1
|
Gong X, Zhang J, Zhu L, Bai S, Yu L, Sun Y. Fabrication of a Heptapeptide-Modified Poly(glycidyl Methac-Rylate) Nanosphere for Oriented Antibody Immobilization and Immunoassay. Molecules 2024; 29:4635. [PMID: 39407565 PMCID: PMC11477792 DOI: 10.3390/molecules29194635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Revised: 09/26/2024] [Accepted: 09/27/2024] [Indexed: 10/20/2024] Open
Abstract
Oriented antibody immobilization has been widely employed in immunoassays and immunodiagnoses due to its efficacy in identifying target antigens. Herein, a heptapeptide ligand, HWRGWVC (HC7), was coupled to poly(glycidyl methacrylate) (PGMA) nanospheres (PGMA-HC7). The antibody immobilization behavior and antigen recognition performance were investigated and compared with those on PGMA nanospheres by nonspecific adsorption and covalent coupling via carbodiimide chemistry. The antibodies tested included bovine, rabbit, and human immunoglobulin G (IgG), while the antigens included horseradish peroxidase (HRP) and β-2-Microglobulin (β2-MG). The nanospheres were characterized using zeta potential and particle size analyzers, scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectroscopy, and reversed-phase chromatography, proving each synthesis step was succeeded. Isothermal titration calorimetry assay demonstrated the strong affinity interaction between IgG and PGMA-HC7. Notably, PGMA-HC7 achieved rapid and extremely high IgG adsorption capacity (~3 mg/mg) within 5 min via a specific recognition via HC7 without nonspecific interactions. Moreover, the activities of immobilized anti-HRP and anti-β2-MG antibodies obtained via affinity binding were 1.5-fold and 2-fold higher than those of their covalent coupling counterparts. Further, the oriented-immobilized anti-β2-MG antibody on PGMA-HC7 exhibited excellent performance in antigen recognition with a linear detection range of 0-5.3 μg/mL, proving its great potential in immunoassay applications.
Collapse
Affiliation(s)
- Xiaoxing Gong
- Department of Biochemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China; (X.G.); (J.Z.); (L.Z.); (S.B.)
| | - Jie Zhang
- Department of Biochemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China; (X.G.); (J.Z.); (L.Z.); (S.B.)
| | - Liyan Zhu
- Department of Biochemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China; (X.G.); (J.Z.); (L.Z.); (S.B.)
| | - Shu Bai
- Department of Biochemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China; (X.G.); (J.Z.); (L.Z.); (S.B.)
- Key Laboratory of Systems Bioengineering and Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin 300350, China
| | - Linling Yu
- Department of Biochemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China; (X.G.); (J.Z.); (L.Z.); (S.B.)
- Key Laboratory of Systems Bioengineering and Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin 300350, China
| | - Yan Sun
- Department of Biochemical Engineering, School of Chemical Engineering and Technology, Tianjin University, Tianjin 300350, China; (X.G.); (J.Z.); (L.Z.); (S.B.)
- Key Laboratory of Systems Bioengineering and Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin 300350, China
| |
Collapse
|
2
|
Wang X, Kong F, Liu Y, Lv S, Zhang K, Sun S, Liu J, Wang M, Cai X, Jin H, Yan S, Luo J. 17β-estradiol biosensors based on different bioreceptors and their applications. Front Bioeng Biotechnol 2024; 12:1347625. [PMID: 38357703 PMCID: PMC10864596 DOI: 10.3389/fbioe.2024.1347625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 01/16/2024] [Indexed: 02/16/2024] Open
Abstract
17β-Estradiol (E2) is a critical sex steroid hormone, which has significant effects on the endocrine systems of both humans and animals. E2 is also believed to play neurotrophic and neuroprotective roles in the brain. Biosensors present a powerful tool to detect E2 because of their small, efficient, and flexible design. Furthermore, Biosensors can quickly and accurately obtain detection results with only a small sampling amount, which greatly meets the detection of the environment, food safety, medicine safety, and human body. This review focuses on previous studies of biosensors for detecting E2 and divides them into non-biometric sensors, enzyme biosensors, antibody biosensors, and aptamer biosensors according to different bioreceptors. The advantages, disadvantages, and design points of various bioreceptors for E2 detection are analyzed and summarized. Additionally, applications of different bioreceptors of E2 detection are presented and highlight the field of environmental monitoring, food and medicine safety, and disease detection in recent years. Finally, the development of E2 detection by biosensor is prospected.
Collapse
Affiliation(s)
- Xinyi Wang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
| | - Fanli Kong
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
| | - Yaoyao Liu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
| | - Shiya Lv
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
| | - Kui Zhang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
| | - Shutong Sun
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
| | - Juntao Liu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
| | - Mixia Wang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
| | - Xinxia Cai
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
| | - Hongyan Jin
- Obstetrics and Gynecology Department, Peking University First Hospital, Beijing, China
| | - Shi Yan
- Department of Thoracic Surgery II, Peking University Cancer Hospital & Institute, Beijing, China
| | - Jinping Luo
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing, China
| |
Collapse
|
3
|
Li Q, Dou L, Zhang Y, Luo L, Yang H, Wen K, Yu X, Shen J, Wang Z. A comprehensive review on the detection of Staphylococcus aureus enterotoxins in food samples. Compr Rev Food Sci Food Saf 2024; 23:e13264. [PMID: 38284582 DOI: 10.1111/1541-4337.13264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 10/12/2023] [Accepted: 10/15/2023] [Indexed: 01/30/2024]
Abstract
Staphylococcal enterotoxins (SEs), the major virulence factors of Staphylococcus aureus, cause a wide range of food poisoning and seriously threaten human health by infiltrating the food supply chain at different phases of manufacture, processes, distribution, and market. The significant prevalence of Staphylococcus aureus calls for efficient, fast, and sensitive methods for the early detection of SEs. Here, we provide a comprehensive review of the hazards of SEs in contaminated food, the characteristic and worldwide regulations of SEs, and various detection methods for SEs with extensive comparison and discussion of benefits and drawbacks, mainly including biological detection, genetic detection, and mass spectrometry detection and biosensors. We highlight the biosensors for the screening purpose of SEs, which are classified according to different recognition elements such as antibodies, aptamers, molecularly imprinted polymers, T-cell receptors, and transducers such as optical, electrochemical, and piezoelectric biosensors. We analyzed challenges of biosensors for the monitoring of SEs and conclude the trends for the development of novel biosensors should pay attention to improve samples pretreatment efficiency, employ innovative nanomaterials, and develop portable instruments. This review provides new information and insightful commentary, important to the development and innovation of further detection methods for SEs in food samples.
