1
|
van Basten Batenburg M, 't Mannetje YW, van Sambeek MRHM, Cuypers PWM, Georgiadis GS, Sondakh AO, Teijink JAW. Editor's Choice - Endurant Stent Graft in Patients with Challenging Neck Anatomy "One Step Outside Instructions for Use": Early and Midterm Results from the EAGLE Registry. Eur J Vasc Endovasc Surg 2022; 64:611-619. [PMID: 35987507 DOI: 10.1016/j.ejvs.2022.08.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 07/27/2022] [Accepted: 08/06/2022] [Indexed: 01/12/2023]
Abstract
OBJECTIVE The aim of the Endurant for Challenging Anatomy: Global Experience (EAGLE) registry is to evaluate prospectively the technical and clinical success rate of a stentgraft used in patients with challenging neck anatomy outside the instructions for use (IFU) but within objective anatomical limits. METHODS This was a prospective, international, multicentre, observational study. From 1 February 2012 to 1 September 2017, patients with an abdominal aortic aneurysm with a challenging infrarenal neck that were deemed suitable for endovascular aneurysm repair were included prospectively at 23 European centres. Patients were distributed by anatomy into three groups: short neck (SN; infrarenal neck 5 - 10 mm in combination with suprarenal angulation [α] ≤ 45° and infrarenal angulation [β] ≤ 60°); medium neck (MN; infrarenal neck 10 - 15 mm with α ≤ 60° and β 60° - 75° or α 45°- 60° and β ≤ 75°; and long angulated neck (LN; infrarenal neck ≥ 15 mm with α ≤ 75° and β 75°- 90° or α 60°- 75° and β ≤ 90°. All computed tomography scans were reviewed by an independent core laboratory. Primary outcomes were technical and clinical success. Secondary endpoints were peri-operative major adverse events, all cause mortality, aneurysm related mortality, endoleaks, migration, and secondary intervention. RESULTS One hundred and fifty patients (81.3% male) were included (SN = 55, MN = 16, LN = 79). The median follow up was 36 ± 12.6 months. In the overall cohort, the technical success rate was 93.3%. Estimated freedom from aneurysm related death was 97.3% at three years. Freedom from secondary interventions was 84.7% at three years. Estimated clinical success was 96.0%, 90.8%, and 83.2% at 30 days, one year, and three years, respectively. Estimated freedom from all cause mortality, late type IA endoleak, and migration at three years was 75.1%, 93.7%, and 99.3%, respectively. CONCLUSION The early and midterm results of the EAGLE registry show that endovascular repair with the Endurant stentgraft in selected patients with challenging infrarenal neck anatomy yields results in line with large "real world" registries. Long term results are awaited for more definitive conclusions.
Collapse
Affiliation(s)
- Michael van Basten Batenburg
- Department of Vascular Surgery, Catharina Hospital, Eindhoven, the Netherlands; Department of Epidemiology, CAPHRI Research School, Maastricht University, the Netherlands
| | - Yannick W 't Mannetje
- Department of Vascular Surgery, Catharina Hospital, Eindhoven, the Netherlands; Department of Epidemiology, CAPHRI Research School, Maastricht University, the Netherlands
| | - Marc R H M van Sambeek
- Department of Vascular Surgery, Catharina Hospital, Eindhoven, the Netherlands; Department of Cardiovascular Biomechanics, University of Technology Eindhoven, the Netherlands
| | | | - George S Georgiadis
- Department of Vascular Surgery, "Democritus" University of Thrace, University General Hospital of Alexandroupolis, Thrace, Greece
| | - Arthur O Sondakh
- Department of Vascular Surgery, Sint Jans Gasthuis, Weert, the Netherlands
| | - Joep A W Teijink
- Department of Vascular Surgery, Catharina Hospital, Eindhoven, the Netherlands; Department of Epidemiology, CAPHRI Research School, Maastricht University, the Netherlands.
