1
|
Howe A, Chen Z, Golobish K, Miduri VR, Liu D, Valencia D, McGaughey M, Szabo E, Franke M, Nieuwoudt S. Removal Forces of a Helical Microwire Structure Electrode. Bioengineering (Basel) 2024; 11:611. [PMID: 38927847 PMCID: PMC11200423 DOI: 10.3390/bioengineering11060611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 05/22/2024] [Accepted: 06/11/2024] [Indexed: 06/28/2024] Open
Abstract
(1) Background: Medical devices, especially neuromodulation devices, are often explanted for a variety of reasons. The removal process imparts significant forces on these devices, which may result in device fracture and tissue trauma. We hypothesized that a device's form factor interfacing with tissue is a major driver of the force required to remove a device, and we isolated helical and linear electrode structures as a means to study atraumatic removal. (2) Methods: Ductile linear and helical microwire structure electrodes were fabricated from either Gold (Au) or Platinum-Iridium (Pt-Ir, 90-10). Removal forces were captured from synthetic gel models and following chronic implantation in rodent and porcine models. Devices were fully implanted in the animal models, requiring a small incision (<10 mm) and removal via tissue forceps. (3) Results: Helical devices were shown to result in significantly lower maximal removal forces in both synthetic gel and rodent studies compared to their linear counterparts. Chronically (1 yr.), the maximal removal force of helical devices remained under 7.30 N, for which the Platinum-Iridium device's tensile failure force was 32.90 ± 2.09 N, resulting in a safety factor of 4.50. (4) Conclusions: An open-core helical structure that can freely elongate was shown to result in reduced removal forces both acutely and chronically.
Collapse
|
2
|
González-González MA, Conde SV, Latorre R, Thébault SC, Pratelli M, Spitzer NC, Verkhratsky A, Tremblay MÈ, Akcora CG, Hernández-Reynoso AG, Ecker M, Coates J, Vincent KL, Ma B. Bioelectronic Medicine: a multidisciplinary roadmap from biophysics to precision therapies. Front Integr Neurosci 2024; 18:1321872. [PMID: 38440417 PMCID: PMC10911101 DOI: 10.3389/fnint.2024.1321872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Accepted: 01/10/2024] [Indexed: 03/06/2024] Open
Abstract
Bioelectronic Medicine stands as an emerging field that rapidly evolves and offers distinctive clinical benefits, alongside unique challenges. It consists of the modulation of the nervous system by precise delivery of electrical current for the treatment of clinical conditions, such as post-stroke movement recovery or drug-resistant disorders. The unquestionable clinical impact of Bioelectronic Medicine is underscored by the successful translation to humans in the last decades, and the long list of preclinical studies. Given the emergency of accelerating the progress in new neuromodulation treatments (i.e., drug-resistant hypertension, autoimmune and degenerative diseases), collaboration between multiple fields is imperative. This work intends to foster multidisciplinary work and bring together different fields to provide the fundamental basis underlying Bioelectronic Medicine. In this review we will go from the biophysics of the cell membrane, which we consider the inner core of neuromodulation, to patient care. We will discuss the recently discovered mechanism of neurotransmission switching and how it will impact neuromodulation design, and we will provide an update on neuronal and glial basis in health and disease. The advances in biomedical technology have facilitated the collection of large amounts of data, thereby introducing new challenges in data analysis. We will discuss the current approaches and challenges in high throughput data analysis, encompassing big data, networks, artificial intelligence, and internet of things. Emphasis will be placed on understanding the electrochemical properties of neural interfaces, along with the integration of biocompatible and reliable materials and compliance with biomedical regulations for translational applications. Preclinical validation is foundational to the translational process, and we will discuss the critical aspects of such animal studies. Finally, we will focus on the patient point-of-care and challenges in neuromodulation as the ultimate goal of bioelectronic medicine. This review is a call to scientists from different fields to work together with a common endeavor: accelerate the decoding and modulation of the nervous system in a new era of therapeutic possibilities.
