1
|
Elnagar N, Elgiddawy N, El Rouby WMA, Farghali AA, Korri-Youssoufi H. Impedimetric Detection of Cancer Markers Based on Nanofiber Copolymers. BIOSENSORS 2024; 14:77. [PMID: 38391996 PMCID: PMC10887276 DOI: 10.3390/bios14020077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 01/23/2024] [Accepted: 01/29/2024] [Indexed: 02/24/2024]
Abstract
The sensitive determination of folate receptors (FRs) in the early stages of cancer is of great significance for controlling the progression of cancerous cells. Many folic acid (FA)-based electrochemical biosensors have been utilized to detect FRs with promising performances, but most were complicated, non-reproducible, non-biocompatible, and time and cost consuming. Here, we developed an environmentally friendly and sensitive biosensor for FR detection. We proposed an electrochemical impedimetric biosensor formed by nanofibers (NFs) of bio-copolymers prepared by electrospinning. The biosensor combines the advantages of bio-friendly polymers, such as sodium alginate (SA) and polyethylene oxide (PEO) as an antifouling polymer, with FA as a biorecognition element. The NF nanocomposites were characterized using various techniques, including SEM, FTIR, zeta potential (ZP), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). We evaluated the performance of the NF biosensor using EIS and demonstrated FR detection in plasma with a limit of detection of 3 pM. Furthermore, the biosensor showed high selectivity, reliability, and good stability when stored for two months. This biosensor was constructed from 'green credentials' holding polymers that are highly needed in the new paradigm shift in the medical industry.
Collapse
Affiliation(s)
- Noha Elnagar
- Materials Science and Nanotechnology Department, Faculty of Postgraduate Studies for Advanced Sciences (PSAS), Beni-Suef University, Beni-Suef 62 511, Egypt; (N.E.); (W.M.A.E.R.); (A.A.F.)
- Université Paris-Saclay, Centre National de la Recherche Scientifique (CNRS), Institut de Chimie Moléculaire et des Matériaux d’Orsay (ICMMO), ECBB, 17 Avenue des Sciences, Site Henri Moisson, 91400 Orsay, France
| | - Nada Elgiddawy
- Department of Biotechnology and Life Sciences, Faculty of Postgraduate Studies for Advanced Sciences (PSAS), Beni-Suef University, Beni-Suef 62 511, Egypt;
| | - Waleed M. A. El Rouby
- Materials Science and Nanotechnology Department, Faculty of Postgraduate Studies for Advanced Sciences (PSAS), Beni-Suef University, Beni-Suef 62 511, Egypt; (N.E.); (W.M.A.E.R.); (A.A.F.)
| | - Ahmed A. Farghali
- Materials Science and Nanotechnology Department, Faculty of Postgraduate Studies for Advanced Sciences (PSAS), Beni-Suef University, Beni-Suef 62 511, Egypt; (N.E.); (W.M.A.E.R.); (A.A.F.)
