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/22/2024]
Abstract
Interfaces between AISI 304 stainless steel screws and cranial bone were investigated after long-term implantation lasting for 42 years. Samples containing the interface regions were analyzed using state-of-the-art analytical techniques including secondary ion mass, Fourier-transform infrared, Raman, and X-ray photoelectron spectroscopies. Local samples for scanning transmission electron microscopy were cut from the interface regions using the focused ion beam technique. A chemical composition across the interface was recorded in length scales covering micrometric and nanometric resolutions and relevant differences were found between peri-implant and the distant cranial bone, indicating generally younger bone tissue in the peri-implant area. Furthermore, the energy dispersive spectroscopy revealed an 80 nm thick steel surface layer enriched by oxygen suggesting that the AISI 304 material undergoes a corrosion attack. The attack is associated with transport of metallic ions, namely, ferrous and ferric iron, into the bone layer adjacent to the implant. The results comply with an anticipated interplay between released iron ions and osteoclast proliferation. The interplay gives rise to an autocatalytic process in which the iron ions stimulate the osteoclast activity while a formation of fresh bone resorption sites boosts the corrosion process through interactions between acidic osteoclast extracellular compartments and the implant surface. The autocatalytic process thus may account for an accelerated turnover of the peri-implant bone.
Collapse
Affiliation(s)
- Natália Luptáková
- Institute of Physics of Materials, AS CR, v. v. i., Žižkova 513/22, Brno 61662, Czech Republic
| | - Václav Dlouhý
- Department of Neurosurgery, Second Faculty of Medicine, Charles University and University Hospital Motol, V Úvalu 84, Prague 150 06, Czech Republic
| | - Dinara Sobola
- Institute of Physics of Materials, AS CR, v. v. i., Žižkova 513/22, Brno 61662, Czech Republic
| | - Stanislava Fintová
- Institute of Physics of Materials, AS CR, v. v. i., Žižkova 513/22, Brno 61662, Czech Republic
| | - Adam Weiser
- Institute of Physics of Materials, AS CR, v. v. i., Žižkova 513/22, Brno 61662, Czech Republic
| | - Vladimír Beneš
- Department of Neurosurgery, Second Faculty of Medicine, Charles University and University Hospital Motol, V Úvalu 84, Prague 150 06, Czech Republic
| | - Antonín Dlouhý
- Institute of Physics of Materials, AS CR, v. v. i., Žižkova 513/22, Brno 61662, Czech Republic
| |
Collapse
|
3
|
DiCecco LA, Zhang J, Casagrande T, Grandfield K. New Avenues for Capturing Mineralization Events at Biomaterial Interfaces with Liquid-Transmission Electron Microscopy. NANO LETTERS 2024; 24:7821-7824. [PMID: 38913950 DOI: 10.1021/acs.nanolett.4c01525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/26/2024]
Abstract
Liquid-transmission electron microscopy (liquid-TEM) provides exciting potential for capturing mineralization events at biomaterial interfaces, though it is largely unexplored. To address this, we established a unique approach to visualize calcium phosphate (CaP)-titanium (Ti) interfacial mineralization events by combining the nanofabrication of Ti lamellae by focused ion beam with in situ liquid-TEM. Multiphasic CaP particles were observed to nucleate, adhere, and form different assemblies onto and adjacent to Ti lamellae. Here, we discuss new approaches for exploring the interaction between biomaterials and liquids at the nanoscale. Driving this technology is crucial for understanding and controlling biomineralization to improve implant osseointegration and direct new pathways for mineralized tissue disease treatment in the future.
Collapse
Affiliation(s)
- Liza-Anastasia DiCecco
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, L8S 4L8, Canada
- Department of Biomedical Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Jing Zhang
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, L8S 4L8, Canada
| | - Travis Casagrande
- Canadian Centre for Electron Microscopy, McMaster University, Hamilton, ON, L8S 4L8, Canada
| | - Kathryn Grandfield
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, L8S 4L8, Canada
- School of Biomedical Engineering, McMaster University, Hamilton, ON, L8S 4L8, Canada
| |
Collapse
|
4
|
Micheletti C, DiCecco LA, Deering J, Chen W, Ervolino da Silva AC, Shah FA, Palmquist A, Okamoto R, Grandfield K. Mesoscale characterization of osseointegration around an additively manufactured genistein-coated implant. Sci Rep 2024; 14:15339. [PMID: 38961115 PMCID: PMC11222380 DOI: 10.1038/s41598-024-66058-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Accepted: 06/26/2024] [Indexed: 07/05/2024] Open
Abstract
Given the hierarchical nature of bone and bone interfaces, osseointegration, namely the formation of a direct bone-implant contact, is best evaluated using a multiscale approach. However, a trade-off exists between field of view and spatial resolution, making it challenging to image large volumes with high resolution. In this study, we combine established electron microscopy techniques to probe bone-implant interfaces at the microscale and nanoscale with plasma focused ion beam-scanning electron microscopy (PFIB-SEM) tomography to evaluate osseointegration at the mesoscale. This characterization workflow is demonstrated for bone response to an additively manufactured Ti-6Al-4V implant which combines engineered porosity to facilitate bone ingrowth and surface functionalization via genistein, a phytoestrogen, to counteract bone loss in osteoporosis. SEM demonstrated new bone formation at the implant site, including in the internal implant pores. At the nanoscale, scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy confirmed the gradual nature of the bone-implant interface. By leveraging mesoscale analysis with PFIB-SEM tomography that captures large volumes of bone-implant interface with nearly nanoscale resolution, the presence of mineral ellipsoids varying in size and orientation was revealed. In addition, a well-developed lacuno-canalicular network and mineralization fronts directed both towards the implant and away from it were highlighted.
Collapse
Affiliation(s)
- Chiara Micheletti
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada.
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| | - Liza-Anastasia DiCecco
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada
| | - Joseph Deering
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada
| | - Wanqi Chen
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada
| | | | - Furqan A Shah
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Anders Palmquist
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Roberta Okamoto
- Department of Basic Sciences, Araçatuba Dental School, São Paulo State University, Araçatuba, SP, Brazil
- Research Productivity Scholarship (Process: 309408/2020-2), Araçatuba, SP, Brazil
| | - Kathryn Grandfield
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada.
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada.
- Brockhouse Institute for Materials Research, McMaster University, Hamilton, ON, Canada.
| |
Collapse
|
5
|
Chen Z, Wang B, Yang C, Lv Z, Wei Y, Pan T, Xuan F, Zhou X, Chen H, Shen H, Wang L, Zhang Y. 3D Printed Pedicle Screws with Microarc Oxidation Ceramic Interfaces Enhance Osteointegration and Orthopedic Fixation Feasibility. ACS APPLIED MATERIALS & INTERFACES 2024; 16:31983-31996. [PMID: 38865688 DOI: 10.1021/acsami.4c03628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2024]
Abstract
Effective osteointegration is of great importance for pedicle screws in spinal fusion surgeries. However, the lack of osteoinductive activity of current screws diminishes their feasibility for osteointegration and fixation, making screw loosening a common complication worldwide. In this study, Ti-6Al-4V pedicle screws with full through-hole design were fabricated via selective laser melting (SLM) 3D printing and then deposited with porous oxide coatings by microarc oxidation (MAO). The porous surface morphology of the oxide coating and the release of bioactive ions could effectively support cell adhesion, migration, vascularization, and osteogenesis in vitro. Furthermore, an in vivo goat model demonstrated the efficacy of modified screws in improving bone maturation and osseointegration, thus providing a promising method for feasible orthopedic internal fixation.
Collapse
Affiliation(s)
- Zehao Chen
- Department of Spine Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China
- Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Translational Research Institute of Brain and Brain-Like Intelligence, Department of Anesthesiology and Perioperative Medicine, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, Shanghai 200434, China
| | - Binghao Wang
- Guangxi Zhuang Autonomous Region Engineering Research Center for Biomaterials in Bone and Joint Degenerative Diseases, Guangxi Key Laboratory for Preclinical and Translational Research on Bone and Joint Degenerative Diseases, Affiliated Hospital of Youjiang Medical University, Baise, Guangxi 533000, China
- State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Chengliang Yang
- Guangxi Zhuang Autonomous Region Engineering Research Center for Biomaterials in Bone and Joint Degenerative Diseases, Guangxi Key Laboratory for Preclinical and Translational Research on Bone and Joint Degenerative Diseases, Affiliated Hospital of Youjiang Medical University, Baise, Guangxi 533000, China
| | - Zhendong Lv
- Department of Spine Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China
| | - Yu Wei
- Guangxi Zhuang Autonomous Region Engineering Research Center for Biomaterials in Bone and Joint Degenerative Diseases, Guangxi Key Laboratory for Preclinical and Translational Research on Bone and Joint Degenerative Diseases, Affiliated Hospital of Youjiang Medical University, Baise, Guangxi 533000, China
| | - Tianming Pan
- Danyang Hospital of Traditional Chinese Medicine, Jiangsu 212300, China
| | - Fuqing Xuan
- Department of Spine Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China
- School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China
| | - Xingdie Zhou
- Department of Spine Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China
- School of Materials Science and Engineering, Shanghai University, Shanghai 200444, China
| | - Hao Chen
- Department of Spine Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China
| | - Hongxing Shen
- Department of Spine Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China
| | - Liqiang Wang
- State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Yuhui Zhang
- Department of Spine Surgery, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China
| |
Collapse
|
6
|
Zamparini F, Gandolfi MG, Spinelli A, Ferri M, Iezzi G, Botticelli D, Prati C. Mineralization and morphology of peri-implant bone around loaded and unloaded dental implants retrieved from the human mandible. Oral Maxillofac Surg 2024; 28:623-637. [PMID: 37667130 PMCID: PMC11144681 DOI: 10.1007/s10006-023-01175-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Accepted: 08/12/2023] [Indexed: 09/06/2023]
Abstract
PURPOSE Limited data is reported regarding the bone mineralization around dental implants in the first months from insertion. The study analyzed the peri-implant bone around loaded and unloaded implants retrieved from human mandible after 4 months from placement. METHOD The composition and mineralization of human bone were analyzed through an innovative protocol technique using Environmental-Scanning-Electron-Microscopy connected with Energy-Dispersive-X-Ray-Spectroscopy (ESEM/EDX). Two regions of interest (ROIs, approximately 750×500 μm) for each bone implant sample were analyzed at the cortical (Cortical ROI) and apical (Apical ROI) implant threads. Calcium, phosphorus, and nitrogen (atomic%) were determined using EDX, and the specific ratios (Ca/N, P/N, and Ca/P) were calculated as mineralization indices. RESULTS Eighteen implant biopsies from ten patients were analyzed (unloaded implants, n=10; loaded implants, n=8). For each ROI, four bone areas (defined bones 1-4) were detected. These areas were characterized by different mineralization degree, varied Ca, P and N content, and different ratios, and by specific grayscale intensity detectable by ESEM images. Bony tissue in contact with loaded implants at the cortical ROI showed a higher percentage of low mineralized bone (bone 1) and a lower percentage of remodeling bone (bone 2) when compared to unloaded implants. The percentage of highly mineralized bone (bone 3) was similar in all groups. CONCLUSION Cortical and apical ROIs resulted in a puzzle of different bone "islands" characterized by various rates of mineralization. Only the loaded implants showed a high rate of mineralization in the cortical ROI.
Collapse
Affiliation(s)
- Fausto Zamparini
- Laboratory of Biomaterials and Oral Pathology, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40126, Bologna, Italy.
- Endodontic Clinical Section, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40126, Bologna, Italy.
| | - Maria Giovanna Gandolfi
- Laboratory of Biomaterials and Oral Pathology, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40126, Bologna, Italy
| | - Andrea Spinelli
- Endodontic Clinical Section, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40126, Bologna, Italy
| | - Mauro Ferri
- School of Dentistry, Corporación Universitária Rafael Núñez, 130001, Cartagena, de Indias, Colombia
| | - Giovanna Iezzi
- Department of Medical Oral and Biotechnological Sciences, University of Chieti/Pescara, 66013, Chieti, Italy
| | | | - Carlo Prati
- Endodontic Clinical Section, Department of Biomedical and Neuromotor Sciences, School of Dentistry, University of Bologna, 40126, Bologna, Italy
| |
Collapse
|
7
|
Cuahtecontzi Delint R, Jaffery H, Ishak MI, Nobbs AH, Su B, Dalby MJ. Mechanotransducive surfaces for enhanced cell osteogenesis, a review. BIOMATERIALS ADVANCES 2024; 160:213861. [PMID: 38663159 DOI: 10.1016/j.bioadv.2024.213861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 03/31/2024] [Accepted: 04/12/2024] [Indexed: 05/04/2024]
Abstract
Novel strategies employing mechano-transducing materials eliciting biological outcomes have recently emerged for controlling cellular behaviour. Targeted cellular responses are achieved by manipulating physical, chemical, or biochemical modification of material properties. Advances in techniques such as nanopatterning, chemical modification, biochemical molecule embedding, force-tuneable materials, and artificial extracellular matrices are helping understand cellular mechanotransduction. Collectively, these strategies manipulate cellular sensing and regulate signalling cascades including focal adhesions, YAP-TAZ transcription factors, and multiple osteogenic pathways. In this minireview, we are providing a summary of the influence that these materials, particularly titanium-based orthopaedic materials, have on cells. We also highlight recent complementary methodological developments including, but not limited to, the use of metabolomics for identification of active biomolecules that drive cellular differentiation.
Collapse
Affiliation(s)
- Rosalia Cuahtecontzi Delint
- Centre for the Cellular Microenvironment, Institute of Molecular, Cell and Systems Biology, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow G12 8QQ, UK.
| | - Hussain Jaffery
- Centre for the Cellular Microenvironment, Institute of Molecular, Cell and Systems Biology, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow G12 8QQ, UK
| | - Mohd I Ishak
- Bristol Dental School, University of Bristol, Lower Maudlin Street, Bristol BS1 2LY, UK
| | - Angela H Nobbs
- Bristol Dental School, University of Bristol, Lower Maudlin Street, Bristol BS1 2LY, UK
| | - Bo Su
- Bristol Dental School, University of Bristol, Lower Maudlin Street, Bristol BS1 2LY, UK
| | - Matthew J Dalby
- Centre for the Cellular Microenvironment, Institute of Molecular, Cell and Systems Biology, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow G12 8QQ, UK
| |
Collapse
|
8
|
Colabella L, Naili S, Le Cann S, Haiat G. Effect of collagen fibril orientation on the anisotropic properties of peri-implant bone. Biomech Model Mechanobiol 2024; 23:879-891. [PMID: 38300439 DOI: 10.1007/s10237-023-01811-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Accepted: 12/22/2023] [Indexed: 02/02/2024]
Abstract
In orthopedic and dental surgery, the implantation of biomaterials within the bone to restore the integrity of the treated organ has become a standard procedure. Their long-term stability relies on the osseointegration phenomena, where bone grows onto and around metallic implants, creating a bone-implant interface. Bone is a highly hierarchical material that evolves spatially and temporally during this healing phase. A deeper understanding of its biomechanical characteristics is needed, as they are determinants for surgical success. In this context, we propose a multiscale homogenization model to evaluate the effective elastic properties of bone as a function of the distance from the implant, based on the tissue's structure and composition at lower scales. The model considers three scales: hydroxyapatite foam (nanoscale), ultrastructure (microscale), and tissue (mesoscale). The elastic properties and the volume fraction of the elementary constituents of bone matrix (mineral, collagen, and water), the orientation of the collagen fibril relative to the implant surface, and the mesoscale porosity constitute the input data of the model. The effect of a spatiotemporal variation in the collagen fibrils' orientation on the bone anisotropic properties in the proximity of the implant was investigated. The findings revealed a strong variation of the components of the effective elasticity tensor of the bone as a function of the distance from the implant. The effective elasticity appears to be primarily sensitive to the porosity (mesoscale) rather than to the collagen fibrils' orientation (sub-micro scale). However, the orientation of the fibrils has a significant influence on the isotropy of the bone. When analyzing the symmetry properties of the effective elasticity tensor, the ratio between the isotropic and hexagonal components is determined by a combination of the porosity and the fibrils' orientation. A decrease in porosity leads to a decrease in bone isotropy and, in turn, an increase in the impact of the fibrils' orientation. These results demonstrate that the collagen fibril orientation should be taken into account to properly describe the effective elastic anisotropy of bone at the organ scale.
Collapse
Affiliation(s)
- Lucas Colabella
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, F-94010, Creteil, France
- INTEMA, CONICET, Av. Cristóbal Colón 10850, B7606BWV, Mar del Plata, Argentina
| | - Salah Naili
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010, Creteil, France
| | - Sophie Le Cann
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, F-94010, Creteil, France
| | - Guillaume Haiat
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, F-94010, Creteil, France.
| |
Collapse
|
9
|
Li M, Fan Y, Ran M, Chen H, Han J, Zhai J, Wang Z, Ning C, Shi Z, Yu P. Hydrogel Coatings of Implants for Pathological Bone Repair. Adv Healthc Mater 2024:e2401296. [PMID: 38794971 DOI: 10.1002/adhm.202401296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2024] [Revised: 05/14/2024] [Indexed: 05/27/2024]
Abstract
Hydrogels are well-suited for biomedical applications due to their numerous advantages, such as excellent bioactivity, versatile physical and chemical properties, and effective drug delivery capabilities. Recently, hydrogel coatings have developed to functionalize bone implants which are biologically inert and cannot withstand the complex bone tissue repair microenvironment. These coatings have shown promise in addressing unique and pressing medical needs. This review begins with the major functionalized performance and interfacial bonding strategy of hydrogel coatings, with a focus on the novel external field response properties of the hydrogel. Recent advances in the fabrication strategies of hydrogel coatings and their use in the treatment of pathologic bone regeneration are highlighted. Finally, challenges and emerging trends in the evolution and application of physiological environment-responsive and external electric field-responsive hydrogel coatings for bone implants are discussed.
Collapse
Affiliation(s)
- Mengqing Li
- School of Materials Science and Engineering, GuangDong Engineering Technology Research Center of Metallic Materials Surface Functionalization, National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Medical Devices Research and Testing Center, South China University of Technology, Guangzhou 510641, Guangzhou, 510006, China
| | - Youzhun Fan
- School of Materials Science and Engineering, GuangDong Engineering Technology Research Center of Metallic Materials Surface Functionalization, National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Medical Devices Research and Testing Center, South China University of Technology, Guangzhou 510641, Guangzhou, 510006, China
| | - Maofei Ran
- School of Materials Science and Engineering, GuangDong Engineering Technology Research Center of Metallic Materials Surface Functionalization, National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Medical Devices Research and Testing Center, South China University of Technology, Guangzhou 510641, Guangzhou, 510006, China
| | - Haoyan Chen
- School of Materials Science and Engineering, GuangDong Engineering Technology Research Center of Metallic Materials Surface Functionalization, National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Medical Devices Research and Testing Center, South China University of Technology, Guangzhou 510641, Guangzhou, 510006, China
| | - Jien Han
- School of Materials Science and Engineering, GuangDong Engineering Technology Research Center of Metallic Materials Surface Functionalization, National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Medical Devices Research and Testing Center, South China University of Technology, Guangzhou 510641, Guangzhou, 510006, China
| | - Jinxia Zhai
- School of Materials Science and Engineering, GuangDong Engineering Technology Research Center of Metallic Materials Surface Functionalization, National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Medical Devices Research and Testing Center, South China University of Technology, Guangzhou 510641, Guangzhou, 510006, China
| | - Zhengao Wang
- School of Materials Science and Engineering, GuangDong Engineering Technology Research Center of Metallic Materials Surface Functionalization, National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Medical Devices Research and Testing Center, South China University of Technology, Guangzhou 510641, Guangzhou, 510006, China
| | - Chengyun Ning
- School of Materials Science and Engineering, GuangDong Engineering Technology Research Center of Metallic Materials Surface Functionalization, National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Medical Devices Research and Testing Center, South China University of Technology, Guangzhou 510641, Guangzhou, 510006, China
| | - Zhifeng Shi
- School of Materials Science and Engineering, GuangDong Engineering Technology Research Center of Metallic Materials Surface Functionalization, National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Medical Devices Research and Testing Center, South China University of Technology, Guangzhou 510641, Guangzhou, 510006, China
| | - Peng Yu
- School of Materials Science and Engineering, GuangDong Engineering Technology Research Center of Metallic Materials Surface Functionalization, National Engineering Research Center for Tissue Restoration and Reconstruction, South China University of Technology, Medical Devices Research and Testing Center, South China University of Technology, Guangzhou 510641, Guangzhou, 510006, China
| |
Collapse
|
10
|
Aboona F, Bou-Akl T, Miller AJ, Fry M, Wu B, Pawlitz P, Ren W, Markel DC. Effects of Vancomycin/Tobramycin-Doped Ceramic Composite (Polyvinyl Alcohol Composite-Vancomycin/Tobramycin-Polymeric Dicalcium Phosphate Dihydrate) in a Rat Femur Model Implanted With Contaminated Porous Titanium Cylinders. J Arthroplasty 2024:S0883-5403(24)00424-8. [PMID: 38718912 DOI: 10.1016/j.arth.2024.04.076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 04/26/2024] [Accepted: 04/27/2024] [Indexed: 06/06/2024] Open
Abstract
BACKGROUND Periprosthetic joint infection (PJI) remains common and problematic. We hypothesized that using a bioceramic that provided rapid release of the antibiotics (vancomycin [VAN] or VAN and tobramycin [VAN and TOB]) from a polyvinyl-alcohol-composite (PVA) combined with a delayed and sustained antibiotic release from polymeric-dicalcium-phosphate-dihydrate (PDCPD) ceramic would inhibit S. aureus-associated implant infections. METHODS A total of 50 male Sprague Dawley rats were randomly divided into 5 groups-I: negative control; II: bacteria only; III: bacteria + saline wash; IV: bacteria + PVA-VAN-PDCPD, and V: bacteria + PVA-VAN-TOB-PDCPD. A porous titanium (Ti) implant was press-fit into the rat knee. S. aureus-containing broth was added into the joint space creating a PJI. After 1 week, the joints from groups III to V were washed with saline and the fluid collected for bacterial quantification. This was followed by saline irrigation treatment (groups III to V) and application of the antibiotic-loaded PVA-PDCPD bioceramic (groups IV and V). On day 21, joint fluid was collected, and the implants harvested for bacterial quantification. RESULTS No bacteria were isolated from the negative control (group I). The positive control (group II) was positive on both days 7 and 21. Bacteria were still present on day 21 in the fluid and implant in group III. Groups (IV and V) showed a decrease in the bacterial burden in the fluid and implant on day 21. There were significant differences in bacteria levels in the collected wash fluid and on the implant at day 21 between the saline wash (group III) and treatment groups (IV and V). CONCLUSIONS In this animal model of acute periprosthetic infection, treatment with PVA-VAN-PDCPD and PVA-VAN/TOB-PDCPD reduced bacterial load in the infected joint and the infected Ti implant. Application of PVA-VAN-PDCPD and/or PVA-VAN/TOB-PDCPD after saline irrigation could be used as an addition to the treatment of PJI.
Collapse
Affiliation(s)
- Fadi Aboona
- Section of Orthopaedic Surgery, Ascension-Providence Hospital, Southfield, Michigan
| | - Therese Bou-Akl
- Section of Orthopaedic Surgery, Ascension-Providence Hospital, Southfield, Michigan
| | - Adam J Miller
- Section of Orthopaedic Surgery, Ascension-Providence Hospital, Southfield, Michigan
| | - Mike Fry
- Section of Orthopaedic Surgery, Ascension-Providence Hospital, Southfield, Michigan
| | - Bin Wu
- Section of Orthopaedic Surgery, Ascension-Providence Hospital, Southfield, Michigan
| | - Paula Pawlitz
- Section of Orthopaedic Surgery, Ascension-Providence Hospital, Southfield, Michigan
| | - Weiping Ren
- Section of Orthopaedic Surgery, Ascension-Providence Hospital, Southfield, Michigan; Virotech Co., Inc., Troy, Michigan
| | - David C Markel
- Section of Orthopaedic Surgery, Ascension-Providence Hospital, Southfield, Michigan; The Core Institute, Novi, Michigan
| |
Collapse
|
11
|
Hindurao B, Gujare A, Jadhav H, Dhatrak P. Evaluate the effect of bone density variation on stress distribution at the bone-implant interface using numerical analysis. Proc Inst Mech Eng H 2024; 238:463-470. [PMID: 38534009 DOI: 10.1177/09544119241240940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/28/2024]
Abstract
The current study aims to comprehend how different bone densities affect stress distribution at the bone-implant interface. This will help understand the behaviour and help predict success rates of the implant planted in different bone densities. The process of implantation involves the removal of bone from a small portion of the jawbone to replace either a lost tooth or an infected one and an implant is inserted in the cavity made as a result. Now the extent of fixation due to osseointegration is largely dependent on the condition of the bone in terms of the density. Generally, the density of the bone is classified into four categories namely D1, D2, D3, and D4; with D1 being purely cortical and D4 having higher percentage of cancellous bordered by cortical bone. A bone model with a form closely resembling the actual bone was made using 3D CAD software and was meshed using Hyper Mesh. The model was subjected to an oblique load of 120 N at 70° to the vertical to replicate occlusal loading. A finite element static analysis was done using Abaqus software. The stress distribution contours at the bone-implant contact zone were studied closely to understand the changes as a result of the varying density. It was revealed that as the quantity of the cancellous bone increased from D1 to D4 the cortical peak stress levels dropped. The bone density and the corresponding change in the material characteristics was also responsible for the variation in the peak stress and displacement values.
Collapse
Affiliation(s)
- Bhargav Hindurao
- Department of Mechanical Engineering, Dr Vishwanath Karad MIT World Peace University, Pune, Maharashtra, India
| | - Aditya Gujare
- Department of Mechanical Engineering, Dr Vishwanath Karad MIT World Peace University, Pune, Maharashtra, India
| | - Harshavardhan Jadhav
- Department of Mechanical Engineering, Dr Vishwanath Karad MIT World Peace University, Pune, Maharashtra, India
| | - Pankaj Dhatrak
- Department of Mechanical Engineering, Dr Vishwanath Karad MIT World Peace University, Pune, Maharashtra, India
| |
Collapse
|
12
|
Sun G, Shu T, Ma S, Li M, Qu Z, Li A. A submicron forest-like silicon surface promotes bone regeneration by regulating macrophage polarization. Front Bioeng Biotechnol 2024; 12:1356158. [PMID: 38707505 PMCID: PMC11066256 DOI: 10.3389/fbioe.2024.1356158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 03/14/2024] [Indexed: 05/07/2024] Open
Abstract
Introduction: Silicon is a major trace element in humans and a prospective supporting biomaterial to bone regeneration. Submicron silicon pillars, as a representative surface topography of silicon-based biomaterials, can regulate macrophage and osteoblastic cell responses. However, the design of submicron silicon pillars for promoting bone regeneration still needs to be optimized. In this study, we proposed a submicron forest-like (Fore) silicon surface (Fore) based on photoetching. The smooth (Smo) silicon surface and photoetched regular (Regu) silicon pillar surface were used for comparison in the bone regeneration evaluation. Methods: Surface parameters were investigated using a field emission scanning electron microscope, atomic force microscope, and contact angle instrument. The regulatory effect of macrophage polarization and succedent osteogenesis was studied using Raw264.7, MC3T3-E1, and rBMSCs. Finally, a mouse calvarial defect model was used for evaluating the promoting effect of bone regeneration on the three surfaces. Results: The results showed that the Fore surface can increase the expression of M2-polarized markers (CD163 and CD206) and decrease the expression of inflammatory cytokines, including interleukin-6 (IL-6) and tumor necrosis factor alpha (TNF-α). Fore surface can promote the osteogenesis in MC3T3-E1 cells and osteoblastic differentiation of rBMSCs. Furthermore, the volume fraction of new bone and the thickness of trabeculae on the Fore surface were significantly increased, and the expression of RANKL was downregulated. In summary, the upregulation of macrophage M2 polarization on the Fore surface contributed to enhanced osteogenesis in vitro and accelerated bone regeneration in vivo. Discussion: This study strengthens our understanding of the topographic design for developing future silicon-based biomaterials.
Collapse
Affiliation(s)
- Guo Sun
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, China
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Tianyu Shu
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, China
| | - Shaoyang Ma
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, China
| | - Meng Li
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, China
| | - Zhiguo Qu
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Ang Li
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, China
| |
Collapse
|
13
|
Hall TAG, Theodoridis K, Kohli N, Cegla F, van Arkel RJ. Active osseointegration in an ex vivo porcine bone model. Front Bioeng Biotechnol 2024; 12:1360669. [PMID: 38585711 PMCID: PMC10995341 DOI: 10.3389/fbioe.2024.1360669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Accepted: 03/08/2024] [Indexed: 04/09/2024] Open
Abstract
Achieving osseointegration is a fundamental requirement for many orthopaedic, oral, and craniofacial implants. Osseointegration typically takes three to 6 months, during which time implants are at risk of loosening. The aim of this study was to investigate whether osseointegration could be actively enhanced by delivering controllable electromechanical stimuli to the periprosthetic bone. First, the osteoconductivity of the implant surface was confirmed using an in vitro culture with murine preosteoblasts. The effects of active treatment on osseointegration were then investigated in a 21-day ex vivo model with freshly harvested cancellous bone cylinders (n = 24; Ø10 mm × 5 mm) from distal porcine femora, with comparisons to specimens treated by a distant ultrasound source and static controls. Cell viability, proliferation and distribution was evident throughout culture. Superior ongrowth of tissue onto the titanium discs during culture was observed in the actively stimulated specimens, with evidence of ten-times increased mineralisation after 7 and 14 days of culture (p < 0.05) and 2.5 times increased expression of osteopontin (p < 0.005), an adhesive protein, at 21 days. Moreover, histological analyses revealed increased bone remodelling at the implant-bone interface in the actively stimulated specimens compared to the passive controls. Active osseointegration is an exciting new approach for accelerating bone growth into and around implants.
