1
|
Vorimore C, Verhaegen JCF, Innmann M, Monk AP, Ling C, Grammatopoulos G. Change in cup orientation from supine to standing posture: a prospective cohort study of 419 total hip arthroplasties. Acta Orthop 2024; 95:425-432. [PMID: 39037005 PMCID: PMC11261814 DOI: 10.2340/17453674.2024.41091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Accepted: 06/23/2024] [Indexed: 07/23/2024] Open
Abstract
BACKGROUND AND PURPOSE Arthroplasty surgeons traditionally assess cup orientation after total hip arthroplasty (THA) on supine radiographs. Contemporary hip-spine analyses provide information on standing, functional cup orientation. This study aims to (i) characterize cup orientations when supine and standing; (ii) determine orientation differences between postures; and (iii) identify factors associated with magnitude of orientation differences. METHODS This is a 2-center, multi-surgeon, prospective, consecutive cohort study. 419 primary THAs were included (57% women; mean age: 64 years, standard deviation [SD] 11). All patients underwent supine and standing antero-posterior pelvic and lateral spinopelvic radiographs. Cup orientation and spinopelvic parameters were measured. Target cup orientation was defined as inclination/anteversion of 40°/20° ± 10°. A change in orientation (Δinclination/Δanteversion) between postures > 5° was defined as clinically significant. Variability was defined as 2 x SD. RESULTS Inclination increased from 40° (supine) to 42° (standing) corresponding to a Δinclination of 2° (95% confidence interval [CI] 2-3). Anteversion increased from 25° (supine) to 30° (standing) corresponding to a Δanteversion of 5° (CI 5-6). When supine, 69% (CI 65-74) of THAs were within target, but only 44% (CI 39-49) were within target when standing, resulting in a further 26% (CI 21-30) being out of target when standing. From supine to standing, a clinically significant change in anteversion (> 5°) was seen in 47% (CI 42-52) of cases. Δanteversion was higher in women than in men (6°, CI 5-7 vs 5°, CI 4-5) corresponding to a difference of 1° (CI 1-2), which was dependent on tilt change, standing cup anteversion, age, and standing pelvic tilt. CONCLUSION Cup inclination and version increase upon standing but significant variability exists due to patient factors.
Collapse
Affiliation(s)
- Camille Vorimore
- Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada
| | - Jeroen C F Verhaegen
- Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada; University Hospital Antwerp, Edegem, Belgium; Orthopaedic Centre Antwerp, AZ Monica, Antwerp, Belgium
| | - Moritz Innmann
- Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada; Heidelberg University, Heidelberg, Germany
| | - A Paul Monk
- Auckland Surgical Centre, Auckland, New Zealand
| | | | | |
Collapse
|
2
|
Manzo MA, Lex JR, Rodriguez-Elizalde SR, Perlus R, Cayen B, Chang JS. Fluoroscopy Versus Imageless Optical Navigation in Direct Anterior Approach Total Hip Arthroplasty. J Am Acad Orthop Surg 2024; 32:e284-e292. [PMID: 38166193 DOI: 10.5435/jaaos-d-23-00790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 11/16/2023] [Indexed: 01/04/2024] Open
Abstract
BACKGROUND Utilization of the direct anterior approach (DAA) for total hip arthroplasty (THA) has risen in popularity. Accurate implant placement is a critical factor that influences patient outcomes. The goal of this study was to compare the accuracy and precision of fluoroscopy with imageless optical navigation in DAA THA. METHODS This was a cohort study of 640 consecutive primary DAA THAs performed with intraoperative fluoroscopy (n = 300 patients) or imageless optical navigation (n = 304 patients). Accuracy was compared by measuring acetabular cup inclination, anteversion, and leg-length discrepancy (LLD). The proportion of implants placed within the Lewinnek safe zone and those placed within a more precise target of 40 ± 5° inclination and 20 ± 5° anteversion was evaluated. RESULTS According to the Lewinnek criteria, there was no difference in the percentage of implants placed within both inclination and anteversion targets (fluoroscopy: 90.3%; navigation: 88.8%, P = 0.519). Using the more precise targets, navigation increased the implants positioned correctly for both inclination and anteversion (fluoroscopy: 50.3%; navigation: 65.6%, P < 0.001). Navigation increased the proportion of implants positioned within the target anteversion zone (fluoroscopy: 71.3%; navigation: 83.8%, P < 0.001) but not inclination (fluoroscopy: 71.9%; navigation: 76.9%, P = 0.147). The mean LLD was higher with the use of fluoroscopy compared with navigation (5.5 mm, standard deviation: 4.1; 4.6 mm, SD: 3.4, P < 0.005). No difference in dislocation rate was observed ( P = 0.643). CONCLUSION Both fluoroscopy and imageless optical navigation demonstrated accurate acetabular implant positioning during DAA THA. Navigation was more precise and associated with improved acetabular anteversion placement and restoration of LLD. Navigation is an accurate alternative to fluoroscopy with decreased radiation exposure.
