Valič M, Milošev I, Levašič V, Blas M, Podovšovnik E, Koren J, Trebše R. Linear and Volumetric Polyethylene Wear Patterns after Primary Cruciate-Retaining Total Knee Arthroplasty Failure: An Analysis Using Optical Scanning and Computer-Aided Design Models. MATERIALS (BASEL, SWITZERLAND) 2024; 17:5007. [PMID: 39459713 PMCID: PMC11509131 DOI: 10.3390/ma17205007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2024] [Revised: 10/04/2024] [Accepted: 10/11/2024] [Indexed: 10/28/2024]
Abstract
(1) Background: Analyses of retrieved inserts allow for a better understanding of TKA failure mechanisms and the detection of factors that cause increased wear. The purpose of this implant retrieval study was to identify whether insert volumetric wear significantly differs among groups of common causes of total knee arthroplasty failure, whether there is a characteristic wear distribution pattern for a common cause of failure, and whether nominal insert size and component size ratio (femur-to-insert) influence linear and volumetric wear rates. (2) Methods: We digitally reconstructed 59 retrieved single-model cruciate-retaining inserts and computed their articular load-bearing surface wear utilizing an optical scanner and computer-aided design models as references. After comprehensively reviewing all cases, each was categorized into one or more of the following groups: prosthetic joint infection, osteolysis, clinical loosening of the component, joint malalignment or component malposition, instability, and other isolated causes. The associations between volumetric wear and causes of failure were estimated using a multiple linear regression model adjusted for time in situ. Insert linear penetration wear maps from the respective groups of failure were further processed and merged to create a single average binary image, highlighting a potential wear distribution pattern. The differences in wear rates according to nominal insert size (small vs. medium vs. large) and component size ratio (≤1 vs. >1) were tested using the Kruskal-Wallis test and the Mann-Whitney test, respectively. (3) Results: Patients with identified osteolysis alone and those also with clinical loosening of the component had significantly higher volumetric wear when compared to those without both causes (p = 0.016 and p = 0.009, respectively). All other causes were not significantly associated with volumetric wear. The instability group differentiated from the others with a combined peripheral antero-posterior wear distribution. Linear and volumetric wear rates showed no significant differences when compared by nominal insert size (small vs. medium vs. large, p = 0.563 and p = 0.747, respectively) or by component (femoral-to-insert) size ratio (≤1 vs. >1, p = 0.885 and p = 0.055, respectively). (4) Conclusions: The study found increased volumetric wear in cases of osteolysis alone, with greater wear when combined with clinical loosening compared to other groups. The instability group demonstrated a characteristic peripheral anterior and posterior wear pattern. Insert size and component size ratio seem not to influence wear rates.
Collapse
Affiliation(s)
- Matej Valič
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
- Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| | - Ingrid Milošev
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
- Jožef Stefan Institute, Jamova cesta 39, 1000 Ljubljana, Slovenia
| | - Vesna Levašič
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
| | - Mateja Blas
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
| | - Eva Podovšovnik
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
- Faculty of Tourism Studies-Turistica, University of Primorska, Obala 11a, 6320 Portorož, Slovenia
| | - Jaka Koren
- Faculty of Electrical Engineering, University of Ljubljana, Tržaška cesta 25, 1000 Ljubljana, Slovenia;
| | - Rihard Trebše
- Valdoltra Orthopaedic Hospital, Jadranska cesta 31, 6280 Ankaran, Slovenia; (I.M.); (V.L.); (M.B.); (E.P.); (R.T.)
- Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| |
Collapse
|
2
|
Dreyer MJ, Weisse B, Contreras Raggio JI, Zboray R, Taylor WR, Preiss S, Horn N. The influence of implant design and limb alignment on in vivo wear rates of fixed-bearing and rotating-platform knee implant retrievals. J Orthop Res 2024; 42:777-787. [PMID: 37975250 DOI: 10.1002/jor.25734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 10/11/2023] [Accepted: 11/14/2023] [Indexed: 11/19/2023]
Abstract
Analysis of polyethylene (PE) wear in knee implants is crucial for understanding the factors leading to revision in total knee arthroplasty. Importantly, current experimental and computational methods for predicting insert wear can only be validated against true in vivo measurements from retrievals. This study quantitatively investigated in vivo PE wear rates in fixed-bearing (FB) (n = 21) and rotating-platform (n = 53) implant retrievals. 3D surface geometry of the retrievals was measured using a structured light scanner. Then, a reference surface that included the deformation, but not the wear that the retrievals had experienced in vivo, was constructed using a fully automatic surface reconstruction algorithm. Finally, wear volume was calculated from the deviation between the worn and reconstructed surfaces. The measurement and analysis techniques were validated and the algorithm was found to produce errors of only 0.2% relative to the component volumes. In addition to quantifying cohort-level wear rates, the effect of mechanical axis limb alignment on mediolateral wear distribution was examined for a subset of the retrievals (n = 14 + 26). Our results show that FB implants produce significantly (p = 0.04) higher topside wear rates (24.6 ± 10.1 mm3/year) than rotating-platform implants (15.3 ± 8.0 mm3/year). This effect was larger than that of limb alignment, which had a smaller and nonsignificant influence on overall wear rates (+4.5 ± 11.6 mm3/year, p = 0.43). However, increased varus alignment was associated significantly with greater medial compartment wear in both the FB and rotating-platform designs (+1.7 ± 1.3%/° and +1.8 ± 1.6%/°). Our findings emphasize the importance of implant design and limb alignment on wear outcomes, providing reference data for improving implant performance and longevity.
Collapse
Affiliation(s)
- Michael J Dreyer
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
- Laboratory for Mechanical Systems Engineering, Empa, Dübendorf, Switzerland
| | - Bernhard Weisse
- Laboratory for Mechanical Systems Engineering, Empa, Dübendorf, Switzerland
| | - José Ignacio Contreras Raggio
- Laboratory for Mechanical Systems Engineering, Empa, Dübendorf, Switzerland
- Facultad de Ingeniería y Ciencias, Universidad Adolfo Ibáñez, Viña del Mar, Chile
| | - Robert Zboray
- Center for X-ray Analytics, Empa, Dübendorf, Switzerland
| | - William R Taylor
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland
| | - Stefan Preiss
- Department of Lower Extremities, Schulthess Clinic, Zürich, Switzerland
| | - Nils Horn
- Department of Lower Extremities, Schulthess Clinic, Zürich, Switzerland
| |
Collapse
|
3
|
Dreyer MJ, Kneifel P, Hosseini Nasab SH, Weisse B, Taylor WR. A novel method to accurately recreate in vivo loads and kinematics in computational models of the knee. Comput Methods Biomech Biomed Engin 2023:1-7. [PMID: 37128680 DOI: 10.1080/10255842.2023.2206934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Despite availability of in vivo knee loads and kinematics data, conventional load- and displacement-controlled configurations still can't accurately predict tibiofemoral loads from kinematics or vice versa. We propose a combined load- and displacement-control method for joint-level simulations of the knee to reliably reproduce in vivo contact mechanics. Prediction errors of the new approach were compared to those of conventional purely load- or displacement-controlled models using in vivo implant loads and kinematics for multiple subjects and activities (CAMS-Knee dataset). Our method reproduced both loads and kinematics more closely than conventional models and thus demonstrates clear advantages for investigating tibiofemoral contact or wear.
Collapse
Affiliation(s)
- Michael J Dreyer
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zurich, Switzerland
- Laboratory for Mechanical Systems Engineering, Empa, Dübendorf, Switzerland
| | - Paul Kneifel
- Berlin Institute of Health at Charité-Universitätsmedizin Berlin, Julius Wolff Institute, Berlin, Germany
| | | | - Bernhard Weisse
- Laboratory for Mechanical Systems Engineering, Empa, Dübendorf, Switzerland
| | - William R Taylor
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zurich, Switzerland
| |
Collapse
|
4
|
Cowie RM, Jennings LM. Third body damage and wear in arthroplasty bearing materials: A review of laboratory methods. BIOMATERIALS AND BIOSYSTEMS 2021; 4:100028. [PMID: 36824573 PMCID: PMC9934499 DOI: 10.1016/j.bbiosy.2021.100028] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 08/16/2021] [Accepted: 09/05/2021] [Indexed: 12/28/2022] Open
Abstract
Third body wear of arthroplasty bearing materials can occur when hard particles such as bone, bone cement or metal particles become trapped between the articulating surfaces. This can accelerate overall implant wear, potentially leading to early failure. With the development of novel bearing materials and coatings, there is a need to develop and standardise test methods which reflect third body damage seen on retrieved implants. Many different protocols and approaches have been developed to replicate third body wear in the laboratory but there is currently no consensus as to the optimal method for simulating this wear mode, hence the need to better understand existing methods. The aim of this study was to review published methods for experimental simulation of third body wear of arthroplasty bearing materials, to discuss the advantages and limitations of different approaches, the variables to be considered when designing a method and to highlight gaps in the current literature. The methods were divided into those which introduced abrasive particles into the articulating surfaces of the joint and those whereby third body damage is created directly to the articulating surfaces. However, it was found that there are a number of parameters, for example the influence of particle size on wear, which are not yet fully understood. The study concluded that the chosen method or combination of methods used should primarily be informed by the research question to be answered and risk analysis of the device.
