1
|
Electric Cell-Substrate Impedance Sensing (ECIS) as a Convenient Tool to Assess the Potential of Low Molecular Fraction Derived from Medicinal Fungus Cerrena unicolor in Action on L929 and CT-26 Cell Lines. Molecules 2022; 27:molecules27196251. [PMID: 36234787 PMCID: PMC9571975 DOI: 10.3390/molecules27196251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 09/09/2022] [Accepted: 09/19/2022] [Indexed: 11/17/2022] Open
Abstract
The increase in the incidence of cancer has contributed to the search for new therapeutic methods. In recent years, the use of preparations of natural origin from medical fungi has increased. One such active substance is the extracellular, low molecular active fraction obtained from the medicinal fungus Cerrena unicolor. This study aimed to monitor the pharmacokinetics of different concentrations of substances isolated from the medicinal fungus Cerrena unicolor (ex-LMS) using the ECIS technique. In the study, mouse L929 fibroblasts and colon cancer CT26 cell lines were treated with different concentrations of the active fractions obtained from Cerrena unicolor: C1 = 2.285 (μg/mL); C2 = 22.85 (μg/mL); and C3 = 228.5 (μg/mL). This study demonstrated that the tested preparation from Cerrena unicolor had no considerable effect on the resistance, capacitance, and impedance of L929 fibroblast cells, which was an indicator of no significant effect on its physiological processes. At the same time, those parameters exhibited a decrease in colon cancer cell viability. Following our previous and current studies on Cerrena unicolor, ex-LMS extracts can be safely used in anticancer therapy or chemoprevention with no significant harmful effects on normal cells.
Collapse
|
2
|
Böttcher B, Pflieger A, Schumacher J, Jungnickel B, Feller KH. 3D Bioprinting of Prevascularized Full-Thickness Gelatin-Alginate Structures with Embedded Co-Cultures. Bioengineering (Basel) 2022; 9:bioengineering9060242. [PMID: 35735485 PMCID: PMC9219913 DOI: 10.3390/bioengineering9060242] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 05/15/2022] [Accepted: 05/16/2022] [Indexed: 12/24/2022] Open
Abstract
The use of bioprinting allows the creation of complex three-dimensional cell laden grafts with spatial placements of different cell lines. However, a major challenge is insufficient nutrient transfer, especially with the increased size of the graft causing necrosis and reduced proliferation. A possibility to improve nutrient support is the integration of tubular structures for reducing diffusion paths. In this study the influence of prevascularization in full-thickness grafts on cell growth with a variation of cultivation style and cellular composition was investigated. To perform this, the rheological properties of the used gelatin-alginate hydrogel as well as possibilities to improve growth conditions in the hydrogel were assessed. Prevascularized grafts were manufactured using a pneumatic extrusion-based bioprinter with a coaxial extrusion tool. The prevascularized grafts were statically and dynamically cultured with a monoculture of HepG2 cells. Additionally, a co-culture of HepG2 cells, fibroblasts and HUVEC-TERT2 was created while HUVEC-TERT2s were concentrically placed around the hollow channels. A static culture of prevascularized grafts showed short-term improvements in cell proliferation compared to avascular grafts, while a perfusion-based culture showed improvements in mid-term cultivation times. The cultivation of the co-culture indicated the formation of vascular structures from the hollow channels toward avascular areas. According to these results, the integration of prevascular structures show beneficial effects for the in vitro cultivation of bioprinted grafts for which its impact can be increased in larger grafts.
Collapse
Affiliation(s)
- Bastian Böttcher
- Institute for Microsystem and Precision Engineering, Ernst-Abbe University of Applied Science Jena, 07745 Jena, Germany; (B.B.); (A.P.); (J.S.)
| | - Astrid Pflieger
- Institute for Microsystem and Precision Engineering, Ernst-Abbe University of Applied Science Jena, 07745 Jena, Germany; (B.B.); (A.P.); (J.S.)
| | - Jan Schumacher
- Institute for Microsystem and Precision Engineering, Ernst-Abbe University of Applied Science Jena, 07745 Jena, Germany; (B.B.); (A.P.); (J.S.)
| | - Berit Jungnickel
- Department of Cell Biology, Institute of Biochemistry and Biophysics, Faculty of Biological Sciences, Friedrich Schiller University Jena, 07745 Jena, Germany;
| | - Karl-Heinz Feller
- Institute for Microsystem and Precision Engineering, Ernst-Abbe University of Applied Science Jena, 07745 Jena, Germany; (B.B.); (A.P.); (J.S.)
