• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4604061)   Today's Articles (1841)   Subscriber (49370)
For: Chawla S, Pundir CS. An electrochemical biosensor for fructosyl valine for glycosylated hemoglobin detection based on core–shell magnetic bionanoparticles modified gold electrode. Biosens Bioelectron 2011;26:3438-43. [DOI: 10.1016/j.bios.2011.01.021] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2010] [Accepted: 01/14/2011] [Indexed: 10/18/2022]
Number Cited by Other Article(s)
1
Salomón-Flores MK, Valdes-García J, Viviano-Posadas AO, Martínez-Otero D, Barroso-Flores J, Bazany-Rodríguez IJ, Dorazco-González A. Molecular two-point recognition of fructosyl valine and fructosyl glycyl histidine in water by fluorescent Zn(II)-terpyridine complexes bearing boronic acids. Dalton Trans 2024;53:8692-8708. [PMID: 38700377 DOI: 10.1039/d4dt00260a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
2
Su Y, Xia C, Zhang H, Gan W, Zhang GQ, Yang Z, Li D. Emerging biosensor probes for glycated hemoglobin (HbA1c) detection. Mikrochim Acta 2024;191:300. [PMID: 38709399 DOI: 10.1007/s00604-024-06380-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 04/22/2024] [Indexed: 05/07/2024]
3
Wang M, Jin L, Hang-Mei Leung P, Wang-Ngai Chow F, Zhao X, Chen H, Pan W, Liu H, Li S. Advancements in magnetic nanoparticle-based biosensors for point-of-care testing. Front Bioeng Biotechnol 2024;12:1393789. [PMID: 38725992 PMCID: PMC11079239 DOI: 10.3389/fbioe.2024.1393789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 04/09/2024] [Indexed: 05/12/2024]  Open
4
Bilge S, Dogan-Topal B, Gürbüz MM, Ozkan SA, Sınağ A. Recent trends in core/shell nanoparticles: their enzyme-based electrochemical biosensor applications. Mikrochim Acta 2024;191:240. [PMID: 38573400 PMCID: PMC10994877 DOI: 10.1007/s00604-024-06305-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Accepted: 03/09/2024] [Indexed: 04/05/2024]
5
Ray A, Atal S, Sharma S, Sampath A. Comparison of Glycated Hemoglobin (HbA1c) Values Estimated by High-Performance Liquid Chromatography and Spectrophotometry: A Pilot Study. Cureus 2024;16:e56964. [PMID: 38665712 PMCID: PMC11044070 DOI: 10.7759/cureus.56964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/25/2024] [Indexed: 04/28/2024]  Open
6
Sriondee Y, Vijitvarasan P, Rattanachata A, Nakajima H, Oaew S, Cheunkar S. Real-time kinetic analysis and detection of glycated hemoglobin A1c using a quartz crystal microbalance-based aptasensor. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024;16:599-607. [PMID: 38197200 DOI: 10.1039/d3ay01842c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2024]
7
Imanzadeh H, Sefid-Sefidehkhan Y, Afshary H, Afruz A, Amiri M. Nanomaterial-based electrochemical sensors for detection of amino acids. J Pharm Biomed Anal 2023;230:115390. [PMID: 37079932 DOI: 10.1016/j.jpba.2023.115390] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 03/24/2023] [Accepted: 04/08/2023] [Indexed: 04/22/2023]
8
Mandali PK, Prabakaran A, Annadurai K, Krishnan UM. Trends in Quantification of HbA1c Using Electrochemical and Point-of-Care Analyzers. SENSORS (BASEL, SWITZERLAND) 2023;23:1901. [PMID: 36850502 PMCID: PMC9965793 DOI: 10.3390/s23041901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2023] [Revised: 01/30/2023] [Accepted: 02/03/2023] [Indexed: 06/18/2023]
9
Zhan Z, Li Y, Zhao Y, Zhang H, Wang Z, Fu B, Li WJ. A Review of Electrochemical Sensors for the Detection of Glycated Hemoglobin. BIOSENSORS 2022;12:bios12040221. [PMID: 35448281 PMCID: PMC9024622 DOI: 10.3390/bios12040221] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 03/29/2022] [Accepted: 03/29/2022] [Indexed: 05/17/2023]
10
Proximity hybridization-induced competitive rolling circle amplification to construct fluorescent dual-sensor for simultaneous evaluation of glycated and total hemoglobin. Biosens Bioelectron 2022;202:113998. [DOI: 10.1016/j.bios.2022.113998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 12/27/2021] [Accepted: 01/11/2022] [Indexed: 11/18/2022]