Collapse
Affiliation(s)
- Raelene M Cowie
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK
| | - Louise M Jennings
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds LS2 9JT, UK
| |
Collapse
|
5
|
Askari E, Andersen MS. Effect of Ligament Properties on Nonlinear Dynamics and Wear Prediction of Knee Prostheses. J Biomech Eng 2021; 143:021014. [PMID: 33030212 DOI: 10.1115/1.4048707] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Indexed: 11/08/2022]
Abstract
Although wear is known as the primary cause of long-time failure of total knee arthroplasty (TKA), it can be vital in short- and midterm TKA failure due to laxity. One of the reasons leading to joint laxity and instability is ligamentous insufficiency. This study, therefore, aims to investigate the effects of insufficient ligaments-related knee laxity on both nonlinear dynamics and wear of TKA. The study hypothesizes (a) ligamentous insufficiency can increase TKA damage; (b) stiffness reduction of each of the posterior cruciate ligament (PCL) and medial-lateral collateral ligaments (MCL-LCL) can differently contribute to TKA damage. A forward dynamics methodology is developed and the ligament behavior is simulated employing an asymmetric nonlinear elastic model. External loads and moment, due to the presence of all soft tissues, e.g., muscles and hip joint reaction forces, applied to the femoral bone are determined using a musculoskeletal approach linked to the developed model. A mesh density analysis is performed and comparing outcomes with that available in the literature allows for the assessment of our approach. From the results acquired, reduced PCL stiffness leads to an increase in linear wear rates and results in the maximum damage in TKAs. However, the maximum linear wear rates on both condyles occur once the stiffness of all ligaments is reduced. Moreover, the worn area of the tibia surface increases with the reduction in MCL-LCL stiffness on the medial condyle. The joint with insufficient PCL also shows a considerable increase in ligament forces right after toe-off.
Collapse
Affiliation(s)
- Ehsan Askari
- Department of Electromechanical, Systems and Metal Engineering, Ghent University, Zwijnaarde B-9052, Belgium
| | - Michael S Andersen
- Department of Materials and Production, Aalborg University, Aalborg 9220, Denmark
| |
Collapse
|
6
|
Newton MD, Junginger L, Maerz T. Automated MicroCT-based bone and articular cartilage analysis using iterative shape averaging and atlas-based registration. Bone 2020; 137:115417. [PMID: 32416288 DOI: 10.1016/j.bone.2020.115417] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Revised: 05/02/2020] [Accepted: 05/12/2020] [Indexed: 01/09/2023]
Abstract
Micro-computed tomography (μCT) and contrast-enhanced μCT are important tools for preclinical analysis of bone and articular cartilage (AC). Quantitative data from these modalities is highly dependent on the accuracy of tissue segmentations, which are often obtained via time-consuming manual contouring and are prone to inter- and intra-observer variability. Automated segmentation strategies could mitigate these issues, but few such approaches have been described in the context of μCT. Here, we validated a fully-automated strategy for bone and AC segmentation based on registration of an average tissue atlas. Femora from healthy and arthritic rats underwent μCT scanning, and epiphyseal trabecular bone and AC volumes were manually contoured by an expert. Average tissue atlases composed of 1, 3, 5, 10 and 20 pre-contoured training images (n = 10 atlases/group) were generated using iterative shape averaging and registered onto unknown images via affine and non-rigid registration. Atlas-based and expert-defined volumes for bone and AC were compared in terms of shape-based similarity metrics, as well as morphometric and densitometric parameters. Our results demonstrate that atlas-based registrations were capable of highly accurate and consistent segmentation. Atlases built from as few as 3 training images had no incidence of mal-registration and exhibited improved incidence of accurate registration, and higher sensitivity and specificity compared to atlases built from only one training image. Atlas-based segmentation of bone and AC from μCT images is a robust and accurate alternative to manual tissue segmentation, enabling faster, more consistent segmentation of pre-clinical datasets.