Collapse
Affiliation(s)
- Marc A Manzo
- From the Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada (Manzo), the Department of Surgery, Division of Orthopaedic Surgery, Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada, (Lex, Rodriguez-Elizalde, Perlus, and Cayen, and Chang) and the Division of Orthopaedic Surgery, Humber River Hospital, Toronto, Ontario, Canada (Rodriguez-Elizalde, Perlus, Cayen, and Chang)
| | | | | | | | | | | |
Collapse
|
3
|
Panez-Toro I, Heymann D, Gouin F, Amiaud J, Heymann MF, Córdova LA. Roles of inflammatory cell infiltrate in periprosthetic osteolysis. Front Immunol 2023; 14:1310262. [PMID: 38106424 PMCID: PMC10722268 DOI: 10.3389/fimmu.2023.1310262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 11/13/2023] [Indexed: 12/19/2023] Open
Abstract
Classically, particle-induced periprosthetic osteolysis at the implant-bone interface has explained the aseptic loosening of joint replacement. This response is preceded by triggering both the innate and acquired immune response with subsequent activation of osteoclasts, the bone-resorbing cells. Although particle-induced periprosthetic osteolysis has been considered a foreign body chronic inflammation mediated by myelomonocytic-derived cells, current reports describe wide heterogeneous inflammatory cells infiltrating the periprosthetic tissues. This review aims to discuss the role of those non-myelomonocytic cells in periprosthetic tissues exposed to wear particles by showing original data. Specifically, we discuss the role of T cells (CD3+, CD4+, and CD8+) and B cells (CD20+) coexisting with CD68+/TRAP- multinucleated giant cells associated with both polyethylene and metallic particles infiltrating retrieved periprosthetic membranes. This review contributes valuable insight to support the complex cell and molecular mechanisms behind the aseptic loosening theories of orthopedic implants.
Collapse
Affiliation(s)
- Isidora Panez-Toro
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Dominique Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
- The University of Sheffield, Dept of Oncology and Metabolism, Sheffield, United Kingdom
| | - François Gouin
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France
| | - Jérôme Amiaud
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
| | - Marie-Françoise Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Luis A. Córdova
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- IMPACT, Center of Interventional Medicine for Precision and Advanced Cellular Therapy, Santiago, Chile
- Oral and Maxillofacial Surgery, Clínica MEDS, Santiago, Chile
| |
Collapse
|
4
|
Callary SA, Sharma DK, D’Apollonio TM, Campbell DG. Large articulations do not increase wear rates of thin second-generation highly cross-linked polyethylene liners at ten years. Bone Jt Open 2023; 4:839-845. [PMID: 37926113 PMCID: PMC10625862 DOI: 10.1302/2633-1462.411.bjo-2023-0124.r1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2023] Open
Abstract
Aims Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA. Methods We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point. Results The median proximal, 2D, and 3D wear rates calculated between one and ten years were all less than 0.005 mm/year, with no patient recording a proximal wear rate of more than 0.021 mm/year. Importantly, there was no increase in the wear rate between five and ten years. Conclusion The very low wear rate of X3 XLPE liners with larger articulations remains encouraging for the future clinical performance of this material.
Collapse
Affiliation(s)
- Stuart A. Callary
- Centre for Orthopaedic and Trauma Research, The University of Adelaide and Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia
| | - Deepti K. Sharma
- Centre for Orthopaedic and Trauma Research, The University of Adelaide and Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia
| | - Taisha M. D’Apollonio
- Centre for Orthopaedic and Trauma Research, The University of Adelaide, Adelaide, South Australia
| | | |
Collapse
|
5
|
Cheung A, Chan PK, Fu H, Cheung MH, Chan VWK, Luk MH, Chiu KY. Metal-on-crosslinked polyethylene in total hip arthroplasty - an excellent combination at fifteen to twenty years of follow-up. INTERNATIONAL ORTHOPAEDICS 2023; 47:2547-2552. [PMID: 37247019 DOI: 10.1007/s00264-023-05844-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 05/15/2023] [Indexed: 05/30/2023]
Abstract
PURPOSE Cross-linked polyethylene (PE) has been used with great clinical success in total hip arthroplasty (THA) since its debut in the late 1990's. However, reports regarding this bearing couple near the end of its second decade of service are still scant. The aim of this study was to first determine the long term clinical and radiological results and second Investigate what factors affect wear rates using a metal-on-crosslinked PE bearing articulation. METHODS 55 THAs using a single brand of cross-linked liner, cementless cup and 28 mm hip ball were performed in 44 patients. Age, sex, Charlson Comorbidity Index (CCI) and need for revision surgery were recorded. Linear and volumetric wear was determined using the Martell method. RESULTS Mean age at operation was 51.2 (29-73 ± 12.1) years. Mean duration of follow-up was 16.9 years (range 15.0-20.1 ± 1.1 years). Osteolysis was not present in the latest follow-up radiographs. Median linear and volumetric wear rate was 0.038 mm/year (95% CI 0.032-0.047) and 7.115mm3/year (95% CI 6.92-17.25) respectively. Acetabular component position was not found to be related to both linear and volumetric wear. No significant difference was found in the linear and volumetric wear rates of thinner and thicker liners (8 mm or below and > 8 mm) (p = 0.849 and p = 0.64 respectively). CONCLUSION Metal-on-crosslinked PE is associated with low linear and volumetric wear rates which has virtually obviated osteolysis and has translated to excellent survivorship even at long term follow up. In-vivo oxidation does not appear to be of clinical concern at this point.