11
Development of glycated peptide enzyme sensor based flow injection analysis system for haemoglobin A1c monitoring using quasi-direct electron transfer type engineered fructosyl peptide oxidase. Biosens Bioelectron 2021;177:112984. [PMID: 33477030 DOI: 10.1016/j.bios.2021.112984] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 12/26/2020] [Accepted: 01/05/2021] [Indexed: 11/21/2022]
12
Fang F, Li Y, Yang L, Li L, Yan Z, Sun Q. Sensitive and In Situ Hemoglobin Detection Based on a Graphene Oxide Functionalized Microfiber. NANOMATERIALS 2020;10:nano10122461. [PMID: 33317010 PMCID: PMC7763212 DOI: 10.3390/nano10122461] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 12/07/2020] [Accepted: 12/07/2020] [Indexed: 01/22/2023]
13
Shalini Devi K, Sasya M, Krishnan UM. Emerging vistas on electrochemical detection of diabetic retinopathy biomarkers. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115838] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
14
Sharma P, Panchal A, Yadav N, Narang J. Analytical techniques for the detection of glycated haemoglobin underlining the sensors. Int J Biol Macromol 2020;155:685-696. [PMID: 32229211 DOI: 10.1016/j.ijbiomac.2020.03.205] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 03/13/2020] [Accepted: 03/24/2020] [Indexed: 12/24/2022]
15
Shahbazmohammadi H, Sardari S, Omidinia E. An amperometric biosensor for specific detection of glycated hemoglobin based on recombinant engineered fructosyl peptide oxidase. Int J Biol Macromol 2019;142:855-865. [PMID: 31622711 DOI: 10.1016/j.ijbiomac.2019.10.025] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 10/02/2019] [Accepted: 10/02/2019] [Indexed: 11/27/2022]
16
Gold Nanostar Colorimetric Detection of Fructosyl Valine as a Potential Future Point of Care Biosensor Candidate for Glycated Haemoglobin Detection. BIOSENSORS-BASEL 2019;9:bios9030100. [PMID: 31416267 PMCID: PMC6784361 DOI: 10.3390/bios9030100] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 08/02/2019] [Accepted: 08/07/2019] [Indexed: 12/13/2022]
17
Using molecular dynamics simulation to explore the binding of the three potent anticancer drugs sorafenib, streptozotocin, and sunitinib to functionalized carbon nanotubes. J Mol Model 2019;25:159. [DOI: 10.1007/s00894-019-4024-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2018] [Accepted: 04/02/2019] [Indexed: 01/07/2023]
18
Shi Q, Teng Y, Hu Z, Zhang Y, Liu W. One‐step Electrodeposition of Tris(hydroxymethyl) Aminomethane – Prussian Blue on Screen‐printed electrode for Highly Efficient Detection of Glycosylated Hemoglobin. ELECTROANAL 2018. [DOI: 10.1002/elan.201800644] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
19
Chen KJ, Wang CH, Liao CW, Lee CK. Recombinant fructosyl peptide oxidase preparation and its immobilization on polydopamine coating for colorimetric determination of HbA1c. Int J Biol Macromol 2018;120:325-331. [DOI: 10.1016/j.ijbiomac.2018.08.096] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Revised: 08/02/2018] [Accepted: 08/20/2018] [Indexed: 10/28/2022]
20
Kumar S, Sarita, Nehra M, Dilbaghi N, Tankeshwar K, Kim KH. Recent advances and remaining challenges for polymeric nanocomposites in healthcare applications. Prog Polym Sci 2018. [DOI: 10.1016/j.progpolymsci.2018.03.001] [Citation(s) in RCA: 108] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
21
Arvand M, Sanayeei M, Hemmati S. Label-free electrochemical DNA biosensor for guanine and adenine by ds-DNA/poly(L-cysteine)/Fe3O4 nanoparticles-graphene oxide nanocomposite modified electrode. Biosens Bioelectron 2018;102:70-79. [DOI: 10.1016/j.bios.2017.11.002] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Revised: 10/30/2017] [Accepted: 11/01/2017] [Indexed: 11/16/2022]
22
Current Status of HbA1c Biosensors. SENSORS 2017;17:s17081798. [PMID: 28777351 PMCID: PMC5579747 DOI: 10.3390/s17081798] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2017] [Revised: 07/24/2017] [Accepted: 08/01/2017] [Indexed: 01/08/2023]