Collapse
Affiliation(s)
- Michael D Newton
- Orthopaedic Research Laboratories, Beaumont Health, Royal Oak, MI, United States of America
| | - Lucas Junginger
- Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI, United States of America
| | - Tristan Maerz
- Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI, United States of America.
| |
Collapse
|
7
|
Ngai V, Kunze J, Cip J, Laurent MP, Jacobs JJ, Wimmer MA. Backside wear of tibial polyethylene components is affected by gait pattern: A knee simulator study using rare earth tracer technology. J Orthop Res 2020; 38:1607-1616. [PMID: 32410286 PMCID: PMC7329356 DOI: 10.1002/jor.24720] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Revised: 04/10/2020] [Accepted: 05/01/2020] [Indexed: 02/04/2023]
Abstract
The aim of this study was to determine the effect of two in-vivo-determined gait patterns, one with low and one with high anteroposterior (AP) motion, on total and backside polyethylene insert wear in comparison with the ISO (International Organization for Standardization) standard 14243-3. In order to differentiate and accurately quantify topside and backside wear, a novel technique was employed where different lanthanide tracers were incorporated into the polyethylene during manufacture. Wear particle analysis was conducted following established protocols. For all tested liners and motion protocols, the chemically calculated wear rates correlated closely with gravimetrically determined wear. Both in vivo motion groups displayed higher wear rates than the ISO group following the order of the AP motion amplitudes. Backside wear for ISO constituted 2.76% ± 0.90% (mean ± SE) of the total wear, increasing significantly to 15.8% ± 3.2% for the low AP and further increasing to 19.3% ± 0.95% for the high AP motion protocol. The mean wear particle sizes were under 200 nm for all three motion patterns, being largest for the protocol with high AP motion. Particle release from the low and high AP gait patterns was 1.9 to 2.8 times that from the ISO protocol. Testing for the proportion of backside wear across various activities of daily living should be an important consideration in evaluating knee prostheses wear.
Collapse
Affiliation(s)
| | - Joachim Kunze
- Rush University Medical Center, Chicago, IL,Hamburg University of Technology, Germany
| | | | | | | | | |
Collapse
|
8
|
Abstract
BACKGROUND Revision of TKA as a result of polyethylene wear is decreasing, but long-term wear performance of polyethylene is still a topic of interest to surgeons and device manufacturers seeking to improve longevity. Measuring wear of modern, wear-resistant implants has been described using radiostereometric analysis (RSA). Performing in vivo measurements would establish whether implant retrieval studies are representative of wear in well-performing knees. QUESTIONS/PURPOSES For a single knee implant system, we sought to determine (1) the linear wear rate using RSA; (2) the association between demographic factors and wear rate; and (3) the association between limb alignment and wear rate. METHODS A total of 49 patients with a minimum followup of 10 years (median, 12 years; range, 10-20 years) were retrospectively selected. During the examined period, 4082 TKAs were performed of which 2085 were the implant examined in this study. There were 71 of these patients who met the criteria including an available full-leg radiograph postoperatively, and 34 of these patients returned for examination along with 15 additional from a separate RSA study that also met the criteria. All patients received a posterior-stabilized, cobalt-chromium-on-conventional polyethylene total knee implant from a single implant system, which was the most commonly used at our institution at the time. Patients underwent standing RSA examinations from 0° to 120° of flexion at a single time point without the use of marker beads. Linear wear rates (including creep) were measured based on intersections between the femoral component and tibial insert models. Associations between wear and patient age at surgery, sex, height, weight, body mass index, tibial insert size, and limb alignment were examined. RESULTS Using the maximum linear wear rate from any flexion angle, the lateral rate was 0.047 mm/year (interquartile range [IQR], 0.034-0.066 mm/year) and the medial rate was 0.052 mm/year (IQR, 0.040-0.069 mm/year). Using the median of the linear wear rates across all flexion angles, the lateral rate was 0.027 mm/year (IQR, 0.017-0.046 mm/year) and the medial rate was 0.038 mm/year (IQR, 0.022-0.054 mm/year). This rate for males was 0.049 mm/year medially (IQR, 0.042-0.077 mm/year) and 0.032 mm/year laterally (IQR, 0.026-0.059 mm/year), and for females was 0.027 mm/year medially (0.016-0.039 mm/year) and 0.020 mm/year laterally (IQR, 0.013-0.032 mm/year). The wear rate for males was greater medially (difference = 0.022 mm/year, p < 0.001) and laterally (difference = 0.012 mm/year, p = 0.008). There were associations between greater wear and increasing height (ρ = 0.48, p < 0.001 medially and ρ = 0.30, p = 0.04 laterally), decreasing body mass index (ρ = -0.31, p = 0.03 medially), and greater implant size (ρ = 0.34, p = 0.02 medially). Increasingly varus leg alignment was associated with greater medial wear (ρ = 0.33, p = 0.02). CONCLUSIONS Greater wear rates were associated with demographic factors and leg alignment. Further RSA wear studies of other modern implant systems would provide complementary information to retrieval studies and valuable data on wear resistance. CLINICAL RELEVANCE Good wear resistance was demonstrated by well-performing implants in patients at long-term followup with wear magnitudes in agreement with reported values from retrieval studies.
