Concheri S, Brotto D, Ariano M, Daloiso A, Di Pasquale Fiasca VM, Sorrentino F, Coppadoro B, Trevisi P, Zanoletti E, Franchella S. Intraoperative Measurement of Insertion Speed in Cochlear Implant Surgery: A Preliminary Experience with Cochlear SmartNav. Audiol Res 2024; 14:227-238. [PMID: 38525682 PMCID: PMC10961689 DOI: 10.3390/audiolres14020021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 02/18/2024] [Accepted: 02/19/2024] [Indexed: 03/26/2024] Open
Abstract
OBJECTIVES The objectives were to present the real-time estimated values of cochlear implant (CI) electrode insertion speed (IS) during intraoperative sessions using the Cochlear Nucleus SmartNav System to assess whether this measure affected CI outcomes and to determine whether real-time feedback assists expert surgeons in achieving slow insertion. METHODS The IS was measured in 52 consecutive patients (65 implanted ears) using the CI632 electrode. The IS values were analyzed in relation to procedure repetition over time, NRT ratio, and CI audiological outcomes. RESULTS The average IS was 0.64 mm/s (SD = 0.24); minimum and maximum values were 0.23 and 1.24 mm/s, respectively. The IS significantly decreased with each array insertion by the operator (p = 0.006), and the mean decreased by 24% between the first and last third of procedures; however, this reduction fell within the error range of SmartNav for IS (+/-0.48 mm/s). No correlation was found between IS and the NRT ratio (p = 0.51), pure-tone audiometry (PTA) at CI activation (p = 0.506), and PTA (p = 0.94) or word recognition score (p = 0.231) at last evaluation. CONCLUSIONS The estimated IS reported by SmartNav did not result in a clinically significant reduction in insertion speed or an improvement in CI hearing outcomes. Real-time feedback of IS could potentially be used for training, but its effectiveness requires confirmation through additional studies and more accurate tools. Implementation of IS assessment in clinical practice will enable comparisons between measurement techniques and between manual and robot-assisted insertions. This will help define the optimal IS range to achieve better cochlear implant (CI) outcomes.
Collapse
Affiliation(s)
- Stefano Concheri
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Davide Brotto
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Marzia Ariano
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Antonio Daloiso
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | | | - Flavia Sorrentino
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Beatrice Coppadoro
- Pediatric Hematology Oncology Unit, Department of Woman’s and Child’s Health, Azienda Ospedale-Università di Padova, 35122 Padua, Italy
| | - Patrizia Trevisi
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Elisabetta Zanoletti
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| | - Sebastiano Franchella
- Department of Neurosciences, Section of Otolaryngology, Azienda Ospedale-Università Padova, 35121 Padua, Italy
| |
Collapse
|
2
|
Derieppe A, Gendre A, Bourget-Aguilar K, Bordure P, Michel G. Comparative study of vestibular function preservation in manual versus robotic-assisted cochlear implantation. Cochlear Implants Int 2024; 25:23-27. [PMID: 37985652 DOI: 10.1080/14670100.2023.2271221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2023]
Abstract
OBJECTIVE To compare vestibular outcomes in cochlear implant (CI) surgery, between robotic-assisted insertion of the electrodes versus manual insertion. METHODS We performed a monocentric retrospective study. From March 2021, the robotic system RobOtol© was used for all CI cases. We compared this robotic-assisted insertion group with a manual insertion group of patients who received a CI between July 2020 and March 2021. Primary objective was vestibular outcome. We used objective vestibular function tests: caloric testing, Vestibular Evoked Myogenic Potential (VEMP), and Video Head Impulse Test (VHIT). Secondary objectives were postoperative complications including patient-reported postoperative vertigo. RESULTS We found no statistically significant difference between the two groups in terms of caloric testing, VEMP or VHIT outcomes. In patient-reported outcomes, there was significantly more vertigo in the manual insertion group compared with robotic-assisted insertion. CONCLUSION It is hypothesized that a non-traumatic insertion would cause less vestibular dysfunction postoperatively. Larger prospective studies are required to determine whether robotic-assisted CI insertion has a significant impact on vestibular outcomes in CI surgery.
Collapse
Affiliation(s)
- Arthur Derieppe
- Service d'Oto-Rhino-Laryngologie et chirurgie cervico-faciale, CHU Nantes, Nantes, France
| | - Adrien Gendre
- Service d'Oto-Rhino-Laryngologie et chirurgie cervico-faciale, CHU Nantes, Nantes, France
- National Hearing Implant and Viani Research Center, Beaumont Hospital, Dublin, Ireland; Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Kinnie Bourget-Aguilar
- Service d'Oto-Rhino-Laryngologie et chirurgie cervico-faciale, CHU Nantes, Nantes, France
| | - Philippe Bordure
- Service d'Oto-Rhino-Laryngologie et chirurgie cervico-faciale, CHU Nantes, Nantes, France
| | - Guillaume Michel
- Service d'Oto-Rhino-Laryngologie et chirurgie cervico-faciale, CHU Nantes, Nantes, France
| |
Collapse
|
3
|
Biever A, Kelsall DC, Lupo JE, Haase GM. Evolution of the candidacy requirements and patient perioperative assessment protocols for cochlear implantation. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 152:3346. [PMID: 36586869 DOI: 10.1121/10.0016446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
Cochlear implantation as an approved clinical therapy ushered in an exciting era of innovation for the treatment of hearing loss. The U.S. Food and Drug Administration approved the use of cochlear implants as a treatment option for adults with profound sensorineural hearing loss in 1985. The landscape for treating adults and children with significant hearing loss has changed dramatically over the last three decades. The purpose of this paper is to examine the evolving regulatory process and changes to clinical care. A significant emerging trend in cochlear implantation is the consideration of steroids to preserve hearing during and following surgery. This parallels the quest for hearing preservation in noise-induced hearing disorders, especially considering the current interest in biological drug therapies in this population. The future will likely usher in an era of combination therapeutics utilizing drugs and cochlear implantation. For over 30+ years and following regulatory compliance, the Rocky Mountain Ear Center has developed an extensive candidacy and outcome assessment protocol. This systematic approach evaluates both unaided and aided auditory performance during candidacy stages and post-implantation. Adjunctive measures of cognition and quality-of-life augment the auditory assessment in specific populations. Practical insights into lessons learned have directed further clinical research and have resulted in beneficial changes to clinical care.
Collapse
Affiliation(s)
- Allison Biever
- Rocky Mountain Ear Center, Englewood, Colorado 80113, USA
| | | | - J Eric Lupo
- Rocky Mountain Ear Center, Englewood, Colorado 80113, USA
| | - Gerald M Haase
- University of Colorado, School of Medicine, Aurora, Colorado 80045, USA
| |
Collapse
|
4
|
Robotics and cochlear implant surgery: goals and developments. Curr Opin Otolaryngol Head Neck Surg 2022; 30:314-319. [PMID: 36036531 DOI: 10.1097/moo.0000000000000837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE OF REVIEW Cochlear implantation (CI) is a viable option for patients with severe sensorineural hearing loss. Advances in CI have focused on minimizing cochlear trauma to improve hearing preservation outcomes, and in doing so expanding candidacy to patients with useful cochlear reserve. Robotics holds promise as a potential tool to minimize intracochlear trauma with electrode insertion, improve surgical efficiency, and reduce surgical complications. The purpose of this review is to summarize efforts and advances in the field of robotic-assisted CI. RECENT FINDINGS Work on robotics and CI over the past few decades has explored distinct surgical aspects, including image-based surgical planning and intraoperative guidance, minimally invasive robotic-assisted approaches mainly through percutaneous keyhole direct cochlear access, robotic electrode insertion systems, robotic manipulators, and drilling feedback control through end effector sensors. Feasibility and safety have been established and many devices are undergoing clinical trials for clinical adoption, with some having already achieved approval of national licensing bodies. SUMMARY Significant work has been done over the past two decades that has shown robotic-assisted CI to be feasible and safe. Wider clinical adoption can potentially result in improved hearing preservation and quality of life outcomes to more CI candidates.
Collapse
|
5
|
Deng J, Zhu Q, Zhang K, Xie D, Wu W. Vestibular function in children with cochlear implant: Impact and evaluation. Front Neurol 2022; 13:938751. [PMID: 36090862 PMCID: PMC9449973 DOI: 10.3389/fneur.2022.938751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2022] [Accepted: 08/04/2022] [Indexed: 11/13/2022] Open
Abstract
Over the last 30 years, cochlear implant (CI) has been dedicated to improving the rehabilitation of hearing impairments. However, CI has shown potential detrimental effects on vestibular function. For children, due to atypical symptoms and difficulty in cooperating with vestibular function tests, systematic and objective assessments of vestibular function with CI have been conducted sparsely. This review focuses on the impact of vestibular function in children with CI and summarized the evaluation of vestibular function in children. In addition, some recommended strategies are summarized and proposed.