| | | |
Collapse
|
2
|
Jensen R, Mathlouthi A, Al-Nouri O, Malas MB, Barleben A. "Aortic Balloon-Molding" (ABM) During Ovation Endograft Implantation Expands Graft Use for Hostile Neck Anatomy. Ann Vasc Surg 2022; 86:58-67. [PMID: 35803461 DOI: 10.1016/j.avsg.2022.05.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 05/09/2022] [Accepted: 05/27/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND Challenging aortoiliac anatomy such as short neck and narrow access vessels is responsible for EVAR ineligibility in up to 50% of cases. The Ovation stent-graft helped widen the range of AAAs suitable for EVAR thanks to its low-profile delivery system and polymer-filled sealing rings. However, its advantages are offset by a tight sizing chart that can lead to increased risk of type Ia endoleak or endograft infolding from under or oversizing, respectively. We sought to assess the safety and efficacy of a novel endovascular technique developed to expand the use of the Ovation endograft while avoiding these issues. METHODS We conducted a retrospective review of all patients who underwent EVAR with the Ovation endograft at our institution between March 2019 and December 2020. "Aortic Balloon Molding" or ABM is a novel endovascular technique in which the graft is pre-cannulated and a compliant aortic balloon is inflated at the site of the graft's sealing rings during polymer administration. The technique was preferentially performed in patients with hostile neck anatomy (HNA) defined as any or all of angulation>60°, reverse taper configuration, ≥50% circumferential thrombus or calcification. Patients undergoing traditional deployment were compared to those in whom ABM was performed. Endpoints included neck-related adjunctive procedures, technical success, type Ia endoleak at completion angiogram and 1-year freedom from type Ia endoleak and migration. RESULTS A total of 43 patients were included in the study, of which, 26 (60.5%) were treated with the ABM technique. Mean follow-up was 7.9±6 months. Patients in the ABM group were more likely to have a reverse taper neck (61.5% vs. 41.2%, P=0.1), to have significant circumferential thrombus or calcium (23.1% vs. 5.9%, P=0.1) and to be treated outside of the Ovation IFU regarding anatomic characteristics (65.4% vs. 41.2%, P=0.1). Technical success was achieved in 100% of cases. However, patients in the ABM group were less likely to require a neck-related adjunctive procedure (7.7% vs. 23.5%, P=0.1). Only one type Ia endoleak was observed at completion angiogram in a patient treated without ABM. At one-year, freedom from type Ia endoleak or migration was 100% for both groups. CONCLUSIONS Aortic Balloon Molding proves to be a safe and effective adjunctive technique for the treatment of AAAs with hostile neck anatomy using the Ovation stent-graft. This may allow optimal endograft sizing to achieve adequate seal in complex aortic anatomies. Further research is warranted to evaluate the long-term outcomes of this technique.
Collapse
Affiliation(s)
- Rachel Jensen
- Department of Surgery, Division of Vascular and Endovascular Surgery, University of California San Diego, 9444 Medical Center Drive, Number 3-22J, La Jolla, 92037 CA.
| | - Asma Mathlouthi
- Department of Surgery, Division of Vascular and Endovascular Surgery, University of California San Diego, 9444 Medical Center Drive, Number 3-22J, La Jolla, 92037 CA
| | - Omar Al-Nouri
- Department of Surgery, Division of Vascular and Endovascular Surgery, University of California San Diego, 9444 Medical Center Drive, Number 3-22J, La Jolla, 92037 CA
| | - Mahmoud B Malas
- Department of Surgery, Division of Vascular and Endovascular Surgery, University of California San Diego, 9444 Medical Center Drive, Number 3-22J, La Jolla, 92037 CA
| | - Andrew Barleben
- Department of Surgery, Division of Vascular and Endovascular Surgery, University of California San Diego, 9444 Medical Center Drive, Number 3-22J, La Jolla, 92037 CA
| |
Collapse
|
3
|
de Donato G, Pasqui E, Sirignano P, Talarico F, Palasciano G, Taurino M. Endovascular Abdominal Aortic Aneurysm Repair with Ovation Alto stent graft: Protocol of the ALTAIR study (ALTo endogrAft Italian Registry). (Preprint). JMIR Res Protoc 2022; 11:e36995. [PMID: 35816378 PMCID: PMC9315882 DOI: 10.2196/36995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 05/05/2022] [Accepted: 05/24/2022] [Indexed: 11/25/2022] Open
Abstract