Collapse
Affiliation(s)
- María Alejandra González-González
- Jan and Dan Duncan Neurological Research Institute, Texas Children’s Hospital, Houston, TX, United States
- Department of Pediatric Neurology, Baylor College of Medicine, Houston, TX, United States
| | - Silvia V. Conde
- iNOVA4Health, NOVA Medical School, Faculdade de Ciências Médicas, NOVA University, Lisbon, Portugal
| | - Ramon Latorre
- Centro Interdisciplinario de Neurociencia de Valparaíso, Facultad de Ciencias, Universidad de Valparaíso, Valparaíso, Chile
| | - Stéphanie C. Thébault
- Laboratorio de Investigación Traslacional en salud visual (D-13), Instituto de Neurobiología, Universidad Nacional Autónoma de México (UNAM), Querétaro, Mexico
| | - Marta Pratelli
- Neurobiology Department, Kavli Institute for Brain and Mind, UC San Diego, La Jolla, CA, United States
| | - Nicholas C. Spitzer
- Neurobiology Department, Kavli Institute for Brain and Mind, UC San Diego, La Jolla, CA, United States
| | - Alexei Verkhratsky
- Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
- Achucarro Centre for Neuroscience, IKERBASQUE, Basque Foundation for Science, Bilbao, Spain
- Department of Forensic Analytical Toxicology, School of Forensic Medicine, China Medical University, Shenyang, China
- International Collaborative Center on Big Science Plan for Purinergic Signaling, Chengdu University of Traditional Chinese Medicine, Chengdu, China
- Department of Stem Cell Biology, State Research Institute Centre for Innovative Medicine, Vilnius, Lithuania
| | - Marie-Ève Tremblay
- Division of Medical Sciences, University of Victoria, Victoria, BC, Canada
- Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada
- Department of Molecular Medicine, Université Laval, Québec City, QC, Canada
- Department of Biochemistry and Molecular Biology, The University of British Columbia, Vancouver, BC, Canada
| | - Cuneyt G. Akcora
- Department of Computer Science, University of Central Florida, Orlando, FL, United States
| | | | - Melanie Ecker
- Department of Biomedical Engineering, University of North Texas, Denton, TX, United States
| | | | - Kathleen L. Vincent
- Department of Obstetrics and Gynecology, University of Texas Medical Branch, Galveston, TX, United States
| | - Brandy Ma
- Stanley H. Appel Department of Neurology, Houston Methodist Hospital, Houston, TX, United States
| |
Collapse
|
3
|
Koschinski L, Lenyk B, Jung M, Lenzi I, Kampa B, Mayer D, Offenhäusser A, Musall S, Rincón Montes V. Validation of transparent and flexible neural implants for simultaneous electrophysiology, functional imaging, and optogenetics. J Mater Chem B 2023; 11:9639-9657. [PMID: 37610228 DOI: 10.1039/d3tb01191g] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
The combination of electrophysiology and neuroimaging methods allows the simultaneous measurement of electrical activity signals with calcium dynamics from single neurons to neuronal networks across distinct brain regions in vivo. While traditional electrophysiological techniques are limited by photo-induced artefacts and optical occlusion for neuroimaging, different types of transparent neural implants have been proposed to resolve these issues. However, reproducing proposed solutions is often challenging and it remains unclear which approach offers the best properties for long-term chronic multimodal recordings. We therefore created a streamlined fabrication process to produce, and directly compare, two types of transparent surface micro-electrocorticography (μECoG) implants: nano-mesh gold structures (m-μECoGs) versus a combination of solid gold interconnects and PEDOT:PSS-based electrodes (pp-μECoGs). Both implants allowed simultaneous multimodal recordings but pp-μECoGs offered the best overall electrical, electrochemical, and optical properties with negligible photo-induced artefacts to light wavelengths of interest. Showing functional chronic stability for up to four months, pp-μECoGs also allowed the simultaneous functional mapping of electrical and calcium neural signals upon visual and tactile stimuli during widefield imaging. Moreover, recordings during two-photon imaging showed no visible signal attenuation and enabled the correlation of network dynamics across brain regions to individual neurons located directly below the transparent electrical contacts.
Collapse
Affiliation(s)
- Lina Koschinski
- Institute of Biological Information Processing (IBI-3) - Bioelectronics, Forschungszentrum, Jülich, Germany.
- Helmholtz Nano Facility (HNF), Forschungszentrum, Jülich, Germany
- RWTH Aachen University, Germany
| | - Bohdan Lenyk
- Institute of Biological Information Processing (IBI-3) - Bioelectronics, Forschungszentrum, Jülich, Germany.
| | - Marie Jung
- Institute of Biological Information Processing (IBI-3) - Bioelectronics, Forschungszentrum, Jülich, Germany.
- RWTH Aachen University, Germany
| | - Irene Lenzi
- Institute of Biological Information Processing (IBI-3) - Bioelectronics, Forschungszentrum, Jülich, Germany.
- RWTH Aachen University, Germany
| | - Björn Kampa
- RWTH Aachen University, Germany
- JARA BRAIN Institute of Neuroscience and Medicine (INM-10), Forschungszentrum, Jülich, Germany
| | - Dirk Mayer
- Institute of Biological Information Processing (IBI-3) - Bioelectronics, Forschungszentrum, Jülich, Germany.
| | - Andreas Offenhäusser
- Institute of Biological Information Processing (IBI-3) - Bioelectronics, Forschungszentrum, Jülich, Germany.
| | - Simon Musall
- Institute of Biological Information Processing (IBI-3) - Bioelectronics, Forschungszentrum, Jülich, Germany.
