1
|
Xu K, Wu X. Recent development on nanomaterial-based biosensors for identifying thyroid tumor biomarkers. Biotechnol Appl Biochem 2024. [PMID: 38961530 DOI: 10.1002/bab.2632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 06/17/2024] [Indexed: 07/05/2024]
Abstract
The incidence of thyroid tumors has been increasing yearly over the past decade, making it the fourth highest tumor in women. This places various biological burdens on those affected. Currently, thyroid tumors are primarily diagnosed using percutaneous fine needle aspiration and ultrasound. However, these methods are complex, expensive, and less accurate, and they may fail to detect some thyroid nodules. As an alternative, researchers are focusing on blood-based biomarkers in addition to the traditional diagnostic methods, assisted predominantly by nanomaterials. Early identification of thyroid cancer is crucial as it is highly treatable. Various sensing systems have been developed using nanomaterial-mediated approaches to enhance the detection system. Nanomaterials are effectively applied in biosensors for surface functionalization and are conjugated with biomolecules to improve the interaction with the target analyte. This review discusses nanomaterial-assisted thyroid tumor detection, with a special focus on nanomaterial-based biosensors.
Collapse
Affiliation(s)
- Kun Xu
- Department of Geriatrics, Second Hospital of Lanzhou University, Lanzhou, China
| | - XiaoLu Wu
- Department of Medical, Second Hospital of Lanzhou University, Lanzhou, China
| |
Collapse
|
2
|
Lab-on-a-chip systems for cancer biomarker diagnosis. J Pharm Biomed Anal 2023; 226:115266. [PMID: 36706542 DOI: 10.1016/j.jpba.2023.115266] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 01/20/2023] [Accepted: 01/20/2023] [Indexed: 01/22/2023]
Abstract
Lab-on-a-chip (LOC) or micro total analysis system is one of the microfluidic technologies defined as the adaptation, miniaturization, integration, and automation of analytical laboratory procedures into a single instrument or "chip". In this article, we review developments over the past five years in the application of LOC biosensors for the detection of different types of cancer. Microfluidics encompasses chemistry and biotechnology skills and has revolutionized healthcare diagnosis. Superior to traditional cell culture or animal models, microfluidic technology has made it possible to reconstruct functional units of organs on chips to study human diseases such as cancer. LOCs have found numerous biomedical applications over the past five years, including integrated bioassays, cell analysis, metabolomics, drug discovery and delivery systems, tissue and organ physiology and disease modeling, and personalized medicine. This review provides an overview of the latest developments in microfluidic-based cancer research, with pros, cons, and prospects.
Collapse
|
3
|
High-performance biosensor using a sandwich assay via antibody-conjugated gold nanoparticles and fiber-optic localized surface plasmon resonance. Anal Chim Acta 2022; 1213:339960. [DOI: 10.1016/j.aca.2022.339960] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 05/16/2022] [Accepted: 05/17/2022] [Indexed: 11/24/2022]
|
4
|
Maeno H, Wong PF, AbuBakar S, Yang M, Sam SS, Jamil-Abd J, Shunmugarajoo A, Mustafa M, Said RM, Mageswaren E, Azmel A, Mat Jelani A. A 3D Microfluidic ELISA for the Detection of Severe Dengue: Sensitivity Improvement and Vroman Effect Amelioration by EDC-NHS Surface Modification. MICROMACHINES 2021; 12:mi12121503. [PMID: 34945351 PMCID: PMC8715748 DOI: 10.3390/mi12121503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 11/20/2021] [Accepted: 11/29/2021] [Indexed: 11/16/2022]
Abstract
Serum is commonly used as a specimen in immunoassays but the presence of heterophilic antibodies can potentially interfere with the test results. Previously, we have developed a microfluidic device called: 3D Stack for enzyme-linked immunosorbent assay (ELISA). However, its evaluation was limited to detection from a single protein solution. Here, we investigated the sensitivity of the 3D Stack in detecting a severe dengue biomarker—soluble CD163 (sCD163)—within the serum matrix. To determine potential interactions with serum matrix, a spike-and-recovery assay was performed, using 3D Stacks with and without surface modification by an EDC–NHS (N-ethyl-N′-(3-(dimethylamino)propyl)carbodiimide/N-hydroxysuccinimide) coupling. Without surface modification, a reduced analyte recovery in proportion to serum concentration was observed because of the Vroman effect, which resulted in competitive displacement of coated capture antibodies by serum proteins with stronger binding affinities. However, EDC–NHS coupling prevented antibody desorption and improved the sensitivity. Subsequent comparison of sCD163 detection using a 3D Stack with EDC–NHS coupling and conventional ELISA in dengue patients’ sera revealed a high correlation (R = 0.9298, p < 0.0001) between the two detection platforms. Bland–Altman analysis further revealed insignificant systematic error between the mean differences of the two methods. These data suggest the potentials of the 3D Stack for further development as a detection platform.
Collapse
Affiliation(s)
- Hinata Maeno
- Department of System Design, Tokyo Metropolitan University, Tokyo 191-0065, Japan;
| | - Pooi-Fong Wong
- Department of Pharmacology, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia;
| | - Sazaly AbuBakar
- Tropical Infectious Diseases Research and Educational Centre (TIDREC), University of Malaya, Kuala Lumpur 50603, Malaysia; (S.A.); (S.-S.S.); (J.J.-A.)
- WHO Collaborating Centre for Arbovirus Reference and Research (Dengue and Severe Dengue) MAA-12, University of Malaya, Kuala Lumpur 50603, Malaysia
- Medical Department, Tengku Ampuan Rahimah Hospital, Klang 41200, Malaysia; (A.S.); (E.M.); (A.A.)
| | - Ming Yang
- Department of System Design, Tokyo Metropolitan University, Tokyo 191-0065, Japan;
- Correspondence:
| | - Sing-Sin Sam
- Tropical Infectious Diseases Research and Educational Centre (TIDREC), University of Malaya, Kuala Lumpur 50603, Malaysia; (S.A.); (S.-S.S.); (J.J.-A.)