Collapse
|
9
|
Kocsis G, Payne CJ, Wallace A, McNally D. Wear analysis of explanted conventional metal back polyethylene glenoid liners. Med Eng Phys 2018; 59:1-7. [PMID: 30082204 DOI: 10.1016/j.medengphy.2018.03.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Revised: 03/11/2018] [Accepted: 03/25/2018] [Indexed: 02/06/2023]
Abstract
INTRODUCTION Glenoid component wear and loosening is the Achilles heel of total shoulder replacement. Analysis of failed, revised implants might give an insight into the causes of component failure. Volumetric assessment of conventional total shoulder replacement glenoid liner wear rate and scanning electron microscopy was accomplished in this study for the purpose. Coherence scanning interferometry (white light scanner) 3D images were acquired. This method requires no physical contact, ionising radiation or extensive surface preparation. METHODS Twenty-four Nottingham total shoulder replacement system metal - back glenoid liners were explanted from revision shoulder arthroplasty cases. A Phase Vision Quartz DBE 800 scanner was used to scan the explanted polyethylene liners. The images of worn liners were registered to the reference image. Differences in wear and wear rate were quantified and central and non-central wear groups were distinguished. The Central wear group had a polyethylene wear rate of 115 ± 55mm3/year (mean ± SD). The non-central group showed a wear rate of 112 ± 42 mm3/year (mean ± SD), which was not significantly different from the central wear group (p = 0.426) Polyethylene liners showing edge wear from unstable shoulder replacements showed a wear rate of 545 mm3/year. Scanning electron microscopy images showed that the polyethylene was wearing in laminar flakes which indicated fatigue wear. CONCLUSION The volumetric wear rate was found to be more than twice as fast as in the case of total hip replacement with the acetabular liner made of the same type of polyethylene. Use of coherence scanning interferometry is proposed for wear analysis.
Collapse
Affiliation(s)
- Gyorgy Kocsis
- University of Nottingham, Nottingham, NG7 2RD, United Kingdom.
| | - Charlie J Payne
- University of Nottingham, Nottingham, NG7 2RD, United Kingdom.
| | - Angus Wallace
- University of Nottingham, Nottingham, NG7 2RD, United Kingdom.
| | - Donal McNally
- University of Nottingham, Nottingham, NG7 2RD, United Kingdom.
| |
Collapse
|
10
|
Zhang J, Chen Z, Wang L, Li D, Jin Z. Load application for the contact mechanics analysis and wear prediction of total knee replacement. Proc Inst Mech Eng H 2017; 231:444-454. [PMID: 28427318 DOI: 10.1177/0954411917693880] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Tibiofemoral contact forces in total knee replacement have been measured at the medial and lateral sites respectively using an instrumented prosthesis, and predicted from musculoskeletal multibody dynamics models with a reasonable accuracy. However, it is uncommon that the medial and lateral forces are applied separately to replace a total axial load according to the ISO standard in the majority of current finite element analyses. In this study, we quantified the different effects of applying the medial and lateral loads separately versus the traditional total axial load application on contact mechanics and wear prediction of a patient-specific knee prosthesis. The load application position played an important role under the medial-lateral load application. The loading set which produced the closest load distribution to the multibody dynamics model was used to predict the contact mechanics and wear for the prosthesis and compared with the total axial load application. The medial-lateral load distribution using the present method was found to be closer to the multibody dynamics prediction than the traditional total axial load application, and the maximum contact pressure and contact area were consistent with the corresponding load variation. The predicted total volumetric wear rate and area were similar between the two load applications. However, the split of the predicted wear volumes on the medial and the lateral sides was different. The lateral volumetric wear rate was 31.46% smaller than the medial from the traditional load application prediction, while from the medial-lateral load application, the lateral side was only 11.8% smaller than the medial. The medial-lateral load application could provide a new and more accurate method of load application for patient-specific preclinical contact mechanics and wear prediction of knee implants.
