1
|
Abdulra'uf LB, Junaid AM, Lawal AR, Ibrahim HB, Tan GH. Determination of pesticide residues in beans using QuEChERS technique coupled to gas chromatography-mass spectrometry: Multivariate optimization of CEN and AOAC methods. Food Chem 2025; 463:141464. [PMID: 39369599 DOI: 10.1016/j.foodchem.2024.141464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2024] [Revised: 09/24/2024] [Accepted: 09/26/2024] [Indexed: 10/08/2024]
Abstract
The use of pesticides has led to environmental pollution and posed a global health risk, since they remain as residues on foods. Beans one of the most widely cultivated crop in Africa, and susceptible to attack by insects both on field and during storage, leading to the application of pesticides to control pests' infestation. However, misuse of these chemicals by farmers on beans has resulted in the rejection of beans exported to European countries, due to the presence of pesticide residues at concentrations higher than the maximum residues levels (MRLs). In this study, the effectiveness of the Association Official Analytical Chemists (AOAC) Official Method and the European Committee of Standardization (CEN) Standard Method, were determined using multivariate approach for the analysis of organochlorine pesticide residues in 6 varieties of beans samples. The significance of factors (mass of sample, volume of acetonitrile, mass of magnesium sulphate, sample pH, centrifugation time and speed) affecting the efficiency of extraction was estimated using Plackett-Burman design, while central composite design was used to optimize the significant factors. The following optimum factors were subsequently used for method validation, recovery tests, and real sample analysis: 4 g of sample sludge (1:1 v/v), 10 mL of acetonitrile, 4.45 g of MgSO4, and 5 min of centrifugation at 5000 rpm. The figure of merit of analytical methodology estimated using matrix-matched internal standard calibration method gave linearity ranging from 0.25 to 500 μg/kg, with correlation coefficient (R2) greater than 0.99, the recovery ranged from 75.55 to 110.41 (RSD = 0.70-16.65), with LOD and LOQ of 0.23-1.77 μg/kg and 0.76-5.88 μg/kg, respectively.
Collapse
Affiliation(s)
- Lukman Bola Abdulra'uf
- Department of Chemistry and Industrial Chemistry, Faculty of Pure and Applied Sciences, Kwara State University Malete, P. M. B. 1530, Ilorin, Nigeria; Department of Chemistry, Faculty of Science, University of Malaya, Kuala Lumpur, Malaysia.
| | - Abibat Monisola Junaid
- Department of Chemistry and Industrial Chemistry, Faculty of Pure and Applied Sciences, Kwara State University Malete, P. M. B. 1530, Ilorin, Nigeria; Department of Chemistry, School of Science, Kwara State College of Education, P. M. B. 1525, Ilorin, Nigeria.
| | - Amudalat Ranti Lawal
- Department of Plant and Environmental Biology, Faculty of Pure and Applied Sciences, Kwara State University Malete, P. M. B. 1530, Ilorin, Nigeria.
| | - Hassan Bisiriyu Ibrahim
- Department of Integrated Science, School of Sciences, Kwara State College of Education, P. M. B. 1525, Ilorin, Nigeria.
| | - Guan Huat Tan
- Department of Chemistry, Faculty of Science, University of Malaya, Kuala Lumpur, Malaysia.
| |
Collapse
|
2
|
de Albuquerque Mendes MK, dos Santos Oliveira CB, da Silva Medeiros CM, Dantas C, Carrilho E, de Araujo Nogueira AR, Lopes Júnior CA, Vieira EC. Application of experimental design as a statistical approach to recover bioactive peptides from different food sources. Food Sci Biotechnol 2024; 33:1559-1583. [PMID: 38623435 PMCID: PMC11016049 DOI: 10.1007/s10068-024-01540-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 01/12/2024] [Accepted: 02/06/2024] [Indexed: 04/17/2024] Open
Abstract
Bioactive peptides (BAPs) derived from samples of animals and plants have been widely recommended and consumed for their beneficial properties to human health and to control several diseases. This work presents the applications of experimental designs (DoE) used to perform factor screening and/or optimization focused on finding the ideal hydrolysis condition to obtain BAPs with specific biological activities. The collection and discussion of articles revealed that Box Behnken Desing and Central Composite Design were the most used. The main parameters evaluated were pH, time, temperature and enzyme/substrate ratio. Among vegetable protein sources, soy was the most used in the generation of BAPs, and among animal proteins, milk and shrimp stood out as the most explored sources. The degree of hydrolysis and antioxidant activity were the most investigated responses in obtaining BAPs. This review brings new information that helps researchers apply these DoE to obtain high-quality BAPs with the desired biological activities.