Collapse
|
6
|
Avasarala VS, Jinka SK, Jeyakumar A. Complications of Cochleostomy Versus Round Window Surgical Approaches: A Systematic Review and Meta-Analysis. Cureus 2022; 14:e25451. [PMID: 35774686 PMCID: PMC9239322 DOI: 10.7759/cureus.25451] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/29/2022] [Indexed: 11/05/2022] Open
|
7
|
Gendre A, Quinn S, Jones H, Hintze J, Simões-Franklin C, Walshe P, Viani L, Glynn F. National study of hearing preservation rates and outcomes after cochlear implantation in Ireland. Cochlear Implants Int 2022; 23:241-248. [PMID: 35418277 DOI: 10.1080/14670100.2022.2061102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVE To study the rate of hearing preservation and outcomes of hearing preservation candidates in a national cochlear implant centre. The HEARRING criteria was used. METHODS All cochlear implant candidates with preserved low frequency pure tone average (PTA) were included. All patients underwent cochlear implantation using a standard 'soft-surgery' technique. PTA was assessed at switch-on, 3, 6, 9 and 12 months postoperatively. The primary outcome was hearing preservation at 12 months. RESULTS Sixty six patients were included in the study between 2015 and 2020. Seventy one ears were implanted including 33 adults and 33 children with 5 bilateral implantations. Mean preoperative PTA was 74.8 dB (range 52.3-92 dB), mean postoperative PTA was 95.3 dB corresponding to a mean shift of 20.5 dB. In the adult population, HP rates were as follows: complete HP in 13%, partial HP in 39.1%, minimal HP in 30.4%, loss of hearing in 17.4%. In the paediatric population: complete HP in 20.7%, partial HP in 51.7%, minimal HP in 13.8% and loss of hearing in 13.8%. After the initial postoperative shift, there was no significant worsening of residual hearing during follow-up between 3 and 12 months. There were no significant prognostic factors for hearing preservation. CONCLUSION Hearing preservation rates using the HEARRING criteria are described. This study will help counselling and decision making in patients eligible for cochlear implantation with hearing preservation. Further studies are required to assess the performances and outcomes of electronatural and electroacoustic stimulation.
Collapse
Affiliation(s)
- Adrien Gendre
- National Hearing Implant and Viani Research Center, Beaumont Hospital, Dublin, Ireland.,Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Sarah Quinn
- Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Holly Jones
- National Hearing Implant and Viani Research Center, Beaumont Hospital, Dublin, Ireland.,Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Justin Hintze
- National Hearing Implant and Viani Research Center, Beaumont Hospital, Dublin, Ireland.,Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Cristina Simões-Franklin
- National Hearing Implant and Viani Research Center, Beaumont Hospital, Dublin, Ireland.,School of Medicine, Trinity College, University of Dublin, Dublin, Ireland
| | - Peter Walshe
- National Hearing Implant and Viani Research Center, Beaumont Hospital, Dublin, Ireland
| | - Laura Viani
- National Hearing Implant and Viani Research Center, Beaumont Hospital, Dublin, Ireland.,Royal College of Surgeons in Ireland, Dublin, Ireland.,School of Medicine, Trinity College, University of Dublin, Dublin, Ireland
| | - Fergal Glynn
- National Hearing Implant and Viani Research Center, Beaumont Hospital, Dublin, Ireland
| |
Collapse
|
8
|
High-speed flat-detector computed tomography for temporal bone imaging and postoperative control of cochlear implants. Neuroradiology 2022; 64:1437-1445. [PMID: 35410396 PMCID: PMC9177478 DOI: 10.1007/s00234-022-02940-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 04/03/2022] [Indexed: 10/30/2022]
Abstract
PURPOSE Flat-detector computed tomography (FD-CT) is the standard for cochlear implant (CI) imaging. FD-CT systems differ in technical characteristics. Our aim was an evaluation of two different FD-CT generations with different protocols and hardware regarding image quality, radiation dose, and scan time. METHODS Two temporal bone specimens (- / + CI = TB0/TB1) were scanned using three different scanners: two FD-CT systems with different scanning protocols (standard FD-CT: 20 s 70 kV, 20 s 109 kV; high-speed FD-CT [HS-FD-CT]: 7 s 109 kV, 9 s 109 kV, 14 s 72 kV) and MS-CT (5 s 120 kV). Acquired datasets were evaluated in consensus reading regarding qualitative and quantitative parameters: addressing CI- and cochlea-specific parameters, cochlea delineation, lamina spiralis ossea visibility, distinction of single CI electrodes, determination of intracochlear implant position, stapes delineation, and mastoidal septation were assessed. Addressing protocol-specific parameters, radiation dose (dose-length-product/DLP), and scan time were assessed. RESULTS Two HS-FD-CT protocols (14 s/9 s) provide higher or equivalent diagnostic information regarding CI- and cochlea-specific parameters compared to both standard FD-CT protocols. The fastest HS-FD-CT protocol (7 s)-providing inferior diagnostic information compared to all other FD-CT protocols-still exceeds MS-CT. The highest DLP was recorded for the 14 s HS-FD-CT protocol (TB1 = 956 mGycm); the lowest DLPs were recorded for the 7 s HS-FD-CT protocol (TB0 = 188 mGycm) and for MS-CT (TB0 = 138 mGycm), respectively. HS-FD-CT allows a significant reduction of scan time compared to standard FD-CT. CONCLUSION High-speed FD-CT improves visualization of temporal bone anatomy and postoperative assessment of CIs by combining excellent image quality, fast scan time, and reasonable radiation exposure.
Collapse
|
9
|
Saha R, Wu K, Bloom RP, Liang S, Tonini D, Wang JP. A review on magnetic and spintronic neurostimulation: challenges and prospects. NANOTECHNOLOGY 2022; 33:182004. [PMID: 35013010 DOI: 10.1088/1361-6528/ac49be] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Accepted: 01/10/2022] [Indexed: 06/14/2023]
Abstract
In the treatment of neurodegenerative, sensory and cardiovascular diseases, electrical probes and arrays have shown quite a promising success rate. However, despite the outstanding clinical outcomes, their operation is significantly hindered by non-selective control of electric fields. A promising alternative is micromagnetic stimulation (μMS) due to the high permeability of magnetic field through biological tissues. The induced electric field from the time-varying magnetic field generated by magnetic neurostimulators is used to remotely stimulate neighboring neurons. Due to the spatial asymmetry of the induced electric field, high spatial selectivity of neurostimulation has been realized. Herein, some popular choices of magnetic neurostimulators such as microcoils (μcoils) and spintronic nanodevices are reviewed. The neurostimulator features such as power consumption and resolution (aiming at cellular level) are discussed. In addition, the chronic stability and biocompatibility of these implantable neurostimulator are commented in favor of further translation to clinical settings. Furthermore, magnetic nanoparticles (MNPs), as another invaluable neurostimulation material, has emerged in recent years. Thus, in this review we have also included MNPs as a remote neurostimulation solution that overcomes physical limitations of invasive implants. Overall, this review provides peers with the recent development of ultra-low power, cellular-level, spatially selective magnetic neurostimulators of dimensions within micro- to nano-range for treating chronic neurological disorders. At the end of this review, some potential applications of next generation neuro-devices have also been discussed.
Collapse
Affiliation(s)
- Renata Saha
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America
| | - Kai Wu
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America
| | - Robert P Bloom
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America
| | - Shuang Liang
- Department of Chemical Engineering and Material Science, University of Minnesota, Minneapolis, MN 55455, United States of America
| | - Denis Tonini
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America
| | - Jian-Ping Wang
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States of America
| |
Collapse
|
10
|
Hartl RMB, Greene NT. Measurement and Mitigation of Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion. Otol Neurotol 2022; 43:174-182. [PMID: 34753876 PMCID: PMC10260290 DOI: 10.1097/mao.0000000000003401] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
HYPOTHESIS High intracochlear pressure transients associated with cochlear implant placement are reduced with smaller, non-styleted arrays, and longer insertion durations. BACKGROUND With increasing focus on hearing preservation during cochlear implant surgery, atraumatic technique is of the utmost importance. Previous studies revealed that high intensity pressure transients can be generated during the insertion of implant electrodes. Resulting acoustic trauma may be one contributing factor to postoperative loss of residual hearing. METHODS Thirty ears in cadaveric specimens were surgically prepared with placement of intracochlear pressure sensors. Sequential implant insertions were made over 10, 30, or 60 seconds using seven randomly ordered electrode styles. Pressures were also measured during common post-insertion electrode manipulations and removal. Measurements were compared between electrode styles and characteristics using analysis of variance (ANOVA) and Pearson correlation. RESULTS Implant insertion and post-insertion manipulations produced high-intensity pressure transients with all electrodes tested, with some measurements exceeding 170 dB peak SPL. Average peak pressures were significantly lower for straight, non-stylet electrodes (p << 0.001). The likelihood of generating transients was lowest with the slowest insertions (p << 0.001). CONCLUSIONS Cochlear implant insertion can generate transients in intralabyrinthine pressure levels equivalent to high intensity, impulsive acoustic stimuli known to cause hearing loss. Although transients were observed in all conditions, exposure may be mitigated by using non-styleted electrodes and slow insertion speeds. Additional surgical manipulations can also produce similar high-pressure events. Results from this investigation suggest that use of non-styleted electrodes, slow but steady insertion speeds, and avoidance of post-insertional manipulations are important to reduce cochlear trauma.
