1
|
Hasan J, Bok S. Plasmonic Fluorescence Sensors in Diagnosis of Infectious Diseases. BIOSENSORS 2024; 14:130. [PMID: 38534237 DOI: 10.3390/bios14030130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 02/25/2024] [Accepted: 02/26/2024] [Indexed: 03/28/2024]
Abstract
The increasing demand for rapid, cost-effective, and reliable diagnostic tools in personalized and point-of-care medicine is driving scientists to enhance existing technology platforms and develop new methods for detecting and measuring clinically significant biomarkers. Humanity is confronted with growing risks from emerging and recurring infectious diseases, including the influenza virus, dengue virus (DENV), human immunodeficiency virus (HIV), Ebola virus, tuberculosis, cholera, and, most notably, SARS coronavirus-2 (SARS-CoV-2; COVID-19), among others. Timely diagnosis of infections and effective disease control have always been of paramount importance. Plasmonic-based biosensing holds the potential to address the threat posed by infectious diseases by enabling prompt disease monitoring. In recent years, numerous plasmonic platforms have risen to the challenge of offering on-site strategies to complement traditional diagnostic methods like polymerase chain reaction (PCR) and enzyme-linked immunosorbent assays (ELISA). Disease detection can be accomplished through the utilization of diverse plasmonic phenomena, such as propagating surface plasmon resonance (SPR), localized SPR (LSPR), surface-enhanced Raman scattering (SERS), surface-enhanced fluorescence (SEF), surface-enhanced infrared absorption spectroscopy, and plasmonic fluorescence sensors. This review focuses on diagnostic methods employing plasmonic fluorescence sensors, highlighting their pivotal role in swift disease detection with remarkable sensitivity. It underscores the necessity for continued research to expand the scope and capabilities of plasmonic fluorescence sensors in the field of diagnostics.
Collapse
Affiliation(s)
- Juiena Hasan
- Department of Electrical and Computer Engineering, Ritchie School of Engineering and Computer Science, University of Denver, Denver, CO 80208, USA
| | - Sangho Bok
- Department of Electrical and Computer Engineering, Ritchie School of Engineering and Computer Science, University of Denver, Denver, CO 80208, USA
| |
Collapse
|
2
|
John P, Vasa NJ, Zam A. Optical Biosensors for the Diagnosis of COVID-19 and Other Viruses-A Review. Diagnostics (Basel) 2023; 13:2418. [PMID: 37510162 PMCID: PMC10378272 DOI: 10.3390/diagnostics13142418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 07/12/2023] [Accepted: 07/18/2023] [Indexed: 07/30/2023] Open
Abstract
The sudden outbreak of the COVID-19 pandemic led to a huge concern globally because of the astounding increase in mortality rates worldwide. The medical imaging computed tomography technique, whole-genome sequencing, and electron microscopy are the methods generally used for the screening and identification of the SARS-CoV-2 virus. The main aim of this review is to emphasize the capabilities of various optical techniques to facilitate not only the timely and effective diagnosis of the virus but also to apply its potential toward therapy in the field of virology. This review paper categorizes the potential optical biosensors into the three main categories, spectroscopic-, nanomaterial-, and interferometry-based approaches, used for detecting various types of viruses, including SARS-CoV-2. Various classifications of spectroscopic techniques such as Raman spectroscopy, near-infrared spectroscopy, and fluorescence spectroscopy are discussed in the first part. The second aspect highlights advances related to nanomaterial-based optical biosensors, while the third part describes various optical interferometric biosensors used for the detection of viruses. The tremendous progress made by lab-on-a-chip technology in conjunction with smartphones for improving the point-of-care and portability features of the optical biosensors is also discussed. Finally, the review discusses the emergence of artificial intelligence and its applications in the field of bio-photonics and medical imaging for the diagnosis of COVID-19. The review concludes by providing insights into the future perspectives of optical techniques in the effective diagnosis of viruses.
Collapse
Affiliation(s)
- Pauline John
- Division of Engineering, New York University Abu Dhabi (NYUAD), Abu Dhabi 129188, United Arab Emirates
| | - Nilesh J Vasa
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai 600036, India
| | - Azhar Zam
- Division of Engineering, New York University Abu Dhabi (NYUAD), Abu Dhabi 129188, United Arab Emirates
- Tandon School of Engineering, New York University, Brooklyn, NY 11201, USA
| |
Collapse
|
3
|
Patel SK, Surve J, Parmar J, Ahmed K, Bui FM, Al-Zahrani FA. Recent Advances in Biosensors for Detection of COVID-19 and Other Viruses. IEEE Rev Biomed Eng 2023; 16:22-37. [PMID: 36197867 PMCID: PMC10009816 DOI: 10.1109/rbme.2022.3212038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 06/28/2022] [Accepted: 09/23/2022] [Indexed: 11/06/2022]
Abstract
This century has introduced very deadly, dangerous, and infectious diseases to humankind such as the influenza virus, Ebola virus, Zika virus, and the most infectious SARS-CoV-2 commonly known as COVID-19 and have caused epidemics and pandemics across the globe. For some of these diseases, proper medications, and vaccinations are missing and the early detection of these viruses will be critical to saving the patients. And even the vaccines are available for COVID-19, the new variants of COVID-19 such as Delta, and Omicron are spreading at large. The available virus detection techniques take a long time, are costly, and complex and some of them generates false negative or false positive that might cost patients their lives. The biosensor technique is one of the best qualified to address this difficult challenge. In this systematic review, we have summarized recent advancements in biosensor-based detection of these pandemic viruses including COVID-19. Biosensors are emerging as efficient and economical analytical diagnostic instruments for early-stage illness detection. They are highly suitable for applications related to healthcare, wearable electronics, safety, environment, military, and agriculture. We strongly believe that these insights will aid in the study and development of a new generation of adaptable virus biosensors for fellow researchers.
Collapse
Affiliation(s)
- Shobhit K. Patel
- Department of Computer EngineeringMarwadi UniversityRajkot360003India
| | - Jaymit Surve
- Department of Electrical EngineeringMarwadi UniversityRajkot360003India
| | - Juveriya Parmar
- Department of Mechanical and Materials EngineeringUniversity of Nebraska - LincolnNebraska68588USA
- Department of Electronics and Communication EngineeringMarwadi UniversityRajkot360003India
| | - Kawsar Ahmed
- Department of Electrical and Computer EngineeringUniversity of SaskatchewanSaskatoonSKS79 5A9Canada
- Group of Bio-PhotomatiX, Department of Information and Communication TechnologyMawlana Bhashani Science and Technology UniversitySantoshTangail1902Bangladesh
| | - Francis M. Bui
- Department of Electrical and Computer EngineeringUniversity of SaskatchewanSaskatoonSKS79 5A9Canada
| | | |
Collapse
|
4
|
Abstract
Point-of-care and in-vivo bio-diagnostic tools are the current need for the present critical scenarios in the healthcare industry. The past few decades have seen a surge in research activities related to solving the challenges associated with precise on-site bio-sensing. Cutting-edge fiber optic technology enables the interaction of light with functionalized fiber surfaces at remote locations to develop a novel, miniaturized and cost-effective lab on fiber technology for bio-sensing applications. The recent remarkable developments in the field of nanotechnology provide innumerable functionalization methodologies to develop selective bio-recognition elements for label free biosensors. These exceptional methods may be easily integrated with fiber surfaces to provide highly selective light-matter interaction depending on various transduction mechanisms. In the present review, an overview of optical fiber-based biosensors has been provided with focus on physical principles used, along with the functionalization protocols for the detection of various biological analytes to diagnose the disease. The design and performance of these biosensors in terms of operating range, selectivity, response time and limit of detection have been discussed. In the concluding remarks, the challenges associated with these biosensors and the improvement required to develop handheld devices to enable direct target detection have been highlighted.
Collapse
|
5
|
Sibuyi NRS, Moabelo KL, Fadaka AO, Meyer S, Onani MO, Madiehe AM, Meyer M. Multifunctional Gold Nanoparticles for Improved Diagnostic and Therapeutic Applications: A Review. NANOSCALE RESEARCH LETTERS 2021; 16:174. [PMID: 34866165 PMCID: PMC8645298 DOI: 10.1186/s11671-021-03632-w] [Citation(s) in RCA: 62] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 11/21/2021] [Indexed: 05/07/2023]
Abstract
The medical properties of metals have been explored for centuries in traditional medicine for the treatment of infections and diseases and still practiced to date. Platinum-based drugs are the first class of metal-based drugs to be clinically used as anticancer agents following the approval of cisplatin by the United States Food and Drug Administration (FDA) over 40 years ago. Since then, more metals with health benefits have been approved for clinical trials. Interestingly, when these metals are reduced to metallic nanoparticles, they displayed unique and novel properties that were superior to their bulk counterparts. Gold nanoparticles (AuNPs) are among the FDA-approved metallic nanoparticles and have shown great promise in a variety of roles in medicine. They were used as drug delivery, photothermal (PT), contrast, therapeutic, radiosensitizing, and gene transfection agents. Their biomedical applications are reviewed herein, covering their potential use in disease diagnosis and therapy. Some of the AuNP-based systems that are approved for clinical trials are also discussed, as well as the potential health threats of AuNPs and some strategies that can be used to improve their biocompatibility. The reviewed studies offer proof of principle that AuNP-based systems could potentially be used alone or in combination with the conventional systems to improve their efficacy.