Collapse
Affiliation(s)
- Qing Li
- National Key Laboratory of Veterinary Public Health safety, College of Veterinary Medicine China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing, China
| | - Leina Dou
- National Key Laboratory of Veterinary Public Health safety, College of Veterinary Medicine China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing, China
| | - Yingjie Zhang
- National Key Laboratory of Veterinary Public Health safety, College of Veterinary Medicine China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing, China
| | - Liang Luo
- National Key Laboratory of Veterinary Public Health safety, College of Veterinary Medicine China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing, China
| | - Huijuan Yang
- National Key Laboratory of Veterinary Public Health safety, College of Veterinary Medicine China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing, China
| | - Kai Wen
- National Key Laboratory of Veterinary Public Health safety, College of Veterinary Medicine China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing, China
| | - Xuezhi Yu
- National Key Laboratory of Veterinary Public Health safety, College of Veterinary Medicine China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing, China
| | - Jianzhong Shen
- National Key Laboratory of Veterinary Public Health safety, College of Veterinary Medicine China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing, China
| | - Zhanhui Wang
- National Key Laboratory of Veterinary Public Health safety, College of Veterinary Medicine China Agricultural University, Beijing Key Laboratory of Detection Technology for Animal-Derived Food Safety, and Beijing Laboratory for Food Quality and Safety, Beijing, China
| |
Collapse
|
4
|
Kalita N, Gogoi S, Minteer SD, Goswami P. Advances in Bioelectrode Design for Developing Electrochemical Biosensors. ACS MEASUREMENT SCIENCE AU 2023; 3:404-433. [PMID: 38145027 PMCID: PMC10740130 DOI: 10.1021/acsmeasuresciau.3c00034] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 09/26/2023] [Accepted: 09/27/2023] [Indexed: 12/26/2023]
Abstract
The critical performance factors such as selectivity, sensitivity, operational and storage stability, and response time of electrochemical biosensors are governed mainly by the function of their key component, the bioelectrode. Suitable design and fabrication strategies of the bioelectrode interface are essential for realizing the requisite performance of the biosensors for their practical utility. A multifaceted attempt to achieve this goal is visible from the vast literature exploring effective strategies for preparing, immobilizing, and stabilizing biorecognition elements on the electrode surface and efficient transduction of biochemical signals into electrical ones (i.e., current, voltage, and impedance) through the bioelectrode interface with the aid of advanced materials and techniques. The commercial success of biosensors in modern society is also increasingly influenced by their size (and hence portability), multiplexing capability, and coupling in the interface of the wireless communication technology, which facilitates quick data transfer and linked decision-making processes in real-time in different areas such as healthcare, agriculture, food, and environmental applications. Therefore, fabrication of the bioelectrode involves careful selection and control of several parameters, including biorecognition elements, electrode materials, shape and size of the electrode, detection principles, and various fabrication strategies, including microscale and printing technologies. This review discusses recent trends in bioelectrode designs and fabrications for developing electrochemical biosensors. The discussions have been delineated into the types of biorecognition elements and their immobilization strategies, signal transduction approaches, commonly used advanced materials for electrode fabrication and techniques for fabricating the bioelectrodes, and device integration with modern electronic communication technology for developing electrochemical biosensors of commercial interest.
Collapse
Affiliation(s)
- Nabajyoti Kalita
- Department
of Biosciences and Bioengineering, Indian
Institute of Technology Guwahati, Guwahati, Assam 781039, India
| | - Sudarshan Gogoi
- Department
of Chemistry, Sadiya College, Chapakhowa, Assam 786157, India
| | - Shelley D. Minteer
- Department
of Chemistry, University of Utah, 315 S 1400 E, Salt Lake City, Utah 84112, United States
- Kummer
Institute Center for Resource Sustainability, Missouri University of Science and Technology, Rolla, Missouri 65409, United States
| | - Pranab Goswami
- Department
of Biosciences and Bioengineering, Indian
Institute of Technology Guwahati, Guwahati, Assam 781039, India
| |
Collapse
|
5
|
Zherdev AV, Dzantiev BB. Detection Limits of Immunoanalytical Systems: Limiting Factors and Methods of Reduction. JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1134/s1061934822040141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
6
|
Bai S, Zhang J, Zhu L, Gong X, Yu L, Sun Y. Characterization of a heptapeptide-modified microsphere for oriented antibody immobilization. J Pept Sci 2022; 28:e3411. [PMID: 35415855 DOI: 10.1002/psc.3411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Revised: 04/05/2022] [Accepted: 04/06/2022] [Indexed: 11/11/2022]
Abstract
Oriented immobilization of antibodies is important for the effective recognition of target antigens. In this paper, a heptapeptide ligand, HWRGWVC (HC7), was modified onto non-porous mono-sized poly (glyceryl methacrylate) (pGMA) microspheres (named pGMA-HC7) to explore the antibody immobilization behaviors. Characterization of the microspheres by particle size analyzer, scanning electron microscopy, Fourier transform infrared spectroscopy, and reversed-phase chromatography proved the success of each fabrication step. The capacity and activity of antibody immobilization through HC7 were studied using immunoglobulin G (IgG) as a model antibody and horseradish peroxidase (HRP) as a model antigen. Additionally, IgG immobilizations on pGMA microspheres by nonspecific adsorption and covalent coupling through carbodiimide chemistry were conducted for comparison. pGMA-HC7 exhibited an IgG adsorption capacity of 3-4 mg/g in 10 min by the specific binding of HC7 without nonspecific interactions. Notably, the ligand HC7 showed a by two orders of magnitude stronger affinity for IgG than its original hexapeptide ligand HWRGWV. Moreover, the capacity and activity of the immobilized anti-HRP antibody on pGMA-HC7 were 1.6-fold and 3-fold higher than those of the covalent coupling, respectively. The results proved the superior role of HWRGWVC in the affinity binding of antibody and the potential of pGMA-HC7-25 in immunoassay and immunodiagnostic applications.