- Correspondence: ; Tel.: +49-3641-205-621
| |
Collapse
|
3
|
Taghavizadeh Yazdi ME, Amiri MS, Nourbakhsh F, Rahnama M, Forouzanfar F, Mousavi SH. Bio-indicators in cadmium toxicity: Role of HSP27 and HSP70. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:26359-26379. [PMID: 33834331 DOI: 10.1007/s11356-021-13687-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Accepted: 03/24/2021] [Indexed: 06/12/2023]
Abstract
Heat shock proteins (HSPs) are a family of proteins that are expressed by cells in reply to stressors. The changes in concentration of HSPs could be utilized as a bio-indicator of oxidative stress caused by heavy metal. Exposure to the different heavy metals may induce or reduce the expression of different HSPs. The exposure to cadmium ion (Cd2+) could increase HSP70 and HSP27 over 2- to 10-fold or even more. The in vitro and in vivo models indicate that the HSP70 family is more sensitive to Cd intoxication than other HSPs. The analyses of other HSPs along with HSP70, especially HSP27, could also be useful to obtain more accurate results. In this regard, this review focuses on examining the literature to bold the futuristic uses of HSPs as bio-indicators in the initial assessment of Cd exposure risks in defined environments.
Collapse
Affiliation(s)
| | | | - Fahimeh Nourbakhsh
- Medical Toxicology Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mostafa Rahnama
- Department of Plant Pathology, University of Kentucky, Lexington, KY, 40506, USA
| | - Fatemeh Forouzanfar
- Neuroscience Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Neuroscience, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Seyed Hadi Mousavi
- Medical Toxicology Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
- Department of Pharmacology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
4
|
Iwakura T, Marschner JA, Zhao ZB, Świderska MK, Anders HJ. Electric cell-substrate impedance sensing in kidney research. Nephrol Dial Transplant 2021; 36:216-223. [PMID: 31598727 DOI: 10.1093/ndt/gfz191] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2019] [Accepted: 08/18/2019] [Indexed: 12/20/2022] Open
Abstract
Electric cell-substrate impedance sensing (ECIS) is a quantitative, label-free, non-invasive analytical method allowing continuous monitoring of the behaviour of adherent cells by online recording of transcellular impedance. ECIS offers a wide range of practical applications to study cell proliferation, migration, differentiation, toxicity and monolayer barrier integrity. All of these applications are relevant for basic kidney research, e.g. on endothelial cells, tubular and glomerular epithelial cells. This review gives an overview on the fundamental principles of the ECIS technology. We name strengths and remaining hurdles for practical applications, present an ECIS array reuse protocol, and review its past, present and potential future contributions to preclinical kidney research.
Collapse
Affiliation(s)
- Takamasa Iwakura
- Renal Division, Medizinische Klinik und Poliklinik IV, Klinikum der Universität München, LMU Munich, München, Germany.,Internal Medicine I, Division of Nephrology, Hamamatsu University School of Medicine, Hamamatsu, Japan
| | - Julian A Marschner
- Renal Division, Medizinische Klinik und Poliklinik IV, Klinikum der Universität München, LMU Munich, München, Germany
| | - Zhi Bo Zhao
- Renal Division, Medizinische Klinik und Poliklinik IV, Klinikum der Universität München, LMU Munich, München, Germany
| | - Monika Katarzyna Świderska
- Renal Division, Medizinische Klinik und Poliklinik IV, Klinikum der Universität München, LMU Munich, München, Germany
| | - Hans-Joachim Anders
- Renal Division, Medizinische Klinik und Poliklinik IV, Klinikum der Universität München, LMU Munich, München, Germany
| |
Collapse
|
5
|
Wagner GK, Jaszek M, Staniec B, Prendecka M, Pigoń D, Belcarz A, Stefaniuk D, Matuszewska A, Pietrykowska-Tudruj E, Zagaja M. Lasius fuliginosus Nest Carton as a Source of New Promising Bioactive Extracts with Chemopreventive Potential. Int J Mol Sci 2021; 22:ijms22094392. [PMID: 33922345 PMCID: PMC8122773 DOI: 10.3390/ijms22094392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 04/20/2021] [Accepted: 04/20/2021] [Indexed: 11/16/2022] Open
Abstract
Six new water extracts (E1-E6) were obtained from nest carton produced by jet black ants Lasius fuliginosus and tested for their biochemical and bioactive properties, including antioxidative and anticancer effects. The present study demonstrated significant qualitative and quantitative differences in the content of individual biochemical constituents, as well as bioactive properties between the investigated samples. All tested extracts demonstrated antioxidant properties (determined using 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid (ABTS) methods), and the highest antioxidative potential was recorded in extracts E1 and E2 (188.96 and 313.67 μg/mL of ascorbic acid equivalent for ABTS and 176.42 and 202.66 μg/mL for DPPH reagent). Furthermore the six extracts exhibited strong inhibitory activity towards human melanoma cells of the A-375 CRL-1619 line in a dose-dependent manner. The most interesting chemopreventive activity was exhibited by extract E2, which inhibited the proliferation of A-375 cells to the greatest extent, while having a minimal effect on Vero cells. The effect on cancer cells has been confirmed using the Electric Cell-substrate Impedance Sensing (ECIS) technique. Significant impedance changes have been detected in A-375 and Vero cells following the administration of extract E2. The obtained results are really promising and constitute the basis for further research on the nest carton of jet black ant.