Collapse
Affiliation(s)
- Amy Cheung
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China.
| | - Ping Keung Chan
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| | - Henry Fu
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| | - Man Hong Cheung
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| | - Vincent Wai Kwan Chan
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| | - Michelle Hilda Luk
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| | - Kwong-Yuen Chiu
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| |
Collapse
|
6
|
Fischer MCM, Tokunaga K, Okamoto M, Habor J, Radermacher K. Implications of the uncertainty of postoperative functional parameters for the preoperative planning of total hip arthroplasty. J Orthop Res 2022; 40:2656-2662. [PMID: 35266575 DOI: 10.1002/jor.25291] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 12/23/2021] [Accepted: 01/30/2022] [Indexed: 02/04/2023]
Abstract
The functional parameters pelvic tilt (PT) and hip joint force (HJF) are required to calculate patient-specific target zones based on the range of motion (ROM) and implant loading for preoperative planning of total hip arthroplasty (THA). Both functional parameters may change after THA. The preoperative prediction of the postoperative PT and HJF is associated with a specific amount of uncertainty. The prediction uncertainty has to be considered in the preoperative planning process to avoid a suboptimal implantation. So far, very little attention has been paid to the necessary reduction of patient-specific target zones by the prediction uncertainties of postoperative functional parameters. Prediction models for the postoperative PT in standing position and for the HJF during one-leg stance as a surrogate for the peak force phase during level walking were used to quantify the reduction of the ROM- and load-based target zones of 196 Japanese THA patients. The prediction uncertainty was about 14° for the postoperative standing PT and ranged from 17% body weight to 37% body weight for the components of the HJF. On average, the prosthetic ROM-based target zone had to be significantly reduced by 43% and the load-based target zone by 39%. This led to a median reduction of the combined prosthetic ROM- and load-based target zone of 96%. The study sharpens the awareness for the substantial reduction of ROM- and load-based target zones by prediction uncertainties of the postoperative PT and HJF and highlights the importance of further research to improve prediction models for both functional parameters.
Collapse
Affiliation(s)
- Maximilian C M Fischer
- Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| | - Kunihiko Tokunaga
- Niigata Hip Joint Center, Kameda Daiichi Hospital, Niigata City, Japan
| | - Masashi Okamoto
- Department of Radiology, Kameda Daiichi Hospital, Niigata City, Japan
| | - Juliana Habor
- Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| | - Klaus Radermacher
- Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
7
|
Does accelerometer-based portable navigation provide more accurate and precise cup orientation without prosthetic impingement than conventional total hip arthroplasty? A randomized controlled study. Int J Comput Assist Radiol Surg 2022; 17:1007-1015. [DOI: 10.1007/s11548-022-02592-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 03/04/2022] [Indexed: 11/05/2022]
|
8
|
江 旭, 张 恒, 胡 旭, 谢 凯, 阚 天, 李 波, 张 弛, 艾 松, 高 梁, 严 孟, 王 燎. [Semi-automated measurement and analysis of three-dimensional acetabular orientation in asymptomatic population and patients of developmental dysplasia of the hip]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2021; 35:1555-1562. [PMID: 34913312 PMCID: PMC8669196 DOI: 10.7507/1002-1892.202107112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 10/24/2021] [Indexed: 11/03/2022]
Abstract
OBJECTIVE To evaluate the three-dimensional acetabular orientation in asymptomatic population and patients of developmental dysplasia of the hip (DDH) using a semi-automated measurement software, which provides data for the differential diagnosis, surgical planning, surgical instrument design, and postoperative evaluation of hip related diseases. METHODS Eighty-four cases of CT data in asymptomatic population (asymptomatic group) and 47 cases of CT data in DDH patients (DDH group) were collected. There was no significant difference in gender and age (including age of male and female subgroups) between the two groups ( P<0.05). MaxTHA, a semi-automatic measurement software, was used to measure acetabular inclination and anteversion, including operative inclination (OI), radiographic inclination (RI), anatomic inclination (AI), operative anteversion (OA), radiographic anteversion (RA), and anatomic anteversion (AA). Comparisons were made between the two populations, between different Crowe classification subgroups, between different gender subgroups, and between left and right sides of acetabula. RESULTS The comparison between asymptomatic group, healthy side of DDH group, and affected side of DDH group showed that there was no significant difference in acetabular orientation between asymptomatic group and healthy side of DDH group ( P>0.05). The OI, RI, and AI of affected side of DDH group were significantly higher than those in healthy side of DDH group and asymptomatic group, and AA was significantly lower than that in healthy side of DDH group and asymptomatic group ( P<0.05). The comparison between the normal acetabula and DDH acetabula with different Crowe classifications showed that there was no significant difference in the acetabulum orientation between Crowe Ⅰ group and the normal group ( P>0.05). The OI, RI, and AI of Crowe Ⅱ, Ⅲ, and Ⅳ groups were significantly higher than those of normal group ( P<0.05), the OI of Crowe Ⅲ group, RI and AI of Crowe Ⅳ group were significantly higher than those of Crowe Ⅰ group ( P<0.05), the AI of Crowe Ⅳ group was significantly higher than that of Crowe Ⅱ group ( P<0.05), and the OA, RA, and AA of Crowe Ⅲ group were significantly lower than other subgroups ( P<0.05) except Crowe Ⅰ group. The OA, RA, and AA in asymptomatic female group, and the OA and AI in DDH female group were significantly higher than those in all male groups ( P<0.05). The OI, RI, AI, and OA of the right acetabula in asymptomatic male group, and the RI and AI of the right acetabula in asymptomatic female group were significantly higher than those on the left side ( P<0.05). CONCLUSION There were significant differences in acetabular orientation between asymptomatic and DDH populations, inter-group differences among Crowe classification subgroups, inter-gender differences among subgroups, and bilateral differences among asymptomatic individuals.
