1
|
Yu S, Dai W, Su C, Milosavic N, Wang Z, Wang X, Zhu Y, He M, Landry DW, Stojanovic MN, Lin Q. An Internally Attached Aptameric Graphene Nanosensor for Sensitive Vasopressin Measurement in Critical Patient Monitoring. ACS Sens 2024; 9:4915-4923. [PMID: 39268764 DOI: 10.1021/acssensors.4c01519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/15/2024]
Abstract
This paper presents an aptameric graphene nanosensor for rapid and sensitive measurement of arginine vasopressin (AVP) toward continuous monitoring of critical care patients. The nanosensor is a field-effect transistor (FET) with monolayer graphene as the conducting channel and is functionalized with a new custom-designed aptamer for specific AVP recognition. Binding between the aptamer and AVP induces a change in the carrier density in the graphene and resulting in measurable changes in FET characteristics for determination of the AVP concentration. The aptamer, based on the natural enantiomer D-deoxyribose, possess optimized kinetic binding properties and is attached at an internal position to the graphene for enhanced sensitivity to low concentrations of AVP. Experimental results show that this aptameric graphene nanosensor is highly sensitive (with a limit of detection of 0.3 pM and a resolution of 0.1 pM) to AVP, and rapidly responsive (within 90 s) to both increasing and decreasing AVP concentration changes. The device is also reversable (within 4%), repeatable (within 4%) and reproducible (within 5%) in AVP measurements.
Collapse
Affiliation(s)
- Shifeng Yu
- College of Mechanical and Vehicle Engineering, Chongqing University, Chongqing 400044, China
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Wenting Dai
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Chao Su
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
- Department of Power and Energy Engineering, Xian Jiaotong University, Xian, Shaanxi 710049, China
| | - Nenad Milosavic
- Department of Medicine, Columbia University, New York, New York 10032, United States
| | - Ziran Wang
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Xuejun Wang
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Yibo Zhu
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Maogang He
- Department of Power and Energy Engineering, Xian Jiaotong University, Xian, Shaanxi 710049, China
| | - Donald W Landry
- Department of Medicine, Columbia University, New York, New York 10032, United States
| | - Milan N Stojanovic
- Department of Medicine, Columbia University, New York, New York 10032, United States
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| |
Collapse
|
2
|
Chieng A, Wan Z, Wang S. Recent Advances in Real-Time Label-Free Detection of Small Molecules. BIOSENSORS 2024; 14:80. [PMID: 38391999 PMCID: PMC10886562 DOI: 10.3390/bios14020080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 01/27/2024] [Accepted: 01/30/2024] [Indexed: 02/24/2024]
Abstract
The detection and analysis of small molecules, typically defined as molecules under 1000 Da, is of growing interest ranging from the development of small-molecule drugs and inhibitors to the sensing of toxins and biomarkers. However, due to challenges such as their small size and low mass, many biosensing technologies struggle to have the sensitivity and selectivity for the detection of small molecules. Notably, their small size limits the usage of labeled techniques that can change the properties of small-molecule analytes. Furthermore, the capability of real-time detection is highly desired for small-molecule biosensors' application in diagnostics or screening. This review highlights recent advances in label-free real-time biosensing technologies utilizing different types of transducers to meet the growing demand for small-molecule detection.
Collapse
Affiliation(s)
- Andy Chieng
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, Tempe, AZ 85287, USA; (A.C.); (Z.W.)
- School of Molecular Science, Arizona State University, Tempe, AZ 85287, USA
| | - Zijian Wan
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, Tempe, AZ 85287, USA; (A.C.); (Z.W.)
| | - Shaopeng Wang
- Center for Bioelectronics and Biosensors, Biodesign Institute, Arizona State University, Tempe, AZ 85287, USA; (A.C.); (Z.W.)
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ 85287, USA
| |
Collapse
|
3
|
Wang C, Wang T, Gao Y, Tao Q, Ye W, Jia Y, Zhao X, Zhang B, Zhang Z. Multiplexed immunosensing of cancer biomarkers on a split-float-gate graphene transistor microfluidic biochip. LAB ON A CHIP 2024; 24:317-326. [PMID: 38087953 DOI: 10.1039/d3lc00709j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/18/2024]
Abstract
This work reports the development of a novel microfluidic biosensor using a graphene field-effect transistor (GFET) design for the parallel label-free analysis of multiple biomarkers. Overcoming the persistent challenge of constructing μm2-sized FET sensitive interfaces that incorporate multiple receptors, we implement a split-float-gate structure that enables the manipulation of multiplexed biochemical functionalization using microfluidic channels. Immunoaffinity biosensing experiments are conducted using the mixture samples containing three liver cancer biomarkers, carcinoembryonic antigen (CEA), α-fetoprotein (AFP), and parathyroid hormone (PTH). The results demonstrate the capability of our label-free biochip to quantitatively detect multiple target biomarkers simultaneously by observing the kinetics in 10 minutes, with the detection limit levels in the nanomolar range. This microfluidic biosensor provides a valuable analytical tool for rapid multi-target biosensing, which can be potentially utilized for domiciliary tests of cancer screening and prognosis, obviating the need for sophisticated instruments and professional operations in hospitals.
Collapse
Affiliation(s)
- Cheng Wang
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin 300387, China.
- Department of Intelligence Science and Technology, College of Artificial Intelligence, Tianjin Normal University, Tianjin 300387, China
| | - Tao Wang
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin 300387, China.
- Department of Communication Engineering, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin 300387, China
| | - Yujing Gao
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin 300387, China.
- Department of Intelligence Science and Technology, College of Artificial Intelligence, Tianjin Normal University, Tianjin 300387, China
| | - Qiya Tao
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin 300387, China.
- Department of Communication Engineering, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin 300387, China
| | - Weixiang Ye
- Center for Theoretical Physics, Hainan University, Haikou 570228, China.
- Department of Physics, School of Physical Science and Optoelectrical Engineering, Hainan University, Haikou 570228, China
| | - Yuan Jia
- Industrialization Center of Micro/Nano ICs and Devices, Sino-German College of Intelligent Manufacturing, Shenzhen Technology University, Shenzhen 518118, China.
| | - Xiaonan Zhao
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin 300387, China.
- Department of Communication Engineering, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin 300387, China
| | - Bo Zhang
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin 300387, China.
- Department of Communication Engineering, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin 300387, China
| | - Zhixing Zhang
- Industrialization Center of Micro/Nano ICs and Devices, Sino-German College of Intelligent Manufacturing, Shenzhen Technology University, Shenzhen 518118, China.
| |
Collapse
|
4
|
Dwijendra NKA, Patra I, Ahmed YM, Hasan YM, Najm ZM, Al Mashhadani ZI, Kumar A. Carbonyl sulfide gas detection by pure, Zn- and Cd-decorated AlP nano-sheet. MONATSHEFTE FUR CHEMIE 2022. [DOI: 10.1007/s00706-022-02961-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
5
|
Zhang M, Li Z, Jia Y, Wang F, Tian J, Zhang C, Han T, Xing R, Ye W, Wang C. Observing Mesoscopic Nucleic Acid Capacitance Effect and Mismatch Impact via Graphene Transistors. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2105890. [PMID: 35072345 DOI: 10.1002/smll.202105890] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 12/05/2021] [Indexed: 06/14/2023]
Abstract
This work reports a molecular-scale capacitance effect of the double helical nucleic acid duplex structure for the first time. By quantitatively conducting large sample measurements of the electrostatic field effect using a type of high-accuracy graphene transistor biosensor, an unusual charge-transport behavior is observed in which the end-immobilized nucleic acid duplexes can store a part of ionization electrons like molecular capacitors, other than electric conductors. To elucidate this discovery, a cascaded capacitive network model is proposed as a novel equivalent circuit of nucleic acid duplexes, expanding the point-charge approximation model, by which the partial charge-transport observation is reasonably attributed to an electron-redistribution behavior within the capacitive network. Furthermore, it is experimentally confirmed that base-pair mismatches hinder the charge transport in double helical duplexes, and lead to directly identifiable alterations in electrostatic field effects. The bioelectronic principle of mismatch impact is also self-consistently explained by the newly proposed capacitive network model. The mesoscopic nucleic acid capacitance effect may enable a new kind of label-free nucleic acid analysis tool based on electronic transistor devices. The in situ and real-time nucleic acid detections for virus biomarkers, somatic mutations, and genome editing off-target may thus be predictable.