Collapse
Affiliation(s)
- Jing Zhang
- 1 State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Zhenxian Chen
- 1 State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Ling Wang
- 1 State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Dichen Li
- 1 State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Zhongmin Jin
- 1 State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China.,2 Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK.,3 Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
| |
Collapse
|
11
|
Łapaj Ł, Mróz A, Kokoszka P, Markuszewski J, Wendland J, Helak-Łapaj C, Kruczyński J. Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty. Acta Orthop 2017; 88:62-69. [PMID: 27781667 PMCID: PMC5251266 DOI: 10.1080/17453674.2016.1248202] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2016] [Accepted: 07/31/2016] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Severe backside wear, observed in older generations of total knee replacements (TKRs), led to redesign of locking mechanisms to reduce micromotions between tibial tray and inlay. Since little is known about whether this effectively reduces backside wear in modern designs, we examined backside damage in retrievals of various contemporary fixed-bearing TKRs. Patients and methods - A consecutive series of 102 inlays with a peripheral (Stryker Triathlon, Stryker Scorpio, DePuy PFC Sigma, Aesculap Search Evolution) or dovetail locking mechanism (Zimmer NexGen, Smith and Nephew Genesis II) was examined. Articular and backside surface damage was evaluated using the semiquantitative Hood scale. Inlays were examined using scanning electron microscopy (SEM) to determine backside wear mechanisms. Results - Mean Hood scores for articular (A) and backside (B) surfaces were similar in most implants-Triathlon (A: 46, B: 22), Genesis II (A: 55, B: 24), Scorpio (A: 57, B: 24), PFC (A: 52, B: 20); Search (A: 56, B: 24)-except the NexGen knee (A: 57, B: 60), which had statistically significantly higher backside wear scores. SEM studies showed backside damage caused by abrasion related to micromotion in designs with dovetail locking mechanisms, especially in the unpolished NexGen trays. In implants with peripheral liner locking mechanism, there were no signs of micromotion or abrasion. Instead, "tray transfer" of polyethylene and flattening of machining was observed. Interpretation - Although this retrieval study may not represent well-functioning TKRs, we found that a smooth surface finish and a peripheral locking mechanism reduce backside wear in vivo, but further studies are required to determine whether this actually leads to reduced osteolysis and lower failure rates.