- RWTH Aachen University, Germany
- University of Bonn, Faculty of Medicine, Institute of Experimental Epileptology and Cognition Research, Germany
- University Hospital Bonn, Germany
| | - Viviana Rincón Montes
- Institute of Biological Information Processing (IBI-3) - Bioelectronics, Forschungszentrum, Jülich, Germany.
| |
Collapse
|
4
|
Castagnola E, Robbins EM, Krahe DD, Wu B, Pwint MY, Cao Q, Cui XT. Stable in-vivo electrochemical sensing of tonic serotonin levels using PEDOT/CNT-coated glassy carbon flexible microelectrode arrays. Biosens Bioelectron 2023; 230:115242. [PMID: 36989659 PMCID: PMC10101938 DOI: 10.1016/j.bios.2023.115242] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 03/13/2023] [Accepted: 03/19/2023] [Indexed: 03/29/2023]
Abstract
Chronic sampling of tonic serotonin (5-hydroxytryptamine, 5-HT) concentrations in the brain is critical for tracking neurological disease development and the time course of pharmacological treatments. Despite their value, in vivo chronic multi-site measurements of tonic 5-HT have not been reported. To fill this technological gap, we batch-fabricated implantable glassy carbon (GC) microelectrode arrays (MEAs) onto a flexible SU-8 substrate to provide an electrochemically stable and biocompatible device/tissue interface. To achieve detection of tonic 5-HT concentrations, we applied a poly(3,4-ethylenedioxythiophene)/carbon nanotube (PEDOT/CNT) electrode coating and optimized a square wave voltammetry (SWV) waveform for selective 5-HT measurement. In vitro, the PEDOT/CNT-coated GC microelectrodes achieved high sensitivity to 5-HT, good fouling resistance, and excellent selectivity against the most common neurochemical interferents. In vivo, our PEDOT/CNT-coated GC MEAs successfully detected basal 5-HT concentrations at different locations within the CA2 region of the hippocampus of both anesthetized and awake mice. Furthermore, the PEDOT/CNT-coated MEAs were able to detect tonic 5-HT in the mouse hippocampus for one week after implantation. Histology reveals that the flexible GC MEA implants caused less tissue damage and reduced inflammatory response in the hippocampus compared to commercially available stiff silicon probes. To the best of our knowledge, this PEDOT/CNT-coated GC MEA is the first implantable, flexible sensor capable of chronic in vivo multi-site sensing of tonic 5-HT.
Collapse
Affiliation(s)
- Elisa Castagnola
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA; Department of Biomedical Engineering, Louisiana Tech University, Ruston, LA, 818 Nelson Ave, 71272, USA
| | - Elaine M Robbins
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA
| | - Daniela D Krahe
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA
| | - Bingchen Wu
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA; Center for Neural Basis of Cognition, University of Pittsburgh, 4400 Fifth Ave, PA 15213, Pittsburgh, PA, 15261, USA
| | - May Yoon Pwint
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA; Center for Neural Basis of Cognition, University of Pittsburgh, 4400 Fifth Ave, PA 15213, Pittsburgh, PA, 15261, USA
| | - Qun Cao
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA
| | - Xinyan Tracy Cui
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260, Pittsburgh, PA, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, 450 Technology Drive, Pittsburgh, PA, 15219-3110, USA; Center for Neural Basis of Cognition, University of Pittsburgh, 4400 Fifth Ave, PA 15213, Pittsburgh, PA, 15261, USA.
| |
Collapse
|
5
|
Abstract
Soft robotics facilitates the deployment of large radial electrode arrays on the brain cortex through small craniotomies.
Collapse
Affiliation(s)
- Maria Asplund
- Department of Microtechnology and Nanoscience, Chalmers University of Technology, Gothenburg, Sweden
- Department of Health, Education and Technology, Luleå University of Technology, Luleå, Sweden
| |
Collapse
|
6
|
Stieglitz T, Gueli C, Martens J, Floto N, Eickenscheidt M, Sporer M, Ortmanns M. Highly conformable chip-in-foil implants for neural applications. MICROSYSTEMS & NANOENGINEERING 2023; 9:54. [PMID: 37180455 PMCID: PMC10167239 DOI: 10.1038/s41378-023-00527-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 02/26/2023] [Accepted: 03/24/2023] [Indexed: 05/16/2023]
Abstract
Demands for neural interfaces around functionality, high spatial resolution, and longevity have recently increased. These requirements can be met with sophisticated silicon-based integrated circuits. Embedding miniaturized dice in flexible polymer substrates significantly improves their adaptation to the mechanical environment in the body, thus improving the systems' structural biocompatibility and ability to cover larger areas of the brain. This work addresses the main challenges in developing a hybrid chip-in-foil neural implant. Assessments considered (1) the mechanical compliance to the recipient tissue that allows a long-term application and (2) the suitable design that allows the implant's scaling and modular adaptation of chip arrangement. Finite element model studies were performed to identify design rules regarding die geometry, interconnect routing, and positions for contact pads on dice. Providing edge fillets in the die base shape proved an effective measure to improve die-substrate integrity and increase the area available for contact pads. Furthermore, routing of interconnects in the immediate vicinity of die corners should be avoided, as the substrate in these areas is prone to mechanical stress concentration. Contact pads on dice should be placed with a clearance from the die rim to avoid delamination when the implant conforms to a curvilinear body. A microfabrication process was developed to transfer, align, and electrically interconnect multiple dice into conformable polyimide-based substrates. The process enabled arbitrary die shape and size over independent target positions on the conformable substrate based on the die position on the fabrication wafer.
Collapse
Affiliation(s)
- Thomas Stieglitz
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering - IMTEK, University of Freiburg, D-79110 Freiburg, Germany
- BrainLinks-BrainTools// IMBIT, University of Freiburg, D-79110 Freiburg, Germany
| | - Calogero Gueli
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering - IMTEK, University of Freiburg, D-79110 Freiburg, Germany
| | - Julien Martens
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering - IMTEK, University of Freiburg, D-79110 Freiburg, Germany
- BrainLinks-BrainTools// IMBIT, University of Freiburg, D-79110 Freiburg, Germany
| | - Niklas Floto
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering - IMTEK, University of Freiburg, D-79110 Freiburg, Germany
- BrainLinks-BrainTools// IMBIT, University of Freiburg, D-79110 Freiburg, Germany
| | - Max Eickenscheidt
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering - IMTEK, University of Freiburg, D-79110 Freiburg, Germany
| | - Markus Sporer
- Institute of Microelectronics, University of Ulm, D-89081 Ulm, Germany
| | - Maurits Ortmanns
- Institute of Microelectronics, University of Ulm, D-89081 Ulm, Germany
| |
Collapse
|
7
|
Böhler C, Vomero M, Soula M, Vöröslakos M, Porto Cruz M, Liljemalm R, Buzsaki G, Stieglitz T, Asplund M. Multilayer Arrays for Neurotechnology Applications (MANTA): Chronically Stable Thin-Film Intracortical Implants. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2207576. [PMID: 36935361 DOI: 10.1002/advs.202207576] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 02/07/2023] [Indexed: 05/18/2023]
Abstract
Flexible implantable neurointerfaces show great promise in addressing one of the major challenges of implantable neurotechnology, namely the loss of signal connected to unfavorable probe tissue interaction. The authors here show how multilayer polyimide probes allow high-density intracortical recordings to be combined with a reliable long-term stable tissue interface, thereby progressing toward chronic stability of implantable neurotechnology. The probes could record 10-60 single units over 5 months with a consistent peak-to-peak voltage at dimensions that ensure robust handling and insulation longevity. Probes that remain in intimate contact with the signaling tissue over months to years are a game changer for neuroscience and, importantly, open up for broader clinical translation of systems relying on neurotechnology to interface the human brain.
Collapse
Affiliation(s)
- Christian Böhler
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany
- BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany
| | - Maria Vomero
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany
- BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany
| | - Marisol Soula
- Neuroscience Institute, Langone Medical Center, New York University, New York, 10016, USA
| | - Mihály Vöröslakos
- Neuroscience Institute, Langone Medical Center, New York University, New York, 10016, USA
| | - Maria Porto Cruz
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany
- BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany
| | - Rickard Liljemalm
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany
| | - György Buzsaki
- Neuroscience Institute, Langone Medical Center, New York University, New York, 10016, USA
- Department of Physiology and Neuroscience, Langone Medical Center, New York University, New York, 10016, USA
- Department of Neurology, Langone Medical Center, New York University, New York, 10016, USA
| | - Thomas Stieglitz
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany
- BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany
- Bernstein Center Freiburg, University of Freiburg, 79110, Freiburg, Germany
| | - Maria Asplund
- Department of Microsystems Engineering (IMTEK), University of Freiburg, 79110, Freiburg, Germany
- BrainLinks-BrainTools Center, University of Freiburg, 79110, Freiburg, Germany
- Department of Microtechnology and Nanoscience, Chalmers University of Technology, Gothenburg, SE-41296, Sweden
- Division of Nursing and Medical Technology, Luleå University of Technology, Luleå, 97187, Sweden
- Freiburg Institute for Advanced Studies (FRIAS), University of Freiburg, 79110, Freiburg, Germany
| |
Collapse
|
8
|
Hu Z, Niu Q, Hsiao BS, Yao X, Zhang Y. Bioactive polymer-enabled conformal neural interface and its application strategies. MATERIALS HORIZONS 2023; 10:808-828. [PMID: 36597872 DOI: 10.1039/d2mh01125e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Neural interface is a powerful tool to control the varying neuron activities in the brain, where the performance can directly affect the quality of recording neural signals and the reliability of in vivo connection between the brain and external equipment. Recent advances in bioelectronic innovation have provided promising pathways to fabricate flexible electrodes by integrating electrodes on bioactive polymer substrates. These bioactive polymer-based electrodes can enable the conformal contact with irregular tissue and result in low inflammation when compared to conventional rigid inorganic electrodes. In this review, we focus on the use of silk fibroin and cellulose biopolymers as well as certain synthetic polymers to offer the desired flexibility for constructing electrode substrates for a conformal neural interface. First, the development of a neural interface is reviewed, and the signal recording methods and tissue response features of the implanted electrodes are discussed in terms of biocompatibility and flexibility of corresponding neural interfaces. Following this, the material selection, structure design and integration of conformal neural interfaces accompanied by their effective applications are described. Finally, we offer our perspectives on the evolution of desired bioactive polymer-enabled neural interfaces, regarding the biocompatibility, electrical properties and mechanical softness.
Collapse
Affiliation(s)
- Zhanao Hu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, People's Republic of China.
| | - Qianqian Niu
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, People's Republic of China.
| | - Benjamin S Hsiao
- Department of Chemistry, Stony Brook University, Stony Brook, New York, 11794-3400, USA
| | - Xiang Yao
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, People's Republic of China.
| | - Yaopeng Zhang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, Shanghai Engineering Research Center of Nano-Biomaterials and Regenerative Medicine, College of Materials Science and Engineering, Donghua University, Shanghai, 201620, People's Republic of China.
| |
Collapse
|
9
|
Borda E, Medagoda DI, Airaghi Leccardi MJI, Zollinger EG, Ghezzi D. Conformable neural interface based on off-stoichiometry thiol-ene-epoxy thermosets. Biomaterials 2023; 293:121979. [PMID: 36586146 DOI: 10.1016/j.biomaterials.2022.121979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 11/29/2022] [Accepted: 12/21/2022] [Indexed: 12/28/2022]
Abstract
Off-stoichiometry thiol-ene-epoxy (OSTE+) thermosets show low permeability to gases and little absorption of dissolved molecules, allow direct low-temperature dry bonding without surface treatments, have a low Young's modulus, and can be manufactured via UV polymerisation. For these reasons, OSTE+ thermosets have recently gained attention for the rapid prototyping of microfluidic chips. Moreover, their compatibility with standard clean-room processes and outstanding mechanical properties make OSTE+ an excellent candidate as a novel material for neural implants. Here we exploit OSTE+ to manufacture a conformable multilayer micro-electrocorticography array with 16 platinum electrodes coated with platinum black. The mechanical properties allow conformability to curved surfaces such as the brain. The low permeability and strong adhesion between layers improve the stability of the device. Acute experiments in mice show the multimodal capacity of the array to record and stimulate the neural tissue by smoothly conforming to the mouse cortex. Devices are not cytotoxic, and immunohistochemistry stainings reveal only modest foreign body reaction after two and six weeks of chronic implantation. This work introduces OSTE+ as a promising material for implantable neural interfaces.
Collapse
Affiliation(s)
- Eleonora Borda
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics and Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Switzerland
| | - Danashi Imani Medagoda
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics and Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Switzerland
| | - Marta Jole Ildelfonsa Airaghi Leccardi
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics and Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Switzerland
| | - Elodie Geneviève Zollinger
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics and Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Switzerland
| | - Diego Ghezzi
- Medtronic Chair in Neuroengineering, Center for Neuroprosthetics and Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne, Switzerland.