Collapse
Affiliation(s)
- Renee M. Banakis Hartl
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, CO
- Department of Otolaryngology-Head and Neck Surgery, University of Michigan, Ann Arbor, MI
| | - Nathaniel T. Greene
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, CO
| |
Collapse
|
11
|
Skarżyńska MB, Król B, Gos E, Skarżyński PH. Preservation of hearing in partial deafness patients who received two different regimes of corticosteroid therapy following cochlear implantation: one-year observations. BRAZ J PHARM SCI 2022. [DOI: 10.1590/s2175-97902022e20358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/19/2023] Open
Affiliation(s)
- Magdalena Beata Skarżyńska
- Center of Hearing and Speech MEDINCUS, Poland; Institute of Sensory Organs, Poland; Institute of Physiology and Pathology of Hearing, Poland
| | - Bartłomej Król
- World Hearing Center, Poland; Institute of Physiology and Pathology of Hearing, Poland
| | - Elżbieta Gos
- World Hearing Center, Poland; Institute of Physiology and Pathology of Hearing, Poland
| | - Piotr Henryk Skarżyński
- Center of Hearing and Speech MEDINCUS, Poland; Institute of Sensory Organs, Poland; World Hearing Center, Poland; Institute of Physiology and Pathology of Hearing, Poland; Institute of Physiology and Pathology of Hearing, Poland; Institute of Physiology and Pathology of Hearing, Poland; Medical University of Warsaw, Poland
| |
Collapse
|
12
|
Carlyon RP, Goehring T. Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update. J Assoc Res Otolaryngol 2021; 22:481-508. [PMID: 34432222 PMCID: PMC8476711 DOI: 10.1007/s10162-021-00811-5] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 08/02/2021] [Indexed: 12/22/2022] Open
Abstract
Cochlear implants (CIs) are the world's most successful sensory prosthesis and have been the subject of intense research and development in recent decades. We critically review the progress in CI research, and its success in improving patient outcomes, from the turn of the century to the present day. The review focuses on the processing, stimulation, and audiological methods that have been used to try to improve speech perception by human CI listeners, and on fundamental new insights in the response of the auditory system to electrical stimulation. The introduction of directional microphones and of new noise reduction and pre-processing algorithms has produced robust and sometimes substantial improvements. Novel speech-processing algorithms, the use of current-focusing methods, and individualised (patient-by-patient) deactivation of subsets of electrodes have produced more modest improvements. We argue that incremental advances have and will continue to be made, that collectively these may substantially improve patient outcomes, but that the modest size of each individual advance will require greater attention to experimental design and power. We also briefly discuss the potential and limitations of promising technologies that are currently being developed in animal models, and suggest strategies for researchers to collectively maximise the potential of CIs to improve hearing in a wide range of listening situations.
Collapse
Affiliation(s)
- Robert P Carlyon
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK.
| | - Tobias Goehring
- Cambridge Hearing Group, MRC Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, CB2 7EF, UK
| |
Collapse
|
13
|
Abstract
Cochlear implant surgery is a successful procedure for auditory rehabilitation of patients with severe to profound hearing loss. However, cochlear implantation may lead to damage to the inner ear, which decreases residual hearing and alters vestibular function. It is now of increasing interest to preserve residual hearing during this surgery because this is related to better speech, music perception, and hearing in complex listening environments. Thus, different efforts have been tried to reduce cochlear implantation-related injury, including periprocedural glucocorticoids because of their anti-inflammatory properties. Different routes of administration have been tried to deliver glucocorticoids. However, several drawbacks still remain, including their systemic side effects, unknown pharmacokinetic profiles, and complex delivery methods. In the present review, we discuss the role of periprocedural glucocorticoid therapy to decrease cochlear implantation-related injury, thus preserving inner ear function after surgery. Moreover, we highlight the pharmacokinetic evidence and clinical outcomes which would sustain further interventions.
Collapse
|
14
|
Jia H, Wu H. How I do it: Minimally invasive cochlear implantation (with video). Eur Ann Otorhinolaryngol Head Neck Dis 2021; 138 Suppl 3:93-94. [PMID: 34305027 DOI: 10.1016/j.anorl.2021.05.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Revised: 05/03/2021] [Accepted: 05/10/2021] [Indexed: 10/20/2022]
Affiliation(s)
- H Jia
- Department of Otolaryngology Head and Neck Surgery, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiaotong University, No 639 Zhizaoju Road, 200011 Shanghai, China; Shanghai Key Laboratory of Translational Medicine on Ear and Nose Diseases, Shanghai, China; Ear Institute, Shanghai Jiaotong University School of Medicine, No 115 Jingzun Road, 200125 Shanghai, China.
| | - H Wu
- Department of Otolaryngology Head and Neck Surgery, Shanghai Ninth People's Hospital, School of Medicine, Shanghai Jiaotong University, No 639 Zhizaoju Road, 200011 Shanghai, China; Shanghai Key Laboratory of Translational Medicine on Ear and Nose Diseases, Shanghai, China; Ear Institute, Shanghai Jiaotong University School of Medicine, No 115 Jingzun Road, 200125 Shanghai, China.
| |
Collapse
|
15
|
Warnecke A, Prenzler N, Harre J, Köhl U, Gärtner L, Lenarz T, Laner-Plamberger S, Wietzorrek G, Staecker H, Lassacher T, Hollerweger J, Gimona M, Rohde E. First-in-human intracochlear application of human stromal cell-derived extracellular vesicles. J Extracell Vesicles 2021; 10:e12094. [PMID: 34136108 PMCID: PMC8178433 DOI: 10.1002/jev2.12094] [Citation(s) in RCA: 46] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 03/15/2021] [Accepted: 04/22/2021] [Indexed: 12/20/2022] Open
Abstract
Extracellular vesicles (EVs) derived from the secretome of human mesenchymal stromal cells (MSC) contain numerous factors that are known to exert anti‐inflammatory effects. MSC‐EVs may serve as promising cell‐based therapeutics for the inner ear to attenuate inflammation‐based side effects from cochlear implantation which represents an unmet clinical need. In an individual treatment performed on a ‘named patient basis’, we intraoperatively applied allogeneic umbilical cord‐derived MSC‐EVs (UC‐MSC‐EVs) produced according to good manufacturing practice. A 55‐year‐old patient suffering from Menière's disease was treated with intracochlear delivery of EVs prior to the insertion of a cochlear implant. This first‐in‐human use of UC‐MSC‐EVs demonstrates the feasibility of this novel adjuvant therapeutic approach. The safety and efficacy of intracochlear EV‐application to attenuate side effects of cochlea implants have to be determined in controlled clinical trials.
Collapse
Affiliation(s)
- Athanasia Warnecke
- Department of Otorhinolaryngology, Head and Neck Surgery Hannover Medical School Hannover Germany
| | - Nils Prenzler
- Department of Otorhinolaryngology, Head and Neck Surgery Hannover Medical School Hannover Germany
| | - Jennifer Harre
- Department of Otorhinolaryngology, Head and Neck Surgery Hannover Medical School Hannover Germany
| | - Ulrike Köhl
- Institute for Cellular Therapeutics Hannover and Institute of Clinical Immunology Hannover Medical School University of Leipzig as well as Fraunhofer Institute for Cell Therapy and Immunology (IZI) Leipzig Germany
| | - Lutz Gärtner
- Department of Otorhinolaryngology, Head and Neck Surgery Hannover Medical School Hannover Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Head and Neck Surgery Hannover Medical School Hannover Germany
| | - Sandra Laner-Plamberger
- Department of Transfusion Medicine University Hospital Salzburger Landeskliniken GesmbH (SALK) and Paracelsus Medical University (PMU) Salzburg Austria
| | - Georg Wietzorrek
- Institute of Molecular and Cellular Pharmacology Medical University of Innsbruck Innsbruck Austria
| | - Hinrich Staecker
- Department of Otolaryngology Head and Neck Surgery University of Kansas School of Medicine Kansas City Kansas USA
| | - Teresa Lassacher
- GMP Unit Spinal Cord Injury & Tissue Regeneration Centre Salzburg (SCI-TReCS) Paracelsus Medical University (PMU) Salzburg Austria.,Research Program Nanovesicular Therapeutics Paracelsus Medical University (PMU) Salzburg Austria
| | - Julia Hollerweger
- GMP Unit Spinal Cord Injury & Tissue Regeneration Centre Salzburg (SCI-TReCS) Paracelsus Medical University (PMU) Salzburg Austria.,Research Program Nanovesicular Therapeutics Paracelsus Medical University (PMU) Salzburg Austria
| | - Mario Gimona
- Department of Transfusion Medicine University Hospital Salzburger Landeskliniken GesmbH (SALK) and Paracelsus Medical University (PMU) Salzburg Austria.,GMP Unit Spinal Cord Injury & Tissue Regeneration Centre Salzburg (SCI-TReCS) Paracelsus Medical University (PMU) Salzburg Austria.,Research Program Nanovesicular Therapeutics Paracelsus Medical University (PMU) Salzburg Austria.,Research and Transfer Centre for Extracellular Vesicle Theralytic Technologies Salzburg Austria
| | - Eva Rohde
- Department of Transfusion Medicine University Hospital Salzburger Landeskliniken GesmbH (SALK) and Paracelsus Medical University (PMU) Salzburg Austria.,GMP Unit Spinal Cord Injury & Tissue Regeneration Centre Salzburg (SCI-TReCS) Paracelsus Medical University (PMU) Salzburg Austria.,Research and Transfer Centre for Extracellular Vesicle Theralytic Technologies Salzburg Austria
| |
Collapse
|
16
|
Spectral resolution and speech perception after cochlear implantation using the round window versus cochleostomy technique. The Journal of Laryngology & Otology 2021; 135:513-517. [PMID: 33958008 DOI: 10.1017/s0022215121001183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE To evaluate the spectral resolution achieved with a cochlear implant in users who were implanted using round window route electrode insertion versus a traditional cochleostomy technique. METHODS Twenty-six patients were classified into two groups according to the surgical approach: one group (n = 13) underwent cochlear implantation via the round window technique and the other group (n = 13) underwent surgery via cochleostomy. RESULTS A statistically significant difference was found in spectral ripple discrimination scores between the round window and cochleostomy groups. The round window group performed almost two times better than the cochleostomy group. Differences between Turkish matrix sentence test scores were not statistically significant. CONCLUSION The spectral ripple discrimination scores of patients who had undergone round window cochlear implant electrode insertion were superior to those of patients whose cochlear implants were inserted using a classical cochleostomy technique.