Collapse
Affiliation(s)
- Mingfeng Zhang
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin, 300387, China
| | - Zhibo Li
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin, 300387, China
| | - Yuan Jia
- Industrialization Center of Micro & Nano ICs and Devices Sino-German College of Intelligent Manufacturing, Shenzhen Technology University, Shenzhen, 518118, China
| | - Fuquan Wang
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin, 300387, China
| | - Jinpeng Tian
- Industrialization Center of Micro & Nano ICs and Devices Sino-German College of Intelligent Manufacturing, Shenzhen Technology University, Shenzhen, 518118, China
| | - Cuiping Zhang
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin, 300387, China
| | - Tingting Han
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin, 300387, China
- Department of Intelligence Science and Technology, College of Artificial Intelligence, Tianjin Normal University, Tianjin, 300387, China
| | - Ruiqing Xing
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin, 300387, China
- Department of Intelligence Science and Technology, College of Artificial Intelligence, Tianjin Normal University, Tianjin, 300387, China
| | - Weixiang Ye
- Department of Physics, School of Science, Hainan University, Haikou, 570228, China
- Key Laboratory of Engineering Modeling and Statistical Computation of Hainan Province, School of Science, Hainan University, Haikou, 570228, China
| | - Cheng Wang
- Tianjin Key Laboratory of Wireless Mobile Communications and Power Transmission, College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin, 300387, China
- Department of Intelligence Science and Technology, College of Artificial Intelligence, Tianjin Normal University, Tianjin, 300387, China
| |
Collapse
|
6
|
The role of graphene patterning in field-effect transistor sensors to detect the tau protein for Alzheimer's disease: Simplifying the immobilization process and improving the performance of graphene-based immunosensors. Biosens Bioelectron 2021; 192:113519. [PMID: 34333316 DOI: 10.1016/j.bios.2021.113519] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 07/14/2021] [Accepted: 07/16/2021] [Indexed: 11/23/2022]
Abstract
We report the improvement in the sensing performance of electrolyte-gated graphene field-effect transistor (FET) sensors capable of detecting tau protein through a simplified, linker-free, anti-tau antibody immobilization process. For most of the graphene-based immunosensor, linkers, such as pyrenebutanoic acid, succinimidyl ester (PSE) must be used to the graphene surface, while the other side of linkers serves to capture the antibodies that can specifically interact with the target biomarker. In this study, graphene was patterned into eight different types and linker-free patterned graphene FET sensors were fabricated to verify their detection performance. The linker-free antibody immobilization to patterned graphene exhibited that the antibody was immobilized to the edge defect and had a doping-like behaviors on graphene. As the tau protein concentration in the electrolyte increased from 10 fg/ml to 1 ng/ml, the performances, charge neutral point shift and current change rate of the patterned graphene sensors without linkers were enhanced 2-3 times compared to a pristine graphene sensor with the PSE linker. Moreover, tau protein in the plasma of five Alzheimer's disease patients was measured using a linker-free patterned graphene sensor. It shows a 3-4 times higher current change rate than that of pristine graphene sensor with the PSE linker. Since the antibody is immobilized directly without a linker, a patterned graphene sensor without a linker can operate more sensitively in higher ionic concentration electrolyte.
Collapse
|
7
|
Hao Z, Luo Y, Huang C, Wang Z, Song G, Pan Y, Zhao X, Liu S. An Intelligent Graphene-Based Biosensing Device for Cytokine Storm Syndrome Biomarkers Detection in Human Biofluids. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2101508. [PMID: 34110682 DOI: 10.1002/smll.202101508] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 04/11/2021] [Indexed: 06/12/2023]
Abstract
Abnormal elevated levels of cytokines such as interferon (IFN), interleukin (IL), and tumor necrosis factor (TNF), are considered as one of the prognosis biomarkers for indicating the progression to severe or critical COVID-19. Hence, it is of great significance to develop devices for monitoring their levels in COVID-19 patients, and thus enabling detecting COVID-19 patients that are worsening and to treat them before they become critically ill. Here, an intelligent aptameric dual channel graphene-TWEEN 80 field effect transistor (DGTFET) biosensing device for on-site detection of IFN-γ, TNF-α, and IL-6 within 7 min with limits of detection (LODs) of 476 × 10-15 , 608 × 10-15 , or 611 × 10-15 m respectively in biofluids is presented. Using the customized Android App together with this intelligent device, asymptomatic or mild COVID-19 patients can have a preliminary self-detection of cytokines and get a warning reminder while the condition starts to deteriorate. Also, the device can be fabricated on flexible substrates toward wearable applications for moderate or even critical COVID-19 cases for consistently monitoring cytokines under different deformations. Hence, the intelligent aptameric DGTFET biosensing device is promising to be used for point-of-care applications for monitoring conditions of COVID-19 patients who are in different situations.
Collapse
Affiliation(s)
- Zhuang Hao
- State Key Laboratory of Robotics and Systems, School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, 150001, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, 150001, China
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Ministry of Education, Harbin Institute of Technology, Harbin, 150080, China
| | - Yang Luo
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, 110169, China
| | - Cong Huang
- State Key Laboratory of Robotics and Systems, School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, 150001, China
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Ministry of Education, Harbin Institute of Technology, Harbin, 150080, China
| | - Ziran Wang
- State Key Laboratory of Robotics and Systems, School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, 150001, China
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Ministry of Education, Harbin Institute of Technology, Harbin, 150080, China
| | - Guoli Song
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, 110169, China
| | - Yunlu Pan
- State Key Laboratory of Robotics and Systems, School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, 150001, China
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Ministry of Education, Harbin Institute of Technology, Harbin, 150080, China
| | - Xuezeng Zhao
- State Key Laboratory of Robotics and Systems, School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, 150001, China
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Ministry of Education, Harbin Institute of Technology, Harbin, 150080, China
| | - Shaoqin Liu
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, 150001, China
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Ministry of Education, Harbin Institute of Technology, Harbin, 150080, China
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, 150080, China
| |
Collapse
|
8
|
Using Aptamers as a Novel Method for Determining GnRH/LH Pulsatility. Int J Mol Sci 2020; 21:ijms21197394. [PMID: 33036411 PMCID: PMC7582658 DOI: 10.3390/ijms21197394] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 09/29/2020] [Accepted: 10/05/2020] [Indexed: 11/26/2022] Open
Abstract
Aptamers are a novel technology enabling the continuous measurement of analytes in blood and other body compartments, without the need for repeated sampling and the associated reagent costs of traditional antibody-based methodologies. Aptamers are short single-stranded synthetic RNA or DNA that recognise and bind to specific targets. The conformational changes that can occur upon aptamer–ligand binding are transformed into chemical, fluorescent, colour changes and other readouts. Aptamers have been developed to detect and measure a variety of targets in vitro and in vivo. Gonadotropin-releasing hormone (GnRH) is a pulsatile hypothalamic hormone that is essential for normal fertility but difficult to measure in the peripheral circulation. However, pulsatile GnRH release results in pulsatile luteinizing hormone (LH) release from the pituitary gland. As such, LH pulsatility is the clinical gold standard method to determine GnRH pulsatility in humans. Aptamers have recently been shown to successfully bind to and measure GnRH and LH, and this review will focus on this specific area. However, due to the adaptability of aptamers, and their suitability for incorporation into portable devices, aptamer-based technology is likely to be used more widely in the future.