23
Hussain KK, Moon JM, Park DS, Shim YB. Electrochemical Detection of Hemoglobin: A Review. ELECTROANAL 2017. [DOI: 10.1002/elan.201700308] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
24
Jain U, Gupta S, Chauhan N. Detection of glycated hemoglobin with voltammetric sensing amplified by 3D-structured nanocomposites. Int J Biol Macromol 2017;101:896-903. [PMID: 28365286 DOI: 10.1016/j.ijbiomac.2017.03.127] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 03/19/2017] [Accepted: 03/22/2017] [Indexed: 10/19/2022]
25
Hatada M, Tsugawa W, Kamio E, Loew N, Klonoff DC, Sode K. Development of a screen-printed carbon electrode based disposable enzyme sensor strip for the measurement of glycated albumin. Biosens Bioelectron 2017;88:167-173. [DOI: 10.1016/j.bios.2016.08.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2016] [Revised: 08/01/2016] [Accepted: 08/02/2016] [Indexed: 12/15/2022]
26
Moon JM, Kim DM, Kim MH, Han JY, Jung DK, Shim YB. A disposable amperometric dual-sensor for the detection of hemoglobin and glycated hemoglobin in a finger prick blood sample. Biosens Bioelectron 2016;91:128-135. [PMID: 28006679 DOI: 10.1016/j.bios.2016.12.038] [Citation(s) in RCA: 52] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2016] [Revised: 12/14/2016] [Accepted: 12/14/2016] [Indexed: 11/25/2022]
27
Jain U, Singh A, Kuchhal NK, Chauhan N. Glycated hemoglobin biosensing integration formed on Au nanoparticle-dotted tubular TiO2 nanoarray. Anal Chim Acta 2016;945:67-74. [PMID: 27968717 DOI: 10.1016/j.aca.2016.09.026] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Revised: 09/18/2016] [Accepted: 09/26/2016] [Indexed: 11/30/2022]
28
Zhao Q, Tang S, Fang C, Tu YF. Titania nanotubes decorated with gold nanoparticles for electrochemiluminescent biosensing of glycosylated hemoglobin. Anal Chim Acta 2016;936:83-90. [DOI: 10.1016/j.aca.2016.07.015] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2016] [Revised: 07/01/2016] [Accepted: 07/11/2016] [Indexed: 01/04/2023]
29
Jain U, Chauhan N. Glycated hemoglobin detection with electrochemical sensing amplified by gold nanoparticles embedded N-doped graphene nanosheet. Biosens Bioelectron 2016;89:578-584. [PMID: 26897102 DOI: 10.1016/j.bios.2016.02.033] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2015] [Revised: 02/05/2016] [Accepted: 02/11/2016] [Indexed: 10/22/2022]
30
Determination of β-ODAP by various methods with special emphasis on biosensors: A mini-review. Process Biochem 2015. [DOI: 10.1016/j.procbio.2015.09.021] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
31
Glycated hemoglobin-detection methods based on electrochemical biosensors. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.03.019] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
32
MgO nanobelt-modified graphene-tantalum wire electrode for the simultaneous determination of ascorbic acid, dopamine and uric acid. Electrochim Acta 2015. [DOI: 10.1016/j.electacta.2015.03.215] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
33
Wang B, Anzai JI. Recent Progress in Electrochemical HbA1c Sensors: A Review. MATERIALS (BASEL, SWITZERLAND) 2015;8:1187-1203. [PMID: 28787996 PMCID: PMC5455452 DOI: 10.3390/ma8031187] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2015] [Revised: 03/04/2015] [Accepted: 03/04/2015] [Indexed: 11/18/2022]
34
Using poly(3-aminophenylboronic acid) thin film with binding-induced ion flux blocking for amperometric detection of hemoglobin A1c. Biosens Bioelectron 2015;63:317-324. [DOI: 10.1016/j.bios.2014.07.058] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2014] [Revised: 07/15/2014] [Accepted: 07/16/2014] [Indexed: 11/22/2022]
35
Metal Oxide Nanoparticle-Embedded Chitosan Matrix Based Electrochemical Detection of DNA Hybridization. BIONANOSCIENCE 2014. [DOI: 10.1007/s12668-014-0154-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
36
