1
|
Saini A, Yadav N, Singh B, Rana JS. An overview of biosensor advancements for detecting botulinum neurotoxins: Addressing food safety and biowarfare risks. Anal Biochem 2025; 701:115801. [PMID: 39921138 DOI: 10.1016/j.ab.2025.115801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2024] [Revised: 02/03/2025] [Accepted: 02/04/2025] [Indexed: 02/10/2025]
Abstract
Botulinum neurotoxins (BoNTs) are lethal toxins produced by bacteria Clostridium botulinum. Ingestion of BoNTs contaminated foods causes botulism which affects individual's nervous system by blocking the release of neurotransmitters causing flaccid paralysis. This review article deciphers the comprehensive account on mechanism of action of BoNTs, pathogenicity, and various innovative analytical detection techniques of BoNTs in foods. Potential misuse of BoNT as a biowarfare agent is also a major concern. Hence, for the detection of deadly BoNTs various conventional techniques like mouse lethality bioassay (MLB), SNAP-25 assay, mouse phrenic nerve hemidiaphragm (MPN) test, non-lethal mouse flaccid paralysis assay (NFPA) and modern techniques (immunoassays, cell-based assay, nucleic acid-based methods, endopeptidase mass spectrometry assays) have been discussed. This article also provides a detailed account on biosensing technology for detecting BoNTs in foods. Moreover, future research efforts should be focused on the development of advanced new-age biosensors for automated detection and real time monitoring of botulinum neurotoxin toxicity in food. Integration of biosensors with quantum technology and lab-on-chip platforms is required for increasing their versatility and robust detection. The insights presented in the review aim towards providing future research directions and increase the vigilance against potential future threats.
Collapse
Affiliation(s)
- Arzoo Saini
- Department of Biochemistry, School of Interdisciplinary & Applied Sciences, Central University of Haryana, Jant-Pali, Mahendergarh, 123031 India
| | - Neelam Yadav
- Department of Biochemistry, School of Interdisciplinary & Applied Sciences, Central University of Haryana, Jant-Pali, Mahendergarh, 123031 India.
| | - Bijender Singh
- Department of Biotechnology, School of Interdisciplinary & Applied Sciences, Central University of Haryana, Jant-Pali, Mahendergarh, 123031, India
| | - Jogender Singh Rana
- Department of Biotechnology, Deenbandhu Chhotu Ram University of Science and Technology, Murthal, Sonepat, 131039, India
| |
Collapse
|
2
|
Zhang L, Lv Q, Zheng Y, Gao S, Huang W, Liu P, Kong D, Wang Y, Yu Y, Jiang Y, Jiang H. Rapid and sensitive detection of botulinum toxin type A in complex sample matrices by AlphaLISA. Front Public Health 2022; 10:987517. [PMID: 36339146 PMCID: PMC9632490 DOI: 10.3389/fpubh.2022.987517] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 09/13/2022] [Indexed: 01/26/2023] Open
Abstract
Botulinum toxin A(BoNT/A) is a neurotoxin produced by the bacteria Clostridium botulinum, which can cause serious food poisoning and is recognized as a potential biological warfare agent. BoNT/A is does not degrade easily and can remain in the complex matrix for a long time. Meanwhile, the poisonous dose of botulinum toxin exceptionally low and intravenous human lethal doses estimated at 1-3 ng/kg. Therefore, sensitive and accurate detection methods suitable for testing a wide range of complex samples are urgently needed. To this end, the "amplified luminescent proximity homogeneous assay linked immunosorbent assay" (AlphaLISA) was established for the detection of BoNT/A and its detection efficacy in plasma, beverage, food, and other complex samples was evaluated. The results showed that this method can very effectively resist matrix interference. The detection time is rapid, reaching a detection limit for all samples of up to 0.1 ng/mL in only 30 min. BoNT/A can also be accurately detected in vomit samples of patients with clinical food poisoning. This study demonstrates that AlphaLISA is an effective tool for the detection of BoNT/A in complex samples and can potentially be developed for commercial use in the future.
Collapse
Affiliation(s)
- Liwen Zhang
- Anhui Medical University, Hefei, China,State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing, China
| | - Qingyu Lv
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing, China
| | - Yuling Zheng
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing, China
| | - Shan Gao
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing, China
| | - Wenhua Huang
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing, China
| | - Peng Liu
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing, China
| | - Decong Kong
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing, China
| | - Ye Wang
- State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing, China
| | - Yunzhou Yu
- Beijing Institute of Biotechnology, Beijing, China,*Correspondence: Yunzhou Yu
| | - Yongqiang Jiang
- Anhui Medical University, Hefei, China,State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing, China,Yongqiang Jiang
| | - Hua Jiang
- Anhui Medical University, Hefei, China,State Key Laboratory of Pathogen and Biosecurity, Institute of Microbiology and Epidemiology, Academy of Military Medical Sciences, Beijing, China,Hua Jiang
| |
Collapse
|
3
|
Graphene-Based Biosensors for Molecular Chronic Inflammatory Disease Biomarker Detection. BIOSENSORS 2022; 12:bios12040244. [PMID: 35448304 PMCID: PMC9030187 DOI: 10.3390/bios12040244] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 04/04/2022] [Accepted: 04/11/2022] [Indexed: 11/17/2022]
Abstract
Chronic inflammatory diseases, such as cancer, diabetes mellitus, stroke, ischemic heart diseases, neurodegenerative conditions, and COVID-19 have had a high number of deaths worldwide in recent years. The accurate detection of the biomarkers for chronic inflammatory diseases can significantly improve diagnosis, as well as therapy and clinical care in patients. Graphene derivative materials (GDMs), such as pristine graphene (G), graphene oxide (GO), and reduced graphene oxide (rGO), have shown tremendous benefits for biosensing and in the development of novel biosensor devices. GDMs exhibit excellent chemical, electrical and mechanical properties, good biocompatibility, and the facility of surface modification for biomolecular recognition, opening new opportunities for simple, accurate, and sensitive detection of biomarkers. This review shows the recent advances, properties, and potentialities of GDMs for developing robust biosensors. We show the main electrochemical and optical-sensing methods based on GDMs, as well as their design and manufacture in order to integrate them into robust, wearable, remote, and smart biosensors devices. We also describe the current application of such methods and technologies for the biosensing of chronic disease biomarkers. We also describe the current application of such methods and technologies for the biosensing of chronic disease biomarkers with improved sensitivity, reaching limits of detection from the nano to atto range concentration.
Collapse
|
4
|
Shenbagavalli K, Yadav SK, Ananthappan P, Sundaram E, Ponmariappan S, Vasantha VS. A simple and fast protocol for the synthesis of 2-amino-4-(4-formylphenyl)-4 H-chromene-3-carbonitrile to develop an optical immunoassay for the quantification of botulinum neurotoxin type F. NEW J CHEM 2020. [DOI: 10.1039/d0nj04103c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
In this study, a novel optical immunoassay platform using (S)-2-amino-4-(4-formylphenyl)-4H-chromene-3-carbonitrile, which was synthesized by an ultra-sonication method, as an optical probe.
Collapse
Affiliation(s)
| | - Shiv Kumar Yadav
- Defence Research and Development Establishment
- Gwalior-474 002
- India
| | | | - Ellairaja Sundaram
- Department of Chemistry
- Vivekanada College Tiruvedakam West
- Madurai 625 234
- India
| | | | | |
Collapse
|
5
|
von Berg L, Stern D, Weisemann J, Rummel A, Dorner MB, Dorner BG. Optimization of SNAP-25 and VAMP-2 Cleavage by Botulinum Neurotoxin Serotypes A-F Employing Taguchi Design-of-Experiments. Toxins (Basel) 2019; 11:toxins11100588. [PMID: 31614566 PMCID: PMC6832249 DOI: 10.3390/toxins11100588] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 10/01/2019] [Accepted: 10/09/2019] [Indexed: 11/17/2022] Open
Abstract
The detection of catalytically active botulinum neurotoxins (BoNTs) can be achieved by monitoring the enzymatic cleavage of soluble NSF (N-ethylmaleimide-sensitive-factor) attachment protein receptor (SNARE) proteins by the toxins’ light chains (LC) in cleavage-based assays. Thus, for sensitive BoNT detection, optimal cleavage conditions for the clinically relevant A–F serotypes are required. Until now, a systematic evaluation of cleavage conditions for the different BoNT serotypes is still lacking. To address this issue, we optimized cleavage conditions for BoNT/A–F using the Taguchi design-of-experiments (DoE) method. To this aim, we analyzed the influence of buffer composition (pH, Zn2+, DTT (dithiothreitol), NaCl) as well as frequently used additives (BSA (bovine serum albumin), Tween 20, trimethylamine N-oxide (TMAO)) on BoNT substrate cleavage. We identified major critical factors (DTT, Zn2+, TMAO) and were able to increase the catalytic efficiency of BoNT/B, C, E, and F when compared to previously described buffers. Moreover, we designed a single consensus buffer for the optimal cleavage of all tested serotypes. Our optimized buffers are instrumental to increase the sensitivity of cleavage-based assays for BoNT detection. Furthermore, the application of the Taguchi DoE approach shows how the method helps to rationally improve enzymatic assays.