Collapse
Affiliation(s)
- 旭 江
- 上海交通大学医学院附属第九人民医院骨科 上海市骨科内植物重点实验室(上海 200011)Department of Orthopedics, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, P.R.China
- 中山大学孙逸仙纪念医院骨科(广州 510120)Department of Orthopedics, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou Guangdong, 510120, P.R.China
| | - 恒辉 张
- 上海交通大学医学院附属第九人民医院骨科 上海市骨科内植物重点实验室(上海 200011)Department of Orthopedics, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, P.R.China
| | - 旭民 胡
- 上海交通大学医学院附属第九人民医院骨科 上海市骨科内植物重点实验室(上海 200011)Department of Orthopedics, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, P.R.China
| | - 凯 谢
- 上海交通大学医学院附属第九人民医院骨科 上海市骨科内植物重点实验室(上海 200011)Department of Orthopedics, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, P.R.China
| | - 天佑 阚
- 上海交通大学医学院附属第九人民医院骨科 上海市骨科内植物重点实验室(上海 200011)Department of Orthopedics, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, P.R.China
| | - 波 李
- 上海交通大学医学院附属第九人民医院骨科 上海市骨科内植物重点实验室(上海 200011)Department of Orthopedics, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, P.R.China
| | - 弛 张
- 上海交通大学医学院附属第九人民医院骨科 上海市骨科内植物重点实验室(上海 200011)Department of Orthopedics, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, P.R.China
| | - 松涛 艾
- 上海交通大学医学院附属第九人民医院骨科 上海市骨科内植物重点实验室(上海 200011)Department of Orthopedics, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, P.R.China
| | - 梁斌 高
- 上海交通大学医学院附属第九人民医院骨科 上海市骨科内植物重点实验室(上海 200011)Department of Orthopedics, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, P.R.China
| | - 孟宁 严
- 上海交通大学医学院附属第九人民医院骨科 上海市骨科内植物重点实验室(上海 200011)Department of Orthopedics, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, P.R.China
| | - 燎 王
- 上海交通大学医学院附属第九人民医院骨科 上海市骨科内植物重点实验室(上海 200011)Department of Orthopedics, Shanghai Key Laboratory of Orthopaedic Implants, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, P.R.China
| |
Collapse
|
9
|
Goyal T, Paul S, Choudhury AK, Gupta T. Assessment of Acetabular Component Anteversion after Total Hip Arthroplasty: Comparison of Anteroposterior and Cross-Table Lateral Radiographs with Computed Tomography Scans. Clin Orthop Surg 2021; 13:329-335. [PMID: 34484625 PMCID: PMC8380526 DOI: 10.4055/cios20274] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 12/19/2020] [Accepted: 12/28/2020] [Indexed: 11/29/2022] Open
Abstract
Background Several methods of measurement of anteversion of acetabular components after total hip arthroplasty (THA) have been described in the literature using plain radiographs or computed tomography (CT) scans. None of these have proved to be the gold standard. We aimed to study the correlation between the CT and radiographic methods of calculation of acetabulum anteversion. Methods CT scans of the pelvis, anteroposterior (AP) and cross-table lateral (CL) radiographs were obtained in 60 patients who underwent THA two weeks after surgery. Anteversion was measured using Widmer method and Liaw method on AP radiographs, and the ischiolateral method on CL radiographs. Anteversion measured on the CT scan was taken as the reference anteversion and the above measurements were analysed for correlation with the measurements on CT scan. Intraclass correlation coefficients (ICCs) were calculated for both intra- and interobserver reliability. Results Mean acetabular version on CL radiographs was 53.1 ± 10.7. Mean version on AP radiographs by Widmer method was 21.4 ± 3.6 and by Liaw method was 20.3 ± 4.8. Mean version on CT scans was 26.02 ± 6.8. There was a good correlation between the acetabular version on CT scans with the version on AP radiographs by Widmer method (r = 0.78, p < 0.001) and Liaw method (r = 0.87, p < 0.001). Good correlation was seen between the acetabular version on CL radiographs and CT scans (r = 0.91, p < 0.001). Also, a good correlation was observed between the acetabular version measurements on CL radiographs and AP radiographs by Widmer method (r = 0.81, p < 0.001) or Liaw method (r = 0.70, p < 0.001). Excellent inter- and intraobserver reliability were seen for all the measurements. Conclusions Calculation of acetabular component version on AP views as well as CL views of plain radiographs showed a strong correlation with the version measurements on CT scans. Good correlations were observed between different techniques of measurement on radiographs. Therefore, all these measurements can be valid methods for assessment of anteversion.
Collapse
Affiliation(s)
- Tarun Goyal
- Department of Orthopaedics, All India Institute of Medical Sciences, Bathinda, India
| | - Souvik Paul
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, India
| | | | - Tushar Gupta
- Department of Orthopaedics, All India Institute of Medical Sciences, Rishikesh, India
| |
Collapse
|
10
|
Tetsunaga T, Yamada K, Tetsunaga T, Furumatsu T, Sanki T, Kawamura Y, Ozaki T. Comparison of the accuracy of CT- and accelerometer-based navigation systems for cup orientation in total hip arthroplasty. Hip Int 2021; 31:603-608. [PMID: 32019376 DOI: 10.1177/1120700020904940] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND The accuracies of various navigation systems in total hip arthroplasty (THA) have been described; however, the accuracy of cup orientation with an accelerometer-based navigation system has not been reported. The purpose of this study was to compare the accuracies of computed tomography (CT)- and accelerometer-based navigation systems for cup orientation in THA. METHODS In this prospective study, 30 patients who underwent cementless THA via anterolateral approach in the lateral decubitus position were analysed. A CT-based navigation system (30 hips) and an accelerometer-based navigation system (30 hips) were used simultaneously. The accuracy of cup orientation (absolute difference between intraoperative vs. postoperative measurements) was compared between the navigation systems using postoperative CT. RESULTS The accuracy of cup inclination was 3.2 ± 2.4° in the CT-based navigation group and 4.1 ± 3.7° in the accelerometer-based navigation group (p = 0.3035). The accuracy of cup anteversion was 3.0° ± 2.5° in the CT-based navigation group and 6.8° ± 4.8° in the accelerometer-based navigation group. Cup anteversion was significantly more accurate with the CT-based navigation system than with accelerometer-based navigation (p = 0.0009). Multiple regression analysis demonstrated that the malposition in cup anteversion was positively correlated with the change in pelvic tilt and loosening of the reference antenna. CONCLUSIONS Although, these results are only true for this specific accelerometer system, cup positioning was significantly more accurate with the CT-based navigation system than an accelerometer-based navigation in the lateral decubitus position. This is because of considerable discrepancies in the sagittal pelvic tilt, resulting in variability in cup anteversion angle with the use of an accelerometer-based navigation system.