Collapse
|
17
|
Endoscope-assisted Partial Cochlectomy for Intracochlear Schwannoma With Simultaneous Cochlear Implantation: A Case Report. Otol Neurotol 2021; 41:334-338. [PMID: 31923084 DOI: 10.1097/mao.0000000000002539] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Intralabyrinthine schwannomas are a small subset of vestibular schwannomas which originate within the labyrinthine structures. Management typically consists of watch-and-wait strategies given that surgical intervention will sacrifice hearing. Endoscopic resection of primary intracochlear schwannoma with simultaneous cochlear implantation for a patient with progressive hearing loss and debilitating tinnitus is described. PATIENT A 56-year-old male presenting with asymmetric left sensorineural hearing loss (SNHL) was diagnosed with intracochlear schwannoma on MRI. INTERVENTION Surgery was indicated due to tumor growth on serial imaging, worsening SNHL, and severe tinnitus. Partial cochlectomy was performed via transcanal endoscopic approach. Cochlear implantation via mastoidectomy and posterior tympanotomy was simultaneously performed with a CI512 Contour Advanced implant (Cochlear, Sydney, Australia). MAIN OUTCOME MEASURES Post partial cochlectomy speech performance. RESULTS Preoperative audiometry showed left profound SNHL with 20% speech recognition score despite maximal amplification. Speech perception testing 5 months postoperatively demonstrated good unilateral discrimination when testing the implanted ear alone (BKB sentences 66%, CUNY sentences 79%), open-set comprehension, and excellent binaural performance. CONCLUSION The endoscope offers an additional viable approach to the otic capsule for the removal of intracochlear schwannoma and good audiologic outcomes can be achieved with simultaneous cochlear implantation even after partial cochlectomy.
Collapse
|
18
|
Zheng Z, Zeng S, Liu C, Li W, Zhao L, Cai C, Nie G, He Y. The DNA methylation inhibitor RG108 protects against noise-induced hearing loss. Cell Biol Toxicol 2021; 37:751-771. [PMID: 33723744 PMCID: PMC8490244 DOI: 10.1007/s10565-021-09596-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 02/22/2021] [Indexed: 11/29/2022]
Abstract
Background Noise-induced hearing loss represents a commonly diagnosed type of hearing disability, severely impacting the quality of life of individuals. The current work is aimed at assessing the effects of DNA methylation on noise-induced hearing loss. Methods Blocking DNA methyltransferase 1 (DNMT1) activity with a selective inhibitor RG108 or silencing DNMT1 with siRNA was used in this study. Auditory brainstem responses were measured at baseline and 2 days after trauma in mice to assess auditory functions. Whole-mount immunofluorescent staining and confocal microcopy of mouse inner ear specimens were performed to analyze noise-induced damage in cochleae and the auditory nerve at 2 days after noise exposure. Results The results showed that noise exposure caused threshold elevation of auditory brainstem responses and cochlear hair cell loss. Whole-mount cochlea staining revealed a reduction in the density of auditory ribbon synapses between inner hair cells and spiral ganglion neurons. Inhibition of DNA methyltransferase activity via a non-nucleoside specific pharmacological inhibitor, RG108, or silencing of DNA methyltransferase-1 with siRNA significantly attenuated ABR threshold elevation, hair cell damage, and the loss of auditory synapses. Conclusions This study suggests that inhibition of DNMT1 ameliorates noise-induced hearing loss and indicates that DNMT1 may be a promising therapeutic target. Graphical abstract Graphical Headlights • RG108 protected against noise-induced hearing loss • RG108 administration protected against noise-induced hair cell loss and auditory neural damage. • RG108 administration attenuated oxidative stress-induced DNA damage and subsequent apoptosis-mediated cell loss in the cochlea after noise exposure. ![]()
Supplementary Information The online version contains supplementary material available at 10.1007/s10565-021-09596-y.
Collapse
Affiliation(s)
- Zhiwei Zheng
- ENT institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Shanghai, 200031, China
- NHC Key Laboratory of Hearing Medicine (Fudan University), Shanghai, 200031, China
| | - Shan Zeng
- ENT institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Shanghai, 200031, China
- NHC Key Laboratory of Hearing Medicine (Fudan University), Shanghai, 200031, China
| | - Chang Liu
- ENT institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Shanghai, 200031, China
- NHC Key Laboratory of Hearing Medicine (Fudan University), Shanghai, 200031, China
| | - Wen Li
- ENT institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Shanghai, 200031, China
- NHC Key Laboratory of Hearing Medicine (Fudan University), Shanghai, 200031, China
| | - Liping Zhao
- ENT institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Shanghai, 200031, China
- NHC Key Laboratory of Hearing Medicine (Fudan University), Shanghai, 200031, China
| | - Chengfu Cai
- Department of Otorhinolaryngology Head and Neck Surgery, The First Affiliated Hospital, School of Medicine, Xiamen University, Xiamen, 361003, People's Republic of China
| | - Guohui Nie
- Department of Otolaryngology and Institute of Translational Medicine, Shenzhen Second People's Hospital/the First Affiliated Hospital of Shenzhen University Health Science Center, Shenzhen, 518035, China.
| | - Yingzi He
- ENT institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Shanghai, 200031, China.
- NHC Key Laboratory of Hearing Medicine (Fudan University), Shanghai, 200031, China.
| |
Collapse
|
19
|
Eisenhut F, Lang S, Taha L, Hoelter P, Wiesmueller M, Uder M, Iro H, Doerfler A, Hornung J. Identification of anatomic risk factors for scalar translocation in cochlear implant patients. Z Med Phys 2021; 31:254-264. [PMID: 33648794 DOI: 10.1016/j.zemedi.2021.01.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Revised: 12/02/2020] [Accepted: 01/05/2021] [Indexed: 10/22/2022]
Abstract
AIM Microanatomical evaluation of cochlear implant (CI) patients to identify anatomical risk factors for a scalar translocation. METHODS CI patients with both a regular scala tympani spiralization (group A) and a scalar translocation (group B) were identified via postoperative flat-detector computed tomography (FD-CT). Then, the corresponding preoperative multislice computed tomography (MS-CT) and postoperative FD-CT datasets were assessed: First, the cochleae were separated in 6 segments of 45° each. Next, quantitative (cochlea height, length, depth, cochlear duct diameter [CD] per segment; percentual tapering of the CD per segment named cochlear geometry index [CGI]) and qualitative (identifiability of the CI model; CI-integrity; intracochlear array position) parameters were evaluated and compared for both groups. Receiver-operating-characteristics (ROC) analysis was performed for the CGI. RESULTS In total, 40 preoperative MS-CT and postoperative FD-CT datasets (nA=20; nB=20) were analysed. Model "CI 512" was successfully identified and CI-integrity has been confirmed in all cases. Quantitative analysis showed a significant difference of both the CD at 0° (CDA0°= 2.06± 0.23mm; CDB0°= 2.19±0.18mm; p0°= 0.04) and the CGI of the first segment (CGIA0°-45°= 18.87±6.04%; CGIB0°-45°= 28.89±8.58%; p0°-45°= 0.0001). For all other 5 cochlear segments there was no significant difference of CD and CGI; there was no significant difference of external cochlea diameters. The area under the curve (AUC) of the CGI0-45° was 0.864 with 24.50° as the optimal cut-off value to discriminate patients with a scala tympani spiralization and a scalar translocation. CGI0-45° of> 24.50° allowed the correct identification of 85% of patients with a scalar translocation. CONCLUSION CI insertion trauma is associated with a significantly higher narrowing of the proximal basal cochlea turn (BCT). The CGI as percentual tapering of the BCT turned out as reliable, clinically applicable parameter for identification of patients with an increased risk for a scalar translocation.
