1
|
Ishii S, Baba T, Shirogane Y, Hayashi K, Homma Y, Muto O, Kaneko K, Ishijima M. Callus formation after total hip arthroplasty using a short tapered-wedge stem. Skeletal Radiol 2024:10.1007/s00256-024-04756-7. [PMID: 39052073 DOI: 10.1007/s00256-024-04756-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 07/16/2024] [Accepted: 07/16/2024] [Indexed: 07/27/2024]
Abstract
OBJECTIVE The incidence of periprosthetic fractures after total hip arthroplasty using a short tapered-wedge stem is high. Callus formation preceding this fracture, which indicates postoperative stress fracture around the stem, has been reported. However, previous studies on postoperative callus are limited. Hence, the current study aimed to evaluate the prevalence and risk factors of postoperative callus after total hip arthroplasty with a short tapered-wedge stem. MATERIALS AND METHODS This retrospective study included 127 patients who underwent total hip arthroplasty using a cementless short tapered-wedge stem. The depth of stem insertion was measured as the distance from the lateral corner of the stem to the most medial point of the lesser trochanter along the body axis. Postoperative callus was defined as a bridging callus on the lateral femoral cortex at the distal end of the porous coating of the stem. Plain radiography was performed before surgery and immediately and at 1, 3, and 6 months after surgery to assess postoperative callus. Univariate and multivariate logistic regression analyses were performed to identify the risk factors for PC. RESULTS In total, 60 (47.2%) of 127 patients presented with postoperative callus. Multivariate logistic regression analysis with postoperative callus as the dependent variable revealed that the stem depth at 1 month after total hip arthroplasty (odds ratio, 1.14; 95% confidence interval, 1.04-1.24, p = 0.002) was a significant and independent risk factor of postoperative callus. CONCLUSION Deep insertion of a short tapered-wedge stem is a risk factor for postoperative callus.
Collapse
Affiliation(s)
- Seiya Ishii
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan.
- Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan.
- Department of Orthopaedic Surgery, Yokohama Tsurugamine Hospital, Kanagawa, Japan.
| | - Tomonori Baba
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan
- Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan
| | - Yuichi Shirogane
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan
- Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan
| | - Koju Hayashi
- Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan
| | - Yasuhiro Homma
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan
- Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan
| | - Osamu Muto
- Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan
- Department of Orthopaedic Surgery, Yokohama Tsurugamine Hospital, Kanagawa, Japan
| | - Kazuo Kaneko
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan
- Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan
| | - Muneaki Ishijima
- Department of Medicine for Orthopaedics and Motor Organ, Juntendo University Graduate School of Medicine, Tokyo, Japan
- Department of Orthopaedics, Faculty of Medicine, Juntendo University, Tokyo, Japan
| |
Collapse
|
2
|
Baldwin TJ, Deckard ER, Buller LT, Meneghini RM. Incidence and Predictors of Subsidence Using Modular, Tapered, Fluted Titanium Femoral Stems in Aseptic Revision Total Hip Arthroplasty. J Arthroplasty 2024; 39:1304-1311. [PMID: 37924992 DOI: 10.1016/j.arth.2023.10.057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/27/2023] [Accepted: 10/30/2023] [Indexed: 11/06/2023] Open
Abstract
BACKGROUND Tapered, fluted titanium (TFT) femoral stems have become the gold standard in revision total hip arthroplasty (rTHA). However, there is a paucity of data on TFT stem subsidence rates following aseptic rTHA. Subsidence can lead to instability, mechanical failure, leg-length discrepancy, and may require revision surgery. This study evaluated the incidences and predictors of TFT subsidence in aseptic rTHA. METHODS A total of 102 TFT femoral stems of 4 designs were retrospectively reviewed. Stem subsidence was measured on digital radiographs taken immediately after surgery and at standard clinical follow-up. Patient characteristics, risk factors for subsidence, revision etiologies, and implant characteristics were recorded. Patient-reported outcome measures were also evaluated for a subset of cases. RESULTS Overall, 12% of stems subsided >1 cm, and subsidence was minimal (<3 mm) in ≥64% of cases. From immediate postoperative to 1-month radiographic follow-up, 79% of stems subsided a mean of 2.9 mm (range, 0.1 to 12 mm). Beyond 1 month, subsidence was minimal for ≥77% of cases. In multivariate analyses, women and less femoral implant canal fill were associated with greater subsidence (P ≤ .034). The TFT stem design was not associated with early subsidence (P = .816). There were no modular junction fractures. There were 2 fractures and 2 subsidence-related revisions for aseptic loosening that occurred postoperatively. CONCLUSIONS The amount of subsidence in TFT stems was low and was detectable in the early (less than 1 year) postoperative period. Maximizing TFT stem fill within the femoral canal appears to reduce the risk of subsidence without increasing femoral fracture rates and should be the goal with implantation of these devices. LEVEL OF EVIDENCE IV-Case Series, No Control Group.