Collapse
Affiliation(s)
- Nicole Remaliah Samantha Sibuyi
- Department of Science and Innovation (DSI)/Mintek Nanotechnology Innovation Centre (NIC) Biolabels Node, Department of Biotechnology, University of the Western Cape, Private Bag X17, Bellville, 7535, South Africa
| | - Koena Leah Moabelo
- Department of Science and Innovation (DSI)/Mintek Nanotechnology Innovation Centre (NIC) Biolabels Node, Department of Biotechnology, University of the Western Cape, Private Bag X17, Bellville, 7535, South Africa
- Nanobiotechnology Research Group, Department of Biotechnology, University of the Western Cape, Bellville, South Africa
| | - Adewale Oluwaseun Fadaka
- Department of Science and Innovation (DSI)/Mintek Nanotechnology Innovation Centre (NIC) Biolabels Node, Department of Biotechnology, University of the Western Cape, Private Bag X17, Bellville, 7535, South Africa
| | - Samantha Meyer
- Department of Biomedical Sciences, Faculty of Health and Wellness Sciences, Cape Peninsula University of Technology, Bellville, South Africa
| | - Martin Opiyo Onani
- Organometallics and Nanomaterials, Department of Chemical Sciences, University of the Western Cape, Bellville, South Africa
| | - Abram Madimabe Madiehe
- Department of Science and Innovation (DSI)/Mintek Nanotechnology Innovation Centre (NIC) Biolabels Node, Department of Biotechnology, University of the Western Cape, Private Bag X17, Bellville, 7535, South Africa.
- Nanobiotechnology Research Group, Department of Biotechnology, University of the Western Cape, Bellville, South Africa.
| | - Mervin Meyer
- Department of Science and Innovation (DSI)/Mintek Nanotechnology Innovation Centre (NIC) Biolabels Node, Department of Biotechnology, University of the Western Cape, Private Bag X17, Bellville, 7535, South Africa.
| |
Collapse
|
6
|
Nasrollahi F, Haghniaz R, Hosseini V, Davoodi E, Mahmoodi M, Karamikamkar S, Darabi MA, Zhu Y, Lee J, Diltemiz SE, Montazerian H, Sangabathuni S, Tavafoghi M, Jucaud V, Sun W, Kim H, Ahadian S, Khademhosseini A. Micro and Nanoscale Technologies for Diagnosis of Viral Infections. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2100692. [PMID: 34310048 PMCID: PMC8420309 DOI: 10.1002/smll.202100692] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 03/19/2021] [Indexed: 05/16/2023]
Abstract
Viral infection is one of the leading causes of mortality worldwide. The growth of globalization significantly increases the risk of virus spreading, making it a global threat to future public health. In particular, the ongoing coronavirus disease 2019 (COVID-19) pandemic outbreak emphasizes the importance of devices and methods for rapid, sensitive, and cost-effective diagnosis of viral infections in the early stages by which their quick and global spread can be controlled. Micro and nanoscale technologies have attracted tremendous attention in recent years for a variety of medical and biological applications, especially in developing diagnostic platforms for rapid and accurate detection of viral diseases. This review addresses advances of microneedles, microchip-based integrated platforms, and nano- and microparticles for sampling, sample processing, enrichment, amplification, and detection of viral particles and antigens related to the diagnosis of viral diseases. Additionally, methods for the fabrication of microchip-based devices and commercially used devices are described. Finally, challenges and prospects on the development of micro and nanotechnologies for the early diagnosis of viral diseases are highlighted.
Collapse
Affiliation(s)
- Fatemeh Nasrollahi
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
- Department of BioengineeringUniversity of California‐Los AngelesLos AngelesCA90095USA
| | - Reihaneh Haghniaz
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
- Department of BioengineeringUniversity of California‐Los AngelesLos AngelesCA90095USA
| | - Vahid Hosseini
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
- Department of BioengineeringUniversity of California‐Los AngelesLos AngelesCA90095USA
| | - Elham Davoodi
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
- Department of BioengineeringUniversity of California‐Los AngelesLos AngelesCA90095USA
- Department of Mechanical and Mechatronics EngineeringUniversity of WaterlooWaterlooONN2L 3G1Canada
| | - Mahboobeh Mahmoodi
- Department of BioengineeringUniversity of California‐Los AngelesLos AngelesCA90095USA
- Department of Biomedical EngineeringYazd BranchIslamic Azad UniversityYazd8915813135Iran
| | | | - Mohammad Ali Darabi
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
- Department of BioengineeringUniversity of California‐Los AngelesLos AngelesCA90095USA
| | - Yangzhi Zhu
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
| | - Junmin Lee
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
| | - Sibel Emir Diltemiz
- Department of BioengineeringUniversity of California‐Los AngelesLos AngelesCA90095USA
- Department of ChemistryFaculty of ScienceEskisehir Technical UniversityEskisehir26470Turkey
| | - Hossein Montazerian
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
- Department of BioengineeringUniversity of California‐Los AngelesLos AngelesCA90095USA
| | | | - Maryam Tavafoghi
- Department of BioengineeringUniversity of California‐Los AngelesLos AngelesCA90095USA
| | - Vadim Jucaud
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
| | - Wujin Sun
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
| | - Han‐Jun Kim
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
| | - Samad Ahadian
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
| | - Ali Khademhosseini
- Terasaki Institute for Biomedical Innovation (TIBI)Los AngelesCA90024USA
| |
Collapse
|
7
|
Trends in the Design of Intensity-Based Optical Fiber Biosensors (2010-2020). BIOSENSORS-BASEL 2021; 11:bios11060197. [PMID: 34203715 PMCID: PMC8232210 DOI: 10.3390/bios11060197] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 06/08/2021] [Accepted: 06/09/2021] [Indexed: 12/29/2022]
Abstract
There exists an increasing interest in monitoring low concentrations of biochemical species, as they allow the early-stage detection of illnesses or the monitoring of the environment quality. Thus, both companies and research groups are focused on the development of accurate, fast and highly sensitive biosensors. Optical fiber sensors have been widely employed for these purposes because they provide several advantages for their use in point-of-care and real-time applications. In particular, this review is focused on optical fiber biosensors based on luminescence and absorption. Apart from the key parameters that determine the performance of a sensor (limit of detection, sensibility, cross-sensibility, etc.), other features are analyzed, such as the optical fiber dimensions, the sensing set ups and the fiber functionalization. The aim of this review is to have a comprehensive insight of the different aspects that must be taken into account when working with this kind of sensors.
Collapse
|
8
|
Preparation, Functionalization, Modification, and Applications of Nanostructured Gold: A Critical Review. ENERGIES 2021. [DOI: 10.3390/en14051278] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Gold nanoparticles (Au NPs) play a significant role in science and technology because of their unique size, shape, properties and broad range of potential applications. This review focuses on the various approaches employed for the synthesis, modification and functionalization of nanostructured Au. The potential catalytic applications and their enhancement upon modification of Au nanostructures have also been discussed in detail. The present analysis also offers brief summaries of the major Au nanomaterials synthetic procedures, such as hydrothermal, solvothermal, sol-gel, direct oxidation, chemical vapor deposition, sonochemical deposition, electrochemical deposition, microwave and laser pyrolysis. Among the various strategies used for improving the catalytic performance of nanostructured Au, the modification and functionalization of nanostructured Au produced better results. Therefore, various synthesis, modification and functionalization methods employed for better catalytic outcomes of nanostructured Au have been summarized in this review.
Collapse
|
9
|
Park JA, Kim J, Kim SM, Sohn H, Park C, Kim TH, Lee JH, Lee MH, Lee T. Fabrication of Electrochemical Influenza Virus (H1N1) Biosensor Composed of Multifunctional DNA Four-Way Junction and Molybdenum Disulfide Hybrid Material. MATERIALS (BASEL, SWITZERLAND) 2021; 14:E343. [PMID: 33445498 PMCID: PMC7827127 DOI: 10.3390/ma14020343] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 12/23/2020] [Accepted: 01/07/2021] [Indexed: 11/16/2022]
Abstract
The outbreak of the influenza virus (H1N1) has symptoms such as coughing, fever, and a sore throat, and due to its high contagious power, it is fatal to humans. To detect H1N1 precisely, the present study proposed an electrochemical biosensor composed of a multifunctional DNA four-way junction (4WJ) and carboxyl molybdenum disulfide (carboxyl-MoS2) hybrid material. The DNA 4WJ was constructed to have the hemagglutinin aptamer on the head group (recognition part); each of the two arms has four silver ions (signal amplification part), and the tail group has an amine group (anchor). This fabricated multifunctional DNA 4WJ can specifically and selectively bind to hemagglutinin. Moreover, the carboxyl-MoS2 provides an increase in the sensitivity of this biosensor. Carboxyl-MoS2 was immobilized using a linker on the electrode, followed by the immobilization of the multifunctional 4WJ on the electrode. The synthesis of carboxyl-MoS2 was confirmed by field emission scanning electron microscopy (FE-SEM), and the surface of the electrode was confirmed by atomic force microscopy. When H1N1 was placed in the immobilized electrode, the presence of H1N1 was confirmed by electrochemical analysis (cyclic voltammetry, electrochemical impedance spectroscopy). Through selectivity tests, it was also possible to determine whether this sensor responds specifically and selectively to H1N1. We confirmed that the biosensor showed a linear response to H1N1, and that H1N1 could be detected from 100 nM to 10 pM. Finally, clinical tests, in which hemagglutinin was diluted with human serum, showed a similar tendency to those diluted with water. This study showed that the multi-functional DNA 4WJ and carboxyl-MoS2 hybrid material can be applied to a electrochemical H1N1 biosensor.