Collapse
Affiliation(s)
- Felix Eisenhut
- Department of Neuroradiology, University Hospital Erlangen, Schwabachanlage 6, 91054, Erlangen, Germany.
| | - Stefan Lang
- Department of Neuroradiology, University Hospital Erlangen, Schwabachanlage 6, 91054, Erlangen, Germany
| | - Lava Taha
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Waldstraße 1, 91054, Erlangen, Germany
| | - Philip Hoelter
- Department of Neuroradiology, University Hospital Erlangen, Schwabachanlage 6, 91054, Erlangen, Germany
| | - Marco Wiesmueller
- Institute of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Maximiliansplatz 3, 91054, Erlangen, Germany
| | - Heinrich Iro
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Waldstraße 1, 91054, Erlangen, Germany
| | - Arnd Doerfler
- Department of Neuroradiology, University Hospital Erlangen, Schwabachanlage 6, 91054, Erlangen, Germany
| | - Joachim Hornung
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Erlangen, Waldstraße 1, 91054, Erlangen, Germany
| |
Collapse
|
20
|
Riemann C, Sudhoff H, Todt I. Effect of Underwater Insertion on Intracochlear Pressure. Front Surg 2020; 7:546779. [PMID: 33425980 PMCID: PMC7793869 DOI: 10.3389/fsurg.2020.546779] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2020] [Accepted: 10/28/2020] [Indexed: 11/17/2022] Open
Abstract
Background: The importance of intracochlear pressure during cochlear electrode insertion for the preservation of residual hearing has been widely discussed. Various aspects of pre-insertional, intra-insertional, and post-insertional relevant conditions affect intracochlear pressure. The fluid situation at the round window during electrode insertion has been shown to be an influential factor. Aims/Objectives: The aim of the study was to compare various insertion techniques in terms of the fluid situation at the round window. Material and Methods: We performed insertion of cochlear implant electrodes in a curled artificial cochlear model. We placed and fixed the pressure sensor at the tip of the cochlea. In parallel to the insertions, we evaluated the maximum amplitude of intracochlear pressure under four different fluid conditions at the round window: (1) hyaluronic acid; (2) moisturized electrode, dry middle ear; (3) middle ear filled with fluid (underwater); and (4) moisturized electrode, wet middle ear, indirectly inserted. Results: We observed that the insertional intracochlear pressure is dependent on the fluid situation in front of the round window. The lowest amplitude changes were observed for the moisturized electrode indirectly inserted in a wet middle ear (0.13 mmHg ± 0.07), and the highest values were observed for insertion through hyaluronic acid in front of the round window (0.64 mmHg ± 0.31). Conclusions: The fluid state in front of the round window influences the intracochlear pressure value during cochlear implant electrode insertion in our model. Indirect insertion of a moisturized electrode through a wet middle ear experimentally generated the lowest pressure values. Hyaluronic acid in front of the round window leads to high intracochlear pressure in our non-validated artificial model.
Collapse
Affiliation(s)
- Conrad Riemann
- Department of Otolaryngology, Head and Neck Surgery, Bielefeld University, Campus Mitte, Klinikum Bielefeld, Bielefeld, Germany
| | - Holger Sudhoff
- Department of Otolaryngology, Head and Neck Surgery, Bielefeld University, Campus Mitte, Klinikum Bielefeld, Bielefeld, Germany
| | - Ingo Todt
- Department of Otolaryngology, Head and Neck Surgery, Bielefeld University, Campus Mitte, Klinikum Bielefeld, Bielefeld, Germany
| |
Collapse
|
21
|
Impedance Values Do Not Correlate With Speech Understanding in Cochlear Implant Recipients. Otol Neurotol 2020; 41:e1029-e1034. [PMID: 32675728 DOI: 10.1097/mao.0000000000002743] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To evaluate a possible correlation between impedance values and speech perception after cochlear implantation. STUDY DESIGN Retrospective chart review. SETTING Tertiary referral center. PATIENTS AND INTERVENTION All patients implanted with a MedEl Flex28 device in our department with complete audiometric data (Freiburger monosyllabic testing at 65 dB, Hochmaier-Schulz-Moser testing in quiet and in 10 dB noise) and impedance measurements at the 1-year refitting appointment were enrolled in this study. Further inclusion criteria were age > 17 years, native speakers, and no use of electric-acoustic-stimulation. MAIN OUTCOME MEASURES Mean values for impedances were calculated over all electrode contacts and separately for basal, medial, and apical regions. These data were correlated statistically (Pearson's correlation) with speech testing results. Furthermore, groups of patients with extreme values were built and compared against each other and against the rest of the collective. RESULTS Impedance values did not correlate significantly with speech performance in any of the audiometric tests neither for all electrode contacts nor for specific clusters of contacts. Patients with the lowest impedances did not perform statistically different than patients with the highest impedances in any condition. CONCLUSION To our knowledge, this is the first data on a possible correlation between impedances and speech perception. The extent of the impedances as a benchmark for a good performance in speech discrimination tests could not be verified. Further prospective studies, possibly with more precise diagnostic tools, should be carried out to define the value of impedance measurements for cochlear implantation provision.
Collapse
|
22
|
Prenzler NK, Salcher R, Lenarz T, Gaertner L, Warnecke A. Dose-Dependent Transient Decrease of Impedances by Deep Intracochlear Injection of Triamcinolone With a Cochlear Catheter Prior to Cochlear Implantation-1 Year Data. Front Neurol 2020; 11:258. [PMID: 32390924 PMCID: PMC7194199 DOI: 10.3389/fneur.2020.00258] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Accepted: 03/20/2020] [Indexed: 02/02/2023] Open
Abstract
Administration of low-dose steroids via a catheter inserted into the cochlea to apply pharmaceuticals to more apical regions was previously shown not to be sufficient for long-term reduction of electrode impedances. The aim of the present study was to investigate the effect of intra-cochlear high-dose triamcinolone application on impedances in cochlear implant recipients. Patients received low-dose (4 mg/ml; n = 5) or high-dose (20 mg/ml; n = 5) triamcinolone via a cochlear catheter just prior to the insertion of a Med-El Flex28 electrode. Impedances were measured at defined time points from intra-operatively up to 12 months after first fitting and retrospectively compared with a control group (no steroid application). Patients who received a high-dose application of crystalloid triamcinolone showed significantly reduced impedances in the first fitting measurements compared to the control group. This effect was no longer detectable in patients of the low-dose group at that time. Looking at the different regions of the electrode, the impedance values were lowered significantly only at the basal and medial contacts. At later time points, there were no significant differences between any of the groups. This is the first study to demonstrate a dose-dependent reduction of impedances by deep intra-cochlear injection of triamcinolone in cochlear implant patients. With a high-dose, single application of triamcinolone using a cochlear catheter prior to insertion of a Flex28 electrode, the impedances can be significantly reduced up to and including the first fitting. Although the effect was longer lasting than when compared to low-dose triamcinolone, it was also not permanent.
Collapse
Affiliation(s)
- Nils K Prenzler
- Department of Otorhinolaryngology, Head and Neck Surgery, Hanover Medical School, Hanover, Germany.,Cluster of Excellence "Hearing4all2.0" of the German Research Foundation, Hanover, Germany
| | - Rolf Salcher
- Department of Otorhinolaryngology, Head and Neck Surgery, Hanover Medical School, Hanover, Germany.,Cluster of Excellence "Hearing4all2.0" of the German Research Foundation, Hanover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Head and Neck Surgery, Hanover Medical School, Hanover, Germany.,Cluster of Excellence "Hearing4all2.0" of the German Research Foundation, Hanover, Germany
| | - Lutz Gaertner
- Department of Otorhinolaryngology, Head and Neck Surgery, Hanover Medical School, Hanover, Germany.,Cluster of Excellence "Hearing4all2.0" of the German Research Foundation, Hanover, Germany
| | - Athanasia Warnecke
- Department of Otorhinolaryngology, Head and Neck Surgery, Hanover Medical School, Hanover, Germany.,Cluster of Excellence "Hearing4all2.0" of the German Research Foundation, Hanover, Germany
| |
Collapse
|
23
|
Surgical complications of cochlear implantation: a 25-year retrospective analysis of cases in a tertiary academic center. Eur Arch Otorhinolaryngol 2020; 277:1917-1923. [PMID: 32185500 DOI: 10.1007/s00405-020-05916-w] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Accepted: 03/06/2020] [Indexed: 10/24/2022]
Abstract
PURPOSE Despite the advances made in cochlear implantation techniques, the associated complication rates are still high. Here, we aimed to analyze cases, with extensive follow-up data, associated with a large sample of patients to identify complications related to cochlear implants and to present our surgical experience and the technique that we used in order to follow surgical rules/medical purpose to avoid any complications. METHODS We retrospectively examined cases involving 2597 patients (1342 males; 1255 females; age 1-88 years) who underwent cochlear implantation procedures between November 1995 and July 2019, and we classified complications as minor and major. RESULTS The mean age at the time of implantation was 6.48 (Min: 1/Max: 88) years. The cause of deafness was congenital in 76.5% of the patients and acquired in 16.8%. The overall rate of complications in the study was 3.7% (n = 97). The minor and major complication rates were 3.0 and 0.7, respectively. Further, while the most common minor complication we encountered was vertigo, the most common major complication was implant extrusion. CONCLUSION Fixing the cochlear implant receiver-stimulator with the bone-recess technique and sealing the posterior tympanotomy site with a piece of muscle in order to follow surgical rules/medical purpose to avoid any complications. Following the insertion of the electrode into the cochlea, the muscle closure of the cochleostomy site or the round window restores the original anatomy and in order to follow surgical rules/medical purpose to avoid any complications. We have developed this highly effective technique with years of experience and have not had a major surgical complication in 5 years.
Collapse
|
24
|
Ordonez F, Riemann C, Mueller S, Sudhoff H, Todt I. Dynamic intracochlear pressure measurement during cochlear implant electrode insertion. Acta Otolaryngol 2019; 139:860-865. [PMID: 31298591 DOI: 10.1080/00016489.2019.1640391] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Background: Electrode insertion into the cochlea can cause significant pressure changes inside the cochlea with assumed effects on the cochlea's functionality regarding residual hearing. Model-based intracochlear pressure (ICP) changes were performed statically at the cochlear helix. Aims/objectives: The aim of this study was to observe dynamic pressure measurements during electrode insertion directly at the cochlear implant electrode. Material and methods: The experiments were performed in an uncurled cochlear model that contained a volume value equivalent to a full cochlea. A microfibre pressure sensor was attached at one of two positions on a cochlear implant electrode and inserted under different insertional conditions. Results: We observed the ICP increase depending on the insertional depth. A sensor-position-specific pressure change is insertional-depth dependent. Interval insertion did not lead to a lower peak insertional ICP. Conclusions and significance: In contrast to the static pressure-sensor measurement in the artificial model's helix, a dynamic measurement directly at the electrode shows the pressure profile to increase based on the insertional depth. A mechanical traumatic relevance of the observed pressure values cannot be fully excluded.
Collapse
Affiliation(s)
- F. Ordonez
- Department of Otolaryngology, Head and Neck Surgery, Klinikum Bielefeld, Bielefeld, Germany
| | - C. Riemann
- Department of Otolaryngology, Head and Neck Surgery, Klinikum Bielefeld, Bielefeld, Germany
| | - S. Mueller
- Department of Otolaryngology, Head and Neck Surgery, Klinikum Bielefeld, Bielefeld, Germany
| | - H. Sudhoff
- Department of Otolaryngology, Head and Neck Surgery, Klinikum Bielefeld, Bielefeld, Germany
| | - I. Todt
- Department of Otolaryngology, Head and Neck Surgery, Klinikum Bielefeld, Bielefeld, Germany
| |
Collapse
|
25
|
Banakis Hartl RM, Kaufmann C, Hansen MR, Tollin DJ. Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion: Effect of Micro-mechanical Control on Limiting Pressure Trauma. Otol Neurotol 2019; 40:736-744. [PMID: 31192901 PMCID: PMC6578873 DOI: 10.1097/mao.0000000000002164] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
HYPOTHESIS Use of micro-mechanical control during cochlear implant (CI) electrode insertion will result in reduced number and magnitude of pressure transients when compared with standard insertion by hand. INTRODUCTION With increasing focus on hearing preservation during CI surgery, atraumatic electrode insertion is of the utmost importance. It has been established that large intracochlear pressure spikes can be generated during the insertion of implant electrodes. Here, we examine the effect of using a micro-mechanical insertion control tool on pressure trauma exposures during implantation. METHODS Human cadaveric heads were surgically prepared with an extended facial recess. Electrodes from three manufacturers were placed both by using a micro-mechanical control tool and by hand. Insertions were performed at three different rates: 0.2 mm/s, 1.2 mm/s, and 2 mm/s (n = 20 each). Fiber-optic sensors measured pressures in scala vestibuli and tympani. RESULTS Electrode insertion produced pressure transients up to 174 dB SPL. ANOVA revealed that pressures were significantly lower when using the micro-mechanical control device compared with insertion by hand (p << 0.001). No difference was noted across electrode type or speed. Chi-square analysis showed a significantly lower proportion of insertions contained pressure spikes when the control system was used (p << 0.001). CONCLUSION Results confirm previous data that suggest CI electrode insertion can cause pressure transients with intensities similar to those elicited by high-level sounds. Results suggest that the use of a micro-mechanical insertion control system may mitigate trauma from pressure events, both by reducing the amplitude and the number of pressure spikes resulting from CI electrode insertion.
Collapse
Affiliation(s)
- Renee M Banakis Hartl
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado
| | - Christopher Kaufmann
- Department of Otolaryngology - Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Marlan R Hansen
- Department of Otolaryngology - Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Daniel J Tollin
- Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado
- Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado
| |
Collapse
|
26
|
Jang JH, Choo OS, Kim H, Yi Park H, Choung YH. Round window membrane visibility related to success of hearing preservation in cochlear implantation. Acta Otolaryngol 2019; 139:618-624. [PMID: 31066597 DOI: 10.1080/00016489.2019.1609701] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Objectives: This study was designed to evaluate the relationship between the degree of round window membrane (RWM) exposure and hearing outcome. Materials and methods: Forty-six ears with cochlear implantation (CI) were enrolled. The degree of RWM exposure was divided into Grade I (<25%), Grade II (25-50%), and Grade III (>50%). The hearing outcomes were evaluated at 1.5 and 12 months postoperatively. Results: Twenty-seven ears were Grade I, 13 were Grade II, and 6 were Grade III. RW approach was used in all ears of Grades II and III and 20 ears of Grade I and cochleostomy was used in 7 ears of Grade I. The pattern of bony overhang was multidirectional in 41 ears. Threshold shift significantly decreased proportional to the increase of RWM exposure after CI. The mean RWM exposure was 32.1 ± 24.4% in ears with more than partial preservation (n = 17), and 13.3 ± 11.7% in the other ears (n = 6) at 12 months post-CI (p = .061). Age at CI differed significantly between ears that had more than partial preservation and the other ears at 1.5 months post-CI. Conclusions and significance: Degree of RWM exposure and age at CI might be factors predicting hearing outcome after CI using the RW approach.
Collapse
Affiliation(s)
- Jeong Hun Jang
- Department of Otolaryngology, Ajou University School of Medicine, Suwon, Korea
| | - Oak-Sung Choo
- Department of Otolaryngology, Ajou University School of Medicine, Suwon, Korea
| | - Hantai Kim
- Department of Otolaryngology, Ajou University School of Medicine, Suwon, Korea
| | - Hun Yi Park
- Department of Otolaryngology, Ajou University School of Medicine, Suwon, Korea
| | - Yun-Hoon Choung
- Department of Otolaryngology, Ajou University School of Medicine, Suwon, Korea
- Ajou University Graduate School of Medicine, Bk21 Plus Research Center for Biomedical Sciences, Suwon, Korea
| |
Collapse
|
27
|
Incerti PV, Ching TY, Cowan R. The effect of cross-over frequency on binaural hearing performance of adults using electric-acoustic stimulation. Cochlear Implants Int 2019; 20:190-206. [PMID: 30880646 DOI: 10.1080/14670100.2019.1590499] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Objective: To investigate the effect of varying cross-over frequency (CF) settings for electric-acoustic (EA) stimulation in one ear combined with acoustic (A) hearing in the opposite ear on binaural speech perception, localization and functional performance in real life. Methods: Performance with three different CF settings set according to audiometric-based criterion were compared, following a four week familiarisation period with each, in ten adult cochlear implant recipients with residual hearing in both ears. On completion of all trials participants selected their preferred CF setting. Results: On average, CF settings did not have a significant effect on performance scores. However, higher ratings on device usage were associated with the preferred CF settings. Conclusion: Individuals who use EA + A stimulation may benefit from access to different CF settings to achieve maximal device usage.
Collapse
Affiliation(s)
- Paola V Incerti
- a National Acoustic Laboratories , Australian Hearing , Sydney , NSW 2109 , Australia.,b The Hearing CRC , Melbourne , Australia.,c Department of Audiology and Speech Pathology , The University of Melbourne , Melbourne , Australia
| | - Teresa Yc Ching
- a National Acoustic Laboratories , Australian Hearing , Sydney , NSW 2109 , Australia.,b The Hearing CRC , Melbourne , Australia
| | - Robert Cowan
- b The Hearing CRC , Melbourne , Australia.,c Department of Audiology and Speech Pathology , The University of Melbourne , Melbourne , Australia
| |
Collapse
|
28
|
Sanderson AP, Rogers ETF, Verschuur CA, Newman TA. Exploiting Routine Clinical Measures to Inform Strategies for Better Hearing Performance in Cochlear Implant Users. Front Neurosci 2019; 12:1048. [PMID: 30697145 PMCID: PMC6340939 DOI: 10.3389/fnins.2018.01048] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Accepted: 12/24/2018] [Indexed: 11/21/2022] Open
Abstract
Neuroprostheses designed to interface with the nervous system to replace injured or missing senses can significantly improve a patient's quality of life. The challenge remains to provide implants that operate optimally over several decades. Changes in the implant-tissue interface may precede performance problems. Tools to identify and characterize such changes using existing clinical measures would be highly valuable. Modern cochlear implant (CI) systems allow easy and regular measurements of electrode impedance (EI). This measure is routinely performed as a hardware integrity test, but it also allows a level of insight into the immune-mediated response to the implant, which is associated with performance outcomes. This study is a 5-year retrospective investigation of MED-EL CI users at the University of Southampton Auditory Implant Service including 176 adult ears (18-91) and 74 pediatric ears (1-17). The trend in EI in adults showed a decrease at apical electrodes. An increase was seen at the basal electrodes which are closest to the surgery site. The trend in the pediatric cohort was increasing EI over time for nearly all electrode positions, although this group showed greater variability and had a smaller sample size. We applied an outlier-labeling rule to statistically identify individuals that exhibit raised impedance. This highlighted 14 adult ears (8%) and 3 pediatric ears (5%) with impedance levels that deviated from the group distribution. The slow development of EI suggests intra-cochlear fibrosis and/or osteogenesis as the underlying mechanism. The usual clinical intervention for extreme impedance readings is to deactivate the relevant electrode. Our findings highlight some interesting clinical contradictions: some cases with raised (but not extreme) impedance had not prompted an electrode deactivation; and many cases of electrode deactivation had been informed by subjective patient reports. This emphasizes the need for improved objective evidence to inform electrode deactivations in borderline cases, for which our outlier-labeling approach is a promising candidate. A data extraction and analysis protocol that allows ongoing and automated statistical analysis of routinely collected data could benefit both the CI and wider neuroprosthetics communities. Our approach provides new tools to inform practice and to improve the function and longevity of neuroprosthetic devices.
Collapse
Affiliation(s)
- Alan P. Sanderson
- Institute of Sound and Vibration Research, Faculty of Engineering and the Environment, University of Southampton, Southampton, United Kingdom
| | - Edward T. F. Rogers
- Institute for Life Sciences and Optoelectronics Research Centre, University of Southampton, Southampton, United Kingdom
| | - Carl A. Verschuur
- Auditory Implant Service, Faculty of Engineering and the Environment, University of Southampton, Southampton, United Kingdom
| | - Tracey A. Newman
- Clinical Neurosciences, Institute for Life Sciences, Faculty of Medicine, University of Southampton, Southampton, United Kingdom
| |
Collapse
|
29
|
Single Intravenous High Dose Administration of Prednisolone Has No Influence on Postoperative Impedances in the Majority of Cochlear Implant Patients. Otol Neurotol 2018; 39:e1002-e1009. [DOI: 10.1097/mao.0000000000002033] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
30
|
Colin V, Bertholon P, Roy S, Karkas A. Impact of cochlear implantation on peripheral vestibular function in adults. Eur Ann Otorhinolaryngol Head Neck Dis 2018; 135:417-420. [PMID: 30431000 DOI: 10.1016/j.anorl.2018.10.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
OBJECTIVE Cochlear implantation may have a detrimental effect on vestibular function and residual hearing. Our goal was to investigate the impact of cochlear implantation on peripheral vestibular function and the symptomatology that ensues. MATERIAL AND METHODS A prospective observational study included all adults undergoing cochlear implantation by the same operator between July 2014 and December 2015, with pre- and postoperative (4 months) neurovestibular balance examination comprising a questionnaire and clinical tests [head impulse test (HIT), head-shaking test (HST), skull vibration test (SVT)] and instrumental tests [caloric test of the lateral semicircular canal and cervical vestibular-evoked myogenic potentials (cVEMP)]. RESULTS Twenty-two patients were included, with a mean age of 62 years and sex-ratio of 1.2. Before implantation, 50% of subjects (n=11) reported at least one episode of vertigo associated with balance disorder during their life. After implantation, there were 11 cases of vertigo but only one patient described persistent discomfort related to vertigo 4 months after surgery. Patients with impaired vestibular function after 4 months, taking all symptoms together, were all aged more than 75 years. HIT was abnormal in 18% of cases before implantation and in 59% after (P=NS). HST showed nystagmus in one patient both before and after surgery. Only 18% of patients showed nystagmus induced by SVT before surgery, increasing to one-third after surgery (P=NS). Caloric test of the lateral canal showed hypofunction in 50% of cases before surgery, including 10% of cases with areflexia. This rate increased after surgery to 58%, with 18% areflexia (P=NS). cVEMPs were not detected in 68% of cases before implantation and this rate increased to 86% after surgery (P=NS). There were no significant associations (P>0.05) between test results and symptoms. CONCLUSIONS In the medium term, although older subjects more frequently presented vestibular disorder, cochlear implantation induced little vertigo or balance disorder, sometimes even improving vestibular function. However, vestibular disorders were frequent preoperatively and increased postoperatively. We tested vestibular function on different stimulation frequencies and yet found no correlation between postoperative test results and postoperative vertigo.
Collapse
Affiliation(s)
- V Colin
- Service ORL, CHU de Saint-Étienne, 42270 Saint-Priest-en-Jarez, France.
| | - P Bertholon
- Service ORL, CHU de Saint-Étienne, 42270 Saint-Priest-en-Jarez, France
| | - S Roy
- Service ORL, CHU de Saint-Étienne, 42270 Saint-Priest-en-Jarez, France
| | - A Karkas
- Service ORL, CHU de Saint-Étienne, 42270 Saint-Priest-en-Jarez, France
| |
Collapse
|
31
|
Musazzi UM, Franzé S, Cilurzo F. Innovative pharmaceutical approaches for the management of inner ear disorders. Drug Deliv Transl Res 2018; 8:436-449. [PMID: 28462501 DOI: 10.1007/s13346-017-0384-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The sense of hearing is essential for permitting human beings to interact with the environment, and its dysfunctions can strongly impact on the quality of life. In this context, the cochlea plays a fundamental role in the transformation of the airborne sound waves into electrical signals, which can be processed by the brain. However, several diseases and external stimuli (e.g., noise, drugs) can damage the sensorineural structures of cochlea, inducing progressive hearing dysfunctions until deafness. In clinical practice, the current pharmacological approaches to treat cochlear diseases are based on the almost exclusive use of systemic steroids. In the last decades, the efficacy of novel therapeutic molecules has been proven, taking advantage from a better comprehension of the pathological mechanisms underlying many cochlear diseases. In addition, the feasibility of intratympanic administration of drugs also permitted to overcome the pharmacokinetic limitations of the systemic drug administration, opening new frontiers in drug delivery to cochlea. Several innovative drug delivery systems, such as in situ gelling systems or nanocarriers, were designed, and their efficacy has been proven in vitro and in vivo in cochlear models. The current review aims to describe the art of state in the cochlear drug delivery, highlighting lights and shadows and discussing the most critical aspects still pending in the field.
Collapse
Affiliation(s)
- Umberto M Musazzi
- Department of Pharmaceutical Sciences, Università degli Studi di Milano, Via G. Colombo, 71, 20133, Milan, Italy.
| | - Silvia Franzé
- Department of Pharmaceutical Sciences, Università degli Studi di Milano, Via G. Colombo, 71, 20133, Milan, Italy
| | - Francesco Cilurzo
- Department of Pharmaceutical Sciences, Università degli Studi di Milano, Via G. Colombo, 71, 20133, Milan, Italy
| |
Collapse
|
32
|
Skarżyńska MB, Skarżyński PH, Król B, Kozieł M, Osińska K, Gos E, Skarżyński H. Preservation of Hearing Following Cochlear Implantation Using Different Steroid Therapy Regimens: A Prospective Clinical Study. Med Sci Monit 2018; 24:2437-2445. [PMID: 29680860 PMCID: PMC5933206 DOI: 10.12659/msm.906210] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Background A prospective clinical study was conducted to assess different regimens of steroid therapy and preservation of hearing following cochlear implantation. Material/Methods Study participants were ≥18 years-of-age, with a cochlear duct length ≥27.1 mm measured by computed tomography (CT), with hearing sound levels in the range of 10–120 decibels (dB) and sound frequencies of 125–250 hertz (Hz); sound levels of 35–120 dB and frequencies of 500–1,000 Hz; sound levels of 75–120 dB and frequencies of 2,000–8,000 Hz. Study exclusion criteria included diseases with contraindications for steroid therapy or medications that increased the effects of steroids. Patients had cochlear implantation and were divided into three treatment groups: intravenous (IV) steroid therapy (standard steroid therapy): combined oral and IV steroid therapy (prolonged steroid therapy); and a control group (cochlear implantation without steroid therapy). Hearing preservation was established by pure tone audiometry based on the pre-operative and postoperative average hearing thresholds according to the formula developed by the HEARRING Network. Results There were 36 patients included in the study. In all cases, the cochlear implant electrode was inserted via the round window approach with a straight electrode length of 28 mm. Patients with combined oral and IV steroid therapy (prolonged steroid therapy) had better results when compared with patients with intravenous (IV) steroid therapy (standard steroid therapy) and the control group. Conclusions Prolonged steroid therapy using combined oral and IV steroids stabilized hearing thresholds and preserved hearing in adult patients following cochlear implantation.
Collapse
Affiliation(s)
- Magdalena Beata Skarżyńska
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland.,Institute of Sensory Organs, Kajetany, Poland
| | - Piotr Henryk Skarżyński
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland.,World Hearing Center, Kajetany, Poland.,Centre of Hearing and Speech Medincus, Kajetany, Poland.,Heart Failure and Cardiac Rehabilitation Department, Medical University of Warsaw, Warsaw, Poland
| | - Bartłomiej Król
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland.,World Hearing Center, Kajetany, Poland
| | - Magdalena Kozieł
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland.,World Hearing Center, Kajetany, Poland
| | - Kamila Osińska
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland.,World Hearing Center, Kajetany, Poland
| | - Elżbieta Gos
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland.,World Hearing Center, Kajetany, Poland
| | - Henryk Skarżyński
- Institute of Physiology and Pathology of Hearing, Warsaw, Poland.,World Hearing Center, Kajetany, Poland
| |
Collapse
|
33
|
|
34
|
Drouillard M, Torres R, Mamelle E, De Seta D, Sterkers O, Ferrary E, Nguyen Y. Influence of electrode array stiffness and diameter on hearing in cochlear implanted guinea pig. PLoS One 2017; 12:e0183674. [PMID: 28837630 PMCID: PMC5570298 DOI: 10.1371/journal.pone.0183674] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Accepted: 08/08/2017] [Indexed: 11/18/2022] Open
Abstract
During cochlear implantation, electrode array translocation and trauma should be avoided to preserve residual hearing. The aim of our study was to evaluate the effect of physical parameters of the array on residual hearing and cochlear structures during insertion. Three array prototypes with different stiffnesses or external diameters were implanted in normal hearing guinea pigs via a motorized insertion tool carried on a robot-based arm, and insertion forces were recorded. Array prototypes 0.4 and 0.4R had 0.4 mm external diameter and prototype 0.3 had 0.3 mm external diameter. The axial stiffness was set to 1 for the 0.4 prototype and the stiffnesses of the 0.4R and 0.3 prototypes were calculated from this as 6.8 and 0.8 (relative units), respectively. Hearing was assessed preoperatively by the auditory brainstem response (ABR), and then at day 7 and day 30 post-implantation. A study of the macroscopic anatomy was performed on cochleae harvested at day 30 to examine the scala location of the array. At day 7, guinea pigs implanted with the 0.4R array had significantly poorer hearing results than those implanted with the 0.3 array (26±17.7, 44±23.4, 33±20.5 dB, n = 7, vs 5±8.7, 1±11.6, 12±11.5 dB, n = 6, mean±SEM, respectively, at 8, 16 and 24 kHz, p<0.01) or those implanted with the 0.4 array (44±23.4 dB, n = 7, vs 28±21.7 dB, n = 7, at 16 kHz, p<0.05). Hearing remained stable from day 7 to day 30. The maximal peak of insertion force was higher with the 0.4R array than with the 0.3 array (56±23.8 mN, n = 7, vs 26±8.7 mN, n = 6). Observation of the cochleae showed that an incorrectly positioned electrode array or fibrosis were associated with hearing loss ≥40 dB (at 16 kHz). An optimal position in the scala tympani with a flexible and thin array and prevention of fibrosis should be the primary objectives to preserve hearing during cochlear implantation.