| |
Collapse
|
10
|
Castagnola E, Robbins EM, Krahe D, Wu B, Pwint MY, Cao Q, Cui XT. Implantable flexible multielectrode arrays for multi-site sensing of serotonin tonic levels. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.01.17.524488. [PMID: 36711655 PMCID: PMC9882191 DOI: 10.1101/2023.01.17.524488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Real-time multi-channel measurements of tonic serotonin (5-hydroxytryptamine, 5-HT) concentrations across different brain regions are of utmost importance to the understanding of 5-HT’s role in anxiety, depression, and impulse control disorders, which will improve the diagnosis and treatment of these neuropsychiatric illnesses. Chronic sampling of 5-HT is critical in tracking disease development as well as the time course of pharmacological treatments. Despite their value, in vivo chronic multi-site measurements of 5-HT have not been reported. To fill this technological gap, we batch fabricated implantable glassy carbon (GC) microelectrode arrays (MEAs) on a flexible SU-8 substrate to provide an electrochemically stable and biocompatible device/tissue interface. Then, to achieve multi-site detection of tonic 5-HT concentrations, we incorporated the poly(3,4-ethylenedioxythiophene)/functionalized carbon nanotube (PEDOT/CNT) coating on the GC microelectrodes in combination with a new square wave voltammetry (SWV) approach, optimized for selective 5-HT measurement. In vitro , the PEDOT/CNT coated GC microelectrodes achieved high sensitivity towards 5-HT, good fouling resistance in the presence of 5-HT, and excellent selectivity towards the most common neurochemical interferents. In vivo , our PEDOT/CNT-coated GC MEAs were able to successfully detect basal 5-HT concentrations at different locations of the CA2 hippocampal region of mice in both anesthetized and awake head-fixed conditions. Furthermore, the implanted PEDOT/CNT-coated MEA achieved stable detection of tonic 5-HT concentrations for one week. Finally, histology data in the hippocampus shows reduced tissue damage and inflammatory responses compared to stiff silicon probes. To the best of our knowledge, this PEDOT/CNT-coated GC MEA is the first implantable flexible multisite sensor capable of chronic in vivo multi-site sensing of tonic 5-HT. This implantable MEA can be custom-designed according to specific brain region of interests and research questions, with the potential to combine electrophysiology recording and multiple analyte sensing to maximize our understanding of neurochemistry. Highlights PEDOT/CNT-coated GC microelectrodes enabled sensitive and selective tonic detection of serotonin (5-HT) using a new square wave voltammetry (SWV) approach PEDOT/CNT-coated GC MEAs achieved multi-site in vivo 5-HT tonic detection for one week. Flexible MEAs lead to reduced tissue damage and inflammation compared to stiff silicon probes.
Collapse
|
11
|
Saghir S, Imenes K, Schiavone G. Integration of hydrogels in microfabrication processes for bioelectronic medicine: Progress and outlook. Front Bioeng Biotechnol 2023; 11:1150147. [PMID: 37034261 PMCID: PMC10079906 DOI: 10.3389/fbioe.2023.1150147] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 03/10/2023] [Indexed: 04/11/2023] Open
Abstract
Recent research aiming at the development of electroceuticals for the treatment of medical conditions such as degenerative diseases, cardiac arrhythmia and chronic pain, has given rise to microfabricated implanted bioelectronic devices capable of interacting with host biological tissues in synergistic modalities. Owing to their multimodal affinity to biological tissues, hydrogels have emerged as promising interface materials for bioelectronic devices. Here, we review the state-of-the-art and forefront in the techniques used by research groups for the integration of hydrogels into the microfabrication processes of bioelectronic devices, and present the manufacturability challenges to unlock their further clinical deployment.
Collapse
|
12
|
Ji B, Wang T, Li M, Shi L, You X, Sun F, Luan H. Localized Surface Hydrophilicity Tailoring of Polyimide Film for Flexible Electronics Manufacturing Using an Atmospheric Pressure Ar/H 2O Microplasma Jet. MICROMACHINES 2022; 13:1853. [PMID: 36363874 PMCID: PMC9696727 DOI: 10.3390/mi13111853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 10/26/2022] [Accepted: 10/26/2022] [Indexed: 06/16/2023]
Abstract
The poor hydrophilicity of polyimide (PI) films limits their applications in flexible electronics, such as in wearable and implantable bio-MEMS devices. In this paper, an atmospheric pressure Ar/H2O microplasma jet (μAPPJ) with a nozzle diameter of 100 μm was utilized to site-selectively tune the surface hydrophilicity of a PI film. The electrical and optical characteristics of the μAPPJ were firstly investigated, and the results showed that multi-spikes occurred during the plasma discharge and that diverse reactive species, such as O atoms and OH radicals, were generated in the plasma plume. The physical and chemical properties of pristine and microplasma-modified PI surfaces were characterized by the water contact angle (WCA), atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). The wettability of the PI surface was significantly enhanced after microplasma modification, and the WCA could be adjusted by varying the applied voltage, water vapor content, plasma treatment time and storage time. The AFM images indicated that the surface roughness increased after the plasma treatment, which partially contributed to an improvement in the surface hydrophilicity. The XPS results showed a reduction in the C content and an increase in the O content, and abundant hydrophilic polar oxygen-containing functional groups were also grafted onto the PI film surface. Finally, the interaction mechanism between the PI molecular chains and the microplasma is discussed. The breaking of C-N and C-O bonds and the grafting of OH radicals were the key pathways to dominate the reaction process.