| | - Hafsa Korri-Youssoufi
- Université Paris-Saclay, Centre National de la Recherche Scientifique (CNRS), Institut de Chimie Moléculaire et des Matériaux d’Orsay (ICMMO), ECBB, 17 Avenue des Sciences, Site Henri Moisson, 91400 Orsay, France
| |
Collapse
|
2
|
Kaur A, Lavisha, Chaudhary GR, Prabhakar N. MC-Au/MSS-Z8 porous network assisted advanced electrochemical immunosensing of 25-hydroxyvitamin D 3. Talanta 2023; 257:124376. [PMID: 36821967 DOI: 10.1016/j.talanta.2023.124376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 12/28/2022] [Accepted: 02/14/2023] [Indexed: 02/17/2023]
Abstract
On-site monitoring of vitamin D levels is subject matter of immediate attention owing to the serious aftermath of its long standing deficiency. Therefore, a novel and efficient voltammetric immunosensing of 25-hydroxyvitamin D3 (25(OH)VD3) has been experimented based on an advanced sensing platform composed of meso-microporous silica-zeolitic imidazolate framework-8 (MSS-Z8) with highly enhanced surface area (SBET, MSS-Z8 (643.4 m2g-1) > SBET, MSS (49.95 m2g-1)), embedded with gold particles (mass loading of 82 μg), particularly of microcubic morphology (MC-Au). Further, the MC-Au/MSS-Z8/FTO platform was fashioned with antibody specific to 25(OH)VD3 via interaction between Au and abundant -SH groups present on the antibody surface. After optimization of operational parameters, the Ab/MC-Au/MSS-Z8/FTO immunosensor was employed for the determination of 25(OH)VD3 within 0.01-106 pg mL-1 concentration range through differential pulse voltammetry technique in [Fe(CN)6]3-/4-. Thus, 0.01 pg mL-1 concentration of 25(OH)VD3 was the experimental limit of detection of the immunosensor. Further, upon examination of various analytical parameters, it turns out that the immunosensor exhibited low theoretical LOD (0.23 pg mL-1) and LOQ (0.76 pg mL-1), wide linear range (0.01-106 pg mL-1), ultra-sensitivity (143.9 μA [log (pg mL-1)]-1 cm-2), adequate reproducibility (RSD ≤1.23%) and acceptable shelf life. Most importantly, the immunosensor presented proficient performance with spiked human serum samples (Recovery = 97.20-100.7%, RSD value < 5.6%), evincing the adequacy of present biosensing approach.
Collapse
Affiliation(s)
- Amandeep Kaur
- Department of Biochemistry, Panjab University, Chandigarh, 160014, India; Department of Chemistry and Centre for Advanced Studies in Chemistry, Panjab University, Chandigarh, 160014, India
| | - Lavisha
- Department of Biochemistry, Panjab University, Chandigarh, 160014, India
| | - Ganga Ram Chaudhary
- Department of Chemistry and Centre for Advanced Studies in Chemistry, Panjab University, Chandigarh, 160014, India; SAIF/CIL, Panjab University, Chandigarh, 160014, India
| | - Nirmal Prabhakar
- Department of Biochemistry, Panjab University, Chandigarh, 160014, India.
| |
Collapse
|
3
|
Naik M, Kamath U S, Uppangala S, Adiga SK, Patil A. Vitamin D metabolites and analytical challenges. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:399-410. [PMID: 36628933 DOI: 10.1039/d2ay01692c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Vitamin D is an essential micronutrient for bone health and the general cellular functions of the body. Its insufficiency/deficiency leads to the pathophysiology of disorders like diabetes, cancer, autoimmune, neurodegenerative, and cardiovascular diseases. Clinical interest in Vitamin D metabolites and their role in various medical disorders have contributed to an increase in laboratory demands for vitamin D measurements. For clinical and research laboratories worldwide, analysis of vitamin D and associated metabolites is a significant problem. The best way for determining vitamin D levels is constantly being debated. Various methods such as immunoassays and chromatographic techniques are available for determining vitamin D levels. Additionally, biosensors have recently been considered promising options for routine vitamin D analysis. The existing methods and other developments in the measurement of vitamin D metabolites and associated analytical challenges are discussed in this review.
Collapse
Affiliation(s)
- Megha Naik
- Department of Atomic and Molecular Physics, Manipal Academy of Higher Education (MAHE), India-576 104.
| | - Saritha Kamath U
- Department of Medical Laboratory Technology, Manipal College of Health Professions, Manipal Academy of Higher Education (MAHE), Manipal, India-576 104
| | - Shubhashree Uppangala
- Division of Reproductive Genetics, Department of Reproductive Science, Kasturba Medical College, Manipal Academy of Higher Education (MAHE), Manipal, India-576 104
| | - Satish Kumar Adiga
- Division of Clinical Embryology, Department of Reproductive Science, Kasturba Medical College, Manipal Academy of Higher Education (MAHE), Manipal, India-576 104
| | - Ajeetkumar Patil
- Department of Atomic and Molecular Physics, Manipal Academy of Higher Education (MAHE), India-576 104.