Collapse
Affiliation(s)
| | - Kazuki Yamada
- Department of Orthopaedics, Okayama University Hospital, Okayama, Japan
| | - Tomoko Tetsunaga
- Department of Orthopaedics, Okayama University Hospital, Okayama, Japan
| | | | - Tomoaki Sanki
- Department of Orthopaedics, Okayama University Hospital, Okayama, Japan
| | - Yoshi Kawamura
- Department of Orthopaedics, Okayama University Hospital, Okayama, Japan
| | - Toshifumi Ozaki
- Department of Orthopaedics, Okayama University Hospital, Okayama, Japan
| |
Collapse
|
11
|
Song SK, Choi WK, Jung SH, Kim HC, Kim TH, Cho MR. Changes of acetabular anteversion according to pelvic tilt on sagittal plane under various acetabular inclinations. J Orthop Res 2021; 39:806-812. [PMID: 32603527 DOI: 10.1002/jor.24790] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 06/15/2020] [Accepted: 06/24/2020] [Indexed: 02/04/2023]
Abstract
Improper functional orientation of the acetabular cup can result in improper positions when dynamic pelvic positions are not considered. The purpose of this study was to evaluate changes on acetabular anteversion according to pelvic tilt under various acetabular inclinations. Two artificial pelvic models were selected for this study. Acetabular inclinations on the coronal plane were 25°, 32°, 50°, and 60°. Acetabular anteversion of all components were 15°. Changes of anteversion according to pelvic tilt were measured at angles of 0°, 10°, 20°, 30°, and 40°. Computer Navigation, PolyWare 3D pro, CT, and plain radiography were used to measure each angle. The anatomical anteversions against pelvic tilt were calculated using the following formulae: anatomical anteversion (°) = -14.48Χ + 90.18 (inclination angle 25°); anatomical anteversion (°) = -12.26Χ + 80.10 (inclination angle 32°); anatomical anteversion (°) = -7.468Χ + 61.13 (inclination angle 50°); and anatomical anteversion (°) = -5.328Χ + 44.84 (inclination angle 60°) (Χ: pelvic tilt angle). Radiographic anteversion against pelvic tilt were calculated using the following formulae: radiographic anteversion (°) = -9.50Χ + 57.09 (inclination angle 25°); radiographic anteversion (°) = -8.577Χ + 50.89 (inclination angle 32°); radiographic anteversion (°) = -6.794Χ + 45.73 (inclination angle 50°); radiographic anteversion (°) = -5.226Χ + 33.08 (inclination angle 60°). In conclusion, changes in anteversion according to pelvic tilt were lesser at higher degrees of acetabular inclination.
Collapse
Affiliation(s)
- Suk Kyoon Song
- Department of Orthopedics, Daegu Catholic University Medical Center, Daegu, South Korea
| | - Won Kee Choi
- Department of Orthopedics, Daegu Catholic University Medical Center, Daegu, South Korea
| | - Suk Han Jung
- Department of Orthopedics, Daegu Catholic University Medical Center, Daegu, South Korea
| | - Hee Chan Kim
- Department of Orthopedics, Daegu Catholic University Medical Center, Daegu, South Korea
| | - Tae Hoon Kim
- Department of Orthopedics, Suseong Metro Hospital, Daegu, South Korea
| | - Myung Rae Cho
- Department of Orthopedics, Daegu Catholic University Medical Center, Daegu, South Korea
| |
Collapse
|
12
|
Fischer MCM, Tokunaga K, Okamoto M, Habor J, Radermacher K. Preoperative factors improving the prediction of the postoperative sagittal orientation of the pelvis in standing position after total hip arthroplasty. Sci Rep 2020; 10:15944. [PMID: 32994419 PMCID: PMC7524714 DOI: 10.1038/s41598-020-72782-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Accepted: 09/02/2020] [Indexed: 11/09/2022] Open
Abstract
The aims of this study were to investigate if the sagittal orientation of the pelvis (SOP) in the standing position changes after total hip arthroplasty (THA) and evaluate what preoperative factors may improve the prediction of the postoperative standing SOP in the context of a patient-specific functional cup orientation. 196 primary THA patients from Japan were retrospectively selected for this study. Computed tomography imaging of the pelvis, EOS imaging of the lower body and lateral radiographs of the lumbar spine in the standing position were taken preoperatively. Common biometrics and preoperative Harris Hip Score were recorded. The EOS imaging in the standing position was repeated three months following THA. A 3D/2.5D registration process was used to determine the standing SOP. Thirty-three preoperative biometric, morphological and functional parameters were measured. Important preoperative parameters were identified that significantly improve the prediction of the postoperative standing SOP by using multiple linear LASSO regression. On average, the SOP changed significantly (p < 0.001) between the preoperative and postoperative standing position three months after THA by 3° ± 4° in the posterior direction. The age, standing lumbar lordosis angle (LLA) and preoperative supine and standing SOP significantly (p < 0.001) improve the prediction of the postoperative standing SOP. The linear regression model for the prediction of the postoperative standing SOP is significantly (p < 0.001) improved by adding the parameters preoperative standing SOP and LLA, in addition to the preoperative supine SOP, reducing the root mean square error derived from a leave-one-out cross-validation by more than 1°. The mean standing SOP in Japanese patients changes already three months after THA in comparison to the preoperative value. The preoperative factors age, LLA, supine and standing SOP can significantly improve the prediction of the postoperative standing SOP and should be considered within the preoperative planning process of a patient-specific functional cup orientation.