Collapse
Affiliation(s)
| | | | | | - Clecio Dantas
- Departamento de Química, Universidade Estadual do Maranhão – UEMA, P.O. Box, 65604-380, Caxias, MA Brazil
| | - Emanuel Carrilho
- Instituto de Química de São Carlos, Universidade de São Paulo, São Carlos, SP 13566-590 Brazil
| | | | - Cícero Alves Lopes Júnior
- Departamento de Química, Universidade Federal do Piauí – UFPI, P.O. Box 64049-550, Teresina, PI Brazil
| | - Edivan Carvalho Vieira
- Departamento de Química, Universidade Federal do Piauí – UFPI, P.O. Box 64049-550, Teresina, PI Brazil
| |
Collapse
|
3
|
Drimaropoulou G, Christophoridis C, Zacharis CK, Fytianos K. Chemometric Optimization of SPE for the Determination of Multiclass Pesticides in Portable Water Samples by UHPLC-MS/MS. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY 2024; 112:48. [PMID: 38459992 PMCID: PMC10924705 DOI: 10.1007/s00128-024-03873-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 02/26/2024] [Indexed: 03/11/2024]
Abstract
This study aimed on the development of a SPE-UHPLC-MS/MS method for the simultaneous determination of pesticide residues in drinking water samples. A chemometric approach was applied to optimize the efficiency of the SPE pretreatment procedure. This study involved (i) the application of a Full Factorial Design for the screening of the significant factors, (ii) the application of a Central Composite Design for the determination of the optimal conditions and (iii) the evaluation and validation of the significance of the statistically proposed models. Oasis HLB cartridges were used for the extraction. The optimum sample volume was 300 mL and the elution solvent 3 mL of the mixture of methanol:ethylacetate 70:30 v/v. The method was validated according to the international guidelines. Recoveries were ranged from 63 to 116% and the detection limits were between 0.1 and 1.5 pg mL- 1. The validated method could be used in routine analysis for pesticides screening.
Collapse
Affiliation(s)
- Garyfallia Drimaropoulou
- Environmental Pollution Control Laboratory, Chemistry Department, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece
| | - Christophoros Christophoridis
- Environmental Pollution Control Laboratory, Chemistry Department, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece
| | - Constantinos K Zacharis
- Laboratory of Pharmaceutical Analysis, Department of Pharmacy, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece
| | - Konstantinos Fytianos
- Environmental Pollution Control Laboratory, Chemistry Department, Aristotle University of Thessaloniki, Thessaloniki, 54124, Greece.
| |
Collapse
|
4
|
Nunavath RS, Singh MT, Jain A, Chakma M, Arivuselvam R, Azeeze MSTA. Quality by Design in Pharmaceuticals: A Review of its Impact on Regulatory Compliance and Product Quality. Drug Res (Stuttg) 2024; 74:18-23. [PMID: 38134919 DOI: 10.1055/a-2185-4916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2023]
Abstract
The pharmaceutical industry has embraced the quality-by-design (QbD) approach as a promising development, formulation and manufacturing strategy. QbD provides a systematic and science-based framework for designing and producing high-quality products, with a particular focus on identifying, assessing and controlling risks throughout the development process. This review aims to assess the benefits of implementing QbD in pharmaceutical processes, evaluate its impact on regulatory compliance and explore its potential to enhance drug product quality. The primary objective of this review is to evaluate the influence of QbD on pharmaceutical development and manufacturing processes. It also seeks to examine the regulatory requirements associated with the implementation of QbD and highlight the advantages of this approach in terms of product quality and cost-effectiveness. Additionally, the review aims to explore the potential of QbD in improving the safety and efficacy of drug products. The QbD approach holds tremendous potential to revolutionize the pharmaceutical industry by optimizing drug development & manufacturing processes, reducing costs and enhancing product quality and consistency. However, implementing QbD requires a comprehensive understanding of the underlying science, as well as strict adherence to regulatory requirements in drug development and manufacturing. In conclusion, by embracing the QbD approach, the pharmaceutical industry can ensure the production of safe, effective and regulation-compliant products while simultaneously improving process efficiency. This strategic shift toward QbD represents a pivotal step in advancing pharmaceutical research and manufacturing capabilities, ultimately benefiting both the industry and more importantly, patients worldwide.
Collapse
Affiliation(s)
- Raja Shekhar Nunavath
- Department of Pharmaceutical Analysis, JSS College of Pharmacy, JSS Academy of Higher Education & Research, Ooty, The Nilgiris, Tamil Nadu, India
| | - Madhu Tanya Singh
- Department of Pharmacology, JSS College of Pharmacy, JSS Academy of Higher Education & Research, Ooty, The Nilgiris, Tamil Nadu, India
| | - Anubha Jain
- Department of Pharmaceutical Chemistry, Shri Aurobindo College of Pharmacy, Indore, Madhya Pradesh, India
| | - Marjita Chakma
- Department of Pharmaceutics, College of Pharmacy, JSS Academy of Technical Education, Noida, Uttar Pradesh, India
| | - Rajaguru Arivuselvam
- Department of Pharmaceutical Biotechnology, JSS College of Pharmacy, JSS Academy of Higher Education & Research, Sri Shivarathreeshwara Nagar, Mysore, KA, India
| | - Mohamed Sheik Tharik Abdul Azeeze
- Department of Pharmaceutical Analysis, College of Pharmacy, JSS Academy of Technical Education, Noida, Uttar Pradesh, India
- Department of Pharmaceutical Analysis, Faculty of Pharmacy, Karpagam Academy of Higher Education, Coimbatore, Tamil Nadu, India
| |
Collapse
|
5
|
Alves Rocha B, Gallimberti M, Paulo Bianchi Ximenez J, Giovana Basso C, Joel Martino-Andrade A, Martin Koch H, Augusto Calixto L, Barbosa F. An eco-friendly sample preparation procedure based on air-assisted liquid-liquid microextraction for the rapid determination of phthalate metabolites in urine samples by liquid chromatography-tandem mass spectrometry. Talanta 2024; 266:124974. [PMID: 37494769 DOI: 10.1016/j.talanta.2023.124974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 07/07/2023] [Accepted: 07/18/2023] [Indexed: 07/28/2023]
Abstract
Urinary phthalate metabolite (mPAEs) analysis is a reliable tool for assessing human exposure to phthalates. With growing interest in urinary biomonitoring of these metabolites, there is a need for fast and sensitive analytical methods. Therefore, a simple, rapid procedure for simultaneous determination of fifteen phthalate metabolites in human urine samples by liquid chromatography-tandem mass spectrometry was developed. The novelty of the present procedure is based on the use of diethyl carbonate as a green biobased extraction solvent and air-assisted liquid-liquid microextraction (AALLME) as a sample preparation step. A Plackett-Burman design was used for screening the factors that influence the AALLME extraction efficiency of mPAEs. The effective factors were then optimized by response surface methodology using a central composite rotatable design. Under the optimized conditions, good linearity can be achieved in a concentration range of 1.0-20.0 ng mL-1 with correlation coefficients higher than 0.99. The repeatability and reproducibility precision were in the range of 2-12% and 1-10% respectively. Recoveries ranging from 90% to 110%. This, and the low limits of detection, ranging from 0.01 to 0.05 ng mL-1, make the proposed procedure sensitive and suitable for human biomonitoring of phthalate exposures. For proof-of-principle, the new method was used to measure the urinary concentrations of mPAEs in 20 urine samples from Brazilian women. The high frequency of detections and in part high concentrations of mPAEs indicate to widespread exposure to several phthalates among Brazilian women.