Collapse
Affiliation(s)
- Jeong Ah Park
- Department of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul 01897, Korea; (J.A.P.); (J.K.); (S.M.K.); (H.S.); (C.P.)
| | - Jinmyeong Kim
- Department of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul 01897, Korea; (J.A.P.); (J.K.); (S.M.K.); (H.S.); (C.P.)
| | - Soo Min Kim
- Department of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul 01897, Korea; (J.A.P.); (J.K.); (S.M.K.); (H.S.); (C.P.)
| | - Hiesang Sohn
- Department of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul 01897, Korea; (J.A.P.); (J.K.); (S.M.K.); (H.S.); (C.P.)
| | - Chulhwan Park
- Department of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul 01897, Korea; (J.A.P.); (J.K.); (S.M.K.); (H.S.); (C.P.)
| | - Tae-Hyung Kim
- School of Integrative Engineering, Chung-Ang University, 84, Heukseok-ro, Seoul 06974, Korea;
| | - Jin-Ho Lee
- School of Biomedical Convergence Engineering, Pusan National University, 49, Busandaehak-ro, Yangsan 50612, Korea;
| | - Min-Ho Lee
- School of Integrative Engineering, Chung-Ang University, 84, Heukseok-ro, Seoul 06974, Korea;
| | - Taek Lee
- Department of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-Ro, Seoul 01897, Korea; (J.A.P.); (J.K.); (S.M.K.); (H.S.); (C.P.)
| |
Collapse
|
10
|
Khoris IM, Ganganboina AB, Suzuki T, Park EY. Self-assembled chromogen-loaded polymeric cocoon for respiratory virus detection. NANOSCALE 2021; 13:388-396. [PMID: 33351018 DOI: 10.1039/d0nr06893d] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Inspired by the self-assembly approach, in this work, the chromogen, 3,3',5,5'-tetramethylbenzidine (TMB), was successfully co-precipitated in aqueous solution to form collective nanoparticles (NPs) of signal molecules (TMB-NPs). Utilizing poly(lactide-co-glycolide) (PLGA) in the molecular delivery approach, the formed emulsion nanovesicle (TMB-NPs@PLGA) exhibits an enrichment of the collective signal molecules in a single antibody-antigen conjugation. A specific antibody-conjugated TMB-NPs@PLGA forms an immunocomplex sandwich structure upon the addition of influenza virus (IV)/A. The addition of dimethyl sulfoxide (DMSO) dissolves the PLGA nanovesicles, releasing the encapsulated TMB-NPs. Sequentially, the TMB-NPs release TMB molecules upon the addition of DMSO. The released TMB is catalytically oxidized by H2O2 with self-assembled protein-inorganic nanoflowers, where copper nanoflowers (CuNFs) acted as the nanozyme. The developed immunoassay demonstrates high sensitivity for IV/A with a limit of detection (LOD) as low as 32.37 fg mL-1 and 54.97 fg mL-1 in buffer and serum, respectively. For practical needs, a clinically isolated IV/A/H3N2 and spike protein of SARS-CoV-2 were detected with the LODs of 17 pfu mL-1 and 143 fg mL-1, respectively. These results show the applicability of the advanced TMB-NPs@PLGA-based colorimetric sensor for the highly sensitive detection of airborne respiratory viruses.
Collapse
Affiliation(s)
- Indra Memdi Khoris
- Department of Bioscience, Graduate School of Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka 422-8529, Japan.
| | | | | | | |
Collapse
|
11
|
Demeke Teklemariam A, Samaddar M, Alharbi MG, Al-Hindi RR, Bhunia AK. Biosensor and molecular-based methods for the detection of human coronaviruses: A review. Mol Cell Probes 2020; 54:101662. [PMID: 32911064 PMCID: PMC7477626 DOI: 10.1016/j.mcp.2020.101662] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 09/02/2020] [Accepted: 09/02/2020] [Indexed: 12/28/2022]
Abstract
The ongoing crisis due to the global pandemic caused by a highly contagious coronavirus (Coronavirus disease - 2019; COVID-19) and the lack of either proven effective therapy or a vaccine has made diagnostic a valuable tool in disease tracking and prevention. The complex nature of this newly emerging virus calls for scientists' attention to find the most reliable, highly sensitive, and selective detection techniques for better control or spread of the disease. Reverse transcriptase-polymerase chain reaction (RT-PCR) and serology-based tests are currently being used. However, the speed and accuracy of these tests may not meet the current demand; thus, alternative technology platforms are being developed. Nano biosensor technology platforms have been established as a promising diagnostic tool for rapid and accurate detection of viruses as well as other life-threatening diseases even in resource-limited settings. This review aims to provide a short overview of recent advancements in molecular and biosensor-based diagnosis of viruses, including the human coronaviruses, and highlight the challenges and future perspectives of these detection technologies.
Collapse
Affiliation(s)
- Addisu Demeke Teklemariam
- Department of Biological Sciences, Faculty of Science, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Manalee Samaddar
- Department of Food Science, Purdue University, West Lafayette, 47907, IN, USA; Purdue Institute of Inflammation, Immunology and Infectious Disease, Purdue University, West Lafayette, 47907, IN, USA
| | - Mona G Alharbi
- Department of Biological Sciences, Faculty of Science, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Rashad R Al-Hindi
- Department of Biological Sciences, Faculty of Science, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Arun K Bhunia
- Department of Food Science, Purdue University, West Lafayette, 47907, IN, USA; Department of Comparative Pathobiology, Purdue University, West Lafayette, 47907, IN, USA; Purdue Institute of Inflammation, Immunology and Infectious Disease, Purdue University, West Lafayette, 47907, IN, USA.
| |
Collapse
|
12
|
The Latest Achievements in the Construction of Influenza Virus Detection Aptasensors. Viruses 2020; 12:v12121365. [PMID: 33265901 PMCID: PMC7760490 DOI: 10.3390/v12121365] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 11/14/2020] [Accepted: 11/23/2020] [Indexed: 12/14/2022] Open
Abstract
Aptamers are short fragments of nucleic acids, DNA or RNA that have the ability to bind selected proteins with high specificity and affinity. These properties allow them to be used as an element of biosensors for the detection of specific proteins, including viral ones, which makes it possible to design valuable diagnostic tools. The influenza virus causes a huge number of human and animal deaths worldwide every year, and contributes to remarkable economic losses. In addition, in 2020, a new threat appeared-the SARS-Cov-2 pandemic. Both disease entities, especially in the initial stage of infection, are almost identical in terms of signs and symptoms. Therefore, a diagnostic solution is needed that will allow distinguishing between both pathogens, with high sensitivity and specificity; it should be cheap, quick and possible to use in the field, for example, in a doctor's office. All the mentioned properties are met by aptasensors in which the detection elements are specific aptamers. We present here the latest developments in the construction of various types of aptasensors for the detection of influenza virus. Aptasensor operation is based on the measurement of changes in electric impedance, fluorescence or electric signal (impedimetric, fluorescence and electrochemical aptasensors, respectively); it allows both qualitative and quantitative determinations. The particularly high advancement for detecting of influenza virus concerns impedimetric aptasensors.
Collapse
|
13
|
Fluorescent and electrochemical dual-mode detection of Chikungunya virus E1 protein using fluorophore-embedded and redox probe-encapsulated liposomes. Mikrochim Acta 2020; 187:674. [PMID: 33241435 PMCID: PMC7688297 DOI: 10.1007/s00604-020-04656-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Accepted: 11/18/2020] [Indexed: 11/16/2022]
Abstract
The critical goal of sensitive virus detection should apply in the early stage of infection, which may increase the probable survival rate. To achieve the low detection limit for the early stage where a small number of viruses are present in the sample, proper amplified signals from a sensor can make readable and reliable detection. In this work, a new model of fluorescent and electrochemical dual-mode detection system has been developed to detect virus, taking recombinant Chikungunya virus E1 protein (CHIK-VP) as an example. The hydrophobic quantum dots (QDs) embedded in the lipid bilayer of liposome and methylene blue (MB) encapsulated in the inner core of liposomes played a role of dual-signaling modulator. After CHIK-VP addition, the nanocomposites and APTES-coated Fe3O4 nanoparticles (Fe3O4 NPs) were conjugated with antibodies to form a sandwich structure and separated from the medium magnetically. The nanoconjugates have been burst out by chloroform as surfactant, and both the QDs and MB are released from the liposome and were then monitored through changes in the fluorescence and electrochemical signals, respectively. These two fluorometric and electrochemical signals alteration quantified the CHIK-VP in the range of femtogram to nanogram per milliliter level with a LOD of 32 fg mL−1, making this liposomal system a potential matrix in a virus detection platform. Graphical abstract ![]()
Collapse
|
14
|
Gulati S, Singh P, Diwan A, Mongia A, Kumar S. Functionalized gold nanoparticles: promising and efficient diagnostic and therapeutic tools for HIV/AIDS. RSC Med Chem 2020; 11:1252-1266. [PMID: 34095839 PMCID: PMC8126886 DOI: 10.1039/d0md00298d] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Accepted: 08/31/2020] [Indexed: 02/05/2023] Open
Abstract
Functionalized gold nanoparticles are recognized as promising vehicles in the diagnosis and treatment of human immunodeficiency virus (HIV) owing to their excellent biocompatibility with biomolecules (like DNA or RNA), their potential for multivalency and their unique optical and structural properties. In this context, this review article focuses on the diverse detection abilities and delivery and uptake methodologies of HIV by targeting genes and proteins using gold nanoparticles on the basis of different shapes and sizes in order to promote its effective expression. In addition, recent trends in gold nanoparticle mediated HIV detection, delivery and uptake and treatment are highlighted considering their cytotoxic effects on healthy human cells.