Collapse
Affiliation(s)
- Maximilian C M Fischer
- Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany.
| | - Kunihiko Tokunaga
- Niigata Hip Joint Center, Kameda Daiichi Hospital, Niigata City, Japan
| | - Masashi Okamoto
- Department of Radiology, Kameda Daiichi Hospital, Niigata City, Japan
| | - Juliana Habor
- Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| | - Klaus Radermacher
- Chair of Medical Engineering, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
13
|
Tetsunaga T, Yamada K, Tetsunaga T, Sanki T, Kawamura Y, Ozaki T. An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position. J Orthop Surg Res 2020; 15:147. [PMID: 32295628 PMCID: PMC7161129 DOI: 10.1186/s13018-020-01673-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Accepted: 04/03/2020] [Indexed: 11/21/2022] Open
Abstract
Background Inadequate acetabular component orientation is associated with postoperative impingement, dislocation, and accelerated polyethylene wear. Computed tomography (CT)-based navigation systems provide accuracy for total hip arthroplasty (THA) but are not available in all facilities. Accelerometer-based navigation systems are inexpensive, but their accuracy remains undetermined. This study compares the accuracy of cup orientation in THA using CT-based and accelerometer-based navigation systems. Methods This retrospective study included 35 consecutive patients (11 males, 24 females; mean age, 65 years) who underwent primary cementless THA via an anterolateral approach in the supine position. Both CT-based and accelerometer-based navigation systems were used simultaneously. The accuracy of cup orientation was compared between the two systems using postoperative CT. Results The accuracy of cup inclination was 2.7° ± 2.0° in the CT-based group and 3.3° ± 2.4° in the accelerometer-based group. The accuracy of cup anteversion was 2.8° ± 2.6° in the CT-based group and 3.4° ± 2.2° in the accelerometer-based group. No significant difference was observed in cup inclination (p = 0.29) or cup anteversion (p = 0.34) between CT-based and accelerometer-based navigation. Conclusions The accuracy of cup positioning did not differ significantly between CT-based and accelerometer-based navigation systems.
Collapse
Affiliation(s)
- Tomonori Tetsunaga
- Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikata-cho, Kitaku, Okayama, 700-8558, Japan.
| | - Kazuki Yamada
- Department of Medical Materials for Musculoskeletal Reconstruction, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kitaku, Okayama, 700-8558, Japan
| | - Tomoko Tetsunaga
- Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikata-cho, Kitaku, Okayama, 700-8558, Japan
| | - Tomoaki Sanki
- Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikata-cho, Kitaku, Okayama, 700-8558, Japan
| | - Yoshi Kawamura
- Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikata-cho, Kitaku, Okayama, 700-8558, Japan
| | - Toshifumi Ozaki
- Department of Orthopaedic Surgery, Okayama University Hospital, 2-5-1 Shikata-cho, Kitaku, Okayama, 700-8558, Japan
| |
Collapse
|
14
|
Zhao JX, Su XY, Zhao Z, Xiao RX, Zhang LC, Tang PF. Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:130. [PMID: 32175423 DOI: 10.21037/atm.2019.12.150] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Optimal acetabular cup orientation is of substantial importance to good long-term function and low complication rates after total hip arthroplasty (THA). The radiographic anteversion (RA) and inclination (RI) angles of the cup are typically studied due to the practicability, simplicity, and ease of interpretation of their measurements. A great number of methods have been developed to date, most of which have been performed on pelvic or hip anteroposterior radiographs. However, there are primarily two influencing factors for these methods: X-ray offset and pelvic rotation. In addition, there are three types of pelvic rotations about the transverse, longitudinal, and anteroposterior axes of the body. Their effects on the RA and RI angles of the cup are interactively correlated with the position and true orientation of the cup. To date, various fitted or analytical models have been established to disclose the correlations between the X-ray offset and pelvic rotation and the RA and RI angles of the cup. Most of these models do not incorporate all the potential influencing parameters. Advanced methods for performing X-ray offset and pelvic rotation corrections are mainly performed on a single pelvic AP radiograph, two synchronized radiographs, or a two-dimensional/three-dimensional (2D-3D) registration system. Some measurement systems, originally developed for evaluating implant migration or wear, could also be used for correcting the X-ray offset and pelvic rotation simultaneously, but some drawbacks still exist with these systems. Above all, the 2D-3D registration technique might be an alternative and powerful tool for accurately measuring cup orientation. In addition to the current methods used for postoperative assessment, navigation systems and augmented reality are also used for the preoperative planning and intraoperative guidance of cup placement. With the continuing development of artificial intelligence and machine learning, these techniques could be incorporated into robot-assisted orthopaedic surgery in the future.