Collapse
Affiliation(s)
- Łukasz Łapaj
- Department of General Orthopaedics, Musculoskeletal Oncology and Trauma Surgery, Poznań University of Medical Sciences
| | | | - Paweł Kokoszka
- Department of General Orthopaedics, Musculoskeletal Oncology and Trauma Surgery, Poznań University of Medical Sciences
| | - Jacek Markuszewski
- Department of General Orthopaedics, Musculoskeletal Oncology and Trauma Surgery, Poznań University of Medical Sciences
| | - Justyna Wendland
- Department of General Orthopaedics, Musculoskeletal Oncology and Trauma Surgery, Poznań University of Medical Sciences
| | - Celina Helak-Łapaj
- Department of Bioinformatics and Computational Biology, Poznań University of Medical Sciences
- Clinical Eye Unit and Pediatric Ophtalmology Service, Heliodor Swiecicki University Hospital, Poznań University of Medical Sciences, Poznań, Poland
| | - Jacek Kruczyński
- Department of General Orthopaedics, Musculoskeletal Oncology and Trauma Surgery, Poznań University of Medical Sciences
| |
Collapse
|
12
|
How Does Wear Rate Compare in Well-functioning Total Hip and Knee Replacements? A Postmortem Polyethylene Liner Study. Clin Orthop Relat Res 2016; 474:1867-75. [PMID: 26891896 PMCID: PMC4925408 DOI: 10.1007/s11999-016-4749-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2015] [Accepted: 02/10/2016] [Indexed: 01/31/2023]
Abstract
BACKGROUND The longevity of total hip (THR) and knee replacements (TKR) that used historical bearing materials of gamma-in-air sterilized UHMWPE was affected more by osteolysis in THRs than in TKRs, although osteolysis remains a concern in TKRs. Therefore, the study of polyethylene wear is still of interest for the knee, particularly because few studies have investigated volumetric material loss in tibial knee inserts. For this study, a unique collection of autopsy-retrieved TKR and THR components that were well-functioning at the time of retrieval was used to compare volumetric wear differences between hip and knee polyethylene components made from identical material. QUESTIONS/PURPOSES The following questions were addressed: (1) How much did the hip liners wear and what wear patterns did they exhibit? (2) How much did the knee inserts wear and what wear patterns did they exhibit? (3) What is the ratio between TKR and THR wear after controlling for implantation time and patient age? METHODS We compared 23 THR components (Harris-Galante [HG] and HG II) and 20 TKR components (Miller-Galante [MG II]) that were retrieved postmortem. The components were made from the same polyethylene formulation and with similar manufacturing and sterilization (gamma-in-air) processes. Twenty-one patients (12 males, nine females) had THRs and 16 (four males, 12 females) had TKRs. Patients who had TKRs had an older (p = 0.001) average age than patients who had THRs (age, 75 years; SD, 10, versus 66 years; SD, 12, respectively). Only well-functioning components were included in this study. Therefore, implants retrieved postmortem from physically active patients and implanted for at least 2 years were considered. In addition, only normally wearing TKR components were considered, ie, those with fatigue wear (delamination) were excluded. The wear volume of each component was measured using metrology. For the tibial inserts an autonomous mathematic reconstruction method was used for quantification. RESULTS The acetabular liners of the THR group had a wear rate of 38 mm(3) per year (95% CI, 29-47 mm(3)/year). Excluding patients with low-activity, the wear rate was 47 mm(3) per year (95% CI, 37-56 mm(3)/year). The wear rate of normally wearing tibial inserts was 17 mm(3) per year (95% CI, -6 to 40 mm(3)/year). After controlling for the relevant confounding variable of age, we found a TKR/THR wear rate ratio of 0.5 (95% CI, 0.29-0.77) at 70 years of age with a slightly increasing difference with increasing age. CONCLUSIONS Excluding delamination, TKRs exhibited lower articular wear rates than THRs for historical polyethylene in these two unique cohorts of postmortem retrievals. CLINICAL RELEVANCE The lower TKR wear rate is in line with the lower incidence of osteolysis in TKRs compared with THRs.
Collapse
|
13
|
Knowlton CB, Bhutani P, Wimmer MA. Relationship of surface damage appearance and volumetric wear in retrieved TKR polyethylene liners. J Biomed Mater Res B Appl Biomater 2016; 105:2053-2059. [PMID: 27401236 DOI: 10.1002/jbm.b.33684] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Revised: 01/27/2016] [Accepted: 03/29/2016] [Indexed: 11/08/2022]
Abstract
Recently developed techniques have enabled volume loss measurements on surgically retrieved total knee replacements (TKR). However, it is not well understood how volume loss relates to polyethylene surface damage appearance. Sixty-four fixed bearing cruciate retaining components retrieved from revision and postmortem surgeries were analyzed for penetration and volume loss on the topside articular surface. An autonomous reconstruction method was used to approximate the original unworn surfaces. Surface damage patterns were also mapped using a video microscope, and each pattern's contribution to volume loss was calculated. With consideration for creep, a total wear rate of 12.9 ± 5.97 mm3 /year was found for the population. The penetration rate was 0.035 ± 0.017 mm/year medially and 0.034 ± 0.011 mm/year laterally, of which the location on the plateau varied greatly. Although striated patterns contributed to most to volume loss, damage patterns generally were only moderate predictors of material volume loss. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2053-2059, 2017.
Collapse
Affiliation(s)
- Christopher B Knowlton
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois.,Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois
| | - Priyanka Bhutani
- Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois
| | - Markus A Wimmer
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, Illinois.,Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois
| |
Collapse
|