| |
Collapse
|
4
|
Nimbkar S, Leena MM, Moses JA, Anandharamakrishnan C. Microfluidic assessment of nutritional biomarkers: Concepts, approaches and advances. Crit Rev Food Sci Nutr 2022; 64:5113-5127. [PMID: 36503314 DOI: 10.1080/10408398.2022.2150597] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Among various approaches to understand the health status of an individual, nutritional biomarkers can provide valuable information, particularly in terms of deficiencies, if any, and their severity. Commonly, the approach revolves around molecular sciences, and the information gained can support prognosis, diagnosis, remediation, and impact assessment of therapies. Microfluidic platforms can offer benefits of low sample and reagent requirements, low cost, high precision, and lower detection limits, with simplicity in handling and the provision for complete automation and integration with information and communication technologies (ICTs). While several advances are being made, this work details the underlying concepts, with emphasis on different point-of-care devices for the analysis of macro and micronutrient biomarkers. In addition, the scope of using different wearable microfluidic sensors for real-time and noninvasive determination of biomarkers is detailed. While several challenges remain, a strong focus is given on recent advances, presenting the state-of-the-art of this field. With more such biomarkers being discovered and commercialization-driven research, trends indicate the wide prospects of this advancing field in supporting clinicians, food technologists, nutritionists, and others.
Collapse
Affiliation(s)
- Shubham Nimbkar
- Computational Modeling and Nanoscale Processing Unit, National Institute of Food Technology, Entrepreneurship and Management, Ministry of Food Processing Industries, Thanjavur, Tamil Nadu, India
| | - M Maria Leena
- Computational Modeling and Nanoscale Processing Unit, National Institute of Food Technology, Entrepreneurship and Management, Ministry of Food Processing Industries, Thanjavur, Tamil Nadu, India
| | - Jeyan Arthur Moses
- Computational Modeling and Nanoscale Processing Unit, National Institute of Food Technology, Entrepreneurship and Management, Ministry of Food Processing Industries, Thanjavur, Tamil Nadu, India
| | - Chinnaswamy Anandharamakrishnan
- Computational Modeling and Nanoscale Processing Unit, National Institute of Food Technology, Entrepreneurship and Management, Ministry of Food Processing Industries, Thanjavur, Tamil Nadu, India
| |
Collapse
|
5
|
Randviir EP, Banks CE. A review of electrochemical impedance spectroscopy for bioanalytical sensors. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:4602-4624. [PMID: 36342043 DOI: 10.1039/d2ay00970f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Electrochemical impedance spectroscopy (EIS) is a powerful technique for both quantitative and qualitative analysis. This review uses a systematic approach to examine how electrodes are tailored for use in EIS-based applications, describing the chemistries involved in sensor design, and discusses trends in the use of bio-based and non-bio-based electrodes. The review finds that immunosensors are the most prevalent sensor strategy that employs EIS as a quantification technique for target species. The review also finds that bio-based electrodes, though capable of detecting small molecules, are most applicable for the detection of complex molecules. Non-bio-based sensors are more often employed for simpler molecules and less often have applications for complex systems. We surmise that EIS has advanced in terms of electrode designs since our last review on the subject, although there are still inconsistencies in terms of equivalent circuit modelling for some sensor types. Removal of ambiguity from equivalent circuit models may help advance EIS as a choice detection method, allowing for lower limits of detection than traditional electrochemical methods such as voltammetry or amperometry.