Collapse
Affiliation(s)
- Jing-Xin Zhao
- Department of Orthopaedics, the First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China.,National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing 100853, China
| | - Xiu-Yun Su
- Department of Orthopaedics, the First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China.,Intelligent and Digital Surgery Innovation Center, Southern University of Science and Technology Hospital, Shenzhen, Guangdong 518055, China
| | - Zhe Zhao
- Department of Orthopaedics, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing 102218, China
| | - Ruo-Xiu Xiao
- School of Computer and Communication Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Li-Cheng Zhang
- Department of Orthopaedics, the First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China.,National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing 100853, China
| | - Pei-Fu Tang
- Department of Orthopaedics, the First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China.,National Clinical Research Center for Orthopedics, Sports Medicine & Rehabilitation, Beijing 100853, China
| |
Collapse
|
15
|
Abstract
Preoperative planning is mandatory to achieve the restoration of a correct and personalized biomechanics of the hip. The radiographic review is the first and fundamental step in the planning. Limb or pelvis malpositioning during the review results in mislead planning. Correct templating is possible using three different methods: acetate templating on digital X-ray, digital 2D templating on digital X-ray and 3D digital templating on CT scan. Time efficiency, costs, reproducibility and accuracy must be considered when comparing different templating methods. Based on these parameters, acetate templating should not be abandoned; digital templating allows a permanent record of planning and can be electronically viewed by different members of surgical team; 3D templating is intrinsically more accurate. There is no evidence in the few recently published studies that 3D templating impacts positively on clinical outcomes except in difficult cases. The transverse acetabular ligament (TAL) is a reliable intraoperative soft tissue reference to set cup position. Spine–hip relations in osteoarthritic patients undergoing hip joint replacement must be considered.
Cite this article: EFORT Open Rev 2019;4:626-632. DOI: 10.1302/2058-5241.4.180075
Collapse
Affiliation(s)
- Alessandro Colombi
- Department of Orthopaedic Surgery, ASST Papa Giovanni XXIII, Bergamo, Italy
| | - Daniele Schena
- Department of Orthopaedic Surgery, ASST Papa Giovanni XXIII, Bergamo, Italy
| | | |
Collapse
|
16
|
Cheung A, Yan CH, Fu H, Cheung MH, Chan PK, Chiu KY. Ten- to Sixteen-Year Follow-Up of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: What Factors Affect Wear? J Arthroplasty 2019; 34:2016-2021. [PMID: 31176564 DOI: 10.1016/j.arth.2019.04.041] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Revised: 04/16/2019] [Accepted: 04/22/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Increase in acetabular cup abduction in total hip arthroplasty (THA) using conventional polyethylene is associated with greater linear wear. Whether this relationship holds true for highly crosslinked liners, particularly with long-term follow-up, is still controversial. The effect of liner thickness on wear of highly cross-linked liners also remains to be clarified.This study sought to determine (1) the long-term clinical and radiological performance of highly cross-linked polyethylene in THA and (2) the effect of acetabular component positioning, polyethylene thickness, and patient demographics on wear. METHODS Ninety-three THAs using a 28-mm hip ball, single brand of highly cross-linked polyethylene liner, and cementless cup were performed in 87 patients. Clinical outcomes were evaluated using the Harris Hip Score and need for revision surgery. Linear and volumetric wear, presence of osteolysis, and cup abduction angle were assessed. RESULTS The mean age at operation was 51.4 years. The mean duration of follow-up was 12.7 years (10-16 years). Patients aged >50 years had higher rates of linear wear than those aged <50 years (P = .015). Positive correlation was found between cup abduction angle (P = .014) and cup version (P = .035) with a linear wear rate. Thinner liners (≤7 mm) had similar rates of linear and volumetric wear as thicker liners (≥8 mm) (P = .447). CONCLUSION This is the only study to demonstrate a positive significant relationship between cup abduction angle and version with linear wear rate in THA with at least 10 years of follow-up. Liner thickness was not found to affect wear rates.
Collapse
Affiliation(s)
- Amy Cheung
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, Hong Kong SAR, China
| | - Chun Hoi Yan
- Department of Orthopaedics and Traumatology, University of Hong Kong, Hong Kong, Hong Kong SAR, China
| | - Henry Fu
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, Hong Kong SAR, China
| | - Man Hong Cheung
- Department of Orthopaedics and Traumatology, University of Hong Kong, Hong Kong, Hong Kong SAR, China
| | - Ping Keung Chan
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, Hong Kong SAR, China
| | - Kwong Yuen Chiu
- Department of Orthopaedics and Traumatology, University of Hong Kong, Hong Kong, Hong Kong SAR, China
| |
Collapse
|
17
|
Bradley MP, Benson JR, Muir JM. Accuracy of Acetabular Component Positioning Using Computer-assisted Navigation in Direct Anterior Total Hip Arthroplasty. Cureus 2019; 11:e4478. [PMID: 31249755 PMCID: PMC6579332 DOI: 10.7759/cureus.4478] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Accepted: 04/16/2019] [Indexed: 02/06/2023] Open
Abstract
Background Appropriate component positioning in total hip arthroplasty (THA) is imperative for long-term survivorship. C-arm fluoroscopy provides visual guidance in the direct anterior approach (DAA), but it is limited by qualitative properties. Conversely, imageless computer-assisted navigation systems (CAS) provide surgeons with intraoperative, three-dimensional (3D) quantitative measurements for cup position, although the accuracy of such systems has not been extensively addressed in the DAA. We evaluated the ability of an imageless CAS to deliver measurements for acetabular cup position with accuracy in the DAA. Materials and methods A retrospective analysis of 69 primary THA procedures was conducted. Acetabular cup position measurements (anteversion and inclination) obtained intraoperatively by imageless navigation were compared to standard, postoperative anteroposterior pelvic radiographic measurements. Statistical comparisons were made using the Bland-Altman technique. Results The mean difference between device and radiographic measurements for anteversion was 3.4° (standard deviation (SD): 4.1°; absolute mean difference (ABS): 4.2°), and 4.0° for inclination (SD: 3.6°; ABS: 4.3°). Bland-Altman analysis demonstrated excellent agreement; 93% (64/69) and 97% (67/69) of anteversion pairings fell within the statistical and clinical limits of agreement, whereas 94% (65/69) and 100% (69/69) of inclination pairings were within the statistical and clinical limits, respectively. Conclusions Measurements obtained intraoperatively for acetabular cup position using imageless navigation in the DAA are agreeable with the current clinical standard.