- WHO Collaborating Centre for Arbovirus Reference and Research (Dengue and Severe Dengue) MAA-12, University of Malaya, Kuala Lumpur 50603, Malaysia
| | - Juraina Jamil-Abd
- Tropical Infectious Diseases Research and Educational Centre (TIDREC), University of Malaya, Kuala Lumpur 50603, Malaysia; (S.A.); (S.-S.S.); (J.J.-A.)
- WHO Collaborating Centre for Arbovirus Reference and Research (Dengue and Severe Dengue) MAA-12, University of Malaya, Kuala Lumpur 50603, Malaysia
| | - Anusha Shunmugarajoo
- Medical Department, Tengku Ampuan Rahimah Hospital, Klang 41200, Malaysia; (A.S.); (E.M.); (A.A.)
| | - Mahiran Mustafa
- Medical Department, Raja Perempuan Zainab II Hospital, Kota Bharu 15200, Malaysia; (M.M.); (A.M.J.)
| | - Rosaida Md Said
- Medical Department, Ampang Hospital, Ampang 68000, Malaysia;
| | - Eashwary Mageswaren
- Medical Department, Tengku Ampuan Rahimah Hospital, Klang 41200, Malaysia; (A.S.); (E.M.); (A.A.)
| | - Azureen Azmel
- Medical Department, Tengku Ampuan Rahimah Hospital, Klang 41200, Malaysia; (A.S.); (E.M.); (A.A.)
| | - Anilawati Mat Jelani
- Medical Department, Raja Perempuan Zainab II Hospital, Kota Bharu 15200, Malaysia; (M.M.); (A.M.J.)
| |
Collapse
|
5
|
Tatarko M, Spagnolo S, Oravczová V, Süle J, Hun M, Hucker A, Hianik T. Changes of Viscoelastic Properties of Aptamer-Based Sensing Layers Following Interaction with Listeria innocua. SENSORS (BASEL, SWITZERLAND) 2021; 21:5585. [PMID: 34451028 PMCID: PMC8402281 DOI: 10.3390/s21165585] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 08/13/2021] [Accepted: 08/18/2021] [Indexed: 02/06/2023]
Abstract
A multiharmonic quartz crystal microbalance (QCM) has been applied to study the viscoelastic properties of the aptamer-based sensing layers at the surface of a QCM transducer covered by neutravidin following interaction with bacteria Listeria innocua. Addition of bacteria in the concentration range 5 × 103-106 CFU/mL resulted in a decrease of resonant frequency and in an increase of dissipation. The frequency decrease has been lower than one would expect considering the dimension of the bacteria. This can be caused by lower penetration depth of the acoustics wave (approximately 120 nm) in comparison with the thickness of the bacterial layer (approximately 500 nm). Addition of E. coli at the surface of neutravidin as well as aptamer layers did not result in significant changes in frequency and dissipation. Using the Kelvin-Voight model the analysis of the viscoelastic properties of the sensing layers was performed and several parameters such as penetration depth, Γ, viscosity coefficient, η, and shear modulus, μ, were determined following various modifications of QCM transducer. The penetration depth decreased following adsorption of the neutravidin layer, which is evidence of the formation of a rigid protein structure. This value did not change significantly following adsorption of aptamers and Listeria innocua. Viscosity coefficient was higher for the neutravidin layer in comparison with the naked QCM transducer in a buffer. However, a further increase of viscosity coefficient took place following attachment of aptamers suggesting their softer structure. The interaction of Listeria innocua with the aptamer layer resulted in slight decrease of viscosity coefficient. The shearing modulus increased for the neutravidin layer and decreased following aptamer adsorption, while a slight increase of µ was observed after the addition of Listeria innocua.
Collapse
Affiliation(s)
- Marek Tatarko
- Department of Nuclear Physics and Biophysics, Faculty of Mathematics, Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F1, 842 48 Bratislava, Slovakia; (M.T.); (S.S.); (V.O.)
| | - Sandro Spagnolo
- Department of Nuclear Physics and Biophysics, Faculty of Mathematics, Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F1, 842 48 Bratislava, Slovakia; (M.T.); (S.S.); (V.O.)
| | - Veronika Oravczová
- Department of Nuclear Physics and Biophysics, Faculty of Mathematics, Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F1, 842 48 Bratislava, Slovakia; (M.T.); (S.S.); (V.O.)
| | - Judit Süle
- Hungarian Dairy Research Institute Ltd., 9200 Mosonmagyaróvár, Hungary; (J.S.); (M.H.); (A.H.)
| | - Milan Hun
- Hungarian Dairy Research Institute Ltd., 9200 Mosonmagyaróvár, Hungary; (J.S.); (M.H.); (A.H.)
| | - Attila Hucker
- Hungarian Dairy Research Institute Ltd., 9200 Mosonmagyaróvár, Hungary; (J.S.); (M.H.); (A.H.)
| | - Tibor Hianik
- Department of Nuclear Physics and Biophysics, Faculty of Mathematics, Physics and Informatics, Comenius University in Bratislava, Mlynská dolina F1, 842 48 Bratislava, Slovakia; (M.T.); (S.S.); (V.O.)