Collapse
Affiliation(s)
- Laura von Berg
- Biological Toxins, Centre for Biological Threats and Special Pathogens, Robert Koch Institute, Seestr. 10, 13353 Berlin, Germany.
| | - Daniel Stern
- Biological Toxins, Centre for Biological Threats and Special Pathogens, Robert Koch Institute, Seestr. 10, 13353 Berlin, Germany.
| | - Jasmin Weisemann
- Institut für Toxikologie, Medizinische Hochschule Hannover, Carl-Neuberg-Str. 1, 30625 Hannover, Germany.
| | - Andreas Rummel
- Institut für Toxikologie, Medizinische Hochschule Hannover, Carl-Neuberg-Str. 1, 30625 Hannover, Germany.
| | - Martin Bernhard Dorner
- Biological Toxins, Centre for Biological Threats and Special Pathogens, Robert Koch Institute, Seestr. 10, 13353 Berlin, Germany.
| | - Brigitte Gertrud Dorner
- Biological Toxins, Centre for Biological Threats and Special Pathogens, Robert Koch Institute, Seestr. 10, 13353 Berlin, Germany.
| |
Collapse
|
6
|
A novel protein binding strategy for energy-transfer-based photoelectrochemical detection of enzymatic activity of botulinum neurotoxin A. Electrochem commun 2018. [DOI: 10.1016/j.elecom.2018.11.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
|
7
|
Eivazzadeh-Keihan R, Pashazadeh-Panahi P, Baradaran B, Guardia MDL, Hejazi M, Sohrabi H, Mokhtarzadeh A, Maleki A. Recent progress in optical and electrochemical biosensors for sensing of Clostridium botulinum neurotoxin. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.03.019] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
8
|
Imamura R, Murata N, Shimanouchi T, Yamashita K, Fukuzawa M, Noda M. A Label-Free Fluorescent Array Sensor Utilizing Liposome Encapsulating Calcein for Discriminating Target Proteins by Principal Component Analysis. SENSORS (BASEL, SWITZERLAND) 2017; 17:E1630. [PMID: 28714873 PMCID: PMC5539792 DOI: 10.3390/s17071630] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Revised: 07/05/2017] [Accepted: 07/13/2017] [Indexed: 01/10/2023]
Abstract
A new fluorescent arrayed biosensor has been developed to discriminate species and concentrations of target proteins by using plural different phospholipid liposome species encapsulating fluorescent molecules, utilizing differences in permeation of the fluorescent molecules through the membrane to modulate liposome-target protein interactions. This approach proposes a basically new label-free fluorescent sensor, compared with the common technique of developed fluorescent array sensors with labeling. We have confirmed a high output intensity of fluorescence emission related to characteristics of the fluorescent molecules dependent on their concentrations when they leak from inside the liposomes through the perturbed lipid membrane. After taking an array image of the fluorescence emission from the sensor using a CMOS imager, the output intensities of the fluorescence were analyzed by a principal component analysis (PCA) statistical method. It is found from PCA plots that different protein species with several concentrations were successfully discriminated by using the different lipid membranes with high cumulative contribution ratio. We also confirmed that the accuracy of the discrimination by the array sensor with a single shot is higher than that of a single sensor with multiple shots.
Collapse
Affiliation(s)
- Ryota Imamura
- Graduate School of Science and Technology, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan.
| | - Naoki Murata
- Graduate School of Science and Technology, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan.
| | - Toshinori Shimanouchi
- Graduate School of Environmental and Life Science, Okayama University, 1-1-1 Tsushima-naka, Kita-ku, Okayama 700-8530, Japan.
| | - Kaoru Yamashita
- Graduate School of Science and Technology, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan.
| | - Masayuki Fukuzawa
- Graduate School of Science and Technology, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan.
| | - Minoru Noda
- Graduate School of Science and Technology, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan.
| |
Collapse
|
9
|
Streak Imaging Flow Cytometer for Rare Cell Analysis. Methods Mol Biol 2017. [PMID: 28281262 DOI: 10.1007/978-1-4939-6848-0_17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
There is a need for simple and affordable techniques for cytology for clinical applications, especially for point-of-care (POC) medical diagnostics in resource-poor settings. However, this often requires adapting expensive and complex laboratory-based techniques that often require significant power and are too massive to transport easily. One such technique is flow cytometry, which has great potential for modification due to the simplicity of the principle of optical tracking of cells. However, it is limited in that regard due to the flow focusing technique used to isolate cells for optical detection. This technique inherently reduces the flow rate and is therefore unsuitable for rapid detection of rare cells which require large volume for analysis.To address these limitations, we developed a low-cost, mobile flow cytometer based on streak imaging. In our new configuration we utilize a simple webcam for optical detection over a large area associated with a wide-field flow cell. The new flow cell is capable of larger volume and higher throughput fluorescence detection of rare cells than the flow cells with hydrodynamic focusing used in conventional flow cytometry. The webcam is an inexpensive, commercially available system, and for fluorescence analysis we use a 1 W 450 nm blue laser to excite Syto-9 stained cells with emission at 535 nm. We were able to detect low concentrations of stained cells at high flow rates of 10 mL/min, which is suitable for rapidly analyzing larger specimen volumes to detect rare cells at appropriate concentration levels. The new rapid detection capabilities, combined with the simplicity and low cost of this device, suggest a potential for clinical POC flow cytometry in resource-poor settings associated with global health.
Collapse
|
10
|
Low-Cost Charged-Coupled Device (CCD) Based Detectors for Shiga Toxins Activity Analysis. Methods Mol Biol 2017. [PMID: 28281260 DOI: 10.1007/978-1-4939-6848-0_15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
To improve food safety there is a need to develop simple, low-cost sensitive devices for detection of food-borne pathogens and their toxins. We describe a simple, low-cost webcam-based detector which can be used for various optical detection modalities, including fluorescence, chemiluminescence, densitometry, and colorimetric assays. The portable battery-operated CCD-based detection system consists of four modules: (1) a webcam to measure and record light emission, (2) a sample plate to perform assays, (3) a light emitting diode (LED) for illumination, and (4) a portable computer to acquire and analyze images. To demonstrate the technology, we used a cell based assay for fluorescence detection of the activity of the food borne Shiga toxin type 2 (Stx2), differentiating between biologically active toxin and inactive toxin which is not a risk. The assay is based on Shiga toxin inhibition of cell protein synthesis measured through inhibition of the green fluorescent protein (GFP). In this assay, GFP emits light at 509 nm when excited with a blue LED equipped with a filter at 486 nm. The emitted light is then detected with a green filter at 535 nm. Toxin activity is measured through a reduction in the 509 nm emission. In this system the level of detection (LOD) for Stx2 was 0.1 pg/ml, similar to the LOD of commercial fluorometers. These results demonstrate the utility and potential of low cost detectors for toxin activity. This approach could be readily adapted to the detection of other food-borne toxins.
Collapse
|
11
|
Rasooly R, Bruck HA, Balsam J, Prickril B, Ossandon M, Rasooly A. Improving the Sensitivity and Functionality of Mobile Webcam-Based Fluorescence Detectors for Point-of-Care Diagnostics in Global Health. Diagnostics (Basel) 2016; 6:E19. [PMID: 27196933 PMCID: PMC4931414 DOI: 10.3390/diagnostics6020019] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Revised: 04/19/2016] [Accepted: 05/06/2016] [Indexed: 12/20/2022] Open
Abstract
Resource-poor countries and regions require effective, low-cost diagnostic devices for accurate identification and diagnosis of health conditions. Optical detection technologies used for many types of biological and clinical analysis can play a significant role in addressing this need, but must be sufficiently affordable and portable for use in global health settings. Most current clinical optical imaging technologies are accurate and sensitive, but also expensive and difficult to adapt for use in these settings. These challenges can be mitigated by taking advantage of affordable consumer electronics mobile devices such as webcams, mobile phones, charge-coupled device (CCD) cameras, lasers, and LEDs. Low-cost, portable multi-wavelength fluorescence plate readers have been developed for many applications including detection of microbial toxins such as C. Botulinum A neurotoxin, Shiga toxin, and S. aureus enterotoxin B (SEB), and flow cytometry has been used to detect very low cell concentrations. However, the relatively low sensitivities of these devices limit their clinical utility. We have developed several approaches to improve their sensitivity presented here for webcam based fluorescence detectors, including (1) image stacking to improve signal-to-noise ratios; (2) lasers to enable fluorescence excitation for flow cytometry; and (3) streak imaging to capture the trajectory of a single cell, enabling imaging sensors with high noise levels to detect rare cell events. These approaches can also help to overcome some of the limitations of other low-cost optical detection technologies such as CCD or phone-based detectors (like high noise levels or low sensitivities), and provide for their use in low-cost medical diagnostics in resource-poor settings.
