1
|
Yu S, Dai W, Su C, Milosavic N, Wang Z, Wang X, Zhu Y, He M, Landry DW, Stojanovic MN, Lin Q. An Internally Attached Aptameric Graphene Nanosensor for Sensitive Vasopressin Measurement in Critical Patient Monitoring. ACS Sens 2024; 9:4915-4923. [PMID: 39268764 DOI: 10.1021/acssensors.4c01519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/15/2024]
Abstract
This paper presents an aptameric graphene nanosensor for rapid and sensitive measurement of arginine vasopressin (AVP) toward continuous monitoring of critical care patients. The nanosensor is a field-effect transistor (FET) with monolayer graphene as the conducting channel and is functionalized with a new custom-designed aptamer for specific AVP recognition. Binding between the aptamer and AVP induces a change in the carrier density in the graphene and resulting in measurable changes in FET characteristics for determination of the AVP concentration. The aptamer, based on the natural enantiomer D-deoxyribose, possess optimized kinetic binding properties and is attached at an internal position to the graphene for enhanced sensitivity to low concentrations of AVP. Experimental results show that this aptameric graphene nanosensor is highly sensitive (with a limit of detection of 0.3 pM and a resolution of 0.1 pM) to AVP, and rapidly responsive (within 90 s) to both increasing and decreasing AVP concentration changes. The device is also reversable (within 4%), repeatable (within 4%) and reproducible (within 5%) in AVP measurements.
Collapse
Affiliation(s)
- Shifeng Yu
- College of Mechanical and Vehicle Engineering, Chongqing University, Chongqing 400044, China
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Wenting Dai
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Chao Su
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
- Department of Power and Energy Engineering, Xian Jiaotong University, Xian, Shaanxi 710049, China
| | - Nenad Milosavic
- Department of Medicine, Columbia University, New York, New York 10032, United States
| | - Ziran Wang
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Xuejun Wang
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Yibo Zhu
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Maogang He
- Department of Power and Energy Engineering, Xian Jiaotong University, Xian, Shaanxi 710049, China
| | - Donald W Landry
- Department of Medicine, Columbia University, New York, New York 10032, United States
| | - Milan N Stojanovic
- Department of Medicine, Columbia University, New York, New York 10032, United States
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| |
Collapse
|
2
|
Wang C, Weng G, Li J, Zhu J, Zhao J. A review of SERS coupled microfluidic platforms: From configurations to applications. Anal Chim Acta 2024; 1296:342291. [PMID: 38401925 DOI: 10.1016/j.aca.2024.342291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Revised: 01/25/2024] [Accepted: 01/26/2024] [Indexed: 02/26/2024]
Abstract
Microfluidic systems have attracted considerable attention due to their low reagent consumption, short analysis time, and ease of integration in comparison to conventional methods, but still suffer from shortcomings in sensitivity and selectivity. Surface enhanced Raman scattering (SERS) offers several advantages in the detection of compounds, including label-free detection at the single-molecule level, and the narrow Raman peak width for multiplexing. Combining microfluidics with SERS is a viable way to improve their detection sensitivity. Researchers have recently developed several SERS coupled microfluidic platforms with substantial potential for biomolecular detection, cellular and bacterial analysis, and hazardous substance detection. We review the current development of SERS coupled microfluidic platforms, illustrate their detection principles and construction, and summarize the latest applications in biology, environmental protection and food safety. In addition, we innovatively summarize the current status of SERS coupled multi-mode microfluidic platforms with other detection technologies. Finally, we discuss the challenges and countermeasures during the development of SERS coupled microfluidic platforms, as well as predict the future development trend of SERS coupled microfluidic platforms.
Collapse
Affiliation(s)
- Chenyang Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an 710049, China
| | - Guojun Weng
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an 710049, China.
| | - Jianjun Li
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an 710049, China
| | - Jian Zhu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an 710049, China
| | - Junwu Zhao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, No. 28 Xianning West Road, Xi'an 710049, China.
| |
Collapse
|
3
|
Ilyas A, Dyussupova A, Sultangaziyev A, Shevchenko Y, Filchakova O, Bukasov R. SERS immuno- and apta-assays in biosensing/bio-detection: Performance comparison, clinical applications, challenges. Talanta 2023; 265:124818. [PMID: 37453393 DOI: 10.1016/j.talanta.2023.124818] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 06/09/2023] [Accepted: 06/12/2023] [Indexed: 07/18/2023]
Abstract
Surface Enhanced Raman Spectroscopy is increasingly used as a sensitive bioanalytical tool for detection of variety of analytes ranging from viruses and bacteria to cancer biomarkers and toxins, etc. This comprehensive review describes principles of operation and compares the performance of immunoassays and aptamer assays with Surface Enhanced Raman scattering (SERS) detection to each other and to some other bioassay methods, including ELISA and fluorescence assays. Both immuno- and aptamer-based assays are categorized into assay on solid substrates, assays with magnetic nanoparticles and assays in laminar flow or/and strip assays. The best performing and recent examples of assays in each category are described in the text and illustrated in the figures. The average performance, particularly, limit of detection (LOD) for each of those methods reflected in 9 tables of the manuscript and average LODs are calculated and compared. We found out that, on average, there is some advantage in terms of LOD for SERS immunoassays (0.5 pM median LOD of 88 papers) vs SERS aptamer-based assays (1.7 pM median LOD of 51 papers). We also tabulated and analyzed the clinical performance of SERS immune and aptamer assays, where selectivity, specificity, and accuracy are reported, we summarized the best examples. We also reviewed challenges to SERS bioassay performance and real-life application, including non-specific protein binding, nanoparticle aggregation, limited nanotag stability, sometimes, relatively long time to results, etc. The proposed solutions to those challenges are also discussed in the review. Overall, this review may be interesting not only to bioanalytical chemist, but to medical and life science researchers who are interested in improvement of bioanalyte detection and diagnostics.
Collapse
Affiliation(s)
- Aisha Ilyas
- Department of Chemistry, SSH, Nazarbayev University, Astana, Kazakhstan
| | | | | | - Yegor Shevchenko
- Department of Chemistry, SSH, Nazarbayev University, Astana, Kazakhstan
| | - Olena Filchakova
- Department of Biology, SSH, Nazarbayev University, Astana, Kazakhstan
| | - Rostislav Bukasov
- Department of Chemistry, SSH, Nazarbayev University, Astana, Kazakhstan.
| |
Collapse
|
4
|
Panneerselvam R, Sadat H, Höhn EM, Das A, Noothalapati H, Belder D. Microfluidics and surface-enhanced Raman spectroscopy, a win-win combination? LAB ON A CHIP 2022; 22:665-682. [PMID: 35107464 DOI: 10.1039/d1lc01097b] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
With the continuous development in nanoscience and nanotechnology, analytical techniques like surface-enhanced Raman spectroscopy (SERS) render structural and chemical information of a variety of analyte molecules in ultra-low concentration. Although this technique is making significant progress in various fields, the reproducibility of SERS measurements and sensitivity towards small molecules are still daunting challenges. In this regard, microfluidic surface-enhanced Raman spectroscopy (MF-SERS) is well on its way to join the toolbox of analytical chemists. This review article explains how MF-SERS is becoming a powerful tool in analytical chemistry. We critically present the developments in SERS substrates for microfluidic devices and how these substrates in microfluidic channels can improve the SERS sensitivity, reproducibility, and detection limit. We then introduce the building materials for microfluidic platforms and their types such as droplet, centrifugal, and digital microfluidics. Finally, we enumerate some challenges and future directions in microfluidic SERS. Overall, this article showcases the potential and versatility of microfluidic SERS in overcoming the inherent issues in the SERS technique and also discusses the advantage of adding SERS to the arsenal of microfluidics.
Collapse
Affiliation(s)
- Rajapandiyan Panneerselvam
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
- Department of Chemistry, SRM University AP, Amaravati, Andhra Pradesh 522502, India.
| | - Hasan Sadat
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Eva-Maria Höhn
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Anish Das
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Hemanth Noothalapati
- Faculty of Life and Environmental Sciences, Shimane University, Matsue, Japan
- Raman Project Center for Medical and Biological Applications, Shimane University, Matsue, Japan
| | - Detlev Belder
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
5
|
Xia L, Li G. Recent progress of microfluidics in surface-enhanced Raman spectroscopic analysis. J Sep Sci 2021; 44:1752-1768. [PMID: 33630352 DOI: 10.1002/jssc.202001196] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 02/20/2021] [Accepted: 02/20/2021] [Indexed: 12/21/2022]
Abstract
Surface-enhanced Raman spectroscopy is a significant analytical tool capable of fingerprint identification of molecule in a rapid and ultrasensitive manner. However, it is still hard to meet the requirements of practical sample analysis. The introduction of microfluidics can effectively enhance the performance of surface-enhanced Raman spectroscopy in complex sample analysis including reproducibility, selectivity, sensitivity, and speed. This review summarizes the recent progress of microfluidics in surface-enhanced Raman spectroscopic analysis through four combination approaches. First, microfluidic synthetic techniques offer uniform nano-/microparticle fabrication approaches for reproductive surface-enhanced Raman spectroscopic analysis. Second, the integration of microchip and surface-enhanced Raman spectroscopic substrate provides advanced devices for sensitive and efficient detection. Third, microfluidic sample preparations enable rapid separation and preconcentration of analyte prior to surface-enhanced Raman spectroscopic detection. Fourth, highly integrated microfluidic devices can be employed to realize multistep surface-enhanced Raman spectroscopic analysis containing material fabrication, sample preparation, and detection processes. Furthermore, the challenges and outlooks of the application of microfluidics in surface-enhanced Raman spectroscopic analysis are discussed.
Collapse
Affiliation(s)
- Ling Xia
- School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| | - Gongke Li
- School of Chemistry, Sun Yat-sen University, Guangzhou, P. R. China
| |
Collapse
|
6
|
Low JSY, Thevarajah TM, Chang SW, Goh BT, Khor SM. Biosensing based on surface-enhanced Raman spectroscopy as an emerging/next-generation point-of-care approach for acute myocardial infarction diagnosis. Crit Rev Biotechnol 2020; 40:1191-1209. [PMID: 32811205 DOI: 10.1080/07388551.2020.1808582] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Cardiovascular disease is a major global health issue. In particular, acute myocardial infarction (AMI) requires urgent attention and early diagnosis. The use of point-of-care diagnostics has resulted in the improved management of cardiovascular disease, but a major drawback is that the performance of POC devices does not rival that of central laboratory tests. Recently, many studies and advances have been made in the field of surface-enhanced Raman scattering (SERS), including the development of POC biosensors that utilize this detection method. Here, we present a review of the strengths and limitations of these emerging SERS-based biosensors for AMI diagnosis. The ability of SERS to multiplex sensing against existing POC detection methods are compared and discussed. Furthermore, SERS calibration-free methods that have recently been explored to minimize the inconvenience and eliminate the limitations caused by the limited linear range and interassay differences found in the calibration curves are outlined. In addition, the incorporation of artificial intelligence (AI) in SERS techniques to promote multivariate analysis and enhance diagnostic accuracy are discussed. The future prospects for SERS-based POC devices that include wearable POC SERS devices toward predictive, personalized medicine following the Fourth Industrial Revolution are proposed.
Collapse
Affiliation(s)
- Joyce Siew Yong Low
- Faculty of Science, Department of Chemistry, University of Malaya, Kuala Lumpur, Malaysia
| | - T Malathi Thevarajah
- Faculty of Medicine, Department of Pathology, University of Malaya, Kuala Lumpur, Malaysia
| | - Siow Wee Chang
- Faculty of Science, Institute of Biological Sciences, University of Malaya, Kuala Lumpur, Malaysia
| | - Boon Tong Goh
- Faculty of Science, Low Dimensional Materials Research Centre, Department of Physics, University of Malaya, Kuala Lumpur, Malaysia
| | - Sook Mei Khor
- Faculty of Science, Department of Chemistry, University of Malaya, Kuala Lumpur, Malaysia.,Faculty of Engineering, Centre for Innovation in Medical Engineering, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
7
|
Hu B, Boakye‐Yiadom KO, Yu W, Yuan Z, Ho W, Xu X, Zhang X. Nanomedicine Approaches for Advanced Diagnosis and Treatment of Atherosclerosis and Related Ischemic Diseases. Adv Healthc Mater 2020; 9:e2000336. [PMID: 32597562 DOI: 10.1002/adhm.202000336] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Revised: 04/30/2020] [Indexed: 12/16/2022]
Abstract
Cardiovascular diseases (CVDs) remain one of the major causes of mortality worldwide. In response to this and other worldwide health epidemics, nanomedicine has emerged as a rapidly evolving discipline that involves the development of innovative nanomaterials and nanotechnologies and their applications in therapy and diagnosis. Nanomedicine presents unique advantages over conventional medicines due to the superior properties intrinsic to nanoscopic therapies. Once used mainly for cancer therapies, recently, tremendous progress has been made in nanomedicine that has led to an overall improvement in the treatment and diagnosis of CVDs. This review elucidates the pathophysiology and potential targets of atherosclerosis and associated ischemic diseases. It may be fruitful to pursue future work in the nanomedicine-mediated treatment of CVDs based on these targets. A comprehensive overview is then provided featuring the latest preclinical and clinical outcomes in cardiovascular imaging, biomarker detection, tissue engineering, and nanoscale delivery, with specific emphasis on nanoparticles, nanostructured scaffolds, and nanosensors. Finally, the challenges and opportunities regarding the future development and clinical translation of nanomedicine in related fields are discussed. Overall, this review aims to provide a deep and thorough understanding of the design, application, and future development of nanomedicine for atherosclerosis and related ischemic diseases.
Collapse
Affiliation(s)
- Bin Hu
- Engineering Research Center of Cell & Therapeutic Antibody, Ministry of Education, and School of PharmacyShanghai Jiao Tong University 800 Dongchuan Road Shanghai 200240 P. R. China
| | - Kofi Oti Boakye‐Yiadom
- Engineering Research Center of Cell & Therapeutic Antibody, Ministry of Education, and School of PharmacyShanghai Jiao Tong University 800 Dongchuan Road Shanghai 200240 P. R. China
| | - Wei Yu
- Engineering Research Center of Cell & Therapeutic Antibody, Ministry of Education, and School of PharmacyShanghai Jiao Tong University 800 Dongchuan Road Shanghai 200240 P. R. China
| | - Zi‐Wei Yuan
- Engineering Research Center of Cell & Therapeutic Antibody, Ministry of Education, and School of PharmacyShanghai Jiao Tong University 800 Dongchuan Road Shanghai 200240 P. R. China
| | - William Ho
- Department of Chemical and Materials EngineeringNew Jersey Institute of Technology Newark NJ 07102 USA
| | - Xiaoyang Xu
- Department of Chemical and Materials EngineeringNew Jersey Institute of Technology Newark NJ 07102 USA
| | - Xue‐Qing Zhang
- Engineering Research Center of Cell & Therapeutic Antibody, Ministry of Education, and School of PharmacyShanghai Jiao Tong University 800 Dongchuan Road Shanghai 200240 P. R. China
| |
Collapse
|
8
|
Ultrasensitive and Highly Selective Graphene-Based Field-Effect Transistor Biosensor for Anti-Diuretic Hormone Detection. SENSORS 2020; 20:s20092642. [PMID: 32384631 PMCID: PMC7248865 DOI: 10.3390/s20092642] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Revised: 04/10/2020] [Accepted: 04/13/2020] [Indexed: 01/06/2023]
Abstract
Nephrogenic diabetes insipidus (NDI), which can be congenital or acquired, results from the failure of the kidney to respond to the anti-diuretic hormone (ADH). This will lead to excessive water loss from the body in the form of urine. The kidney, therefore, has a crucial role in maintaining water balance and it is vital to restore this function in an artificial kidney. Herein, an ultrasensitive and highly selective aptameric graphene-based field-effect transistor (GFET) sensor for ADH detection was developed by directly immobilizing ADH-specific aptamer on a surface-modified suspended graphene channel. This direct immobilization of aptamer on the graphene surface is an attempt to mimic the functionality of collecting tube V 2 receptors in the ADH biosensor. This aptamer was then used as a probe to capture ADH peptide at the sensing area which leads to changes in the concentration of charge carriers in the graphene channel. The biosensor shows a significant increment in the relative change of current ratio from 5.76 to 22.60 with the increase of ADH concentration ranging from 10 ag/mL to 1 pg/mL. The ADH biosensor thus exhibits a sensitivity of 50.00 µA· ( g / mL ) - 1 with a limit of detection as low as 3.55 ag/mL. In specificity analysis, the ADH biosensor demonstrated a higher current value which is 338.64 µA for ADH-spiked in phosphate-buffered saline (PBS) and 557.89 µA for ADH-spiked in human serum in comparison with other biomolecules tested. This experimental evidence shows that the ADH biosensor is ultrasensitive and highly selective towards ADH in PBS buffer and ADH-spiked in human serum.
Collapse
|
9
|
Aptamer-Based Nanoporous Anodic Alumina Interferometric Biosensor for Real-Time Thrombin Detection. SENSORS 2019; 19:s19204543. [PMID: 31635027 PMCID: PMC6833485 DOI: 10.3390/s19204543] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Revised: 10/10/2019] [Accepted: 10/15/2019] [Indexed: 12/18/2022]
Abstract
Aptamer biosensors are one of the most powerful techniques in biosensing. Achieving the best platform to use in aptamer biosensors typically includes crucial chemical modifications that enable aptamer immobilization on the surface in the most efficient manner. These chemical modifications must be well defined. In this work we propose nanoporous anodic alumina (NAA) chemically modified with streptavidin as a platform for aptamer immobilization. The immobilization of biotinylated thrombin binding aptamer (TBA) was monitored in real time by means of reflective interferometric spectroscopy (RIfS). The study has permitted to characterize in real time the path to immobilize TBA on the inner pore walls of NAA. Furthermore, this study provides an accurate label-free method to detect thrombin in real-time with high affinity and specificity.
Collapse
|
10
|
Xing Y, Dittrich PS. One-Dimensional Nanostructures: Microfluidic-Based Synthesis, Alignment and Integration towards Functional Sensing Devices. SENSORS 2018; 18:s18010134. [PMID: 29303990 PMCID: PMC5795670 DOI: 10.3390/s18010134] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Revised: 12/29/2017] [Accepted: 12/31/2017] [Indexed: 12/23/2022]
Abstract
Microfluidic-based synthesis of one-dimensional (1D) nanostructures offers tremendous advantages over bulk approaches e.g., the laminar flow, reduced sample consumption and control of self-assembly of nanostructures. In addition to the synthesis, the integration of 1D nanomaterials into microfluidic chips can enable the development of diverse functional microdevices. 1D nanomaterials have been used in applications such as catalysts, electronic instrumentation and sensors for physical parameters or chemical compounds and biomolecules and hence, can be considered as building blocks. Here, we outline and critically discuss promising strategies for microfluidic-assisted synthesis, alignment and various chemical and biochemical applications of 1D nanostructures. In particular, the use of 1D nanostructures for sensing chemical/biological compounds are reviewed.
Collapse
Affiliation(s)
- Yanlong Xing
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e. V, 12489 Berlin, Germany.
| | - Petra S Dittrich
- Department of Biosystems Science and Engineering, ETH Zürich, 4058 Basel, Switzerland.
| |
Collapse
|
11
|
Lee CW, Tseng FG. Surface enhanced Raman scattering (SERS) based biomicrofluidics systems for trace protein analysis. BIOMICROFLUIDICS 2018; 12:011502. [PMID: 29430272 PMCID: PMC5780278 DOI: 10.1063/1.5012909] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2017] [Accepted: 01/11/2018] [Indexed: 05/03/2023]
Abstract
In recent years, Surface Enhanced Raman Scattering (SERS) has been widely applied to many different areas, including chemical analysis, biomolecule detection, bioagent diagnostics, DNA sequence, and environmental monitor, due to its capabilities of unlabeled fingerprint identification, high sensitivity, and rapid detection. In biomicrofluidic systems, it is also very powerful to integrate SERS based devices with specified micro-fluid flow fields to further focusing/enhancing/multiplexing SERS signals through molecule registration, concentration/accumulation, and allocation. In this review, after a brief introduction of the mechanism of SERS detection on proteins, we will first focus on the effectiveness of different nanostructures for SERS enhancement and light-to-heat conversion in trace protein analysis. Various protein molecule accumulation schemes by either (bio-)chemical or physical ways, such as immuno, electrochemical, Tip-enhanced Raman spectroscopy, and magnetic, will then be reviewed for further SERS signal amplification. The analytical and repeatability/stability issues of SERS detection on proteins will also be brought up for possible solutions. Then, the comparison about various ways employing microfluidic systems to register, concentrate, and enhance the signals of SERS and reduce the background noise by active or passive means to manipulate SERS nanostructures and protein molecules will be elaborated. Finally, we will carry on the discussion on the challenges and opportunities by introducing SERS into biomicrofluidic systems and their potential solutions.
Collapse
Affiliation(s)
- Chun-Wei Lee
- Department of Engineering and System, National Tsing Hua University, No. 101, Sec. 2, Kuang-Fu Rd., Hsinchu 30013, Taiwan
| | | |
Collapse
|
12
|
Lim JM, Heo NS, Oh SY, Ryu MY, Seo JH, Park TJ, Huh YS, Park JP. Selection of affinity peptides for interference-free detection of cholera toxin. Biosens Bioelectron 2018; 99:289-295. [DOI: 10.1016/j.bios.2017.07.075] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2017] [Revised: 07/28/2017] [Accepted: 07/30/2017] [Indexed: 02/01/2023]
|
13
|
Kim JY, Park JH, Kim MI, Lee HH, Kim HL, Jeong KS, Moon SO, Kang PW, Park KW, Lee YH, Chun BW. Identification of female-specific blood stains using a 17β-estradiol-targeted aptamer-based sensor. Int J Legal Med 2017; 132:91-98. [PMID: 29086052 DOI: 10.1007/s00414-017-1718-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Accepted: 10/11/2017] [Indexed: 01/08/2023]
Abstract
Blood stain evidence obtained from a violent crime scene provides decisive clues that can enable a case to be solved through forensic analyses such as genetic identification. However, collected samples usually contain a mixture of biological material from different sources, making genetic identification difficult. To address this issue, we developed an activatable aptamer sensor targeting 17β-estradiol for detection of female-specific blood in mixed samples. With the sensor, we were able to detect blood originating from females using a variable light source (495 nm). The sensor was especially sensitive to blood from young females (10-40 years) but not to blood from older females (≥ 50 years). Genomic DNA was extracted from the female blood specimens identified by this method and used for quantification and short tandem repeat genotyping. We confirmed that there was no fluorescence interference from the aptamer sensor. These results indicate that this novel aptamer sensor can be used to analyze evidentiary blood samples and thereby facilitate subsequent genetic identification.
Collapse
Affiliation(s)
- Joo-Young Kim
- Crime-scene DNA Section, National Forensic Service, Gwangju Institute, Gwangju, 57231, Republic of Korea
| | - Jung-Hyun Park
- Mibyeong Research Center, Korea Institute of Oriental Medicine, Daejeon, 34054, Republic of Korea
| | - Man Il Kim
- Crime-scene DNA Section, National Forensic Service, Gwangju Institute, Gwangju, 57231, Republic of Korea
| | - Hye Hyeon Lee
- Crime-scene DNA Section, National Forensic Service, Gwangju Institute, Gwangju, 57231, Republic of Korea
| | - Hye Lim Kim
- Crime-scene DNA Section, National Forensic Service, Gwangju Institute, Gwangju, 57231, Republic of Korea
| | - Kyu-Sik Jeong
- Forensic DNA Division, National Forensic Service, Wonju, 26460, Republic of Korea
| | - Sang-Ok Moon
- Crime-scene DNA Section, National Forensic Service, Gwangju Institute, Gwangju, 57231, Republic of Korea
| | - Pil-Won Kang
- Crime-scene DNA Section, National Forensic Service, Gwangju Institute, Gwangju, 57231, Republic of Korea
| | - Ki-Won Park
- Forensic DNA Division, National Forensic Service, Wonju, 26460, Republic of Korea
| | - Yang-Han Lee
- Forensic DNA Division, National Forensic Service, Wonju, 26460, Republic of Korea
| | - Byung-Won Chun
- Forensic DNA Division, National Forensic Service, Wonju, 26460, Republic of Korea.
| |
Collapse
|
14
|
Yang J, Zhu J, Pei R, Oliver JA, Landry DW, Stojanovic MN, Lin Q. Integrated Microfluidic Aptasensor for Mass Spectrometric Detection of Vasopressin in Human Plasma Ultrafiltrate. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2016; 8:5190-5196. [PMID: 28090219 PMCID: PMC5228624 DOI: 10.1039/c5ay02979a] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
We present a microfluidic aptamer-based biosensor for detection of low-molecular-weight biomarkers in patient samples. Using a microfluidic device that integrates aptamer-based specific analyte extraction, isocratic elution, and detection by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry, we demonstrate rapid, sensitive and label-free detection of arginine vasopressin (AVP) in human plasma ultrafiltrate. AVP molecules in complex matrices are specifically captured by an aptamer that is immobilized on microbeads via affinity binding in a microchamber. After the removal of unbound, contaminating molecules through washing, aptamer-AVP complexes are thermally disrupted via on-chip temperature control. Released AVP molecules are eluted with purified water and transferred to a separate microchamber, and deposited onto a single spot on a MALDI plate via repeated, piezoelectrically actuated ejection, which enriches AVP molecules over the spot area. This integrated on-chip sample processing enables the quantitative detection of low-abundance AVP by MALDI-TOF mass spectrometry in a rapid and label-free manner. Our experimental results show the detection of AVP in human plasma ultrafiltrate as low as physiologically relevant picomolar concentrations via aptamer-based selective preconcentration, demonstrating the potential of our approach as a rapid (~ 1hr), sensitive clinical AVP assay.
Collapse
Affiliation(s)
- J. Yang
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, United States
| | - J. Zhu
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, United States
| | - R. Pei
- Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou, China
| | - J. A. Oliver
- Department of Medicine, Columbia University, New York, NY 10032, United States
| | - D. W. Landry
- Department of Medicine, Columbia University, New York, NY 10032, United States
| | - M. N. Stojanovic
- Department of Medicine, Columbia University, New York, NY 10032, United States
| | - Q. Lin
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, United States
| |
Collapse
|
15
|
Xie Y, Yang S, Mao Z, Li P, Zhao C, Cohick Z, Huang PH, Huang TJ. In situ fabrication of 3D Ag@ZnO nanostructures for microfluidic surface-enhanced Raman scattering systems. ACS NANO 2014; 8:12175-84. [PMID: 25402207 PMCID: PMC4278689 DOI: 10.1021/nn503826r] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2014] [Accepted: 11/07/2014] [Indexed: 05/20/2023]
Abstract
In this work, we develop an in situ method to grow highly controllable, sensitive, three-dimensional (3D) surface-enhanced Raman scattering (SERS) substrates via an optothermal effect within microfluidic devices. Implementing this approach, we fabricate SERS substrates composed of Ag@ZnO structures at prescribed locations inside microfluidic channels, sites within which current fabrication of SERS structures has been arduous. Conveniently, properties of the 3D Ag@ZnO nanostructures such as length, packing density, and coverage can also be adjusted by tuning laser irradiation parameters. After exploring the fabrication of the 3D nanostructures, we demonstrate a SERS enhancement factor of up to ∼2×10(6) and investigate the optical properties of the 3D Ag@ZnO structures through finite-difference time-domain simulations. To illustrate the potential value of our technique, low concentrations of biomolecules in the liquid state are detected. Moreover, an integrated cell-trapping function of the 3D Ag@ZnO structures records the surface chemical fingerprint of a living cell. Overall, our optothermal-effect-based fabrication technique offers an effective combination of microfluidics with SERS, resolving problems associated with the fabrication of SERS substrates in microfluidic channels. With its advantages in functionality, simplicity, and sensitivity, the microfluidic-SERS platform presented should be valuable in many biological, biochemical, and biomedical applications.
Collapse
Affiliation(s)
- Yuliang Xie
- Department of Engineering Science and Mechanics and Department of Chemical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Shikuan Yang
- Department of Engineering Science and Mechanics and Department of Chemical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Zhangming Mao
- Department of Engineering Science and Mechanics and Department of Chemical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Peng Li
- Department of Engineering Science and Mechanics and Department of Chemical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Chenglong Zhao
- Department of Engineering Science and Mechanics and Department of Chemical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Zane Cohick
- Department of Engineering Science and Mechanics and Department of Chemical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Po-Hsun Huang
- Department of Engineering Science and Mechanics and Department of Chemical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Tony Jun Huang
- Department of Engineering Science and Mechanics and Department of Chemical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| |
Collapse
|
16
|
Luo SC, Sivashanmugan K, Liao JD, Yao CK, Peng HC. Nanofabricated SERS-active substrates for single-molecule to virus detection in vitro: A review. Biosens Bioelectron 2014; 61:232-40. [DOI: 10.1016/j.bios.2014.05.013] [Citation(s) in RCA: 189] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2014] [Revised: 05/02/2014] [Accepted: 05/05/2014] [Indexed: 10/25/2022]
|
17
|
Yang M, Lee KG, Kim JW, Lee SJ, Huh YS, Choi BG. Highly ordered gold-nanotube films for flow-injection amperometric glucose biosensors. RSC Adv 2014. [DOI: 10.1039/c4ra05273k] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
18
|
Yang J, Palla M, Bosco FG, Rindzevicius T, Alstrøm TS, Schmidt MS, Boisen A, Ju J, Lin Q. Surface-enhanced Raman spectroscopy based quantitative bioassay on aptamer-functionalized nanopillars using large-area Raman mapping. ACS NANO 2013; 7:5350-9. [PMID: 23713574 PMCID: PMC3915935 DOI: 10.1021/nn401199k] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Surface-enhanced Raman spectroscopy (SERS) has been used in a variety of biological applications due to its high sensitivity and specificity. Here, we report a SERS-based biosensing approach for quantitative detection of biomolecules. A SERS substrate bearing gold-decorated silicon nanopillars is functionalized with aptamers for sensitive and specific detection of target molecules. In this study, TAMRA-labeled vasopressin molecules in the picomolar regime (1 pM to 1 nM) are specifically captured by aptamers on the nanostructured SERS substrate and monitored by using an automated SERS signal mapping technique. From the experimental results, we show concentration-dependent SERS responses in the picomolar range by integrating SERS signal intensities over a scanning area. It is also noted that our signal mapping approach significantly improves statistical reproducibility and accounts for spot-to-spot variation in conventional SERS quantification. Furthermore, we have developed an analytical model capable of predicting experimental intensity distributions on the substrates for reliable quantification of biomolecules. Lastly, we have calculated the minimum needed area of Raman mapping for efficient and reliable analysis of each measurement. Combining our SERS mapping analysis with an aptamer-functionalized nanopillar substrate is found to be extremely efficient for detection of low-abundance biomolecules.
Collapse
Affiliation(s)
- Jaeyoung Yang
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Mirko Palla
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
- Department of Chemical Engineering, Columbia University, New York, New York 10027, United States
| | - Filippo Giacomo Bosco
- Department of Micro & Nanotechnology, Technical University of Denmark, Lyngby 2800, Denmark
| | - Tomas Rindzevicius
- Department of Micro & Nanotechnology, Technical University of Denmark, Lyngby 2800, Denmark
| | - Tommy Sonne Alstrøm
- Department of Applied Mathematics and Computer Science, Technical University of Denmark, Lyngby 2800, Denmark
| | | | - Anja Boisen
- Department of Micro & Nanotechnology, Technical University of Denmark, Lyngby 2800, Denmark
| | - Jingyue Ju
- Department of Chemical Engineering, Columbia University, New York, New York 10027, United States
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
- Address correspondence to:
| |
Collapse
|
19
|
Galarreta BC, Tabatabaei M, Guieu V, Peyrin E, Lagugné-Labarthet F. Microfluidic channel with embedded SERS 2D platform for the aptamer detection of ochratoxin A. Anal Bioanal Chem 2012. [PMID: 23187825 DOI: 10.1007/s00216-012-6557-7] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
A selective aptameric sequence is adsorbed on a two-dimensional nanostructured metallic platform optimized for surface-enhanced Raman spectroscopy (SERS) measurements. Using nanofabrication methods, a metallic nanostructure was prepared by electron-beam lithography onto a glass coverslip surface and embedded within a microfluidic channel made of polydimethylsiloxane, allowing one to monitor in situ SERS fingerprint spectra from the adsorbed molecules on the metallic nanostructures. The gold structure was designed so that its localized surface plasmon resonance matches the excitation wavelength used for the Raman measurement. This optofluidic device is then used to detect the presence of a toxin, namely ochratoxin-A (OTA), in a confined environment, using very small amounts of chemicals, and short data acquisition times, by taking advantage of the optical properties of a SERS platform to magnify the Raman signals of the aptameric monolayer system and avoiding chemical labeling of the aptamer or the OTA target.
Collapse
Affiliation(s)
- Betty C Galarreta
- Department of Chemistry, University of Western Ontario, London, ON, Canada
| | | | | | | | | |
Collapse
|
20
|
He P, Oncescu V, Lee S, Choi I, Erickson D. Label-free electrochemical monitoring of vasopressin in aptamer-based microfluidic biosensors. Anal Chim Acta 2012; 759:74-80. [PMID: 23260679 DOI: 10.1016/j.aca.2012.10.038] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2012] [Revised: 10/17/2012] [Accepted: 10/20/2012] [Indexed: 11/24/2022]
Abstract
Vasopressin is an indicating biomarker for blood pressure in the human body and low vasopressin levels can be indicative of late-phase hemorrhagic shock or other traumatic injuries. In this paper we have developed an aptamer-based label-free microfluidic biosensor for the electrochemical detection of vasopressin. The detection area consists of aptamers immobilized on carbon nanotubes which specifically capture the vasopressin molecules in solution resulting in changes in conductivity across the sensor. We report a limit of detection of 43 pM in standard solutions and demonstrate high detection specificity toward vasopressin when different interferents are present. The miniaturized microfluidic biosensor offers continuous monitoring of different vasopressin levels with good potential for portability. Ultimately such a system could serve as a point-of-care diagnostics tool for patients with excessive bleeding when standard medical infrastructure is not available.
Collapse
Affiliation(s)
- Peng He
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY 14853, United States
| | | | | | | | | |
Collapse
|
21
|
Pahlow S, März A, Seise B, Hartmann K, Freitag I, Kämmer E, Böhme R, Deckert V, Weber K, Cialla D, Popp J. Bioanalytical application of surface- and tip-enhanced Raman spectroscopy. Eng Life Sci 2012. [DOI: 10.1002/elsc.201100056] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Affiliation(s)
| | | | | | | | | | | | - René Böhme
- Institute of Physical Chemistry and Abbe Center of Photonics; Friedrich-Schiller-University Jena; Germany
| | | | | | | | | |
Collapse
|
22
|
Wen G, Zhou L, Li T, Liang A, Jiang Z. A Sensitive Surface-enhanced Raman Scattering Method for Determination of Melamine with Aptamer-modified Nanosilver Probe. CHINESE J CHEM 2012. [DOI: 10.1002/cjoc.201100182] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
23
|
Ren J, Wang J, Wang J, Luedtke NW, Wang E. Enantioselective and label-free detection of oligopeptide via fluorescent indicator displacement. Biosens Bioelectron 2012; 35:401-406. [PMID: 22483357 DOI: 10.1016/j.bios.2012.03.028] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2011] [Revised: 03/06/2012] [Accepted: 03/15/2012] [Indexed: 02/04/2023]
Abstract
In this work, a simple and label-free fluorescent method via fluorescent indicator displacement (FID) was proposed for enantioselectively determining d-enantiomer of arginine vasopressin (DV) using DV-specific DNA aptamer (V-apt) and one guanidiniophthalocyanine dye (Zn-DIGP). Zn-DIGP that preferentially binds to single-stranded DNA with fluorescence enhancement rather than duplexes occupies the long internal loop of V-apt and generates intensive fluorescence. Then DV is introduced into the solution containing Zn-DIGP and V-apt, and displaces the Zn-DIGP from the binding site of internal loop, leading to fluorescence decrease. But l-enantiomer cannot induce any fluorescence change due to the selectivity of V-apt. This established FID technique can detect DV with a detection limit of 100 nM and exhibits a broad linear range, and is able to discriminate enantiomers of arginine vasopressin unambiguously. Moreover chiral separation by chromatography, complicated experimental procedures and covalent modification of tags (such as organic dyes, redox-active metal complexes) are avoided in our strategy. This simple and label-free method is promising for fabricating diverse aptasensors to determine other biomolecules and drugs.
Collapse
Affiliation(s)
- Jiangtao Ren
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China; Graduate School of the Chinese Academy of Sciences, Beijing 100039, China
| | - Jiahai Wang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China.
| | - Jin Wang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China; Department of Chemistry, Physics and Applied Mathematics, State University of New York at Stony Brook, Stony Brook, NY 11794, USA.
| | - Nathan W Luedtke
- Institute of Organic Chemistry, University of Zürich, Winterthurerstrasse 190, Zürich CH-8057, Switzerland, United Kingdom
| | - Erkang Wang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, China.
| |
Collapse
|
24
|
Citartan M, Gopinath SCB, Tominaga J, Tan SC, Tang TH. Assays for aptamer-based platforms. Biosens Bioelectron 2012; 34:1-11. [PMID: 22326894 DOI: 10.1016/j.bios.2012.01.002] [Citation(s) in RCA: 132] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2011] [Revised: 12/14/2011] [Accepted: 01/06/2012] [Indexed: 11/19/2022]
Abstract
Aptamers are single stranded DNA or RNA oligonucleotides that have high affinity and specificity towards a wide range of target molecules. Aptamers have low molecular weight, amenable to chemical modifications and exhibit stability undeterred by repetitive denaturation and renaturation. Owing to these indispensable advantages, aptamers have been implemented as molecular recognition element as alternative to antibodies in various assays for diagnostics. By amalgamating with a number of methods that can provide information on the aptamer-target complex formation, aptamers have become the elemental tool for numerous biosensor developments. In this review, administration of aptamers in applications involving assays of fluorescence, electrochemistry, nano-label and nano-constructs are discussed. Although detection strategies are different for various aptamer-based assays, the core of the design strategies is similar towards reporting the presence of specific target binding to the corresponding aptamers. It is prognosticated that aptamers will find even broader applications with the development of new methods of transducing aptamer target binding.
Collapse
Affiliation(s)
- Marimuthu Citartan
- Infectious Disease Cluster, Advanced Medical & Dental Institute (AMDI), Universiti Sains Malaysia, 13200 Kepala Batas, Penang, Malaysia
| | | | | | | | | |
Collapse
|
25
|
Lu CH, Wang F, Willner I. Amplified optical aptasensors through the endonuclease-stimulated regeneration of the analyte. Chem Sci 2012. [DOI: 10.1039/c2sc20426f] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
|
26
|
Cialla D, März A, Böhme R, Theil F, Weber K, Schmitt M, Popp J. Surface-enhanced Raman spectroscopy (SERS): progress and trends. Anal Bioanal Chem 2011; 403:27-54. [PMID: 22205182 DOI: 10.1007/s00216-011-5631-x] [Citation(s) in RCA: 413] [Impact Index Per Article: 29.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2011] [Revised: 11/10/2011] [Accepted: 12/01/2011] [Indexed: 12/12/2022]
Abstract
Surface-enhanced Raman spectroscopy (SERS) combines molecular fingerprint specificity with potential single-molecule sensitivity. Therefore, the SERS technique is an attractive tool for sensing molecules in trace amounts within the field of chemical and biochemical analytics. Since SERS is an ongoing topic, which can be illustrated by the increased annual number of publications within the last few years, this review reflects the progress and trends in SERS research in approximately the last three years. The main reason why the SERS technique has not been established as a routine analytic technique, despite its high specificity and sensitivity, is due to the low reproducibility of the SERS signal. Thus, this review is dominated by the discussion of the various concepts for generating powerful, reproducible, SERS-active surfaces. Furthermore, the limit of sensitivity in SERS is introduced in the context of single-molecule spectroscopy and the calculation of the 'real' enhancement factor. In order to shed more light onto the underlying molecular processes of SERS, the theoretical description of SERS spectra is also a growing research field and will be summarized here. In addition, the recording of SERS spectra is affected by a number of parameters, such as laser power, integration time, and analyte concentration. To benefit from synergies, SERS is combined with other methods, such as scanning probe microscopy and microfluidics, which illustrates the broad applications of this powerful technique.
Collapse
Affiliation(s)
- Dana Cialla
- Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University Jena, Jena, Germany
| | | | | | | | | | | | | |
Collapse
|
27
|
Strehlitz B, Reinemann C, Linkorn S, Stoltenburg R. Aptamers for pharmaceuticals and their application in environmental analytics. ACTA ACUST UNITED AC 2011; 4:1-30. [PMID: 22389661 PMCID: PMC3281204 DOI: 10.1007/s12566-011-0026-1] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2011] [Accepted: 11/10/2011] [Indexed: 01/07/2023]
Abstract
Aptamers are single-stranded DNA or RNA oligonucleotides, which are able to bind with high affinity and specificity to their target. This property is used for a multitude of applications, for instance as molecular recognition elements in biosensors and other assays. Biosensor application of aptamers offers the possibility for fast and easy detection of environmental relevant substances. Pharmaceutical residues, deriving from human or animal medical treatment, are found in surface, ground, and drinking water. At least the whole range of frequently administered drugs can be detected in noticeable concentrations. Biosensors and assays based on aptamers as specific recognition elements are very convenient for this application because aptamer development is possible for toxic targets. Commonly used biological receptors for biosensors like enzymes or antibodies are mostly unavailable for the detection of pharmaceuticals. This review describes the research activities of aptamer and sensor developments for pharmaceutical detection, with focus on environmental applications.
Collapse
Affiliation(s)
- Beate Strehlitz
- UFZ-Helmholtz Centre for Environmental Research, Permoserstr. 15, 04318 Leipzig, Germany
| | | | | | | |
Collapse
|
28
|
Sriram S, Bhaskaran M, Chen S, Jayawardhana S, Stoddart PR, Liu JZ, Medhekar NV, Kalantar-Zadeh K, Mitchell A. Influence of Electric Field on SERS: Frequency Effects, Intensity Changes, and Susceptible Bonds. J Am Chem Soc 2011; 134:4646-53. [DOI: 10.1021/ja208893q] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Sharath Sriram
- Microplatforms Research Group, School of Electrical and Computer Engineering, RMIT University, Melbourne, Australia
| | - Madhu Bhaskaran
- Microplatforms Research Group, School of Electrical and Computer Engineering, RMIT University, Melbourne, Australia
| | | | - Sasani Jayawardhana
- Faculty of Engineering and Industrial Science, Swinburne University of Technology, Hawthorn, Australia
| | - Paul R. Stoddart
- Faculty of Engineering and Industrial Science, Swinburne University of Technology, Hawthorn, Australia
| | | | | | - Kourosh Kalantar-Zadeh
- Microplatforms Research Group, School of Electrical and Computer Engineering, RMIT University, Melbourne, Australia
| | - Arnan Mitchell
- Microplatforms Research Group, School of Electrical and Computer Engineering, RMIT University, Melbourne, Australia
| |
Collapse
|
29
|
Qin H, Liu J, Chen C, Wang J, Wang E. An electrochemical aptasensor for chiral peptide detection using layer-by-layer assembly of polyelectrolyte-methylene blue/polyelectrolyte-graphene multilayer. Anal Chim Acta 2011; 712:127-31. [PMID: 22177075 DOI: 10.1016/j.aca.2011.10.044] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2011] [Revised: 10/14/2011] [Accepted: 10/19/2011] [Indexed: 10/15/2022]
Abstract
Here we demonstrate for the first time that by physically adsorbing aptamer onto conductive film assembled via alternate adsorption of graphene/polyelectrolyte and methylene blue/polyelectrolyte, a label-free electrochemical aptasensor with high sensitivity and selectivity for peptide detection is constructed. Graphene multilayer derived from layer-by-layer assembly has played significant roles in this sensing strategy: allowing accumulation of methylene blue, facilitating electron transfer and providing much more adsorption site. As compared to previous electrochemical aptasensors, the current sensor based on graphene multilayer alternated with electroactive molecule layer offers extremely high capability for sensitive detection of target without interference of environmental surrounding. This electroactive probe-confined graphene multilayer confers great flexibility to combine with differential pulse voltammetry (DPV) together. In the presence of target d entiomer of arginine vasopressin (D-VP), the binding of peptide to aptamer block the electron transfer process of MB, leading to decreased current peak of DPV. By this way, this electrochemical aptasensor based on electroactive molecule-intercalated graphene multilayer provide highly sensitive and specific detection of D-VP with the lowest detectable concentration of 1 ng mL(-1) and a wide detection range from 1 to 265 ng mL(-1).
Collapse
Affiliation(s)
- Haixia Qin
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, China
| | | | | | | | | |
Collapse
|
30
|
Du Y, Guo S, Qin H, Dong S, Wang E. Target-induced conjunction of split aptamer as new chiral selector for oligopeptide on graphene-mesoporous silica-gold nanoparticle hybrids modified sensing platform. Chem Commun (Camb) 2011; 48:799-801. [PMID: 22048236 DOI: 10.1039/c1cc15303j] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
A new electrochemical label-free biosensor based on target-induced conjunction of a split aptamer as new chiral selector for oligopeptide using graphene-mesoporous silica-gold NP hybrids (GSGHs) as magnified sensing platform is firstly reported, which showed high sensitivity and selectivity for the detection of D-vasopressin (D-VP).
Collapse
Affiliation(s)
- Yan Du
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, Jilin 130022, PR China
| | | | | | | | | |
Collapse
|
31
|
Chung AJ, Huh YS, Erickson D. Large area flexible SERS active substrates using engineered nanostructures. NANOSCALE 2011; 3:2903-2908. [PMID: 21629884 DOI: 10.1039/c1nr10265f] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Surface enhanced Raman scattering (SERS) is an analytical sensing method that provides label-free detection, molecularly specific information, and extremely high sensitivity. The Raman enhancement that makes this method attractive is mainly attributed to the local amplification of the incident electromagnetic field that occurs when a surface plasmon mode is excited at a metallic nanostructure. Here, we present a simple, cost effective method for creating flexible, large area SERS-active substrates using a new technique we call shadow mask assisted evaporation (SMAE). The advantage of large, flexible SERS substrates such as these is they have more area for multiplexing and can be incorporated into irregular surfaces such as clothing. We demonstrate the formation of four different types of nanostructure arrays (pillar, nib, ellipsoidal cylinder, and triangular tip) by controlling the evaporation angle, substrate rotation, and deposition rate of metals onto anodized alumina nanoporous membranes as large as 27 mm. In addition, we present experimental results showing how a hybrid structure comprising of gold nanospheres embedded in a silver nano-pillar structure can be used to obtain a 50× SERS enhancement over the raw nanoparticles themselves.
Collapse
Affiliation(s)
- Aram J Chung
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY 14853, USA
| | | | | |
Collapse
|
32
|
Chai Y, Tian D, Gu J, Cui H. A novel electrochemiluminescence aptasensor for protein based on a sensitive N-(aminobutyl)-N-ethylisoluminol-functionalized gold nanoprobe. Analyst 2011; 136:3244-51. [PMID: 21655607 DOI: 10.1039/c1an15298j] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel electrochemiluminescence (ECL) aptasensor for platelet-derived growth factor B chain (PDGF-BB) assay was developed by assembling N-(aminobutyl)-N-ethylisoluminol functionalized gold nanoparticles (ABEI-AuNPs) with aptamers as nanoprobes. In the protocol, the biotinylated aptamer capture probes were first immobilized on a streptavidin coated gold nanoparticle (AuNPs) modified electrode, afterwards, the target PDGF-BB and the ABEI-AuNPs tagged aptamer signal probe were successively attached to the modified electrode by virtue of the dimer structure of PDGF-BB to fabricate a "sandwich" conjugate modified electrode, i.e. an aptasensor. ECL measurement was carried out with a double-step potential in carbonate buffer solution containing H(2)O(2). The aptasensor showed high sensitivity and selectivity toward PDGF-BB and specificity toward PDGF-BB aptamer. The detection limit was as low as 2.7 × 10(-14) M. In this work, the ABEI-AuNPs synthesized by a simple seed growth method have been successfully used as aptamer labels, which greatly amplified the ECL signal by binding numbers of ABEI molecules on the surface of AuNPs. The ABEI-AuNPs signal amplification is superior to other reported signal amplification strategies based on aptamer-related polymerase chain reaction or functionalized nanoparticles in simplicity, stability, labeling property and practical applicability. And the ABEI-AuNPs based nanoprobe is more sensitive than the luminol functionalized AuNPs based nanoprobe. Moreover, such an ultra-sensitive and low-cost assay can be accomplished with a simple and fast procedure by using a simple ECL instrumentation. The aptasensor was also applied for the detection of PDGF-BB in human serum samples, showing great application potential. Given these advantages, the ECL aptasensor is well suited for the direct, sensitive and rapid detection of protein in complex clinical samples.
Collapse
Affiliation(s)
- Ying Chai
- CAS Key Laboratory of Soft Matter Chemistry, Department of Chemistry, University of Science & Technology of China, Hefei, Anhui 230026, People's Republic of China
| | | | | | | |
Collapse
|
33
|
Bellan LM, Wu D, Langer RS. Current trends in nanobiosensor technology. WILEY INTERDISCIPLINARY REVIEWS. NANOMEDICINE AND NANOBIOTECHNOLOGY 2011; 3:229-46. [PMID: 21391305 PMCID: PMC4126610 DOI: 10.1002/wnan.136] [Citation(s) in RCA: 98] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The development of tools and processes used to fabricate, measure, and image nanoscale objects has lead to a wide range of work devoted to producing sensors that interact with extremely small numbers (or an extremely small concentration) of analyte molecules. These advances are particularly exciting in the context of biosensing, where the demands for low concentration detection and high specificity are great. Nanoscale biosensors, or nanobiosensors, provide researchers with an unprecedented level of sensitivity, often to the single molecule level. The use of biomolecule-functionalized surfaces can dramatically boost the specificity of the detection system, but can also yield reproducibility problems and increased complexity. Several nanobiosensor architectures based on mechanical devices, optical resonators, functionalized nanoparticles, nanowires, nanotubes, and nanofibers have been demonstrated in the lab. As nanobiosensor technology becomes more refined and reliable, it is likely it will eventually make its way from the lab to the clinic, where future lab-on-a-chip devices incorporating an array of nanobiosensors could be used for rapid screening of a wide variety of analytes at low cost using small samples of patient material.
Collapse
Affiliation(s)
- Leon M Bellan
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
| | | | | |
Collapse
|
34
|
Bellan LM, Wu D, Langer RS. Current trends in nanobiosensor technology. WILEY INTERDISCIPLINARY REVIEWS. NANOMEDICINE AND NANOBIOTECHNOLOGY 2011. [PMID: 21391305 DOI: 10.1002/wnan.v3.310.1002/wnan.136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 04/14/2023]
Abstract
The development of tools and processes used to fabricate, measure, and image nanoscale objects has lead to a wide range of work devoted to producing sensors that interact with extremely small numbers (or an extremely small concentration) of analyte molecules. These advances are particularly exciting in the context of biosensing, where the demands for low concentration detection and high specificity are great. Nanoscale biosensors, or nanobiosensors, provide researchers with an unprecedented level of sensitivity, often to the single molecule level. The use of biomolecule-functionalized surfaces can dramatically boost the specificity of the detection system, but can also yield reproducibility problems and increased complexity. Several nanobiosensor architectures based on mechanical devices, optical resonators, functionalized nanoparticles, nanowires, nanotubes, and nanofibers have been demonstrated in the lab. As nanobiosensor technology becomes more refined and reliable, it is likely it will eventually make its way from the lab to the clinic, where future lab-on-a-chip devices incorporating an array of nanobiosensors could be used for rapid screening of a wide variety of analytes at low cost using small samples of patient material.
Collapse
Affiliation(s)
- Leon M Bellan
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA, USA.
| | | | | |
Collapse
|
35
|
Sun Y, Xu F, Zhang Y, Shi Y, Wen Z, Li Z. Metallic nanostructures assembled by DNA and related applications in surface-enhancement Raman scattering (SERS) detection. ACTA ACUST UNITED AC 2011. [DOI: 10.1039/c1jm11640a] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|