Collapse
Affiliation(s)
- Grzegorz Karol Wagner
- Department of Zoology and Nature Protection, Institute of Biological Sciences, Maria Curie-Skłodowska University, Akademicka 19, 20-033 Lublin, Poland; (B.S.); (E.P.-T.)
- Correspondence: (G.K.W.); (M.J.)
| | - Magdalena Jaszek
- Department of Biochemistry and Biotechnology, Institute of Biological Sciences, Maria Curie-Skłodowska University, Akademicka 19, 20-033 Lublin, Poland; (D.S.); (A.M.)
- Correspondence: (G.K.W.); (M.J.)
| | - Bernard Staniec
- Department of Zoology and Nature Protection, Institute of Biological Sciences, Maria Curie-Skłodowska University, Akademicka 19, 20-033 Lublin, Poland; (B.S.); (E.P.-T.)
| | - Monika Prendecka
- Chair and Department of Human Physiology, Medical University of Lublin, Radziwiłłowska 11, 20-080 Lublin, Poland; (M.P.); (D.P.)
| | - Dominika Pigoń
- Chair and Department of Human Physiology, Medical University of Lublin, Radziwiłłowska 11, 20-080 Lublin, Poland; (M.P.); (D.P.)
| | - Anna Belcarz
- Chair and Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodźki 1, 20-093 Lublin, Poland;
| | - Dawid Stefaniuk
- Department of Biochemistry and Biotechnology, Institute of Biological Sciences, Maria Curie-Skłodowska University, Akademicka 19, 20-033 Lublin, Poland; (D.S.); (A.M.)
| | - Anna Matuszewska
- Department of Biochemistry and Biotechnology, Institute of Biological Sciences, Maria Curie-Skłodowska University, Akademicka 19, 20-033 Lublin, Poland; (D.S.); (A.M.)
| | - Ewa Pietrykowska-Tudruj
- Department of Zoology and Nature Protection, Institute of Biological Sciences, Maria Curie-Skłodowska University, Akademicka 19, 20-033 Lublin, Poland; (B.S.); (E.P.-T.)
| | - Mirosław Zagaja
- Isobolographic Analysis Laboratory, Institute of Rural Health, Jaczewskiego 2, 20-090 Lublin, Poland;
| |
Collapse
|
6
|
Gheorghiu M. A short review on cell-based biosensing: challenges and breakthroughs in biomedical analysis. J Biomed Res 2020; 35:255-263. [PMID: 33888671 PMCID: PMC8383170 DOI: 10.7555/jbr.34.20200128] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 10/13/2020] [Accepted: 11/06/2020] [Indexed: 12/14/2022] Open
Abstract
Current cell-based biosensors have progressed substantially from mere alternatives to molecular bioreceptors into enabling tools for interfacing molecular machineries and gene circuits with microelectronics and for developing groundbreaking sensing and theragnostic platforms. The recent literature concerning whole-cell biosensors is reviewed with an emphasis on mammalian cells, and the challenges and breakthroughs brought along in biomedical analyses through novel biosensing concepts and the synthetic biology toolbox. These recent innovations allow development of cell-based biosensing platforms having tailored performances and capable to reach the levels of sensitivity, dynamic range, and stability suitable for high analytic/medical relevance. They also pave the way for the construction of flexible biosensing platforms with utility across biological research and clinical applications. The work is intended to stimulate interest in generation of cell-based biosensors and improve their acceptance and exploitation.