Collapse
Affiliation(s)
- Shikha Gulati
- Department of Chemistry, Sri Venkateswara College, University of Delhi Delhi-110021 India
| | - Parinita Singh
- Department of Chemistry, Sri Venkateswara College, University of Delhi Delhi-110021 India
| | - Anchita Diwan
- Department of Chemistry, Sri Venkateswara College, University of Delhi Delhi-110021 India
| | - Ayush Mongia
- Department of Chemistry, Sri Venkateswara College, University of Delhi Delhi-110021 India
| | - Sanjay Kumar
- Department of Chemistry, Sri Venkateswara College, University of Delhi Delhi-110021 India
| |
Collapse
|
15
|
Achadu OJ, Takemura K, Khoris IM, Park EY. Plasmonic/magnetic molybdenum trioxide and graphitic carbon nitride quantum dots-based fluoroimmunosensing system for influenza virus. SENSORS AND ACTUATORS. B, CHEMICAL 2020; 321:128494. [PMID: 32834503 PMCID: PMC7313904 DOI: 10.1016/j.snb.2020.128494] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 05/30/2020] [Accepted: 06/20/2020] [Indexed: 05/12/2023]
Abstract
A novel magnetic/plasmonic-assisted fluoro-immunoassay system is developed for the detection of influenza virus using magnetic-derivatized plasmonic molybdenum trioxide quantum dots (MP-MoO3 QDs) as the plasmonic/magnetic agent and fluorescent graphitic carbon nitride quantum dots (gCNQDs) as the monitoring probe. Specific antibody against influenza A virus was conjugated onto the surface of MP-MoO3 QDs and gCNQDs, respectively. In the presence of influenza A virus (as the test virus), a core-satellite immunocomplex is formed between the antibody-conjugated nanomaterials (Ab-MP-MoO3 QDs and Ab-gCNQDs) and their interaction resulted in the modulation and gradual enhancement of the fluorescence intensity of the detection probe with the influenza virus concentration-dependent increase. In addition, PL change without influenza A virus was not observed. Limits of detection of 0.25 and 0.9 pg/mL were achieved for Influenza virus A/New Caledonia (20/99/IVR/116) (H1N1) detection in deionized water and human serum, respectively. Clinically isolated influenza virus A/Yokohama (110/2009) (H3N2) was detected in the range of 45 - 25,000 PFU/mL, with a limit of detection ca 45 PFU/mL (as opposed to a minimum of 5000 PFU/mL for a commercial test kit). This developed biosensor provides a robust, sensitive as well as a selective platform for influenza virus detection.
Collapse
Affiliation(s)
- Ojodomo J. Achadu
- Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka, 422-8529, Japan
| | - Kenshin Takemura
- Laboratory of Biotechnology, Department of Bioscience, Graduate School of Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka, 422-8529, Japan
| | - Indra Memdi Khoris
- Laboratory of Biotechnology, Department of Bioscience, Graduate School of Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka, 422-8529, Japan
| | - Enoch Y. Park
- Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka, 422-8529, Japan
- Laboratory of Biotechnology, Department of Bioscience, Graduate School of Science and Technology, Shizuoka University, 836 Ohya Suruga-ku, Shizuoka, 422-8529, Japan
- Corresponding author.
| |
Collapse
|
16
|
Zhang L, Mazouzi Y, Salmain M, Liedberg B, Boujday S. Antibody-Gold Nanoparticle Bioconjugates for Biosensors: Synthesis, Characterization and Selected Applications. Biosens Bioelectron 2020; 165:112370. [DOI: 10.1016/j.bios.2020.112370] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 06/04/2020] [Accepted: 06/05/2020] [Indexed: 01/22/2023]
|
17
|
Badshah MA, Koh NY, Zia AW, Abbas N, Zahra Z, Saleem MW. Recent Developments in Plasmonic Nanostructures for Metal Enhanced Fluorescence-Based Biosensing. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E1749. [PMID: 32899375 PMCID: PMC7558009 DOI: 10.3390/nano10091749] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 08/27/2020] [Accepted: 08/31/2020] [Indexed: 01/14/2023]
Abstract
Metal-enhanced fluorescence (MEF) is a unique phenomenon of surface plasmons, where light interacts with the metallic nanostructures and produces electromagnetic fields to enhance the sensitivity of fluorescence-based detection. In particular, this enhancement in sensing capacity is of importance to many research areas, including medical diagnostics, forensic science, and biotechnology. The article covers the basic mechanism of MEF and recent developments in plasmonic nanostructures fabrication for efficient fluorescence signal enhancement that are critically reviewed. The implications of current fluorescence-based technologies for biosensors are summarized, which are in practice to detect different analytes relevant to food control, medical diagnostics, and forensic science. Furthermore, characteristics of existing fabrication methods have been compared on the basis of their resolution, design flexibility, and throughput. The future projections emphasize exploring the potential of non-conventional materials and hybrid fabrication techniques to further enhance the sensitivity of MEF-based biosensors.
Collapse
Affiliation(s)
- Mohsin Ali Badshah
- Department of Chemical and Biomolecular Engineering, University of California-Irvine, Irvine, CA 92697, USA
| | - Na Yoon Koh
- Plamica Labs, Batten Hall, 125 Western Ave, Allston, MA 02163, USA;
| | - Abdul Wasy Zia
- Institute of Structural Health Management, Faculty of Civil Engineering and Engineering Mechanics, Jiangsu University, Zhenjiang 212013, China;
| | - Naseem Abbas
- School of Mechanical Engineering, Chung-Ang University, Seoul 06974, Korea;
| | - Zahra Zahra
- Department of Civil & Environmental Engineering, University of California-Irvine, Irvine, CA 92697, USA;
| | - Muhammad Wajid Saleem
- Department of Mechanical Engineering, University of Engineering and Technology, Lahore 54890, Pakistan;
| |
Collapse
|
18
|
Nasrin F, Chowdhury AD, Takemura K, Kozaki I, Honda H, Adegoke O, Park EY. Fluorometric virus detection platform using quantum dots-gold nanocomposites optimizing the linker length variation. Anal Chim Acta 2020; 1109:148-157. [PMID: 32252898 DOI: 10.1016/j.aca.2020.02.039] [Citation(s) in RCA: 46] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 02/17/2020] [Accepted: 02/19/2020] [Indexed: 01/24/2023]
Abstract
In this study, a tunable biosensor using the localized surface plasmon resonance (LSPR), controlling the distance between fluorescent CdZnSeS/ZnSeS quantum dots (QDs) and gold nanoparticles (AuNPs) has been developed for the detection of virus. The distance between the AuNPs and QDs has been controlled by a linkage with a peptide chain of 18 amino acids. In the optimized condition, the fluorescent properties of the QDs have been enhanced due to the surface plasmon effect of the adjacent AuNPs. Successive virus binding on the peptide chain induces steric hindrance on the LSPR behavior and the fluorescence of QDs has been quenched. After analyzing all the possible aspect of the CdZnSeS/ZnSeS QD-peptide-AuNP nanocomposites, we have detected different concentration of influenza virus in a linear range of 10-14 to 10-9 g mL-1 with detection limit of 17.02 fg mL-1. On the basis of the obtained results, this proposed biosensor can be a good alternative for the detection of infectious viruses in the various range of sensing application.