Collapse
Affiliation(s)
- Bowen Ji
- Unmanned System Research Institute, Northwestern Polytechnical University, Xi’an 710072, China
- Collaborative Innovation Center, Northwestern Polytechnical University, Shanghai 201108, China
| | - Tao Wang
- School of Mechanical Engineering, Anhui University of Technology, Ma’anshan 243032, China
| | - Meng Li
- School of Mechanical Engineering, Anhui University of Technology, Ma’anshan 243032, China
| | - Liping Shi
- School of Mechanical Engineering, Anhui University of Technology, Ma’anshan 243032, China
| | - Xiaoli You
- Unmanned System Research Institute, Northwestern Polytechnical University, Xi’an 710072, China
- Collaborative Innovation Center, Northwestern Polytechnical University, Shanghai 201108, China
| | - Fanqi Sun
- Unmanned System Research Institute, Northwestern Polytechnical University, Xi’an 710072, China
- Collaborative Innovation Center, Northwestern Polytechnical University, Shanghai 201108, China
| | - Haiwen Luan
- Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60201, USA
| |
Collapse
|
13
|
Harland B, Aqrawe Z, Vomero M, Boehler C, Cheah E, Raos B, Asplund M, O'Carroll SJ, Svirskis D. A Subdural Bioelectronic Implant to Record Electrical Activity from the Spinal Cord in Freely Moving Rats. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2105913. [PMID: 35499184 PMCID: PMC9284137 DOI: 10.1002/advs.202105913] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 04/06/2022] [Indexed: 05/28/2023]
Abstract
Bioelectronic devices have found use at the interface with neural tissue to investigate and treat nervous system disorders. Here, the development and characterization of a very thin flexible bioelectronic implant inserted along the thoracic spinal cord in rats directly in contact with and conformable to the dorsal surface of the spinal cord are presented. There is no negative impact on hind-limb functionality nor any change in the volume or shape of the spinal cord. The bioelectronic implant is maintained in rats for a period of 12 weeks. The first subdural recordings of spinal cord activity in freely moving animals are presented; rats are plugged in via a recording cable and allowed to freely behave and move around on a raised platform. Recordings contained multiple distinct voltage waveforms spatially localize to individual electrodes. This device has great potential to monitor electrical signaling in the spinal cord after an injury and in the future, this implant will facilitate the identification of biomarkers in spinal cord injury and recovery, while enabling the delivery of localized electroceutical and chemical treatments.
Collapse
Affiliation(s)
- Bruce Harland
- School of PharmacyThe University of AucklandAuckland1023New Zealand
| | - Zaid Aqrawe
- School of PharmacyThe University of AucklandAuckland1023New Zealand
| | - Maria Vomero
- Department of Microsystems Engineering (IMTEK)BrainLinks‐BrainTools CenterUniversity of FreiburgFreiburg79110Germany
| | - Christian Boehler
- Department of Microsystems Engineering (IMTEK)BrainLinks‐BrainTools CenterUniversity of FreiburgFreiburg79110Germany
| | - Ernest Cheah
- School of PharmacyThe University of AucklandAuckland1023New Zealand
| | - Brad Raos
- School of PharmacyThe University of AucklandAuckland1023New Zealand
| | - Maria Asplund
- Department of Microsystems Engineering (IMTEK)BrainLinks‐BrainTools Center and Freiburg Institute for Advanced Studies (FRIAS)University of FreiburgFreiburg79110Germany
- Division of Nursing and Medical TechnologyLuleå University of TechnologyLuleå971 87Sweden
| | - Simon J. O'Carroll
- Department of Anatomy & Medical ImagingSchool of Medical SciencesThe University of AucklandAuckland1023New Zealand
| | - Darren Svirskis
- School of PharmacyThe University of AucklandAuckland1023New Zealand
| |
Collapse
|
14
|
Kaewmanee R, Wang F, Mei S, Pan Y, Yu B, Wu Z, Meesane J, Wei J. Molybdenum disulfide nanosheet/polyimide composites with improved tribological performances, surface properties, antibacterial effects and osteogenesis for facilitating osseointegration. J Mater Chem B 2022; 10:5058-5070. [PMID: 35727102 DOI: 10.1039/d2tb00776b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Polymeric biocomposites display some advantages over metal or ceramic biomaterials, and are regarded as a promising candidate for artificial joint application. Herein, molybdenum disulfide (MD) nanosheets were prepared and incorporated into polyimide (PI) to form MD/PI composites with a MD content of 20 wt% (PM20) and 40 wt% (PM40). The results revealed that incorporation of MD nanosheets obviously improved the tribological performances, surface properties (e.g., roughness, wettability and surface energy) and protein absorption of the composites, which enhanced with the increase of MD content. In addition, the composites containing MD nanosheets exhibited antibacterial effects, and the antibacterial effects of PM40 were higher than those of PM20 and PI. PM40 significantly stimulated the cellular responses of rat bone mesenchymal stem cells in vitro, which was better than PM20 and PI. Furthermore, PM40 remarkably accelerated osteogenesis and osseointegration in vivo, which was better than PM20 and PI. In summary, the MD content in composites played pivotal roles in improving not only tribological performances, surface properties, antibacterial effects and cellular response in vitro but also osteogenesis and osseointegration in vivo. As a result, PM40 with high MD content exhibited excellent osteogenic bioactivity and antibacterial effects, which would have great potential for artificial joint applications.