Collapse
Affiliation(s)
- Mihaela Gheorghiu
- Biosensors Department, International Centre of Biodynamics, Bucharest 060101, Romania
| |
Collapse
|
7
|
Gheorghiu M, Stănică L, Ghinia Tegla MG, Polonschii C, Bratu D, Popescu O, Badea T, Gheorghiu E. Cellular sensing platform with enhanced sensitivity based on optogenetic modulation of cell homeostasis. Biosens Bioelectron 2020; 154:112003. [PMID: 32056953 PMCID: PMC7685521 DOI: 10.1016/j.bios.2019.112003] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 12/26/2019] [Accepted: 12/28/2019] [Indexed: 12/29/2022]
Abstract
We demonstrate a new biosensing concept with impact on the development of rapid, point of need cell based sensing with boosted sensitivity and wide relevance for bioanalysis. It involves optogenetic stimulation of cells stably transfected to express light sensitive protein channels for optical control of membrane potential and of ion homeostasis. Time-lapse impedance measurements are used to reveal cell dynamics changes encompassing cellular responses to bioactive stimuli and optically induced homeostasis disturbances. We prove that light driven perturbations of cell membrane potential induce homeostatic reactions and modulate transduction mechanisms that amplify cellular response to bioactive compounds. This allows cell based biosensors to respond more rapidly and sensitively to low concentrations of bioactive/toxic analytes: statistically relevant impedance changes are recorded in less than 30 min, in comparison with >8 h in the best alternative reported tests for the same low concentration (e.g. a concentration of 25 μM CdCl2, lower than the threshold concentration in classical cellular sensors). Comparative analysis of model bioactive/toxic compounds (ouabain and CdCl2) demonstrates that cellular reactivity can be boosted by light driven perturbations of cellular homeostasis and that this biosensing concept is able to discriminate analytes with different modes of action (i.e. CdCl2 toxicity versus ion pump inhibition by ouabain), a significant advance against state of the art cell based sensors.
Collapse
Affiliation(s)
- Mihaela Gheorghiu
- International Centre of Biodynamics, Intr. Portocalelor 1 B, 060101, Bucharest, Romania; Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, Bucharest, 050095, Romania.
| | - Luciana Stănică
- International Centre of Biodynamics, Intr. Portocalelor 1 B, 060101, Bucharest, Romania; Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, Bucharest, 050095, Romania
| | - Miruna G Ghinia Tegla
- Institute for Interdisciplinary Research in Bio-Nano-Sciences, Molecular Biology Center, Babes-Bolyai-University, 400084, Cluj-Napoca, Romania; Retinal Circuit Development & Genetics Unit N-NRL/NEI/NIH 6 Center Drive Bethesda, 20892, Maryland, United States
| | - Cristina Polonschii
- International Centre of Biodynamics, Intr. Portocalelor 1 B, 060101, Bucharest, Romania.
| | - Dumitru Bratu
- International Centre of Biodynamics, Intr. Portocalelor 1 B, 060101, Bucharest, Romania.
| | - Octavian Popescu
- Institute for Interdisciplinary Research in Bio-Nano-Sciences, Molecular Biology Center, Babes-Bolyai-University, 400084, Cluj-Napoca, Romania; Institute of Biology, Romanian Academy, 296 Splaiul Independentei, 060031, Bucharest, Romania
| | - Tudor Badea
- Retinal Circuit Development & Genetics Unit N-NRL/NEI/NIH 6 Center Drive Bethesda, 20892, Maryland, United States.
| | - Eugen Gheorghiu
- International Centre of Biodynamics, Intr. Portocalelor 1 B, 060101, Bucharest, Romania; Faculty of Biology, University of Bucharest, 91-95 Splaiul Independentei, Bucharest, 050095, Romania.
| |
Collapse
|
8
|
Gheorghiu M, Stanica L, Polonschii C, David S, Ruckenstein A, Popescu O, Badea T, Gheorghiu E. Modulation of Cellular Reactivity for Enhanced Cell-Based Biosensing. Anal Chem 2019; 92:806-814. [PMID: 31751507 DOI: 10.1021/acs.analchem.9b03217] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Cell-based sensing platforms provide functional information on cellular effects of bioactive or toxic compounds in a sample. Current challenges concern the rather extended length of the assays as well as their limited reproducibility and sensitivity. We present a biosensing method capable of appraising, on a short time scale and with exquisite sensitivity, the occurrence and the magnitude of cellular alterations induced by low levels of a bioactive/toxic compound. Our method is based on integrating optogenetic control of non-electrogenic human cells, modified to express light sensitive protein channels, into a non-invasive electro-optical analytical platform enabling quantitative assessment of the stimulus dependent, dynamical cellular response. Our system exploits the interplay between optogenetic stimulation and time lapse fast impedance assays in boosting the platform sensitivity when exposing cells to a model exogenous stimulus, under both static and flow conditions. The proposed optogenetically modulated cell-based sensing platform is suitable for in field applications and provides a new paradigm for impedance-based sensing.
Collapse
Affiliation(s)
- Mihaela Gheorghiu
- International Centre of Biodynamics , Intrarea Portocalelor 1 B , 060101 Bucharest , Romania.,Faculty of Biology , University of Bucharest , 91-95 Splaiul Independentei , Bucharest 050095 , Romania
| | - Luciana Stanica
- International Centre of Biodynamics , Intrarea Portocalelor 1 B , 060101 Bucharest , Romania.,Faculty of Biology , University of Bucharest , 91-95 Splaiul Independentei , Bucharest 050095 , Romania
| | - Cristina Polonschii
- International Centre of Biodynamics , Intrarea Portocalelor 1 B , 060101 Bucharest , Romania
| | - Sorin David
- International Centre of Biodynamics , Intrarea Portocalelor 1 B , 060101 Bucharest , Romania
| | - Andrei Ruckenstein
- Department of Physics , Boston University , 590 Commonwealth Avenue , Boston , Massachusetts 02215 , United States
| | - Octavian Popescu
- Institute for Interdisciplinary Research in Bio-Nano-Sciences, Molecular Biology Center , Babes-Bolyai-University , 400084 Cluj-Napoca , Romania.,Institute of Biology Bucharest , Romanian Academy , 296 Splaiul Independentei , 060031 Bucharest , Romania
| | - Tudor Badea
- Retinal Circuit Development & Genetics Unit , Neurobiology Neurodegeneration & Repair Laboratory, National Eye Institute of the National Institutes of Health (N-NRL/NEI/NIH) , 6 Center Drive , Bethesda 20892 , Maryland , United States
| | - Eugen Gheorghiu
- International Centre of Biodynamics , Intrarea Portocalelor 1 B , 060101 Bucharest , Romania.,Faculty of Biology , University of Bucharest , 91-95 Splaiul Independentei , Bucharest 050095 , Romania
| |
Collapse
|
9
|
Dubiak-Szepietowska M, Karczmarczyk A, Winckler T, Feller KH. A cell-based biosensor for nanomaterials cytotoxicity assessment in three dimensional cell culture. Toxicology 2016; 370:60-69. [PMID: 27693313 DOI: 10.1016/j.tox.2016.09.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Revised: 09/22/2016] [Accepted: 09/26/2016] [Indexed: 12/17/2022]
Abstract
Nanoparticles (NPs) are widely used in consumer and medicinal products. The high prevalence of nanoparticles in the environment raises concerns regarding their effects on human health, but there is limited knowledge about how NPs interact with cells or tissues. Because the European Union has called for a substantial reduction of animal experiments for scientific purposes (Directive 2010/63), increased efforts are required to develop in vitro models to evaluate potentially hazardous agents. Here, we describe a new cell-based biosensor for the evaluation of NPs cytotoxicity. The new biosensor is based on transgenic human hepatoblastoma cells (HepG2) that express a secreted form of alkaline phosphatase (SEAP) as a reporter protein whose expression is induced upon activation of a stress response pathway controlled by the transcription regulator nuclear factor-κB (NF-κB). The NF-κB_HepG2 sensor cells were cultured in a Matrigel-based three dimensional environment to simulate the in vivo situation. The new biosensor cells offer the advantage of generating fast and reproducible readout at lower concentrations and shorter incubation time than conventional viability assays, avoid possible interaction between nanomaterials and assay compounds, therefore, minimize generation of false positive or negative results and indicate mechanism of toxicity through NF-κB signaling.
Collapse
Affiliation(s)
- Monika Dubiak-Szepietowska
- Department of Medical Engineering and Biotechnology, Ernst-Abbe-University of Applied Sciences Jena, Carl-Zeiss Promenade 2, 07745 Jena, Germany.
| | - Aleksandra Karczmarczyk
- Department of Medical Engineering and Biotechnology, Ernst-Abbe-University of Applied Sciences Jena, Carl-Zeiss Promenade 2, 07745 Jena, Germany
| | - Thomas Winckler
- Institute of Pharmacy, Friedrich Schiller University Jena, Semmelweissstrasse 10, 07743 Jena, Germany
| | - Karl-Heinz Feller
- Department of Medical Engineering and Biotechnology, Ernst-Abbe-University of Applied Sciences Jena, Carl-Zeiss Promenade 2, 07745 Jena, Germany
| |
Collapse
|
10
|
Application of 2D Non-Graphene Materials and 2D Oxide Nanostructures for Biosensing Technology. SENSORS 2016; 16:223. [PMID: 26861346 PMCID: PMC4801599 DOI: 10.3390/s16020223] [Citation(s) in RCA: 104] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/01/2016] [Accepted: 02/02/2016] [Indexed: 12/12/2022]
Abstract
The discovery of graphene and its unique properties has inspired researchers to try to invent other two-dimensional (2D) materials. After considerable research effort, a distinct “beyond graphene” domain has been established, comprising the library of non-graphene 2D materials. It is significant that some 2D non-graphene materials possess solid advantages over their predecessor, such as having a direct band gap, and therefore are highly promising for a number of applications. These applications are not limited to nano- and opto-electronics, but have a strong potential in biosensing technologies, as one example. However, since most of the 2D non-graphene materials have been newly discovered, most of the research efforts are concentrated on material synthesis and the investigation of the properties of the material. Applications of 2D non-graphene materials are still at the embryonic stage, and the integration of 2D non-graphene materials into devices is scarcely reported. However, in recent years, numerous reports have blossomed about 2D material-based biosensors, evidencing the growing potential of 2D non-graphene materials for biosensing applications. This review highlights the recent progress in research on the potential of using 2D non-graphene materials and similar oxide nanostructures for different types of biosensors (optical and electrochemical). A wide range of biological targets, such as glucose, dopamine, cortisol, DNA, IgG, bisphenol, ascorbic acid, cytochrome and estradiol, has been reported to be successfully detected by biosensors with transducers made of 2D non-graphene materials.