Collapse
|
9
|
Hao Z, Pan Y, Huang C, Wang Z, Lin Q, Zhao X, Liu S. Modulating the Linker Immobilization Density on Aptameric Graphene Field Effect Transistors Using an Electric Field. ACS Sens 2020; 5:2503-2513. [PMID: 32375472 DOI: 10.1021/acssensors.0c00752] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Aptameric graphene-based field-effect transistors (A-GFETs) always employ linkers, which could immobilize on graphene through π-π stacking between contained pyrenyl groups and graphene, to anchor aptamers. Aptamer density is closely associated with the A-GFET sensitivity and determined by the linker density. Using known linker immobilization methods, the linker density is random, uncontrollable, and limited. In this work, we propose a novel linker immobilization method which can be used to effectively modulate the linker density using an electric field and further bridge the relationship between the linker density and the A-GFET sensitivity. Here, polar molecule 1-pyrenebutanoic acid succinimidyl ester (PASE) is used as a linker representative. In the electric field, PASE is arranged regularly with the electron-rich pyrenyl group forced toward graphene in the solution due to electrostatic repulsion, thereby making it possible to modulate the quantity of PASE molecules that could interact with graphene by tuning the electric field application and then realizing the regulation of the A-GFET sensitivity. Experimental results indicate that the limits of detection (LODs) of A-GFETs for detecting interleukin-6 (IL-6) and insulin can be significantly improved to be 618 and 766 fM, respectively, by applying an electric field at -0.3 V for 3 h during PASE immobilization.
Collapse
Affiliation(s)
- Zhuang Hao
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Harbin Institute of Technology, Ministry of Education, Harbin 150080, China
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001, China
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Yunlu Pan
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Harbin Institute of Technology, Ministry of Education, Harbin 150080, China
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, China
| | - Cong Huang
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Harbin Institute of Technology, Ministry of Education, Harbin 150080, China
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, China
| | - Ziran Wang
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Harbin Institute of Technology, Ministry of Education, Harbin 150080, China
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, China
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Xuezeng Zhao
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Harbin Institute of Technology, Ministry of Education, Harbin 150080, China
- School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001, China
| | - Shaoqin Liu
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Harbin Institute of Technology, Ministry of Education, Harbin 150080, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001, China
- School of Life Science and Technology, State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150080, China
| |
Collapse
|
10
|
Zhang X, Jing Q, Ao S, Schneider GF, Kireev D, Zhang Z, Fu W. Ultrasensitive Field-Effect Biosensors Enabled by the Unique Electronic Properties of Graphene. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1902820. [PMID: 31592577 DOI: 10.1002/smll.201902820] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 09/08/2019] [Indexed: 05/20/2023]
Abstract
This review provides a critical overview of current developments on nanoelectronic biochemical sensors based on graphene. Composed of a single layer of conjugated carbon atoms, graphene has outstanding high carrier mobility and low intrinsic electrical noise, but a chemically inert surface. Surface functionalization is therefore crucial to unravel graphene sensitivity and selectivity for the detection of targeted analytes. To achieve optimal performance of graphene transistors for biochemical sensing, the tuning of the graphene surface properties via surface functionalization and passivation is highlighted, as well as the tuning of its electrical operation by utilizing multifrequency ambipolar configuration and a high frequency measurement scheme to overcome the Debye screening to achieve low noise and highly sensitive detection. Potential applications and prospectives of ultrasensitive graphene electronic biochemical sensors ranging from environmental monitoring and food safety, healthcare and medical diagnosis, to life science research, are presented as well.
Collapse
Affiliation(s)
- Xiaoyan Zhang
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, P. R. China
- Leiden Institute of Chemistry, Leiden University, Einsteinweg 55, 2333CC, Leiden, The Netherlands
| | - Qiushi Jing
- School of Materials Science and Engineering, Tsinghua University, Shaw Technical Science Building, Haidian District, Beijing, 100084, P. R. China
| | - Shen Ao
- School of Materials Science and Engineering, Tsinghua University, Shaw Technical Science Building, Haidian District, Beijing, 100084, P. R. China
| | - Grégory F Schneider
- Leiden Institute of Chemistry, Leiden University, Einsteinweg 55, 2333CC, Leiden, The Netherlands
| | - Dmitry Kireev
- Department of Electrical and Computer Engineering, University of Texas at Austin, Austin, TX, 78757, USA
| | - Zhengjun Zhang
- School of Materials Science and Engineering, Tsinghua University, Shaw Technical Science Building, Haidian District, Beijing, 100084, P. R. China
| | - Wangyang Fu
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, P. R. China
| |
Collapse
|
11
|
Kumar N, Wang W, Ortiz-Marquez JC, Catalano M, Gray M, Biglari N, Hikari K, Ling X, Gao J, van Opijnen T, Burch KS. Dielectrophoresis assisted rapid, selective and single cell detection of antibiotic resistant bacteria with G-FETs. Biosens Bioelectron 2020; 156:112123. [PMID: 32174552 DOI: 10.1016/j.bios.2020.112123] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 02/07/2020] [Accepted: 02/21/2020] [Indexed: 01/19/2023]
Abstract
The rapid increase in antibiotic resistant pathogenic bacteria has become a global threat, which besides the development of new drugs, requires rapid, cheap, scalable, and accurate diagnostics. Label free biosensors relying on electrochemical, mechanical, and mass based detection of whole bacterial cells have attempted to meet these requirements. However, the trade-off between selectivity and sensitivity of such sensors remains a key challenge. In particular, point-of-care diagnostics that are able to reduce and/or prevent unneeded antibiotic prescriptions require highly specific probes with sensitive and accurate transducers that can be miniaturized and multiplexed, and that are easy to operate and cheap. Towards achieving this goal, we present a number of advances in the use of graphene field effect transistors (G-FET) including the first use of peptide probes to electrically detect antibiotic resistant bacteria in a highly specific manner. In addition, we dramatically reduce the needed concentration for detection by employing dielectrophoresis for the first time in a G-FET, allowing us to monitor changes in the Dirac point due to individual bacterial cells. Specifically, we realized rapid binding of bacterial cells to a G-FET by electrical field guiding to the device to realize an overall 3 orders of magnitude decrease in cell-concentration enabling a single-cell detection limit, and 9-fold reduction in needed time to 5 min. Utilizing our new biosensor and procedures, we demonstrate the first selective, electrical detection of the pathogenic bacterial species Staphylococcus aureus and antibiotic resistant Acinetobacter baumannii on a single platform.