Background Since 2010, the Ovation Abdominal Stent Graft System has offered an innovative sealing option for abdominal aortic aneurysm (AAA) by including a sealing ring filled with polymer 13 mm from the renal arteries. In August 2020, the redesigned Ovation Alto, with a sealing ring 6 mm closer to the top of the fabric, received CE Mark approval. Objective This registry study aims to evaluate intraoperative, perioperative, and postoperative results in patients treated by the Alto stent graft (Endologix Inc.) for elective AAA repair in a multicentric consecutive experience. Methods All consecutive eligible patients submitted to endovascular aneurysm repair (EVAR) by Alto Endovascular AAA implantation will be included in this analysis. Patients will be submitted to EVAR procedures based on their own preferences, anatomical features, and operators experience. An estimated number of 300 patients submitted to EVAR with Alto stent graft should be enrolled. It is estimated that the inclusion period will be 24 months. The follow-up period is set to be 5 years. Full data sets and cross-sectional images of contrast-enhanced computed tomography scan performed before EVAR, at the first postoperative month, at 24 or 36 months, and at 5-year follow-up interval will be reported in the central database for a centralized core laboratory review of morphological changes. The primary endpoint of the study is to evaluate the technical and clinical success of EVAR with the Alto stent graft in short- (90-day), mid- (1-year), and long-term (5-year) follow-up periods. The following secondary endpoints will be also addressed: operative time; intraoperative radiation exposure; contrast medium usage; AAA sac shrinkage at 12-month and 5-year follow-up; any potential role of patients’ baseline characteristics, valuated on preoperative computed tomography angiographic study, and of device configuration (number of component) in the primary endpoint. Results The study is currently in the recruitment phase and the final patient is expected to be treated by the end of 2023 and then followed up for 5 years. A total of 300 patients will be recruited. Analyses will focus on primary and secondary endpoints. Updated results will be shared at 1- and 3-5-year follow-ups. Conclusions The results from this registry study could validate the safety and effectiveness of the new design of the Ovation Alto Stent Graft. The technical modifications to the endograft could allow for accommodation of a more comprehensive range of anatomies on-label. Trial Registration ClinicalTrials.gov NCT05234892; https://clinicaltrials.gov/ct2/show/NCT05234892 International Registered Report Identifier (IRRID) PRR1-10.2196/36995
Collapse
Affiliation(s)
- Gianmarco de Donato
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Siena, Italy
| | - Edoardo Pasqui
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Siena, Italy
| | - Pasqualino Sirignano
- Vascular Surgery Unit, Sant'Andrea Hospital, University La Sapienza, Rome, Italy
| | | | - Giancarlo Palasciano
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Siena, Italy
| | - Maurizio Taurino
- Vascular Surgery Unit, Sant'Andrea Hospital, University La Sapienza, Rome, Italy
| |
Collapse
|
4
|
de Donato G, Pasqui E, Panzano C, Galzerano G, Cappelli A, Palasciano G. Early Experience with the New Ovation Alto Stent Graft in Endovascular Abdominal Aortic Aneurysm Repair. EJVES Vasc Forum 2021; 54:7-12. [PMID: 34950916 PMCID: PMC8671859 DOI: 10.1016/j.ejvsvf.2021.11.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2021] [Revised: 10/21/2021] [Accepted: 11/22/2021] [Indexed: 12/02/2022] Open
Abstract
INTRODUCTION Since 2010, the Ovation Abdominal Stent Graft System has offered a new sealing concept, achieved by a sealing ring filled with polymer 13 mm from the renal arteries. In the latest version, called Ovation Alto, the sealing ring is relocated 6 mm closer to the top of the fabric. This study describes the early clinical outcomes, after CE Mark approval in August 2020, of endovascular aneurysm repair with the Alto endograft. REPORT Eleven patients underwent endovascular aneurysm repair with implantation of Ovation Alto endografts. All patients were male, and the median age was 75 (IQR 5.5) years. Hostile proximal aortic neck (<10 mm) was identified in six cases (54.5%). All procedures were performed using bilateral percutaneous approaches with no groin complications. The median procedure time was 58 (IQR 7.2) minutes, the median contrast volume used was 65 (IQR 4.2) mL, and the median blood loss 40 (IQR 12.4) mL. Technical success was achieved in all cases. The median stent graft landing distance between the top of the fabric and the lowest renal artery was 1.4 (IQR 0.8) mm. No intra-operative high flow endoleaks were registered. At one and six month follow up, there was 100% clinical success (no type I/III endoleak, sac enlargement, stent graft migration, polymer leakage, abdominal aortic aneurysm related mortality, or secondary intervention). DISCUSSION Initial experience confirms the early technical and clinical success of the new Ovation Alto stent graft. Technical modifications to the endograft could allow for accommodation of a more comprehensive range of anatomies on label. Further studies are needed to evaluate long term durability outcomes.
Collapse
Affiliation(s)
- Gianmarco de Donato
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| | - Edoardo Pasqui
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| | - Claudia Panzano
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| | - Giuseppe Galzerano
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| | - Alessandro Cappelli
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| | - Giancarlo Palasciano
- Department of Medicine, Surgery, and Neuroscience, Vascular Surgery Unit, University of Siena, Italy
| |
Collapse
|
5
|
Özdemir-van Brunschot DMD, Torsello GB, Bernardini G, Litterscheid S, Torsello GF, Beropoulis E. Use of Chimney Technique Does Not Improve the Outcome of Endovascular Aneurysm Repair in Patients With a Hyperangulated and Short Proximal Aortic Neck. J Endovasc Ther 2021; 29:361-369. [PMID: 34622699 DOI: 10.1177/15266028211050315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE We hypothesized that extending the proximal landing zone with the chimney technique could be beneficial in patients with a hyperangulated proximal aortic neck, defined as more > 60 degrees. MATERIAL AND METHODS We retrospectively analyzed the outcome of prospectively collected data of patients treated by endovascular aneurysm repair (EVAR) for infrarenal aortic aneurysm with a hyperangulated proximal aortic neck. In all, 104 out of 130 patients were treated without (Group A) and 24 with the chimney endovascular aortic repair (ChEVAR, Group B). Primary outcome was technical and clinical success according to the reporting standards of the Society of Vascular Surgery. RESULTS The use of the chimney technique was associated with a significantly longer operation duration (167 vs. 93 min, p < .001), longer fluoroscopy time (44 vs.30 min, p = < .001), and larger amount of contrast medium used (149 vs. 127 ml, p = .03) but did not significantly improve technical (79.2% vs. 87.7%) and clinical success (54.2% vs. 68.9%). Aneurysm-related mortality was higher in group B (8.3% vs. = 0%, p < .001). Type IA endoleak was high in both groups at completion angiography (11.3% in Group A vs. 12.5% in Group B) and at follow-up (10.4% in Group A vs. 4.5% in Group B) without significant difference between the groups. CONCLUSIONS Our data did not show a benefit of the primary use of the chimney technique in patients with a hyperangulated and short neck, although more studies are required to support this conclusion. Other strategies or new technologies are required for improving EVAR results in aneurysm patients with severe angulated proximal and short neck.
Collapse
Affiliation(s)
| | | | - Giulia Bernardini
- Department of Vascular Surgery and Organ Transplant Unit, University Hospital of Catania, Catania, Italy
| | - Sarah Litterscheid
- Institute for Vascular Research, St. Franziskus Hospital, Münster, Germany
| | - Giovanni Federico Torsello
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Charité Campus Virchow-Klinikum, Charité University Medicine, Berlin, Germany
| | | |
Collapse
|
6
|
Marketou M, Papadopoulos G, Kontopodis N, Patrianakos A, Nakou E, Maragkoudakis S, Chlouverakis G, Stratakis S, Tavlas E, Parthenakis F, Ioannou CV. Early Left Ventricular Global Longitudinal Strain Deterioration After Aortic Aneurysm Repair: Impact of Aortic Stiffness. J Endovasc Ther 2020; 28:352-359. [PMID: 33412985 DOI: 10.1177/1526602820976636] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
PURPOSE To associate the impact of aortic reconstruction using currently available grafts and endografts on pulse wave velocity in patients with abdominal aortic aneurysm (AAA) and to evaluate its effect on early cardiac systolic function indices. MATERIALS AND METHODS Seventy-three consecutive patients with AAA (mean age 70±8 years; all men) who underwent open (n=12) or endovascular repair (EVAR; n=61) were prospectively enrolled in an observational cohort study. Left ventricular global longitudinal strain (GLS; an important diagnostic and prognostic index of early systolic dysfunction) and carotid-femoral pulse wave velocity (cf-PWV) were estimated 1 week preoperatively, as well as at 1 and 6 months postoperatively. RESULTS A significant time effect was found for cf-PWV, which showed an increase at 1 month that remained through 6 months (p=0.007). Additionally, a deterioration in GLS values was revealed, with a significant change at 1 month that persisted 6 months later (p<0.001). No significant group effect was observed between EVAR and open repair (p=0.98), and there was no significant interaction (p=0.96). Notably, the difference in GLS between baseline and 6 months significantly correlated with the corresponding changes in cf-PWV (r=0.494, p<0.001). CONCLUSION AAA repair leads not only to an increase in aortic stiffness, as measured by the increase in pulse wave velocity, but also to reduced cardiac systolic function. Our findings highlight the need for a more intense cardiac surveillance program after aortic reconstruction. Further studies are needed to investigate how this may translate into long-term manifestations of cardiovascular complications and symptomatology.
Collapse
Affiliation(s)
- Maria Marketou
- Cardiology Department, University Hospital of Heraklion, University of Crete Medical School, Heraklion, Crete, Greece
| | - George Papadopoulos
- Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital of Heraklion, University of Crete Medical School, Crete, Greece
| | - Nikolaos Kontopodis
- Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital of Heraklion, University of Crete Medical School, Crete, Greece
| | - Alexandros Patrianakos
- Cardiology Department, University Hospital of Heraklion, University of Crete Medical School, Heraklion, Crete, Greece
| | - Eleni Nakou
- Cardiology Department, University Hospital of Heraklion, University of Crete Medical School, Heraklion, Crete, Greece
| | - Spyros Maragkoudakis
- Cardiology Department, University Hospital of Heraklion, University of Crete Medical School, Heraklion, Crete, Greece
| | - Gregory Chlouverakis
- Division of Biostatistics, University Hospital of Heraklion, University of Crete Medical School, Crete, Greece
| | - Stavros Stratakis
- Nephrology Department, University Hospital of Heraklion, University of Crete Medical School, Crete, Greece
| | - Emmanouel Tavlas
- Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital of Heraklion, University of Crete Medical School, Crete, Greece
| | - Fragiskos Parthenakis
- Cardiology Department, University Hospital of Heraklion, University of Crete Medical School, Heraklion, Crete, Greece
| | - Christos V Ioannou
- Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital of Heraklion, University of Crete Medical School, Crete, Greece
| |
Collapse
|
7
|
Cannavale A, Lucatelli P, Corona M, Nardis P, Cannavale G, De Rubeis G, Santoni M, Maher B, Catalano C, Bezzi M. Current assessment and management of endoleaks after advanced EVAR: new devices, new endoleaks? Expert Rev Cardiovasc Ther 2020; 18:465-473. [PMID: 32634069 DOI: 10.1080/14779072.2020.1792294] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
INTRODUCTION In recent years there has been an increasing application of advanced EVAR techniques to tackle complex clinical and anatomical scenarios. In a bid to overcome the limitations of the traditional stent-grafts, newer EVAR endografts and techniques have been developed and introduced into clinical practice, permitting endovascular management of difficult infrarenal, juxta-renal and thoracoabdominal aneurysms for which previously there was no endovascular solution. As a consequence, we are now confronted with unique patterns of endoleak requiring customized clinical-radiological assessment and treatment. Despite the increasing body of evidence regarding new EVAR techniques and related endoleaks, current guidelines do not specifically address these issues. OBJECTIVES Our review aims to assess risk factors, development, and management strategies of these endoleaks, in the most recent infrarenal EVAR devices and in more complex fenestrated EVAR (FEVAR) and Chimney EVAR (Ch-EVAR). EXPERT OPINION Most new devices have demonstrated types of endoleaks that need specific imaging and treatment, as in EVAS, FEVAR, and ChEVAR. Knowledge of specific stent-graft characteristics and the nature of endoleaks associated with the various procedures facilitates the application of relevant useful imaging. In addition, it should aid development of a customized and practically relevant approach to patient management during intervention and follow-up.
Collapse
Affiliation(s)
- Alessandro Cannavale
- Vascular and Interventional Unit, Department of Radiological Sciences, Policlinico Umberto I, "Sapienza" University of Rome , Rome, Italy
| | - Pierleone Lucatelli
- Vascular and Interventional Unit, Department of Radiological Sciences, Policlinico Umberto I, "Sapienza" University of Rome , Rome, Italy
| | - Mario Corona
- Vascular and Interventional Unit, Department of Radiological Sciences, Policlinico Umberto I, "Sapienza" University of Rome , Rome, Italy
| | - Piergiorgio Nardis
- Vascular and Interventional Unit, Department of Radiological Sciences, Policlinico Umberto I, "Sapienza" University of Rome , Rome, Italy
| | - Giuseppe Cannavale
- Department of Radiological Sciences, "Sapienza" University of Rome , Rome, Italy
| | - Gianluca De Rubeis
- Vascular and Interventional Unit, Department of Radiological Sciences, Policlinico Umberto I, "Sapienza" University of Rome , Rome, Italy
| | - Mariangela Santoni
- Department of Radiological Sciences, "Sapienza" University of Rome , Rome, Italy
| | - Ben Maher
- Department of Interventional Radiology, University Hospital Southampton NHS Foundation Trust , Southampton, UK
| | - Carlo Catalano
- Department of Radiological Sciences, "Sapienza" University of Rome , Rome, Italy
| | - Mario Bezzi
- Vascular and Interventional Unit, Department of Radiological Sciences, Policlinico Umberto I, "Sapienza" University of Rome , Rome, Italy
| |
Collapse
|
8
|
De León Ayala IA, Cheng YT, Chen SW, Chu SY, Nan YY, Liu KS. Outcomes of type Ia endoleaks after endovascular repair of the proximal aorta. J Thorac Cardiovasc Surg 2020; 163:2012-2021.e6. [PMID: 32773121 DOI: 10.1016/j.jtcvs.2020.06.026] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2020] [Revised: 06/13/2020] [Accepted: 06/17/2020] [Indexed: 01/16/2023]
Abstract
OBJECTIVE Thoracic endovascular aortic repair (TEVAR) can be complicated by a type Ia endoleak. However, its natural history remains unclear. This report describes the natural history and midterm outcome of conservatively treated type Ia endoleaks in the proximal aorta. METHODS Between 2007 and 2015, 395 patients underwent TEVAR at our institution. Only TEVARs landing proximally at landing zones 0, 1, and 2 were included (221/395). Type Ia endoleak's flow was classified as "fast" or "slow" based on the time needed to visualize the aneurysmal sac during arteriogram. RESULTS The median follow-up was 4.1 years. Aortic dissection, thoracic aortic aneurysm, and traumatic aortic injury were the most common indications for TEVAR; the incidence of type Ia endoleak was not statistically different. Forty-seven patients (21.3%) had a type Ia endoleak. TEVAR landing proximally at zone 1 increased the odds of developing a type Ia endoleak (odds ratio, 2.8; 95% confidence interval, 1.3-5.9; P = .0072). The 30-day mortality and the overall survival was not influenced by the development of immediate-type Ia endoleak. In 34 (72.3%) patients, the endoleak resolved spontaneously. Ninety-four percent of these patients had a SlowE (n = 32/34). All of spontaneous resolutions occurred before the end of the first postoperative year. CONCLUSIONS SlowE tends to resolve within 1 year after TEVAR. Initial conservative treatment seems to be a reasonable approach in patients with SlowE.
Collapse
Affiliation(s)
- Iván Alejandro De León Ayala
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Yu-Ting Cheng
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Shao-Wei Chen
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan; Center for Big Data Analytics and Statistics, Chang Gung Memorial Hospital, Linkou Medical Center, Taoyuan City, Taiwan
| | - Sung-Yu Chu
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Yu-Yun Nan
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan
| | - Kuo-Sheng Liu
- Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan.
| |
Collapse
|
9
|
Endurant stent graft demonstrates promising outcomes in challenging abdominal aortic aneurysm anatomy. J Vasc Surg 2020; 73:69-80. [PMID: 32442605 DOI: 10.1016/j.jvs.2020.04.508] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 04/16/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVE We aimed to assess the 5-year safety and effectiveness outcomes of patients enrolled in the Endurant Stent Graft Natural Selection Global Post Market Registry (ENGAGE) who were treated outside the approved indications for use (IFU) of the Endurant stent graft. METHODS Our primary outcome measure was 12-month treatment success, defined as successful endograft delivery and deployment and the absence of type I or III endoleak, stent migration or limb occlusion, late conversion, and abdominal aortic aneurysm diameter increase or rupture. Secondary outcome measures included 30-day all-cause mortality, major adverse events, secondary procedures, technical observations, aneurysm-related mortality, and all-cause mortality within 12 months. RESULTS Demographic characteristics of ENGAGE patients treated outside (225 [17.8%]) and within (1038 [82.2%]) the IFUs were similar, except that female patients comprised a much higher percentage of the outside IFU group (19.1% vs 8.7%; P < .001). The outside IFU group presented with lower rates of coronary artery disease and cardiac revascularization and a greater number of symptomatic patients compared with the within IFU group (21.3% vs 15.0%; P = .020). Technical success was achieved in more than 99% of all patients. The outside and within IFU groups showed a comparable and low occurrence of uncorrected type I (0.9% vs 1.2%; P = 1.00) and type III endoleak (0.4% vs 0.3%; P = .54) immediately after device implantation. The 5-year freedom from type IA endoleaks was 89.4% vs 96.7% (P < .0001) for those patients outside and within the IFUs, respectively, although both groups had similar type III endoleaks through 5 years (P = .61). Stent graft limb occlusion estimated overall survival, and freedom from aneurysm-related mortality and endovascular interventions were comparable in both patient groups through the 5-year follow-up. The Kaplan-Meier estimates at 5 years showed a trend for low but increased need for type I or III endoleak correction procedures in the outside IFU group compared with the within IFU group (7.2% vs 5.2%; P = .099). CONCLUSIONS Differences were not observed in all-cause mortality, aneurysm-related mortality, and secondary procedures between within and outside IFU patients through a 5-year follow-up in the ENGAGE registry. Proximal necks with angulation or diameters outside the IFUs were the most common reasons for patients identified as being outside IFU, and the cohort had increased incidence of type IA endoleaks. Despite the challenges presented from the broad range of aortic and abdominal aortic aneurysm morphologies, the Endurant stent graft showed promising 5-year outcomes.
Collapse
|
10
|
Mid- to Long-Term Outcome Results of the Ovation Stent Graft. Ann Vasc Surg 2020; 63:129-135. [DOI: 10.1016/j.avsg.2019.06.045] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 06/24/2019] [Accepted: 06/28/2019] [Indexed: 12/20/2022]
|
11
|
Bewley BR, Servais AB, Salehi P. The evolution of stent grafts for endovascular repair of abdominal aortic aneurysms: how design changes affect clinical outcomes. Expert Rev Med Devices 2019; 16:965-980. [DOI: 10.1080/17434440.2019.1684897] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
| | | | - Payam Salehi
- Tufts University School of Medicine, Boston, MA, USA
- Department of Surgery, Tufts Medical Center, Boston, MA, USA
| |
Collapse
|
12
|
Perini P, Bianchini Massoni C, Mariani E, Ucci A, Fanelli M, Azzarone M, Freyrie A. Systematic Review and Meta-Analysis of the Outcome of Different Treatments for Type 1a Endoleak After EVAR. Ann Vasc Surg 2019; 60:435-446.e1. [DOI: 10.1016/j.avsg.2019.03.032] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2019] [Revised: 03/04/2019] [Accepted: 03/11/2019] [Indexed: 12/29/2022]
|
13
|
Georgakarakos E, Koutsoumpelis A, Tasopoulou KM, Georgiadis GS. Tips to Ensure Optimal Ring Apposition of the Ovation Stent Graft in Challenging Necks of Abdominal Aortic Aneurysms. AORTA : OFFICIAL JOURNAL OF THE AORTIC INSTITUTE AT YALE-NEW HAVEN HOSPITAL 2019; 7:67-69. [PMID: 31529432 PMCID: PMC6748839 DOI: 10.1055/s-0039-1688434] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The Ovation stent graft has been recently introduced for endovascular repair of abdominal aortic aneurysms. Its sealing mechanism is based on a pair of polymer-filled inflatable rings. Based on our experience, we describe useful tips to optimize the use of Ovation in thrombosed or severely angulated necks.
Collapse
Affiliation(s)
- Efstratios Georgakarakos
- Department of Vascular Surgery, University Hospital of Alexandroupolis, "Democritus" University of Thrace, Alexandroupolis, Greece
| | - Andreas Koutsoumpelis
- Department of Vascular Surgery, University Hospital of Alexandroupolis, "Democritus" University of Thrace, Alexandroupolis, Greece
| | - Kalliopi-Maria Tasopoulou
- Department of Vascular Surgery, University Hospital of Alexandroupolis, "Democritus" University of Thrace, Alexandroupolis, Greece
| | - George S Georgiadis
- Department of Vascular Surgery, University Hospital of Alexandroupolis, "Democritus" University of Thrace, Alexandroupolis, Greece
| |
Collapse
|