Electrochemical biosensors based on ferroceneboronic Acid and its derivatives: a review. BIOSENSORS-BASEL 2014;4:243-56. [PMID: 25587421 PMCID: PMC4264357 DOI: 10.3390/bios4030243] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 07/03/2014] [Accepted: 07/25/2014] [Indexed: 11/16/2022]
37
Chauhan N, Pundir CS. Amperometric determination of acetylcholine-A neurotransmitter, by chitosan/gold-coated ferric oxide nanoparticles modified gold electrode. Biosens Bioelectron 2014;61:1-8. [PMID: 24836212 DOI: 10.1016/j.bios.2014.04.048] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2013] [Revised: 04/10/2014] [Accepted: 04/23/2014] [Indexed: 10/25/2022]
38
Determination of glycated hemoglobin with special emphasis on biosensing methods. Anal Biochem 2014;444:47-56. [DOI: 10.1016/j.ab.2013.09.023] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2013] [Revised: 09/21/2013] [Accepted: 09/23/2013] [Indexed: 11/21/2022]
39
Pundir C, Yadav S, Kumar A. Creatinine sensors. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2013.04.013] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
40
Enzymatic biosensors based on the use of metal oxide nanoparticles. Mikrochim Acta 2013. [DOI: 10.1007/s00604-013-1069-5] [Citation(s) in RCA: 96] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
41
Bhatnagar D, Tuteja SK, Rastogi R, Bharadwaj LM. Label-Free Detection of Hemoglobin Using MWNT-Embedded Screen-Printed Electrode. BIONANOSCIENCE 2013. [DOI: 10.1007/s12668-013-0095-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
42
Mallya M, Shenoy R, Kodyalamoole G, Biswas M, Karumathil J, Kamath S. Absorption spectroscopy for the estimation of glycated hemoglobin (HbA1c) for the diagnosis and management of diabetes mellitus: a pilot study. Photomed Laser Surg 2013;31:219-24. [PMID: 23597421 DOI: 10.1089/pho.2012.3421] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]  Open
43
Devi R, Yadav S, Nehra R, Yadav S, Pundir C. Electrochemical biosensor based on gold coated iron nanoparticles/chitosan composite bound xanthine oxidase for detection of xanthine in fish meat. J FOOD ENG 2013. [DOI: 10.1016/j.jfoodeng.2012.10.014] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
44
Netto CG, Toma HE, Andrade LH. Superparamagnetic nanoparticles as versatile carriers and supporting materials for enzymes. ACTA ACUST UNITED AC 2013. [DOI: 10.1016/j.molcatb.2012.08.010] [Citation(s) in RCA: 177] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
45
An amperometric glutathione biosensor based on chitosan–iron coated gold nanoparticles modified Pt electrode. Int J Biol Macromol 2012;51:879-86. [DOI: 10.1016/j.ijbiomac.2012.08.008] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2012] [Accepted: 08/08/2012] [Indexed: 11/22/2022]
46
Xu Y, Wang E. Electrochemical biosensors based on magnetic micro/nano particles. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2012.03.147] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
47
Poiata A, Creanga DE, Nadejde C, Fifere N, Airinei A. Chemically modified nanoparticles surface for sensing bacterial loading--experimental study based on fluorescence stimulation by iron ions. Bioelectrochemistry 2012. [PMID: 23186558 DOI: 10.1016/j.bioelechem.2012.10.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
48
Chawla S, Pundir CS. An amperometric hemoglobin A1c biosensor based on immobilization of fructosyl amino acid oxidase onto zinc oxide nanoparticles–polypyrrole film. Anal Biochem 2012;430:156-62. [DOI: 10.1016/j.ab.2012.08.002] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2012] [Revised: 07/25/2012] [Accepted: 08/03/2012] [Indexed: 10/28/2022]
49
Traore ZS, Shah SM, Su X. Flow-injection chemiluminescence determination of haemoglobin in the blood. LUMINESCENCE 2012;28:56-62. [DOI: 10.1002/bio.2337] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2011] [Revised: 12/09/2011] [Accepted: 12/10/2011] [Indexed: 11/08/2022]
50
Interaction of valine and valine radicals with single-walled carbon nanotube (5,0). Chem Phys Lett 2011. [DOI: 10.1016/j.cplett.2011.06.032] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA