1
|
Li W, Yang X, Wang D, Xie J, Wang S, Rong Z. A handheld fluorescent lateral flow immunoassay platform for highly sensitive point-of-care detection of methamphetamine and tramadol. Talanta 2024; 277:126438. [PMID: 38897012 DOI: 10.1016/j.talanta.2024.126438] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 05/23/2024] [Accepted: 06/14/2024] [Indexed: 06/21/2024]
Abstract
The escalating issue of drug abuse poses a significant threat to public health and societal stability worldwide. An on-site drug detection platform is vital for combating drug abuse and trafficking, as it eliminates the need for additional tools, extensive processes, or specialized training. Therefore, it is imperative to develop a fast, sensitive, non-invasive, and reliable multiplex drug testing platform. In this study, we have presented a silica core@dual quantum dot-shell nanocomposite (SI/DQD)-based fluorescent lateral flow immunoassay (LFIA) platform for the highly sensitive and simultaneous point-of-care (POC) detection of methamphetamine (MET) and tramadol (TR). A 3D-printed attachment was designed to integrate optical and electrical components, facilitating the miniaturization of the instrument and reducing both cost and complexity. The device's advanced hardware and effective fluorescence extraction algorithm with waveform reconstruction enable swift, automatic noise reduction and data analysis. SI/DQD nanocomposites were utilized as fluorescent nanotags in the LFIA strips due to their outstanding luminous efficiency and robustness. This LFIA platform achieves impressive detection limits (LODs) of 0.11 ng mL-1 for MET and 0.017 ng mL-1 for TR. The method has also successfully detected MET and TR in complex biological samples, demonstrating its practical application capabilities. The proposed fluorescent LFIA platform, based on SI/DQD technology, holds significant promise for the swift and accurate POC detection of these substances. Its affordability, compact size, and excellent analytical performance make it suitable for on-site drug testing, including at borders and roadside checks, and open up new possibilities for the design and implementation of drug testing methods.
Collapse
Affiliation(s)
- Weijia Li
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Toxicology and Pharmacology, Beijing, 100850, China
| | | | - Dongfeng Wang
- Bioinformatics Center of AMMS, Beijing, 100850, China
| | - Jianwei Xie
- State Key Laboratory of Toxicology and Medical Countermeasures, and Laboratory of Toxicant Analysis, Institute of Toxicology and Pharmacology, Beijing, 100850, China.
| | - Shengqi Wang
- Bioinformatics Center of AMMS, Beijing, 100850, China.
| | - Zhen Rong
- Bioinformatics Center of AMMS, Beijing, 100850, China.
| |
Collapse
|
2
|
Chang W, Zheng Z, Ma Y, Du Y, Shi X, Wang C. An electrochemical aptasensor for methylamphetamine rapid detection by single-on mode based on competition with complementary DNA. Sci Rep 2024; 14:9279. [PMID: 38654039 DOI: 10.1038/s41598-024-59505-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 04/11/2024] [Indexed: 04/25/2024] Open
Abstract
A simple and rapid electrochemical sensing method with high sensitivity and specificity of aptamers was developed for the detection of methylamphetamine (MAMP). A short anti-MAMP thiolated aptamer (Apt) with a methylene blue (MB) probe at 3'-end was immobilized on the surface of a gold electrode (MB-Apt-S/GE). The electrochemical signal appeared when MAMP presenting in the sample solution competed with cDNA for binding with MB-Apt-S. Under optimized conditions, the liner range of this signal-on electrochemical aptasensor for the detection of MAMP achieved from 1.0 to 10.0 nmol/L and 10.0-400 nmol/L. LOD 0.88 nmol/L were obtained. Satisfactory spiked recoveries of saliva and urine were also obtained. In this method, only 5 min were needed to incubate before the square wave voltammetry (SWV) analysis, which was much more rapid than other electrochemical sensors, leading to a bright and broad prospect for the detection of MAMP in biological sample. This method can be used for on-site rapid detection on special occasions, such as drug driving scenes, entertainment venues suspected of drug use, etc.
Collapse
Affiliation(s)
- Wenzhuo Chang
- Key Laboratory of Evidence Science Techniques Research and Application of Gansu Province, Gansu University of Political Science and Law, Lanzhou, 730070, China
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China
| | - Zhixiang Zheng
- Key Laboratory of Evidence Science Techniques Research and Application of Gansu Province, Gansu University of Political Science and Law, Lanzhou, 730070, China.
| | - Yongjun Ma
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, 730070, China.
| | - Yongling Du
- College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China
| | - Xuezhao Shi
- College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China
| | - Chunming Wang
- College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China
| |
Collapse
|
3
|
Rosendo LM, Antunes M, Simão AY, Brinca AT, Catarro G, Pelixo R, Martinho J, Pires B, Soares S, Cascalheira JF, Passarinha L, Rosado T, Barroso M, Gallardo E. Sensors in the Detection of Abused Substances in Forensic Contexts: A Comprehensive Review. MICROMACHINES 2023; 14:2249. [PMID: 38138418 PMCID: PMC10745465 DOI: 10.3390/mi14122249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Revised: 12/10/2023] [Accepted: 12/13/2023] [Indexed: 12/24/2023]
Abstract
Forensic toxicology plays a pivotal role in elucidating the presence of drugs of abuse in both biological and solid samples, thereby aiding criminal investigations and public health initiatives. This review article explores the significance of sensor technologies in this field, focusing on diverse applications and their impact on the determination of drug abuse markers. This manuscript intends to review the transformative role of portable sensor technologies in detecting drugs of abuse in various samples. They offer precise, efficient, and real-time detection capabilities in both biological samples and solid substances. These sensors have become indispensable tools, with particular applications in various scenarios, including traffic stops, crime scenes, and workplace drug testing. The integration of portable sensor technologies in forensic toxicology is a remarkable advancement in the field. It has not only improved the speed and accuracy of drug abuse detection but has also extended the reach of forensic toxicology, making it more accessible and versatile. These advancements continue to shape forensic toxicology, ensuring swift, precise, and reliable results in criminal investigations and public health endeavours.
Collapse
Affiliation(s)
- Luana M. Rosendo
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Mónica Antunes
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Ana Y. Simão
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Ana Teresa Brinca
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Gonçalo Catarro
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Rodrigo Pelixo
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - João Martinho
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Bruno Pires
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - Sofia Soares
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
| | - José Francisco Cascalheira
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Departamento de Química, Universidade da Beira Interior, 6200-001 Covilhã, Portugal
| | - Luís Passarinha
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
- Associate Laboratory i4HB-Institute for Health and Bioeconomy, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2819-516 Caparica, Portugal
- UCIBIO-Applied Molecular Biosciences Unit, Chemistry Department, NOVA School of Science and Technology, 2829-516 Caparica, Portugal
| | - Tiago Rosado
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
- Centro Académico Clínico das Beiras (CACB)—Grupo de Problemas Relacionados com Toxicofilias, 6200-000 Covilhã, Portugal
| | - Mário Barroso
- Serviço de Química e Toxicologia Forenses, Instituto de Medicina Legal e Ciências Forenses—Delegação do Sul, 1169-201 Lisboa, Portugal
| | - Eugenia Gallardo
- Centro de Investigação em Ciências da Saúde, Universidade da Beira Interior (CICS-UBI), 6200-506 Covilhã, Portugal; (L.M.R.); (M.A.); (A.Y.S.); (A.T.B.); (G.C.); (R.P.); (J.M.); (B.P.); (S.S.); (J.F.C.); (L.P.); (T.R.)
- Laboratório de Fármaco-Toxicologia, UBIMedical, Universidade da Beira Interior, EM506, 6200-000 Covilhã, Portugal
- Centro Académico Clínico das Beiras (CACB)—Grupo de Problemas Relacionados com Toxicofilias, 6200-000 Covilhã, Portugal
| |
Collapse
|
4
|
Truta F, Drăgan AM, Tertis M, Parrilla M, Slosse A, Van Durme F, de Wael K, Cristea C. Electrochemical Rapid Detection of Methamphetamine from Confiscated Samples Using a Graphene-Based Printed Platform. SENSORS (BASEL, SWITZERLAND) 2023; 23:6193. [PMID: 37448052 DOI: 10.3390/s23136193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 06/29/2023] [Accepted: 07/04/2023] [Indexed: 07/15/2023]
Abstract
Methamphetamine (MAP) is a highly addictive and illegal stimulant drug that has a significant impact on the central nervous system. Its detection in biological and street samples is crucial for various organizations involved in forensic medicine, anti-drug efforts, and clinical diagnosis. In recent years, nanotechnology and nanomaterials have played a significant role in the development of analytical sensors for MAP detection. In this study, a fast, simple, and cost-effective electrochemical sensor is presented that is used for the sensitive detection of MAP in confiscated street samples with a complex matrix. The optimized screen-printed sensor based on a carbon working electrode modified with graphene demonstrated an excellent limit of detection, good sensitivity, and a wide dynamic range (1-500 μM) for the target illicit drug both for standard solutions and real samples (seized samples, tap water, and wastewater samples). It can detect MAP at concentrations as low as 300 nM in real samples. This limit of detection is suitable for the rapid preliminary screening of suspicious samples in customs, ports, airports, and on the street. Furthermore, the sensor exhibits a good recovery rate, indicating its reliability and repeatability. This quality is crucial for ensuring consistent and accurate results during screening processes.