Collapse
Affiliation(s)
- Narendra Kumar
- Department of Physics, Boston College, Chestnut Hill, MA, 02467, United States
| | - Wenjian Wang
- Department of Chemistry, Boston College, Chestnut Hill, MA, 02467, United States
| | | | - Matthew Catalano
- Department of Physics, Boston College, Chestnut Hill, MA, 02467, United States
| | - Mason Gray
- Department of Physics, Boston College, Chestnut Hill, MA, 02467, United States
| | - Nadia Biglari
- Department of Physics, Boston College, Chestnut Hill, MA, 02467, United States
| | - Kitadai Hikari
- Department of Chemistry, Boston University, Boston, MA, 02215, United States
| | - Xi Ling
- Department of Chemistry, Boston University, Boston, MA, 02215, United States; Division of Materials Science and Engineering, Boston University, Boston, MA, 02214, United States; The Photonics Center, Boston University, Boston, MA, 02214, United States
| | - Jianmin Gao
- Department of Chemistry, Boston College, Chestnut Hill, MA, 02467, United States.
| | - Tim van Opijnen
- Department of Biology, Boston College, Chestnut Hill, MA, 02467, United States.
| | - Kenneth S Burch
- Department of Physics, Boston College, Chestnut Hill, MA, 02467, United States.
| |
Collapse
|
12
|
Wang C, Wu J, He Y, Song Z, Shi S, Zhu Y, Jia Y, Ye W. Fully Solid-State Graphene Transistors with Striking Homogeneity and Sensitivity for the Practicalization of Single-Device Electronic Bioassays. NANO LETTERS 2020; 20:166-175. [PMID: 31815482 DOI: 10.1021/acs.nanolett.9b03528] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
To break through a critical barrier in the practical application of graphene biosensors, namely, device-to-device performance inhomogeneity, this work presents a novel scenario employing a fully solid-state (FSS) transistor configuration. Herein, the graphene sensing unit is completely encapsulated by a high-κ solid dielectric material, which isolates the sensing unit from solution contaminants and thus homogeneously maintains the extraordinary carrier mobility of pristine graphene in batch-made devices. To create an interface sensitive to biomolecular interactions based on the FSS configuration, a metallic floating gate functionalized by conductive mercapto-phenyl molecular linkers is defined on the top-layer solid dielectric. As the solid dielectric layer beneath the metal floating gate enables a higher capacitive gating efficiency than the regular graphene-solution electrical double layer (EDL) interface, the overall transistor amplification gain is further enhanced. As a proof of principle, a label-free DNAzymatic bioassay of Pb2+ is conducted. Without the traditional one-by-one device normalization, an excellent concentration detection limit of 929.8 fM is achieved, which is almost 2 orders of magnitude lower than that in existing works. The FSS configuration allows enhanced sensitivity and homogeneity, thereby providing new developmental guidelines for graphene biosensors beyond the laboratory investigation stage. Additionally, it has the potential to be universally applicable for cost-efficient single-device bioassays.
Collapse
Affiliation(s)
| | | | | | | | | | - Yibo Zhu
- Department of Mechanical Engineering , Columbia University , New York 10027 , United States
| | - Yuan Jia
- Jiangsu Key Laboratory of Micro-Nano Biomedical Instrument Design and Manufacture, School of Mechanical Engineering , Southeast University , Nanjing 211189 , China
| | - Weixiang Ye
- Jiangsu Key Laboratory of Thin Films, School of Physical Science and Technology , Soochow University , Suzhou 215006 , China
| |
Collapse
|
13
|
Lin Z, Wu G, Zhao L, Lai KWC. Carbon Nanomaterial-Based Biosensors: A Review of Design and Applications. IEEE NANOTECHNOLOGY MAGAZINE 2019. [DOI: 10.1109/mnano.2019.2927774] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
14
|
Balaban S, Durmus C, Aydindogan E, Gumus ZP, Timur S. An Electrochemical Biosensor Platform for Testing of Dehydroepiandrosterone 3‐Sulfate (DHEA−S) as a Model for Doping Materials. ELECTROANAL 2019. [DOI: 10.1002/elan.201900413] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Simge Balaban
- Department of Biochemistry, Faculty of Science DepartmentEge University 35100 Bornova, Izmir Turkey
| | - Ceren Durmus
- Department of Biochemistry, Faculty of Science DepartmentEge University 35100 Bornova, Izmir Turkey
| | - Eda Aydindogan
- Department of Biochemistry, Faculty of Science DepartmentEge University 35100 Bornova, Izmir Turkey
| | - Zinar Pinar Gumus
- Central Research Test and Analysis Laboratory Application and Research CenterEge University 35100 Bornova Izmir Turkey
| | - Suna Timur
- Department of Biochemistry, Faculty of Science DepartmentEge University 35100 Bornova, Izmir Turkey
- Central Research Test and Analysis Laboratory Application and Research CenterEge University 35100 Bornova Izmir Turkey
| |
Collapse
|
15
|
Wang X, Hao Z, Olsen TR, Zhang W, Lin Q. Measurements of aptamer-protein binding kinetics using graphene field-effect transistors. NANOSCALE 2019; 11:12573-12581. [PMID: 31219127 DOI: 10.1039/c9nr02797a] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Quantifying interactions between biomolecules subject to various environmental conditions is essential for applications such as drug discovery and precision medicine. This paper presents an investigation of the kinetics of environmentally dependent biomolecular binding using an electrolyte-gated graphene field-effect transistor (GFET) nanosensor. In this approach, biomolecular binding occurring on and in the vicinity of a graphene surface induces a change in carrier concentration, whose resulting conductance change is measured. This allows a systematic study of the kinetic properties of the binding system. We apply this approach to the specific binding of human immunoglobulin E (IgE), an antibody involved in parasite immunity, with an aptamer at different ionic strengths (Na+ and Mg2+) and temperatures. Experimental results demonstrate increased-rate binding kinetics at higher salt-ion concentrations and temperatures. In particular, the divalent cation Mg2+ yields more pronounced changes in the conformational structure of the aptamer than the monovalent cation Na+. In addition, the dissociation of the aptamer-protein complex at room temperature is found to be characterized by large unfavorable changes in the activation enthalpy and entropy.
Collapse
Affiliation(s)
- Xuejun Wang
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA. and State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, China
| | - Zhuang Hao
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
| | - Timothy R Olsen
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
| | - Wenjun Zhang
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, S7N 5A9, Canada
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
| |
Collapse
|
16
|
Hao Z, Pan Y, Shao W, Lin Q, Zhao X. Graphene-based fully integrated portable nanosensing system for on-line detection of cytokine biomarkers in saliva. Biosens Bioelectron 2019; 134:16-23. [PMID: 30952012 DOI: 10.1016/j.bios.2019.03.053] [Citation(s) in RCA: 74] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 03/13/2019] [Accepted: 03/26/2019] [Indexed: 01/07/2023]
Abstract
Saliva has been reported to contain various cytokine biomarkers which are associated with some severe diseases such as cancers. Non-invasive saliva diagnosis using wearable or portable devices may pave a new avenue for monitoring conditions of the high risk population. Here, a graphene-based fully integrated portable nanosensing system, the entire size of which is smaller than a smart-phone and can be handheld, is presented for on-line detection of cytokine biomarkers in saliva. This miniaturized system employs an aptameric graphene-based field effect transistor (GFET) using a buried-gate geometry with HfO2 as the dielectric layer and on-line signal processing circuits to realize the transduction and processing of signals which reflect cytokine concentrations. The signal can be wirelessly transmitted to a smart-phone or cloud sever through the Wi-Fi connection for visualizing the trend of the cytokine concentration change. Interleukin-6 (IL-6) is used as a representative to examine the sensing capability of the system. Experimental results demonstrate that the nanosensing system responds to the change of IL-6 concentration within 400s in saliva with a detection limit down to 12 pM. Therefore, this portable system offers the practicality to be potentially used for non-invasive saliva diagnosis of diseases at early stage.