Collapse
Affiliation(s)
- Rames Kaewmanee
- Shanghai Key Laboratory of Advanced Polymeric Materials, East China University of Science and Technology, Shanghai, 200237, China.
| | - Fan Wang
- Shanghai Key Laboratory of Advanced Polymeric Materials, East China University of Science and Technology, Shanghai, 200237, China.
| | - Shiqi Mei
- Shanghai Key Laboratory of Advanced Polymeric Materials, East China University of Science and Technology, Shanghai, 200237, China.
| | - Yongkang Pan
- Shanghai Key Laboratory of Advanced Polymeric Materials, East China University of Science and Technology, Shanghai, 200237, China.
| | - Baoqing Yu
- Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, Shanghai, 201399, China.
| | - Zhaoying Wu
- School of Biomedical Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen, Guangdong 518107, China.
| | - Jirut Meesane
- Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand
| | - Jie Wei
- Shanghai Key Laboratory of Advanced Polymeric Materials, East China University of Science and Technology, Shanghai, 200237, China.
| |
Collapse
|
15
|
Kullmann A, Kridner D, Mertens S, Christianson M, Rosa D, Diaz-Botia CA. First Food and Drug Administration Cleared Thin-Film Electrode for Intracranial Stimulation, Recording, and Monitoring of Brain Activity—Part 1: Biocompatibility Testing. Front Neurosci 2022; 16:876877. [PMID: 35573282 PMCID: PMC9100917 DOI: 10.3389/fnins.2022.876877] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Accepted: 03/28/2022] [Indexed: 11/16/2022] Open
Abstract
Subdural strip and grid invasive electroencephalography electrodes are routinely used for surgical evaluation of patients with drug-resistant epilepsy (DRE). Although these electrodes have been in the United States market for decades (first FDA clearance 1985), their fabrication, materials, and properties have hardly changed. Existing commercially available electrodes are made of silicone, are thick (>0.5 mm), and do not optimally conform to brain convolutions. New thin-film polyimide electrodes (0.08 mm) have been manufactured to address these issues. While different thin-film electrodes are available for research use, to date, only one electrode is cleared by Food and Drug Administration (FDA) for use in clinical practice. This study describes the biocompatibility tests that led to this clearance. Biocompatibility was tested using standard methods according to International Organization for Standardization (ISO) 10993. Electrodes and appropriate control materials were bent, folded, and placed in the appropriate extraction vehicles, or implanted. The extracts were used for in vitro and in vivo tests, to assess the effects of any potential extractable and leachable materials that may be toxic to the body. In vitro studies included cytotoxicity tested in L929 cell line, genotoxicity tested using mouse lymphoma assay (MLA) and Ames assay, and hemolysis tested in rabbit whole blood samples. The results indicated that the electrodes were non-cytotoxic, non-mutagenic, non-clastogenic, and non-hemolytic. In vivo studies included sensitization tested in guinea pigs, irritation tested in rabbits, acute systemic toxicity testing in mice, pyrogenicity tested in rabbits, and a prolonged 28-day subdural implant in sheep. The results indicated that the electrodes induced no sensitization and irritation, no weight loss, and no temperature increase. Histological examination of the sheep brain tissue showed no or minimal immune cell accumulation, necrosis, neovascularization, fibrosis, and astrocyte infiltration, with no differences from the control material. In summary, biocompatibility studies indicated that these new thin-film electrodes are appropriate for human use. As a result, the electrodes were cleared by the FDA for use in clinical practice [510(k) K192764], making it the first thin-film subdural electrode to progress from research to clinic. Its readiness as a commercial product ensures availability to all patients undergoing surgical evaluation for DRE.
Collapse
|