1
|
Sitkov N, Ryabko A, Moshnikov V, Aleshin A, Kaplun D, Zimina T. Hybrid Impedimetric Biosensors for Express Protein Markers Detection. MICROMACHINES 2024; 15:181. [PMID: 38398911 PMCID: PMC10890403 DOI: 10.3390/mi15020181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 01/22/2024] [Accepted: 01/23/2024] [Indexed: 02/25/2024]
Abstract
Impedimetric biosensors represent a powerful and promising tool for studying and monitoring biological processes associated with proteins and can contribute to the development of new approaches in the diagnosis and treatment of diseases. The basic principles, analytical methods, and applications of hybrid impedimetric biosensors for express protein detection in biological fluids are described. The advantages of this type of biosensors, such as simplicity and speed of operation, sensitivity and selectivity of analysis, cost-effectiveness, and an ability to be integrated into hybrid microfluidic systems, are demonstrated. Current challenges and development prospects in this area are analyzed. They include (a) the selection of materials for electrodes and formation of nanostructures on their surface; (b) the development of efficient methods for biorecognition elements' deposition on the electrodes' surface, providing the specificity and sensitivity of biosensing; (c) the reducing of nonspecific binding and interference, which could affect specificity; (d) adapting biosensors to real samples and conditions of operation; (e) expanding the range of detected proteins; and, finally, (f) the development of biosensor integration into large microanalytical system technologies. This review could be useful for researchers working in the field of impedimetric biosensors for protein detection, as well as for those interested in the application of this type of biosensor in biomedical diagnostics.
Collapse
Affiliation(s)
- Nikita Sitkov
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
- Engineering Centre for Microtechnology and Diagnostics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| | - Andrey Ryabko
- Laboratory of Nonequilibrium Processes in Semiconductors, Ioffe Institute, 26 Politekhnicheskaya, 194021 Saint Petersburg, Russia;
| | - Vyacheslav Moshnikov
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
| | - Andrey Aleshin
- Laboratory of Nonequilibrium Processes in Semiconductors, Ioffe Institute, 26 Politekhnicheskaya, 194021 Saint Petersburg, Russia;
| | - Dmitry Kaplun
- Artificial Intelligence Research Institute, China University of Mining and Technology, 1 Daxue Road, Xuzhou 221116, China;
- Department of Automation and Control Processes, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| | - Tatiana Zimina
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
- Engineering Centre for Microtechnology and Diagnostics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| |
Collapse
|
2
|
Stanković V, Đurđić S, Ognjanović M, Zlatić G, Stanković D. Triangle-Shaped Cerium Tungstate Nanoparticles Used to Modify Carbon Paste Electrode for Sensitive Hydroquinone Detection in Water Samples. SENSORS (BASEL, SWITZERLAND) 2024; 24:705. [PMID: 38276396 PMCID: PMC10818471 DOI: 10.3390/s24020705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 01/12/2024] [Accepted: 01/17/2024] [Indexed: 01/27/2024]
Abstract
In this study, we propose an eco-friendly method for synthesizing cerium tungstate nanoparticles using hydrothermal techniques. We used scanning, transmission electron microscopy, and X-ray diffraction to analyze the morphology of the synthesized nanoparticles. The results showed that the synthesized nanoparticles were uniform and highly crystalline, with a particle size of about 50 nm. The electrocatalytic properties of the nanoparticles were then investigated using cyclic voltammetry and electrochemical impedance spectroscopy. We further used the synthesized nanoparticles to develop an electrochemical sensor based on a carbon paste electrode that can detect hydroquinone. By optimizing the differential pulse voltammetric method, a wide linearity range of 0.4 to 45 µM and a low detection limit of 0.06 µM were obtained. The developed sensor also expressed excellent repeatability (RSD up to 3.8%) and reproducibility (RSD below 5%). Interferences had an insignificant impact on the determination of analytes, making it possible to use this method for monitoring hydroquinone concentrations in tap water. This study introduces a new approach to the chemistry of materials and the environment and demonstrates that a careful selection of components can lead to new horizons in analytical chemistry.
Collapse
Affiliation(s)
- Vesna Stanković
- Institute for Chemistry, Technology and Metallurgy, University of Belgrade, 11000 Belgrade, Serbia;
| | - Slađana Đurđić
- Faculty of Chemistry, University of Belgrade, 11000 Belgrade, Serbia;
| | - Miloš Ognjanović
- Institute for Nuclear Science Vinča, University of Belgrade, 11000 Belgrade, Serbia;
| | - Gloria Zlatić
- Faculty of Science and Education, University of Mostar, 88000 Mostar, Bosnia and Herzegovina;
| | - Dalibor Stanković
- Faculty of Chemistry, University of Belgrade, 11000 Belgrade, Serbia;
| |
Collapse
|
3
|
Đurđić S, Vlahović F, Ognjanović M, Gemeiner P, Sarakhman O, Stanković V, Mutić J, Stanković D, Švorc Ľ. Nano-size cobalt-doped cerium oxide particles embedded into graphitic carbon nitride for enhanced electrochemical sensing of insecticide fenitrothion in environmental samples: An experimental study with the theoretical elucidation of redox events. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 909:168483. [PMID: 37977380 DOI: 10.1016/j.scitotenv.2023.168483] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 10/18/2023] [Accepted: 11/09/2023] [Indexed: 11/19/2023]
Abstract
In the present work, a nanocomposite, based on embedding Co-doped CeO2 nanoparticles into graphitic carbon nitride (g-C3N4), was applied to functionalize commercial glassy carbon paste. This is the first application of the electrochemical sensor, developed through the proposed procedure, in electrochemical sensing. The sensor was utilized for the electrochemical determination of organophosphate pesticide fenitrothion (FNT). Cyclic voltammetry identified reversible oxidation of FNT (oxidation at 0.18 V and reduction at 0.13 V) and additional reduction at -0.62 V vs. Ag/AgCl in HCl solution (pH = 1). Theoretical calculations were carried out to model and elucidate experimentally observed redox processes. Special attention was devoted to modeling experimental conditions, and based on the obtained results, a detailed redox mechanism of the investigated analyte was proposed. This represents the first complete and unambiguous elucidation of the FNT redox mechanism, supported by joined experimental and theoretical data. Square wave voltammetry (SWV) was utilized for quantification, whereby the FNT oxidation peak was chosen for monitoring the analyte concentration. The developed sensor provided a nanomolar detection limit (3.2 nmol L-1), a wide linear concentration range (from 0.01 to 13.7 μmol L-1), and good precision, repeatability, and selectivity towards FNT. Practical application possibility was explored by testing the sensor performance for examining tap water and apple samples. Recovery tests, conducted during the FNT-spiked sample assays, showed a great application capability of the developed sensor for real-time monitoring of FNT traces in environmental samples.
Collapse
Affiliation(s)
- Slađana Đurđić
- University of Belgrade - Faculty of Chemistry, Studenstki trg 12-16, 11000 Belgrade, Serbia; Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 812 37 Bratislava, Slovak Republic.
| | - Filip Vlahović
- Scientific Institution, Institute of Chemistry, Technology and Metallurgy, National Institute University of Belgrade, 11000 Belgrade, Serbia
| | - Miloš Ognjanović
- "VINČA" Institute of Nuclear Sciences, University of Belgrade, National Institute of the Republic of Serbia, Belgrade, Serbia
| | - Pavol Gemeiner
- Department of Graphic Arts Technology and Applied Photochemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 812 37 Bratislava, Slovakia
| | - Olha Sarakhman
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 812 37 Bratislava, Slovak Republic
| | - Vesna Stanković
- Scientific Institution, Institute of Chemistry, Technology and Metallurgy, National Institute University of Belgrade, 11000 Belgrade, Serbia
| | - Jelena Mutić
- University of Belgrade - Faculty of Chemistry, Studenstki trg 12-16, 11000 Belgrade, Serbia
| | - Dalibor Stanković
- University of Belgrade - Faculty of Chemistry, Studenstki trg 12-16, 11000 Belgrade, Serbia; "VINČA" Institute of Nuclear Sciences, University of Belgrade, National Institute of the Republic of Serbia, Belgrade, Serbia
| | - Ľubomír Švorc
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinského 9, 812 37 Bratislava, Slovak Republic
| |
Collapse
|
4
|
Centane S, Mgidlana S, Openda Y, Nyokong T. Single vs sandwich aptamers: Towards the detection of human epidermal growth factor receptor 2 using composites of phthalocyanine and nanoparticles. Bioelectrochemistry 2023; 153:108496. [PMID: 37392577 DOI: 10.1016/j.bioelechem.2023.108496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 06/20/2023] [Accepted: 06/23/2023] [Indexed: 07/03/2023]
Abstract
The superiority of the sandwich over a single aptamer based aptasensor assay for the detection of the human epidermal growth factor receptor 2 (HER2) is demonstrated for the first time. Cobalt tris-3,5 dimethoxy-phenoxy pyridine (5) oxy (2)- carboxylic acid phthalocyanine (CoMPhPyCPc) and sulphur/nitrogen doped graphene quantum dots (SNGQDs) and cerium oxide nanoparticles (CeO2NPs) nanocomposite (SNGQDs@CeO2NPs) were used for electrode modification of glassy carbon electrode (GCE) both individually and combined to form the substrates: GCE/SNGQDs@CeO2NPs, GCE/CoMPhPyCPc and GCE/SNGQDs@CeO2NPs/CoMPhPyCPc. The designed substrates were used as immobilization platforms for the amino functionalized HB5 aptamer for the development of both single and sandwich aptasensor assays. A novel bioconjugate, made of the HB5 aptamer and nanocomposite (HB5-SNGQDs@CeO2NPs) was fabricated, and characterized using ultra-violet/visible, Fourier transform infrared, and Raman spectroscopies as well as scanning electron microscopy. HB5-SNGQDs@CeO2NPs was applied as a secondary aptamer in the design of novel sandwich assays towards the electrochemical detection of HER2. The performance of the designed aptasensors were evaluated using electrochemical impedance spectroscopy. The sandwich assay gave low limit of detection of 0.00088 pg/mL, high sensitivity of 773925 Ω pg-1mL, showed stability, and good precision in real samples towards HER2 detection.
Collapse
Affiliation(s)
- Sixolile Centane
- Institute of Nanotechnology Innovation, Rhodes University, Makhanda 6140, South Africa
| | - Sithi Mgidlana
- Institute of Nanotechnology Innovation, Rhodes University, Makhanda 6140, South Africa
| | - Yolande Openda
- Institute of Nanotechnology Innovation, Rhodes University, Makhanda 6140, South Africa
| | - Tebello Nyokong
- Institute of Nanotechnology Innovation, Rhodes University, Makhanda 6140, South Africa.
| |
Collapse
|
5
|
Negahdary M, Angnes L. Recent advances in electrochemical nanomaterial-based aptasensors for the detection of cancer biomarkers. Talanta 2023; 259:124548. [PMID: 37062088 DOI: 10.1016/j.talanta.2023.124548] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 04/18/2023]
Abstract
New technologies have provided suitable tools for rapid diagnosis of cancer which can reduce treatment costs and even increase patients' survival rates. Recently, the development of electrochemical aptamer-based nanobiosensors has raised great hopes for early, sensitive, selective, and low-cost cancer diagnosis. Here, we reviewed the flagged recent research (2021-2023) developed as a series of biosensors equipped with nanomaterials and aptamer sequences (nanoaptasensors) to diagnose/prognosis of various types of cancers. Equipping these aptasensors with nanomaterials and using advanced biomolecular technologies have provided specified biosensing interfaces for more optimal and reliable detection of cancer biomarkers. The primary intention of this review was to present and categorize the latest innovations used in the design of these diagnostic tools, including the hottest surface modifications and assembly of sensing bioplatforms considering diagnostic mechanisms. The main classification is based on applying various nanomaterials and sub-classifications considered based on the type of analyte and other vital features. This review may help design subsequent electrochemical aptasensors. Likewise, the up-to-date status, remaining limitations, and possible paths for translating aptasensors to clinical cancer assay tools can be clarified.
Collapse
Affiliation(s)
- Masoud Negahdary
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes, 748, São Paulo, 05508-000, Brazil.
| | - Lúcio Angnes
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes, 748, São Paulo, 05508-000, Brazil.
| |
Collapse
|
6
|
Theyagarajan K, Kim YJ. Recent Developments in the Design and Fabrication of Electrochemical Biosensors Using Functional Materials and Molecules. BIOSENSORS 2023; 13:bios13040424. [PMID: 37185499 PMCID: PMC10135976 DOI: 10.3390/bios13040424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/21/2023] [Accepted: 03/24/2023] [Indexed: 05/17/2023]
Abstract
Electrochemical biosensors are superior technologies that are used to detect or sense biologically and environmentally significant analytes in a laboratory environment, or even in the form of portable handheld or wearable electronics. Recently, imprinted and implantable biosensors are emerging as point-of-care devices, which monitor the target analytes in a continuous environment and alert the intended users to anomalies. The stability and performance of the developed biosensor depend on the nature and properties of the electrode material or the platform on which the biosensor is constructed. Therefore, the biosensor platform plays an integral role in the effectiveness of the developed biosensor. Enormous effort has been dedicated to the rational design of the electrode material and to fabrication strategies for improving the performance of developed biosensors. Every year, in the search for multifarious electrode materials, thousands of new biosensor platforms are reported. Moreover, in order to construct an effectual biosensor, the researcher should familiarize themself with the sensible strategies behind electrode fabrication. Thus, we intend to shed light on various strategies and methodologies utilized in the design and fabrication of electrochemical biosensors that facilitate sensitive and selective detection of significant analytes. Furthermore, this review highlights the advantages of various electrode materials and the correlation between immobilized biomolecules and modified surfaces.
Collapse
Affiliation(s)
- K Theyagarajan
- Department of Electronic Engineering, Gachon University, Seongnam 13120, Republic of Korea
| | - Young-Joon Kim
- Department of Electronic Engineering, Gachon University, Seongnam 13120, Republic of Korea
| |
Collapse
|
7
|
An ultrasensitive dual-signal ratio electrochemical aptamer biosensor for the detection of HER2. Colloids Surf B Biointerfaces 2023; 222:113118. [PMID: 36586239 DOI: 10.1016/j.colsurfb.2022.113118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 12/14/2022] [Accepted: 12/24/2022] [Indexed: 12/27/2022]
Abstract
Electrochemical ratiometric biosensors have received attention from researchers because of their self-calibration capability, which can improve the accuracy of detection. In the present study, a ratiometric dual signal electrochemical aptamer biosensor based on ZIF-67 @polydopamine (PDA) nanocomposite and Cu/UiO-66 @ 3, 3', 5, 5'-tetramethylbenzidine (TMB) nanocomposite was fabricated for the detection of breast cancer biomarker- human epidermal growth factor receptor 2 (HER2). PDA was chosen as the electroactive material with electrochemical redox activity and ZIF-67 with a high specific surface area, forming the ZIF-67 @PDA+Apt as the nanoprobe for capturing HER2 in this paper. Cu/UiO-66 is a bimetallic compound with high stability, specific surface area, and strong adsorption onto aptamer chains, and the Cu/UiO-66 @TMB+Apt nanocomposite was used as a probe for signal labeling. In the presence of HER2, the capture of HER2 by the ZIF-67 @PDA+Apt probe results in a weakening of the conductivity of the electrode, however, by attenuating the electrochemical signal from the PDA, altering the probe-Cu/UiO-66 @TMB+Apt signaling will result in the enhancement of the TMB electrochemical signal. With a sensitive detection of HER2 biomarkers in as little as 30 min with the detection range of 0.75-40 pg/mL and a limit of detection as low as 44.8 fg/mL. Dual signal ratio biosensors have a low limit of detection, short detection time, which can accurately detect targets in complex biological samples, which has important theoretical importance.
Collapse
|
8
|
Centane S, Nyokong T. Co phthalocyanine mediated electrochemical detection of the HER2 in the presence of Au and CeO2 nanoparticles and graphene quantum dots. Bioelectrochemistry 2023; 149:108301. [DOI: 10.1016/j.bioelechem.2022.108301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 10/03/2022] [Accepted: 10/08/2022] [Indexed: 11/06/2022]
|