Collapse
Affiliation(s)
- Zhuang Hao
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Ministry of Education and School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, 150010, China
| | - Yunlu Pan
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Ministry of Education and School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, 150010, China.
| | - Wenwen Shao
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Ministry of Education and School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, 150010, China
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, NY, 10027, USA
| | - Xuezeng Zhao
- Key Laboratory of Micro-systems and Micro-structures Manufacturing, Ministry of Education and School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, 150010, China
| |
Collapse
|
17
|
Affiliation(s)
- Bingbing Gao
- School of Pharmaceutical Sciences and School of Biotechnology and Pharmaceutical Engineering, Nanjing Tech University, Nanjing 211816, China
| | - Hong Liu
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Zhongze Gu
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| |
Collapse
|
18
|
Lima D, Inaba J, Clarindo Lopes L, Calaça GN, Los Weinert P, Lenzi Fogaça R, Ferreira de Moura J, Magalhães Alvarenga L, Cavalcante de Figueiredo B, Wohnrath K, Andrade Pessôa C. Label-free impedimetric immunosensor based on arginine-functionalized gold nanoparticles for detection of DHEAS, a biomarker of pediatric adrenocortical carcinoma. Biosens Bioelectron 2019; 133:86-93. [PMID: 30909017 DOI: 10.1016/j.bios.2019.02.063] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2019] [Accepted: 02/23/2019] [Indexed: 12/17/2022]
Abstract
Pediatric adrenocortical carcinoma (pACC) is a rare and aggressive malignancy of high occurrence in Southern Brazil. pACC is characterized by the usual overproduction of dehydroepiandrosterone sulfate (DHEAS), whose detection in serum or plasma can be effective to the early diagnosis of the disease. Therefore, the present paper reports, for the first time, the construction and application of a label-free impedimetric immunosensor to detect DHEAS, which was based on the modification of an oxidized glassy carbon electrode with arginine-functionalized gold nanoparticles (AuNPs-ARG) and anti-DHEA IgM antibodies (ox-GCE/AuNPs-ARG/IgM). AuNPs-ARG was synthesized by a green route, and characterized by UV-VIS spectroscopy, FTIR, TEM, DLS, and XRD. The construction of ox-GCE/AuNPs-ARG/IgM was optimized through factorial design and response surface methodology. Cyclic voltammetry and electrochemical impedance spectroscopy measurements were employed to characterize the optimized immunosensor. The DHEAS detection principle was based on the variation of charge transfer resistance (∆Rct) relative to the Fe(CN)64-/3- electrochemical probe after immunoassays in the presence of the biomarker. A linear relationship between ∆Rct and DHEAS concentration was verified in the range from 10.0 to 110.0 µg dL-1, with a LOD of 7.4 µg dL-1. Besides the good sensitivity, the immunosensor displayed accuracy, stability, and specificity to detect DHEAS. The promising analytical performance of ox-GCE/AuNPs-ARG/IgM was confirmed by quantifying DHEAS in real patient plasma samples, with results that were comparable to the reference chemiluminescence assay. Our results suggest that the presented immunosensor can find clinical applications in the early diagnosis of pACC and to monitor DHEAS levels in other adrenal pathologies.
Collapse
Affiliation(s)
- Dhésmon Lima
- Department of Chemistry, Universidade Estadual de Ponta Grossa, Av. General Carlos Cavalcanti, 4748, 84030-900 Ponta Grossa, Paraná, Brazil
| | - Juliana Inaba
- Department of Chemistry, Universidade Estadual de Ponta Grossa, Av. General Carlos Cavalcanti, 4748, 84030-900 Ponta Grossa, Paraná, Brazil
| | - Luma Clarindo Lopes
- Department of Chemistry, Universidade Estadual de Ponta Grossa, Av. General Carlos Cavalcanti, 4748, 84030-900 Ponta Grossa, Paraná, Brazil
| | - Giselle Nathaly Calaça
- Department of Chemistry, Instituto Federal do Paraná, Rodovia PR 323, KM 310, 87507-014 Umuarama, Paraná, Brazil
| | - Patrícia Los Weinert
- Department of Chemistry, Universidade Estadual de Ponta Grossa, Av. General Carlos Cavalcanti, 4748, 84030-900 Ponta Grossa, Paraná, Brazil
| | - Rafaela Lenzi Fogaça
- Department of Basic Pathology, Universidade Federal do Paraná, Av. Coronel Francisco H. dos Santos, 100, 81530-000 Curitiba, Paraná, Brazil
| | - Juliana Ferreira de Moura
- Department of Basic Pathology, Universidade Federal do Paraná, Av. Coronel Francisco H. dos Santos, 100, 81530-000 Curitiba, Paraná, Brazil
| | - Larissa Magalhães Alvarenga
- Department of Basic Pathology, Universidade Federal do Paraná, Av. Coronel Francisco H. dos Santos, 100, 81530-000 Curitiba, Paraná, Brazil
| | - Bonald Cavalcante de Figueiredo
- Department of Community Health, Universidade Federal do Paraná, Rua Padre Camargo, 261, 80069-240 Curitiba, Paraná, Brazil; Instituto de Pesquisa Pelé Pequeno Príncipe, Av. Silva Jardim, 1632, 80250-060 Curitiba, Paraná, Brazil
| | - Karen Wohnrath
- Department of Chemistry, Universidade Estadual de Ponta Grossa, Av. General Carlos Cavalcanti, 4748, 84030-900 Ponta Grossa, Paraná, Brazil
| | - Christiana Andrade Pessôa
- Department of Chemistry, Universidade Estadual de Ponta Grossa, Av. General Carlos Cavalcanti, 4748, 84030-900 Ponta Grossa, Paraná, Brazil.
| |
Collapse
|
19
|
Exploiting electrostatic shielding-effect of metal nanoparticles to recognize uncharged small molecule affinity with label-free graphene electronic biosensor. Biosens Bioelectron 2019; 129:93-99. [PMID: 30685707 DOI: 10.1016/j.bios.2018.12.051] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Revised: 12/10/2018] [Accepted: 12/28/2018] [Indexed: 11/21/2022]
Abstract
Label-free electronic biosensors as the non-electrochemical analytical tools without requirement of sophisticated instrumentation have become attractive, although their application in competitive affinity sensing of uncharged small molecules is still hindered by a difficulty in the development of competing analogues. To break through this bottleneck, we report a novel analogue made by epitope-modified metal nanoparticles to enable the electronic signaling of small-molecule analyte recognition via competitive affinity. While the electronic signaling capability of metal nanoparticle analogues is demonstrated by a graphene field-effect transistor bioassay of small-molecule glucose as a proof-of-principle, interestingly, we discover a new electronic signaling mechanism in the metal nanoparticle affinity, different to the intuitive charge accumulation expectation. On the basis of Kelvin-probe force microscopic potential characterization and theoretical discussion, we fundamentally elucidated the signaling mechanism as a seldom used electrostatic shielding-effect, that is, in the analogue-receptor affinity, metal nanoparticles with the charge density lower than receptor biomolecules can reduce the collective electrical potential via charge dispersion. Further consider the convenient epitope-modifiability of metal nanoparticles, the easy-to-develop analogues for diverse target analyte might potentially be predictable in the future. And the application of label-free electronic biosensors for the competitive affinity bioassay of range-extended small molecules may thus be promoted based on the electrostatic shielding-effect.
Collapse
|
20
|
Li Y, Zhu Y, Wang C, He M, Lin Q. Selective detection of water pollutants using a differential aptamer-based graphene biosensor. Biosens Bioelectron 2018; 126:59-67. [PMID: 30391910 DOI: 10.1016/j.bios.2018.10.047] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2018] [Revised: 10/19/2018] [Accepted: 10/22/2018] [Indexed: 12/11/2022]
Abstract
Graphene field-effect transistor (GFET) sensors are an attractive analytical tool for the detection of water pollutants. Unfortunately, this application has been hindered by the sensitivity of such sensors to nonspecific disturbances caused by variations of environmental conditions. Incorporation of differential designs is a logical choice to address this issue, but this has been difficult for GFET sensors due to the impact of fabrication processes and material properties. This paper presents a differential GFET affinity sensor for the selective detection of water pollutants in the presence of nonspecific disturbances. This differential design allows for minimization of the effects of variations of environmental conditions on the measurement accuracy. In addition, to mitigate the impact of the fabrication process and material property variations, we introduce a compensation scheme for the individual sensing units of the sensor, so that such variations are accounted for in the compensation-based differential sensing method. We test the use of this differential sensor for the selective detection of the water pollutant 17β-estradiol in buffer and tap water. Consistent detection results can be obtained with and without interferences of pH variations, and in tap water where unknown interferences are present. These results demonstrate that the differential graphene affinity sensor is capable of effectively mitigating the effects of nonspecific interferences to enable selective water pollutant detection for water quality monitoring.
Collapse
Affiliation(s)
- Yijun Li
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA; Center for Sensor Technology of Environment and Health, State Key Joint Laboratory of ESPC, School of Environment, Tsinghua University, Beijing 100084, China
| | - Yibo Zhu
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA
| | - Cheng Wang
- Center for Sensor Technology of Environment and Health, State Key Joint Laboratory of ESPC, School of Environment, Tsinghua University, Beijing 100084, China; College of Electronic and Communication Engineering, Tianjin Normal University, Tianjin 300387, China
| | - Miao He
- Center for Sensor Technology of Environment and Health, State Key Joint Laboratory of ESPC, School of Environment, Tsinghua University, Beijing 100084, China.
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
| |
Collapse
|
21
|
Qiu Y, Tang Y, Li B, He M. Rapid detection of cocaine using aptamer-based biosensor on an evanescent wave fibre platform. ROYAL SOCIETY OPEN SCIENCE 2018; 5:180821. [PMID: 30473831 PMCID: PMC6227954 DOI: 10.1098/rsos.180821] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Accepted: 09/13/2018] [Indexed: 05/11/2023]
Abstract
The rapid detection of cocaine has received considerable attention because of the instantaneous and adverse effects of cocaine overdose on human health. Aptamer-based biosensors for cocaine detection have been well established for research and application. However, reducing the analytic duration without deteriorating the sensitivity still remains as a challenge. Here, we proposed an aptamer-based evanescent wave fibre (EWF) biosensor to rapidly detect cocaine in a wide working range. At first, the aptamers were conjugated to complementary DNA with fluorescence tag and such conjugants were then immobilized on magnetic beads. After cocaine was introduced to compete against the aptamer-DNA conjugants, the released DNA in supernatant was detected on the EWF platform. The dynamic curves of EWF signals could be interpreted by the first-order kinetics and saturation model. The semi-log calibration curve covered a working range of 10-5000 µM of cocaine, and the limit of detection was approximately 10.5 µM. The duration of the full procedure was 990 s (16.5 min), and the detection interval was 390 s (6.5 min). The specified detection of cocaine was confirmed from four typical pharmaceutic agents. The analysis was repeated for 50 cycles without significant loss of sensitivity. Therefore, the aptamer-based EWF biosensor is a feasible solution to rapidly detect cocaine.
Collapse
Affiliation(s)
- Yong Qiu
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, People's Republic of China
| | - Yunfei Tang
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, People's Republic of China
- Ecological Environmental Protection Investments Company, China Communications Construction Corporation, Beijing 100013, People's Republic of China
| | - Bing Li
- School of Energy and Environmental Engineering, University of Beijing Science and Technology, Beijing 100083, People's Republic of China
| | - Miao He
- State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, People's Republic of China
| |
Collapse
|
22
|
Vlăsceanu GM, Amărandi RM, Ioniță M, Tite T, Iovu H, Pilan L, Burns JS. Versatile graphene biosensors for enhancing human cell therapy. Biosens Bioelectron 2018; 117:283-302. [DOI: 10.1016/j.bios.2018.04.053] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 04/18/2018] [Accepted: 04/25/2018] [Indexed: 01/04/2023]
|
23
|
Li X, Tang X, Chen X, Qu B, Lu L. Label-free and enzyme-free fluorescent isocarbophos aptasensor based on MWCNTs and G-quadruplex. Talanta 2018; 188:232-237. [DOI: 10.1016/j.talanta.2018.05.092] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 05/22/2018] [Accepted: 05/27/2018] [Indexed: 01/08/2023]
|
24
|
de Aquino BRH, Neek-Amal M, Milošević MV. Unconventional two-dimensional vibrations of a decorated carbon nanotube under electric field: linking actuation to advanced sensing ability. Sci Rep 2017; 7:13481. [PMID: 29044124 PMCID: PMC5647406 DOI: 10.1038/s41598-017-12647-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Accepted: 09/13/2017] [Indexed: 11/08/2022] Open
Abstract
We show that a carbon nanotube decorated with different types of charged metallic nanoparticles exhibits unusual two-dimensional vibrations when actuated by applied electric field. Such vibrations and diverse possible trajectories are not only fundamentally important but also have minimum two characteristic frequencies that can be directly linked back to the properties of the constituents in the considered nanoresonator. Namely, those frequencies and the maximal deflection during vibrations are very distinctively dependent on the geometry of the nanotube, the shape, element, mass and charge of the nanoparticle, and are vastly tunable by the applied electric field, revealing the unique sensing ability of devices made of molecular filaments and metallic nanoparticles.
Collapse
Affiliation(s)
- Belisa R H de Aquino
- Department of Physics, Universiteit Antwerpen, Groenenborgerlaan, 171, B-2020, Antwerpen, Belgium
| | - Mehdi Neek-Amal
- Department of Physics, Shahid Rajaee Teacher Training University, Lavizan, 16875-163, Tehran, Iran.
| | - Milorad V Milošević
- Department of Physics, Universiteit Antwerpen, Groenenborgerlaan, 171, B-2020, Antwerpen, Belgium.
| |
Collapse
|
25
|
Hao Z, Zhu Y, Wang X, Rotti PG, DiMarco C, Tyler SR, Zhao X, Engelhardt JF, Hone J, Lin Q. Real-Time Monitoring of Insulin Using a Graphene Field-Effect Transistor Aptameric Nanosensor. ACS APPLIED MATERIALS & INTERFACES 2017; 9:27504-27511. [PMID: 28770993 PMCID: PMC7875320 DOI: 10.1021/acsami.7b07684] [Citation(s) in RCA: 71] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
This paper presents an approach to the real-time, label-free, specific, and sensitive monitoring of insulin using a graphene aptameric nanosensor. The nanosensor is configured as a field-effect transistor, whose graphene-based conducting channel is functionalized with a guanine-rich IGA3 aptamer. The negatively charged aptamer folds into a compact and stable antiparallel or parallel G-quadruplex conformation upon binding with insulin, resulting in a change in the carrier density, and hence the electrical conductance, of the graphene. The change in the electrical conductance is then measured to enable the real-time monitoring of insulin levels. Testing has shown that the nanosensor offers an estimated limit of detection down to 35 pM and is functional in Krebs-Ringer bicarbonate buffer, a standard pancreatic islet perfusion medium. These results demonstrate the potential utility of this approach in label-free monitoring of insulin and in timely prediction of accurate insulin dosage in clinical diagnostics.
Collapse
Affiliation(s)
- Zhuang Hao
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
- Department of Mechanical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, China
| | - Yibo Zhu
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Xuejun Wang
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Pavana G. Rotti
- Department of Anatomy and Cell Biology, University of Iowa, Iowa City, Iowa 52242, United States
- Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242, United States
| | - Christopher DiMarco
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Scott R. Tyler
- Department of Anatomy and Cell Biology, University of Iowa, Iowa City, Iowa 52242, United States
| | - Xuezeng Zhao
- Department of Mechanical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang 150001, China
| | - John F. Engelhardt
- Department of Anatomy and Cell Biology, University of Iowa, Iowa City, Iowa 52242, United States
- Department of Biomedical Engineering, University of Iowa, Iowa City, Iowa 52242, United States
| | - James Hone
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, New York 10027, United States
- Corresponding Author:
| |
Collapse
|
26
|
Li Y, Wang C, Zhu Y, Zhou X, Xiang Y, He M, Zeng S. Fully integrated graphene electronic biosensor for label-free detection of lead (II) ion based on G-quadruplex structure-switching. Biosens Bioelectron 2017; 89:758-763. [DOI: 10.1016/j.bios.2016.10.061] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2016] [Revised: 10/17/2016] [Accepted: 10/20/2016] [Indexed: 11/28/2022]
|
27
|
Pesl M, Pribyl J, Caluori G, Cmiel V, Acimovic I, Jelinkova S, Dvorak P, Starek Z, Skladal P, Rotrekl V. Phenotypic assays for analyses of pluripotent stem cell-derived cardiomyocytes. J Mol Recognit 2016; 30. [PMID: 27995655 DOI: 10.1002/jmr.2602] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Revised: 11/04/2016] [Accepted: 11/13/2016] [Indexed: 12/27/2022]
Abstract
Stem cell-derived cardiomyocytes (CMs) hold great hopes for myocardium regeneration because of their ability to produce functional cardiac cells in large quantities. They also hold promise in dissecting the molecular principles involved in heart diseases and also in drug development, owing to their ability to model the diseases using patient-specific human pluripotent stem cell (hPSC)-derived CMs. The CM properties essential for the desired applications are frequently evaluated through morphologic and genotypic screenings. Even though these characterizations are necessary, they cannot in principle guarantee the CM functionality and their drug response. The CM functional characteristics can be quantified by phenotype assays, including electrophysiological, optical, and/or mechanical approaches implemented in the past decades, especially when used to investigate responses of the CMs to known stimuli (eg, adrenergic stimulation). Such methods can be used to indirectly determine the electrochemomechanics of the cardiac excitation-contraction coupling, which determines important functional properties of the hPSC-derived CMs, such as their differentiation efficacy, their maturation level, and their functionality. In this work, we aim to systematically review the techniques and methodologies implemented in the phenotype characterization of hPSC-derived CMs. Further, we introduce a novel approach combining atomic force microscopy, fluorescent microscopy, and external electrophysiology through microelectrode arrays. We demonstrate that this novel method can be used to gain unique information on the complex excitation-contraction coupling dynamics of the hPSC-derived CMs.
Collapse
Affiliation(s)
- Martin Pesl
- Department of Biology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
- ICRC, St. Anne's University Hospital, Brno, Czech Republic
| | - Jan Pribyl
- CEITEC, Masaryk University, Brno, Czech Republic
| | - Guido Caluori
- ICRC, St. Anne's University Hospital, Brno, Czech Republic
- CEITEC, Masaryk University, Brno, Czech Republic
| | - Vratislav Cmiel
- Department of Biomedical Engineering, Faculty of Electrical Engineering and Communication, Brno University of Technology, Brno, Czech Republic
| | - Ivana Acimovic
- Department of Biology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Sarka Jelinkova
- Department of Biology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Petr Dvorak
- Department of Biology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
- ICRC, St. Anne's University Hospital, Brno, Czech Republic
| | - Zdenek Starek
- ICRC, St. Anne's University Hospital, Brno, Czech Republic
| | - Petr Skladal
- CEITEC, Masaryk University, Brno, Czech Republic
- Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Vladimir Rotrekl
- Department of Biology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
- ICRC, St. Anne's University Hospital, Brno, Czech Republic
| |
Collapse
|
28
|
Du P, Jin M, Chen G, Zhang C, Jiang Z, Zhang Y, Zou P, She Y, Jin F, Shao H, Wang S, Zheng L, Wang J. A Competitive Bio-Barcode Amplification Immunoassay for Small Molecules Based on Nanoparticles. Sci Rep 2016. [PMID: 27924952 DOI: 10.1038/srep3811] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/15/2023] Open
Abstract
A novel detection method of small molecules, competitive bio-barcode amplification immunoassay, was developed and described in this report. Through the gold nanoparticles (AuNPs) probe and magnetic nanoparticles (MNPs) probe we prepared, only one monoclonal antibody can be used to detect small molecules. The competitive bio-barcode amplification immunoassay overcomes the obstacle that the bio-barcode assay cannot be used in small molecular detection, as two antibodies are unable to combine to one small molecule due to its small molecular structure. The small molecular compounds, triazophos, were selected as targets for the competitive bio-barcode amplification immunoassay. The linear range of detection was from 0.04 ng mL-1 to 10 ng mL-1, and the limit of detection (LOD) was 0.02 ng mL-1, which was 10-20 folds lower than ELISA (Enzyme Linked Immunosorbent Assay). A practical application of the proposed immunoassay was evaluated by detecting triazophos in real samples. The recovery rate ranged from 72.5% to 110.5%, and the RSD was less than 20%. These results were validated by GC-MS, which indicated that this convenient and sensitive method has great potential for small molecular in real samples.
Collapse
Affiliation(s)
- Pengfei Du
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Maojun Jin
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Ge Chen
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Chan Zhang
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Zejun Jiang
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Yanxin Zhang
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Pan Zou
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Yongxin She
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Fen Jin
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Hua Shao
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Shanshan Wang
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Lufei Zheng
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Jing Wang
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| |
Collapse
|
29
|
Du P, Jin M, Chen G, Zhang C, Jiang Z, Zhang Y, Zou P, She Y, Jin F, Shao H, Wang S, Zheng L, Wang J. A Competitive Bio-Barcode Amplification Immunoassay for Small Molecules Based on Nanoparticles. Sci Rep 2016; 6:38114. [PMID: 27924952 PMCID: PMC5141433 DOI: 10.1038/srep38114] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Accepted: 11/04/2016] [Indexed: 12/17/2022] Open
Abstract
A novel detection method of small molecules, competitive bio-barcode amplification immunoassay, was developed and described in this report. Through the gold nanoparticles (AuNPs) probe and magnetic nanoparticles (MNPs) probe we prepared, only one monoclonal antibody can be used to detect small molecules. The competitive bio-barcode amplification immunoassay overcomes the obstacle that the bio-barcode assay cannot be used in small molecular detection, as two antibodies are unable to combine to one small molecule due to its small molecular structure. The small molecular compounds, triazophos, were selected as targets for the competitive bio-barcode amplification immunoassay. The linear range of detection was from 0.04 ng mL−1 to 10 ng mL−1, and the limit of detection (LOD) was 0.02 ng mL−1, which was 10–20 folds lower than ELISA (Enzyme Linked Immunosorbent Assay). A practical application of the proposed immunoassay was evaluated by detecting triazophos in real samples. The recovery rate ranged from 72.5% to 110.5%, and the RSD was less than 20%. These results were validated by GC-MS, which indicated that this convenient and sensitive method has great potential for small molecular in real samples.