Collapse
Affiliation(s)
- Florina Truta
- Department of Analytical Chemistry, Iuliu Hațieganu University of Medicine and Pharmacy, 8 Victor Babes, 400012 Cluj-Napoca, Romania
| | - Ana-Maria Drăgan
- Department of Analytical Chemistry, Iuliu Hațieganu University of Medicine and Pharmacy, 8 Victor Babes, 400012 Cluj-Napoca, Romania
- A-Sense Lab, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
| | - Mihaela Tertis
- Department of Analytical Chemistry, Iuliu Hațieganu University of Medicine and Pharmacy, 8 Victor Babes, 400012 Cluj-Napoca, Romania
| | - Marc Parrilla
- A-Sense Lab, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
| | - Amorn Slosse
- National Institute for Criminalistics and Criminology (NICC), Vilvoordsesteenweg 100, 1120 Brussels, Belgium
| | - Filip Van Durme
- National Institute for Criminalistics and Criminology (NICC), Vilvoordsesteenweg 100, 1120 Brussels, Belgium
| | - Karolien de Wael
- A-Sense Lab, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
- NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010 Antwerp, Belgium
| | - Cecilia Cristea
- Department of Analytical Chemistry, Iuliu Hațieganu University of Medicine and Pharmacy, 8 Victor Babes, 400012 Cluj-Napoca, Romania
| |
Collapse
|
5
|
Dragan AM, Parrilla M, Sleegers N, Slosse A, Van Durme F, van Nuijs A, Oprean R, Cristea C, De Wael K. Investigating the electrochemical profile of methamphetamine to enable fast on-site detection in forensic analysis. Talanta 2023; 255:124208. [PMID: 36628903 DOI: 10.1016/j.talanta.2022.124208] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 12/12/2022] [Accepted: 12/19/2022] [Indexed: 01/06/2023]
Abstract
Methamphetamine (MA) is a synthetic psychoactive drug which is consumed both licitly and illicitly. In some countries it is prescribed for attention-deficit and hyperactivity disorder, and short-term treatment of obesity. More often though, it is abused for its psychostimulant properties. Unfortunately, the spread and abuse of this synthetic drug have increased globally, being reported as the most widely consumed synthetic psychoactive drug in the world in 2019. Attempting to overcome the shortcomings of the currently used on-site methods for MA detection in suspected cargos, the present study explores the potential of electrochemical identification of MA by means of square wave voltammetry on disposable graphite screen-printed electrodes. Hence, the analytical characterization of the method was evaluated under optimal conditions exhibiting a linear range between 50 μM and 2.5 mM MA, a LOD of 16.7 μM, a LOQ of 50.0 μM and a sensitivity of 5.3 μA mM-1. Interestingly, two zones in the potential window were identified for the detection of MA, depending on its concentration in solution. Furthermore, the oxidative pathway of MA was elucidated employing liquid chromatography - mass spectrometry to understand the change in the electrochemical profile. Thereafter, the selectivity of the method towards MA in mixtures with other drugs of abuse as well as common adulterants/cutting agents was evaluated. Finally, the described method was employed for the analysis of MA in confiscated samples and compared with forensic methods, displaying its potential as a fast and easy-to-use method for on-site analysis.
Collapse
Affiliation(s)
- Ana-Maria Dragan
- Department of Analytical Chemistry, Faculty of Pharmacy, 'Iuliu Hațieganu' University of Medicine and Pharmacy Cluj-Napoca, Pasteur 6, 400349, Cluj-Napoca, Romania; A-Sense Lab, University of Antwerp, Groenenborgerlaan 171, 2010, Antwerp, Belgium
| | - Marc Parrilla
- A-Sense Lab, University of Antwerp, Groenenborgerlaan 171, 2010, Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010, Antwerp, Belgium
| | - Nick Sleegers
- A-Sense Lab, University of Antwerp, Groenenborgerlaan 171, 2010, Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010, Antwerp, Belgium
| | - Amorn Slosse
- Drugs and Toxicology Department, National Institute for Criminalistics and Criminology (NICC), Vilvoordsesteenweg 100, 1120, Brussels, Belgium
| | - Filip Van Durme
- Drugs and Toxicology Department, National Institute for Criminalistics and Criminology (NICC), Vilvoordsesteenweg 100, 1120, Brussels, Belgium
| | - Alexander van Nuijs
- Toxicological Center, University of Antwerp, Universiteitsplein 1, 2610, Antwerp, Belgium
| | - Radu Oprean
- Department of Analytical Chemistry, Faculty of Pharmacy, 'Iuliu Hațieganu' University of Medicine and Pharmacy Cluj-Napoca, Pasteur 6, 400349, Cluj-Napoca, Romania
| | - Cecilia Cristea
- Department of Analytical Chemistry, Faculty of Pharmacy, 'Iuliu Hațieganu' University of Medicine and Pharmacy Cluj-Napoca, Pasteur 6, 400349, Cluj-Napoca, Romania
| | - Karolien De Wael
- A-Sense Lab, University of Antwerp, Groenenborgerlaan 171, 2010, Antwerp, Belgium; NANOlab Center of Excellence, University of Antwerp, Groenenborgerlaan 171, 2010, Antwerp, Belgium.
| |
Collapse
|
6
|
Biosensor integrated brain-on-a-chip platforms: Progress and prospects in clinical translation. Biosens Bioelectron 2023; 225:115100. [PMID: 36709589 DOI: 10.1016/j.bios.2023.115100] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Revised: 01/07/2023] [Accepted: 01/22/2023] [Indexed: 01/26/2023]
Abstract
Because of the brain's complexity, developing effective treatments for neurological disorders is a formidable challenge. Research efforts to this end are advancing as in vitro systems have reached the point that they can imitate critical components of the brain's structure and function. Brain-on-a-chip (BoC) was first used for microfluidics-based systems with small synthetic tissues but has expanded recently to include in vitro simulation of the central nervous system (CNS). Defining the system's qualifying parameters may improve the BoC for the next generation of in vitro platforms. These parameters show how well a given platform solves the problems unique to in vitro CNS modeling (like recreating the brain's microenvironment and including essential parts like the blood-brain barrier (BBB)) and how much more value it offers than traditional cell culture systems. This review provides an overview of the practical concerns of creating and deploying BoC systems and elaborates on how these technologies might be used. Not only how advanced biosensing technologies could be integrated with BoC system but also how novel approaches will automate assays and improve point-of-care (PoC) diagnostics and accurate quantitative analyses are discussed. Key challenges providing opportunities for clinical translation of BoC in neurodegenerative disorders are also addressed.
Collapse
|
7
|
Dai Z. Recent Advances in the Development of Portable Electrochemical Sensors for Controlled Substances. SENSORS (BASEL, SWITZERLAND) 2023; 23:3140. [PMID: 36991851 PMCID: PMC10058808 DOI: 10.3390/s23063140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/09/2023] [Accepted: 03/10/2023] [Indexed: 06/19/2023]
Abstract
This review article summarizes recent achievements in developing portable electrochemical sensing systems for the detection and/or quantification of controlled substances with potential on-site applications at the crime scene or other venues and in wastewater-based epidemiology. Electrochemical sensors employing carbon screen-printed electrodes (SPEs), including a wearable glove-based one, and aptamer-based devices, including a miniaturized aptamer-based graphene field effect transistor platform, are some exciting examples. Quite straightforward electrochemical sensing systems and methods for controlled substances have been developed using commercially available carbon SPEs and commercially available miniaturized potentiostats. They offer simplicity, ready availability, and affordability. With further development, they might become ready for deployment in forensic field investigation, especially when fast and informed decisions are to be made. Slightly modified carbon SPEs or SPE-like devices might be able to offer higher specificity and sensitivity while they can still be used on commercially available miniaturized potentiostats or lab-fabricated portable or even wearable devices. Affinity-based portable devices employing aptamers, antibodies, and molecularly imprinted polymers have been developed for more specific and sensitive detection and quantification. With further development of both hardware and software, the future of electrochemical sensors for controlled substances is bright.
Collapse
Affiliation(s)
- Zhaohua Dai
- Forensic Science Program, Department of Chemistry and Physical Sciences, Pace University, New York, NY 10038, USA
| |
Collapse
|
8
|
Silva-Neto HA, Duarte-Junior GF, Rocha DS, Bedioui F, Varenne A, Coltro WKT. Recycling 3D Printed Residues for the Development of Disposable Paper-Based Electrochemical Sensors. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 36884339 DOI: 10.1021/acsami.3c00370] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Here, we propose a recyclable approach using acrylonitrile-butadiene-styrene (ABS) residues from additive manufacturing in combination with low-cost and accessible graphite flakes as a novel and potential mixture for creating a conductive paste. The graphite particles were successfully incorporated in the recycled thermoplastic composite when solubilized with acetone and the mixture demonstrated greater adherence to different substrates, among which cellulose-based material made possible the construction of a paper-based electrochemical sensor (PES). The morphological, structural, and electrochemical characterizations of the recycled electrode material were demonstrated to be similar to those of the traditional carbon-based surfaces. Faradaic responses based on redox probe activity ([Fe(CN)6]3-/4-) exhibited well-defined peak currents and diffusional mass transfer as a quasi-reversible system (96 ± 5 mV) with a fast heterogeneous rate constant value of 2 × 10-3 cm s-1. To improve the electrode electrochemical properties, both the PES and the classical 3D-printed electrode surfaces were modified with a combination of multiwalled carbon nanotubes (MWCNTs), graphene oxide (GO), and copper. Both electrode surfaces demonstrated the suitable oxidation of nitrite at 0.6 and 0.5 V vs Ag, respectively. The calculated analytical sensitivities for PES and 3D-printed electrodes were 0.005 and 0.002 μA/(μmol L-1), respectively. The proposed PES was applied for the indirect amperometric analysis of S-nitroso-cysteine (CysNO) in serum samples via nitrite quantitation, demonstrating a limit of detection of 4.1 μmol L-1, with statistically similar values when compared to quantitative analysis of the same samples by spectrophotometry (paired t test, 95% confidence limit). The evaluated electroanalytical approach exhibited linear behavior for nitrite in the concentration range between 10 and 125 μmol L-1, which is suitable for realizing clinical diagnosis involving Parkinson's disease, for example. This proof of concept shows the great promise of this recyclable strategy combining ABS residues and conductive particles in the context of green chemical protocols for constructing disposable sensors.
Collapse
Affiliation(s)
- Habdias A Silva-Neto
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO Brazil
| | | | - Danielly S Rocha
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO Brazil
| | - Fethi Bedioui
- Institute of Chemistry for Life and Health Sciences i-CLeHS, Chimie ParisTech-PSL/CNRS, Paris 8060, France
| | - Anne Varenne
- Institute of Chemistry for Life and Health Sciences i-CLeHS, Chimie ParisTech-PSL/CNRS, Paris 8060, France
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO Brazil
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas 13084-971, São Paulo Brazil
| |
Collapse
|
9
|
Chen YH, Yang J, Wu H, Beier KT, Sawan M. Challenges and future trends in wearable closed-loop neuromodulation to efficiently treat methamphetamine addiction. Front Psychiatry 2023; 14:1085036. [PMID: 36911117 PMCID: PMC9995819 DOI: 10.3389/fpsyt.2023.1085036] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 02/03/2023] [Indexed: 02/25/2023] Open
Abstract
Achieving abstinence from drugs is a long journey and can be particularly challenging in the case of methamphetamine, which has a higher relapse rate than other drugs. Therefore, real-time monitoring of patients' physiological conditions before and when cravings arise to reduce the chance of relapse might help to improve clinical outcomes. Conventional treatments, such as behavior therapy and peer support, often cannot provide timely intervention, reducing the efficiency of these therapies. To more effectively treat methamphetamine addiction in real-time, we propose an intelligent closed-loop transcranial magnetic stimulation (TMS) neuromodulation system based on multimodal electroencephalogram-functional near-infrared spectroscopy (EEG-fNIRS) measurements. This review summarizes the essential modules required for a wearable system to treat addiction efficiently. First, the advantages of neuroimaging over conventional techniques such as analysis of sweat, saliva, or urine for addiction detection are discussed. The knowledge to implement wearable, compact, and user-friendly closed-loop systems with EEG and fNIRS are reviewed. The features of EEG and fNIRS signals in patients with methamphetamine use disorder are summarized. EEG biomarkers are categorized into frequency and time domain and topography-related parameters, whereas for fNIRS, hemoglobin concentration variation and functional connectivity of cortices are described. Following this, the applications of two commonly used neuromodulation technologies, transcranial direct current stimulation and TMS, in patients with methamphetamine use disorder are introduced. The challenges of implementing intelligent closed-loop TMS modulation based on multimodal EEG-fNIRS are summarized, followed by a discussion of potential research directions and the promising future of this approach, including potential applications to other substance use disorders.
Collapse
Affiliation(s)
- Yun-Hsuan Chen
- CenBRAIN Neurotech Center of Excellence, School of Engineering, Westlake University, Hangzhou, China
- Institute of Advanced Technology, Westlake Institute for Advanced Study, Hangzhou, China
| | - Jie Yang
- CenBRAIN Neurotech Center of Excellence, School of Engineering, Westlake University, Hangzhou, China
- Institute of Advanced Technology, Westlake Institute for Advanced Study, Hangzhou, China
| | - Hemmings Wu
- Department of Neurosurgery, Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China
| | - Kevin T. Beier
- Department of Physiology and Biophysics, University of California, Irvine, Irvine, CA, United States
- Department of Neurobiology and Behavior, University of California, Irvine, Irvine, CA, United States
- Department of Biomedical Engineering, University of California, Irvine, Irvine, CA, United States
- Department of Pharmaceutical Sciences, University of California, Irvine, Irvine, CA, United States
- Center for the Neurobiology of Learning and Memory, University of California, Irvine, Irvine, CA, United States
| | - Mohamad Sawan
- CenBRAIN Neurotech Center of Excellence, School of Engineering, Westlake University, Hangzhou, China
- Institute of Advanced Technology, Westlake Institute for Advanced Study, Hangzhou, China
| |
Collapse
|
10
|
Ultrasensitive and rapid detection of methamphetamine in forensic biological fluids using fluorescent apta-nanobiosensors based on CdTe quantum dots. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
|
11
|
Peng W, Zong XQ, Xie TT, Zhou JW, Yue MF, Wen BY, Wang YH, Chen J, Zhang YJ, Li JF. Ultrafast and field-based detection of methamphetamine in hair with Au nanocake-enhanced Raman spectroscopy. Anal Chim Acta 2022; 1235:340531. [DOI: 10.1016/j.aca.2022.340531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 10/08/2022] [Accepted: 10/14/2022] [Indexed: 11/17/2022]
|
12
|
Joosten F, Parrilla M, van Nuijs AL, Ozoemena KI, De Wael K. Electrochemical detection of illicit drugs in oral fluid: potential for forensic drug testing. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.141309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
13
|
Alizadeh M, Asrami PN, Altuner EE, Gulbagca F, Tiri RNE, Aygun A, Kaynak İ, Sen F, Cheraghi S. An ultra-sensitive rifampicin electrochemical sensor based on Fe 3O 4 nanoparticles anchored Multiwalled Carbon nanotube modified glassy carbon electrode. CHEMOSPHERE 2022; 309:136566. [PMID: 36152837 DOI: 10.1016/j.chemosphere.2022.136566] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 09/07/2022] [Accepted: 09/18/2022] [Indexed: 06/16/2023]
Abstract
This study aimed to guide future sensor studies against other pharmaceutical drugs by synthesizing Fe3O4NPs@MWCNT metallic nanoparticles (NPs). Side damage caused by excessive accumulation of tuberculosis drugs in the body can cause clots in the organs, and cause serious damage such as heart attack and respiratory failure, and threaten human life. Therefore, the development of sensors sensitive to various antibiotics in this study is important for human health. In this study, the sensitivity of Fe3O4 NPs to tuberculosis drug (rifampicin) was evaluated by catalytic reaction using bare/GCE, MWCNT/GCE, and Fe3O4NPs@MWCNT/GCE electrodes. First of all, Fe3O4 NPs were successfully synthesized for the study and MWCNT/GCE and Fe3O4 NPs@MWCNT/GCE electrodes were formed with the modification of the MWCNT support material. It was observed that the Fe3O4 NPs@MWCNT/GCE electrode gave the highest signal against the other electrodes. The morphological structure of Fe3O4 NPs was determined by various characterization techniques such as Transmission Electron Microscopy (TEM), Fourier Transmission Infrared Spectroscopy (FTIR), ultraviolet-visible (UV-Vis), and X-ray differential (XRD) and the obtained NPs were used for sensor studies, and it was observed that the current intensity increased as the scanning speed of each electrode increased in CV and DPV measurements. The average size of Fe3O4 NPs was found to be 7.32 ± 3.2 nm. Anodic current peaks occurred in the linear range of 2-25 μM. According to the results obtained from the measurements, the limit of detection (LOD) value was calculated as 0.64 μM limit of quantification (LOQ) 1.92 μM.
Collapse
Affiliation(s)
- Marzie Alizadeh
- Oral and Dental Disease Research Center, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | | | - Elif Esra Altuner
- Sen Research Group, Department of Biochemistry, University of Dumlupinar, 43000, Kutahya, Turkiye
| | - Fulya Gulbagca
- Sen Research Group, Department of Biochemistry, University of Dumlupinar, 43000, Kutahya, Turkiye
| | - Rima Nour Elhouda Tiri
- Sen Research Group, Department of Biochemistry, University of Dumlupinar, 43000, Kutahya, Turkiye
| | - Aysenur Aygun
- Sen Research Group, Department of Biochemistry, University of Dumlupinar, 43000, Kutahya, Turkiye
| | - İdris Kaynak
- Department of Machinery and Metal Technologies, University of Usak, 64000, Usak, Turkiye
| | - Fatih Sen
- Sen Research Group, Department of Biochemistry, University of Dumlupinar, 43000, Kutahya, Turkiye.
| | - Somaye Cheraghi
- Department of Chemistry, Shahid Bahonar University of Kerman, Kerman, Iran.
| |
Collapse
|
14
|
Kerry GL, Ross KE, Wright JL, Walker GS. A Review of Methods Used to Detect Methamphetamine from Indoor Air and Textiles in Confined Spaces. TOXICS 2022; 10:710. [PMID: 36422918 PMCID: PMC9695000 DOI: 10.3390/toxics10110710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 11/02/2022] [Accepted: 11/16/2022] [Indexed: 06/16/2023]
Abstract
Methamphetamine manufacture, use, and the resulting contamination is a significant issue that affects public health, the environment, and the economy. Third-hand exposure to methamphetamine can result in adverse health risks for individuals and first responders. Such exposures can result from the inhalation of airborne residues or from contact with contaminated objects. This review was conducted to determine the current methods used for methamphetamine extraction from indoor air and porous fabric materials. Dynamic solid phase microextraction (SPME) and sorbent sampling tubes have been applied to extract airborne methamphetamine residues from contaminated properties. SPME and solvent extraction have been applied to sample clothing and textiles for methamphetamine detection. This review demonstrates that there is limited literature on the detection of methamphetamine from indoor air and clothing. Supplementary and consistent methods to detect methamphetamine from air and porous surfaces should be developed and published to allow better assessment of the environmental risk to public health caused by third-hand exposure to methamphetamine.
Collapse
Affiliation(s)
- Gemma L. Kerry
- Physical and Molecular Sciences, College of Science and Engineering, Flinders University, Adelaide 5042, Australia
| | - Kirstin E. Ross
- Environmental Health, College of Science and Engineering, Flinders University, Adelaide 5042, Australia
| | - Jackie L. Wright
- Environmental Health, College of Science and Engineering, Flinders University, Adelaide 5042, Australia
- Environmental Risk Sciences Pty Ltd., Carlingford Court, P.O. Box 2537, Sydney 2118, Australia
| | - G. Stewart Walker
- Physical and Molecular Sciences, College of Science and Engineering, Flinders University, Adelaide 5042, Australia
| |
Collapse
|
15
|
Ghorbanizamani F, Moulahoum H, Guler Celik E, Timur S. Ionic liquid-hydrogel hybrid material for enhanced electron transfer and sensitivity towards electrochemical detection of methamphetamine. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.119627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
16
|
Boroujerdi R, Paul R. Graphene-Based Electrochemical Sensors for Psychoactive Drugs. NANOMATERIALS 2022; 12:nano12132250. [PMID: 35808086 PMCID: PMC9267978 DOI: 10.3390/nano12132250] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 06/24/2022] [Accepted: 06/26/2022] [Indexed: 12/11/2022]
Abstract
Sensors developed from nanomaterials are increasingly used in a variety of fields, from simple wearable or medical sensors to be used at home to monitor health, to more complicated sensors being used by border customs or aviation industries. In recent times, nanoparticle-based sensors have begun to revolutionize drug-detection techniques, mainly due to their affordability, ease of use and portability, compared to conventional chromatography techniques. Thin graphene layers provide a significantly high surface to weight ratio compared to other nanomaterials, a characteristic that has led to the design of more sensitive and reliable sensors. The exceptional properties of graphene coupled with its potential to be tuned to target specific molecules have made graphene-based sensors one of the most popular and well-researched sensing materials of the past two decades with applications in environmental monitoring, medical diagnostics, and industries. Here, we present a review of developments in the applications of graphene-based sensors in sensing drugs such as cocaine, morphine, methamphetamine, ketamine, tramadol and so forth in the past decade. We compare graphene sensors with other sensors developed from ultrathin two-dimensional materials, such as transition-metal dichalcogenides, hexagonal boron nitrate, and MXenes, to measure drugs directly and indirectly, in various samples.
Collapse
|
17
|
Freitas A, Vieira I. Sensor modified with gold nanoparticles stabilized in dialdehyde starch/DMSO matrix for methyldopa detection. ELECTROANAL 2022. [DOI: 10.1002/elan.202100529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
18
|
Vannoy KJ, Tarolla NE, Kauffmann PJ, Clark RB, Dick JE. Detecting Methamphetamine in Aerosols by Electroanalysis in a Soap Bubble Wall. Anal Chem 2022; 94:6311-6317. [PMID: 35416032 DOI: 10.1021/acs.analchem.2c00462] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We present a facile method to detect methamphetamine in aerosols by trapping aerosols in a soap bubble wall for electroanalysis. A microwire was placed through a soap bubble wall as a sensing electrode along with a 1 mm diameter platinum wire as the counter/reference electrode. The resulting electrochemical cell and electrode geometry are unique and allow for reproducible electrochemistry between bubble walls. We first provide a thorough investigation of the cell and electrode geometry and an electrochemical characterization of ferrocene methanol in a soap bubble wall composed of 0.1 M KCl and 0.1% Triton X-100 (v/v). To visualize the boundary where the bubble wets the microwire (the effective electrode area) with tens of nanometer resolution, we electrodeposited platinum on carbon microwire. Scanning electron microscopy and energy dispersive X-ray spectroscopy revealed the bubble contact (i.e., cylindrical electrode height) is 157 ± 30 μm. Correlated digital microscopy suggests that the wetting reaches r ∼ 125 μm along the bubble wall laterally from the microwire. Beyond the wetting region, the bubble thickness is 18 ± 1 μm, as indicated by ultraviolet-visible spectroscopy experiments probing dissolved bis(bipyridine)ruthenium(II) chloride. We illustrate that the voltammetric character in this system is highly dependent on the bubble wetting parameters, which are tuned by changing the microwire material. We then applied this system to the collection and electrochemical detection of methamphetamine in liquid aerosols, where the bubble wall acts as a low volume collector.
Collapse
Affiliation(s)
- Kathryn J Vannoy
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Nicole E Tarolla
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Philip J Kauffmann
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Rebecca B Clark
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| | - Jeffrey E Dick
- Department of Chemistry, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States.,Lineberger Comprehensive Cancer Center, School of Medicine, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, United States
| |
Collapse
|
19
|
Elancheziyan M, Theyagarajan K, Ponnusamy VK, Thenmozhi K, Senthilkumar S. Porous graphene oxide based disposable non-enzymatic electrochemical sensor for the determination of nicotinamide adenine dinucleotide. MICRO AND NANO ENGINEERING 2022. [DOI: 10.1016/j.mne.2022.100133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
20
|
Yang Z, Zhong Y, Zhou X, Zhang W, Yin Y, Fang W, Xue H. Metal-organic framework-based sensors for nitrite detection: a short review. JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION 2022. [DOI: 10.1007/s11694-021-01270-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
21
|
Sohrabi H, Majidi MR, Asadpour-Zeynali K, Khataee A, Mokhtarzadeh A. Bimetallic Fe/Mn MOFs/MβCD/AuNPs stabilized on MWCNTs for developing a label-free DNA-based genosensing bio-assay applied in the determination of Salmonella typhimurium in milk samples. CHEMOSPHERE 2022; 287:132373. [PMID: 34600005 DOI: 10.1016/j.chemosphere.2021.132373] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Revised: 09/12/2021] [Accepted: 09/24/2021] [Indexed: 06/13/2023]
Abstract
Monitoring of pathogenic bacteria plays a vital role in precluding foodborne disease outbreaks. In this research work, a genosensor based on innovative label-free DNA was developed for the detection of Salmonella. typhimurium (S. typhimurium) in the milk samples. To realize this objective, bimetallic Fe/Mn MOF is synthesized and mixed with methyl-β-cyclodextrin (MβCD) and AuNPs which are then stabilized on multi-walled carbon nanotubes (MWCNTs), and the obtained nanocomposite is immobilized on the Au electrode surface. Different characterization methods such as FE-SEM, TEM, EDS, FTIR, and XRD were used for investigating the particle size and morphological features. Electrochemical and impedimetric techniques were used for exploring the applicability of the fabricated genosensor. Under optimal circumstances, LOD and LOQ have acquired at 0.07 pM and 0.21 pM. Moreover, an extensive linear range of 1 pM-1 μM was resulted for ss-tDNA (single-stranded target DNA), R2 obtained 0.9991. The recoveries were obtained 95.6-104%. Great selectivity against one, two, and three-base mismatched sequences was also shown for fabricated biosensing assay. Furthermore, negative genosensing assay control for investigating selectivity was provided by the ss-tDNAs of Haemophilusinfluenzae and Shigella dysenteriae bacteria. Well-fabricated genosensing bio-assay represents better performance, great specificity, high sensitivity, increased active sites, and finally results in an increase in the electron transfer rate. It is to be noted that the organized genosensing bio-assay is capable of being re-used and re-generated in a straightforward manner to estimate the hybridization process.