Collapse
Affiliation(s)
- Edward P Randviir
- Department of Natural Sciences, Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, Lancs, UK.
| | - Craig E Banks
- Department of Natural Sciences, Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, Lancs, UK.
| |
Collapse
|
6
|
β-cyclodextrin functionalized graphitic carbon nitride as a promising electrocatalyst for the selective oxidation of Tetrahydrofurfuryl alcohol. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.141109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
7
|
Zhang T, Du X, Zhang Z. Advances in electrochemical sensors based on nanomaterials for the detection of lipid hormone. Front Bioeng Biotechnol 2022; 10:993015. [PMID: 36159660 PMCID: PMC9500180 DOI: 10.3389/fbioe.2022.993015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Accepted: 08/12/2022] [Indexed: 11/17/2022] Open
Abstract
Lipid hormone is produced by highly differentiated endocrine cells and directly secretes into the blood circulation or tissue fluid to act as information transmission. It influences the physiological functions of the human body by controlling the metabolic processes of multiple tissue cells. Monitoring the levels of lipid hormone is of great importance for maintaining human health. The electrochemical sensor is considered as an ideal tool to detect lipid hormone owing to its advantages such as quick response, convenience and low economic costs. In recent 3 years, researchers have developed various electrochemical sensors for the detection of lipid hormone to improve their sensitivity or selectivity. The use of nanomaterials (such as carbon nanomaterials, precious metal and polymer) is a key research object and a breakthrough for improving the sensing performance of electrochemical sensors for detection of lipid hormone. This paper reviews and discusses the basic principle, nanomaterials, actuality and future development trend of electrochemical sensors for the detection of lipid hormone in the past 3 years.
Collapse
Affiliation(s)
| | - Xin Du
- *Correspondence: Xin Du, ; Zhenguo Zhang,
| | | |
Collapse
|
8
|
Arafa KK, Ibrahim A, Mergawy R, El-Sherbiny IM, Febbraio F, Hassan RYA. Advances in Cancer Diagnosis: Bio-Electrochemical and Biophysical Characterizations of Cancer Cells. MICROMACHINES 2022; 13:mi13091401. [PMID: 36144024 PMCID: PMC9504238 DOI: 10.3390/mi13091401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/21/2022] [Accepted: 08/23/2022] [Indexed: 05/09/2023]
Abstract
Cancer is a worldwide leading cause of death, and it is projected that newly diagnosed cases globally will reach 27.5 million each year by 2040. Cancers (malignant tumors), unlike benign tumors are characterized by structural and functional dedifferentiation (anaplasia), breaching of the basement membrane, spreading to adjacent tissues (invasiveness), and the capability to spread to distant sites (metastasis). In the cancer biology research field, understanding and characterizing cancer metastasis as well as features of cell death (apoptosis) is considered a technically challenging subject of study and clinically is very critical and necessary. Therefore, in addition to the cytochemical methods traditionally used, novel biophysical and bioelectrochemical techniques (e.g., cyclic voltammetry and electrochemical impedance spectroscopy), atomic force microscopy, and electron microscopic methods are increasingly being deployed to better understand these processes. Implementing those methods at the preclinical level enables the rapid screening of new anticancer drugs with understanding of their central mechanism for cancer therapy. In this review, principles and basic concepts of new techniques suggested for metastasis, and apoptosis examinations for research purposes are introduced, along with examples of each technique. From our recommendations, the privilege of combining the bio-electrochemical and biosensing techniques with the conventional cytochemical methods either for research or for biomedical diagnosis should be emphasized.