Collapse
Affiliation(s)
- Shu Bai
- Department of Biochemical Engineering, School of Chemical Engineering and Technology and Key Laboratory of Systems Bioengineering and Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin, China
| | - Jie Zhang
- Department of Biochemical Engineering, School of Chemical Engineering and Technology and Key Laboratory of Systems Bioengineering and Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin, China
| | - Liyan Zhu
- Department of Biochemical Engineering, School of Chemical Engineering and Technology and Key Laboratory of Systems Bioengineering and Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin, China
| | - Xiaoxing Gong
- Department of Biochemical Engineering, School of Chemical Engineering and Technology and Key Laboratory of Systems Bioengineering and Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin, China
| | - Linling Yu
- Department of Biochemical Engineering, School of Chemical Engineering and Technology and Key Laboratory of Systems Bioengineering and Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin, China
| | - Yan Sun
- Department of Biochemical Engineering, School of Chemical Engineering and Technology and Key Laboratory of Systems Bioengineering and Frontiers Science Center for Synthetic Biology (Ministry of Education), Tianjin University, Tianjin, China
| |
Collapse
|
7
|
Arshavsky‐Graham S, Heuer C, Jiang X, Segal E. Aptasensors versus immunosensors-Which will prevail? Eng Life Sci 2022; 22:319-333. [PMID: 35382545 PMCID: PMC8961048 DOI: 10.1002/elsc.202100148] [Citation(s) in RCA: 31] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 12/21/2021] [Accepted: 12/24/2021] [Indexed: 12/11/2022] Open
Abstract
Since the invention of the first biosensors 70 years ago, they have turned into valuable and versatile tools for various applications, ranging from disease diagnosis to environmental monitoring. Traditionally, antibodies have been employed as the capture probes in most biosensors, owing to their innate ability to bind their target with high affinity and specificity, and are still considered as the gold standard. Yet, the resulting immunosensors often suffer from considerable limitations, which are mainly ascribed to the antibody size, conjugation chemistry, stability, and costs. Over the past decade, aptamers have emerged as promising alternative capture probes presenting some advantages over existing constraints of immunosensors, as well as new biosensing concepts. Herein, we review the employment of antibodies and aptamers as capture probes in biosensing platforms, addressing the main aspects of biosensor design and mechanism. We also aim to compare both capture probe classes from theoretical and experimental perspectives. Yet, we highlight that such comparisons are not straightforward, and these two families of capture probes should not be necessarily perceived as competing but rather as complementary. We, thus, elaborate on their combined use in hybrid biosensing schemes benefiting from the advantages of each biorecognition element.
Collapse
Affiliation(s)
- Sofia Arshavsky‐Graham
- Faculty of Biotechnology and Food EngineeringTechnion ‐ Israel Institute of TechnologyHaifaIsrael
| | - Christopher Heuer
- Faculty of Biotechnology and Food EngineeringTechnion ‐ Israel Institute of TechnologyHaifaIsrael
- Institute of Technical ChemistryLeibniz University HannoverHannoverGermany
| | - Xin Jiang
- Faculty of Biotechnology and Food EngineeringTechnion ‐ Israel Institute of TechnologyHaifaIsrael
| | - Ester Segal
- Faculty of Biotechnology and Food EngineeringTechnion ‐ Israel Institute of TechnologyHaifaIsrael
- Russell Berrie Nanotechnology InstituteTechnion ‐ Israel Institute of TechnologyHaifaIsrael
| |
Collapse
|
8
|
Drozd M, Karoń S, Malinowska E. Recent Advancements in Receptor Layer Engineering for Applications in SPR-Based Immunodiagnostics. SENSORS (BASEL, SWITZERLAND) 2021; 21:3781. [PMID: 34072572 PMCID: PMC8198293 DOI: 10.3390/s21113781] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 05/23/2021] [Accepted: 05/26/2021] [Indexed: 12/12/2022]
Abstract
The rapid progress in the development of surface plasmon resonance-based immunosensing platforms offers wide application possibilities in medical diagnostics as a label-free alternative to enzyme immunoassays. The early diagnosis of diseases or metabolic changes through the detection of biomarkers in body fluids requires methods characterized by a very good sensitivity and selectivity. In the case of the SPR technique, as well as other surface-sensitive detection strategies, the quality of the transducer-immunoreceptor interphase is crucial for maintaining the analytical reliability of an assay. In this work, an overview of general approaches to the design of functional SPR-immunoassays is presented. It covers both immunosensors, the design of which utilizes well-known and often commercially available substrates, as well as the latest solutions developed in-house. Various approaches employing chemical and passive binding, affinity-based antibody immobilization, and the introduction of nanomaterial-based surfaces are discussed. The essence of their influence on the improvement of the main analytical parameters of a given immunosensor is explained. Particular attention is paid to solutions compatible with the latest trends in the development of label-free immunosensors, such as platforms dedicated to real-time monitoring in a quasi-continuous mode, the use of in situ-generated receptor layers (elimination of the regeneration step), and biosensors using recombinant and labelled protein receptors.
Collapse
Affiliation(s)
- Marcin Drozd
- Faculty of Chemistry, The Chair of Medical Biotechnology, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland;
- Center for Advanced Materials and Technologies, Warsaw University of Technology, Poleczki 19, 02-822 Warsaw, Poland
| | - Sylwia Karoń
- Faculty of Chemistry, The Chair of Medical Biotechnology, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland;
- Center for Advanced Materials and Technologies, Warsaw University of Technology, Poleczki 19, 02-822 Warsaw, Poland
| | - Elżbieta Malinowska
- Faculty of Chemistry, The Chair of Medical Biotechnology, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland;
- Center for Advanced Materials and Technologies, Warsaw University of Technology, Poleczki 19, 02-822 Warsaw, Poland
| |
Collapse
|
9
|
Kakkar T, Keijzer C, Rodier M, Bukharova T, Taliansky M, Love AJ, Milner JJ, Karimullah AS, Barron LD, Gadegaard N, Lapthorn AJ, Kadodwala M. Superchiral near fields detect virus structure. LIGHT, SCIENCE & APPLICATIONS 2020; 9:195. [PMID: 33298854 PMCID: PMC7705013 DOI: 10.1038/s41377-020-00433-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 10/28/2020] [Accepted: 11/11/2020] [Indexed: 05/14/2023]
Abstract
Optical spectroscopy can be used to quickly characterise the structural properties of individual molecules. However, it cannot be applied to biological assemblies because light is generally blind to the spatial distribution of the component molecules. This insensitivity arises from the mismatch in length scales between the assemblies (a few tens of nm) and the wavelength of light required to excite chromophores (≥150 nm). Consequently, with conventional spectroscopy, ordered assemblies, such as the icosahedral capsids of viruses, appear to be indistinguishable isotropic spherical objects. This limits potential routes to rapid high-throughput portable detection appropriate for point-of-care diagnostics. Here, we demonstrate that chiral electromagnetic (EM) near fields, which have both enhanced chiral asymmetry (referred to as superchirality) and subwavelength spatial localisation (∼10 nm), can detect the icosahedral structure of virus capsids. Thus, they can detect both the presence and relative orientation of a bound virus capsid. To illustrate the potential uses of the exquisite structural sensitivity of subwavelength superchiral fields, we have used them to successfully detect virus particles in the complex milieu of blood serum.
Collapse
Affiliation(s)
- Tarun Kakkar
- School of Chemistry, Joseph Black Building, University of Glasgow, Glasgow, G12 8QQ, UK.
| | - Chantal Keijzer
- School of Chemistry, Joseph Black Building, University of Glasgow, Glasgow, G12 8QQ, UK.
- Institute of Molecular, Cell and Systems Biology and School of Life Sciences, University of Glasgow, G12 8QQ, Glasgow, UK.
| | - Marion Rodier
- School of Chemistry, Joseph Black Building, University of Glasgow, Glasgow, G12 8QQ, UK
| | | | - Michael Taliansky
- James Hutton Inst, Cell & Mol Sci, Dundee, DD2 5DA, UK
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry RAS, Moscow, 117997, Russia
| | - Andrew J Love
- James Hutton Inst, Cell & Mol Sci, Dundee, DD2 5DA, UK
| | - Joel J Milner
- Institute of Molecular, Cell and Systems Biology and School of Life Sciences, University of Glasgow, G12 8QQ, Glasgow, UK
| | - Affar S Karimullah
- School of Chemistry, Joseph Black Building, University of Glasgow, Glasgow, G12 8QQ, UK
| | - Laurence D Barron
- School of Chemistry, Joseph Black Building, University of Glasgow, Glasgow, G12 8QQ, UK
| | - Nikolaj Gadegaard
- School of Engineering, Rankine Building, University of Glasgow, Glasgow, G12 8LT, UK
| | - Adrian J Lapthorn
- School of Chemistry, Joseph Black Building, University of Glasgow, Glasgow, G12 8QQ, UK
| | - Malcolm Kadodwala
- School of Chemistry, Joseph Black Building, University of Glasgow, Glasgow, G12 8QQ, UK.
| |
Collapse
|
10
|
Shen Y, Xu L, Li Y. Biosensors for rapid detection of Salmonella in food: A review. Compr Rev Food Sci Food Saf 2020; 20:149-197. [PMID: 33443806 DOI: 10.1111/1541-4337.12662] [Citation(s) in RCA: 91] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Revised: 09/04/2020] [Accepted: 10/01/2020] [Indexed: 12/13/2022]
Abstract
Salmonella is one of the main causes of foodborne infectious diseases, posing a serious threat to public health. It can enter the food supply chain at various stages of production, processing, distribution, and marketing. High prevalence of Salmonella necessitates efficient and effective approaches for its identification, detection, and monitoring at an early stage. Because conventional methods based on plate counting and real-time polymerase chain reaction are time-consuming and laborious, novel rapid detection methods are urgently needed for in-field and on-line applications. Biosensors provide many advantages over conventional laboratory assays in terms of sensitivity, specificity, and accuracy, and show superiority in rapid response and potential portability. They are now recognized as promising alternative tools and one of the most on-site applicable and end user-accessible methods for rapid detection. In recent years, we have witnessed a flourishing of studies in the development of robust and elaborate biosensors for detection of Salmonella in food. This review aims to provide a comprehensive overview on Salmonella biosensors by highlighting different signal-transducing mechanisms (optical, electrochemical, piezoelectric, etc.) and critically analyzing its recent trends, particularly in combination with nanomaterials, microfluidics, portable instruments, and smartphones. Furthermore, current challenges are emphasized and future perspectives are discussed.
Collapse
Affiliation(s)
- Yafang Shen
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China.,Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, Arkansas
| | - Lizhou Xu
- Department of Materials, Imperial College London, London, UK
| | - Yanbin Li
- Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, Arkansas
| |
Collapse
|
11
|
Alipour E, Shariatpanahi SP, Ghourchian H, Piro B, Fathipour M, Boutorabi SM, Znoyko SL, Nikitin PI. Designing a magnetic inductive micro-electrode for virus monitoring: modelling and feasibility for hepatitis B virus. Mikrochim Acta 2020; 187:463. [PMID: 32686021 DOI: 10.1007/s00604-020-04429-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 07/06/2020] [Indexed: 12/13/2022]
Abstract
A simple model is designed for an inductive immunosensor in which the magnetic particles are attached to the bioreceptors to form a sandwich on the surface of an inductor. The inductor consists of a coil covered on a silicon oxide wafer. The coil comprises 250 turns of a planar gold wire, which is approximately 200 nm thick and 392 mm long, placed in a circle with a diameter of 2 mm. The model is well characterised by controlling the geometrical and electrical parameters and also the permeability of the magnetic material. To evaluate the feasibility of the model for virus monitoring, a novel inductive immunosensor is designed and for the first time applied for the detection of hepatitis B surface antigen (HBsAg). At first, Fab' segment of primary anti-HBsAg is immobilised on the coil. Then, the coil is exposed to HBsAg and the complex is introduced to a secondary antibody conjugated with magnetic particles to form an immune-sandwich. Finally, the influence of magnetic particles on the coil inductance is recorded and used as a signal for HBsAg detection. The magnetic inductive immunosensor showed specific responses toward HBsAg with the detection limit of 1 ng mL-1, linear range of 1 to 200 ng mL-1, and a sensitivity of 6 × 10-4 mL ng-1. The experimental results showed a very good agreement with simulation data indicating the compatibility of sensor sensitivity to the expected theoretical values. Graphical abstract.
Collapse
Affiliation(s)
- Elias Alipour
- Institute of Biochemistry and Biophysics (IBB), University of Tehran, P. O. Box 13145-1384, Tehran, Iran
| | - Seyed Peyman Shariatpanahi
- Institute of Biochemistry and Biophysics (IBB), University of Tehran, P. O. Box 13145-1384, Tehran, Iran
| | - Hedayatollah Ghourchian
- Institute of Biochemistry and Biophysics (IBB), University of Tehran, P. O. Box 13145-1384, Tehran, Iran.
| | - Benoit Piro
- Université de Paris, ITODYS, CNRS, F-75006, Paris, France
| | - Morteza Fathipour
- MEMS & NEMES Laboratory, Department of Electrical and Computer Engineering, University of Tehran, North kargar Ave., Tehran, Iran
| | | | - Sergey L Znoyko
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov St, Moscow, Russia, 119991
| | - Petr I Nikitin
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 38 Vavilov St, Moscow, Russia, 119991
| |
Collapse
|
12
|
Pohanka M. Immunoassay of interferon gamma by quartz crystal microbalance biosensor. Talanta 2020; 218:121167. [PMID: 32797920 DOI: 10.1016/j.talanta.2020.121167] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 05/08/2020] [Accepted: 05/14/2020] [Indexed: 12/13/2022]
Abstract
Interferon gamma (IFNγ) is a cytokine and an immunochemical marker that can be used for revealing of infectious diseases and especially for distinguishing of viral and some types of bacterial infections. Blood tests for IFNγ are typically based on immunoassays like Enzyme-Linked Immunosorbent Assay (ELISA). In this paper, a biosensor working on the principle of quartz crystal microbalance (QCM) was developed as an alternative to the standard analytical methods for IFNγ. The biosensor contained antibodies against IFNγ immobilized on QCM and also on gold nanoparticles. A sandwich containing QCM, gold nanoparticles and IFNγ was formed and formation of the sandwich caused decrease of oscillation frequency. The assay exerted limit of detection 5.7 pg/ml for a sample sized 50 μl and one measuring cycle was finished within 90 min. The assay by biosensor fully correlated to standard ELISA. In a conclusion, the biosensor appears to be a fully applicable analytical tool for a simple assay of IFNγ. Overall simplicity and no special requirement on staff and equipment are the major advantages of the here presented assay.
Collapse
Affiliation(s)
- Miroslav Pohanka
- Faculty of Military Health Sciences, University of Defense, Trebesska 1575, Hradec Kralove, CZ-50001, Czech Republic.
| |
Collapse
|
13
|
Ali M, Sajid M, Khalid MAU, Kim SW, Lim JH, Huh D, Choi KH. A fluorescent lateral flow biosensor for the quantitative detection of Vaspin using upconverting nanoparticles. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 226:117610. [PMID: 31606675 DOI: 10.1016/j.saa.2019.117610] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Revised: 08/19/2019] [Accepted: 10/06/2019] [Indexed: 06/10/2023]
Abstract
Vaspin is a protein present in human serum that can cause type-2 diabetes, obesity, and other cardiovascular diseases. We report fluorescent upconverting nanoparticles (UCNPs)-based lateral flow biosensor for ultrasensitive detection of Vaspin. A pair (primary and secondary) of cognate aptamers was used that has duo binding with Vaspin. UCNPs with a diameter of around 100 nm were used as a tag to label a detection probe (secondary aptamer). A primary aptamer (capture probe) was immobilized on the test zone. Sandwich type hybridization reactions among the conjugate probe, target Vaspin, and primary aptamer were performed on the lateral flow biosensor. In the presence of target Vaspin, UCNPs were captured on the test zone of the biosensor and the fluorescent intensity of the captured UCNPs was measured through a colorimetric app under NIR. Fluorescence intensity indicates the quantity of Vaspin present in the sample. A range of Vaspin concentration across 0.1-55 ng ml-1 with a Limit of detection (LOD) 39 pg ml-1 was tested through this UCNPs based LFSA with high sensitivity, reproducibility and repeatability, whereas it's actual range in human blood is from 0.1 to 7 ng ml-1. Therefore, this research provides a well-suited lateral flow strip with an ultrasensitive and low-cost approach for the early diagnosis of type-2 diabetes and this could be applied to any targets with a duo of aptamers generated.
Collapse
Affiliation(s)
- Muhsin Ali
- Department of Mechatronics Engineering, Jeju National University, Jeju, South Korea
| | - Memoon Sajid
- Department of Mechatronics Engineering, Jeju National University, Jeju, South Korea; GIK Institute of Engineering Sciences and Technology Topi, Swabi, KP, Pakistan.
| | | | - Soo Wan Kim
- Department of Mechatronics Engineering, Jeju National University, Jeju, South Korea.
| | - Jong Hwan Lim
- Department of Mechatronics Engineering, Jeju National University, Jeju, South Korea.
| | - Dongeun Huh
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Kyung Hyun Choi
- Department of Mechatronics Engineering, Jeju National University, Jeju, South Korea.
| |
Collapse
|
14
|
Rodier M, Keijzer C, Milner J, Karimullah AS, Barron LD, Gadegaard N, Lapthorn AJ, Kadodwala M. Probing Specificity of Protein-Protein Interactions with Chiral Plasmonic Nanostructures. J Phys Chem Lett 2019; 10:6105-6111. [PMID: 31549842 DOI: 10.1021/acs.jpclett.9b02288] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Protein-protein interactions (PPIs) play a pivotal role in many biological processes. Discriminating functionally important well-defined protein-protein complexes formed by specific interactions from random aggregates produced by nonspecific interactions is therefore a critical capability. While there are many techniques which enable rapid screening of binding affinities in PPIs, there is no generic spectroscopic phenomenon which provides rapid characterization of the structure of protein-protein complexes. In this study we show that chiral plasmonic fields probe the structural order and hence the level of PPI specificity in a model antibody-antigen system. Using surface-immobilized Fab' fragments of polyclonal rabbit IgG antibodies with high specificity for bovine serum albumin (BSA), we show that chiral plasmonic fields can discriminate between a structurally anisotropic ensemble of BSA-Fab' complexes and random ovalbumin (OVA)-Fab' aggregates, demonstrating their potential as the basis of a useful proteomic technology for the initial rapid high-throughput screening of PPIs.
Collapse
Affiliation(s)
- Marion Rodier
- School of Chemistry, Joseph Black Building , University of Glasgow , Glasgow G12 8QQ , U.K
| | - Chantal Keijzer
- School of Chemistry, Joseph Black Building , University of Glasgow , Glasgow G12 8QQ , U.K
- Institute of Molecular, Cell and Systems Biology , University of Glasgow , Glasgow G12 8TA , U.K
| | - Joel Milner
- Institute of Molecular, Cell and Systems Biology , University of Glasgow , Glasgow G12 8TA , U.K
| | - Affar S Karimullah
- School of Chemistry, Joseph Black Building , University of Glasgow , Glasgow G12 8QQ , U.K
| | - Laurence D Barron
- School of Chemistry, Joseph Black Building , University of Glasgow , Glasgow G12 8QQ , U.K
| | - Nikolaj Gadegaard
- School of Engineering, Rankine Building , University of Glasgow , Glasgow G12 8LT , U.K
| | - Adrian J Lapthorn
- School of Chemistry, Joseph Black Building , University of Glasgow , Glasgow G12 8QQ , U.K
| | - Malcolm Kadodwala
- School of Chemistry, Joseph Black Building , University of Glasgow , Glasgow G12 8QQ , U.K
| |
Collapse
|
15
|
Duran B, Castañeda E, Armijo F. Development of an electrochemical impedimetric immunosensor for Corticotropin Releasing Hormone (CRH) using half-antibody fragments as elements of biorecognition. Biosens Bioelectron 2019; 131:171-177. [DOI: 10.1016/j.bios.2019.02.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 02/05/2019] [Accepted: 02/12/2019] [Indexed: 12/31/2022]
|
16
|
Walper SA, Lasarte Aragonés G, Sapsford KE, Brown CW, Rowland CE, Breger JC, Medintz IL. Detecting Biothreat Agents: From Current Diagnostics to Developing Sensor Technologies. ACS Sens 2018; 3:1894-2024. [PMID: 30080029 DOI: 10.1021/acssensors.8b00420] [Citation(s) in RCA: 88] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Although a fundamental understanding of the pathogenicity of most biothreat agents has been elucidated and available treatments have increased substantially over the past decades, they still represent a significant public health threat in this age of (bio)terrorism, indiscriminate warfare, pollution, climate change, unchecked population growth, and globalization. The key step to almost all prevention, protection, prophylaxis, post-exposure treatment, and mitigation of any bioagent is early detection. Here, we review available methods for detecting bioagents including pathogenic bacteria and viruses along with their toxins. An introduction placing this subject in the historical context of previous naturally occurring outbreaks and efforts to weaponize selected agents is first provided along with definitions and relevant considerations. An overview of the detection technologies that find use in this endeavor along with how they provide data or transduce signal within a sensing configuration follows. Current "gold" standards for biothreat detection/diagnostics along with a listing of relevant FDA approved in vitro diagnostic devices is then discussed to provide an overview of the current state of the art. Given the 2014 outbreak of Ebola virus in Western Africa and the recent 2016 spread of Zika virus in the Americas, discussion of what constitutes a public health emergency and how new in vitro diagnostic devices are authorized for emergency use in the U.S. are also included. The majority of the Review is then subdivided around the sensing of bacterial, viral, and toxin biothreats with each including an overview of the major agents in that class, a detailed cross-section of different sensing methods in development based on assay format or analytical technique, and some discussion of related microfluidic lab-on-a-chip/point-of-care devices. Finally, an outlook is given on how this field will develop from the perspective of the biosensing technology itself and the new emerging threats they may face.
Collapse
Affiliation(s)
- Scott A. Walper
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| | - Guillermo Lasarte Aragonés
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- College of Science, George Mason University Fairfax, Virginia 22030, United States
| | - Kim E. Sapsford
- OMPT/CDRH/OIR/DMD Bacterial Respiratory and Medical Countermeasures Branch, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Carl W. Brown
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- College of Science, George Mason University Fairfax, Virginia 22030, United States
| | - Clare E. Rowland
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- National Research Council, Washington, D.C. 20036, United States
| | - Joyce C. Breger
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| | - Igor L. Medintz
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| |
Collapse
|
17
|
Pont L, Benavente F, Barbosa J, Sanz-Nebot V. On-line immunoaffinity solid-phase extraction capillary electrophoresis mass spectrometry using Fab´antibody fragments for the analysis of serum transthyretin. Talanta 2017; 170:224-232. [DOI: 10.1016/j.talanta.2017.03.104] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Revised: 03/29/2017] [Accepted: 03/31/2017] [Indexed: 02/08/2023]
|
18
|
Surface engineering of poly(methylmethacrylate): Effects on fluorescence immunoassay. Biointerphases 2017; 12:02C415. [PMID: 28587470 DOI: 10.1116/1.4984010] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The authors present surface engineering modifications through chemistry of poly(methylmethacrylate) (PMMA) that have dramatic effects on the result of surface-bound fluorescence immunoassays, both for specific and nonspecific signals. The authors deduce the most important effect to be clustering of antibodies on the surface leading to significant self-quenching. Secondary effects are attributable to the formation of sparse multilayers of antibody. The authors compare PMMA as an antibody support surface with ultraviolet-ozone oxidized PMMA and also to substrates that were, after the oxidation, surface modified by a four-unit poly(ethyleneglycol) carboxylic acid (PEG4), a branched tricarboxylic acid, and a series of carboxylic acid-terminated dendrimers, from generation 1.5 to 5.5. Fluorescence immunoassay and neutron reflectometry were used to compare the apparent antibody surface loading, antigen binding and nonspecific binding on these various surfaces using anti-human IgG as a model antibody, chemically coupled to the surface by amide formation. Simple physical adsorption of the antibody on PMMA resulted in a thick antibody multilayer with small antigen binding capacity. On the carboxylated surfaces, with chemical coupling, a simple monolayer was formed. The authors deduce that antibody clustering was driven by conformational inflexibility and high carboxylate density. The PEG4-modified surface was the most conformationally flexible. The dendrimer-modified interfaces showed a collapse and densification. In fluorescence immunoassay, the optimal combination of high specific and low nonspecific fluorescence signal was found for the G3.5 dendrimer.
Collapse
|
19
|
Orientation and characterization of immobilized antibodies for improved immunoassays (Review). Biointerphases 2017; 12:02D301. [DOI: 10.1116/1.4978435] [Citation(s) in RCA: 202] [Impact Index Per Article: 28.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
20
|
Direct immobilization of antibodies on Zn-doped Fe 3 O 4 nanoclusters for detection of pathogenic bacteria. Anal Chim Acta 2017; 952:81-87. [DOI: 10.1016/j.aca.2016.11.041] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Revised: 11/17/2016] [Accepted: 11/18/2016] [Indexed: 12/11/2022]
|
21
|
Site-directed introduction of disulfide groups on antibodies for highly sensitive immunosensors. Anal Bioanal Chem 2016; 408:5337-46. [DOI: 10.1007/s00216-016-9630-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Revised: 05/08/2016] [Accepted: 05/11/2016] [Indexed: 12/22/2022]
|
22
|
Crivianu-Gaita V, Thompson M. Aptamers, antibody scFv, and antibody Fab' fragments: An overview and comparison of three of the most versatile biosensor biorecognition elements. Biosens Bioelectron 2016; 85:32-45. [PMID: 27155114 DOI: 10.1016/j.bios.2016.04.091] [Citation(s) in RCA: 165] [Impact Index Per Article: 20.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Revised: 04/11/2016] [Accepted: 04/26/2016] [Indexed: 01/14/2023]
Abstract
The choice of biosensing elements is crucial for the development of the optimal biosensor. Three of the most versatile biosensing elements are antibody single-chain Fv fragments (scFv), antibody fragment-antigen binding (Fab') units, and aptamers. This article provides an overview of these three biorecognition elements with respects to their synthesis/engineering, various immobilization techniques, and examples of their use in biosensors. Furthermore, the final section of the review compares and contrasts their characteristics (time/cost of development, ease and variability of immobilization, affinity, stability) illustrating their advantages and disadvantages. Overall, scFv fragments are found to display the highest customizability (i.e. addition of functional groups, immobilizing peptides, etc.) due to recombinant synthesis techniques. If time and cost are an issue in the development of the biosensor, Fab' fragments should be chosen as they are relatively cheap and can be developed quickly from whole antibodies (several days). However, if there are sufficient funds and time is not a factor, aptamers should be utilized as they display the greatest affinity towards their target analytes and are extremely stable (excellent biosensor regenerability).
Collapse
Affiliation(s)
| | - Michael Thompson
- Department of Chemistry, University of Toronto, Toronto, ON, M5S 3H6, Canada.
| |
Collapse
|
23
|
Asymmetric Mach-Zehnder Interferometer Based Biosensors for Aflatoxin M1 Detection. BIOSENSORS-BASEL 2016; 6:bios6010001. [PMID: 26751486 PMCID: PMC4810393 DOI: 10.3390/bios6010001] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2015] [Revised: 12/22/2015] [Accepted: 12/30/2015] [Indexed: 11/21/2022]
Abstract
In this work, we present a study of Aflatoxin M1 detection by photonic biosensors based on Si3N4 Asymmetric Mach–Zehnder Interferometer (aMZI) functionalized with antibodies fragments (Fab′). We measured a best volumetric sensitivity of 104 rad/RIU, leading to a Limit of Detection below 5 × 10−7 RIU. On sensors functionalized with Fab′, we performed specific and non-specific sensing measurements at various toxin concentrations. Reproducibility of the measurements and re-usability of the sensor were also investigated.
Collapse
|
24
|
Crivianu-Gaita V, Aamer M, Posaratnanathan RT, Romaschin A, Thompson M. Acoustic wave biosensor for the detection of the breast and prostate cancer metastasis biomarker protein PTHrP. Biosens Bioelectron 2015; 78:92-99. [PMID: 26594891 DOI: 10.1016/j.bios.2015.11.031] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Revised: 11/02/2015] [Accepted: 11/10/2015] [Indexed: 01/15/2023]
Abstract
There are currently no biosensors that are able to reliably detect the process of cancer metastasis. We describe the first label-free real-time ultra-high frequency acoustic wave biosensor prototype capable of detecting the breast and prostate cancer metastasis biomarker, parathyroid hormone-related peptide (PTHrP). Two different linkers - 11-trichlorosilyl-undecanoic acid pentafluorophenyl ester (PFP) and S-(11-trichlorosilyl-undecanyl)-benzothiosulfonate (TUBTS) - were used to immobilize whole anti-PTHrP antibodies and Fab' fragments to surfaces as biorecognition elements. The biosensor surfaces were optimized using X-ray photoelectron spectroscopy (XPS) and the ultra-high frequency electromagnetic piezoelectric acoustic sensor (EMPAS). One optimized whole antibody-based surface (PFP/protein G'/whole antibodies/ethanolamine) and one optimized Fab' fragment-based surface (TUBTS/Fab' fragments) were tested as biosensors. It was determined that an in-line injection of bovine serum albumin prior to analyte injection yielded the most minimally fouling surfaces. Each surface was tested with no mass amplification and with sandwich-type secondary antibody mass amplification. The whole antibody-based mass-amplified biosensor yielded the lowest limit of detection (61 ng/mL), highest sensitivity, and a linear range from 61 ng/mL to 100 μg/mL. However, the Fab' fragment-based biosensor displayed better regenerability as a loss of ~20% of the initial analyte signal intensity was observed with each subsequent injection. The whole antibody-based biosensor was only capable of producing an analyte signal in the first injection.