Collapse
|
11
|
Lafleur JP, Jönsson A, Senkbeil S, Kutter JP. Recent advances in lab-on-a-chip for biosensing applications. Biosens Bioelectron 2016; 76:213-33. [DOI: 10.1016/j.bios.2015.08.003] [Citation(s) in RCA: 126] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2015] [Revised: 07/31/2015] [Accepted: 08/03/2015] [Indexed: 12/15/2022]
|
12
|
Stolwijk JA, Matrougui K, Renken CW, Trebak M. Impedance analysis of GPCR-mediated changes in endothelial barrier function: overview and fundamental considerations for stable and reproducible measurements. Pflugers Arch 2015; 467:2193-218. [PMID: 25537398 PMCID: PMC4480219 DOI: 10.1007/s00424-014-1674-0] [Citation(s) in RCA: 73] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Revised: 12/11/2014] [Accepted: 12/11/2014] [Indexed: 12/19/2022]
Abstract
The past 20 years has seen significant growth in using impedance-based assays to understand the molecular underpinning of endothelial and epithelial barrier function in response to physiological agonists and pharmacological and toxicological compounds. Most studies on barrier function use G protein-coupled receptor (GPCR) agonists which couple to fast and transient changes in barrier properties. The power of impedance-based techniques such as electric cell-substrate impedance sensing (ECIS) resides in its ability to detect minute changes in cell layer integrity label-free and in real-time ranging from seconds to days. We provide a comprehensive overview of the biophysical principles, applications, and recent developments in impedance-based methodologies. Despite extensive application of impedance analysis in endothelial barrier research, little attention has been paid to data analysis and critical experimental variables, which are both essential for signal stability and reproducibility. We describe the rationale behind common ECIS data presentation and interpretation and illustrate practical guidelines to improve signal intensity by adapting technical parameters such as electrode layout, monitoring frequency, or parameter (resistance versus impedance magnitude). Moreover, we discuss the impact of experimental parameters, including cell source, liquid handling, and agonist preparation on signal intensity and kinetics. Our discussions are supported by experimental data obtained from human microvascular endothelial cells challenged with three GPCR agonists, thrombin, histamine, and sphingosine-1-phosphate.
Collapse
Affiliation(s)
- Judith A Stolwijk
- The SUNY College of Nanoscale Science and Engineering (CNSE), SUNY Polytechnic Institute, State University of New York, 257 Fuller Rd., Albany, NY, 12203, USA
- Applied BioPhysics Inc., Troy, NY, USA
| | - Khalid Matrougui
- Department of Physiological Sciences, East Virginia Medical School, Norfolk, VA, USA
| | | | - Mohamed Trebak
- The SUNY College of Nanoscale Science and Engineering (CNSE), SUNY Polytechnic Institute, State University of New York, 257 Fuller Rd., Albany, NY, 12203, USA.
| |
Collapse
|
13
|
Wegener J. Cell-Based Microarrays for In Vitro Toxicology. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2015; 8:335-358. [PMID: 26077916 DOI: 10.1146/annurev-anchem-071213-020051] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
DNA/RNA and protein microarrays have proven their outstanding bioanalytical performance throughout the past decades, given the unprecedented level of parallelization by which molecular recognition assays can be performed and analyzed. Cell microarrays (CMAs) make use of similar construction principles. They are applied to profile a given cell population with respect to the expression of specific molecular markers and also to measure functional cell responses to drugs and chemicals. This review focuses on the use of cell-based microarrays for assessing the cytotoxicity of drugs, toxins, or chemicals in general. It also summarizes CMA construction principles with respect to the cell types that are used for such microarrays, the readout parameters to assess toxicity, and the various formats that have been established and applied. The review ends with a critical comparison of CMAs and well-established microtiter plate (MTP) approaches.