Collapse
Affiliation(s)
- Hessamaddin Sohrabi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, 51666 16471, Tabriz, Iran
| | - Mir Reza Majidi
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, 51666 16471, Tabriz, Iran.
| | - Karim Asadpour-Zeynali
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, 51666 16471, Tabriz, Iran; Pharmaceutical Analysis Research Center, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, 51664, Iran
| | - Alireza Khataee
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471, Tabriz, Iran; Department of Environmental Engineering, Gebze Technical University, 41400, Gebze, Turkey; Department of Material Science and Physical Chemistry of Materials, South Ural State University, 454080, Chelyabinsk, Russian Federation
| | - Ahad Mokhtarzadeh
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| |
Collapse
|
22
|
Chang JH, Shen SY, Dong CD, Shkir M, Kumar M. Morphology-dependent MoO 3/Ni-F nanostructures with enhanced electrochemical hydrogen peroxide detection. CHEMOSPHERE 2022; 287:131960. [PMID: 34438213 DOI: 10.1016/j.chemosphere.2021.131960] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 08/03/2021] [Accepted: 08/18/2021] [Indexed: 06/13/2023]
Abstract
The present report investigates the various MoO3 morphologies prepared via different approaches such as morphologies are cubic sheet, ribbon, and hexagonal sheet. These prepared nanostructures are modified as a MoO3/Ni-F electrode used to detect hydrogen peroxide (H2O2). The influence of the morphology on the microstructural, morphological, electronic state, optical and electrochemical properties of MoO3 nanostructures are systematically studied. The recorded XRD spectra confirmed that the good crystalline nature with the orthorhombic crystal structure. The FESEM analysis shows that preparation approaches strongly influenced the MoO3 morphology. The elemental mapping and XPS analysis confirm the formation of MoO3. The obtained optical band gap values show that the MoO3 morphology-based bandgap values are 3.38, 3.17, and 2.94 eV. The modified MoO3/Ni-F electrode electrochemical impedance spectra show the CP-MoO3 has good conductivity. Moreover, the CP-MoO3/Ni-F electrode has a wide detection window, long-term stability, reproducibility, and a low detection limit is 1.2 μM. Hence, the CP-MoO3/Ni-F electrode electrochemical results suggest that the modified electrode has offered a good matrix for toxic contaminants sensing applications.
Collapse
Affiliation(s)
- Jih-Hsing Chang
- Department of Environmental Engineering and Management, Chaoyang University of Technology, Taichung City, 413310, Taiwan
| | - Shan-Yi Shen
- Department of Environmental Engineering and Management, Chaoyang University of Technology, Taichung City, 413310, Taiwan
| | - Cheng-Di Dong
- Department of Marine Environmental Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, 81157, Taiwan
| | - Mohd Shkir
- Advanced Functional Materials & Optoelectronics Laboratory (AFMOL), Department of Physics, Faculty of Science, King Khalid University, P.O Box-9004, Abha, 61413, Saudi Arabia
| | - Mohanraj Kumar
- Department of Environmental Engineering and Management, Chaoyang University of Technology, Taichung City, 413310, Taiwan.
| |
Collapse
|
23
|
Zhang H, Xia C, Feng G, Fang J. Hospitals and Laboratories on Paper-Based Sensors: A Mini Review. SENSORS 2021; 21:s21185998. [PMID: 34577205 PMCID: PMC8472957 DOI: 10.3390/s21185998] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 09/01/2021] [Accepted: 09/02/2021] [Indexed: 02/07/2023]
Abstract
With characters of low cost, portability, easy disposal, and high accuracy, as well as bulky reduced laboratory equipment, paper-based sensors are getting increasing attention for reliable indoor/outdoor onsite detection with nonexpert operation. They have become powerful analysis tools in trace detection with ultra-low detection limits and extremely high accuracy, resulting in their great popularity in medical detection, environmental inspection, and other applications. Herein, we summarize and generalize the recently reported paper-based sensors based on their application for mechanics, biomolecules, food safety, and environmental inspection. Based on the biological, physical, and chemical analytes-sensitive electrical or optical signals, extensive detections of a large number of factors such as humidity, pressure, nucleic acid, protein, sugar, biomarkers, metal ions, and organic/inorganic chemical substances have been reported via paper-based sensors. Challenges faced by the current paper-based sensors from the fundamental problems and practical applications are subsequently analyzed; thus, the future directions of paper-based sensors are specified for their rapid handheld testing.
Collapse
|