Collapse
Affiliation(s)
| | - Mohamed Aamer
- Department of Chemistry, University of Toronto, Toronto, ON, Canada M5S 3H6
| | | | | | - Michael Thompson
- Department of Chemistry, University of Toronto, Toronto, ON, Canada M5S 3H6.
| |
Collapse
|
25
|
Enzyme-triggered tyramine-enzyme repeats on prussian blue-gold hybrid nanostructures for highly sensitive electrochemical immunoassay of tissue polypeptide antigen. Biosens Bioelectron 2015; 73:167-173. [DOI: 10.1016/j.bios.2015.05.057] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2015] [Revised: 05/15/2015] [Accepted: 05/26/2015] [Indexed: 11/20/2022]
|
26
|
Ravindranath RR, Romaschin A, Thompson M. In vitro and in vivo cell-capture strategies using cardiac stent technology - A review. Clin Biochem 2015; 49:186-91. [PMID: 26474510 DOI: 10.1016/j.clinbiochem.2015.09.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2015] [Revised: 09/25/2015] [Accepted: 09/26/2015] [Indexed: 01/23/2023]
Abstract
Stenosis is a symptom of coronary artery disease (CAD), and is caused by narrowing of arteries in the heart. Over the last several decades, medical implants such as cardiac stents have been developed to counter stenosis. Upon implantation of a stent to open up a restricted artery, narrowing of the artery can reoccur (restenosis), due to an immune response launched by the body towards the stent. Currently, restenosis is a major health concern for patients who have undergone heart surgery for coronary artery disease. Recently, there have been new methods developed to combat restenosis, which have shown potential signs of success. One proposed method is the use of stents to capture cells, thereby reducing immune response. This review will explore the different methods for cell capture both in vitro and in vivo. Biological modifications of the stent will be surveyed, as well as the use of surface science to immobilize biological probes. Immobilization of proteins and nucleotides, as well as use of magnetic field are all methods that will be further discussed. Finally, concluding remarks and future prospects will be presented.
Collapse
Affiliation(s)
- Rohan R Ravindranath
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario M5S 3H6, Canada; Keenan Research Centre and Clinical Biochemistry, St. Michael's Hospital, 30 Bond Street, Toronto, Ontario M5B 1W8, Canada
| | - Alexander Romaschin
- Keenan Research Centre and Clinical Biochemistry, St. Michael's Hospital, 30 Bond Street, Toronto, Ontario M5B 1W8, Canada
| | - Michael Thompson
- Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario M5S 3H6, Canada.
| |
Collapse
|
27
|
Vossler JD, Min Ju Y, Williams JK, Goldstein S, Hamlin J, Lee SJ, Yoo JJ, Atala A. CD133 antibody conjugation to decellularized human heart valves intended for circulating cell capture. ACTA ACUST UNITED AC 2015; 10:055001. [PMID: 26333364 DOI: 10.1088/1748-6041/10/5/055001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The long term efficacy of tissue based heart valve grafts may be limited by progressive degeneration characterized by immune mediated inflammation and calcification. To avoid this degeneration, decellularized heart valves with functionalized surfaces capable of rapid in vivo endothelialization have been developed. The aim of this study is to examine the capacity of CD133 antibody-conjugated valve tissue to capture circulating endothelial progenitor cells (EPCs). Decellularized human pulmonary valve tissue was conjugated with CD133 antibody at varying concentrations and exposed to CD133 expressing NTERA-2 cl.D1 (NT2) cells in a microflow chamber. The amount of CD133 antibody conjugated on the valve tissue surface and the number of NT2 cells captured in the presence of shear stress was measured. Both the amount of CD133 antibody conjugated to the valve leaflet surface and the number of adherent NT2 cells increased as the concentration of CD133 antibody present in the surface immobilization procedure increased. The data presented in this study support the hypothesis that the rate of CD133(+) cell adhesion in the presence of shear stress to decellularized heart valve tissue functionalized by CD133 antibody conjugation increases as the quantity of CD133 antibody conjugated to the tissue surface increases.
Collapse
Affiliation(s)
- John D Vossler
- Wake Forest Institute for Regenerative Medicine and, Wake Forest School of Medicine, Medical Center Boulevard, Winston-Salem, NC 27157, USA. Department of General Surgery, Wake Forest School of Medicine, Medical Center Boulevard, Winston-Salem, NC 27157, USA
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Pan TM, Lin TW, Chen CY. Label-free detection of rheumatoid factor using YbYxOy electrolyte–insulator–semiconductor devices. Anal Chim Acta 2015; 891:304-11. [DOI: 10.1016/j.aca.2015.08.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2015] [Revised: 08/11/2015] [Accepted: 08/13/2015] [Indexed: 11/26/2022]
|
29
|
Bhadra P, Shajahan MS, Bhattacharya E, Chadha A. Studies on varying n-alkanethiol chain lengths on a gold coated surface and their effect on antibody–antigen binding efficiency. RSC Adv 2015. [DOI: 10.1039/c5ra11725a] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Antibody immobilization efficiency varied with the SAM of n-alkanethiols. However, this did not necessarily result in a corresponding increase in antigen binding.
Collapse
Affiliation(s)
- P. Bhadra
- Centre for NEMS and Nanophotonics
- Indian Institute of Technology Madras
- Chennai 600 036
- India
| | - M. S. Shajahan
- Centre for NEMS and Nanophotonics
- Indian Institute of Technology Madras
- Chennai 600 036
- India
| | - E. Bhattacharya
- Centre for NEMS and Nanophotonics
- Indian Institute of Technology Madras
- Chennai 600 036
- India
- Department of Electrical Engineering
| | - A. Chadha
- Centre for NEMS and Nanophotonics
- Indian Institute of Technology Madras
- Chennai 600 036
- India
- Department of Biotechnology
| |
Collapse
|