Collapse
Affiliation(s)
- Fahmida Nasrin
- Laboratory of Biotechnology, Graduate School of Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka, 422-8529, Japan.
| | - Ankan Dutta Chowdhury
- Laboratory of Biotechnology, Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka, 422-8529, Japan.
| | - Kenshin Takemura
- Laboratory of Biotechnology, Graduate School of Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka, 422-8529, Japan.
| | - Ikko Kozaki
- Department of Biomolecular Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, 464-8603, Japan.
| | - Hiroyuki Honda
- Department of Biomolecular Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, 464-8603, Japan.
| | - Oluwasesan Adegoke
- Laboratory of Biotechnology, Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka, 422-8529, Japan.
| | - Enoch Y Park
- Laboratory of Biotechnology, Graduate School of Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka, 422-8529, Japan; Laboratory of Biotechnology, Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka, 422-8529, Japan.
| |
Collapse
|
19
|
Nasrin F, Chowdhury AD, Takemura K, Lee J, Adegoke O, Deo VK, Abe F, Suzuki T, Park EY. Single-step detection of norovirus tuning localized surface plasmon resonance-induced optical signal between gold nanoparticles and quantum dots. Biosens Bioelectron 2018; 122:16-24. [PMID: 30236804 DOI: 10.1016/j.bios.2018.09.024] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Revised: 08/21/2018] [Accepted: 09/06/2018] [Indexed: 12/30/2022]
Abstract
A new method of label free sensing approach with superior selectivity and sensitivity towards virlabel-freeon is presented here, employing the localized surface plasmon resonance (LSPR) behavior of gold nanoparticles (AuNPs) and fluorescent CdSeTeS quantum dots (QDs). Inorganic quaternary alloyed CdSeTeS QDs were capped with L-cysteine via a ligand exchange reaction. Alternatively, citrate stabilized AuNPs were functionalized with 11-mercaptoundecanoic acid to generate carboxylic group on the gold surface. The carboxylic group on the AuNPs was subjected to bind covalently with the amine group of L-cysteine capped CdSeTeS QDs to form CdSeTeS QDs/AuNPs nanocomposites. The fluorescence of CdSeTeS QDs/AuNPs nanocomposite shows quenched spectrum of CdSeTeS QDs at 640 nm due to the close interaction with AuNPs. However, after successive addition of norovirus-like particles (NoV-LPs), steric hindrance-induced LSPR signal from the adjacent AuNPs triggered the fluorescence enhancement of QDs in proportion to the concentration of the target NoV-LPs. A linear range of 10-14 to 10-9 g mL-1 NoV-LPs with a detection limit of 12.1 × 10-15 g mL-1 was obtained. This method was further applied on clinically isolated norovirus detection, in the range of 102-105 copies mL-1 with a detection limit of 95.0 copies mL-1, which is 100-fold higher than commercial ELISA kit. The superiority of the proposed sensor over other conventional sensors is found in its ultrasensitive detectability at low virus concentration even in clinically isolated samples. This proposed detection method can pave an avenue for the development of high performance and robust sensing probes for detection of virus in biomedical applications.
Collapse
Affiliation(s)
- Fahmida Nasrin
- Laboratory of Biotechnology, Graduate School of Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| | - Ankan Dutta Chowdhury
- Laboratory of Biotechnology, Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| | - Kenshin Takemura
- Laboratory of Biotechnology, Graduate School of Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| | - Jaewook Lee
- Laboratory of Biotechnology, Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| | - Oluwasesan Adegoke
- Laboratory of Biotechnology, Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| | - Vipin Kumar Deo
- Organization for International Collaboration, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| | - Fuyuki Abe
- Department of Microbiology, Shizuoka Institute of Environment and Hygiene, 4-27-2, Kita-ando, Aoi-ku, Shizuoka 420-8637, Japan.
| | - Tetsuro Suzuki
- Department of Infectious Diseases, Hamamatsu University School of Medicine, 1-20-1 Higashi-ku, Handa-yama, Hamamatsu 431-3192, Japan.
| | - Enoch Y Park
- Laboratory of Biotechnology, Graduate School of Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan; Laboratory of Biotechnology, Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| |
Collapse
|
20
|
Chen HY, Chou C, Chang CH, Lee NG, Yu PC, Chen YC, Pan HC, Fan PC, Yang CW, Cherng WJ, Chen YC. Urine Cofilin-1 Detection for Predicting Type 1 Cardiorenal Syndrome in the Coronary Care Unit: A Gold Nanoparticle- and Laser-Based Approach. Cardiorenal Med 2018; 8:302-310. [PMID: 30121654 DOI: 10.1159/000490927] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Accepted: 06/16/2018] [Indexed: 01/12/2023] Open
Abstract
BACKGROUND Type 1 cardiorenal syndrome (CRS) is a severe complication for acute decompensated heart failure patients. This study aimed at evaluating the feasibility of using the gold nanoparticle-based localized surface plasmon-coupled fluorescence biosensor (LSPCFB) to detect urine cofilin-1 as a biomarker for predicting CRS among patients in the coronary care unit (CCU). METHODS A total of 44 patients were included with prospectively collected urine and blood samples. Both LSPCFB and conventional enzyme-linked immunosorbent assays (ELISAs) were used to measure urine cofilin-1 at admission to the CCU. The occurrence of CRS was judged within 7 days after admission. The discrimination presented as the area under the receiver operating characteristic curve (AUROC) and calibration of both detection methods were used to assess the predictive ability of urine cofilin-1 measured by the LSPCFB and ELISA. RESULTS Thirteen patients were diagnosed with CRS, while the other 31 patients were classified into a non-CRS group. For predicting CRS by measuring urine cofilin-1, the LSPCFB had higher accuracy (AUROC: 0.707, p = 0.031; overall accuracy: 79.55%) than the ELISA (AUROC: 0.479, p = 0.827; overall accuracy: 53.27%). The positive and negative predictive values of the LSPCFB were also higher than those of the ELISA (positive predictive value: 70.0 vs. 34.8%; negative predictive value: 82.4 vs. 76.2%). CONCLUSIONS The gold nanoparticle-based immunoassay LSPCFB could exploit the potential of urine cofilin-1 as a single biomarker to predict CRS among CCU patients.
Collapse
Affiliation(s)
- Hsing-Yu Chen
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan.,Division of Chinese Internal Medicine, Center for Traditional Chinese Medicine, Chang Gung Memorial Hospital, Taoyuan, Taiwan.,School of Traditional Chinese Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Chien Chou
- Graduate Institute of Electro-Optical Engineering, Chang Gung University, Taoyuan, Taiwan
| | - Chih-Hsiang Chang
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan.,Kidney Research Center, Department of Nephrology, Chang Gung Memorial Hospital, Linkou, Taiwan.,College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Nien-Gen Lee
- Graduate Institute of Electro-Optical Engineering, Chang Gung University, Taoyuan, Taiwan
| | - Pei-Chun Yu
- Graduate Institute of Electro-Optical Engineering, Chang Gung University, Taoyuan, Taiwan
| | - Yu-Chi Chen
- Graduate Institute of Electro-Optical Engineering, Chang Gung University, Taoyuan, Taiwan
| | - Heng-Chih Pan
- Division of Nephrology, Department of Internal Medicine, Chang Gung Memorial Hospital, Keelung, Taiwan
| | - Pei-Chun Fan
- Graduate Institute of Clinical Medical Sciences, College of Medicine, Chang Gung University, Taoyuan, Taiwan.,Kidney Research Center, Department of Nephrology, Chang Gung Memorial Hospital, Linkou, Taiwan.,College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Chih-Wei Yang
- Kidney Research Center, Department of Nephrology, Chang Gung Memorial Hospital, Linkou, Taiwan.,College of Medicine, Chang Gung University, Taoyuan, Taiwan
| | - Wen-Jin Cherng
- College of Medicine, Chang Gung University, Taoyuan, Taiwan.,Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Keelung, Taiwan
| | - Yung-Chang Chen
- College of Medicine, Chang Gung University, Taoyuan, Taiwan.,Division of Nephrology, Department of Internal Medicine, Chang Gung Memorial Hospital, Keelung, Taiwan.,Community Medicine Research Center, Chang Gung Memorial Hospital, Keelung, Taiwan
| |
Collapse
|
21
|
Draz MS, Shafiee H. Applications of gold nanoparticles in virus detection. Theranostics 2018; 8:1985-2017. [PMID: 29556369 PMCID: PMC5858513 DOI: 10.7150/thno.23856] [Citation(s) in RCA: 160] [Impact Index Per Article: 26.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Accepted: 01/09/2018] [Indexed: 12/12/2022] Open
Abstract
Viruses are the smallest known microbes, yet they cause the most significant losses in human health. Most of the time, the best-known cure for viruses is the innate immunological defense system of the host; otherwise, the initial prevention of viral infection is the only alternative. Therefore, diagnosis is the primary strategy toward the overarching goal of virus control and elimination. The introduction of a new class of nanoscale materials with multiple unique properties and functions has sparked a series of breakthrough applications. Gold nanoparticles (AuNPs) are widely reported to guide an impressive resurgence in biomedical and diagnostic applications. Here, we review the applications of AuNPs in virus testing and detection. The developed AuNP-based detection techniques are reported for various groups of clinically relevant viruses with a special focus on the applied types of bio-AuNP hybrid structures, virus detection targets, and assay modalities and formats. We pay particular attention to highlighting the functional role and activity of each core Au nanostructure and the resultant detection improvements in terms of sensitivity, detection range, and time. In addition, we provide a general summary of the contributions of AuNPs to the mainstream methods of virus detection, technical measures, and recommendations required in guidance toward commercial in-field applications.
Collapse
Affiliation(s)
- Mohamed Shehata Draz
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts 02115
- Department of Medicine, Harvard Medical School, Boston, MA 02115, USA
- Faculty of Science, Tanta University, Tanta 31527, Egypt
| | - Hadi Shafiee
- Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts 02115
- Department of Medicine, Harvard Medical School, Boston, MA 02115, USA
| |
Collapse
|
22
|
Hassanpour S, Baradaran B, Hejazi M, Hasanzadeh M, Mokhtarzadeh A, de la Guardia M. Recent trends in rapid detection of influenza infections by bio and nanobiosensor. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2017.11.012] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
23
|
Wang SF, Tseng SP, Loh EW, Wang WH, Li MC, Chen KH, Tsai WC, Lee YM, Chen HY, Liu FT, Arthur Chen YM, Huang JC. Generation and characterization of new monoclonal antibodies against swine origin 2009 influenza A (H1N1) virus and evaluation of their prophylactic and therapeutic efficacy in a mouse model. DEVELOPMENTAL AND COMPARATIVE IMMUNOLOGY 2017; 67:8-17. [PMID: 27984103 DOI: 10.1016/j.dci.2016.10.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2016] [Revised: 10/25/2016] [Accepted: 10/25/2016] [Indexed: 06/06/2023]
Abstract
In 2009, a swine-origin influenza A virus - A(H1N1)pdm09 - emerged and has became a pandemic strain circulating worldwide. The hemagglutinin (HA) of influenza virus is a potential target for the development of anti-viral therapeutic agents. Here, we generated mAbs by immunization of baculovirus-insect expressing trimeric recombinant HA of the A(H1N1)pdm09 strain. Results indicated that the mAbs recognized two novel neutralizing and protective epitopes-"STAS" and "FRSK" which located near Cb and Ca1 antigenic regions respectively and were conserved in almost 2009-2016 influenza H1N1 stains. The mAb 12E11 demonstrated higher protective efficacy than mAb 8B10 in mice challenge assay. Both mAb pretreatments significantly reduced virus titers and pro-inflammatory cytokines in mice lung postinfection (p < 0.01), and showed prophylactic and therapeutic efficacies even 48 h postinfection (p < 0.05). Combination therapy using the mAbs with oseltamivir pre- and post-treatment showed synergistic therapeutic effect in mice model (p < 0.01). Further investigation for clinical application in humans is warranted.
Collapse
Affiliation(s)
- Sheng-Fan Wang
- Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung 80708, Taiwan; Center for Infectious Disease and Cancer Research, Kaohsiung Medical University, Kaohsiung 80708, Taiwan.
| | - Sung-Pin Tseng
- Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung 80708, Taiwan
| | - El-Wui Loh
- Center for Evidence-based Health Care, Taipei Medical University, Shuang Ho Hospital, New Taipei City 23561, Taiwan
| | - Wen-Hung Wang
- Department of Medicine, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung 80708, Taiwan
| | - Ming-Chun Li
- Department of Pediatrics, Taipei City Hospital, Yang-Ming Branch, Taipei 11146, Taiwan
| | - Kuan-Hsuan Chen
- Center for Infectious Disease and Cancer Research, Kaohsiung Medical University, Kaohsiung 80708, Taiwan
| | - Wan-Chi Tsai
- Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung 80708, Taiwan
| | - Yuan-Ming Lee
- Department of Laboratory Medicine, National Yang-Ming University Hospital, Yi-Lan 260, Taiwan
| | - Huan-Yuan Chen
- Institute of Biomedical Sciences, Academia Sinica, Taipei 11578, Taiwan; Department of Dermatology, University of California at Davis, CA 95816, USA
| | - Fu-Tong Liu
- Institute of Biomedical Sciences, Academia Sinica, Taipei 11578, Taiwan; Department of Dermatology, University of California at Davis, CA 95816, USA
| | - Yi-Ming Arthur Chen
- Center for Infectious Disease and Cancer Research, Kaohsiung Medical University, Kaohsiung 80708, Taiwan; Department of Microbiology, College of Medicine, Kaohsiung Medical University, Kaohsiung 80708, Taiwan.
| | - Jason C Huang
- Department of Biotechnology and Laboratory Science in Medicine, National Yang-Ming University, Taipei 11272, Taiwan; AIDS Prevention and Research Center, National Yang-Ming University, Taipei 11272, Taiwan.
| |
Collapse
|
24
|
Takemura K, Adegoke O, Takahashi N, Kato T, Li TC, Kitamoto N, Tanaka T, Suzuki T, Park EY. Versatility of a localized surface plasmon resonance-based gold nanoparticle-alloyed quantum dot nanobiosensor for immunofluorescence detection of viruses. Biosens Bioelectron 2016; 89:998-1005. [PMID: 27825520 DOI: 10.1016/j.bios.2016.10.045] [Citation(s) in RCA: 86] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2016] [Revised: 10/08/2016] [Accepted: 10/19/2016] [Indexed: 10/20/2022]
Abstract
Flu infection, caused by the influenza virus, constitutes a serious threat to human lives worldwide. A rapid, sensitive and specific diagnosis is urgently needed for point-of-care treatment and to control the rapid spread of this disease. In this study, an ultrasensitive, rapid and specific localized surface plasmon resonance (LSPR)-induced immunofluorescence nanobiosensor has been developed for the influenza virus based on a gold nanoparticle (AuNP)-induced quantum dot (QD) fluorescence signal. Alloyed quaternary CdSeTeS QDs were synthesized via the hot-injection organometallic route and were subsequently capped with l-cysteine via a ligand exchange reaction. AuNPs were synthesized in HEPES buffer and thiolated with l-cysteine. The concept of the biosensor involves the conjugation of anti-neuraminidase (NA) antibody (anti-NA Ab) to thiolated AuNPs and the conjugation of anti-hemagglutinin (HA) antibody (anti-HA Ab) to alloyed quaternary l-cysteine-capped CdSeTeS QDs. Interaction of the antigens displaying on the surface of the influenza virus target with anti-NA Ab-conjugated AuNPs and anti-HA Ab-conjugated QDs induces an LSPR signal from adjacent AuNPs to trigger fluorescence-enhancement changes in the QDs in proportion to the concentration of the target virus. The detection limit for influenza H1N1 virus was 0.03pg/mL in deionized water and 0.4pg/mL in human serum; while, for the clinically isolated H3N2, the detection limit was 10PFU/mL. The detection of influenza virus H1N1 was accomplished with high sensitivity. The versatility of the biosensor was demonstrated for the detection of clinically isolated influenza virus H3N2 and norovirus-like particles (NoV-LPs).
Collapse
Affiliation(s)
- Kenshin Takemura
- Laboratory of Biotechnology, Department of Agriculture, Graduate School of Integrated Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| | - Oluwasesan Adegoke
- Laboratory of Biotechnology, Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| | - Naoto Takahashi
- Laboratory of Biotechnology, Department of Agriculture, Graduate School of Integrated Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| | - Tatsuya Kato
- Laboratory of Biotechnology, Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan; College of Agriculture, Academic Institute, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| | - Tian-Cheng Li
- Department of Virology II, National Institute of Infectious Diseases, Gakuen 4-7-1, Musashi-Murayama, Tokyo 208-0011, Japan.
| | - Noritoshi Kitamoto
- School of Human Science and Environment, University of Hyogo, 1-1-12 Shinzaike-Honcho, Himeji, Hyogo 670-0092, Japan.
| | | | - Tetsuro Suzuki
- Department of Infectious Diseases, Hamamatsu University School of Medicine, 1-20-1 Higashi-ku, Handa-yama, Hamamatsu 431-3192, Japan.
| | - Enoch Y Park
- Laboratory of Biotechnology, Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan; College of Agriculture, Academic Institute, Shizuoka University, 836 Ohya, Suruga-ku, Shizuoka 422-8529, Japan.
| |
Collapse
|
25
|
Use of liposomal amplifiers in total internal reflection fluorescence fiber-optic biosensors for protein detection. Biosens Bioelectron 2016; 77:1201-7. [DOI: 10.1016/j.bios.2015.10.012] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2015] [Revised: 10/02/2015] [Accepted: 10/04/2015] [Indexed: 11/23/2022]
|
26
|
Lum J, Wang R, Hargis B, Tung S, Bottje W, Lu H, Li Y. An Impedance Aptasensor with Microfluidic Chips for Specific Detection of H5N1 Avian Influenza Virus. SENSORS 2015; 15:18565-78. [PMID: 26230699 PMCID: PMC4570336 DOI: 10.3390/s150818565] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2015] [Revised: 07/17/2015] [Accepted: 07/21/2015] [Indexed: 12/20/2022]
Abstract
In this research a DNA aptamer, which was selected through SELEX (systematic evolution of ligands by exponential enrichment) to be specific against the H5N1 subtype of the avian influenza virus (AIV), was used as an alternative reagent to monoclonal antibodies in an impedance biosensor utilizing a microfluidics flow cell and an interdigitated microelectrode for the specific detection of H5N1 AIV. The gold surface of the interdigitated microelectrode embedded in a microfluidics flow cell was modified using streptavidin. The biotinylated aptamer against H5N1 was then immobilized on the electrode surface using biotin-streptavidin binding. The target virus was captured on the microelectrode surface, causing an increase in impedance magnitude. The aptasensor had a detection time of 30 min with a detection limit of 0.0128 hemagglutinin units (HAU). Scanning electron microscopy confirmed the binding of the target virus onto the electrode surface. The DNA aptamer was specific to H5N1 and had no cross-reaction to other subtypes of AIV (e.g., H1N1, H2N2, H7N2). The newly developed aptasensor offers a portable, rapid, low-cost alternative to current methods with the same sensitivity and specificity.