Collapse
Affiliation(s)
- Joachim Wegener
- Institute for Analytical Chemistry, University of Regensburg, D-93053 Regensburg, Germany;
| |
Collapse
|
14
|
Cheng MS, Lau SH, Chan KP, Toh CS, Chow VT. Impedimetric cell-based biosensor for real-time monitoring of cytopathic effects induced by dengue viruses. Biosens Bioelectron 2015; 70:74-80. [PMID: 25794961 PMCID: PMC7126431 DOI: 10.1016/j.bios.2015.03.018] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2014] [Revised: 03/08/2015] [Accepted: 03/09/2015] [Indexed: 02/07/2023]
Abstract
We describe an impedimetric cell-based biosensor constructed from poly-l-lysine (PLL)-modified screen-printed carbon electrode for real-time monitoring of dengue virus (DENV) infection of surface-immobilized baby hamster kidney (BHK-21) fibroblast cells. Cytopathic effects (CPE) induced by DENV-2 New Guinea C strain (including degenerative morphological changes, detachment, membrane degradation and death of host cells), were reflected by drastic decrease in impedance signal response detected as early as ~30 hours post-infection (hpi). In contrast, distinct CPE by conventional microscopy was evident only at ~72 hpi at the corresponding multiplicity of infection (MOI) of 10. A parameter that describes the kinetics of cytopathogenesis, CIT50, which refers to the time taken for 50% reduction in impedance signal response, revealed an inverse linear relationship with virus titer and MOI. CIT50 values were also delayed by 31.5 h for each order of magnitude decrease in MOI. Therefore, based on the analysis of CIT50, the virus titer of a given sample can be determined from the measured impedance signal response. Furthermore, consistent impedance results were also obtained with clinical isolates of the four DENV serotypes verified by RT-PCR and cycle sequencing. This impedimetric cell-based biosensor represents a label-free and continuous approach for the dynamic measurement of cellular responses toward DENV infection, and for detecting the presence of infectious viral particles. Impedimetric cell-based biosensor detected negligible changes in cell morphology and adhesion caused by dengue virus infection. Dengue viral-induced cytopathic effects could be detected within ~30 hours post-infection. Virus titers may be estimated based on impedance signal responses. Advantages include non-invasive label-free measurement, reduced diagnosis time, and identification of infectious viruses. Potentially useful application for the analysis of clinical isolates.
Collapse
Affiliation(s)
- Ming Soon Cheng
- Division of Chemistry and Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371, Singapore
| | - Suk Hiang Lau
- Host and Pathogen Interactivity Laboratory, Department of Microbiology, Yong Loo Lin School of Medicine, 5 Science Drive 2, National University Health System, National University of Singapore, Singapore 117545, Singapore
| | - Kwai Peng Chan
- Virology Section, Department of Pathology, Singapore General Hospital, Outram Road, Singapore 169608, Singapore
| | - Chee-Seng Toh
- Division of Chemistry and Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371, Singapore
| | - Vincent T Chow
- Host and Pathogen Interactivity Laboratory, Department of Microbiology, Yong Loo Lin School of Medicine, 5 Science Drive 2, National University Health System, National University of Singapore, Singapore 117545, Singapore.
| |
Collapse
|
15
|
Özçelik H, Padeste C, Hasirci V. Systematically organized nanopillar arrays reveal differences in adhesion and alignment properties of BMSC and Saos-2 cells. Colloids Surf B Biointerfaces 2014; 119:71-81. [DOI: 10.1016/j.colsurfb.2014.03.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2013] [Revised: 03/06/2014] [Accepted: 03/10/2014] [Indexed: 10/25/2022]
|
16
|
A sensitive sensor cell line for the detection of oxidative stress responses in cultured human keratinocytes. SENSORS 2014; 14:11293-307. [PMID: 24967604 PMCID: PMC4168474 DOI: 10.3390/s140711293] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2014] [Revised: 06/16/2014] [Accepted: 06/18/2014] [Indexed: 11/16/2022]
Abstract
In the progress of allergic and irritant contact dermatitis, chemicals that cause the generation of reactive oxygen species trigger a heat shock response in keratinocytes. In this study, an optical sensor cell line based on cultured human keratinocytes (HaCaT cells) expressing green fluorescent protein (GFP) under the control of the stress-inducible HSP70B' promoter were constructed. Exposure of HaCaT sensor cells to 25 µM cadmium, a model substance for oxidative stress induction, provoked a 1.7-fold increase in total glutathione and a ~300-fold induction of transcript level of the gene coding for heat shock protein HSP70B'. An extract of Arnica montana flowers resulted in a strong induction of the HSP70B' gene and a pronounced decrease of total glutathione in keratinocytes. The HSP70B' promoter-based sensor cells conveniently detected cadmium-induced stress using GFP fluorescence as read-out with a limit of detection of 6 µM cadmium. In addition the sensor cells responded to exposure of cells to A. montana extract with induction of GFP fluorescence. Thus, the HaCaT sensor cells provide a means for the automated detection of the compromised redox status of keratinocytes as an early indicator of the development of human skin disorders and could be applied for the prediction of skin irritation in more complex in vitro 3D human skin models and in the development of micro-total analysis systems (µTAS) that may be utilized in dermatology, toxicology, pharmacology and drug screenings.