Collapse
Affiliation(s)
- Kholoud K. Arafa
- Nanoscience Program, University of Science and Technology (UST), Zewail City of Science and Technology, Giza 12578, Egypt
| | - Alaa Ibrahim
- Nanoscience Program, University of Science and Technology (UST), Zewail City of Science and Technology, Giza 12578, Egypt
| | - Reem Mergawy
- Nanoscience Program, University of Science and Technology (UST), Zewail City of Science and Technology, Giza 12578, Egypt
| | - Ibrahim M. El-Sherbiny
- Nanoscience Program, University of Science and Technology (UST), Zewail City of Science and Technology, Giza 12578, Egypt
| | - Ferdinando Febbraio
- Institute of Biochemistry and Cell Biology, National Research Council (CNR), Via P. Castellino 111, 80131 Naples, Italy
| | - Rabeay Y. A. Hassan
- Nanoscience Program, University of Science and Technology (UST), Zewail City of Science and Technology, Giza 12578, Egypt
- Correspondence: ; Tel.: +20-1129216152
| |
Collapse
|
9
|
Vásquez V, Orozco J. Detection of COVID-19-related biomarkers by electrochemical biosensors and potential for diagnosis, prognosis, and prediction of the course of the disease in the context of personalized medicine. Anal Bioanal Chem 2022; 415:1003-1031. [PMID: 35970970 PMCID: PMC9378265 DOI: 10.1007/s00216-022-04237-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 06/30/2022] [Accepted: 07/18/2022] [Indexed: 02/07/2023]
Abstract
As a more efficient and effective way to address disease diagnosis and intervention, cutting-edge technologies, devices, therapeutic approaches, and practices have emerged within the personalized medicine concept depending on the particular patient's biology and the molecular basis of the disease. Personalized medicine is expected to play a pivotal role in assessing disease risk or predicting response to treatment, understanding a person's health status, and, therefore, health care decision-making. This work discusses electrochemical biosensors for monitoring multiparametric biomarkers at different molecular levels and their potential to elucidate the health status of an individual in a personalized manner. In particular, and as an illustration, we discuss several aspects of the infection produced by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) as a current health care concern worldwide. This includes SARS-CoV-2 structure, mechanism of infection, biomarkers, and electrochemical biosensors most commonly explored for diagnostics, prognostics, and potentially assessing the risk of complications in patients in the context of personalized medicine. Finally, some concluding remarks and perspectives hint at the use of electrochemical biosensors in the frame of other cutting-edge converging/emerging technologies toward the inauguration of a new paradigm of personalized medicine.
Collapse
Affiliation(s)
- Viviana Vásquez
- grid.412881.60000 0000 8882 5269Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, Medellín, 050010 Colombia
| | - Jahir Orozco
- grid.412881.60000 0000 8882 5269Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, Medellín, 050010 Colombia
| |
Collapse
|
10
|
Engineering ZnO nanocrystals anchored on mesoporous TiO2 for simultaneous detection of vitamins. Biochem Eng J 2022. [DOI: 10.1016/j.bej.2022.108585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
11
|
Martins TS, Bott-Neto JL, Machado SAS, Oliveira ON. Label-Free Electrochemical Immunosensor Made with Tree-like Gold Dendrites for Monitoring 25-Hydroxyvitamin D3 Metabolite. ACS APPLIED MATERIALS & INTERFACES 2022; 14:31455-31462. [PMID: 35776164 DOI: 10.1021/acsami.2c08381] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Flexible, fully printed immunosensors can meet the requirements of precision nutrition, but this demands optimized molecular architectures to reach the necessary sensitivity. Herein, we report on flexible and label-free immunosensor chips made with tree-like gold dendrites (AuDdrites) electrochemically formed by selective desorption of l-cysteine (L-cys) on (111) gold planes. Electrodeposition was used because it is scalable and cost-effective for a rapid, direct growth of Au hyperbranched dendritic structures. The 25-hydroxyvitamin D3 (25(OH)D3) metabolite was detected within 15 min with a limit of detection (LOD) of 0.03 ng mL-1. This high performance was possible due to the careful optimization of the electroactive layer and working conditions for square wave voltammetry (SWV). Electrocrystallization was manipulated by controlling the deposition potential and the molar ratio between HAuCl4 and L-cys. Metabolite detection was performed on human serum and saliva samples with adequate recovery between 97% and 100%. The immunosensors were stable and reproducible, unresponsive to interference from other molecules in human serum and saliva. They can be extended for use as wearable sensors with their mechanical flexibility and possible customization.
Collapse
Affiliation(s)
- Thiago S Martins
- São Carlos Institute of Chemistry, University of São Paulo, 13560-970 São Carlos, SP, Brazil
| | - José L Bott-Neto
- São Carlos Institute of Physics, University of São Paulo, 13560-970 São Carlos, SP, Brazil
| | - Sergio A S Machado
- São Carlos Institute of Chemistry, University of São Paulo, 13560-970 São Carlos, SP, Brazil
| | - Osvaldo N Oliveira
- São Carlos Institute of Physics, University of São Paulo, 13560-970 São Carlos, SP, Brazil
| |
Collapse
|
12
|
Hussein HA, Kandeil A, Gomaa M, Mohamed El Nashar R, El-Sherbiny IM, Hassan RYA. SARS-CoV-2-Impedimetric Biosensor: Virus-Imprinted Chips for Early and Rapid Diagnosis. ACS Sens 2021; 6:4098-4107. [PMID: 34757734 PMCID: PMC8592124 DOI: 10.1021/acssensors.1c01614] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 11/01/2021] [Indexed: 12/19/2022]
Abstract
Due to the current global SARS-CoV-2 pandemic, rapid and accurate diagnostic tools are needed to prevent the spread of COVID-19 across the globe. An electrochemical sensing platform was constructed using CNTs/WO3-screen printed electrodes for imprinting the complete virus particles (SARS-CoV-2 particles) within the polymeric matrix to create viral complementary binding sites. The sensor provided high selectivity toward the target virus over other tested human corona and influenza respiratory interference viruses. The sensitivity performance of the sensor chips was evaluated using different viral concentrations, while the limits of detection and quantification were 57 and 175 pg/mL, respectively. Reaching this satisfied low detection limit (almost 27-fold more sensitive than the RT-PCR), the sensor was applied in clinical specimens obtained from SARS-CoV-2 suspected cases. Thus, dealing directly with clinical samples on the chip could be provided as a portable device for instantaneous and simple point of care in hospitals, airports, and hotspots.
Collapse
Affiliation(s)
- Heba A. Hussein
- Virology Department, Animal Health
Research Institute (AHRI), Agricultural Research Center (ARC), Giza 12619,
Egypt
| | - Ahmed Kandeil
- Center of Scientific Excellence for Influenza Viruses,
Environmental Research Division, National Research Centre, Giza
12622, Egypt
| | - Mokhtar Gomaa
- Center of Scientific Excellence for Influenza Viruses,
Environmental Research Division, National Research Centre, Giza
12622, Egypt
| | | | - Ibrahim M. El-Sherbiny
- Nanoscience Program, University of
Science and Technology (UST), Zewail City of Science and Technology, Giza
12578, Egypt
| | - Rabeay Y. A. Hassan
- Nanoscience Program, University of
Science and Technology (UST), Zewail City of Science and Technology, Giza
12578, Egypt
- Applied Organic Chemistry Department,
National Research Centre (NRC), Dokki, 12622 Giza,
Egypt
| |
Collapse
|
13
|
Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications. SENSORS 2021; 21:s21196578. [PMID: 34640898 PMCID: PMC8512860 DOI: 10.3390/s21196578] [Citation(s) in RCA: 175] [Impact Index Per Article: 58.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 09/17/2021] [Accepted: 09/26/2021] [Indexed: 01/10/2023]
Abstract
Electrochemical impedance spectroscopy (EIS) is a powerful technique used for the analysis of interfacial properties related to bio-recognition events occurring at the electrode surface, such as antibody–antigen recognition, substrate–enzyme interaction, or whole cell capturing. Thus, EIS could be exploited in several important biomedical diagnosis and environmental applications. However, the EIS is one of the most complex electrochemical methods, therefore, this review introduced the basic concepts and the theoretical background of the impedimetric technique along with the state of the art of the impedimetric biosensors and the impact of nanomaterials on the EIS performance. The use of nanomaterials such as nanoparticles, nanotubes, nanowires, and nanocomposites provided catalytic activity, enhanced sensing elements immobilization, promoted faster electron transfer, and increased reliability and accuracy of the reported EIS sensors. Thus, the EIS was used for the effective quantitative and qualitative detections of pathogens, DNA, cancer-associated biomarkers, etc. Through this review article, intensive literature review is provided to highlight the impact of nanomaterials on enhancing the analytical features of impedimetric biosensors.
Collapse
|