Collapse
Affiliation(s)
- Thomas J Baldwin
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana
| | - Evan R Deckard
- Indiana Joint Replacement Institute, Indianapolis, Indiana
| | - Leonard T Buller
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana
| | - R Michael Meneghini
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana; Indiana Joint Replacement Institute, Indianapolis, Indiana
| |
Collapse
|
3
|
Hunter M, Fawley DW, Diaz R, Barrett W, Croker S, Gorab R. Five-Year Survivorship of Total Hip Arthroplasty With a Proximally Coated, Medially Collared, Triple-Tapered Femoral Stem: A Retrospective, Multicenter Registry Review. Cureus 2024; 16:e59462. [PMID: 38826998 PMCID: PMC11141789 DOI: 10.7759/cureus.59462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/30/2024] [Indexed: 06/04/2024] Open
Abstract
Background The anterior approach for total hip arthroplasty (THA) has gained popularity in recent years. Some surgeons have been hesitant to adopt the approach due to concerns over increased complications such as intraoperative fracture, stem loosening, and stem revision. This study aims to evaluate the all-cause revision rate and survivorship of a collared, triple-tapered stem that was designed specifically for use with the anterior approach in THA to enhance outcomes and reduce adverse events. Methodology A retrospective outcomes review was conducted to assess survivorship and clinical outcomes for a specific proximally coated, medially collared triple-tapered (MCTT) femoral stem. Results In a cohort of 5,264 hips, Kaplan-Meier survivorship estimates (95% confidence interval [CI]; N with further follow-up), with survivorship defined as no revision of any component for any reason at five years after the index procedure, were 98.9% (97.8%-99.4%; 43) under the clinical assumption and 99.6% (99.4%-99.7%; 894) under the registry assumption. With survivorship defined as stem revision for any reason, survivorship estimates at five years postoperatively were 99.6% (99.3%-99.8%; 43) under the clinical assumption and 99.8% (99.7%-99.9%; 894) under the registry assumption. The mean follow-up time was 94.52 days (standard deviation [SD] 2.24, range 90.03-96.02). At five years postoperatively, the mean Harris Hip Score was 95.19, and the mean Hip Disability and Osteoarthritis Outcome Score Junior (HOOS JR) score was 98.66. Conclusions Our evaluation demonstrates excellent construct and stem survivorship and very low complication rates at midterm postoperative follow-up.
Collapse
Affiliation(s)
| | | | | | | | - Sean Croker
- Clinical Research, DePuy Synthes, Warsaw, USA
| | - Robert Gorab
- Orthopedic Surgery, Hoag Orthopedics Institute, Irvine, USA
| |
Collapse
|
4
|
Rolvien T, Thiessen ML, Boese CK, Bechler U, Strahl A, Beil FT, Ries C. Areal bone mineral density is not associated with femoral stem subsidence in patients younger than 70 years undergoing total hip arthroplasty. Arch Orthop Trauma Surg 2024; 144:1415-1422. [PMID: 38062273 PMCID: PMC10896811 DOI: 10.1007/s00402-023-05137-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 11/11/2023] [Indexed: 02/28/2024]
Abstract
INTRODUCTION Femoral stem subsidence is a known complication after uncemented total hip arthroplasty (THA). The purpose of this study was to determine the frequency of osteoporosis and to investigate the relationship between areal bone mineral density (aBMD) and subsidence in a cohort of patients younger than 70 years. METHODS One hundred consecutive patients (age 60 ± 6 years; 52 female, 48 male) undergoing uncemented THA using a collarless press fit femoral stem were retrospectively reviewed. Dual-energy X-ray absorptiometry (DXA) was performed preoperatively at the proximal femur and lumbar spine, and if not feasible at these sites, at the distal radius. DXA results were compared to a cohort of 100 patients ≥ 70 years scheduled for cemented THA. Age, sex, and body mass index (BMI), canal flare index (CFI), and canal fill ratio (CFR) were assessed. Analysis of stem subsidence and migration was performed on standardized, calibrated radiographs obtained postoperatively and at follow-up. RESULTS The frequency of osteoporosis was considerably lower in the study cohort compared to patients ≥ 70 years (7% vs. 19%, p = 0.02). Illustrated by the high CFR (mean 96 ± 4%) in the mid-stem region, a sufficient press fit was achieved. After a mean follow-up of 7.4 months, the mean stem subsidence was 0.9 ± 0.9 mm. Only two patients had subsidence greater than 3 mm, one of whom was morbidly obese and the other diagnosed with severe osteoporosis. There were no correlations between any of the parameters (CFI, CFR, age, sex, BMI) and femoral stem subsidence. In addition, aBMD T-scores showed no correlations with subsidence. CONCLUSION aBMD by DXA does not appear to be associated with stem subsidence in patients younger than 70 years and with adequate press fit.
Collapse
Affiliation(s)
- Tim Rolvien
- Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.
| | - Maximilian Lenard Thiessen
- Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Christoph Kolja Boese
- Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Ulrich Bechler
- Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - André Strahl
- Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Frank Timo Beil
- Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Christian Ries
- Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.
| |
Collapse
|
5
|
Saldivar RM, Buller LT, Deckard ER, Sonn KA, Meneghini RM. Durability of Primary Total Hip Arthroplasty With Cementless Stems Without a Collar in Elderly Patients Age 75 Years and Over. J Arthroplasty 2024:S0883-5403(24)00177-3. [PMID: 38408715 DOI: 10.1016/j.arth.2024.02.058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 02/14/2024] [Accepted: 02/19/2024] [Indexed: 02/28/2024] Open
Abstract