Collapse
Affiliation(s)
- Jacob Lum
- Cell and Molecular Biology Program, University of Arkansas, Fayetteville, AR 72701, USA.
| | - Ronghui Wang
- Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, AR 72701, USA.
| | - Billy Hargis
- Department of Poultry Science, University of Arkansas, Fayetteville, AR 72701, USA.
| | - Steve Tung
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR 72701, USA.
| | - Walter Bottje
- Department of Poultry Science, University of Arkansas, Fayetteville, AR 72701, USA.
| | - Huaguang Lu
- Animal Diagnostic Laboratory, Pennsylvania State University, University Park, PA 16802, USA.
| | - Yanbin Li
- Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, AR 72701, USA.
- Department of Poultry Science, University of Arkansas, Fayetteville, AR 72701, USA.
| |
Collapse
|
27
|
Localized Surface Plasmon Resonance Biosensing: Current Challenges and Approaches. SENSORS 2015; 15:15684-716. [PMID: 26147727 PMCID: PMC4541850 DOI: 10.3390/s150715684] [Citation(s) in RCA: 222] [Impact Index Per Article: 24.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/17/2015] [Revised: 06/13/2015] [Accepted: 06/23/2015] [Indexed: 12/16/2022]
Abstract
Localized surface plasmon resonance (LSPR) has emerged as a leader among label-free biosensing techniques in that it offers sensitive, robust, and facile detection. Traditional LSPR-based biosensing utilizes the sensitivity of the plasmon frequency to changes in local index of refraction at the nanoparticle surface. Although surface plasmon resonance technologies are now widely used to measure biomolecular interactions, several challenges remain. In this article, we have categorized these challenges into four categories: improving sensitivity and limit of detection, selectivity in complex biological solutions, sensitive detection of membrane-associated species, and the adaptation of sensing elements for point-of-care diagnostic devices. The first section of this article will involve a conceptual discussion of surface plasmon resonance and the factors affecting changes in optical signal detected. The following sections will discuss applications of LSPR biosensing with an emphasis on recent advances and approaches to overcome the four limitations mentioned above. First, improvements in limit of detection through various amplification strategies will be highlighted. The second section will involve advances to improve selectivity in complex media through self-assembled monolayers, “plasmon ruler” devices involving plasmonic coupling, and shape complementarity on the nanoparticle surface. The following section will describe various LSPR platforms designed for the sensitive detection of membrane-associated species. Finally, recent advances towards multiplexed and microfluidic LSPR-based devices for inexpensive, rapid, point-of-care diagnostics will be discussed.
Collapse
|
28
|
Yang ZH, Zhuo Y, Yuan R, Chai YQ. An amplified electrochemical immunosensor based on in situ-produced 1-naphthol as electroactive substance and graphene oxide and Pt nanoparticles functionalized CeO2 nanocomposites as signal enhancer. Biosens Bioelectron 2015; 69:321-7. [DOI: 10.1016/j.bios.2015.01.035] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2014] [Revised: 01/05/2015] [Accepted: 01/16/2015] [Indexed: 12/23/2022]
|
29
|
Lee JH, Oh BK, Choi JW. Development of a HIV-1 Virus Detection System Based on Nanotechnology. SENSORS 2015; 15:9915-27. [PMID: 25923937 PMCID: PMC4481885 DOI: 10.3390/s150509915] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2015] [Revised: 04/08/2015] [Accepted: 04/20/2015] [Indexed: 12/27/2022]
Abstract
Development of a sensitive and selective detection system for pathogenic viral agents is essential for medical healthcare from diagnostics to therapeutics. However, conventional detection systems are time consuming, resource-intensive and tedious to perform. Hence, the demand for sensitive and selective detection system for virus are highly increasing. To attain this aim, different aspects and techniques have been applied to develop virus sensor with improved sensitivity and selectivity. Here, among those aspects and techniques, this article reviews HIV virus particle detection systems incorporated with nanotechnology to enhance the sensitivity. This review mainly focused on four different detection system including vertically configured electrical detection based on scanning tunneling microscopy (STM), electrochemical detection based on direct electron transfer in virus, optical detection system based on localized surface plasmon resonance (LSPR) and surface enhanced Raman spectroscopy (SERS) using plasmonic nanoparticle.
Collapse
Affiliation(s)
- Jin-Ho Lee
- Department of Chemical & Biomolecular Engineering, Sogang University, #1 Shinsu-Dong, Mapo-Gu, Seoul 121-742, Korea.
| | - Byung-Keun Oh
- Department of Chemical & Biomolecular Engineering, Sogang University, #1 Shinsu-Dong, Mapo-Gu, Seoul 121-742, Korea.
| | - Jeong-Woo Choi
- Department of Chemical & Biomolecular Engineering, Sogang University, #1 Shinsu-Dong, Mapo-Gu, Seoul 121-742, Korea.
| |
Collapse
|
30
|
Amplification of the signal intensity of fluorescence-based fiber-optic biosensors using a Fabry-Perot resonator structure. SENSORS 2015; 15:3565-74. [PMID: 25690548 PMCID: PMC4367373 DOI: 10.3390/s150203565] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2014] [Revised: 01/19/2015] [Accepted: 01/29/2015] [Indexed: 11/17/2022]
Abstract
Fluorescent biosensors have been widely used in biomedical applications. To amplify the intensity of fluorescence signals, this study developed a novel structure for an evanescent wave fiber-optic biosensor by using a Fabry-Perot resonator structure. An excitation light was coupled into the optical fiber through a laser-drilled hole on the proximal end of the resonator. After entering the resonator, the excitation light was reflected back and forth inside the resonator, thereby amplifying the intensity of the light in the fiber. Subsequently, the light was used to excite the fluorescent molecules in the reactive region of the sensor. The experimental results showed that the biosensor signal was amplified eight-fold when the resonator reflector was formed using a 92% reflective coating. Furthermore, in a simulation, the biosensor signal could be amplified 20-fold by using a 99% reflector.
Collapse
|
31
|
Chang YF, Tsao KC, Liu YC, Chen YC, Yu PC, Huang YC, Chou C. Diagnosis of human metapneumovirus in patients hospitalized with acute lower respiratory tract infection using a metal-enhanced fluorescence technique. J Virol Methods 2014; 213:151-6. [PMID: 25522922 DOI: 10.1016/j.jviromet.2014.12.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2014] [Revised: 12/04/2014] [Accepted: 12/05/2014] [Indexed: 11/30/2022]
Abstract
Human metapneumovirus (hMPV) is a common respiratory tract infection in children. However, conventional immunofluorescence assays (IFAs) for detecting hMPV in respiratory samples have limited reliability with a sensitivity and false-negative predictive value of 58.1% and approximately 17.8%, respectively. In this study, hMPV was measured in 91 clinical respiratory samples (55 sputum and 36 nasopharyngeal aspirate samples), which were obtained from children under three years of age, utilizing our previously developed high-throughput metal-enhanced fluorescence (MEF)-based biosensor (HT-MEFB). The sensitivity of HT-MEFB for hMPV detection in the 91 samples was improved by up to 77.4% compared with that obtained with IFAs, and the specificity of HT-MEFB for hMPV detection was 91.7%. In addition, the specificity and accuracy obtained after the selection of 55 sputum samples as the analyzed specimen reached 92.3% and 90.9%, respectively. Thus, in terms of accuracy, high throughput, and sensitivity, HT-MEFB exhibits considerable potential for hMPV detection in clinical settings.