Collapse
|
18
|
Teeter MG, Lanting BA, Naudie DD, McCalden RW, Howard JL, MacDonald SJ. Highly crosslinked polyethylene wear rates and acetabular component orientation: a minimum ten-year follow-up. Bone Joint J 2018; 100-B:891-897. [PMID: 29954202 DOI: 10.1302/0301-620x.100b7.bjj-2017-1457.r3] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Aims The aim of this study was to determine whether there is a difference in the rate of wear between acetabular components positioned within and outside the 'safe zones' of anteversion and inclination angle. Patients and Methods We reviewed 100 hips in 94 patients who had undergone primary total hip arthroplasty (THA) at least ten years previously. Patients all had the same type of acetabular component with a bearing couple which consisted of a 28 mm cobalt-chromium head on a highly crosslinked polyethylene (HXLPE) liner. A supine radiostereometric analysis (RSA) examination was carried out which acquired anteroposterior (AP) and lateral paired images. Acetabular component anteversion and inclination angles were measured as well as total femoral head penetration, which was divided by the length of implantation to determine the rate of polyethylene wear. Results The mean anteversion angle was 19.4° (-15.2° to 48°, sd 11.4°), the mean inclination angle 43.4° (27.3° to 60.5°, sd 6.6°), and the mean wear rate 0.055 mm/year (sd 0.060). Exactly half of the hips were positioned inside the 'safe zone'. There was no difference (median difference, 0.012 mm/year; p = 0.091) in the rate of wear between acetabular components located within or outside the 'safe zone'. When compared to acetabular components located inside the 'safe zone', the wear rate was no different for acetabular components that only achieved the target anteversion angle (median difference, 0.012 mm/year; p = 0.138), target inclination angle (median difference, 0.013 mm/year; p = 0.354), or neither target (median difference, 0.012 mm/year; p = 0.322). Conclusion Placing the acetabular component within or outside the 'safe zone' did not alter the wear rate of HXLPE at long-term follow-up to a level that risked osteolysis. HXLPE appears to be a forgiving bearing material in terms of articular surface wear, but care must still be taken to position the acetabular component correctly so that the implant is stable. Cite this article: Bone Joint J 2018;100-B:891-7.
Collapse
Affiliation(s)
- M G Teeter
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - B A Lanting
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - D D Naudie
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - R W McCalden
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - J L Howard
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - S J MacDonald
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| |
Collapse
|
19
|
Broberg JS, Yuan X, Teeter MG. Radiostereometric analysis using clinical radiographic views: Development of a universal calibration object. J Biomech 2018; 73:238-242. [PMID: 29628133 DOI: 10.1016/j.jbiomech.2018.03.033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Revised: 02/14/2018] [Accepted: 03/21/2018] [Indexed: 11/24/2022]
Abstract
Radiostereometric analysis (RSA) is a highly accurate technique used to provide three-dimensional (3D) measurements of orthopaedic implant migration for clinical research applications, yet its implementation in routine clinical examinations has been limited. Previous studies have introduced a modified RSA procedure that separates the calibration examinations from the patient examinations, allowing routine clinical radiographs to be analyzed using RSA. However, in order to calibrate the wide range of clinical views, a new calibration object is required. In this study, a universal, isotropic calibration object was designed to calibrate any pair of radiographic views used in the clinic for RSA. A numerical simulation technique was used to design the calibration object, followed by a phantom validation test of a prototype to verify the performance of the novel object, and to compare the measurement reliability to the conventional calibration cage. The 3D bias for the modified calibration method using the new calibration object was 0.032 ± 0.006 mm, the 3D repeatability standard deviation was 0.015 mm, and the 3D repeatability limit was 0.042 mm. Although statistical differences were present between the universal calibration object and the conventional cage, the differences were considered to be not clinically meaningful. The 3D bias and repeatability values obtained using the universal calibration object were well under the threshold acceptable for RSA, therefore it was successfully validated. The universal calibration object will help further the adoption of RSA into a more routine practice, providing the opportunity to generate quantitative databases on joint replacement performance.
Collapse
Affiliation(s)
- Jordan S Broberg
- Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, Canada
| | - Xunhua Yuan
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine & Dentistry, Western University, Canada.
| | - Matthew G Teeter
- Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, Canada; Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine & Dentistry, Western University, Canada; Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine & Dentistry, Western University, Canada; Surgical Innovation Program, Lawson Health Research Institute, Canada
| |
Collapse
|