Collapse
Affiliation(s)
- Mylène Drouillard
- Sorbonne Universités, Université Pierre et Marie Curie Paris 6, Inserm, Unité “Réhabilitation chirurgicale mini-invasive et robotisée de l'audition”, Paris, France
- AP-HP, GHU Pitié-Salpêtrière, Service ORL, Otologie, implants auditifs et chirurgie de la base du crâne, Paris, France
| | - Renato Torres
- Sorbonne Universités, Université Pierre et Marie Curie Paris 6, Inserm, Unité “Réhabilitation chirurgicale mini-invasive et robotisée de l'audition”, Paris, France
- AP-HP, GHU Pitié-Salpêtrière, Service ORL, Otologie, implants auditifs et chirurgie de la base du crâne, Paris, France
| | - Elisabeth Mamelle
- Sorbonne Universités, Université Pierre et Marie Curie Paris 6, Inserm, Unité “Réhabilitation chirurgicale mini-invasive et robotisée de l'audition”, Paris, France
- AP-HP, GHU Pitié-Salpêtrière, Service ORL, Otologie, implants auditifs et chirurgie de la base du crâne, Paris, France
| | - Daniele De Seta
- Sorbonne Universités, Université Pierre et Marie Curie Paris 6, Inserm, Unité “Réhabilitation chirurgicale mini-invasive et robotisée de l'audition”, Paris, France
- AP-HP, GHU Pitié-Salpêtrière, Service ORL, Otologie, implants auditifs et chirurgie de la base du crâne, Paris, France
| | - Olivier Sterkers
- Sorbonne Universités, Université Pierre et Marie Curie Paris 6, Inserm, Unité “Réhabilitation chirurgicale mini-invasive et robotisée de l'audition”, Paris, France
- AP-HP, GHU Pitié-Salpêtrière, Service ORL, Otologie, implants auditifs et chirurgie de la base du crâne, Paris, France
| | - Evelyne Ferrary
- Sorbonne Universités, Université Pierre et Marie Curie Paris 6, Inserm, Unité “Réhabilitation chirurgicale mini-invasive et robotisée de l'audition”, Paris, France
- AP-HP, GHU Pitié-Salpêtrière, Service ORL, Otologie, implants auditifs et chirurgie de la base du crâne, Paris, France
| | - Yann Nguyen
- Sorbonne Universités, Université Pierre et Marie Curie Paris 6, Inserm, Unité “Réhabilitation chirurgicale mini-invasive et robotisée de l'audition”, Paris, France
- AP-HP, GHU Pitié-Salpêtrière, Service ORL, Otologie, implants auditifs et chirurgie de la base du crâne, Paris, France
- * E-mail:
| |
Collapse
|
35
|
Greaver L, Eskridge H, Teagle HFB. Considerations for Pediatric Cochlear Implant Recipients With Unilateral or Asymmetric Hearing Loss: Assessment, Device Fitting, and Habilitation. Am J Audiol 2017; 26:91-98. [PMID: 28291986 DOI: 10.1044/2016_aja-16-0051] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2016] [Accepted: 09/16/2016] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The purpose of this clinical report is to present case studies of children who are nontraditional candidates for cochlear implantation because they have significant residual hearing in 1 ear and to describe outcomes and considerations for their audiological management and habilitation. METHOD Case information is presented for 5 children with profound hearing loss in 1 ear and normal or mild-to-moderate hearing loss in the opposite ear and who have undergone unilateral cochlear implantation. Pre- and postoperative assessments were performed per typical clinic routines with modifications described. Postimplant habilitation was customized for each recipient using a combination of traditional methods, newer technologies, and commercial materials. RESULTS The 5 children included in this report are consistent users of their cochlear implants and demonstrate speech recognition in the implanted ear when isolated from the better hearing ear. CONCLUSIONS Candidacy criteria for cochlear implantation are evolving. Children with single-sided deafness or asymmetric hearing loss who have traditionally not been considered candidates for cochlear implantation should be evaluated on a case-by-case basis. Audiological management of these recipients is not vastly different compared with children who are traditional cochlear implant recipients. Assessment and habilitation techniques must be modified to isolate the implanted ear to obtain accurate results and to provide meaningful therapeutic intervention.
Collapse
|
36
|
A synthetic AAV vector enables safe and efficient gene transfer to the mammalian inner ear. Nat Biotechnol 2017; 35:280-284. [PMID: 28165475 PMCID: PMC5340646 DOI: 10.1038/nbt.3781] [Citation(s) in RCA: 220] [Impact Index Per Article: 31.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2016] [Accepted: 01/04/2017] [Indexed: 01/01/2023]
Abstract
Efforts to develop gene therapies for hearing loss have been hampered by the lack of safe, efficient, and clinically relevant delivery modalities1, 2. Here we demonstrate the safety and efficiency of Anc80L65, a rationally designed synthetic vector3, for transgene delivery to the mouse cochlea. Cochlear explants incubated with Anc80L65 encoding eGFP demonstrated high level transduction of inner and outer hair cells (60–100%). Injection of Anc80L65 through the round window membrane resulted in highly efficient transduction of inner and outer hair cells, a substantial improvement over conventional adeno-associated virus (AAV) vectors. Anc80L65 round window injection was well tolerated, as indicated by sensory cell function, hearing and vestibular function, and immunologic parameters. The ability of Anc80L65 to target outer hair cells at high rates, a requirement for restoration of complex auditory function, may enable future gene therapies for hearing and balance disorders.
Collapse
|
37
|
Brant JA, Ruckenstein MJ. Electrode selection for hearing preservation in cochlear implantation: A review of the evidence. World J Otorhinolaryngol Head Neck Surg 2016; 2:157-160. [PMID: 29204561 PMCID: PMC5698544 DOI: 10.1016/j.wjorl.2016.08.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2016] [Accepted: 08/10/2016] [Indexed: 11/30/2022] Open
Abstract
Objective To review and assess the ideal length of electrode in cochlear implant patients for hearing preservation. Methods The English language literature was reviewed for studies including hearing preservation and speech understanding for electrodes of different lengths. Results One prospective trial was found, and there were no studies that randomized patients into different length electrodes with an intent to preserve hearing. Eight studies total included multiple length electrodes and contained data regarding hearing preservation. Conclusions Although there is some evidence that indicates that shorter electrodes may improve both short and long-term hearing preservation rates in cochlear implant patients, no study has directly compared implant length on hearing preservation in a similar patient population. A randomized trial of short and standard length electrodes for hearing preservation is warranted. In the interim, utilization of current electrodes measuring 20-25 mm could seem to be a prudent approach when seeking to preserve residual hearing without unduly compromising cochlear coverage.
Collapse
Affiliation(s)
- Jason A Brant
- Department of Otorhinolaryngology-Head and Neck Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Michael J Ruckenstein
- Department of Otorhinolaryngology-Head and Neck Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| |
Collapse
|
38
|
Postinsertional Cable Movements of Cochlear Implant Electrodes and Their Effects on Intracochlear Pressure. BIOMED RESEARCH INTERNATIONAL 2016; 2016:3937196. [PMID: 27900329 PMCID: PMC5120182 DOI: 10.1155/2016/3937196] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2016] [Accepted: 10/17/2016] [Indexed: 11/23/2022]
Abstract
Introduction. To achieve a functional atraumatic cochlear implantation, intracochlear pressure changes during the procedure should be minimized. Postinsertional cable movements are assumed to induce intracochlear pressure changes. The aim of this study was to observe intracochlear pressure changes due to postinsertional cable movements. Materials and Methods. Intracochlear pressure changes were recorded in a cochlear model with a micro-pressure sensor positioned in the apical region of the cochlea model to follow the maximum amplitude and pressure gain velocity in intracochlear pressure. A temporal bone mastoid cavity was attached to the model to simulate cable positioning. The compared conditions were (1) touching the unsealed electrode, (2) touching the sealed electrode, (3) cable storage with an unfixed cable, and (4) cable storage with a fixed cable. Results. We found statistically significant differences in the occurrence of maximum amplitude and pressure gain velocity in intracochlear pressure changes under the compared conditions. Comparing the cable storage conditions, a cable fixed mode offers significantly lower maximum pressure amplitude and pressure gain velocity than the nonfixed mode. Conclusion. Postinsertional cable movement led to a significant pressure transfer into the cochlea. Before positioning the electrode cable in the mastoid cavity, fixation of the cable is recommended.
Collapse
|