Collapse
Affiliation(s)
- Pengfei Du
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Maojun Jin
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Ge Chen
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Chan Zhang
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Zejun Jiang
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Yanxin Zhang
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Pan Zou
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Yongxin She
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Fen Jin
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Hua Shao
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Shanshan Wang
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Lufei Zheng
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Jing Wang
- Key Laboratory for Agro-Products Quality and Food Safety, Institute of Quality Standards &Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| |
Collapse
|
30
|
|
31
|
Pesl M, Pribyl J, Acimovic I, Vilotic A, Jelinkova S, Salykin A, Lacampagne A, Dvorak P, Meli AC, Skladal P, Rotrekl V. Atomic force microscopy combined with human pluripotent stem cell derived cardiomyocytes for biomechanical sensing. Biosens Bioelectron 2016; 85:751-757. [DOI: 10.1016/j.bios.2016.05.073] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 05/11/2016] [Accepted: 05/23/2016] [Indexed: 11/16/2022]
|
32
|
|
33
|
Affiliation(s)
- Bingbing Gao
- State Key Laboratory of Bioelectronics,
School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Hong Liu
- State Key Laboratory of Bioelectronics,
School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Zhongze Gu
- State Key Laboratory of Bioelectronics,
School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| |
Collapse
|
34
|
Zhu Y, Hao Y, Adogla EA, Yan J, Li D, Xu K, Wang Q, Hone J, Lin Q. A graphene-based affinity nanosensor for detection of low-charge and low-molecular-weight molecules. NANOSCALE 2016; 8:5815-9. [PMID: 26912374 PMCID: PMC4791181 DOI: 10.1039/c5nr08866f] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
This paper presents a graphene nanosensor for affinity-based detection of low-charge, low-molecular-weight molecules, using glucose as a representative. The sensor is capable of measuring glucose concentration in a practically relevant range of 2 μM to 25 mM, and can potentially be used in noninvasive glucose monitoring.
Collapse
Affiliation(s)
- Yibo Zhu
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
| | - Yufeng Hao
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
| | - Enoch A Adogla
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208, USA
| | - Jing Yan
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208, USA
| | - Dachao Li
- College of Precision Instrument and Opto-Electronic Engineering, Tianjin University, Tianjin, 300072, China
| | - Kexin Xu
- College of Precision Instrument and Opto-Electronic Engineering, Tianjin University, Tianjin, 300072, China
| | - Qian Wang
- Department of Chemistry and Biochemistry, University of South Carolina, Columbia, SC 29208, USA
| | - James Hone
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
| | - Qiao Lin
- Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.
| |
Collapse
|
35
|
Li C, Meng Y, Wang S, Qian M, Wang J, Lu W, Huang R. Mesoporous Carbon Nanospheres Featured Fluorescent Aptasensor for Multiple Diagnosis of Cancer in Vitro and in Vivo. ACS NANO 2015; 9:12096-103. [PMID: 26575351 DOI: 10.1021/acsnano.5b05137] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Multiple diagnosis of cancer by a facile fluorescent sensor is extremely attractive. Herein, a Cy3-labeled ssDNA probe (P0-Cy3) was π-π stacked on the surface of oxidized mesoporous carbon nanospheres (OMCN) to construct the fluorescent "turn-on" aptasensor. Attributing to the intrinsic properties of OMCN, the OMCN-based aptasensor not only can be used to detect mucin1 protein in liquid with a wide range of 0.1-10.6 μmol/L, a low detection limit of 6.52 nmol/L, and good selectivity, but also can quantify the cancer cells in solution with the linear range of 10(4)-2 × 10(6) cells/mL and a detection limit of 8500 cells/mL. Fascinatingly, this OMCN-based aptasensor was exploited to image cancer via solid tissues such as cells, tissue sections, and ex vivo and in vivo tumors, in which the obvious distinguishability between cancer and normal tissues was clearly demonstrated. This is a robust and simple detection technique, which can well achieve the multiple diagnosis of cancer in vitro and in vivo.
Collapse
Affiliation(s)
- Chengyi Li
- Department of Pharmaceutics, School of Pharmacy, Key Laboraty of Smart Drug Delivery, Ministry of Education, Fudan University , Shanghai 201203, China
| | - Ying Meng
- Department of Pharmaceutics, School of Pharmacy, Key Laboraty of Smart Drug Delivery, Ministry of Education, Fudan University , Shanghai 201203, China
| | - Shanshan Wang
- Department of Pharmaceutics, School of Pharmacy, Key Laboraty of Smart Drug Delivery, Ministry of Education, Fudan University , Shanghai 201203, China
| | - Min Qian
- Department of Pharmaceutics, School of Pharmacy, Key Laboraty of Smart Drug Delivery, Ministry of Education, Fudan University , Shanghai 201203, China
| | - Jianxin Wang
- Department of Pharmaceutics, School of Pharmacy, Key Laboraty of Smart Drug Delivery, Ministry of Education, Fudan University , Shanghai 201203, China
| | - Weiyue Lu
- Department of Pharmaceutics, School of Pharmacy, Key Laboraty of Smart Drug Delivery, Ministry of Education, Fudan University , Shanghai 201203, China
| | - Rongqin Huang
- Department of Pharmaceutics, School of Pharmacy, Key Laboraty of Smart Drug Delivery, Ministry of Education, Fudan University , Shanghai 201203, China
| |
Collapse
|
36
|
Wu A, Wang Q, Zhu Q, Ni J, Gao F. A facile and highly sensitive impedimetric DNA biosensor with ultralow background response based on in situ reduced graphene oxide. RSC Adv 2015. [DOI: 10.1039/c5ra16233e] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
A facile and highly sensitive impedimetric DNA biosensor with ultralow background response based on in situ reduced graphene oxide.
Collapse
Affiliation(s)
- Aiqun Wu
- Department of Chemistry and Environment Science
- Fujian Province University Key Laboratory of Analytical Science Minnan Normal University
- Zhangzhou
- P. R. China
| | - Qingxiang Wang
- Department of Chemistry and Environment Science
- Fujian Province University Key Laboratory of Analytical Science Minnan Normal University
- Zhangzhou
- P. R. China
| | - Qionghua Zhu
- Department of Chemistry and Environment Science
- Fujian Province University Key Laboratory of Analytical Science Minnan Normal University
- Zhangzhou
- P. R. China
| | - Jiancong Ni
- Department of Chemistry and Environment Science
- Fujian Province University Key Laboratory of Analytical Science Minnan Normal University
- Zhangzhou
- P. R. China
| | - Feng Gao
- Department of Chemistry and Environment Science
- Fujian Province University Key Laboratory of Analytical Science Minnan Normal University
- Zhangzhou
- P. R. China
| |
Collapse
|