Collapse
Affiliation(s)
- Ying-Feng Chang
- Chang Gung University, Graduate Institute of Electro-Optical Engineering, Taoyuan 33371, Taiwan; National Taiwan University, Department of Biochemical Science and Technology, Taipei 10617, Taiwan
| | - Kuo-Chien Tsao
- Linkou Chang Gung Memorial Hospital, Department of Laboratory Medicine, Taoyuan 33305, Taiwan; Chang Gung University, College of Medicine, Department of Medical Biotechnology and Laboratory Science, Taoyuan 33371, Taiwan
| | - Yi-Chun Liu
- Linkou Chang Gung Memorial Hospital, Department of Laboratory Medicine, Taoyuan 33305, Taiwan
| | - Yu-Chi Chen
- Chang Gung University, Graduate Institute of Electro-Optical Engineering, Taoyuan 33371, Taiwan
| | - Pei-Chun Yu
- Chang Gung University, Graduate Institute of Electro-Optical Engineering, Taoyuan 33371, Taiwan
| | - Yhu-Chering Huang
- Linkou Chang Gung Memorial Hospital, Division of Pediatric Infectious Diseases, Taoyuan 33305, Taiwan; Chang Gung University, College of Medicine, Department of Medicine, Taoyuan 33371, Taiwan
| | - Chien Chou
- Chang Gung University, Graduate Institute of Electro-Optical Engineering, Taoyuan 33371, Taiwan; Chang Gung University, Healthy Aging Research Center, Taoyuan 33302, Taiwan.
| |
Collapse
|
32
|
Chang YF, Hung SH, Su LC, Chen RC, Chou C. Association of HER2 ECD and t-PSA serum levels for possible breast cancer diagnosis. SENSING AND BIO-SENSING RESEARCH 2014. [DOI: 10.1016/j.sbsr.2014.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
33
|
Li Y, Hong M, Qiu B, Lin Z, Chen Y, Cai Z, Chen G. Highly sensitive fluorescent immunosensor for detection of influenza virus based on Ag autocatalysis. Biosens Bioelectron 2014; 54:358-64. [DOI: 10.1016/j.bios.2013.10.045] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2013] [Revised: 10/08/2013] [Accepted: 10/22/2013] [Indexed: 01/08/2023]
|
34
|
Bauch M, Toma K, Toma M, Zhang Q, Dostalek J. Plasmon-Enhanced Fluorescence Biosensors: a Review. PLASMONICS (NORWELL, MASS.) 2014; 9:781-799. [PMID: 27330521 PMCID: PMC4846700 DOI: 10.1007/s11468-013-9660-5] [Citation(s) in RCA: 203] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2013] [Accepted: 12/06/2013] [Indexed: 05/18/2023]
Abstract
Surfaces of metallic films and metallic nanoparticles can strongly confine electromagnetic field through its coupling to propagating or localized surface plasmons. This interaction is associated with large enhancement of the field intensity and local optical density of states which provides means to increase excitation rate, raise quantum yield, and control far field angular distribution of fluorescence light emitted by organic dyes and quantum dots. Such emitters are commonly used as labels in assays for detection of chemical and biological species. Their interaction with surface plasmons allows amplifying fluorescence signal (brightness) that accompanies molecular binding events by several orders of magnitude. In conjunction with interfacial architectures for the specific capture of target analyte on a metallic surface, plasmon-enhanced fluorescence (PEF) that is also referred to as metal-enhanced fluorescence (MEF) represents an attractive method for shortening detection times and increasing sensitivity of various fluorescence-based analytical technologies. This review provides an introduction to fundamentals of PEF, illustrates current developments in design of metallic nanostructures for efficient fluorescence signal amplification that utilizes propagating and localized surface plasmons, and summarizes current implementations to biosensors for detection of trace amounts of biomarkers, toxins, and pathogens that are relevant to medical diagnostics and food control.
Collapse
Affiliation(s)
- Martin Bauch
- AIT-Austrian Institute of Technology GmbH, Muthgasse 11, Vienna, 1190 Austria
| | - Koji Toma
- AIT-Austrian Institute of Technology GmbH, Muthgasse 11, Vienna, 1190 Austria
- Present Address: Forschungszentrum Jülich GmbH, Jülich, 52425 Germany
| | - Mana Toma
- AIT-Austrian Institute of Technology GmbH, Muthgasse 11, Vienna, 1190 Austria
- Present Address: Forschungszentrum Jülich GmbH, Jülich, 52425 Germany
| | - Qingwen Zhang
- AIT-Austrian Institute of Technology GmbH, Muthgasse 11, Vienna, 1190 Austria
- Present Address: Department of Physical Chemistry, School of Chemistry, BIT-Beijing Institute of Technology, Beijing, 100081 China
| | - Jakub Dostalek
- AIT-Austrian Institute of Technology GmbH, Muthgasse 11, Vienna, 1190 Austria
| |
Collapse
|
35
|
Highly sensitive localized surface plasmon resonance immunosensor for label-free detection of HIV-1. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2013; 9:1018-26. [DOI: 10.1016/j.nano.2013.03.005] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2012] [Revised: 03/06/2013] [Accepted: 03/08/2013] [Indexed: 01/28/2023]
|
36
|
Chang YF, Yu JS, Chang YT, Su LC, Wu CC, Chang YS, Lai CS, Chou C. The utility of a high-throughput scanning biosensor in the detection of the pancreatic cancer marker ULBP2. Biosens Bioelectron 2013; 41:232-7. [DOI: 10.1016/j.bios.2012.08.026] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2012] [Revised: 08/07/2012] [Accepted: 08/10/2012] [Indexed: 11/27/2022]
|
37
|
Cheng MS, Toh CS. Novel biosensing methodologies for ultrasensitive detection of viruses. Analyst 2013; 138:6219-29. [DOI: 10.1039/c3an01394d] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
38
|
Wang XD, Wolfbeis OS. Fiber-Optic Chemical Sensors and Biosensors (2008–2012). Anal Chem 2012; 85:487-508. [DOI: 10.1021/ac303159b] [Citation(s) in RCA: 391] [Impact Index Per Article: 32.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Xu-Dong Wang
- Institute of Analytical Chemistry, Chemo-
and Biosensors, University of Regensburg, D-93040 Regensburg, Germany
| | - Otto S. Wolfbeis
- Institute of Analytical Chemistry, Chemo-
and Biosensors, University of Regensburg, D-93040 Regensburg, Germany
| |
Collapse
|
39
|
Farahi RH, Passian A, Tetard L, Thundat T. Critical issues in sensor science to aid food and water safety. ACS NANO 2012; 6:4548-4556. [PMID: 22564109 DOI: 10.1021/nn204999j] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
The stability of food and water supplies is widely recognized as a global issue of fundamental importance. Sensor development for food and water safety by nonconventional assays continues to overcome technological challenges. The delicate balance between attaining adequate limits of detection, chemical fingerprinting of the target species, dealing with the complex food matrix, and operating in difficult environments are still the focus of current efforts. While the traditional pursuit of robust recognition methods remains important, emerging engineered nanomaterials and nanotechnology promise better sensor performance but also bring about new challenges. Both advanced receptor-based sensors and emerging non-receptor-based physical sensors are evaluated for their critical challenges toward out-of-laboratory applications.
Collapse
Affiliation(s)
- R H Farahi
- Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6123, USA
| | | | | | | |
Collapse
|
40
|
Saha K, Agasti SS, Kim C, Li X, Rotello VM. Gold nanoparticles in chemical and biological sensing. Chem Rev 2012; 112:2739-79. [PMID: 22295941 PMCID: PMC4102386 DOI: 10.1021/cr2001178] [Citation(s) in RCA: 2777] [Impact Index Per Article: 231.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Krishnendu Saha
- Department of Chemistry, University of Massachusetts Amherst, 710 North Pleasant Street, Amherst, MA 01003, USA
| | - Sarit S. Agasti
- Department of Chemistry, University of Massachusetts Amherst, 710 North Pleasant Street, Amherst, MA 01003, USA
| | - Chaekyu Kim
- Department of Chemistry, University of Massachusetts Amherst, 710 North Pleasant Street, Amherst, MA 01003, USA
| | - Xiaoning Li
- Department of Chemistry, University of Massachusetts Amherst, 710 North Pleasant Street, Amherst, MA 01003, USA
| | - Vincent M. Rotello
- Department of Chemistry, University of Massachusetts Amherst, 710 North Pleasant Street, Amherst, MA 01003, USA
| |
Collapse
|
41
|
Jin LH, Li SM, Cho YH. Enhanced detection sensitivity of pegylated CdSe/ZnS quantum dots-based prostate cancer biomarkers by surface plasmon-coupled emission. Biosens Bioelectron 2012; 33:284-7. [PMID: 22310156 DOI: 10.1016/j.bios.2011.12.043] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2011] [Revised: 12/23/2011] [Accepted: 12/25/2011] [Indexed: 11/29/2022]
Abstract
We demonstrate the fabrication and detection of quantum dots (QDs)-based prostate specific antigens (PSAs) cancer protein biochips by using enhanced surface plasmon-coupled emission measurements (SPCE). The PSAs are immobilized on a SiO(2)-protected thin gold substrate and pegylated QDs which conjugated with antibodies of PSA are used as fluorescent probes. Due to the excellent brightness of the QDs and the high directionality of emission, as well as the high light collection efficiency of SPCE, the limit of detection (LOD) is down to 10 fg/mL (equal to 0.3 fM) for the PSA chips by using QDs-based cancer protein. We expect that this QDs-based SPCE measurement system with the low LOD supplies a great potential for detecting various cancer biomarkers that are present in only low concentrations within the human body.
Collapse
Affiliation(s)
- Li-Hua Jin
- Department of Physics and Graduate School of Nanoscience and Technology (WCU), Korea Advanced Institute of Science and Technology, Daejeon 305-701, Republic of Korea
| | | | | |
Collapse
|
42
|
Chang YF, Hung SH, Lee YJ, Chen RC, Su LC, Lai CS, Chou C. Discrimination of Breast Cancer by Measuring Prostate-Specific Antigen Levels in Women's Serum. Anal Chem 2011; 83:5324-8. [DOI: 10.1021/ac200754x] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
| | | | | | | | - Li-Chen Su
- Department of Optics and Photonics, National Central University, Taoyuan 320, Taiwan
| | | | - Chien Chou
- Department of Optics and Photonics, National Central University, Taoyuan 320, Taiwan
| |
Collapse
|