| |
Collapse
|
6
|
de Moraes MOS, de Moraes Segundo JDDP, Paula MMDS, Sales MGF, Brito WR. Highly sensitive electrochemical immunosensor using a protein-polyvinylidene fluoride nanocomposite for human thyroglobulin. Bioelectrochemistry 2021; 142:107888. [PMID: 34325091 DOI: 10.1016/j.bioelechem.2021.107888] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 07/12/2021] [Accepted: 07/13/2021] [Indexed: 01/16/2023]
Abstract
The highly sensitive detection of serum thyroglobulin (Tg) is essential in the post-treatment follow-up of patients with differentiated thyroid cancer undergoing total or partial thyroidectomy and radioactive iodine ablation and requires sensitive, accurate and stable methods. This work proposes an electrochemical immunosensor for the detection of serum Tg antigen, making use of innovative nanocomposites including polyvinylidene fluoride (PVDF) microparticles coated with streptavidin (MP) and gold nanoparticles (AuNPs). The functionalized polymer matrices were characterized by UV-Vis, FTIR, XPS, SEM, dynamic light scattering, and free surface energy. Immobilization of biotin-labeled anti-thyroglobulin monoclonal antibodies was achieved by binding these to the polymer nanocomposite via streptavidin proteins. The analytical response was measured in quintuplicate and had a linear profile from 2.0 to 10.0 ng/mL Tg, with r2 of 0.985. The limits of detection and quantification were excellent, equal to 0.015 and 0.047 ng/mL, respectively. In addition, the recovery factor was equal to 95.4% (1.0 ng/mL Tg). Overall, the innovative polymer-based nanocomposite used herein enabled the production of an electrochemical-based immunosensor with excellent sensitivity, selectivity, and reproducibility. It evidenced the remarkable potential of determining low levels of Tg in in vitro assays, thereby suggesting that it may be considered for the analyzes of serum patients.
Collapse
Affiliation(s)
- Maria Oneide Silva de Moraes
- LABEL, Department of Chemistry, Federal University of Amazonas, Manaus, Amazonas 69067-005, Brazil; Thematic Laboratory of Microscopy and Nanotechnology, National Institute of Amazonian Research Manaus, Amazonas 69067-001, Brazil.
| | | | | | - Maria Goreti Ferreira Sales
- BioMark@UC, Department of Chemical Engineering, Faculty of Sciences and Technology, University of Coimbra, Coimbra 3030-790, Portugal
| | - Walter Ricardo Brito
- LABEL, Department of Chemistry, Federal University of Amazonas, Manaus, Amazonas 69067-005, Brazil.
| |
Collapse
|
7
|
Wang Y, Sun X, Gopinath SCB, Saheed MSM, Wang X. Thyroglobulin determination on silane-antibody functionalized interdigitated dielectrode surface to diagnose thyroid tumor. Biotechnol Appl Biochem 2021; 69:376-382. [PMID: 33538049 DOI: 10.1002/bab.2116] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Accepted: 01/06/2021] [Indexed: 12/13/2022]
Abstract
Thyroid cancer appears in endocrine glands and specific to thyroid glands has been reported widely. This work was targeted to identify and quantify thyroglobulin by using antithyroglobulin antibody complexed silane surface on interdigitated electrode (IDE) sensing surface. (3-Aminopropyl)triethoxysilane linker was used to make silane-coupling with antibody and attached on the hydroxylated IDE. This electroanalytical IDE revealed the dose-dependent responses with thyroglobulin concentrations. By getting increments with the thyroglobulin concentrations, the current responses were enhanced concomitantly and the thyroglobulin detection limit was noted as 1 pM on the linear curve [y = 0.1311x + 0.5386; R² = 0.9707] with the sensitivity at lower picomolar range. Moreover, the control experiments with thyroid peroxidase and nonimmune antibody cannot yield any response of current, confirming the specific detection of thyroglobulin. This research set-up is useful to determine and quantify the thyroglobulin and diagnose thyroid cancer.
Collapse
Affiliation(s)
- Yujie Wang
- Department of Clinical Laboratory, Qingdao Municipal Hospital, Qingdao, Shandong, People's Republic of China
| | - Xia Sun
- Department of Clinical Laboratory, Qingdao Women and Children's Hospital, Qingdao, Shandong, People's Republic of China
| | - Subash C B Gopinath
- Faculty of Chemical Engineering Technology, Universiti Malaysia Perlis, Arau, Perlis, 02600, Malaysia.,Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, Kangar, Perlis, 01000, Malaysia
| | - Mohamed Shuaib Mohamed Saheed
- Department of Mechanical Engineering, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia.,Centre of Innovative Nanostructure & Nanodevices, Universiti Teknologi PETRONAS, 32610 Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Xiaofei Wang
- Department of Oncology, Qingdao Municipal Hospital, Qingdao, Shandong, People's Republic of China
| |
Collapse
|
8
|
Adsorption and Conformation Behavior of Lysozyme on a Gold Surface Determined by QCM-D, MP-SPR, and FTIR. Int J Mol Sci 2021; 22:ijms22031322. [PMID: 33525751 PMCID: PMC7865459 DOI: 10.3390/ijms22031322] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 01/20/2021] [Accepted: 01/25/2021] [Indexed: 11/21/2022] Open
Abstract
The physicochemical properties of protein layers at the solid–liquid interface are essential in many biological processes. This study aimed to link the structural analysis of adsorbed lysozyme at the water/gold surface at pH 7.5 in a wide range of concentrations. Particular attention was paid to the protein’s structural stability and the hydration of the protein layers formed at the interface. Complementary methods such as multi-parameter surface plasmon resonance (MP-SPR), quartz crystal microbalance with energy dissipation (QCM-D), and infrared spectroscopy (FTIR) were used for this purpose. The MP-SPR and QCM-D studies showed that, during the formation of a monolayer on the gold surface, the molecules’ orientation changes from side-on to end-on. In addition, bilayer formation is observed when adsorbing in the high-volume concentration range >500 ppm. The degree of hydration of the monolayer and bilayer varies depending on the degree of surface coverage. The hydration of the system decreases with filling the layer in both the monolayer and the bilayer. Hydration for the monolayer varies in the range of 50–70%, because the bilayer is much higher than 80%. The degree of hydration of the adsorption layer has a crucial influence on the protein layers’ viscoelastic properties. In general, an increase in the filling of a layer is characterized by a rise in its rigidity. The use of infrared spectroscopy allowed us to determine the changes taking place in the secondary structure of lysozyme due to its interaction with the gold surface. Upon adsorption, the content of II-structures corresponding to β-turn and random lysozyme structures increases, with a simultaneous decrease in the content of the β-sheet. The increase in the range of β-turn in the structure determines the lysozyme structure’s stability and prevents its aggregation.
Collapse
|
9
|
Peng L, Lin CJ, Shi L, Cai F. Magnetic mesoporous CoFe 2O 4 labels reacted with TMB for use in a sandwiched photothermal immunoassay for thyroglobulin. NEW J CHEM 2021. [DOI: 10.1039/d1nj04897j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
An innovative photothermal immunoassay with a sandwich-type immunoreaction mode was designed for the sensitive screening of thyroglobulin on capture antibody-coated microtiter plates using a handheld digital thermometer as the readout device.
Collapse
Affiliation(s)
- Lin Peng
- Xiamen Changgung Hospital, Xiamen 361028, Fujian, People's Republic of China
| | - Chi Jui Lin
- Xiamen Changgung Hospital, Xiamen 361028, Fujian, People's Republic of China
| | - Lei Shi
- Xiamen Changgung Hospital, Xiamen 361028, Fujian, People's Republic of China
| | - Fan Cai
- College of Life Sciences, Fujian Normal University, Fuzhou 350117, Fujian, People's Republic of China
| |
Collapse
|
10
|
Selection and characterization of an ssDNA aptamer against thyroglobulin. Talanta 2020; 223:121690. [PMID: 33303143 DOI: 10.1016/j.talanta.2020.121690] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 09/14/2020] [Accepted: 09/19/2020] [Indexed: 02/07/2023]
Abstract
Thyroglobulin (Tg) is a significant biomarker for the diagnose and postoperative monitoring of differentiated thyroid cancer, and its recognition is urgent due to the rising prevalence. In this study, an ssDNA aptamer against Tg was obtained by capillary electrophoresis-systematic evolution of ligands via exponential enrichment (CE-SELEX). Under the optimized conditions, the sub-library was enriched well through two selection rounds. After high-throughput sequencing, eight candidate sequences were picked out and their affinities towards Tg were observed not in accordance with the order of their frequencies, whereas sequence homology played a significant role in binding affinity. The high-affinity sequence Seq.T-2 with a dissociation constant (Kd) of 3.18 μM was finally selected as the aptamer, and its affinity was confirmed qualitatively by gold nanoparticles colorimetric and quantitatively by thin film interferometry (Kd, 4.51 nM). Besides, molecular docking and dynamics simulation were performed for their binding sites prediction and affinity confirmation. Furthermore, the aptamer was applied for Tg detection, which delivered a detection limit of 5.0 nM as well as with good selectivity, and showed a good linear relationship within a wide range of 10 nM-6.4 μM of Tg spiked into the serum matrix. This study first reported Tg's aptamer which also exhibited the potential in real applications.
Collapse
|
11
|
Tan JYB, Yoon BK, Ma GJ, Sut TN, Cho NJ, Jackman JA. Unraveling How Ethanol-Induced Conformational Changes Affect BSA Protein Adsorption onto Silica Surfaces. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:9215-9224. [PMID: 32654494 DOI: 10.1021/acs.langmuir.0c01478] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Protein adsorption at solid-liquid interfaces is highly relevant to a wide range of applications such as biosensors, drug delivery, and pharmaceuticals. Understanding how protein conformation in bulk solution impacts adsorption behavior is fundamentally important and could also lead to the development of improved protein-based coatings. To date, relevant studies have been conducted in aqueous solutions, while it remains largely unknown how organic solvents and more specifically solvent-induced conformational changes might influence protein adsorption. Herein, using the quartz crystal microbalance-dissipation (QCM-D) and localized surface plasmon resonance (LSPR) techniques, we systematically investigated the real-time adsorption behavior of bovine serum albumin (BSA) protein onto silica surfaces in different water-ethanol mixtures ranging from 0 to 60% (v/v) ethanol. The results showed that there was greater protein adsorption at higher ethanol fractions in the 10-30% range, while more complex adsorption profiles were observed in the 40-60% range. The combination of QCM-D and LSPR measurements led us to further identify specific cases in water-ethanol mixtures where washing steps caused densification of the adsorbed protein layer as opposed to typical desorption of weakly adsorbed molecules in aqueous conditions. We discuss mechanistic factors that drive these overall adsorption trends by taking into account how ethanol fraction affects BSA conformation in bulk solution. Together, our findings demonstrate that BSA proteins can adsorb onto silica surfaces across a wide range of water-ethanol mixture conditions, while specific adsorption profiles depended on the ethanol fraction in a manner closely linked to solution-phase conformational properties.
Collapse
Affiliation(s)
- Jia Ying Brenda Tan
- School of Chemical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore
| | - Bo Kyeong Yoon
- School of Chemical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Gamaliel Junren Ma
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore
| | - Tun Naw Sut
- School of Chemical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore
| | - Nam-Joon Cho
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 Singapore
| | - Joshua A Jackman
- School of Chemical Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea
| |
Collapse
|
12
|
Fang D, Huang Y, Zhang S, Dai H, Hong Z, Lin Y. Versatile NiCo2O4 nanosheets hybrids-based label-free immunosensor for thyroglobulin using photothermal amplification. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.135790] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
13
|
Fu Y, Ji H. Cytomorphology-based microchip with contour extraction processing for bioparticle analysis. Electrophoresis 2018; 40:1195-1201. [PMID: 30387160 DOI: 10.1002/elps.201800271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2018] [Revised: 10/15/2018] [Accepted: 10/28/2018] [Indexed: 11/08/2022]
Abstract
In this paper, we demonstrated an integrated digital image processing framework that is training-free for high throughput beads or biological cells detection and enumeration by the bead aggregation splitting algorithm. By making contour extraction processing, the aggregated beads can be clearly split for precise counting. It can be potentially embedded on-chip in a miniaturized medical equipment to automatically adjust illumination condition and de-noise. This study demonstrates that the existing hematological analysis can be updated from manual classification and counting by high-speed and precise machine-based programs.
Collapse
Affiliation(s)
- Yusheng Fu
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, P. R. China
| | - Hong Ji
- School of Information and Communication Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, P. R. China
| |
Collapse
|
14
|
Perumal G, Ayyagari A, Chakrabarti A, Kannan D, Pati S, Grewal HS, Mukherjee S, Singh S, Arora HS. Friction Stir Processing of Stainless Steel for Ascertaining Its Superlative Performance in Bioimplant Applications. ACS APPLIED MATERIALS & INTERFACES 2017; 9:36615-36631. [PMID: 28972737 DOI: 10.1021/acsami.7b11064] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Substrate-cell interactions for a bioimplant are driven by substrate's surface characteristics. In addition, the performance of an implant and resistance to degradation are primarily governed by its surface properties. A bioimplant typically degrades by wear and corrosion in the physiological environment, resulting in metallosis. Surface engineering strategies for limiting degradation of implants and enhancing their performance may reduce or eliminate the need for implant removal surgeries and the associated cost. In the current study, we tailored the surface properties of stainless steel using submerged friction stir processing (FSP), a severe plastic deformation technique. FSP resulted in significant microstructural refinement from 22 μm grain size for the as-received alloy to 0.8 μm grain size for the processed sample with increase in hardness by nearly 1.5 times. The wear and corrosion behavior of the processed alloy was evaluated in simulated body fluid. The processed sample demonstrated remarkable improvement in both wear and corrosion resistance, which is explained by surface strengthening and formation of a highly stable passive layer. The methylthiazol tetrazolium assay demonstrated that the processed sample is better in supporting cell attachment, proliferation with minimal toxicity, and hemolysis. The athrombogenic characteristic of the as-received and processed samples was evaluated by fibrinogen adsorption and platelet adhesion via the enzyme-linked immunosorbent assay and lactate dehydrogenase assay, respectively. The processed sample showed less platelet and fibrinogen adhesion compared with the as-received alloy, signifying its high thromboresistance. The current study suggests friction stir processing to be a versatile toolbox for enhancing the performance and reliability of currently used bioimplant materials.
Collapse
Affiliation(s)
| | - A Ayyagari
- Department of Materials Science and Engineering, University of North Texas , Denton, Texas 76203, United States
| | | | | | | | | | - S Mukherjee
- Department of Materials Science and Engineering, University of North Texas , Denton, Texas 76203, United States
| | - S Singh
- Special Center for Molecular Medicine, Jawaharlal Nehru University , New Delhi 110067, India
| | | |
Collapse
|
15
|
Perez-Gonzalez VH, Gallo-Villanueva RC, Camacho-Leon S, Gomez-Quiñones JI, Rodriguez-Delgado JM, Martinez-Chapa SO. Emerging microfluidic devices for cancer cells/biomarkers manipulation and detection. IET Nanobiotechnol 2016; 10:263-275. [PMID: 27676373 PMCID: PMC8676477 DOI: 10.1049/iet-nbt.2015.0060] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 12/09/2015] [Accepted: 12/15/2015] [Indexed: 01/04/2023] Open
Abstract
Circulating tumour cells (CTCs) are active participants in the metastasis process and account for ∼90% of all cancer deaths. As CTCs are admixed with a very large amount of erythrocytes, leukocytes, and platelets in blood, CTCs are very rare, making their isolation, capture, and detection a major technological challenge. Microfluidic technologies have opened-up new opportunities for the screening of blood samples and the detection of CTCs or other important cancer biomarker-proteins. In this study, the authors have reviewed the most recent developments in microfluidic devices for cells/biomarkers manipulation and detection, focusing their attention on immunomagnetic-affinity-based devices, dielectrophoresis-based devices, surface-plasmon-resonance microfluidic sensors, and quantum-dots-based sensors.
Collapse
Affiliation(s)
- Victor Hugo Perez-Gonzalez
- School of Engineering and Sciences, Tecnologico de Monterrey, Avenue Eugenio Garza Sada 2501 Sur, Monterrey, Mexico
| | | | - Sergio Camacho-Leon
- School of Engineering and Sciences, Tecnologico de Monterrey, Avenue Eugenio Garza Sada 2501 Sur, Monterrey, Mexico
| | - Jose Isabel Gomez-Quiñones
- School of Biotechnology and Health Sciences, Tecnologico de Monterrey, Avenue Eugenio Garza Sada 2501 Sur, Monterrey, Mexico
| | | | - Sergio Omar Martinez-Chapa
- School of Engineering and Sciences, Tecnologico de Monterrey, Avenue Eugenio Garza Sada 2501 Sur, Monterrey, Mexico.
| |
Collapse
|
16
|
Quero G, Consales M, Severino R, Vaiano P, Boniello A, Sandomenico A, Ruvo M, Borriello A, Diodato L, Zuppolini S, Giordano M, Nettore IC, Mazzarella C, Colao A, Macchia PE, Santorelli F, Cutolo A, Cusano A. Long period fiber grating nano-optrode for cancer biomarker detection. Biosens Bioelectron 2016; 80:590-600. [DOI: 10.1016/j.bios.2016.02.021] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Revised: 01/27/2016] [Accepted: 02/08/2016] [Indexed: 10/22/2022]
|
17
|
An enhanced SPR immunosensing platform for human IgG based on the use of silver nanocubes and carboxy-functionalized graphene oxide. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1853-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
18
|
Wang R, Wang W, Ren H, Chae J. Detection of copper ions in drinking water using the competitive adsorption of proteins. Biosens Bioelectron 2014; 57:179-85. [DOI: 10.1016/j.bios.2014.01.056] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2013] [Revised: 01/27/2014] [Accepted: 01/28/2014] [Indexed: 10/25/2022]
|
19
|
Zhang Y, Yang D, Weng L, Wang L. Early lung cancer diagnosis by biosensors. Int J Mol Sci 2013; 14:15479-509. [PMID: 23892596 PMCID: PMC3759869 DOI: 10.3390/ijms140815479] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2013] [Revised: 06/29/2013] [Accepted: 07/04/2013] [Indexed: 12/20/2022] Open
Abstract
Lung cancer causes an extreme threat to human health, and the mortality rate due to lung cancer has not decreased during the last decade. Prognosis or early diagnosis could help reduce the mortality rate. If microRNA and tumor-associated antigens (TAAs), as well as the corresponding autoantibodies, can be detected prior to clinical diagnosis, such high sensitivity of biosensors makes the early diagnosis and prognosis of cancer realizable. This review provides an overview of tumor-associated biomarker identifying methods and the biosensor technology available today. Laboratorial researches utilizing biosensors for early lung cancer diagnosis will be highlighted.
Collapse
Affiliation(s)
- Yuqian Zhang
- Key Laboratory for Organic Electronics & Information Displays (KLOEID) and Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing 210023, China; E-Mails: (Y.Z.); (D.Y.)
| | - Dongliang Yang
- Key Laboratory for Organic Electronics & Information Displays (KLOEID) and Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing 210023, China; E-Mails: (Y.Z.); (D.Y.)
| | - Lixing Weng
- College of Geography and Biological Information, Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing 210023, China
| | - Lianhui Wang
- Key Laboratory for Organic Electronics & Information Displays (KLOEID) and Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing 210023, China; E-Mails: (Y.Z.); (D.Y.)
| |
Collapse
|
20
|
Penchovsky R. Programmable and automated bead-based microfluidics for versatile DNA microarrays under isothermal conditions. LAB ON A CHIP 2013; 13:2370-2380. [PMID: 23645132 DOI: 10.1039/c3lc50208b] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Advances in modern genomic research depend heavily on applications of various devices for automated high- or ultra-throughput arrays. Micro- and nanofluidics offer possibilities for miniaturization and integration of many different arrays onto a single device. Therefore, such devices are becoming a platform of choice for developing analytical instruments for modern biotechnology. This paper presents an implementation of a bead-based microfluidic platform for fully automated and programmable DNA microarrays. The devices are designed to work under isothermal conditions as DNA immobilization and hybridization transfer are performed under steady temperature using reversible pH alterations of reaction solutions. This offers the possibility for integration of more selection modules onto a single chip compared to maintaining a temperature gradient. This novel technology allows integration of many modules on a single reusable chip reducing the application cost. The method takes advantage of demonstrated high-speed DNA hybridization kinetics and denaturation on beads under flow conditions, high-fidelity of DNA hybridization, and small sample volumes are needed. The microfluidic devices are applied for a single nucleotide polymorphism analysis and DNA sequencing by synthesis without the need for fluorescent removal step. Apart from that, the microfluidic platform presented is applicable to many areas of modern biotechnology, including biosensor devices, DNA hybridization microarrays, molecular computation, on-chip nucleic acid selection, high-throughput screening of chemical libraries for drug discovery.
Collapse
Affiliation(s)
- Robert Penchovsky
- Department of Genetics, Faculty of Biology, Sofia University St. Kliment Ohridski, Sofia, Bulgaria.
| |
Collapse
|
21
|
Sardesai NP, Kadimisetty K, Faria R, Rusling JF. A microfluidic electrochemiluminescent device for detecting cancer biomarker proteins. Anal Bioanal Chem 2013; 405:3831-8. [PMID: 23307128 PMCID: PMC3610849 DOI: 10.1007/s00216-012-6656-5] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2012] [Revised: 11/21/2012] [Accepted: 12/12/2012] [Indexed: 12/22/2022]
Abstract
We describe an electrochemiluminescence (ECL) immunoarray incorporated into a prototype microfluidic device for highly sensitive protein detection and apply this system to accurate, sensitive measurements of prostate-specific antigen (PSA) and interleukin-6 (IL-6) in serum. The microfluidic system employed three molded polydimethylsiloxane (PDMS) channels on a conductive pyrolytic graphite chip (2.5 × 2.5 cm) inserted into a machined chamber and interfaced with a pump, switching valve, and sample injector. Each of the three PDMS channels encompasses three 3 μL analytical wells. Capture-antibody-decorated single-wall carbon nanotube forests are fabricated in the bottom of the wells. The antigen is captured by these antibodies on the well bottoms. Then, a RuBPY-silica-secondary antibody (Ab2) label is injected to bind to antigen on the array, followed by injection of sacrificial reductant tripropylamine (TPrA) to produce ECL. For detection, the chip is placed into an open-top ECL measuring cell, and the channels are in contact with electrolyte in the chamber. Potential applied at 0.95 V versus Ag/AgCl oxidizes TPrA to produce ECL by redox cycling the RuBPY species in the particles, and ECL light is measured by a charge-coupled device camera. This approach achieved ultralow detection limits of 100 fg mL(-1) for PSA (9 zeptomole) and 10 fg mL(-1) (1 zeptomole) for IL-6 in calf serum, a 10-25-fold improvement of a similar non-microfluidic array. PSA and IL-6 in synthetic cancer patient serum samples were detected in 1.1 h and results correlated well with single-protein enzyme-linked immunosorbent assays.
Collapse
Affiliation(s)
| | | | - Ronaldo Faria
- Department of Chemistry, University of Connecticut, Storrs, CT 06269 USA
- Departamento de Química, Universidade Federal de São Carlos, SP, Brazil
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT 06269 USA
- Department of Cell Biology, University of Connecticut Health Center, Farmington, CT 06032 USA
- Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269, USA
| |
Collapse
|
22
|
Powers AD, Palecek SP. Protein analytical assays for diagnosing, monitoring, and choosing treatment for cancer patients. JOURNAL OF HEALTHCARE ENGINEERING 2012; 3:503-534. [PMID: 25147725 DOI: 10.1260/2040-2295.3.4.503] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Cancer treatment is often hindered by inadequate methods for diagnosing the disease or insufficient predictive capacity regarding therapeutic efficacy. Targeted cancer treatments, including Bcr-Abl and EGFR kinase inhibitors, have increased survival for some cancer patients but are ineffective in other patients. In addition, many patients who initially respond to targeted inhibitor therapy develop resistance during the course of treatment. Molecular analysis of cancer cells has emerged as a means to tailor treatment to particular patients. While DNA analysis can provide important diagnostic information, protein analysis is particularly valuable because proteins are more direct mediators of normal and diseased cellular processes. In this review article, we discuss current and emerging protein assays for improving cancer treatment, including trends toward assay miniaturization and measurement of protein activity.
Collapse
Affiliation(s)
- Alicia D Powers
- Department of Chemical and Biological Engineering University of Wisconsin-Madison
| | - Sean P Palecek
- Department of Chemical and Biological Engineering University of Wisconsin-Madison
| |
Collapse
|
23
|
Lima RS, Piazzetta MHO, Gobbi AL, Rodrigues-Filho UP, Nascente PAP, Coltro WKT, Carrilho E. Contactless conductivity biosensor in microchip containing folic acid as bioreceptor. LAB ON A CHIP 2012; 12:1963-1966. [PMID: 22549415 DOI: 10.1039/c2lc40157f] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We report a glass/PDMS-based microfluidic biosensor that integrates contactless conductivity transduction and folic acid, a target for tumor biomarker, as a bioreceptor. The device presents relevant advantages such as direct determination--dismiss the use of redox mediators as in faradaic electrochemical techniques--and the absence of the known drawbacks related to the electrode-solution interface. Characterizations of the functionalization processes and chemical sensor are described in this communication.
Collapse
Affiliation(s)
- Renato S Lima
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, SP, Brazil
| | | | | | | | | | | | | |
Collapse
|
24
|
Rich RL, Myszka DG. Survey of the 2009 commercial optical biosensor literature. J Mol Recognit 2012; 24:892-914. [PMID: 22038797 DOI: 10.1002/jmr.1138] [Citation(s) in RCA: 83] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
We took a different approach to reviewing the commercial biosensor literature this year by inviting 22 biosensor users to serve as a review committee. They set the criteria for what to expect in a publication and ultimately decided to use a pass/fail system for selecting which papers to include in this year's reference list. Of the 1514 publications in 2009 that reported using commercially available optical biosensor technology, only 20% passed their cutoff. The most common criticism the reviewers had with the literature was that "the biosensor experiments could have been done better." They selected 10 papers to highlight good experimental technique, data presentation, and unique applications of the technology. This communal review process was educational for everyone involved and one we will not soon forget.
Collapse
Affiliation(s)
- Rebecca L Rich
- Center for Biomolecular Interaction Analysis, University of Utah, Salt Lake City, UT, USA
| | | |
Collapse
|
25
|
Qi ZM, Lu DF, Deng L, Matsuda N. Kinetics of Competitive Adsorption of β-Casein and Methylene Blue on Hydrophilic Glass. J Phys Chem A 2012; 116:2141-6. [DOI: 10.1021/jp211626m] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Zhi-mei Qi
- State Key Laboratory of Transducer
Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China
| | - Dan-feng Lu
- State Key Laboratory of Transducer
Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China
| | - Lin Deng
- State Key Laboratory of Transducer
Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China
| | - Naoki Matsuda
- Measurement Solution Research
Center, National Institute of Advanced Industrial Science and Technology, Tosu 841-0052, Japan
| |
Collapse
|
26
|
Choi S, Huang S, Li J, Chae J. Monitoring protein distributions based on patterns generated by protein adsorption behavior in a microfluidic channel. LAB ON A CHIP 2011; 11:3681-3688. [PMID: 21922107 DOI: 10.1039/c1lc20680j] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We report a unique monitoring technique of protein distributions based on distinctive patterns generated by protein adsorption behavior on a solid surface in a microfluidic channel. Bare gold and COOH-modified self-assembled monolayer (SAM) sensing surfaces were pre-adsorbed with one of four different proteins: lysozyme, albumin, transferrin, or IgG. Each surface provides a thermodynamically governed platform for immobilizing proteins and generates analyte-specific response patterns. Each surface has its own thermodynamic energy governing pre-adsorbed protein behaviors, so that sample proteins react with the pre-adsorbed ones to different extents depending on their sizes, isoelectric points (pI), and characteristics of the sensing surfaces. Modified surfaces were mounted and monitored in real time using surface plasmon resonance (SPR). Buffer-prepared sample matrices (α1-antitrypsin, haptoglobin, C-reactive protein (CRP), and IgM) characterized protein response patterns. Each surface generated distinctive patterns based on individual SPR angle shifts. We classified each sample with 95% accuracy using linear discriminant analysis (LDA). Our method also discriminated between different concentrations of CRP in the cocktail sample, detecting concentrations as low as 1 nM with 91.7% accuracy. This technique may be integrated with a microfluidic lab-on-a-chip system and monitor the distribution of a specific group of proteins in human serum.