Collapse
|
17
|
Kling B, Bücherl D, Palatzky P, Matysik FM, Decker M, Wegener J, Heilmann J. Flavonoids, flavonoid metabolites, and phenolic acids inhibit oxidative stress in the neuronal cell line HT-22 monitored by ECIS and MTT assay: a comparative study. JOURNAL OF NATURAL PRODUCTS 2014; 77:446-454. [PMID: 24245939 DOI: 10.1021/np400518k] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
A real-time and label-free in vitro assay based on electric cell-substrate impedance sensing (ECIS) was established, validated, and compared to an end-point MTT assay within an experimental trial addressing the cytoprotective effects of 19 different flavonoids, flavonoid metabolites, and phenolic acids and their methyl esters on the HT-22 neuronal cell line, after induction of oxidative stress with tert-butyl hydroperoxide. Among the flavonoids under study, only those with a catechol unit and an additional 4-keto group provided cytoprotection. The presence of a 2,3-double bond was not a structural prerequisite for a neuroprotective effect. In the case of the phenolics, catechol substitution was the only structural requirement for activity. The flavonoids and other phenolics with a ferulic acid substitution or a single hydroxy group showed no activity. Electrochemical characterization of all compounds via square-wave voltammetry provided a rather specific correlation between cytoprotective activity and redox potential for the active flavonoids, but not for the active phenolics with a low molecular weight. Moreover this study was used to compare label-free ECIS recordings with results of the established MTT assay. Whereas the former provides time-resolved and thus entirely unbiased information on changes of cell morphology that are unequivocally associated with cell death, the latter requires predefined exposure times and a strict causality between metabolic activity and cell death. However, MTT assays are based on standard lab equipment and provide a more economic way to higher throughput.
Collapse
Affiliation(s)
- Beata Kling
- Institut für Pharmazie, Universität Regensburg , Universitätsstraße 31, 93053 Regensburg, Germany
| | | | | | | | | | | | | |
Collapse
|
18
|
Murugaiyan SB, Ramasamy R, Gopal N, Kuzhandaivelu V. Biosensors in clinical chemistry: An overview. Adv Biomed Res 2014; 3:67. [PMID: 24627875 PMCID: PMC3950799 DOI: 10.4103/2277-9175.125848] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2012] [Accepted: 12/16/2012] [Indexed: 01/02/2023] Open
Abstract
Biosensors are small devices that employ biological/biochemical reactions for detecting target analytes. Basically, the device consists of a biocatalyst and a transducer. The biocatalyst may be a cell, tissue, enzyme or even an oligonucleotide. The transducers are mainly amperometric, potentiometric or optical. The classification of biosensors is based on (a) the nature of the recognition event or (b) the intimacy between the biocatalyst and the transducer. Bioaffinity and biocatalytic devices are examples for the former and the first, whereas second and third generation instruments are examples for the latter. Cell-based biosensors utilizing immobilized cells, tissues as also enzyme immunosensors and DNA biosensors find variegated uses in diagnostics. Enzyme nanoparticle-based biosensors make use of small particles in the nanometer scale and are currently making a mark in laboratory medicine. Nanotechnology can help in optimizing the diagnostic biochips, which would facilitate sensitive, rapid, accurate and precise bedside monitoring. Biosensors render themselves as capable diagnostic tools as they meet most of the above-mentioned criteria.
Collapse
Affiliation(s)
- Sathish Babu Murugaiyan
- Department of Biochemistry, Mahathma Gandhi Medical College and Research Institute, Pillayarkuppam, Puducherry, India
| | - Ramesh Ramasamy
- Department of Biochemistry, Mahathma Gandhi Medical College and Research Institute, Pillayarkuppam, Puducherry, India
| | - Niranjan Gopal
- Department of Biochemistry, Mahathma Gandhi Medical College and Research Institute, Pillayarkuppam, Puducherry, India
| | - V Kuzhandaivelu
- Department of Biochemistry, Mahathma Gandhi Medical College and Research Institute, Pillayarkuppam, Puducherry, India
| |
Collapse
|