BACKGROUND Cementless femoral fixation in total hip arthroplasty (THA) has increased in prevalence worldwide. However, cementless fixation in elderly patients is controversial due to the risks of periprosthetic fracture and aseptic loosening. This study evaluated outcomes in patients undergoing primary THA utilizing a cementless stem without a collar, comparing those less than 75 years to those older than 75 years. METHODS Between 2011 and 2021, there were 2,605 cementless THAs performed by 4 surgeons utilizing a highly porous metal fixation surface without a collar and consistent clinical protocols. There were 469 patients who had an age ≥ 75 years. Revision rates, intraoperative fractures, and 90-day mortality were compared between cohorts. In the ≥ 75 year age group, there were more women, more American Society of Anesthesiologists physical status classification III or IV, a lower body mass index, and more kidney disease, osteoporosis, and thyroid disease (P ≤ .002). RESULTS All-cause revision rates trended lower for the ≥75 year age group compared to < 75 year (1.9 versus 3.5%, P = .082) at 20-months of follow-up. Moreover, there was no difference in all-cause femoral component revisions comparing ≥ 75 to < 75 year age groups (1.5 versus 2.2%, P = .375), with only 3 of 10 femoral revisions due to aseptic loosening being in the ≥ 75 year age group. Intraoperative fracture (0.2 versus 0.5%, P = .701) and 90-day mortality (0.2 versus 0.1%, P = .460) did not differ between ≥ 75 and < 75 year age groups. CONCLUSIONS Older patients had comparable revision rates compared to younger patients using cementless femoral fixation without a collar. Furthermore, there was no difference in 90-day mortality or intraoperative fracture rates. Study findings provide evidence for the safety and durability of cementless THA using collarless femoral stems in elderly patients ≥ 75 years of age. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Robert M Saldivar
- Surgery Residency, Medical University of South Carolina, Charleston, South Carolina
| | - Leonard T Buller
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana
| | - Evan R Deckard
- Indiana Joint Replacement Institute, Indianapolis, Indiana
| | - Kevin A Sonn
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana
| | - R Michael Meneghini
- Department of Orthopaedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana; Indiana Joint Replacement Institute, Indianapolis, Indiana
| |
Collapse
|
6
|
Huang Z, Zhang Z, Wang W, Wang G, Lu X, Zhang H. Improved radiographic outcomes and decreased complications rate on the femoral side can be achieved by a novel designed whole-process robotic assisted hip system for total hip arthroplasty: a prospective randomized controlled trial. J Robot Surg 2024; 18:79. [PMID: 38365906 DOI: 10.1007/s11701-024-01835-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Accepted: 01/14/2024] [Indexed: 02/18/2024]
Abstract
Postoperative complications due to inaccurate prosthesis positioning are the main causes of early revision. The aim of this study was to (1) determine whether novel designed whole-process robotic assisted hip system allowed better radiographic outcomes and lower complications risk on the femoral side particularly stem subsidence compared to conventional THA, and to (2) identify the comparison of early clinical outcomes. 72 patients were initially enrolled and randomly divided into 2 groups. Finally, only 65 patients (31 RA-THAs, 34 C-THAs) were analyzed who had full 18-month follow-up data. Radiographic follow-up was performed at immediate and 6-month postoperatively, while clinical follow-up at 18-month postoperatively. Stem-related radiographic outcomes, femoral side complications and clinical scores were compared. The robotic arm allowed better radiographic outcomes of the femoral side, including a higher canal fill ratio (CFR) at B1 (P = 0.040), more neutral stem alignment (P = 0.029), lower subsidence (P = 0.023) and lower leg length discrepancy (LLD) (P = 0.010). In addition, low CFR at B1 (P = 0.001) was found the risk factor for subsidence. However, early clinical outcomes were consistent between both groups. The novel designed whole-process robotic assisted hip system covers both femoral and acetabular side operations. It allows accurate and safe manipulation of femoral side, including better stem-related radiographic outcomes and lower risk of subsidence and LLD. However, no advantage of robotic system in early clinical score was identified. Clinical trial registration number: ChiCTR2100044124.
Collapse
Affiliation(s)
- Zhenchao Huang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, Shandong, China
| | - Zian Zhang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, Shandong, China
| | - Wenzhe Wang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, Shandong, China
| | - Guanrong Wang
- Nursing Department of Operating Room, The Affiliated Hospital of Qingdao University, Qingdao, Shandong, China
| | - Xinzhe Lu
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, Shandong, China
| | - Haining Zhang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, 266000, Shandong, China.
| |
Collapse
|
7
|
Leiss F, Goetz JS, Schindler M, Reinhard J, Müller K, Grifka J, Greimel F, Meyer M. Influence of bone mineral density on femoral stem subsidence after cementless THA. Arch Orthop Trauma Surg 2024; 144:451-458. [PMID: 37578658 DOI: 10.1007/s00402-023-05006-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 07/22/2023] [Indexed: 08/15/2023]
Abstract
INTRODUCTION Femoral stem subsidence can lead to aseptic loosening after total hip arthroplasty (THA). Low bone mineral density (BMD) is a risk factor for stem subsidence as it can affect the initial stability and osteointegration. We evaluated whether reduced bone mineral density is related to higher subsidence of the femoral stem after primary cementless THA with enhanced recovery rehabilitation. METHODS 79 patients who had undergone primary cementless THA with enhanced recovery rehabilitation were analyzed retrospectively. Subsidence of the femoral stem was measured on standing pelvic anterior-posterior radiographs after 4-6 weeks and one year. Patient individual risk factors for stem subsidence (stem size, canal flare index, canal fill ratio, body mass index (BMI), demographic data) were correlated. Dual X-ray absorptiometry (DXA) scans were performed of the formal neck and the lumbar spine including the calculation of T-score and Z-score. Patient-reported outcome measures were evaluated 12 months postoperatively. RESULTS Stem subsidence appeared regardless of BMD (overall collective 2.3 ± 1.64 mm). Measure of subsidence was even higher in patients with normal BMD (2.8 ± 1.7 mm vs. 2.0 ± 1.5 mm, p = 0.05). High BMI was correlated with increased stem subsidence (p = 0.015). Subsidence had no impact on improvement of patient-related outcome measures (WOMAC, EQ-5D-5L and EQ-VAS) after THA. Patients with low BMD reported lower quality of life 12 month postoperatively compared to patients with normal BMD (EQ-5D-5L 0.82 vs. 0.91, p = 0.03). CONCLUSION Stable fixation of a cementless stem succeeds also in patients with reduced BMD. Regarding stem subsidence, enhanced recovery rehabilitation can be safely applied in patients with low BMD.
Collapse
Affiliation(s)
- Franziska Leiss
- Department of Orthopedic Surgery, Asklepios Klinikum Bad Abbach, Regensburg University Medical Center, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany.
| | - Julia Sabrina Goetz
- Department of Orthopedic Surgery, Asklepios Klinikum Bad Abbach, Regensburg University Medical Center, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Melanie Schindler
- Department of Orthopedic Surgery, Asklepios Klinikum Bad Abbach, Regensburg University Medical Center, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Jan Reinhard
- Department of Orthopedic Surgery, Asklepios Klinikum Bad Abbach, Regensburg University Medical Center, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Karolina Müller
- Center for Clinical Studies, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053, Regensburg, Germany
| | - Joachim Grifka
- Department of Orthopedic Surgery, Asklepios Klinikum Bad Abbach, Regensburg University Medical Center, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Felix Greimel
- Department of Orthopedic Surgery, Asklepios Klinikum Bad Abbach, Regensburg University Medical Center, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| | - Matthias Meyer
- Department of Orthopedic Surgery, Asklepios Klinikum Bad Abbach, Regensburg University Medical Center, Kaiser-Karl V.-Allee 3, 93077, Bad Abbach, Germany
| |
Collapse
|
8
|
Thalody HS, Post ZD, Bridges TN, Qadiri QS, Scaramella A, Ong AC, Ponzio DY. Does Automated Impaction Improve Femoral Component Sizing and Alignment in Total Hip Arthroplasty? J Arthroplasty 2023; 38:2154-2158. [PMID: 37146701 DOI: 10.1016/j.arth.2023.04.054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 04/22/2023] [Accepted: 04/25/2023] [Indexed: 05/07/2023] Open
Abstract
BACKGROUND While automated impaction can provide a more standardized process for femoral canal preparation, little is known regarding its effect on femoral component sizing and position. The purpose of our study was to directly compare femoral component canal fill ratio (CFR) and coronal alignment between primary total hip arthroplasty (THA) procedures performed with automated impaction versus manual mallet impaction. METHODS A retrospective analysis was performed on 184 patients who underwent primary THA by a single arthroplasty surgeon between 2017 and 2021 with a modern cementless femoral component using either the direct anterior or posterolateral approach. The final cohort was divided into 2 groups based on impaction technique during broaching: automated (N = 122) or manual (N = 62). A propensity score match was used to match for age, body mass index, sex, high versus standard offset stem, and preoperative femoral bone quality. Radiographic review was performed to measure intramedullary prosthetic CFR and coronal alignment. RESULTS The automated cohort trended toward the use of a larger stem (5.67 versus 4.82, P = .006) and had a larger CFR at all 4 levels within the proximal femur (P = .004). The automated cohort had a more valgus and reliable coronal alignment (-0.57 (SD 1.50) versus -0.03 (SD 2.17) degrees, P = .03) and significantly shorter operative time (mean 78 versus 90 minutes, P < .001). There were no intraoperative or postoperative periprosthetic fractures in either cohort. CONCLUSION Automated impaction in primary THA is a safe technique for femoral preparation, which resulted in improved stem coronal alignment, optimized canal fill within the proximal femur, and reduced operative times.
Collapse
Affiliation(s)
| | - Zachary D Post
- Rothman Orthopaedic Institute, Egg Harbor Township, New Jersey
| | | | | | | | - Alvin C Ong
- Rothman Orthopaedic Institute, Egg Harbor Township, New Jersey
| | | |
Collapse
|
9
|
Single Wedge Femoral Stem Designs are Associated With a Higher Risk for Revision After Cementless Primary Total Hip Arthroplasty. J Arthroplasty 2022; 38:855-861.e1. [PMID: 36535447 DOI: 10.1016/j.arth.2022.12.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 11/30/2022] [Accepted: 12/12/2022] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Cementless total hip arthroplasty (THA) femoral stems are the most commonly selected prostheses in the United States. Optimal stem geometry remains controversial with excellent survivorship reported for many designs. We compared cause-specific stem revision of single-wedge versus double-wedge designs from a multicenter US cohort. METHODS Data from an integrated healthcare network's total joint replacement registry were used to conduct a cohort study. Primary elective cementless THAs were identified (2001 to 2018). Implant exposure groups were classified by design geometry using the system proposed by Khanuja et al. Type 1 single-wedge (n = 11,082) and type 2 double-wedge (n = 32,380) designs were compared, and other design types were excluded; the final study cohort comprised 43,462 THAs. Cause-specific multivariable Cox regressions were used to evaluate risk for revision due to infection or aseptic reasons, including loosening, instability, periprosthetic fracture, or other reasons. RESULTS After adjustment for covariates, a higher aseptic revision risk was observed for type 1 when compared to type 2 designs (hazard ratio = 1.91, 95% confidence interval = 1.33-2.75). When looking at specific revision reasons, revision for aseptic loosening (hazard ratio = 3.46, 95% confidence interval = 2.24-5.34) was higher for type 1 versus type 2 designs. No differences were found for septic revision, instability, periprosthetic fracture, or revisions for other reasons. CONCLUSIONS Type 1 single-wedge designs were found to have a higher risk of revision due to aseptic loosening relative to type 2 double-wedge designs. Femoral stem geometry should be considered when selecting a cementless femoral implant. LEVEL OF EVIDENCE Level III.
Collapse
|
10
|
Alpaugh K, Chiu YF, Zlotnicki JP, Bendich I, Valle AGD, Bostrom MPG, Gausden EB. Femoral Component Undersizing and Alignment are Risk Factors for Early Periprosthetic Femur Fracture. J Arthroplasty 2022; 37:S604-S610. [PMID: 35283234 DOI: 10.1016/j.arth.2022.03.015] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 02/26/2022] [Accepted: 03/03/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Known risk factors for early periprosthetic femur fracture (PFF) following total hip arthroplasty (THA) include poor bone quality and the use of cementless implants. The association between femoral component size and alignment and the risk of early PFF is not well described. We evaluated radiographic parameters of femoral component sizing and alignment as risk factors for early PFF. METHODS From 16,065 primary cementless THAs, we identified 66 cases (0.41%) of early PFFs (<90 days from index THA) at a single institution between 2016 and 2020. Sixty early PFFs were (1:2) matched to 120 controls based on the femoral component model, offset, surgical approach, age, body mass index (BMI), and gender. Radiographic assessment of preoperative bone morphology and postoperative femoral component orientation included stem alignment, metaphyseal fill, and implant congruence with medial cortical bone. A multivariable logistic regression was built to identify radiographic risk factors associated with early PFF. RESULTS Markers of preoperative bone quality including canal calcar ratio (P = .003), canal flare index (P < .001), anteroposterior canal bone ratio (CBR) (P < .001), and lateral CBR (P < .001) were statistically associated with PFF. Distance between the medial cortical bone and implant was greater in cases of PFF (2.5 mm vs 1.4 mm) (P < .001). A multivariate analysis demonstrated that a larger lateral metaphyseal CBR (Odds Ratio [OR] 5), valgus implant alignment (OR 5), and medial implant-bone incongruity (OR 2) increased the risk of early PFF. CONCLUSION A larger lateral metaphyseal CBR, valgus component alignment, and implant incongruity with medial cortical bone posed the greatest radiographic risk for early PFF following cementless THA.
Collapse
Affiliation(s)
- Kyle Alpaugh
- Adult Reconstruction & Joint Replacement, Hospital for Special Surgery, New York, New York; Department of Orthopaedic Surgery, Arthroplasty Division, Massachusetts General Hospital, Boston, Massachusetts
| | - Yu-Fen Chiu
- Adult Reconstruction & Joint Replacement, Hospital for Special Surgery, New York, New York
| | - Jason P Zlotnicki
- Adult Reconstruction & Joint Replacement, Hospital for Special Surgery, New York, New York
| | - Ilya Bendich
- Adult Reconstruction & Joint Replacement, Hospital for Special Surgery, New York, New York
| | | | - Mathias P G Bostrom
- Adult Reconstruction & Joint Replacement, Hospital for Special Surgery, New York, New York
| | - Elizabeth B Gausden
- Adult Reconstruction & Joint Replacement, Hospital for Special Surgery, New York, New York
| |
Collapse
|
11
|
Suksathien Y, Chuvanichanon P, Tippimanchai T, Sueajui J. Insufficient lateral stem contact is an influencing factor for significant subsidence in cementless short stem total hip arthroplasty. World J Orthop 2022; 13:444-453. [PMID: 35633743 PMCID: PMC9124996 DOI: 10.5312/wjo.v13.i5.444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 01/25/2022] [Accepted: 04/28/2022] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Subsidence is one of the concerning early complications in cementless femoral stem. Few publications have studied the influencing factors for subsidence in short cementless stems, due to their metaphyseal anchoring without diaphyseal invasion, they might demonstrate different subsidence patterns than with the conventional stems.
AIM To analyze the factors associated with significant subsidence in short stems, including any radiographic parameters.
METHODS The digitized radiographs of 274 consecutive short stem total hip arthroplasties were retrospectively reviewed. Subsidence, neck-filling ratio (NFR), seating height and lateral stem contact were evaluated after a minimum of two years follow-up. A threshold of subsidence > 3 mm was considered a clinically significant migration.
RESULTS For the entire cohort, subsidence occurred in 75 cases (27.4%) with the mean stem subsidence of 0.5 mm. (0-12.7, 1.68). Twelve hips (4.4%) had significant subsidence (> 3 mm). The univariate regression analysis demonstrated that age, diagnosis, BMI, Dorr’s type B, NFR, and seating height had no significant influence on significant subsidence, whereas insufficient lateral stem contact (≥ 1 mm) did have a statistically significant influence [Odds ratio (OR) = 5.02; 95%CI: 1.3-18.9; P = 0.017]. The multivariate regression analysis also demonstrated that insufficient lateral stem contact was a statistically significant influencing factor (OR = 5.5; 95%CI: 1.4-21.4; P = 0.014). There was no femoral stem revision for aseptic loosening in our cohort.
CONCLUSION This study demonstrated that insufficient lateral stem contact was a statistically significant influencing factor on significant subsidence. Therefore, it is a particularly important step to create proper lateral cortical contact when performing the short stem total hip arthroplasty.
Collapse
Affiliation(s)
- Yingyong Suksathien
- Department of Orthopedic Surgery, Maharat Nakhon Ratchasima Hospital, Muang 30000, Nakhon Ratchasima Province, Thailand
| | - Pattawat Chuvanichanon
- Department of Orthopedic Surgery, Maharat Nakhon Ratchasima Hospital, Muang 30000, Nakhon Ratchasima Province, Thailand
| | - Thanut Tippimanchai
- Department of Orthopedic Surgery, Maharat Nakhon Ratchasima Hospital, Muang 30000, Nakhon Ratchasima Province, Thailand
| | - Jithayut Sueajui
- Department of Orthopedic Surgery, Maharat Nakhon Ratchasima Hospital, Muang 30000, Nakhon Ratchasima Province, Thailand
| |
Collapse
|
12
|
Gazendam A, Ekhtiari S, Wood TJ. Intermediate to Long-Term Outcomes and Causes of Aseptic Failure of an At-Risk Femoral Stem. J Bone Joint Surg Am 2022; 104:896-901. [PMID: 35188899 DOI: 10.2106/jbjs.21.00397] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The Accolade TMZF is a tapered-wedge cementless metaphyseal-coated femoral stem that was widely utilized from 2002 to 2012. In recent years, there have been reports of early catastrophic failure of this implant. The purposes of the present study were to establish the long-term survival of this stem and to analyze patients who underwent aseptic revision to understand the causes and risk factors for failure. METHODS We retrospectively reviewed the records of all patients who had undergone primary total hip arthroplasty with use of an Accolade TMZF stem at a high-volume arthroplasty center. The causes and timing of revision surgery were documented. Survivorship analysis was performed with use of Kaplan-Meier curves to determine the overall and aseptic survival rates at the time of the latest follow-up. Patient and implant factors commonly associated with aseptic failure were extracted, and a Cox proportional hazards model was used. RESULTS A consecutive series of 2,609 patients who had undergone unilateral primary total hip arthroplasty with use of an Accolade TMZF femoral stem were included. The mean time from the primary procedure was 11.3 years (range, 0 days to 19.4 years). The cumulative survival rate was 95.5% ± 0.1% at the time of the latest follow-up. One hundred and seven patients underwent revision surgery, with aseptic loosening of the femoral component being the most common cause of aseptic failure in this cohort (33 of 2,609; 1.3%). Smaller femoral size and larger femoral head offset were independent risk factors for aseptic failure. CONCLUSIONS To our knowledge, this is the largest series representing the longest follow-up of this tapered-wedge cementless femoral implant. Despite early concerns, the Accolade TMZF stem had excellent survivorship in this cohort. Trunnionosis as the cause for revision surgery was rare. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Aaron Gazendam
- Division of Orthopaedics, Department of Surgery, McMaster University, Hamilton, Ontario, Canada
| | - Seper Ekhtiari
- Division of Orthopaedics, Department of Surgery, McMaster University, Hamilton, Ontario, Canada
| | - Thomas J Wood
- Division of Orthopaedics, Department of Surgery, McMaster University, Hamilton, Ontario, Canada.,Juravinski Hospital, Hamilton Health Sciences, Hamilton, Ontario, Canada
| | | |
Collapse
|
13
|
Acoustic characteristics of broaching procedure for post-operative stem subsidence in cementless total hip arthroplasty. INTERNATIONAL ORTHOPAEDICS 2022; 46:741-748. [PMID: 34977970 DOI: 10.1007/s00264-021-05278-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2021] [Accepted: 11/26/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE Avoiding stem subsidence is crucial for achieving better outcome for cementless total hip arthroplasty (THA). The aim of this study was to develop a prediction model for the incidence of post-operative stem subsidence using full quantitative acoustic parameters in hammering sound during the broaching procedure and to assess the accuracy of this prediction model. METHODS The acoustic parameters of the hammering sounds during a broaching procedure for 55 hips in 49 patients who underwent THAs with cementless taper-wedged stem were analysed. The stem subsidence was assessed at one month post-operatively, and the relationship between the acoustic parameters and the value of stem subsidence was investigated. RESULTS The average stem subsidence was 2.15 ± 2.91 mm. The subsidence 3 mm or more was observed in eleven hips (20%), and 5 mm or more was observed in seven hips (12.7%). Basic patient's characteristics, preoperative femoral morphology and immediate post-operative canal fill ratio and stem alignment were not significantly related to the volume of stem subsidence. Nine acoustic parameters were significantly correlated with the value of subsidence. The prediction model for post-operative subsidence using only acoustic parameters during broaching procedure was established, and this model showed a positive prediction value of 100% and a negative prediction value of 90.6% for post-operative stem subsidence at 5 mm or more. CONCLUSION Post-operative stem subsidence can be predicted by using acoustic parameters of the hammering sound during the broaching procedure. Our results suggest that we are at the start of a new era in which novel and innovative smart technologies can be used to assist in orthopaedic surgery.
Collapse
|
14
|
Finnilä S, Löyttyniemi E, Aro HT. Denosumab in Cementless Total Hip Arthroplasty: Multivariate Reanalysis of
3D
Femoral Stem Migration and the Influence on Outliers. JBMR Plus 2021; 6:e10588. [PMID: 35229065 PMCID: PMC8861983 DOI: 10.1002/jbm4.10588] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 11/10/2021] [Accepted: 11/22/2021] [Indexed: 11/13/2022] Open
Abstract
In cementless total hip arthroplasty, adequate implant stability is necessary for the success of osseointegration and rapid clinical recovery. Postoperative femoral stem migration, measured by radiostereometric analysis (RSA), defines the initial stability achieved during surgical implantation. In a recent trial of 65 postmenopausal women randomized 1:1 denosumab:placebo, denosumab failed to reduce the initial migration of a cementless femoral stem despite the successful prevention of periprosthetic bone loss. The trial applied the current RSA standard, which examined stem migration on an axis‐by‐axis basis and did not consider more complex three‐dimensional (3D) migration. Therefore, we performed a reanalysis of the trial data using a multivariate hierarchical linear mixed model (LMM). As an additional limitation, the data included influential outliers. Women with normal bone mineral density exhibited significantly (p = 0.036) less stem subsidence compared with osteopenic and osteoporotic women. Denosumab significantly decreased the variance of stem migration in osteopenic and osteoporotic women. The mean magnitude of 3D stem migration did not differ between denosumab‐treated and placebo‐treated women (p = 0.820). After application of a common statistical definition for RSA outlier identification, there were eight (12%) outliers, six in the placebo group and two in the denosumab group (p = 0.149). After exclusion of the outliers, the repeated LMM analysis demonstrated a trending difference in 3D stem migration (p = 0.086), with a significant difference of z‐axis rotation (valgus‐varus tilt) of the femoral stem (p = 0.029). The observed effect size was small and without clinically important differences in postoperative recovery. Based on a Monte Carlo simulation with random‐generated 3D migration data, multivariate LMM showed greater statistical power than univariate analyses. The application of hierarchical LMM facilitated the analysis of implant migration as a factual 3D event. The observed trend in the lower number of RSA outliers in denosumab‐treated subjects warrants powered large‐scale trials. © 2021 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Sami Finnilä
- Department of Orthopaedic Surgery and Traumatology Turku University Hospital and University of Turku Turku Finland
| | - Eliisa Löyttyniemi
- Unit of Biostatistics, Department of Clinical Medicine University of Turku Turku Finland
| | - Hannu T Aro
- Department of Orthopaedic Surgery and Traumatology Turku University Hospital and University of Turku Turku Finland
| |
Collapse
|
15
|
Tan N, van Arkel RJ. Topology Optimisation for Compliant Hip Implant Design and Reduced Strain Shielding. MATERIALS (BASEL, SWITZERLAND) 2021; 14:7184. [PMID: 34885337 PMCID: PMC8658148 DOI: 10.3390/ma14237184] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 11/01/2021] [Accepted: 11/22/2021] [Indexed: 01/12/2023]
Abstract
Stiff total hip arthroplasty implants can lead to strain shielding, bone loss and complex revision surgery. The aim of this study was to develop topology optimisation techniques for more compliant hip implant design. The Solid Isotropic Material with Penalisation (SIMP) method was adapted, and two hip stems were designed and additive manufactured: (1) a stem based on a stochastic porous structure, and (2) a selectively hollowed approach. Finite element analyses and experimental measurements were conducted to measure stem stiffness and predict the reduction in stress shielding. The selectively hollowed implant increased peri-implanted femur surface strains by up to 25 percentage points compared to a solid implant without compromising predicted strength. Despite the stark differences in design, the experimentally measured stiffness results were near identical for the two optimised stems, with 39% and 40% reductions in the equivalent stiffness for the porous and selectively hollowed implants, respectively, compared to the solid implant. The selectively hollowed implant's internal structure had a striking resemblance to the trabecular bone structures found in the femur, hinting at intrinsic congruency between nature's design process and topology optimisation. The developed topology optimisation process enables compliant hip implant design for more natural load transfer, reduced strain shielding and improved implant survivorship.
Collapse
Affiliation(s)
| | - Richard J. van Arkel
- Department of Mechanical Engineering, Imperial College London, London SW7 2AZ, UK;
| |
Collapse
|
16
|
Aro HT. Bone quality makes a difference. Acta Orthop 2021; 92:503-504. [PMID: 34180754 PMCID: PMC8522809 DOI: 10.1080/17453674.2021.1941632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Affiliation(s)
- Hannu T. Aro
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland,Hannu T. Aro Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| |
Collapse
|
17
|
Fujii M, Kitamura K, Ikemura S, Hamai S, Motomura G, Nakashima Y. Pneumatic femoral broaching decreases post-operative subsidence of a cementless taper-wedge stem. INTERNATIONAL ORTHOPAEDICS 2021; 46:233-240. [PMID: 34448924 DOI: 10.1007/s00264-021-05196-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Accepted: 08/15/2021] [Indexed: 11/30/2022]
Abstract
PURPOSE Stem subsidence is a known cause of early failure in cementless total hip arthroplasty (THA). The aim of this study was to determine the usefulness of pneumatic femoral broaching in preventing post-operative subsidence of a proximally porous-coated, taper-wedge stem. METHODS We reviewed 169 cases of primary THA with a single taper-wedge stem. Eighty THAs performed using pneumatic broaching were compared with 89 THAs performed using manual broaching in terms of postoperative canal fill ratio (CFR) at three levels, stem subsidence at one year post-operation, and stem fixation at latest follow-up (median, 24 months). RESULTS The median CFRs were higher in the pneumatic group than in the manual group at all levels (p < 0.05). The median stem subsidence at one year after THA was lower in the pneumatic group than in the manual group (0.2 mm vs. 0.6 mm, p = 0.007). A multivariate analysis determined a decreased CFR at 60 mm below the lesser trochanter and the manual broaching as independent factors affecting post-operative stem subsidence. At the latest follow-up, all stems showed stable fixation by bone ingrowth in both groups. CONCLUSION Our results showed that the pneumatic broaching device was useful in maximizing the mediolateral canal filling and initial stability and minimizing the subsidence of taper-wedge stems.
Collapse
Affiliation(s)
- Masanori Fujii
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi. Higashi-ku, Fukuoka, 812-8582, Japan.
| | - Kenji Kitamura
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi. Higashi-ku, Fukuoka, 812-8582, Japan
| | - Satoshi Ikemura
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi. Higashi-ku, Fukuoka, 812-8582, Japan
| | - Satoshi Hamai
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi. Higashi-ku, Fukuoka, 812-8582, Japan
| | - Goro Motomura
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi. Higashi-ku, Fukuoka, 812-8582, Japan
| | - Yasuharu Nakashima
- Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi. Higashi-ku, Fukuoka, 812-8582, Japan
| |
Collapse
|
18
|
Aro HT, Engelke K, Mattila K, Löyttyniemi E. Volumetric Bone Mineral Density in Cementless Total Hip Arthroplasty in Postmenopausal Women: Effects on Primary Femoral Stem Stability and Clinical Recovery. J Bone Joint Surg Am 2021; 103:1072-1082. [PMID: 33750747 DOI: 10.2106/jbjs.20.01614] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND In cementless total hip arthroplasty, femoral stems should preferably not migrate at all postoperatively. This goal is difficult to achieve in postmenopausal women with impaired bone quality. Here, we explored the clinical importance of initial stem migration, measured by radiostereometric analysis (RSA), in women who underwent quantitative computed tomography (CT) of the involved hip preoperatively. METHODS A prospective cohort of 65 postmenopausal women (mean age, 69 years) with hip osteoarthritis and Dorr type-A or B femoral anatomy underwent total hip arthroplasty with implantation of a tapered, single-wedge femoral stem. Volumetric bone mineral density (BMD) was measured using quantitative CT. Femoral stem translation and rotation were measured using model-based RSA within 3 days after the surgical procedure and were repeated at 3, 5, and 11 months. Postoperative recovery parameters included walking speed, walking activity, and patient-reported outcome measures. Subjects were categorized into 2 groups according to the magnitude of initial 5-month stem subsidence (<2 mm or ≥2 mm); RSA outliers (n = 7) were analyzed separately. RESULTS Subjects with stem subsidence of ≥2 mm (mean, 3.09 mm [95% confidence interval (CI), 2.70 to 3.47 mm]) had lower intertrochanteric volumetric BMD (p = 0.008). Subjects with subsidence of <2 mm (mean, 0.80 mm [95% CI, 0.51 to 1.09 mm]) had faster improvement of patient-reported outcome measures and exhibited faster walking speed (p = 0.007) and greater walking activity (p = 0.010) at 11 months as well as better Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores (p = 0.002) and RAND 36-Item Health Survey mental component scores (p = 0.006) at 2 years. All cohort stems were osseointegrated at 2 years. CONCLUSIONS Femoral stem stability and resistance to subsidence were sensitive to adequate intertrochanteric volumetric BMD. Low intertrochanteric volumetric BMD was associated with greater stem migration. With initial migration, clinical recovery was slower and patient-reported outcome measures were less satisfactory. LEVEL OF EVIDENCE Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Hannu T Aro
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| | - Klaus Engelke
- Institute of Medical Physics, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Kimmo Mattila
- Department of Diagnostic Imaging, Turku University Hospital and University of Turku, Turku, Finland
| | - Eliisa Löyttyniemi
- Unit of Biostatistics, Department of Clinical Medicine, University of Turku, Turku, Finland
| |
Collapse
|
19
|
Atrey A, Khoshbin A, Rolfson O, Campbell D, Wood G, Bohm E, Jones C, Kandel C, Davis J, Atri N, Abdelbary H, Moojen DJ, Dunbar M, Manning L, Paxton EW, Yates P, Waddell JP, Ravi B, Reed M. Infection: The Final Frontier of Arthroplasty Management: A Proposal for a Global Periprosthetic Joint Infection Registry from a Multinational Collaborative Group, the GAIA (Global Arthroplasty Infection Association). J Bone Joint Surg Am 2021; 103:e22. [PMID: 33433125 DOI: 10.2106/jbjs.20.01517] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Amit Atrey
- University of Toronto, Toronto, Ontario, Canada
| | | | - Ola Rolfson
- University of Gothenburg, Gothenburg, Sweden
| | - David Campbell
- Wakefield Hospital, Adelaide, South Australia, Australia
| | - Gavin Wood
- University of Queens, Kingston, Ontario, Canada
| | - Eric Bohm
- University of Manitoba, Winnipeg, Manitoba, Canada
| | | | | | - Joshua Davis
- Menzies University, Darwin, Northern Territory, Australia
| | - Nipun Atri
- Rush University Medical Centre, Chicago, Illinois
| | | | - Dirk Jan Moojen
- Department of Orthopaedic Surgery, Joint Research OLVG, Amsterdam, the Netherlands
| | | | - Laurens Manning
- University of Western Australia, Perth, Western Australia, Australia
| | | | - Piers Yates
- University of Western Australia, Perth, Western Australia, Australia
| | | | | | - Mike Reed
- Bone and Joint Infection Registry (BAJIR), Northumbria, United Kingdom
| | | |
Collapse
|
20
|
Abstract
Aims We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years. Methods A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one. Results Two femoral components (3.2%) required revision. One stem was revised secondary to a periprosthetic fracture one year postoperatively and one was revised for late sepsis. No femoral component was revised for aseptic loosening. Six acetabular components had required revision, five for aseptic loosening. One additional acetabular component was revised for sepsis. Radiologically, all femoral components remained well fixed. One acetabular was judged loose by radiological criteria. The mean Harris Hip Score improved from 46 points (30 to 67) preoperatively to 89 points (78 to 100) at final follow-up. With revision for aseptic loosening as the endpoint, survival of the acetabular component was 95% (95% confidence interval (CI) 90 to 98) at 25 years. Femoral component survival was 100%. Conclusion The most significant finding of this report was the low prevalence of aseptic loosening and revision of the femoral component at a mean follow-up of 22 years. A second important finding was the survival of over 90% of the hemispheric threaded ring acetabular components. While these shells remain controversial, in this series they performed well.Cite this article: Bone Jt Open 2021;2(1):33-39.
Collapse
Affiliation(s)
| | - Kyla R Lee
- Gundersen Health, Crosse, Wisconsin, USA
| | | |
Collapse
|
21
|
Nazari-Farsani S, Vuopio M, Löyttyniemi E, Aro HT. Contributing factors to the initial femoral stem migration in cementless total hip arthroplasty of postmenopausal women. J Biomech 2021; 117:110262. [PMID: 33508723 DOI: 10.1016/j.jbiomech.2021.110262] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Revised: 01/01/2021] [Accepted: 01/10/2021] [Indexed: 02/06/2023]
Abstract
In cementless total hip arthroplasty (THA), femoral stems rely on the initial press-fit fixation against cortical bone to achieve osseointegration. Decreased bone mineral density (BMD) in postmenopausal women poses natural difficulties in achieving axial and rotational femoral stem stability. The present study examined contributing demographic, surgery-related and postoperative factors in determining the magnitude of early stem migration prior to osseointegration. A prospective cohort of 65 postmenopausal women with hip osteoarthritis (Dorr type A or B femur anatomy) underwent THA with implantation of an uncemented parallel-sided femoral component. Postoperative femoral stem translation and rotation were measured using model-based radiostereometric analysis. Based on analysis of covariance, which controlled for outliers and randomized antiresorptive treatment with denosumab or placebo, none of the analyzed demographics (including BMI) and surgery-related variables (including the stem-to-canal fil ratio) was associated with stem subsidence. Stem subsidence (mean 1.8 mm, 95% CI 1.2 to 2.4) occurred even in women with normal hip BMD. Total hip BMD and postoperative walking activity (measured three months after surgery) were significantly associated with stem rotation, and height acted as a confounding factor. The effect of walking activity on stem rotation was significant at 5 months (p = 0.0083) and at 11 months (p = 0.0117). This observation confirms the previous results of instrumented hip prostheses on torsional moments affecting stems during daily activities. High-resolution imaging modalities of local bone quality are needed to explore reasons for RSA-measurable stem subsidence even in women with normal hip BMD.
Collapse
Affiliation(s)
- Sanaz Nazari-Farsani
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| | - Mia Vuopio
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland
| | - Eliisa Löyttyniemi
- Unit of Biostatistics, Department of Clinical Medicine, University of Turku, Turku, Finland
| | - Hannu T Aro
- Department of Orthopaedic Surgery and Traumatology, Turku University Hospital and University of Turku, Turku, Finland.
| |
Collapse
|