Collapse
Affiliation(s)
- Seokheun Choi
- School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona, USA.
| | | | | | | |
Collapse
|
27
|
Cheng TM, Lee TC, Tseng SH, Chu HL, Pan JP, Chang CC. Human haptoglobin phenotypes and concentration determination by nanogold-enhanced electrochemical impedance spectroscopy. NANOTECHNOLOGY 2011; 22:245105. [PMID: 21543834 DOI: 10.1088/0957-4484/22/24/245105] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Haptoglobin (Hp) is an acute phase protein that binds free hemoglobin (Hb), preventing Hb-induced oxidative damage in the vascular system. There are three phenotypes in human Hp, whose heterogeneous polymorphic structures and varying concentrations in plasma have been attributed to the cause of diseases and outcome of clinical treatments. Different phenotypes of Hp may be composed of the same subunits but different copy numbers, rendering their determination difficult by a single procedure. In this study, we have developed a simple, fast, reliable and sensitive method, using label-free nanogold-modified bioprobes coupled with self-development electrochemical impedance spectroscopy (EIS). By this method, probe surface charge transfer resistance is detected. The relative charge transfer resistance ratios for Hp 1-1, Hp 2-1 and Hp 2-2 were characterized. We were able to determine protein size difference within 3 nm, and the linear region of the calibration curve for Hp levels in the range of 90 pg ml(-1) and 90 µg ml(-1) (∼1 fM to 1 pM). We surmise that similar approaches can be used to investigate protein polymorphism and altered protein-protein interaction associated with diseases.
Collapse
Affiliation(s)
- Tsai-Mu Cheng
- Department of Biological Science and Technology, National Chiao Tung University, Hsinchu, Taiwan, Republic of China
| | | | | | | | | | | |
Collapse
|
28
|
Boltovets P, Shinkaruk S, Bennetau-Pelissero C, Bennetau B, Snopok B. The effect of low pH on the glycitein–BSA conjugate interaction with specific antiserum: Competitive inhibition study using surface plasmon resonance technique. Talanta 2011; 84:867-73. [DOI: 10.1016/j.talanta.2011.02.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2010] [Revised: 02/02/2011] [Accepted: 02/14/2011] [Indexed: 11/26/2022]
|
29
|
Gun'ko VM, Mikhalovska LI, Tomlins PE, Mikhalovsky SV. Competitive adsorption of macromolecules and real-time dynamics of Vroman-like effects. Phys Chem Chem Phys 2011; 13:4476-85. [DOI: 10.1039/c0cp02165b] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
30
|
Choi S, Goryll M, Sin LYM, Wong PK, Chae J. Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins. MICROFLUIDICS AND NANOFLUIDICS 2011; 10:231-247. [PMID: 32214951 PMCID: PMC7087901 DOI: 10.1007/s10404-010-0638-8] [Citation(s) in RCA: 133] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2010] [Accepted: 04/26/2010] [Indexed: 05/14/2023]
Abstract
This article reviews state-of-the-art microfluidic biosensors of nucleic acids and proteins for point-of-care (POC) diagnostics. Microfluidics is capable of analyzing small sample volumes (10-9-10-18 l) and minimizing costly reagent consumption as well as automating sample preparation and reducing processing time. The merger of microfluidics and advanced biosensor technologies offers new promises for POC diagnostics, including high-throughput analysis, portability and disposability. However, this merger also imposes technological challenges on biosensors, such as high sensitivity and selectivity requirements with sample volumes orders of magnitude smaller than those of conventional practices, false response errors due to non-specific adsorption, and integrability with other necessary modules. There have been many prior review articles on microfluidic-based biosensors, and this review focuses on the recent progress in last 5 years. Herein, we review general technologies of DNA and protein biosensors. Then, recent advances on the coupling of the biosensors to microfluidics are highlighted. Finally, we discuss the key challenges and potential solutions for transforming microfluidic biosensors into POC diagnostic applications.
Collapse
Affiliation(s)
- Seokheun Choi
- School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 USA
| | - Michael Goryll
- School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 USA
| | - Lai Yi Mandy Sin
- Department of Aerospace and Mechanical Engineering, University of Arizona, Tucson, AZ 85721 USA
| | - Pak Kin Wong
- Department of Aerospace and Mechanical Engineering, University of Arizona, Tucson, AZ 85721 USA
| | - Junseok Chae
- School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, AZ 85287 USA
| |
Collapse
|
31
|
Oita I, Halewyck H, Thys B, Rombaut B, Vander Heyden Y, Mangelings D. Microfluidics in macro-biomolecules analysis: macro inside in a nano world. Anal Bioanal Chem 2010; 398:239-64. [PMID: 20549494 PMCID: PMC7079953 DOI: 10.1007/s00216-010-3857-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2010] [Revised: 05/13/2010] [Accepted: 05/18/2010] [Indexed: 12/26/2022]
Abstract
Use of microfluidic devices in the life sciences and medicine has created the possibility of performing investigations at the molecular level. Moreover, microfluidic devices are also part of the technological framework that has enabled a new type of scientific information to be revealed, i.e. that based on intensive screening of complete sets of gene and protein sequences. A deeper bioanalytical perspective may provide quantitative and qualitative tools, enabling study of various diseases and, eventually, may offer support for the development of accurate and reliable methods for clinical assessment. This would open the way to molecule-based diagnostics, i.e. establish accurate diagnosis and disease prognosis based on identification and/or quantification of biomacromolecules, for example proteins or nucleic acids. Finally, the development of disposable and portable devices for molecule-based diagnosis would provide the perfect translation of the science behind life-science research into practical applications dedicated to patients and health practitioners. This review provides an analytical perspective of the impact of microfluidics on the detection and characterization of bio-macromolecules involved in pathological processes. The main features of molecule-based diagnostics and the specific requirements for the diagnostic devices are discussed. Further, the techniques currently used for testing bio-macromolecules for potential diagnostic purposes are identified, emphasizing the newest developments. Subsequently, the challenges of this type of application and the status of commercially available devices are highlighted, and future trends are noted.
Collapse
Affiliation(s)
- Iuliana Oita
- Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Hadewych Halewyck
- Department of Pharmaceutical Biotechnology & Molecular Biology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Bert Thys
- Department of Pharmaceutical Biotechnology & Molecular Biology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Bart Rombaut
- Department of Pharmaceutical Biotechnology & Molecular Biology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Yvan Vander Heyden
- Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Debby Mangelings
- Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| |
Collapse
|