Collapse
Affiliation(s)
- Thomas A G Hall
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | - Konstantinos Theodoridis
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | - Nupur Kohli
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | - Frederic Cegla
- Non-Destructive Evaluation Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | - Richard J van Arkel
- Biomechanics Group, Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| |
Collapse
|
14
|
Chang Y, Kong K, Tong Z, Qiao H, Jin M, Wu X, Ouyang Z, Zhang J, Zhai Z, Li H. TiO2 nanotube topography enhances osteogenesis through filamentous actin and XB130-protein-mediated mechanotransduction. Acta Biomater 2024; 177:525-537. [PMID: 38360291 DOI: 10.1016/j.actbio.2024.02.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 01/09/2024] [Accepted: 02/08/2024] [Indexed: 02/17/2024]
Abstract
TiO2 nanotube topography, as nanomechanical stimulation, can significantly promote osteogenesis and improve the osteointegration on the interface of implants and bone tissue. However, the underlying mechanism has not been fully elucidated. XB130 is a member of the actin filament-associated protein family and is involved in the regulation of cytoskeleton and tyrosine kinase-mediated signalling as an adaptor protein. Whether XB130 is involved in TiO2 nanotubes-induced osteogenic differentiation and how it functions in mechano-biochemical signalling transduction remain to be elucidated. In this study, the role of XB130 on TiO2 nanotube-induced osteogenesis and mechanotransduction was systematically investigated. TiO2 nanotube topography was fabricated via anodic oxidation and characterized. The osteogenic effect was significantly accelerated by the TiO2 nanotube surface in vitro and vivo. XB130 was significantly upregulated during this process. Moreover, XB130 overexpression significantly promoted osteogenic differentiation, whereas its knockdown inhibited it. Filamentous actin depolymerization could change the expression and distribution of XB130, thus affecting osteogenic differentiation. Mechanistically, XB130 could interact with Src and result in the activation of the downstream PI3K/Akt/GSK-3β/β-catenin pathway, which accounts for the regulation of osteogenesis. This study for the first time showed that the enhanced osteogenic effect of TiO2 nanotubes could be partly due to the filamentous actin and XB130 mediated mechano-biochemical signalling transduction, which might provide a reference for guiding the design and modification of prostheses to promote bone regeneration and osseointegration. STATEMENT OF SIGNIFICANCE: TiO2 nanotubes topography can regulate cytoskeletal rearrangement and thus promote osteogenic differentiation of BMSCs. However, how filamentous actin converts mechanical stimulus into biochemical activity remains unclear. XB130 is a member of actin filament-associated protein family and involves in the regulation of tyrosine kinase-mediated signalling. Therefore, we hypothesised that XB130 might bridge the mechano-biochemical signalling transduction during TiO2 nanotubes-induced osteogenic differentiation. For the first time, this study shows that TiO2 nanotubes enhance osteogenesis through filamentous actin and XB130 mediated mechanotransduction, which provides new theoretical basis for guiding the design and modification of prostheses to promote bone regeneration and osseointegration.
Collapse
Affiliation(s)
- Yongyun Chang
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 200011, Shanghai, China
| | - Keyu Kong
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 200011, Shanghai, China
| | - Zhicheng Tong
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 200011, Shanghai, China
| | - Hua Qiao
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 200011, Shanghai, China
| | - Minghao Jin
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 200011, Shanghai, China
| | - Xinru Wu
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 200011, Shanghai, China
| | - Zhengxiao Ouyang
- Department of Orthopaedics, The Second Xiangya Hospital, Central South University, 410011, Changsha, Hunan, China
| | - Jingwei Zhang
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 200011, Shanghai, China
| | - Zanjing Zhai
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 200011, Shanghai, China.
| | - Huiwu Li
- Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedics, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 200011, Shanghai, China.
| |
Collapse
|
15
|
Budde S, Derksen A, Hurschler C, Fennema P, Windhagen H, Plagge J, Flörkemeier T, von Lewinski G, Noll Y, Schwarze M. Very early migration of a calcar-guided short stem: a randomized study of early mobilization and the influence of a calcium phosphate coating with 60 patients. Sci Rep 2024; 14:3837. [PMID: 38360840 PMCID: PMC10869691 DOI: 10.1038/s41598-023-50829-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 12/26/2023] [Indexed: 02/17/2024] Open
Abstract
This study analyzed the migration of a calcar-guided short stem to determine the course of very early migration, as well as evaluated the effect of an additional calcium phosphate (CP) coating on a titanium plasma spray (TPS) coating, which has not been analyzed previously. Sixty patients were enrolled in this study and were treated with the A2 calcar-guided short stem. The implant coating was randomized with either the TPS or an additional CP coating, and radiostereometric analysis was performed with the baseline measurement before initial weight-bearing, along with follow-up examinations at 1 week, 6 weeks, 3 months, and 6 months. Implant migrations were 0.27 mm (standard deviation [SD], 0.13 mm) and 0.74 mm (SD, 1.11 mm) at 1 week and 6 months post-surgery, respectively, and 65% and 87% of the implants reached their final position 1 week and 6 weeks after surgery, respectively. After 6 weeks, 3 months, and 6 months, a significant increase was noted in the migration of the CP coating group vs. that of the TPS coating group. Upon the final observation at 6 months, the groups displayed on average a 0.74-mm migration. Most of the analyzed implants ceased migration within the first week post-surgery, but the CP coating demonstrated a higher and more prolonged migration compared to the TPS coating.
Collapse
Affiliation(s)
- Stefan Budde
- Hannover Medical School, Department of Orthopaedic Surgery, Diakovere Annastift, Anna Von Borries Str. 1-6, 30625, Hannover, Germany
- Evangelisches Klinikum Bethel, Universitätsklinikum OWL der Universität Bielefeld, Burgsteig 13, 33617, Bielefeld, Germany
| | - Alexander Derksen
- Hannover Medical School, Department of Orthopaedic Surgery, Diakovere Annastift, Anna Von Borries Str. 1-6, 30625, Hannover, Germany
| | - Christof Hurschler
- Hannover Medical School, Department of Orthopaedic Surgery, Diakovere Annastift, Anna Von Borries Str. 1-6, 30625, Hannover, Germany
| | - Peter Fennema
- AMR Advanced Medical Research, Männedorf, Switzerland
| | - Henning Windhagen
- Hannover Medical School, Department of Orthopaedic Surgery, Diakovere Annastift, Anna Von Borries Str. 1-6, 30625, Hannover, Germany
| | - Jochen Plagge
- Hannover Medical School, Department of Orthopaedic Surgery, Diakovere Annastift, Anna Von Borries Str. 1-6, 30625, Hannover, Germany
| | - Thilo Flörkemeier
- Hannover Medical School, Department of Orthopaedic Surgery, Diakovere Annastift, Anna Von Borries Str. 1-6, 30625, Hannover, Germany
| | - Gabriela von Lewinski
- Hannover Medical School, Department of Orthopaedic Surgery, Diakovere Annastift, Anna Von Borries Str. 1-6, 30625, Hannover, Germany
| | - Yvonne Noll
- Hannover Medical School, Department of Orthopaedic Surgery, Diakovere Annastift, Anna Von Borries Str. 1-6, 30625, Hannover, Germany
| | - Michael Schwarze
- Hannover Medical School, Department of Orthopaedic Surgery, Diakovere Annastift, Anna Von Borries Str. 1-6, 30625, Hannover, Germany.
- Department for Medical Technology, Hochschule Bremerhaven, An Der Karlstraße 8, 27568, Bremerhaven, Germany.
| |
Collapse
|
16
|
Mishra D, Basu B. Biomechanical analysis of peri-prosthetic bone response to hybrid threaded zirconia dental implants: An in silico model. J Mech Behav Biomed Mater 2024; 150:106310. [PMID: 38128471 DOI: 10.1016/j.jmbbm.2023.106310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 11/29/2023] [Accepted: 12/03/2023] [Indexed: 12/23/2023]
Abstract
The biomechanical response of mandibular bone determines primary stability and concomitant osseointegration of dental implants. This study explores the impact of nature of loading and bone conditions on biomechanical response of hybrid threaded single-piece zirconia dental implants. To develop such understanding, three implants (SQ_V, V_BUT, and V_V), with different combinations of threads, square (SQ), buttress (BUT), and triangular (V), have been investigated. Finite Element Analysis (FEA) was carried out to simulate implantation at the molar position of mandible of varying densities under axial (≤500 N) and oblique (118.2 N) loadings. Patient-specific bone conditions (for a wider population) were considered by scaling the density and the elastic modulus of mandible to represent, 'weak', 'healthy', and 'strong' bone conditions. FEA results revealed that SQ_V and V_BUT implants exhibited a better biomechanical response without significant variation (<0.5%) in von Mises stress, regardless of bone density and axial loadings. These implants are predicted to perform with clinically acceptable factor of safety under investigated implantation scenarios, whereas V_BUT implant showed a larger variation (∼±12%). FEA simulation with oblique loading further validated such results. The 'weak' bone conditions resulted in maximum peri-implant microstrain, whereas 'strong and healthy' bone exhibited values close to the permissible range of physiological remodeling. The maximum micromotion (∼12.3 ± 6.2 μm for 'weak' bone) at bone-implant interface suggested that implant loosening and impaired osseointegration will not occur in any of selected virtual implantation cases. Both SQ_V and V_BUT implants will be considered further in implant development, involving manufacturing and product prototype validation. Taken together, the critical analysis of FEA results indicates a significant impact of bone density and distinct combinations of external threads on the biomechanical responses, in both the implant and the surrounding bone.
Collapse
Affiliation(s)
- Deepa Mishra
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bengaluru, 560012, India
| | - Bikramjit Basu
- Laboratory for Biomaterials, Materials Research Centre, Indian Institute of Science, Bengaluru, 560012, India; Centre for Biosystems Science and Engineering, Indian Institute of Science, Bangalore, 560012, India.
| |
Collapse
|
17
|
Shu T, Wang X, Li M, Ma S, Cao J, Sun G, Lai T, Liu S, Li A, Qu Z, Pei D. Nanoscaled Titanium Oxide Layer Provokes Quick Osseointegration on 3D-Printed Dental Implants: A Domino Effect Induced by Hydrophilic Surface. ACS NANO 2024; 18:783-797. [PMID: 38117950 DOI: 10.1021/acsnano.3c09285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2023]
Abstract
Three-dimensional printing is a revolutionary strategy to fabricate dental implants. Especially, 3D-printed dental implants modified with nanoscaled titanium oxide layer (H-SLM) have impressively shown quick osseointegration, but the accurate mechanism remains elusive. Herein, we unmask a domino effect that the hydrophilic surface of the H-SLM facilitates blood wetting, enhances the blood shear rate, promotes blood clotting, and changes clot features for quick osseointegration. Combining computational fluid dynamic simulation and biological verification, we find a blood shear rate during blood wetting of the hydrophilic H-SLM 1.2-fold higher than that of the raw 3D-printed implant, which activates blood clot formation. Blood clots formed on the hydrophilic H-SLM demonstrate anti-inflammatory and pro-osteogenesis effects, leading to a 1.5-fold higher bone-to-implant contact and a 1.8-fold higher mechanical anchorage at the early stage of osseointegration. This mechanism deepens current knowledge between osseointegration speed and implant surface characteristics, which is instructive in surface nanoscaled modification of multiple 3D-printed intrabony implants.
Collapse
Affiliation(s)
- Tianyu Shu
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xueliang Wang
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Meng Li
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Shaoyang Ma
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Jiao Cao
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Guo Sun
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Tao Lai
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Shaobao Liu
- State Key Laboratory of Mechanics and Control for Aerospace Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Ang Li
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Zhiguo Qu
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Dandan Pei
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| |
Collapse
|
18
|
Pius AK, Toya M, Gao Q, Ergul YS, Chow SKH, Goodman SB. Effects of Aging on Osteosynthesis at Bone-Implant Interfaces. Biomolecules 2023; 14:52. [PMID: 38254652 PMCID: PMC10813487 DOI: 10.3390/biom14010052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 12/23/2023] [Accepted: 12/27/2023] [Indexed: 01/24/2024] Open
Abstract
Joint replacement is a common surgery and is predominantly utilized for treatment of osteoarthritis in the aging population. The longevity of many of these implants depends on bony ingrowth. Here, we provide an overview of current techniques in osteogenesis (inducing bone growth onto an implant), which is affected by aging and inflammation. In this review we cover the biologic underpinnings of these processes as well as the clinical applications. Overall, aging has a significant effect at the cellular and macroscopic level that impacts osteosynthesis at bone-metal interfaces after joint arthroplasty; potential solutions include targeting prolonged inflammation, preventing microbial adhesion, and enhancing osteoinductive and osteoconductive properties.
Collapse
Affiliation(s)
- Alexa K. Pius
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, Stanford, CA 94063, USA (Y.S.E.)
| | - Masakazu Toya
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, Stanford, CA 94063, USA (Y.S.E.)
| | - Qi Gao
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, Stanford, CA 94063, USA (Y.S.E.)
| | - Yasemin Sude Ergul
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, Stanford, CA 94063, USA (Y.S.E.)
| | - Simon Kwoon-Ho Chow
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, Stanford, CA 94063, USA (Y.S.E.)
| | - Stuart Barry Goodman
- Department of Orthopaedic Surgery, School of Medicine, Stanford University, Stanford, CA 94063, USA (Y.S.E.)
- Department of Bioengineering, Stanford University, Stanford, CA 94305, USA
| |
Collapse
|
19
|
Wang M, Wang Y, Meng Y, Pan C. Functionally graded stem optimizes the fixed and sliding surface coupling mechanism. Comput Methods Biomech Biomed Engin 2023:1-13. [PMID: 38108146 DOI: 10.1080/10255842.2023.2293654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Accepted: 12/05/2023] [Indexed: 12/19/2023]
Abstract
Whether the optimization of fixed surface and sliding surface coupling mechanism is related to the hierarchical level of functionally graded porous stem is unknown. The functionally graded porous finite element stem models were constructed using tetrahedral microstructure with the porosities of 47-95%. The stress distribution for femoral bone gradually strengthened, the stress shielding was decreased along the increase of hierarchical levels of the stem after implantation. The coupling mechanism of fixed and sliding surfaces can be optimized by the functional gradient porous stem, the performance advantages become more prominent with the increase of hierarchical levels of the structure.
Collapse
Affiliation(s)
- Mincong Wang
- Department of Orthopaedic Surgery, The Fifth Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China
| | - Yuzhu Wang
- Department of Orthopaedic Surgery, Zhongshan Hospital of Traditional Chinese Medicine Affiliated to Guangzhou University of Traditional Chinese Medicine, Zhongshan, Guangdong, China
| | - Yue Meng
- Department of Orthopaedic Surgery, The Fifth Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China
| | - Chenglong Pan
- Department of Orthopaedic Surgery, The Fifth Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, China
| |
Collapse
|
20
|
Šugár P, Antala R, Šugárová J, Kováčik J, Pata V. Study on Surface Roughness, Morphology, and Wettability of Laser-Modified Powder Metallurgy-Processed Ti-Graphite Composite Intended for Dental Application. Bioengineering (Basel) 2023; 10:1406. [PMID: 38135997 PMCID: PMC10740645 DOI: 10.3390/bioengineering10121406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 12/05/2023] [Accepted: 12/07/2023] [Indexed: 12/24/2023] Open
Abstract
In this study, the surface laser treatment of a new type of dental biomaterial, a Ti-graphite composite, prepared by low-temperature powder metallurgy, was investigated. Different levels of output laser power and the scanning speed of the fiber nanosecond laser with a wavelength of 1064 nm and argon as a shielding gas were used in this experiment. The surface integrity of the machined surfaces was evaluated to identify the potential for the dental implant's early osseointegration process, including surface roughness parameter documentation by contact and non-contact methods, surface morphology assessment by scanning electron microscopy, and surface wettability estimation using the sessile drop technique. The obtained results showed that the surface roughness parameters attributed to high osseointegration relevance (Rsk, Rku, and Rsm) were not significantly influenced by laser power, and on the other hand, the scanning speed seems to have the most prevalent effect on surface roughness when exhibiting statistical differences in all evaluated profile roughness parameters except Rvk. The obtained laser-modified surfaces were hydrophilic, with a contact angle in the range of 62.3° to 83.2°.
Collapse
Affiliation(s)
- Peter Šugár
- Institute of Production Technologies, Faculty of Materials Science and Technology, Slovak University of Technology, J. Bottu 25, 917 24 Trnava, Slovakia; (R.A.); (J.Š.)
| | - Richard Antala
- Institute of Production Technologies, Faculty of Materials Science and Technology, Slovak University of Technology, J. Bottu 25, 917 24 Trnava, Slovakia; (R.A.); (J.Š.)
| | - Jana Šugárová
- Institute of Production Technologies, Faculty of Materials Science and Technology, Slovak University of Technology, J. Bottu 25, 917 24 Trnava, Slovakia; (R.A.); (J.Š.)
| | - Jaroslav Kováčik
- Slovak Academy of Sciences, Institute of Materials and Machine Mechanics, Dúbravská cesta 9, 845 13 Bratislava, Slovakia;
| | - Vladimír Pata
- Department of Production Engineering, Faculty of Technology, Tomas Bata University, Vavrečkova 5669, 960 01 Zlín, Czech Republic;
| |
Collapse
|
21
|
Zhang C, Hayashi K, Ishikawa K. Osseointegration enhancement by controlling dispersion state of carbonate apatite in polylactic acid implant. Colloids Surf B Biointerfaces 2023; 232:113588. [PMID: 37844475 DOI: 10.1016/j.colsurfb.2023.113588] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 10/07/2023] [Accepted: 10/10/2023] [Indexed: 10/18/2023]
Abstract
Osteoconductive ceramics (OCs) are often used to endow polylactic acid (PLA) with osseointegration ability. Conventionally, OC powder is dispersed in PLA. However, considering cell attachment to the implant, OCs may be more favorable when they exist in the form of aggregations, such as granules, and are larger than the cells rather than being dispersed like a powder. In this study, to clarify the effects of the dispersion state of OCs on the osseointegration ability, carbonate apatite (CAp), a bone mineral analog that is osteoconductive and bioresorbable, powder-PLA (P-PLA), and CAp granule-PLA (G-PLA) composite implants were fabricated via thermal pressing. The powder and granule sizes of CAp were approximately 1 and 300-600 µm, respectively. G-PLA exhibited a higher water wettability and released calcium and phosphate ions faster than P-PLA. When cylindrical G-PLA, P-PLA, and PLA were implanted in rabbit tibial bone defects, G-PLA promoted bone maturation compared to P-PLA and pure PLA. Furthermore, G-PLA bonded directly to the host bone, whereas P-PLA bonded across the osteoid layers. Consequently, the bone-to-implant contact of G-PLA was 1.8- and 5.6-fold higher than those of P-PLA and PLA, respectively. Furthermore, the adhesive shear strength of G-PLA was 1.9- and 3.0-fold higher than those of P-PLA and PLA, respectively. Thus, G-PLA achieved earlier and stronger osseointegration than P-PLA or PLA. The findings of this study highlight the significance of the state of dispersion of OCs in implants as a novel strategy for material development.
Collapse
Affiliation(s)
- Cheng Zhang
- Department of Biomaterials Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Koichiro Hayashi
- Department of Biomaterials Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
| | - Kunio Ishikawa
- Department of Biomaterials Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| |
Collapse
|
22
|
Kechagias S, Theodoridis K, Broomfield J, Malpartida-Cardenas K, Reid R, Georgiou P, van Arkel RJ, Jeffers JRT. The effect of nodal connectivity and strut density within stochastic titanium scaffolds on osteogenesis. Front Bioeng Biotechnol 2023; 11:1305936. [PMID: 38107615 PMCID: PMC10721980 DOI: 10.3389/fbioe.2023.1305936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Accepted: 11/20/2023] [Indexed: 12/19/2023] Open
Abstract
Modern orthopaedic implants use lattice structures that act as 3D scaffolds to enhance bone growth into and around implants. Stochastic scaffolds are of particular interest as they mimic the architecture of trabecular bone and can combine isotropic properties and adjustable structure. The existing research mainly concentrates on controlling the mechanical and biological performance of periodic lattices by adjusting pore size and shape. Still, less is known on how we can control the performance of stochastic lattices through their design parameters: nodal connectivity, strut density and strut thickness. To elucidate this, four lattice structures were evaluated with varied strut densities and connectivity, hence different local geometry and mechanical properties: low apparent modulus, high apparent modulus, and two with near-identical modulus. Pre-osteoblast murine cells were seeded on scaffolds and cultured in vitro for 28 days. Cell adhesion, proliferation and differentiation were evaluated. Additionally, the expression levels of key osteogenic biomarkers were used to assess the effect of each design parameter on the quality of newly formed tissue. The main finding was that increasing connectivity increased the rate of osteoblast maturation, tissue formation and mineralisation. In detail, doubling the connectivity, over fixed strut density, increased collagen type-I by 140%, increased osteopontin by 130% and osteocalcin by 110%. This was attributed to the increased number of acute angles formed by the numerous connected struts, which facilitated the organization of cells and accelerated the cell cycle. Overall, increasing connectivity and adjusting strut density is a novel technique to design stochastic structures which combine a broad range of biomimetic properties and rapid ossification.
Collapse
Affiliation(s)
- Stylianos Kechagias
- Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | | | - Joseph Broomfield
- Centre for Bio Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom
- Department of Surgery and Cancer, Imperial College London, London, United Kingdom
| | - Kenny Malpartida-Cardenas
- Centre for Bio Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom
- Department of Infectious Disease, Imperial College London, London, United Kingdom
| | - Ruth Reid
- Centre for Bio Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom
| | - Pantelis Georgiou
- Centre for Bio Inspired Technology, Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom
| | - Richard J. van Arkel
- Department of Mechanical Engineering, Imperial College London, London, United Kingdom
| | | |
Collapse
|
23
|
Zheng W, Wu D, Zhang Y, Luo Y, Yang L, Xu X, Luo F. Multifunctional modifications of polyetheretherketone implants for bone repair: A comprehensive review. BIOMATERIALS ADVANCES 2023; 154:213607. [PMID: 37651963 DOI: 10.1016/j.bioadv.2023.213607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 08/16/2023] [Accepted: 08/25/2023] [Indexed: 09/02/2023]
Abstract
Polyetheretherketone (PEEK) has emerged as a highly promising orthopedic implantation material due to its elastic modulus which is comparable to that of natural bone. This polymer exhibits impressive properties for bone implantation such as corrosion resistance, fatigue resistance, self-lubrication and chemical stability. Significantly, compared to metal-based implants, PEEK implants have mechanical properties that are closer to natural bone, which can mitigate the "stress shielding" effect in bone implantation. Nevertheless, PEEK is incapable of inducing osteogenesis due to its bio-inert molecular structure, thereby hindering the osseointegration process. To optimize the clinical application of PEEK, researchers have been working on promoting its bioactivity and endowing this polymer with beneficial properties, such as antibacterial, anti-inflammatory, anti-tumor, and angiogenesis-promoting capabilities. Considering the significant growth of research on PEEK implants over the past 5 years, this review aims to present a timely update on PEEK's modification methods. By highlighting the latest advancements in PEEK modification, we hope to provide guidance and inspiration for researchers in developing the next generation bone implants and optimizing their clinical applications.
Collapse
Affiliation(s)
- Wenzhuo Zheng
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Dongxu Wu
- West China School of Pharmacy, Sichuan University, Chengdu 610041, China
| | - Yaowen Zhang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Yankun Luo
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Lei Yang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Xiangrui Xu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China
| | - Feng Luo
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China School of Stomatology, Sichuan University, Chengdu 610041, China; Department of Prosthodontics, West China School of Stomatology, Sichuan University, Chengdu 610041, China.
| |
Collapse
|
24
|
Rojas-Rojas L, Tozzi G, Guillén-Girón T. A Comprehensive Mechanical Characterization of Subject-Specific 3D Printed Scaffolds Mimicking Trabecular Bone Architecture Biomechanics. Life (Basel) 2023; 13:2141. [PMID: 38004281 PMCID: PMC10672154 DOI: 10.3390/life13112141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 10/25/2023] [Accepted: 10/28/2023] [Indexed: 11/26/2023] Open
Abstract
This study presents a polymeric scaffold designed and manufactured to mimic the structure and mechanical compressive characteristics of trabecular bone. The morphological parameters and mechanical behavior of the scaffold were studied and compared with trabecular bone from bovine iliac crest. Its mechanical properties, such as modulus of elasticity and yield strength, were studied under a three-step monotonic compressive test. Results showed that the elastic modulus of the scaffold was 329 MPa, and the one for trabecular bone reached 336 MPa. A stepwise dynamic compressive test was used to assess the behavior of samples under various loading regimes. With microcomputed tomography (µCT), a three-dimensional reconstruction of the samples was obtained, and their porosity was estimated as 80% for the polymeric scaffold and 88% for trabecular bone. The full-field strain distribution of the samples was measured using in situ µCT mechanics and digital volume correlation (DVC). This provided information on the local microdeformation mechanism of the scaffolds when compared to that of the tissue. The comprehensive results illustrate the potential of the fabricated scaffolds as biomechanical templates for in vitro studies. Furthermore, there is potential for extending this structure and fabrication methodology to incorporate suitable biocompatible materials for both in vitro and in vivo clinical applications.
Collapse
Affiliation(s)
- Laura Rojas-Rojas
- Materials Science and Engineering School, Tecnológico de Costa Rica, Cartago 30109, Costa Rica;
| | - Gianluca Tozzi
- School of Engineering, University of Greenwich, Chatham ME4 4TB, UK;
- School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth PO1 3DJ, UK
| | - Teodolito Guillén-Girón
- Materials Science and Engineering School, Tecnológico de Costa Rica, Cartago 30109, Costa Rica;
| |
Collapse
|
25
|
Skwira A, Szewczyk A, Barros J, Laranjeira M, Monteiro FJ, Sądej R, Prokopowicz M. Biocompatible antibiotic-loaded mesoporous silica/bioglass/collagen-based scaffolds as bone drug delivery systems. Int J Pharm 2023; 645:123408. [PMID: 37703959 DOI: 10.1016/j.ijpharm.2023.123408] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 08/28/2023] [Accepted: 09/10/2023] [Indexed: 09/15/2023]
Abstract
Local delivery of antibiotics has gained increasing interest in the treatment of osteomyelitis due to its effectiveness and safety. Since the regeneration of bone tissue at the site of infection is as important as bacterial eradication, implantable drug delivery systems should not only release the drugs in a proper manner but also exert the osseointegration capability. Herein, we present an implantable drug delivery system in a scaffold form with a unique set of features for local treatment of osteomyelitis. For the first time, collagen type I, ciprofloxacin-loaded mesoporous silica, and bioglass were combined to obtain scaffolds using the molding method. Drug-loaded mesoporous silica was blended with polydimethylsiloxane to prolong the drug release, whereas bioglass served as a remineralization agent. Collagen-silica scaffolds were evaluated in terms of physicochemical properties, drug release rate, mineralization potential, osteoblast response in vitro, antimicrobial activity, and biological properties using an in vivo preclinical model - chick embryo chorioallantoic membrane (CAM). The desirable multifunctionality of the proposed collagen-silica scaffolds was confirmed. They released the ciprofloxacin for 80 days, prevented biofilm development, and induced hydroxyapatite formation. Moreover, the resulting macroporous structure of the scaffolds promoted osteoblast attachment, infiltration, and proliferation. Collagen-silica scaffolds were also biocompatible and effectively integrated with CAM.
Collapse
Affiliation(s)
- Adrianna Skwira
- Department of Physical Chemistry, Faculty of Pharmacy, Medical University of Gdańsk, Hallera 107, 80-416 Gdańsk, Poland; Department of Molecular Enzymology and Oncology, Intercollegiate Faculty of Biotechnology, University of Gdańsk and Medical University of Gdańsk, Dębinki 1, 80-211 Gdańsk, Poland.
| | - Adrian Szewczyk
- Department of Physical Chemistry, Faculty of Pharmacy, Medical University of Gdańsk, Hallera 107, 80-416 Gdańsk, Poland.
| | - Joana Barros
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen 208, 4200-135 Porto, Portugal; INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen 208, 4200-135 Porto, Portugal; FEUP-Faculdade de Engenharia, Departamento de Engenharia Metalúrgica e de Materiais, Universidade do Porto, Rua Dr. Roberto Frias, s/n 4200-465, Porto, Portugal.
| | - Marta Laranjeira
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen 208, 4200-135 Porto, Portugal; INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen 208, 4200-135 Porto, Portugal; Porto Comprehensive Cancer Center Raquel Seruca (P.CCC), R. Dr. António Bernardino de Almeida, 4200-072 Porto, Portugal.
| | - Fernando Jorge Monteiro
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen 208, 4200-135 Porto, Portugal; INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen 208, 4200-135 Porto, Portugal; Porto Comprehensive Cancer Center Raquel Seruca (P.CCC), R. Dr. António Bernardino de Almeida, 4200-072 Porto, Portugal; FEUP-Faculdade de Engenharia, Departamento de Engenharia Metalúrgica e de Materiais, Universidade do Porto, Rua Dr. Roberto Frias, s/n 4200-465, Porto, Portugal.
| | - Rafał Sądej
- Department of Molecular Enzymology and Oncology, Intercollegiate Faculty of Biotechnology, University of Gdańsk and Medical University of Gdańsk, Dębinki 1, 80-211 Gdańsk, Poland.
| | - Magdalena Prokopowicz
- Department of Physical Chemistry, Faculty of Pharmacy, Medical University of Gdańsk, Hallera 107, 80-416 Gdańsk, Poland.
| |
Collapse
|
26
|
Qiu D, Cao C, Prasopthum A, Sun Z, Zhang S, Yang H, Xu Z, Tao J, Ai F, Yang J. Elucidating osseointegration in vivo in 3D printed scaffolds eliciting different foreign body responses. Mater Today Bio 2023; 22:100771. [PMID: 37674779 PMCID: PMC10477687 DOI: 10.1016/j.mtbio.2023.100771] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 08/10/2023] [Accepted: 08/12/2023] [Indexed: 09/08/2023] Open
Abstract
Osseointegration between biomaterial and bone is critical for the clinical success of many orthopaedic and dental implants. However, the mechanisms of in vivo interfacial bonding formation and the role of immune cells in this process remain unclear. In this study, we investigated the bone-scaffold material interfaces in two different 3D printed porous scaffolds (polymer/hydroxyapatite and sintered hydroxyapatite) that elicited different levels of foreign body response (FBR). The polymer/hydroxyapatite composite scaffolds elicited more intensive FBR, which was evidenced by more FBR components, such as macrophages/foreign body giant cells and fibrous tissue, surrounding the material surface. Sintered hydroxyapatite scaffolds showed less intensive FBR compared to the composite scaffolds. The interfacial bonding appeared to form via new bone first forming within the pores of the scaffolds followed by growing towards strut surfaces. In contrast, it was previously thought that bone regeneration starts at biomaterial surfaces via osteogenic stem/progenitor cells first attaching to them. The material-bone interface of the less immunogenic hydroxyapatite scaffolds was heterogenous across all samples, evidenced by the coexistence of osseointegration and FBR components. The presence of FBR components appeared to inhibit osseointegration. Where FBR components were present there was no osseointegration. Our results offer new insight on the in vivo formation of bone-material interface, which highlights the importance of minimizing FBR to facilitate osseointegration for the development of better orthopaedic and dental biomaterials.
Collapse
Affiliation(s)
- Dewei Qiu
- Department of Orthopedic Surgery, The Second Affiliated Hospital of Nanchang University, Jiangxi, China
| | - Chuanliang Cao
- School of Advanced Manufacturing, Nanchang University, Jiangxi, China
| | | | - Zhenchang Sun
- Department of Oncology, The First Affiliated Hospital of Zhengzhou University, Henan, China
| | - Shan Zhang
- School of Advanced Manufacturing, Nanchang University, Jiangxi, China
| | - Hanwen Yang
- School of Advanced Manufacturing, Nanchang University, Jiangxi, China
| | - Zhiyong Xu
- School of Advanced Manufacturing, Nanchang University, Jiangxi, China
| | - Jun Tao
- Department of Orthopedic Surgery, The Second Affiliated Hospital of Nanchang University, Jiangxi, China
| | - Fanrong Ai
- School of Advanced Manufacturing, Nanchang University, Jiangxi, China
| | - Jing Yang
- School of Pharmacy, University of Nottingham, UK
- Biodiscovery Institute, University of Nottingham, UK
| |
Collapse
|
27
|
Li J, Wu X, Liang Z, Wei Z, Chen Z, Wang Y, Li W, Zhang W, Yang R, Qiu H, Li X, Li Q, Chen J. A programmed surface on dental implants sequentially initiates bacteriostasis and osseointegration. Colloids Surf B Biointerfaces 2023; 230:113477. [PMID: 37544027 DOI: 10.1016/j.colsurfb.2023.113477] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 06/18/2023] [Accepted: 07/24/2023] [Indexed: 08/08/2023]
Abstract
Osteogenesis surrounding dental implants is initiated by a series of early physiological events, including the inflammatory response. However, the persistence of an anti-infection surface often results in compromised histocompatibility and osseointegration. Here, we presented a programmed surface containing both silver nanoparticles (AgNPs) and silver ions (Ag+) with a heterogeneous structure and time-dependent functionalities. The AgNPs were located at the surface of the heparin-chitosan polyelectrolyte coating (PEM), whereas Ag+ was distributed at both the surface and inside of the coating under optimized conditions (pH=4). The optimized coating (Ag-4) exhibited potent bactericidal activity at the early stage (12 and 24 h after inoculation) and a sustained antibacterial efficacy in the subsequent stage (one or two weeks), as it gradually depleted. Furthermore, compared to coatings with sustained high silver concentrations in bacteria-cell coculture experiments, the degradable Ag-4 coating demonstrated improved cytocompatibility, better cell viability, and morphology over time. At a later stage (within one month), the in vivo test revealed that Ag-4-coated titanium had superior histocompatibility and osteogenesis outcomes compared to bare titanium in a bacteria-exposed environment. The programmed surface of dental implants presented in this study offers innovative ideas for sequential antibacterial effects and osseointegration.
Collapse
Affiliation(s)
- Jiaojiao Li
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China
| | - Xiaoqin Wu
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China
| | - Zhaojia Liang
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China
| | - Zhangao Wei
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China
| | - Zirui Chen
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China
| | - Yankai Wang
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China
| | - Wei Li
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China
| | - Weibo Zhang
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China
| | - Runhuai Yang
- Department of Biomedical Engineering, Anhui Medical University, Hefei 230032, China
| | - Hua Qiu
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China.
| | - Xiangyang Li
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China.
| | - Quanli Li
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China.
| | - Jialong Chen
- Stomatologic Hospital and College, Anhui Medical University, Key Laboratory of Oral Diseases Research of Anhui Province, Hefei, Anhui 230032, China.
| |
Collapse
|
28
|
Gupta T, Ghosh SB, Bandyopadhyay-Ghosh S, Sain M. Is it possible to 3D bioprint load-bearing bone implants? A critical review. Biofabrication 2023; 15:042003. [PMID: 37669643 DOI: 10.1088/1758-5090/acf6e1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Accepted: 09/05/2023] [Indexed: 09/07/2023]
Abstract
Rehabilitative capabilities of any tissue engineered scaffold rely primarily on the triad of (i) biomechanical properties such as mechanical properties and architecture, (ii) chemical behavior such as regulation of cytokine expression, and (iii) cellular response modulation (including their recruitment and differentiation). The closer the implant can mimic the native tissue, the better it can rehabilitate the damage therein. Among the available fabrication techniques, only 3D bioprinting (3DBP) can satisfactorily replicate the inherent heterogeneity of the host tissue. However, 3DBP scaffolds typically suffer from poor mechanical properties, thereby, driving the increased research interest in development of load-bearing 3DBP orthopedic scaffolds in recent years. Typically, these scaffolds involve multi-material 3D printing, comprising of at-least one bioink and a load-bearing ink; such that mechanical and biological requirements of the biomaterials are decoupled. Ensuring high cellular survivability and good mechanical properties are of key concerns in all these studies. 3DBP of such scaffolds is in early developmental stages, and research data from only a handful of preliminary animal studies are available, owing to limitations in print-capabilities and restrictive materials library. This article presents a topically focused review of the state-of-the-art, while highlighting aspects like available 3DBP techniques; biomaterials' printability; mechanical and degradation behavior; and their overall bone-tissue rehabilitative efficacy. This collection amalgamates and critically analyses the research aimed at 3DBP of load-bearing scaffolds for fulfilling demands of personalized-medicine. We highlight the recent-advances in 3DBP techniques employing thermoplastics and phosphate-cements for load-bearing applications. Finally, we provide an outlook for possible future perspectives of 3DBP for load-bearing orthopedic applications. Overall, the article creates ample foundation for future research, as it gathers the latest and ongoing research that scientists could utilize.
Collapse
Affiliation(s)
- Tanmay Gupta
- Engineered Biomedical Materials Research and Innovation Centre (EnBioMatRIC), Department of Mechanical Engineering, Manipal University Jaipur, Jaipur, Rajasthan, India
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON, Canada
| | - Subrata Bandhu Ghosh
- Engineered Biomedical Materials Research and Innovation Centre (EnBioMatRIC), Department of Mechanical Engineering, Manipal University Jaipur, Jaipur, Rajasthan, India
| | - Sanchita Bandyopadhyay-Ghosh
- Engineered Biomedical Materials Research and Innovation Centre (EnBioMatRIC), Department of Mechanical Engineering, Manipal University Jaipur, Jaipur, Rajasthan, India
| | - Mohini Sain
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
29
|
Hu X, Zhong J, Ao H, Wu X, Chen Y, Peng Z. Iodine-Doped 3D Print Ti Alloy for Antibacterial Therapy on Orthopedic Implants. ACS OMEGA 2023; 8:32990-32997. [PMID: 37720783 PMCID: PMC10500661 DOI: 10.1021/acsomega.3c04721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Accepted: 08/23/2023] [Indexed: 09/19/2023]
Abstract
This study presents a novel approach to mitigating bacterial infections and antibiotic resistance in medical implants through the integration of iodine-doping and 3D printing techniques. Iodine, with its potent antibacterial properties, and titanium alloy (Ti), a popular metal for implants due to its mechanical and biological properties, were combined via electrodeposition on 3D-printed titanium alloy (3D-Ti) implants. Scanning electron microscopy, energy dispersive spectroscopy, and X-ray photoelectron spectroscopy confirmed the successful creation of iodine-doped titanium implants with improved iodine content due to the rough surface of the 3D-printed material. In vitro studies revealed that these implants significantly inhibited bacterial adhesion and biofilm formation and showed favorable release kinetics for iodine ions. Biocompatibility tests demonstrated no cytotoxic effects and good hemocompatibility. The implants demonstrated enhanced antimicrobial efficacy against Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) bacteria strains. The findings imply that the integration of iodine-doping and 3D printing technologies is a promising strategy for treating postoperative infections associated with medical implants, consequently bettering the prognosis for patients. Future investigations are encouraged to delve into the long-standing impacts and prospective clinical utility of this groundbreaking methodology.
Collapse
Affiliation(s)
- Xiaodong Hu
- The
Affiliated Lihuili Hospital, Ningbo University, Ningbo 315040, China
| | - Jiaqi Zhong
- The
Affiliated Lihuili Hospital, Ningbo University, Ningbo 315040, China
| | - Haiyong Ao
- Jiangxi
Key Laboratory of Nanobiomaterials & School of Materials Science
and Engineering, East China Jiaotong University, Nanchang 330000, China
| | - Xinhui Wu
- Xianju
County People’s Hospital, Taizhou 317300, China
| | - Yujiong Chen
- The
Affiliated Lihuili Hospital, Ningbo University, Ningbo 315040, China
| | - Zhaoxiang Peng
- The
Affiliated Lihuili Hospital, Ningbo University, Ningbo 315040, China
| |
Collapse
|
30
|
Ye K, Zhang X, Shangguan L, Liu X, Nie X, Qiao Y. Manganese-Implanted Titanium Modulates the Crosstalk between Bone Marrow Mesenchymal Stem Cells and Macrophages to Improve Osteogenesis. J Funct Biomater 2023; 14:456. [PMID: 37754870 PMCID: PMC10531852 DOI: 10.3390/jfb14090456] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 08/25/2023] [Accepted: 08/25/2023] [Indexed: 09/28/2023] Open
Abstract
Manganese (Mn) is an essential micronutrient in various physiological processes, but its functions in bone metabolism remain undefined. This is partly due to the interplay between immune and bone cells because Mn plays a central role in the immune system. In this study, we utilized the plasma immersion ion implantation and deposition (PIII&D) technique to introduce Mn onto the titanium surface. The results demonstrated that Mn-implanted surfaces stimulated the shift of macrophages toward the M1 phenotype and had minimal effects on the osteogenic differentiation of mouse bone marrow mesenchymal stem cells (mBMSCs) under mono-culture conditions. However, they promoted the M2 polarization of macrophages and improved the osteogenic activities of mBMSCs under co-culture conditions, indicating the importance of the crosstalk between mBMSCs and macrophages mediated by Mn in osteogenic activities. This study provides a positive incentive for the application of Mn in the field of osteoimmunology.
Collapse
Affiliation(s)
- Kuicai Ye
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China; (K.Y.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xianming Zhang
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China; (K.Y.)
| | - Li Shangguan
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China; (K.Y.)
- School of Materials Science, Shanghai University, Shanghai 200444, China
| | - Xingdan Liu
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China; (K.Y.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xiaoshuang Nie
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China; (K.Y.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yuqin Qiao
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050, China; (K.Y.)
| |
Collapse
|
31
|
Jiang P, Zhang Y, Hu R, Shi B, Zhang L, Huang Q, Yang Y, Tang P, Lin C. Advanced surface engineering of titanium materials for biomedical applications: From static modification to dynamic responsive regulation. Bioact Mater 2023; 27:15-57. [PMID: 37035422 PMCID: PMC10074421 DOI: 10.1016/j.bioactmat.2023.03.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 03/10/2023] [Accepted: 03/10/2023] [Indexed: 03/29/2023] Open
Abstract
Titanium (Ti) and its alloys have been widely used as orthopedic implants, because of their favorable mechanical properties, corrosion resistance and biocompatibility. Despite their significant success in various clinical applications, the probability of failure, degradation and revision is undesirably high, especially for the patients with low bone density, insufficient quantity of bone or osteoporosis, which renders the studies on surface modification of Ti still active to further improve clinical results. It is discerned that surface physicochemical properties directly influence and even control the dynamic interaction that subsequently determines the success or rejection of orthopedic implants. Therefore, it is crucial to endow bulk materials with specific surface properties of high bioactivity that can be performed by surface modification to realize the osseointegration. This article first reviews surface characteristics of Ti materials and various conventional surface modification techniques involving mechanical, physical and chemical treatments based on the formation mechanism of the modified coatings. Such conventional methods are able to improve bioactivity of Ti implants, but the surfaces with static state cannot respond to the dynamic biological cascades from the living cells and tissues. Hence, beyond traditional static design, dynamic responsive avenues are then emerging. The dynamic stimuli sources for surface functionalization can originate from environmental triggers or physiological triggers. In short, this review surveys recent developments in the surface engineering of Ti materials, with a specific emphasis on advances in static to dynamic functionality, which provides perspectives for improving bioactivity and biocompatibility of Ti implants.
Collapse
|
32
|
Imai H, Prati C, Zamparini F, Iezzi G, Botticelli D, Gandolfi MG, Baba S. ESEM-EDX Mineralization and Morphological Analysis of Human Retrieved Maxillary Sinus Bone Graft Biopsies before Loading. J Funct Biomater 2023; 14:391. [PMID: 37504886 PMCID: PMC10382039 DOI: 10.3390/jfb14070391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 07/10/2023] [Accepted: 07/22/2023] [Indexed: 07/29/2023] Open
Abstract
This study aimed to analyze the morphology of bone graft granules, the presence of granule demineralization, and bone morphology in retrieved human maxillary sinus bone graft biopsies. Healthy patients underwent sinus bone augmentation using lateral access. Two different dimensions of the antrostomy were performed, a 4 mm or 8 mm height. After 6 months, all sites received one implant using a flap technique, crestal positioning, and submerged healing. Implant biopsies were retrieved after 3 months and were histologically processed. The ESEM analysis was performed on the entire portion of the peri-implant bone (up to 750 µm from the implant thread). Three different regions of interest (ROIs) were selected: the coronal, middle, and apical portions of the implant. In these areas, EDX was performed, and calcium (Ca), phosphate (P), nitrogen (N), and their atomic ratios (Ca/P, Ca/N, and P/N) were calculated. Different bone tissue electron-dense areas were detected through grayscale intensity quantification of ESEM images with different organic (N) or inorganic (Ca,P) compositions. A total of 16 biopsies from 16 healthy patients were analyzed. Bone graft granules were mostly detected in the apical ROI. New bone tissue bridges were detected in the apical and middle ROI. These structures, with lower Ca/N and P/N ratios, were connected and enveloped the bone graft granules. Cortical ROI revealed the most mineralized bone tissue. Conclusions: After 9 months, bone graft resorption was only partially completed and new bone tissue appeared less mineralized in the middle and apical ROI than in the coronal ROI.
Collapse
Affiliation(s)
- Hideki Imai
- Department of Oral Implantology, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan
| | - Carlo Prati
- School of Dentistry, Department of Biomedical and Neuromotor Sciences, University of Bologna, 40125 Bologna, Italy
| | - Fausto Zamparini
- School of Dentistry, Department of Biomedical and Neuromotor Sciences, University of Bologna, 40125 Bologna, Italy
- Laboratory of Biomaterials and Oral Pathology, School of Dentistry, 40125 Bologna, Italy
| | - Giovanna Iezzi
- Department of Medical Oral and Biotechnological Sciences, University of Chieti, 66100 Chieti, Italy
| | - Daniele Botticelli
- Department of Oral Implantology, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan
- ARDEC Academy, 47923 Rimini, Italy
| | - Maria Giovanna Gandolfi
- School of Dentistry, Department of Biomedical and Neuromotor Sciences, University of Bologna, 40125 Bologna, Italy
- Laboratory of Biomaterials and Oral Pathology, School of Dentistry, 40125 Bologna, Italy
| | - Shunsuke Baba
- Department of Oral Implantology, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Osaka, Japan
| |
Collapse
|
33
|
Xu J, Chen C, Gan S, Liao Y, Fu R, Hou C, Yang S, Zheng Z, Chen W. The Potential Value of Probiotics after Dental Implant Placement. Microorganisms 2023; 11:1845. [PMID: 37513016 PMCID: PMC10383117 DOI: 10.3390/microorganisms11071845] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 07/15/2023] [Accepted: 07/18/2023] [Indexed: 07/30/2023] Open
Abstract
Dental implantation is currently the optimal solution for tooth loss. However, the health and stability of dental implants have emerged as global public health concerns. Dental implant placement, healing of the surgical site, osseointegration, stability of bone tissues, and prevention of peri-implant diseases are challenges faced in achieving the long-term health and stability of implants. These have been ongoing concerns in the field of oral implantation. Probiotics, as beneficial microorganisms, play a significant role in the body by inhibiting pathogens, promoting bone tissue homeostasis, and facilitating tissue regeneration, modulating immune-inflammatory levels. This review explores the potential of probiotics in addressing post-implantation challenges. We summarize the existing research regarding the importance of probiotics in managing dental implant health and advocate for further research into their potential applications.
Collapse
Affiliation(s)
- Jia Xu
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Chenfeng Chen
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Department of General Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Shuaiqi Gan
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Yihan Liao
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Ruijie Fu
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Chuping Hou
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Shuhan Yang
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Zheng Zheng
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Wenchuan Chen
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Jinjiang Out-Patient Section, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| |
Collapse
|
34
|
Cui JT, Wang XY, Mu XD, Huang M, Wang YD, Luo Q, He HX. Bone marrow stromal cell-derived exosome combinate with fibrin on tantalum coating titanium implant accelerates osseointegration. Front Bioeng Biotechnol 2023; 11:1198545. [PMID: 37496851 PMCID: PMC10367419 DOI: 10.3389/fbioe.2023.1198545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Accepted: 06/20/2023] [Indexed: 07/28/2023] Open
Abstract
This study aims to present a sustainably releasing system of exosomes-fibrin combinate loaded on tantalum-coating titanium implants. We hope to investigate potential effects of the system on osseointegration between tantalum coating titanium implants and its surrounding bone tissue. Exosomes derived from rabbit bone marrow stromal cells (rBMSCs) and fibrin were deposited onto the micro-nanostructure tantalum coating surface (Ta + exo + FI) and compared to control groups, including tantalum coating (Ta), tantalum coating loaded exosomes (Ta + exo) and tantalum coating loaded fibrin (Ta + FI). The optimal concentration of loading exosomes, exosomes uptake capacity by BMSCs, and the effect of controlled-release by fibrin were assessed by laser scanning confocal microscope (LCSM) and microplate reader. The optimal concentration of exosomes was 1 μg/μL. Adhesion, proliferation, and osteogenic differentiation ability of BMSCs on different materials were assessed in vitro. Finally, osseointegrative capacity of Ta, Ta + exo, Ta + FI, Ta + exo + FI implants in rabbit tibia were respectively evaluated with histology and bone-implant contact ratio (BIC%). It was demonstrated that exosome sustained-release system with fibrin loading on the tantalum coating was successfully established. Fibrin contribute to exosomes release extension from 2d to 6d. Furthermore, Ta + exo + FI significantly promoted adhesion, proliferation, and osteogenic differentiation of BMSCs. In vivo, the implants in Ta + exo + FI group displayed the highest osseointegrative capability than those in other groups. It is concluded that this exosome delivery system on the implants may be an effective way for tantalum coating titanium implants to promote osseointegration between implant and its surrounding bone tissue.
Collapse
Affiliation(s)
- Jian-Tong Cui
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
- Shannxi Provincial Crops Hospital of Chinese People’s Armed Police Forces, Xian, China
| | - Xin-Yuan Wang
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
- Medical School of Chinese PLA, Beijing, China
| | - Xiao-Dan Mu
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Meng Huang
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Ya-Di Wang
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
- Medical School of Chinese PLA, Beijing, China
| | - Qiang Luo
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Hui-Xia He
- Department of Stomatology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| |
Collapse
|
35
|
Radwan-Pragłowska J, Janus Ł, Galek T, Szajna E, Sierakowska A, Łysiak K, Tupaj M, Bogdał D. Evaluation of Physiochemical and Biological Properties of Biofunctionalized Mg-Based Implants Obtained via Large-Scale PEO Process for Dentistry Applications. J Funct Biomater 2023; 14:338. [PMID: 37504833 PMCID: PMC10381468 DOI: 10.3390/jfb14070338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Revised: 05/23/2023] [Accepted: 06/07/2023] [Indexed: 07/29/2023] Open
Abstract
An increasing number of tooth replacement procedures ending with implant failure generates a great need for the delivery of novel biomedical solutions with appropriate mechanical characteristics that would mimic natural tissue and undergo biodegradation. This phenomenon constitutes a significant difficulty for scientists, since currently applied biomaterials dedicated for this purpose are based on stainless steel, Ti, and Ti and CoCr alloys. One of the most promising raw materials is magnesium, which has been proven to promote bone regeneration and accelerate the tissue healing process. Nevertheless, its high reactivity with body fluid components is associated with fast and difficult-to-control biocorrosion, which strongly limits the application of Mg implants as medical devices. The achievement of appropriate functionality, both physiochemical and biological, to enable the commercial use of Mg biomaterials is possible only after their superficial modification. Therefore, the obtainment of uniform, reproducible coatings increasing resistance to the aqueous environment of the human body combined with a nanostructured surface that enhances implant-cell behaviors is an extremely important issue. Herein, we present a successful strategy for the modification of Mg implants via the PEO process, resulting in the obtainment of biomaterials with lower corrosion rates and superior biological properties, such as the promotion of extracellular matrix formation and a positive impact on the proliferation of MG-63 cells. The implants were investigated regarding their chemical composition using the FT-IR and XRD methods, which revealed that MgO layer formation, as well as the incorporation of electrolyte components such as fluorine and silica, were responsible for the increased microhardness of the samples. An extensive study of the biomaterials' morphology confirmed that successful surface modification led to a microporous structure suitable for the attachment and proliferation of cells. The three-layer nature of the newly-formed coatings, typical for PEO modification, was confirmed via cross-section analysis. A biocorrosion and biodegradation study proved that applied modification increased their resistance to body fluids. The cell culture study performed herein confirmed that the correct adjustment of modification parameters results in a lack of cytotoxicity of the magnesium implants, cell proliferation enhancement, and improvement in extracellular matrix formation.
Collapse
Affiliation(s)
- Julia Radwan-Pragłowska
- Department of Biotechnology and Physical Chemistry, Faculty of Chemical Engineering and Technology, Cracow University of Technology, Warszawska 24 Street, 31-155 Cracow, Poland
| | - Łukasz Janus
- Department of Biotechnology and Physical Chemistry, Faculty of Chemical Engineering and Technology, Cracow University of Technology, Warszawska 24 Street, 31-155 Cracow, Poland
| | - Tomasz Galek
- Faculty of Mechanics and Technology, Rzeszow University of Technology, Kwiatkowskiego 4 Street, 37-450 Stalowa Wola, Poland
| | - Ernest Szajna
- WEA Techlab Sp. z o. o., Perla 10, 41-301 Dabrowa Gornicza, Poland
| | - Aleksandra Sierakowska
- Department of Biotechnology and Physical Chemistry, Faculty of Chemical Engineering and Technology, Cracow University of Technology, Warszawska 24 Street, 31-155 Cracow, Poland
| | - Karol Łysiak
- Faculty of Mechanics and Technology, Rzeszow University of Technology, Kwiatkowskiego 4 Street, 37-450 Stalowa Wola, Poland
| | - Mirosław Tupaj
- Faculty of Mechanics and Technology, Rzeszow University of Technology, Kwiatkowskiego 4 Street, 37-450 Stalowa Wola, Poland
| | - Dariusz Bogdał
- Department of Biotechnology and Physical Chemistry, Faculty of Chemical Engineering and Technology, Cracow University of Technology, Warszawska 24 Street, 31-155 Cracow, Poland
| |
Collapse
|
36
|
Zhu X, Wang C, Bai H, Zhang J, Wang Z, Li Z, Zhao X, Wang J, Liu H. Functionalization of biomimetic mineralized collagen for bone tissue engineering. Mater Today Bio 2023; 20:100660. [PMID: 37214545 PMCID: PMC10199226 DOI: 10.1016/j.mtbio.2023.100660] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/18/2023] [Accepted: 05/04/2023] [Indexed: 05/24/2023] Open
Abstract
Mineralized collagen (MC) is the basic unit of bone structure and function and is the main component of the extracellular matrix (ECM) in bone tissue. In the biomimetic method, MC with different nanostructures of neo-bone have been constructed. Among these, extra-fibrous MC has been approved by regulatory agencies and applied in clinical practice to play an active role in bone defect repair. However, in the complex microenvironment of bone defects, such as in blood supply disorders and infections, MC is unable to effectively perform its pro-osteogenic activities and needs to be functionalized to include osteogenesis and the enhancement of angiogenesis, anti-infection, and immunomodulation. This article aimed to discuss the preparation and biological performance of MC with different nanostructures in detail, and summarize its functionalization strategy. Then we describe the recent advances in the osteo-inductive properties and multifunctional coordination of MC. Finally, the latest research progress of functionalized biomimetic MC, along with the development challenges and future trends, are discussed. This paper provides a theoretical basis and advanced design philosophy for bone tissue engineering in different bone microenvironments.
Collapse
Affiliation(s)
- Xiujie Zhu
- Department of Orthopedics, The Second Hospital of Jilin University, 4110 Yatai Street, Changchun, 130041, PR China
| | - Chenyu Wang
- Department of Plastic and Reconstruct Surgery, The First Hospital of Jilin University, 1 Xinmin Street, Changchun, 130021, PR China
| | - Haotian Bai
- Department of Orthopedics, The Second Hospital of Jilin University, 4110 Yatai Street, Changchun, 130041, PR China
| | - Jiaxin Zhang
- Department of Orthopedics, The Second Hospital of Jilin University, 4110 Yatai Street, Changchun, 130041, PR China
| | - Zhonghan Wang
- Department of Orthopedics, The Second Hospital of Jilin University, 4110 Yatai Street, Changchun, 130041, PR China
| | - Zuhao Li
- Department of Orthopedics, The Second Hospital of Jilin University, 4110 Yatai Street, Changchun, 130041, PR China
| | - Xin Zhao
- Department of Orthopedics, The Second Hospital of Jilin University, 4110 Yatai Street, Changchun, 130041, PR China
| | - Jincheng Wang
- Department of Orthopedics, The Second Hospital of Jilin University, 4110 Yatai Street, Changchun, 130041, PR China
| | - He Liu
- Department of Orthopedics, The Second Hospital of Jilin University, 4110 Yatai Street, Changchun, 130041, PR China
| |
Collapse
|
37
|
Nguyen AK, Nelson SB, Skoog SA, Jaipan P, Petrochenko PE, Kaiser A, Lo L, Moreno J, Narayan RJ, Goering PL, Kumar G. Effect of simulated body fluid formulation on orthopedic device apatite-forming ability assessment. J Biomed Mater Res B Appl Biomater 2023; 111:987-995. [PMID: 36444900 DOI: 10.1002/jbm.b.35207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 10/17/2022] [Accepted: 11/13/2022] [Indexed: 11/30/2022]
Abstract
Integration of native bone into orthopedic devices is a key factor in long-term implant success. The material-tissue interface is generally accepted to consist of a hydroxyapatite layer so bioactive materials that can spontaneously generate this hydroxyapatite layer after implantation may improve patient outcomes. Per the ISO 22317:2014 standard, "Implants for surgery - In vitro evaluation for apatite-forming ability of implant materials," bioactivity performance statements can be assessed by soaking the material in simulated body fluid (SBF) and evaluating the surface for the formation of a hydroxyapatite layer; however, variations in test methods may alter hydroxyapatite formation and result in false-positive assessments. The goal of this study was to identify the effect of SBF formulation on bioactivity assessment. Bioglass® (45S5 and S53P4) and non-bioactive Ti-6Al-4V were exposed to SBF formulations varying in calcium ion and phosphate concentrations as well as supporting ion concentrations. Scanning electron microscopy and X-ray powder diffraction evaluation of the resulting hydroxyapatite layers revealed that SBF enriched with double or quadruple the calcium and phosphate ion concentrations increased hydroxyapatite crystal size and quantity compared to the standard formulation and can induce hydroxyapatite crystallization on surfaces traditionally considered non-bioactive. Altering concentrations of other ions, for example, bicarbonate, changed hydroxyapatite induction time, quantity, and morphology. For studies evaluating the apatite-forming ability of a material to support bioactivity performance statements, test method parameters must be adequately described and controlled. It is unclear if apatite formation after exposure to any of the SBF formulations is representative of an in vivo biological response. The ISO 23317 standard test method should be further developed to provide additional guidance on apatite characterization and interpretation of the results.
Collapse
Affiliation(s)
- Alexander K Nguyen
- Joint Department of Biomedical Engineering, UNC/NCSU, Raleigh, North Carolina, USA.,Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Sarah B Nelson
- Office of Product Evaluation and Quality, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Shelby A Skoog
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Panupong Jaipan
- Joint Department of Biomedical Engineering, UNC/NCSU, Raleigh, North Carolina, USA
| | - Peter E Petrochenko
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Aric Kaiser
- Office of Product Evaluation and Quality, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Linh Lo
- Office of Product Evaluation and Quality, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Jose Moreno
- Office of Product Evaluation and Quality, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Roger J Narayan
- Joint Department of Biomedical Engineering, UNC/NCSU, Raleigh, North Carolina, USA
| | - Peter L Goering
- Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Girish Kumar
- Office of Product Evaluation and Quality, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| |
Collapse
|
38
|
Chen S, Li H, Bai Y, Zhang J, Ikoma T, Huang D, Li X, Chen W. Hierarchical and urchin-like chitosan/hydroxyapatite microspheres as drug-laden cell carriers. Int J Biol Macromol 2023; 238:124039. [PMID: 36921830 DOI: 10.1016/j.ijbiomac.2023.124039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 03/07/2023] [Accepted: 03/10/2023] [Indexed: 03/18/2023]
Abstract
Biopolymer/hydroxyapatite (HAp) composites are one type of the most promising materials for a variety of biomedical applications. In this study, hierarchical and urchin-like chitosan/HAp nanowire (HU-CS/HAp NW) microspheres were for the first time synthesized by in situ hydrothermal treatment of chitosan/HAp (CS/HAp) microspheres in the acetic acid solution. The results indicate that HU-CS/HAp NW microspheres were spherical in morphology with a diameter of 100-300 μm. Their surface was mainly constructed by numerous HAp NWs with the diameter of 80-120 nm and showed a hierarchical and urchin-like nanofibrous architecture. It was found that the acidic hydrothermal treatment caused an in situ conversion of HAp NPs to HAp NWs. In vitro biocompatible evaluation indicates that HU-CS/HAp NW microspheres showed an enhanced cell attachment and proliferation due to the presence of hierarchical and urchin-like architecture. Furthermore, HU-CS/HAp NW microspheres showed a good adsorption capacity for tetracycline hydrochloride (model drug, one of the most representative antibiotics) with a higher adsorption capacity than CS/HAp microspheres and well maintained their antibacterial efficacy to inhibit the growth of bacteria: Escherichia coli and Staphylococcus aureus. Thus, the present HU-CS/HAp NW microspheres would be applicable as novel drug-laden cell carriers.
Collapse
Affiliation(s)
- Song Chen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China.
| | - Hao Li
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Yajia Bai
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Jianan Zhang
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Toshiyuki Ikoma
- Department of Materials Science and Engineering, School of Materials and Chemical Technology, Tokyo Institute of Technology, Tokyo 152-8550, Japan
| | - Di Huang
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China.
| | - Xiaona Li
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China
| | - Weiyi Chen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, 030024, China.
| |
Collapse
|
39
|
Gao M, He D, Cui L, Ma L, Tan Z, Zhou Z, Guo X. Investigation on the Microstructure and Mechanical Properties of the Ti-Ta Alloy with Unmelted Ta Particles by Laser Powder Bed Fusion. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2208. [PMID: 36984086 PMCID: PMC10051491 DOI: 10.3390/ma16062208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/06/2023] [Accepted: 03/07/2023] [Indexed: 06/18/2023]
Abstract
Titanium-tantalum (Ti-Ta) alloy has excellent biomechanical properties with high strength and low Young's modulus, showing great application potential in the biomedical industry. In this study, Ti-Ta alloy samples were prepared by laser powder bed fusion (LPBF) technology with mixed pure 75 wt.% Ti and 25 wt.% Ta powders as the feedstock. The maximum relative density of Ti-Ta samples prepared by LPBF reached 99.9%. It is well-accepted that four nonequilibrium phases, namely, α', α″ and metastable β phase exist in Ti-Ta alloys. The structure of α', α″ and β are hexagonal close-packed (HCP), base-centered orthorhombic (BCO) and body-centered cubic (BCC), respectively. X-ray Diffraction (XRD) analysis showed that the α' phase transformed to the α″ phase with the increase of energy density. The lamellar α'/α″ phases and the α″ twins were generated in the prior β phase. The microstructure and mechanical properties of the Ti-Ta alloy were optimized with different LPBF processing parameters. The samples prepared by LPBF energy density of 381 J/mm3 had a favorable ultimate strength (UTS) of 1076 ± 2 MPa and yield strength of 795 ± 16 MPa. The samples prepared by LPBF energy density of 76 had excellent ductility, with an elongation of 31% at fracture.
Collapse
Affiliation(s)
- Mu Gao
- Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing 100124, China
| | - Dingyong He
- Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing 100124, China
- Beijing Engineering Research Center of Eco-Materials and LCA, Beijing 100124, China
| | - Li Cui
- Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing 100124, China
| | - Lixia Ma
- Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing 100124, China
| | - Zhen Tan
- Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing 100124, China
| | - Zheng Zhou
- Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing 100124, China
| | - Xingye Guo
- Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing 100124, China
| |
Collapse
|
40
|
Jiao J, Hong Q, Zhang D, Wang M, Tang H, Yang J, Qu X, Yue B. Influence of porosity on osteogenesis, bone growth and osteointegration in trabecular tantalum scaffolds fabricated by additive manufacturing. Front Bioeng Biotechnol 2023; 11:1117954. [PMID: 36777251 PMCID: PMC9911888 DOI: 10.3389/fbioe.2023.1117954] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 01/18/2023] [Indexed: 01/28/2023] Open
Abstract
Porous tantalum implants are a class of materials commonly used in clinical practice to repair bone defects. However, the cumbersome and problematic preparation procedure have limited their widespread application. Additive manufacturing has revolutionized the design and process of orthopedic implants, but the pore architecture feature of porous tantalum scaffolds prepared from additive materials for optimal osseointegration are unclear, particularly the influence of porosity. We prepared trabecular bone-mimicking tantalum scaffolds with three different porosities (60%, 70% and 80%) using the laser powder bed fusing technique to examine and compare the effects of adhesion, proliferation and osteogenic differentiation capacity of rat mesenchymal stem cells on the scaffolds in vitro. The in vivo bone ingrowth and osseointegration effects of each scaffold were analyzed in a rat femoral bone defect model. Three porous tantalum scaffolds were successfully prepared and characterized. In vitro studies showed that scaffolds with 70% and 80% porosity had a better ability to osteogenic proliferation and differentiation than scaffolds with 60% porosity. In vivo studies further confirmed that tantalum scaffolds with the 70% and 80% porosity had a better ability for bone ingrowh than the scaffold with 60% porosity. As for osseointegration, more bone was bound to the material in the scaffold with 70% porosity, suggesting that the 3D printed trabecular tantalum scaffold with 70% porosity could be the optimal choice for subsequent implant design, which we will further confirm in a large animal preclinical model for better clinical use.
Collapse
Affiliation(s)
- Juyang Jiao
- Department of Bone and Joint Surgery, Department of Orthopedics, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Qimin Hong
- Department of Bone and Joint Surgery, Department of Orthopedics, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Dachen Zhang
- Shenzhen Dazhou Medical Technology Co., Ltd., Shenzhen, Guangdong, China,Center of Biomedical Materials 3D Printing, National Engineering Laboratory for Polymer Complex Structure Additive Manufacturing, Baoding, Hebei, China
| | - Minqi Wang
- Department of Bone and Joint Surgery, Department of Orthopedics, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Haozheng Tang
- Department of Bone and Joint Surgery, Department of Orthopedics, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Jingzhou Yang
- Shenzhen Dazhou Medical Technology Co., Ltd., Shenzhen, Guangdong, China,Center of Biomedical Materials 3D Printing, National Engineering Laboratory for Polymer Complex Structure Additive Manufacturing, Baoding, Hebei, China,School of Mechanical and Automobile Engineering, Qingdao University of Technology, Qingdao, Shandong, China,*Correspondence: Jingzhou Yang, ; Xinhua Qu, ; Bing Yue,
| | - Xinhua Qu
- Department of Bone and Joint Surgery, Department of Orthopedics, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China,*Correspondence: Jingzhou Yang, ; Xinhua Qu, ; Bing Yue,
| | - Bing Yue
- Department of Bone and Joint Surgery, Department of Orthopedics, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China,*Correspondence: Jingzhou Yang, ; Xinhua Qu, ; Bing Yue,
| |
Collapse
|
41
|
Enhanced Corrosion Resistance and Local Therapy from Nano-Engineered Titanium Dental Implants. Pharmaceutics 2023; 15:pharmaceutics15020315. [PMID: 36839638 PMCID: PMC9963924 DOI: 10.3390/pharmaceutics15020315] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 01/12/2023] [Accepted: 01/12/2023] [Indexed: 01/19/2023] Open
Abstract
Titanium is the ideal material for fabricating dental implants with favorable biocompatibility and biomechanics. However, the chemical corrosions arising from interaction with the surrounding tissues and fluids in oral cavity can challenge the integrity of Ti implants and leach Ti ions/nanoparticles, thereby causing cytotoxicity. Various nanoscale surface modifications have been performed to augment the chemical and electrochemical stability of Ti-based dental implants, and this review discusses and details these advances. For instance, depositing nanowires/nanoparticles via alkali-heat treatment and plasma spraying results in the fabrication of a nanostructured layer to reduce chemical corrosion. Further, refining the grain size to nanoscale could enhance Ti implants' mechanical and chemical stability by alleviating the internal strain and establishing a uniform TiO2 layer. More recently, electrochemical anodization (EA) has emerged as a promising method to fabricate controlled TiO2 nanostructures on Ti dental implants. These anodized implants enhance Ti implants' corrosion resistance and bioactivity. A particular focus of this review is to highlight critical advances in anodized Ti implants with nanotubes/nanopores for local drug delivery of potent therapeutics to augment osseo- and soft-tissue integration. This review aims to improve the understanding of novel nano-engineered Ti dental implant modifications, focusing on anodized nanostructures to fabricate the next generation of therapeutic and corrosion-resistant dental implants. The review explores the latest developments, clinical translation challenges, and future directions to assist in developing the next generation of dental implants that will survive long-term in the complex corrosive oral microenvironment.
Collapse
|
42
|
Palmquist A, Jolic M, Hryha E, Shah FA. Complex geometry and integrated macro-porosity: Clinical applications of electron beam melting to fabricate bespoke bone-anchored implants. Acta Biomater 2023; 156:125-145. [PMID: 35675890 DOI: 10.1016/j.actbio.2022.06.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 05/16/2022] [Accepted: 06/01/2022] [Indexed: 01/18/2023]
Abstract
The last decade has witnessed rapid advancements in manufacturing technologies for biomedical implants. Additive manufacturing (or 3D printing) has broken down major barriers in the way of producing complex 3D geometries. Electron beam melting (EBM) is one such 3D printing process applicable to metals and alloys. EBM offers build rates up to two orders of magnitude greater than comparable laser-based technologies and a high vacuum environment to prevent accumulation of trace elements. These features make EBM particularly advantageous for materials susceptible to spontaneous oxidation and nitrogen pick-up when exposed to air (e.g., titanium and titanium-based alloys). For skeletal reconstruction(s), anatomical mimickry and integrated macro-porous architecture to facilitate bone ingrowth are undoubtedly the key features of EBM manufactured implants. Using finite element modelling of physiological loading conditions, the design of a prosthesis may be further personalised. This review looks at the many unique clinical applications of EBM in skeletal repair and the ground-breaking innovations in prosthetic rehabilitation. From a simple acetabular cup to the fifth toe, from the hand-wrist complex to the shoulder, and from vertebral replacement to cranio-maxillofacial reconstruction, EBM has experienced it all. While sternocostal reconstructions might be rare, the repair of long bones using EBM manufactured implants is becoming exceedingly frequent. Despite the various merits, several challenges remain yet untackled. Nevertheless, with the capability to produce osseointegrating implants of any conceivable shape/size, and permissive of bone ingrowth and functional loading, EBM can pave the way for numerous fascinating and novel applications in skeletal repair, regeneration, and rehabilitation. STATEMENT OF SIGNIFICANCE: Electron beam melting (EBM) offers unparalleled possibilities in producing contaminant-free, complex and intricate geometries from alloys of biomedical interest, including Ti6Al4V and CoCr. We review the diverse range of clinical applications of EBM in skeletal repair, both as mass produced off-the-shelf implants and personalised, patient-specific prostheses. From replacing large volumes of disease-affected bone to complex, multi-material reconstructions, almost every part of the human skeleton has been replaced with an EBM manufactured analog to achieve macroscopic anatomical-mimickry. However, various questions regarding long-term performance of patient-specific implants remain unaddressed. Directions for further development include designing personalised implants and prostheses based on simulated loading conditions and accounting for trabecular bone microstructure with respect to physiological factors such as patient's age and disease status.
Collapse
Affiliation(s)
- Anders Palmquist
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| | - Martina Jolic
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Eduard Hryha
- Department of Materials and Manufacturing Technologies, Chalmers University of Technology, Gothenburg, Sweden
| | - Furqan A Shah
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| |
Collapse
|
43
|
Sato M, Shah FA. Contributions of Resin Cast Etching to Visualising the Osteocyte Lacuno-Canalicular Network Architecture in Bone Biology and Tissue Engineering. Calcif Tissue Int 2023; 112:525-542. [PMID: 36611094 PMCID: PMC10106349 DOI: 10.1007/s00223-022-01058-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 12/21/2022] [Indexed: 01/09/2023]
Abstract
Recent years have witnessed an evolution of imaging technologies towards sophisticated approaches for visualising cells within their natural environment(s) and for investigating their interactions with other cells, with adjacent anatomical structures, and with implanted biomaterials. Resin cast etching (RCE) is an uncomplicated technique involving sequential acid etching and alkali digestion of resin embedded bone to observe the osteocyte lacuno-canalicular network using scanning electron microscopy. This review summarises the applicability of RCE to bone and the bone-implant interface. Quantitative parameters such as osteocyte size, osteocyte density, and number of canaliculi per osteocyte, and qualitative metrics including osteocyte shape, disturbances in the arrangement of osteocytes and canaliculi, and physical communication between osteocytes and implant surfaces can be investigated. Ageing, osteoporosis, long-term immobilisation, spinal cord injury, osteoarthritis, irradiation, and chronic kidney disease have been shown to impact osteocyte lacuno-canalicular network morphology. In addition to titanium, calcium phosphates, and bioactive glass, observation of direct connectivity between osteocytes and cobalt chromium provides new insights into the osseointegration potential of materials conventionally viewed as non-osseointegrating. Other applications include in vivo and in vitro testing of polymer-based tissue engineering scaffolds and tissue-engineered ossicles, validation of ectopic osteochondral defect models, ex vivo organ culture of whole bones, and observing the effects of gene dysfunction/deletion on the osteocyte lacuno-canalicular network. Without additional contrast staining, any resin embedded specimen (including clinical biopsies) can be used for RCE. The multitude of applications described here attest to the versatility of RCE for routine use within correlative analytical workflows, particularly in biomaterials science.
Collapse
Affiliation(s)
- Mari Sato
- Oral Biochemistry and Molecular Biology, Graduate School of Dental Medicine, Hokkaido University, Sapporo, Japan
| | - Furqan A Shah
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| |
Collapse
|
44
|
Makarov VB, Dedukh NV, Nikolchenko OA. FEATURES OF BONE REMODELING AROUND SURFACE-MODIFIED TITANIUM AND TANTALUM IMPLANTS. WIADOMOSCI LEKARSKIE (WARSAW, POLAND : 1960) 2023; 76:1790-1796. [PMID: 37740972 DOI: 10.36740/wlek202308113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/25/2023]
Abstract
OBJECTIVE The aim: To study the osseointegrative properties of titanium and tantalum implants with different surface structures in animal experiments. PATIENTS AND METHODS Materials and methods: The histological and morphometric study was carried out on 60 male white rats after titanium implants with different surface structures made by 3D printed technology were inserted in the distal femur bone: presented by the multilayered layers of interlacing pores of 300 microns (series 1); rough (> 2 microns) (series 2); and tantalum implants with 300 microns pores and 80% porosity (series 3) as control material. RESULTS Results: On the 30 days we found statistically significant differences in the bone-implant contact rate between the 2nd experiment series (44.77 ± 1.86)% and 1st (59.91 ± 2.86)% (p=0.000047) and 3rd (53.89 ± 2.11)% (р=0.000065), on the 90 days between the 2nd experiment series (51.26 ± 2.7)% and 1st (66.84 ± 2.63)% (p=0.000187) and 3rd (70.35 ± 4.32)% (p=0.000349). There was a difference between the indices of the bone-implant volume at day 90 between the 1st (48.43 ± 2.2)% and 2nd (36.88 ± 2.56)% series (p=0.000919), between the 2nd and 3rd series (51.2 ± 3.06)% (p=0.000107). There were no significant differences between the studied indices in the 1st and 3rd series of the experiment. CONCLUSION Conclusions: Titanium implants with multilayered interlaced pore layers of 300 microns and tantalum with 300 microns pore size and 80% porosity may be promising. Rough-surface titanium also has osseointegrative qualities, but they are lower compared to other materials.
Collapse
Affiliation(s)
| | - Ninel V Dedukh
- D.F. CHEBOTAREV INSTITUTE OF GERONTOLOGY OF THE NATIONAL ACADEMY OF MEDICAL SCIENCES OF UKRAINE, KYIV, UKRAINE
| | - Olga A Nikolchenko
- SYTENKO INSTITUTE OF SPINE AND JOINT PATHOLOGY OF THE NATIONAL ACADEMY OF MEDICAL SCIENCES OF UKRAINE, KHARKIV, UKRAINE
| |
Collapse
|
45
|
Wang Z, Zhang J, Hu J, Yang G. Gene-activated titanium implants for gene delivery to enhance osseointegration. BIOMATERIALS ADVANCES 2022; 143:213176. [PMID: 36327825 DOI: 10.1016/j.bioadv.2022.213176] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 10/22/2022] [Accepted: 10/26/2022] [Indexed: 06/16/2023]
Abstract
Osseointegration is the direct and intimate contact between mineralized tissue and titanium implant at the bone-implant interface. Early establishment and stable maintenance of osseointegration is the key to long-term implant success. However, in patients with compromised conditions such as osteoporosis and patients beginning early load-bearing activities such as walking, lower osseointegration around titanium implants is often observed, which might result in implant early failure. Gene-activated implants show an exciting prospect of combining gene delivery and biomedical implants to solve the problems of poor osseointegration formation, overcoming the shortcomings of protein therapy, including rapid degradation and overdose adverse effects. The conception of gene-activated titanium implants is based on "gene-activated matrix" (GAM), which means scaffolds using non-viral vectors for in situ gene delivery to achieve a long-term and efficient transfection of target cells. Current preclinical studies in animal models have shown that plasmid DNA (pDNA), microRNA (miRNA), and small interference RNA (siRNA) functionalized titanium implants can enhance osseointegration with safety and efficiency, leading to the expectation of applying this technique in dental and orthopedic clinical scenarios. This review aims to comprehensively summarize fabrication strategies, current applications, and futural outlooks of gene-activated implants, emphasizing nucleic acid targets, non-viral vectors, implant surface modification techniques, nucleic acid/vector complexes loading strategies.
Collapse
Affiliation(s)
- Zhikang Wang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310000, China
| | - Jing Zhang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310000, China
| | - Jinxing Hu
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310000, China
| | - Guoli Yang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou 310000, China.
| |
Collapse
|
46
|
Hu J, Ding Y, Tao B, Yuan Z, Yang Y, Xu K, Li X, liu P, Cai K. Surface modification of titanium substrate via combining photothermal therapy and quorum-sensing-inhibition strategy for improving osseointegration and treating biofilm-associated bacterial infection. Bioact Mater 2022; 18:228-241. [PMID: 35387171 PMCID: PMC8961458 DOI: 10.1016/j.bioactmat.2022.03.011] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 01/19/2022] [Accepted: 03/07/2022] [Indexed: 12/11/2022] Open
Abstract
Insufficient osseointegration and biofilm-associated bacterial infection are important challenges for clinical application of titanium (Ti)-based implants. Here, we constructed mesoporous polydopamine (MPDA) nanoparticles (NPs) loaded with luteolin (LUT, a quorum sensing inhibitor), which were further coated with the shell of calcium phosphate (CaP) to construct MPDA-LUT@CaP nanosystem. Then, MPDA-LUT@CaP NPs were immobilized on the surface of Ti implants. Under acidic environment of bacterial biofilm-infection, the CaP shell of MPDA-LUT@CaP NPs was rapidly degraded and released LUT, Ca2+ and PO4 3- from the surface of Ti implant. LUT could effectively inhibit and disperse biofilm. Furthermore, under near-infrared irradiation (NIR), the thermotherapy induced by the photothermal conversion effect of MPDA destroyed the integrity of the bacterial membrane, and synergistically led to protein leakage and a decrease in ATP levels. Combined with photothermal therapy (PTT) and quorum-sensing-inhibition strategy, the surface-functionalized Ti substrate had an antibacterial rate of over 95.59% against Staphylococcus aureus and the elimination rate of the formed biofilm was as high as 90.3%, so as to achieve low temperature and efficient treatment of bacterial biofilm infection. More importantly, the modified Ti implant accelerated the growth of cell and the healing process of bone tissue due to the released Ca2+ and PO4 3-. In summary, this work combined PTT with quorum-sensing-inhibition strategy provides a new idea for surface functionalization of implant for achieving effective antibacterial and osseointegration capabilities.
Collapse
Affiliation(s)
- Jingwei Hu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, China
| | - Yao Ding
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, China
| | - Bailong Tao
- Laboratory Research Center, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Zhang Yuan
- Institute of Medical Research, Northwestern Polytechnical University, Xi'an, 710072, China
| | - Yulu Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, China
| | - Kun Xu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, China
| | - Xuan Li
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, China
| | - Peng liu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, China
| | - Kaiyong Cai
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, China
| |
Collapse
|
47
|
Chen C, Huang B, Liu Y, Liu F, Lee IS. Functional engineering strategies of 3D printed implants for hard tissue replacement. Regen Biomater 2022; 10:rbac094. [PMID: 36683758 PMCID: PMC9845531 DOI: 10.1093/rb/rbac094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 10/20/2022] [Accepted: 10/27/2022] [Indexed: 11/27/2022] Open
Abstract
Three-dimensional printing technology with the rapid development of printing materials are widely recognized as a promising way to fabricate bioartificial bone tissues. In consideration of the disadvantages of bone substitutes, including poor mechanical properties, lack of vascularization and insufficient osteointegration, functional modification strategies can provide multiple functions and desired characteristics of printing materials, enhance their physicochemical and biological properties in bone tissue engineering. Thus, this review focuses on the advances of functional engineering strategies for 3D printed biomaterials in hard tissue replacement. It is structured as introducing 3D printing technologies, properties of printing materials (metals, ceramics and polymers) and typical functional engineering strategies utilized in the application of bone, cartilage and joint regeneration.
Collapse
Affiliation(s)
- Cen Chen
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, PR China
| | - Bo Huang
- College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou 310018, PR China
| | - Yi Liu
- Department of Orthodontics, School of Stomatology, China Medical University, Shenyang 110002, PR China
| | - Fan Liu
- Department of Orthodontics, School of Stomatology, China Medical University, Shenyang 110002, PR China
| | | |
Collapse
|
48
|
Chandra G, Pandey A, Prabha S, Pandey KM. Microstructure, Mechanical, In Vitro Biodegradation, and Antimicrobial Behavior of a Mg-Zn-Ca-Sr/ZrO 2 Composite Prepared Using Powder Metallurgy. ACS APPLIED BIO MATERIALS 2022; 5:5148-5155. [PMID: 36245146 DOI: 10.1021/acsabm.2c00525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Biodegradable materials, especially Mg alloys, have an exceptional advantage over nonbiodegradable materials in orthopedic applications, such as avoiding second surgery for removal/replacement, stress shielding, but not enough mechanical strength, and so forth. By further improving the Mg alloy to get all the remaining required properties, it can be used for better biodegradable implants, which depend adequately on material optimization, processing, and so forth. A Mg-Zn-Ca-Sr/ZrO2 composite has been prepared using powder metallurgy by adding 0, 1, 2, and 3 wt % of ZrO2, which also contains Zn, Ca, and Sr as nutrient elements. Microstructure characterization, as well as mechanical and in vitro biodegradation, have been investigated by hardness, compression, and immersion tests. The highest compressive strength, contraction, and hardness of about 185.6 MPa, 9.5%, and 65.2 HRB are observed in the 2% ZrO2-containing composite, respectively, whereas a minimum biodegradation rate of 2.76 mm/year is observed on the same. The antibiotic sensitivity observations against Staphylococcus aureus suggest that the alloy C3 has superior biological activity against the pathogen which ranks this alloy on top in merit. Overall, Mg-Zn-Ca-Sr/ZrO2 exhibits impressive potential for use as a biodegradable and antibiotic material for orthopedic applications.
Collapse
Affiliation(s)
- Girish Chandra
- Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal462003, India
| | - Ajay Pandey
- Department of Mechanical Engineering, Maulana Azad National Institute of Technology, Bhopal462003, India
| | - Sarit Prabha
- Department of Biological Science and Engineering, Maulana Azad National Institute of Technology, Bhopal462003, India
| | - Khushhali M Pandey
- Department of Biological Science and Engineering, Maulana Azad National Institute of Technology, Bhopal462003, India
| |
Collapse
|
49
|
Lan G, Chu X, Li C, Zhang C, Miao G, Li W, Peng F, Zhao X, Li M. Surface modification of titanium with antibacterial porous N-halamine coating to prevent peri-implant infection. Biomed Mater 2022; 18. [PMID: 36317281 DOI: 10.1088/1748-605x/ac9e33] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Accepted: 10/27/2022] [Indexed: 11/07/2022]
Abstract
Peri-implant infection remains one of the greatest threats to orthopedics. The construction of bone implants with good antibacterial and osteogenic properties is beneficial for reducing the risk of implant-related infections and healing bone defects. In this study, N-halamine coating (namely N-Cl) was grafted onto alkali-heat treated titanium (Ti) using polydopamine to endow Ti-based orthopedic implants with strong bactericidal activity. Surface characterization revealed that the N-Cl coating has porous structure loaded with active chlorine (Cl+). The N-Cl coating also provided micro/nano-structured Ti surfaces with excellent antibacterial ability via transformation between N-H and N-Cl, and approximately 100% disinfection was achieved. Furthermore, the as-prepared N-Cl coating exhibited good biocompatibility and osteogenesis abilityin vitro. These results indicate that applying N-Cl coatings on Ti could prevent and treat peri-implant infections.
Collapse
Affiliation(s)
- Guobo Lan
- Department of Orthopedics, Foshan Fosun Chancheng Hospital, Foshan 528010, People's Republic of China
| | - Xiao Chu
- Medical Research Center, Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, People's Republic of China.,Department of Biomedical Engineering, School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641, People's Republic of China
| | - Chaohui Li
- Department of Orthopedics, Foshan Fosun Chancheng Hospital, Foshan 528010, People's Republic of China
| | - Chi Zhang
- Medical Research Center, Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, People's Republic of China
| | - Guiqiang Miao
- Department of Orthopedics, Foshan Fosun Chancheng Hospital, Foshan 528010, People's Republic of China
| | - Wenyong Li
- Department of Orthopedics, Foshan Fosun Chancheng Hospital, Foshan 528010, People's Republic of China
| | - Feng Peng
- Medical Research Center, Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, People's Republic of China
| | - Xiaodong Zhao
- Department of Orthopedics, Foshan Fosun Chancheng Hospital, Foshan 528010, People's Republic of China
| | - Mei Li
- Medical Research Center, Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, People's Republic of China
| |
Collapse
|
50
|
Jolic M, Sharma S, Palmquist A, Shah FA. The impact of medication on osseointegration and implant anchorage in bone determined using removal torque-A review. Heliyon 2022; 8:e10844. [PMID: 36276721 PMCID: PMC9582727 DOI: 10.1016/j.heliyon.2022.e10844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 08/16/2022] [Accepted: 09/26/2022] [Indexed: 11/06/2022] Open
Abstract
Permanently anchored metal implants are frequently used in dental, craniomaxillofacial, and orthopaedic rehabilitation. The success of such therapies is owed to the phenomenon of osseointegration—the direct connection between the living bone and the implant. The extent of biomechanical anchorage (i.e., physical interlocking between the implant and bone) can be assessed with removal torque (RTQ) measurement. Implant anchorage is strongly influenced by underlying bone quality, involving physicochemical and biological properties such as composition and structural organisation of extracellular matrix, extent of micro-damage, and bone turnover. In this review, we evaluated the impact of various pharmacological agents on osseointegration, from animal experiments conducting RTQ measurements. In addition to substances whose antiresorptive and/or anti-catabolic effects on bone are well-documented (e.g., alendronate, zoledronate, ibandronate, raloxifene, human parathyroid hormone, odanacatib, and the sclerostin monoclonal antibody), positive effects on RTQ have been reported for substances that do not primarily target bone (e.g., aminoguanidine, insulin, losartan, simvastatin, bone morphogenetic protein, alpha-tocopherol, and the combination of silk fibroin powder and platelet-rich fibrin). On the contrary, several substances (e.g., prednisolone, cyclosporin A, cisplatin, and enamel matrix derivative) tend to adversely impact RTQ. While morphometric parameters such as bone-implant contact appear to influence the biomechanical anchorage, increased or decreased RTQ is not always accompanied by corresponding fluctuations in bone-implant contact. This further confirms that factors such as bone quality underpin biomechanical anchorage of metal implants. Several fundamental questions on drug metabolism and bioavailability, drug dosage, animal-to-human translation, and the consequences of treatment interruption remain yet unanswered. Effects of pharmacological agents on osseointegration of metal implants are reviewed. Removal torque is considered as an objective measure of osseointegration. Most investigated anabolic agents are alendronate, zoledronate, and ibandronate. hPTH has a positive effect while cyclosporin A and cisplatin have negative effects. Correction of underlying systemic disorders leads to improved osseointegration.
Collapse
|