Collapse
Affiliation(s)
- Reuven Rasooly
- Western Regional Research Center, Agricultural Research Service, U.S. Department of Agriculture, Albany, CA 94706, USA.
| | - Hugh Alan Bruck
- Department of Mechanical Engineering, University of Maryland College Park (UMCP), College Park, MD 20742, USA.
| | - Joshua Balsam
- Division of Chemistry and Toxicology Devices, Office of In Vitro Diagnostics and Radiological Health, FDA, Silver Spring, MD 20993, USA.
| | - Ben Prickril
- National Cancer Institute, Rockville, MD 208503, USA.
| | | | | |
Collapse
|
12
|
Balsam J, Bruck HA, Rasooly A. Two-layer Lab-on-a-chip (LOC) with passive capillary valves for mHealth medical diagnostics. Methods Mol Biol 2015; 1256:247-58. [PMID: 25626544 DOI: 10.1007/978-1-4939-2172-0_17] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/10/2023]
Abstract
There is a new potential to address needs for medical diagnostics in Point-of-Care (PoC) applications using mHealth (Mobile computing, medical sensors, and communications technologies for health care), a mHealth based lab test will require a LOC to perform clinical analysis. In this work, we describe the design of a simple Lab-on-a-chip (LOC) platform for mHealth medical diagnostics. The LOC utilizes a passive capillary valve with no moving parts for fluid control using channels with very low aspect ratios cross sections (i.e., channel width ≫ height) achieved through transitions in the channel geometry via that arrest capillary flow. Using a CO2 laser in raster engraving mode, we have designed and fabricated an eight-channel LOC for fluorescence signal detection fabricated by engraving and combining just two polymer layers. Each of the LOC channels is capable of mixing two reagents (e.g., enzyme and substrate) for various assays. For mHealth detection, we used a mobile CCD detector equipped with LED multispectral illumination in the red, green, blue, and white range. This technology enables the development of low-cost LOC platforms for mHealth whose fabrication is compatible with standard industrial plastic fabrication processes to enable mass production of mHealth diagnostic devices, which may broaden the use of LOCs in PoC applications, especially in global health settings.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, 10903 New Hampshire Avenue, Silver Spring, MD, 20993, USA
| | | | | |
Collapse
|
13
|
Balsam J, Bruck HA, Rasooly A. Webcam-based flow cytometer using wide-field imaging for low cell number detection at high throughput. Analyst 2015; 139:4322-9. [PMID: 24995370 DOI: 10.1039/c4an00669k] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Here we describe a novel low-cost flow cytometer based on a webcam capable of low cell number detection in a large volume which may overcome the limitations of current flow cytometry. Several key elements have been combined to yield both high throughput and high sensitivity. The first element is a commercially available webcam capable of 187 frames per second video capture at a resolution of 320 × 240 pixels. The second element in this design is a 1 W 450 nm laser module for area-excitation, which combined with the webcam allows for rapid interrogation of a flow field. The final element is a 2D flow-cell which overcomes the flow limitation of hydrodynamic focusing and allows for higher sample throughput in a wider flow field. This cell allows for the linear velocity of target cells to be lower than in a conventional "1D" hydrodynamic focusing flow-cells typically used in cytometry at similar volumetric flow rates. It also allows cells to be imaged at the full frame rate of the webcam. Using this webcam-based flow cytometer with wide-field imaging, it was confirmed that the detection of fluorescently tagged 5 μm polystyrene beads in "1D" hydrodynamic focusing flow-cells was not practical for low cell number detection due to streaking from the motion of the beads, which did not occur with the 2D flow-cell design. The sensitivity and throughput of this webcam-based flow cytometer was then investigated using THP-1 human monocytes stained with SYTO-9 florescent dye in the 2D flow-cell. The flow cytometer was found to be capable of detecting fluorescently tagged cells at concentrations as low as 1 cell per mL at flow rates of 500 μL min(-1) in buffer and in blood. The effectiveness of detection was concentration dependent: at 100 cells per mL 84% of the cells were detected compared to microscopy, 10 cells per mL 79% detected and 1 cell per mL 59% of the cells were detected. With the blood samples spiked to 100 cells per mL, the average concentration for all samples was 91.4 cells per mL, with a 95% confidence interval of 86-97 cells per mL. These low cell concentrations and the large volume capabilities of the system may overcome the limitations of current cytometry, and are applicable to rare cell (such as circulating tumor cell) detection The simplicity and low cost of this device suggests that it may have a potential use in developing point-of-care clinical flow cytometry for resource-poor settings associated with global health.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, USA
| | | | | |
Collapse
|
14
|
Srinivasan B, Tung S. Development and Applications of Portable Biosensors. ACTA ACUST UNITED AC 2015; 20:365-89. [DOI: 10.1177/2211068215581349] [Citation(s) in RCA: 122] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2014] [Indexed: 02/01/2023]
|
15
|
Lucas AD, Di Prima MA, Hitchins VM. Removal of Botulinum Neurotoxin a Surrogate from Reusable Medical Device Surfaces. APPLIED BIOSAFETY 2015. [DOI: 10.1177/153567601502000206] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- Anne D. Lucas
- U.S. Food and Drug Administration, Silver Spring, Maryland
| | | | | |
Collapse
|
16
|
Rasooly R, Balsam J, Hernlem BJ, Rasooly A. Sensitive detection of active Shiga toxin using low cost CCD based optical detector. Biosens Bioelectron 2015; 68:705-711. [PMID: 25677808 DOI: 10.1016/j.bios.2015.01.065] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2014] [Revised: 01/26/2015] [Accepted: 01/28/2015] [Indexed: 01/22/2023]
Abstract
To reduce the sources and incidence of food-borne illness there is a need to develop affordable, sensitive devices for detection of active toxins, such as Shiga toxin type 2 (Stx2). Currently the widely used methods for measuring Shiga toxin are immunoassay that cannot distinguish between the active form of the toxin, which poses a threat to life, to the inactive form which can bind to antibodies but show no toxicity. In this work, we determine toxin activity based on Shiga toxin inhibition of green fluorescent protein (GFP) combined with low cost charge-coupled device (CCD) fluorescence detection, which is more clinically relevant than immunoassay. For assay detection, a simple low cost fluorescence detection system was constructed using a CCD camera and light emitting diode (LED) excitation source, to measure GFP expression. The system was evaluated and compared to a commercial fluorometer using photomultiplier detection for detecting active Stx2 in the range 100 ng/mL-0.01 pg/mL. The result shows that there is a negative linear relationship between Stx2 concentrations and luminous intensity of GFP, imaged by the CCD camera (R(2)=0.85) or fluorometer (R(2)=0.86). The low cost (∼$300) CCD camera is capable of detecting Shiga toxin activity at comparable levels as a more expensive (∼$30,000) fluorometer. These results demonstrate the utility and the potential of low cost detectors for toxin activity; this approach may increase the availability of foodborne bacterial toxin diagnostics in regions where there are limited resources and could be readily adapted to the detection of other food-borne toxins.
Collapse
Affiliation(s)
- Reuven Rasooly
- Western Regional Research Center, Agricultural Research Service, U.S. Department of Agriculture, Albany, CA, United States.
| | - Josh Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, United States; University of Maryland, College Park, MD 20742, United States
| | - Bradley J Hernlem
- Western Regional Research Center, Agricultural Research Service, U.S. Department of Agriculture, Albany, CA, United States
| | - Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, United States; Office of Cancer Complementary and Alternative Medicine, National Cancer Institute, Rockville, MD 20850, United States
| |
Collapse
|
17
|
Balsam J, Bruck HA, Rasooly A. Cell streak imaging cytometry for rare cell detection. Biosens Bioelectron 2015; 64:154-60. [PMID: 25212069 PMCID: PMC4252841 DOI: 10.1016/j.bios.2014.08.065] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2014] [Revised: 08/19/2014] [Accepted: 08/22/2014] [Indexed: 11/30/2022]
Abstract
Detection of rare cells, such as circulating tumor cells, have many clinical applications. To measure rare cells with increased sensitivity and improved data managements, we developed an imaging flow cytometer with a streak imaging mode capability. The new streak mode imaging mode utilizes low speed video to capture moving fluorescently labeled cells in a flow cell. Each moving cell is imaged on multiple pixels on each frame, where the cell path is marked as a streak line proportional to the length of the exposure. Finding rare cells (e.g., <1 cell/mL) requires measuring larger sample volumes to achieve higher sensitivity, therefore we combined streak mode imaging with a "wide" high throughput flow cell (e.g. flow rates set to 10 mL/min) in contrast to the conventional "narrow" hydrodynamic focusing cells typically used in cytometry that are inherently limited to low flow rates. The new flow cell is capable of analyzing 20 mL/min of fluorescently labeled cells. To further increase sensitivity, the signal to noise ratio of the images was also enhanced by combining three imaging methods: (1) background subtraction, (2) pixel binning, and (3) CMOS color channel selection. The streaking mode cytometer has been used for the analysis of SYTO-9 labeled THP-1 human monocytes in buffer and in blood. Samples of cells at 1 cell/mL and 0.1 cell/mL were analyzed in 30 mL with flow rates set to 10 mL/min and frame rates of 4 fps (frame per second). For the target of 1 cell/mL, an average concentration of 0.91 cell/mL was measured by cytometry, with a standard error of 0.03 (C(95) = 0.85-0.97). For the target of 0.1 cell/mL, an average concentration of 0.083 cell/mL was measured, with a standard error of 0.01 (C(95) = 0.065-0.102). Whole blood was also spiked with SYTO-9 labeled cells to a concentration of 10 cell/mL, and the average flow cytometry measurement was 8.7 cells/mL (i.e. 0.87 cells/mL in diluted blood) with a 95% CL of 8.1-9.2 cells/mL. This demonstrated the ability to detect rare cells in blood with high accuracy. Such detection approaches for rare cells have many potential clinical applications. Furthermore, the simplicity and low cost of this device may enable expansion of cell-based clinical diagnostics, especially in resource-poor settings.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, United States; University of Maryland, College Park, MD 20742, United States
| | - Hugh Alan Bruck
- University of Maryland, College Park, MD 20742, United States
| | - Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, United States; Office of Cancer Complementary and Alternative Medicine, National Cancer Institute, Rockville, MD 20850, United States.
| |
Collapse
|
18
|
Abstract
We describe here a compact smartphone-based fluorescence detector for mHealth. A key element to achieving high sensitivity using low sensitivity phone cameras is a capillary array, which increases sensitivity by 100×. The capillary array was combined with a white LED illumination system to enable wide spectra fluorescent excitation in the range of 450-740 nm. The detector utilizes an orthographic projection system to form parallel light projection images from the capillaries at a close distance via an object-space telecentric lens configuration that reduces the total lens-to-object distance while maintaining uniformity in measurement between capillaries. To further increase the limit of detection (LOD), a computational image processing approach was employed to decrease the level of noise. This enables an additional 5-10× decrease in LOD. This smartphone-based detector was used to measure serial dilutions of fluorescein with a LOD of 1 nM with image stacking and 10 nM without image stacking, similar to the LOD obtained with a commercial plate reader. Moreover, the capillary array required a sample volume of less than 10 μl, which is an order of magnitude less than the 100 μl required for the plate reader.As fluorescence detection is widely used in sensitive biomedical assays, the approach described here has the potential to increase mHealth clinical utility, especially for telemedicine and for resource-poor settings in global health applications.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, 10903 New Hampshire Avenue, Silver Spring, MD, 20993, USA
| | | | | |
Collapse
|
19
|
Abstract
Flow cytometry is used for cell counting and analysis in numerous clinical and environmental applications. However flow cytometry is not used in mHealth mainly because current flow cytometers are large, expensive, power-intensive devices designed to operate in a laboratory. Their design results in a lack of portability and makes them unsuitable for mHealth applications. Another limitation of current technology is the low volumetric throughput rates that are not suitable for rapid detection of rare cells.To address these limitations, we describe here a novel, low-cost, mobile flow cytometer based on wide-field imaging with a webcam for large volume and high throughput fluorescence detection of rare cells as a simulation for circulating tumor cells (CTCs) detection. The mobile flow cytometer uses a commercially available webcam capable of 187 frames per second video capture at a resolution of 320 × 240 pixels. For fluorescence detection, a 1 W 450 nm blue laser is used for excitation of Syto-9 fluorescently stained cells detected at 535 nm. A wide-field flow cell was developed for large volume analysis that allows for the linear velocity of target cells to be lower than in conventional hydrodynamic focusing flow cells typically used in cytometry. The mobile flow cytometer was found to be capable of detecting low concentrations at flow rates of 500 μL/min, suitable for rare cell detection in large volumes. The simplicity and low cost of this device suggests that it may have a potential clinical use for mHealth flow cytometry for resource-poor settings associated with global health.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD, 20993, USA
| | | | | |
Collapse
|
20
|
Li L, Xia LR, Wang HY, Bi XD. New method for fabricating an α-fetoprotein affinity monolithic polymer array. J Appl Polym Sci 2014. [DOI: 10.1002/app.41792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Li Li
- Institute of Facilities and Equipment in Agriculture; Jiangsu Academy of Agricultural Sciences; Nanjing 210014 China
| | - Li-Ru Xia
- Institute of Facilities and Equipment in Agriculture; Jiangsu Academy of Agricultural Sciences; Nanjing 210014 China
| | - He-Ye Wang
- Institute of Facilities and Equipment in Agriculture; Jiangsu Academy of Agricultural Sciences; Nanjing 210014 China
| | - Xiao-Dong Bi
- Key Laboratory of Analytical Chemistry for Life Science; School of Chemistry and Chemical Engineering; Nanjing University; Nanjing 210093 China
| |
Collapse
|
21
|
Shi J, Guo J, Bai G, Chan C, Liu X, Ye W, Hao J, Chen S, Yang M. A graphene oxide based fluorescence resonance energy transfer (FRET) biosensor for ultrasensitive detection of botulinum neurotoxin A (BoNT/A) enzymatic activity. Biosens Bioelectron 2014; 65:238-44. [PMID: 25461164 DOI: 10.1016/j.bios.2014.10.050] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2014] [Revised: 10/17/2014] [Accepted: 10/20/2014] [Indexed: 11/18/2022]
Abstract
Botulinum neurotoxins (BoNTs) are among the most potent toxic bacterial proteins for humans, which make them potential agents for bioterrorism. Therefore, an ultrasensitive detection of BoNTs and their active states is in great need as field-deployable systems for anti-terrorism applications. We report the construction of a novel graphene oxide (GO)-peptide based fluorescence resonance energy transfer (FRET) biosensor for ultrasensitive detection of the BoNT serotype A light chain (BoNT-LcA) protease activity. A green fluorescence protein (GFP) modified SNAP-25 peptide substrate (SNAP-25-GFP) was optimally designed and synthesized with the centralized recognition/cleavage sites. This FRET platform was constructed by covalent immobilization of peptide substrate on GO with BSA passivation which have advantages of low non-specific adsorption and high stability in protein abundant solution. BoNT-LcA can specifically cleave SNAP-25-GFP substrate covalently immobilized on GO to release the fragment with GFP. Based on fluorescence signal recovery measurement, the target BoNT-LcA was detected sensitively and selectively with the linear detection range from 1fg/mL to 1pg/mL. The limit of detection (LOD) for BoNT-LcA is around 1fg/mL.
Collapse
Affiliation(s)
- Jingyu Shi
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, PR China
| | - Jiubiao Guo
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Gongxun Bai
- Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Chunyu Chan
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, PR China
| | - Xuan Liu
- Institute of Textiles & Clothing, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Weiwei Ye
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, PR China
| | - Jianhua Hao
- Department of Applied Physics, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Sheng Chen
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Mo Yang
- Interdisciplinary Division of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, PR China.
| |
Collapse
|
22
|
Li L, Bi XD, Feng M, Zhu JT. UV-initiated copolymerization route for facile fabrication of epoxy-functionalized micro-zone plates. J Appl Polym Sci 2014. [DOI: 10.1002/app.39787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Li Li
- Department of Nuclear Agricultural Science; Institute of Facilities and Equipment in Agriculture, Jiangsu Academy of Agricultural Sciences; Nanjing 210014 China
| | - Xiao-Dong Bi
- Key Laboratory of Analytical Chemistry for Life Science; School of Chemistry and Chemical Engineering; Nanjing University; Nanjing 210093 China
| | - Min Feng
- Department of Nuclear Agricultural Science; Institute of Facilities and Equipment in Agriculture, Jiangsu Academy of Agricultural Sciences; Nanjing 210014 China
| | - Jia-Ting Zhu
- Department of Nuclear Agricultural Science; Institute of Facilities and Equipment in Agriculture, Jiangsu Academy of Agricultural Sciences; Nanjing 210014 China
| |
Collapse
|
23
|
Bruck HA, Yang M, Kostov Y, Rasooly A. Electrical percolation based biosensors. Methods 2013; 63:282-9. [PMID: 24041756 PMCID: PMC3902888 DOI: 10.1016/j.ymeth.2013.08.031] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2013] [Revised: 07/30/2013] [Accepted: 08/28/2013] [Indexed: 01/29/2023] Open
Abstract
A new approach to label free biosensing has been developed based on the principle of "electrical percolation". In electrical percolation, long-range electrical connectivity is formed in randomly oriented and distributed systems of discrete elements. By applying this principle to biological interactions, it is possible to measure biological components both directly and electronically. The main element for electrical percolation biosensor is the biological semiconductor (BSC) which is a multi-layer 3-D carbon nanotube-antibody network. In the BSC, molecular interactions, such as binding of antigens to the antibodies, disrupt the network continuity causing increased resistance of the network. BSCs can be fabricated by immobilizing conducting elements, such as pre-functionalized single-walled carbon nanotubes (SWNTs)-antibody complex, directly onto a substrate, such as a Poly(methyl methacrylate) (PMMA) surface (also known as plexi-glass or Acrylic). BSCs have been demonstrated for direct (label-free) electronic measurements of antibody-antigen binding using SWNTs. If the concentration of the SWNT network is slightly above the electrical percolation threshold, then binding of a specific antigen to the pre-functionalized SWNT dramatically increases the electrical resistance due to changes in the tunneling between the SWNTs. Using anti-staphylococcal enterotoxin B (SEB) IgG as a "gate" and SEB as an "actuator", it was demonstrated that the BSC was able to detect SEB at concentrations of 1 ng/ml. Based on this concept, an automated configuration for BSCs is described here that enables real time continuous detection. The new BSC configuration may permit assembly of multiple sensors on the same chip to create "biological central processing units (CPUs)" with multiple biological elements, capable of processing and sorting out information on multiple analytes simultaneously.
Collapse
Affiliation(s)
- Hugh Alan Bruck
- University of Maryland College Park (UMCP), College Park MD 20742
| | - Minghui Yang
- College of Chemistry and Chemical Engineering, Central South University, Changsha, China, 410083, China
| | | | - Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993
- National Cancer Institute, Rockville, MD 20850
| |
Collapse
|
24
|
Balsam J, Bruck HA, Rasooly A. Capillary Array Waveguide Amplified Fluorescence Detector for mHealth. SENSORS AND ACTUATORS. B, CHEMICAL 2013; 186:711-717. [PMID: 24039345 PMCID: PMC3769705 DOI: 10.1016/j.snb.2013.06.030] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Mobile Health (mHealth) analytical technologies are potentially useful for carrying out modern medical diagnostics in resource-poor settings. Effective mHealth devices for underserved populations need to be simple, low cost, and portable. Although cell phone cameras have been used for biodetection, their sensitivity is a limiting factor because currently it is too low to be effective for many mHealth applications, which depend on detection of weak fluorescent signals. To improve the sensitivity of portable phones, a capillary tube array was developed to amplify fluorescence signals using their waveguide properties. An array configured with 36 capillary tubes was demonstrated to have a ~100X increase in sensitivity, lowering the limit of detection (LOD) of mobile phones from 1000 nM to 10 nM for fluorescein. To confirm that the amplification was due to waveguide behavior, we coated the external surfaces of the capillaries with silver. The silver coating interfered with the waveguide behavior and diminished the fluorescence signal, thereby proving that the waveguide behavior was the main mechanism for enhancing optical sensitivity. The optical configuration described here is novel in several ways. First, the use of capillaries waveguide properties to improve detection of weak florescence signal is new. Second we describe here a three dimensional illumination system, while conventional angular laser waveguide illumination is spot (or line), which is functionally one-dimensional illumination, can illuminate only a single capillary or a single column (when a line generator is used) of capillaries and thus inherently limits the multiplexing capability of detection. The planar illumination demonstrated in this work enables illumination of a two dimensional capillary array (e.g. x columns and y rows of capillaries). In addition, the waveguide light propagation via the capillary wall provides a third dimension for illumination along the axis of the capillaries. Such an array can potentially be used for sensitive analysis of multiple fluorescent detection assays simultaneously. The simple phone based capillary array approach presented in this paper is capable of amplifying weak fluorescent signals thereby improving the sensitivity of optical detectors based on mobile phones. This may allow sensitive biological assays to be measured with low sensitivity detectors and may make mHealth practical for many diagnostics applications, especially in resource-poor and global health settings.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993 ; University of Maryland, College Park, MD 20742
| | | | | |
Collapse
|
25
|
Balsam J, Ossandon M, Bruck HA, Lubensky I, Rasooly A. Low-cost technologies for medical diagnostics in low-resource settings. ACTA ACUST UNITED AC 2013; 7:243-55. [DOI: 10.1517/17530059.2013.767796] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
26
|
Rasooly A, Kostov Y, Bruck HA. Charged-coupled device (CCD) detectors for Lab-on-a Chip (LOC) optical analysis. Methods Mol Biol 2013; 949:365-385. [PMID: 23329454 DOI: 10.1007/978-1-62703-134-9_23] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A critical element of any Lab-on-a-Chip (LOC) is a detector; among the many detection approaches, optical detection is very widely used for biodetection. One challenge for advancing the development of LOC for biodetection has been to enhance the portability and lower the cost for Point-of-Care diagnostics, which has the potential to enhance the quality of healthcare delivery for underserved populations and for global health. We describe a simple and relatively low cost charged-coupled device (CCD)-based detector that can be integrated with a conventional microtiter plate or a portable LOC assay for various optical detection modalities including fluorescence, chemiluminescence, densitometry, and colorimetric assays. In general, the portable battery-operated CCD-based detection system consists of four modules: (1) a cooled CCD digital camera to monitor light emission, (2) a LOC or microtiter plate to perform assays, (3) a light source to illuminate the assay (such as electroluminescence (EL) or light emitting diode (LED)), and (4) a portable computer to acquire and analyze images. The configuration of the fluorescence detector presented here was designed to measure fluorogenic excitation at 490 nm and to monitor emission at 523 nm used for FITC detection.The LOC used for this detection system was fabricated with laminated object manufacturing (LOM) technology, and was designed to detection activity of botulinum neurotoxin serotype A (BoNT-A) using a fluorogenic peptide substrate (SNAP-25) for botulinum neurotoxin serotype A (BoNT-A) labeled with FITC. The limit of detection (LOD) for the CCD detector is 0.5 nM (25 ng/ml). The portable system is small and is powered by a 12 V source. The modular detector was designed with easily interchangeable LEDs, ELs, filters, lenses, and LOC, and can be used and adapted for a wide variety of densitometry, florescence and colorimetric assays.
Collapse
Affiliation(s)
- Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA Center for Devices and Radiological Health (CDRH), Silver Spring, MD, USA.
| | | | | |
Collapse
|
27
|
Abstract
Laminated object manufacturing (LOM) technology using polymer sheets is an easy and affordable method for rapid prototyping of Lab-on-a-Chip (LOC) systems. It has recently been used to fabricate a miniature 96 sample ELISA lab-on-a-chip (ELISA-LOC) by integrating the washing step directly into an ELISA plate. LOM has been shown to be capable of creating complex 3D microfluidics through the assembly of a stack of polymer sheets with features generated by laser micromachining and by bonding the sheets together with adhesive. A six layer ELISA-LOC was fabricated with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser with simple microfluidic features including a miniature 96-well sample plate. Immunological assays can be carried out in several configurations (1 × 96 wells, 2 × 48 wells, or 4 × 24 wells). The system includes three main functional elements: (1) a reagent loading fluidics module, (2) an assay and detection wells plate, and (3) a reagent removal fluidics module. The ELISA-LOC system combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected Staphylococcal enterotoxin B (SEB) at concentrations as low as 0.1 ng/ml, a detection level similar to that reported for conventional ELISA. ELISA-LOC can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without the laboratory required for conventional ELISA, and therefore may be more useful for global healthcare delivery.
Collapse
Affiliation(s)
- Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA Center for Devices and Radiological Health (CDRH), Silver Spring, MD, USA.
| | | | | |
Collapse
|
28
|
Abstract
Enzymes are key molecules in signal-transduction pathways. However, only a small fraction of more than 500 human kinases, 300 human proteases and 200 human phosphatases is characterised so far. Peptide microarray based technologies for extremely efficient profiling of enzyme substrate specificity emerged in the last years. This technology reduces set-up time for HTS assays and allows the identification of downstream targets. Moreover, peptide microarrays enable optimisation of enzyme substrates. Focus of this review is on assay principles for measuring activities of kinases, phosphatases or proteases and on substrate identification/optimisation for kinases. Additionally, several examples for reliable identification of substrates for lysine methyl-transferases, histone deacetylases and SUMO-transferases are given. Finally, use of high-density peptide microarrays for the simultaneous profiling of kinase activities in complex biological samples like cell lysates or lysates of complete organisms is described. All published examples of peptide arrays used for enzyme profiling are summarised comprehensively.
Collapse
|
29
|
Balsam J, Bruck HA, Kostov Y, Rasooly A. Image stacking approach to increase sensitivity of fluorescence detection using a low cost complementary metal-oxide-semiconductor (CMOS) webcam. SENSORS AND ACTUATORS. B, CHEMICAL 2012; 171-172:141-147. [PMID: 23990697 PMCID: PMC3752898 DOI: 10.1016/j.snb.2012.02.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Optical technologies are important for biological analysis. Current biomedical optical analyses rely on high-cost, high-sensitivity optical detectors such as photomultipliers, avalanched photodiodes or cooled CCD cameras. In contrast, Webcams, mobile phones and other popular consumer electronics use lower-sensitivity, lower-cost optical components such as photodiodes or CMOS sensors. In order for consumer electronics devices, such as webcams, to be useful for biomedical analysis, they must have increased sensitivity. We combined two strategies to increase the sensitivity of CMOS-based fluorescence detector. We captured hundreds of low sensitivity images using a Webcam in video mode, instead of a single image typically used in cooled CCD devices.We then used a computational approach consisting of an image stacking algorithm to remove the noise by combining all of the images into a single image. While video mode is widely used for dynamic scene imaging (e.g. movies or time-lapse photography), it is not used to capture a single static image, which removes noise and increases sensitivity by more than thirty fold. The portable, battery-operated Webcam-based fluorometer system developed here consists of five modules: (1) a low cost CMOS Webcam to monitor light emission, (2) a plate to perform assays, (3) filters and multi-wavelength LED illuminator for fluorophore excitation, (4) a portable computer to acquire and analyze images, and (5) image stacking software for image enhancement. The samples consisted of various concentrations of fluorescein, ranging from 30 μM to 1000 μM, in a 36-well miniature plate. In the single frame mode, the fluorometer's limit-of-detection (LOD) for fluorescein is ∼1000 μM, which is relatively insensitive. However, when used in video mode combined with image stacking enhancement, the LOD is dramatically reduced to 30 μM, sensitivity which is similar to that of state-of-the-art ELISA plate photomultiplier-based readers. Numerous medical diagnostics assays rely on optical and fluorescence readers. Our novel combination of detection technologies, which is new to biodetection may enable the development of new low cost optical detectors based on an inexpensive Webcam (<$10). It has the potential to form the basis for high sensitivity, low cost medical diagnostics in resource-poor settings.
Collapse
Affiliation(s)
- Joshua Balsam
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, United States
- University of Maryland College Park (UMCP), College Park, MD 20742, United States
| | - Hugh Alan Bruck
- University of Maryland College Park (UMCP), College Park, MD 20742, United States
| | - Yordan Kostov
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250, United States
| | - Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, United States
- National Cancer Institute, Bethesda, MD 20892, United States
| |
Collapse
|
30
|
Dorner MB, Schulz KM, Kull S, Dorner BG. Complexity of Botulinum Neurotoxins: Challenges for Detection Technology. Curr Top Microbiol Immunol 2012. [DOI: 10.1007/978-3-662-45790-0_11] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
31
|
Gubala V, Harris LF, Ricco AJ, Tan MX, Williams DE. Point of Care Diagnostics: Status and Future. Anal Chem 2011; 84:487-515. [DOI: 10.1021/ac2030199] [Citation(s) in RCA: 832] [Impact Index Per Article: 59.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Vladimir Gubala
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - Leanne F. Harris
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - Antonio J. Ricco
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - Ming X. Tan
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| | - David E. Williams
- Biomedical Diagnostics Institute, Dublin City University, Dublin 9, Ireland
| |
Collapse
|
32
|
A comparative evaluation of microarray slides as substrates for the development of protease assay biosensors. Exp Mol Pathol 2011; 91:714-7. [DOI: 10.1016/j.yexmp.2011.09.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2011] [Accepted: 09/06/2011] [Indexed: 11/20/2022]
|
33
|
Yang M, Sun S, Kostov Y, Rasooly A. An automated point-of-care system for immunodetection of staphylococcal enterotoxin B. Anal Biochem 2011; 416:74-81. [PMID: 21640067 PMCID: PMC3148523 DOI: 10.1016/j.ab.2011.05.014] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2011] [Revised: 04/28/2011] [Accepted: 05/10/2011] [Indexed: 01/19/2023]
Abstract
An automated point-of-care (POC) immunodetection system for immunological detection of staphylococcal enterotoxin B (SEB) was designed, fabricated, and tested. The system combines several elements: (i) enzyme-linked immunosorbent assay-lab-on-a-chip (ELISA-LOC) with fluidics, (ii) a charge-coupled device (CCD) camera detector, (iii) pumps and valves for fluid delivery to the ELISA-LOC, (iv) a computer interface board, and (v) a computer for controlling the fluidics, logging, and data analysis of the CCD data. The ELISA-LOC integrates a simple microfluidic system into a miniature 96-well sample plate, allowing the user to carry out immunological assays without a laboratory. The analyte is measured in a sandwich ELISA assay format combined with a sensitive electrochemiluminescence (ECL) detection method. Using the POC system, SEB, a major foodborne toxin, was detected at concentrations as low as 0.1 ng/ml. This is similar to the reported sensitivity of conventional ELISA. The open platform with simple modular fluid delivery automation design described here is interchangeable between detection systems, and because of its versatility it can also be used to automate many other LOC systems, simplifying LOC development. This new POC system is useful for carrying out various immunological and other complex medical assays without a laboratory and can easily be adapted for high-throughput biological screening in remote and resource-poor areas.
Collapse
Affiliation(s)
- Minghui Yang
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Steven Sun
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993
| | - Yordan Kostov
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250
| | - Avraham Rasooly
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993
- National Cancer Institute, Bethesda, MD 20892
| |
Collapse
|
34
|
Balsam J, Ossandon M, Kostov Y, Bruck HA, Rasooly A. Lensless CCD-based fluorometer using a micromachined optical Söller collimator. LAB ON A CHIP 2011; 11:941-9. [PMID: 21243150 DOI: 10.1039/c0lc00431f] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
In this paper, we describe a simple charge-coupled device (CCD) based lensless fluorometer with sensitivity in the range of current ELISA plate readers. In our lensfree fluorometer, a multi-wavelength LED light source was used for fluorophore excitation. To collimate the light, we developed a simple optical Söller collimator based on a "stack of pinholes" (a stack of black PMMA with array of pinholes machined with laser) enabling the light to be collimated from the LED through the filters and the assay's microfluidics directly onto the CCD without a lens. The elimination of the lens that is used in almost all other current CCD based detection systems has four major advantages: (1) It simplifies the device design and fabrication while reducing cost. (2) It reduces the distance between the sample and the measuring device (without a lens the distance needed to focus the image on the CCD is reduced and the fluorometer can be more compact). (3) It couples the CCD and the detected surface by using an optical Söller Collimator which allows the use of filters for fluorescence detection. (4) It also uncouples the CCD and the microfluidics to enable the use of interchangeable fluidics while protecting the delicate CCD. The lensless CCD-based fluorometer is capable of detecting 16 samples simultaneously, and was used for in vitro detection of botulinum neurotoxin serotype A (BoNT-A) activity with a FRET assay that measures cleavage of a fluorophore-tagged peptide substrate specific for BoNT-A (SNAP-25) by the toxin light chain (LcA). The limit of detection (LOD) of our lensless fluorometer is 1.25 nM, which is similar to the LOD of a modern ELISA plate reader. Combined with microfluidics, this simple low cost point-of-care (POC) medical diagnostic system may be useful for the performance of many other complex medical diagnostic assays without a laboratory and thus potentially enhancing the accessibility and the quality of health care delivery in underserved populations.
Collapse
Affiliation(s)
- Joshua Balsam
- University of Maryland College Park (UMCP), College Park, MD 20742, USA
| | | | | | | | | |
Collapse
|
35
|
Frisk ML, Lin G, Johnson EA, Beebe DJ. Synaptotagmin II peptide-bead conjugate for botulinum toxin enrichment and detection in microchannels. Biosens Bioelectron 2011; 26:1929-35. [DOI: 10.1016/j.bios.2010.06.035] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2010] [Revised: 05/27/2010] [Accepted: 06/23/2010] [Indexed: 11/29/2022]
|
36
|
Sun S, Yang M, Kostov Y, Rasooly A. ELISA-LOC: lab-on-a-chip for enzyme-linked immunodetection. LAB ON A CHIP 2010; 10:2093-100. [PMID: 20544092 DOI: 10.1039/c003994b] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
A miniature 96 sample ELISA-lab-on-a-chip (ELISA-LOC) was designed, fabricated, and tested for immunological detection of Staphylococcal Enterotoxin B (SEB). The chip integrates a simple microfluidics system into a miniature ninety-six sample plate, allowing the user to carry out an immunological assay without a laboratory. Assay reagents are delivered into the assay plate without the need for separate devices commonly used in immunoassays. The ELISA-LOC was constructed using Laminated Object Manufacturing (LOM) technology to assemble six layers with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser. The ELISA-LOC has three main functional elements: reagent loading fluidics, assay and detection wells, and reagent removal fluidics, a simple "surface tension" valve used to control the flow. To enhance assay sensitivity and to perform the assay without a lab, ELISA-LOC detection combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected SEB at concentrations as low as 0.1 ng ml(-1), which is similar to the reported sensitivity of conventional ELISA. The fluidics system can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without a laboratory.
Collapse
Affiliation(s)
- Steven Sun
- Division of Biology, Office of Science and Engineering, FDA, Silver Spring, MD 20993, USA
| | | | | | | |
Collapse
|
37
|
Yang M, Bruck HA, Kostov Y, Rasooly A. Biological semiconductor based on electrical percolation. Anal Chem 2010; 82:3567-72. [PMID: 20361741 DOI: 10.1021/ac902644z] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We have developed a novel biological semiconductor (BSC) based on electrical percolation through a multilayer three-dimensional carbon nanotube-antibody bionanocomposite network, which can measure biological interactions directly and electronically. In electrical percolation, the passage of current through the conductive network is dependent upon the continuity of the network. Molecular interactions, such as binding of antigens to the antibodies, disrupt the network continuity causing increased resistance of the network. A BSC is fabricated by immobilizing a prefunctionalized single-walled carbon nanotubes (SWNTs)-antibody bionanocomposite directly on a poly(methyl methacrylate) (PMMA) surface (also known as plexiglass or acrylic). We used the BSC for direct (label-free) electronic measurements of antibody-antigen binding, showing that, at slightly above the electrical percolation threshold of the network, binding of a specific antigen dramatically increases the electrical resistance. Using anti-staphylococcal enterotoxin B (SEB) IgG as a "gate" and SEB as an "actuator", we demonstrated that the BSC was able to detect SEB at concentrations of 1 ng/mL. The new BSCs may permit assembly of multiple sensors on the same chip to create "biological central processing units (CPUs)" with multiple BSC elements, capable of processing and sorting out information on multiple analytes simultaneously.
Collapse
Affiliation(s)
- Minghui Yang
- Center for Advanced Sensor Technology, University of Maryland, Baltimore County, Maryland 21250, USA
| | | | | | | |
Collapse
|
38
|
Yang M, Sun S, Kostov Y, Rasooly A. Lab-On-a-Chip for carbon nanotubes based immunoassay detection of Staphylococcal Enterotoxin B (SEB). LAB ON A CHIP 2010; 10:1011-1017. [PMID: 20358108 DOI: 10.1039/b923996k] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
We describe a new eight channel Lab-On-a-Chip (LOC) for a Carbon Nanotube (CNT) based immunoassay with optical detection of Staphylococcal Enterotoxin B (SEB) for food safety applications. In this work, we combined four biosensing elements: (1) CNT technology for primary antibody immobilization, (2) Enhanced Chemiluminescence (ECL) for light signal generation, (3) a cooled charge-coupled device (CCD) for detection and (4) polymer lamination technology for developing a point of care immunological assay for SEB detection. Our concept for developing versatile LOCs, which can be used for many different applications, is to use a modular design with interchangeable recognition elements (e.g. various antibodies) to determine the specificity. Polymer lamination technology was used for the fabrication of a six layer, syringe operated LOC capable of analyzing eight samples simultaneously. An anti-SEB antibody-nanotube mixture was immobilized onto a polycarbonate strip, to serve as an interchangeable ligand surface that was then bonded onto the LOC. SEB samples are loaded into the device and detected by an ELISA assay using Horse Radish Peroxidase (HRP) conjugated anti-SEB IgG as a secondary antibody and ECL, with detection by a previously described portable cooled CCD detector. Eight samples of SEB in buffer or soy milk were assayed simultaneously with a limit of detection of 0.1 ng mL(-1). CNT immobilization of the antibody increased the sensitivity of detection six fold. Use of a simple interchangeable immunological surface allows this LOC to be adapted to any immunoassay by simply replacing the ligand surface. A syringe was used to move fluids for this assay so no power is needed to operate the device. Our versatile portable point-of-care CCD detector combined with the LOC immunoassay method described here can be used to reduce the exposure of users to toxins and other biohazards when working outside the lab, as well as to simplify and increase sensitivity for many other types of immunological diagnostics and detection assays.
Collapse
Affiliation(s)
- Minghui Yang
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250, USA
| | | | | | | |
Collapse
|
39
|
Sun S, Francis J, Sapsford KE, Kostov Y, Rasooly A. Multi-wavelength Spatial LED illumination based detector for in vitro detection of Botulinum Neurotoxin A Activity. SENSORS AND ACTUATORS. B, CHEMICAL 2010; 146:297-306. [PMID: 20498728 PMCID: PMC2874159 DOI: 10.1016/j.snb.2010.02.009] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
A portable and rapid detection system for the activity analysis of Botulinum Neurotoxins (BoNT) is needed for food safety and bio-security applications. To improve BoNT activity detection, a previously designed portable charge-coupled device (CCD) based detector was modified and equipped with a higher intensity more versatile multi-wavelength spatial light-emitting diode (LED) illumination, a faster CCD detector and the capability to simultaneously detect 30 samples. A FITC/DABCYL Förster Resonance Energy Transfer (FRET)-labeled peptide substrate (SNAP-25), with BoNT-A target cleavage site sequence was used to measure BoNT-A light chain (LcA) activity through the FITC fluorescence increase that occurs upon peptide substrate cleavage. For fluorescence excitation, a multi-wavelength spatial LED illuminator was used and compared to our previous electroluminescent (EL) strips. The LED illuminator was equipped with blue, green, red and white LEDs, covering a spectrum of 450-680 nm (red 610-650 nm, green 492-550 nm, blue 450-495 nm, and white LED 440-680 nm). In terms of light intensity, the blue LED was found to be ~80 fold higher than the previously used blue EL strips. When measuring the activity of LcA the CCD detector limit of detection (LOD) was found to be 0.08 nM LcA for both the blue LED (2 s exposure) and the blue EL (which require ≥60 s exposure) while the limits of quantitation (LOQ) is about 1 nM. The LOD for white LED was higher at 1.4 nM while the white EL was not used for the assay due to a high variable background. Unlike the weaker intensity EL illumination the high intensity LED illumination enabled shorter exposure times and allowed multi-wavelength illumination without the need to physically change the excitation strip, thus making spectrum excitation of multiple fluorophores possible increasing the versatility of the detector platform for a variety of optical detection assays.
Collapse
Affiliation(s)
- Steven Sun
- Division of Biology, Office of Science and Engineering Laboratories, FDA, Silver Spring, MD 20993, USA
| | | | | | | | | |
Collapse
|
40
|
Sapsford KE, Blanco-Canosa JB, Dawson PE, Medintz IL. Detection of HIV-1 Specific Monoclonal Antibodies Using Enhancement of Dye-Labeled Antigenic Peptides. Bioconjug Chem 2010; 21:393-8. [DOI: 10.1021/bc9003712] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Kim E. Sapsford
- Division of Biology, Office of Science and Engineering Laboratories, FDA, Silver Spring, Maryland 20993, Departments of Cell Biology and Chemistry and the Skaggs Institute for Chemical Biology, The Scripps Research Institute, La Jolla, California 92037, and Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, DC 20375
| | - Juan B. Blanco-Canosa
- Division of Biology, Office of Science and Engineering Laboratories, FDA, Silver Spring, Maryland 20993, Departments of Cell Biology and Chemistry and the Skaggs Institute for Chemical Biology, The Scripps Research Institute, La Jolla, California 92037, and Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, DC 20375
| | - Philip E. Dawson
- Division of Biology, Office of Science and Engineering Laboratories, FDA, Silver Spring, Maryland 20993, Departments of Cell Biology and Chemistry and the Skaggs Institute for Chemical Biology, The Scripps Research Institute, La Jolla, California 92037, and Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, DC 20375
| | - Igor L. Medintz
- Division of Biology, Office of Science and Engineering Laboratories, FDA, Silver Spring, Maryland 20993, Departments of Cell Biology and Chemistry and the Skaggs Institute for Chemical Biology, The Scripps Research Institute, La Jolla, California 92037, and Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, DC 20375
| |
Collapse
|
41
|
Abstract
Sensitive and rapid detection of botulinum neurotoxins (BoNTs), the most poisonous substances known to date, is essential for studies of medical applications of BoNTs and detection of poisoned food, as well as for response to potential bioterrorist threats. Currently, the most common method of BoNT detection is the mouse bioassay. While this assay is sensitive, it is slow, quite expensive, has limited throughput and requires sacrificing animals. Herein, we discuss and compare recently developed alternative in vitro detection methods and assess their ability to supplement or replace the mouse bioassay in the analysis of complex matrix samples.
Collapse
Affiliation(s)
- Petr Čapek
- Department of Chemistry, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, CA 92037, USA;
| | - Tobin J. Dickerson
- Department of Chemistry and Worm Institute for Research and Medicine, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, CA 92037, USA
- Author to whom correspondence should be addressed; ; Tel.: +1-858-784-2522; Fax: +1-858-784-2590
| |
Collapse
|
42
|
Čapek P, Dickerson TJ. Sensing the deadliest toxin: technologies for botulinum neurotoxin detection. Toxins (Basel) 2010; 2:24-53. [PMID: 22069545 PMCID: PMC3206617 DOI: 10.3390/toxins2020024] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2009] [Revised: 12/17/2009] [Accepted: 12/22/2009] [Indexed: 11/16/2022] Open
Abstract
Sensitive and rapid detection of botulinum neurotoxins (BoNTs), the most poisonous substances known to date, is essential for studies of medical applications of BoNTs and detection of poisoned food, as well as for response to potential bioterrorist threats. Currently, the most common method of BoNT detection is the mouse bioassay. While this assay is sensitive, it is slow, quite expensive, has limited throughput and requires sacrificing animals. Herein, we discuss and compare recently developed alternative in vitro detection methods and assess their ability to supplement or replace the mouse bioassay in the analysis of complex matrix samples.
Collapse
Affiliation(s)
- Petr Čapek
- Department of Chemistry, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, CA 92037, USA;
| | - Tobin J. Dickerson
- Department of Chemistry and Worm Institute for Research and Medicine, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, CA 92037, USA
| |
Collapse
|
43
|
Sun S, Ossandon M, Kostov Y, Rasooly A. Lab-on-a-chip for botulinum neurotoxin a (BoNT-A) activity analysis. LAB ON A CHIP 2009; 9:3275-81. [PMID: 19865736 PMCID: PMC2849933 DOI: 10.1039/b912097a] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
A Lab-on-a-chip (LOC) was designed, fabricated and tested for the in vitro detection of botulinum neurotoxin serotype A (BoNT-A) activity using an assay that measures cleavage of a fluorophore-tagged peptide substrate specific for BoNT-A (SNAP-25) by the toxin light chain (LcA). LcA cleavage was detected by Förster Resonance Energy Transfer (FRET) fluorescence. FRET fluorescence was measured by a newly developed portable charge-coupled device (CCD) fluorescent detector equipped with multi-wavelength light-emitting diodes (LED) illumination. An eight V-junction microchannel device for BoNTs activity assays was constructed using Laminated Object Manufacturing (LOM) technology. The six-layer device was fabricated with a Poly(methyl methacrylate (PMMA) core and five polycarbonate (PC) layers micromachined by CO2 laser. The LOC is operated by syringe and is equipped with reagents, sample wells, reaction wells, diffusion traps (to avoid cross contamination among channels) and waste reservoirs. The system was detected LcA at concentrations as low as 0.5 nM, which is the reported sensitivity of the SNAP-25 in vitro cleavage assay. Combined with our CCD detector, the simple point of care system enables the detection of BoNTs activity and may be useful for the performance of other complex medical assays without a laboratory. This approach may realize the potential to enhance the quality of health care delivery for underserved populations.
Collapse
Affiliation(s)
- Steven Sun
- Division of Biology, Office of Science and Engineering Laboratories, FDA, NIH/NCI, Silver Spring, MD, 20993, USA6130 Executive Blvd. EPN, Room 6035A Rockville, 20852; Fax: (+301) 402-7819; Tel: (+301) 402-4185
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD, 21250
| | - Miguel Ossandon
- Cancer Diagnosis Program, National Cancer Institute, Rockville, MD, 20892
| | - Yordan Kostov
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD, 21250
| | - Avraham Rasooly
- Division of Biology, Office of Science and Engineering Laboratories, FDA, NIH/NCI, Silver Spring, MD, 20993, USA6130 Executive Blvd. EPN, Room 6035A Rockville, 20852; Fax: (+301) 402-7819; Tel: (+301) 402-4185
- Cancer Diagnosis Program, National Cancer Institute, Rockville, MD, 20892
| |
Collapse
|
44
|
Yang M, Kostov Y, Bruck HA, Rasooly A. Gold nanoparticle-based enhanced chemiluminescence immunosensor for detection of Staphylococcal Enterotoxin B (SEB) in food. Int J Food Microbiol 2009; 133:265-71. [PMID: 19540011 DOI: 10.1016/j.ijfoodmicro.2009.05.029] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2008] [Revised: 05/26/2009] [Accepted: 05/27/2009] [Indexed: 10/20/2022]
Abstract
Staphylococcal enterotoxins (SEs) are major cause of foodborne diseases, so sensitive detection (<1 ng/ml) methods are needed for SE detection in food. The surface area, geometric and physical properties of gold nanoparticles make them well-suited for enhancing interactions with biological molecules in assays. To take advantage of the properties of gold nanoparticles for immunodetection, we have developed a gold nanoparticle-based enhanced chemiluminescence (ECL) immunosensor for detection of Staphylococcal Enterotoxin B (SEB) in food. Anti-SEB primary antibodies were immobilized onto a gold nanoparticle surface through physical adsorption and then the antibody-gold nanoparticle mixture was immobilized onto a polycarbonate surface. SEB was detected by a "sandwich-type" ELISA assay on the polycarbonate surface with a secondary antibody and ECL detection. The signal from ECL was read using a point-of-care detector based on a cooled charge-coupled device (CCD) sensor or a plate reader. The system was used to test for SEB in buffer and various foods (mushrooms, tomatoes, and baby food meat). The limit of detection was found to be approximately 0.01 ng/mL, which is approximately 10 times more sensitive than traditional ELISA. The gold nanoparticles were relatively easy to use for antibody immobilization because of their physical adsorption mechanism; no other reagents were required for immobilization. The use of our simple and inexpensive detector combined with the gold nanoparticle-based ECL method described here is adaptable to simplify and increase sensitivity of any immunological assay and for point-of-care diagnostics.
Collapse
Affiliation(s)
- Minghui Yang
- Center for Advanced Sensor Technology, University of Maryland Baltimore County, MD 21250, USA
| | | | | | | |
Collapse
|
45
|
Sapsford KE, Francis J, Sun S, Kostov Y, Rasooly A. Miniaturized 96-well ELISA chips for staphylococcal enterotoxin B detection using portable colorimetric detector. Anal Bioanal Chem 2009; 394:499-505. [PMID: 19290511 DOI: 10.1007/s00216-009-2730-z] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2009] [Revised: 02/20/2009] [Accepted: 02/23/2009] [Indexed: 10/21/2022]
|