Collapse
Affiliation(s)
- Bruno Alves Rocha
- Analytical and System Toxicology Laboratory, Department of Clinical Analyses, Toxicology and Food Sciences, School of Pharmaceutical Sciences of Ribeirao Preto, University of Sao Paulo, Avenida do Cafe s/nº, Ribeirao Preto, Sao Paulo, 14040-903, Brazil.
| | - Matheus Gallimberti
- Analytical and System Toxicology Laboratory, Department of Clinical Analyses, Toxicology and Food Sciences, School of Pharmaceutical Sciences of Ribeirao Preto, University of Sao Paulo, Avenida do Cafe s/nº, Ribeirao Preto, Sao Paulo, 14040-903, Brazil
| | - João Paulo Bianchi Ximenez
- Analytical and System Toxicology Laboratory, Department of Clinical Analyses, Toxicology and Food Sciences, School of Pharmaceutical Sciences of Ribeirao Preto, University of Sao Paulo, Avenida do Cafe s/nº, Ribeirao Preto, Sao Paulo, 14040-903, Brazil
| | - Carla Giovana Basso
- Department of Physiology, Animal Endocrine and Reproductive Physiology Laboratory, Federal University of Paraná (UFPR), Curitiba, Parana, Brazil
| | - Anderson Joel Martino-Andrade
- Department of Physiology, Animal Endocrine and Reproductive Physiology Laboratory, Federal University of Paraná (UFPR), Curitiba, Parana, Brazil
| | - Holger Martin Koch
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bürkle-de-la-Camp-Platz 1, 44789, Bochum, Germany
| | - Leandro Augusto Calixto
- Department of Pharmaceutical Sciences, Institute of Environmental, Chemistry and Pharmaceutical Science, Federal University of São Paulo, São Paulo, 099972-270, Brazil
| | - Fernando Barbosa
- Analytical and System Toxicology Laboratory, Department of Clinical Analyses, Toxicology and Food Sciences, School of Pharmaceutical Sciences of Ribeirao Preto, University of Sao Paulo, Avenida do Cafe s/nº, Ribeirao Preto, Sao Paulo, 14040-903, Brazil
| |
Collapse
|
6
|
Ultrasonic-Assisted Extraction of Flavonoids from Juglans mandshurica Maxim.: Artificial Intelligence-Based Optimization, Kinetics Estimation, and Antioxidant Potential. Molecules 2022; 27:molecules27154837. [PMID: 35956798 PMCID: PMC9369614 DOI: 10.3390/molecules27154837] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 07/16/2022] [Accepted: 07/25/2022] [Indexed: 12/02/2022] Open
Abstract
Ultrasonic-assisted extraction (UAE) of flavonoids (JMBF) from Juglans mandshurica Maxim., an important industrial crop in China, was investigated in the present study. To improve the extraction efficiency of JMBF, suitable UAE was proposed after optimization using a hybrid response surface methodology–artificial neural network–genetic algorithm approach (RSM–ANN–GA). The maximum extraction yield (6.28 mg·g−1) of JMBF was achieved using the following optimum UAE conditions: ethanol concentration, 62%; solid–liquid ratio, 1:20 g·mL−1; ultrasonic power, 228 W; extraction temperature, 60 °C; extraction time, 40 min; total number of extractions, 1. Through the investigation of extraction kinetics, UAE offered a higher saturated concentration (Cs) for JMBF in comparison to traditional solvent extraction (TSE). Scanning electron microscopy (SEM) images showed that deeper holes were generated in J. mandshurica powder under the action of ultrasound, indicating that ultrasound significantly changed the structure of the plant materials to facilitate the dissolution of active substances. Extracts obtained using UAE and TSE were compared by Fourier-transform infrared spectroscopy analysis, the results of which revealed that the functional group of bioactive compounds in the extract was unaffected by the ultrasonication process. Moreover, JMBF was further shown to exhibit significant antioxidant properties in vitro. This study provides a basis for the application of JMBF as a natural antioxidant.
Collapse
|
7
|
Nemati M, Altunay N, Tuzen M, Farajzadeh MA, Mogaddam MRA. In-situ sorbent formation for the extraction of pesticides from honey. J Sep Sci 2022; 45:2652-2662. [PMID: 35596522 DOI: 10.1002/jssc.202100963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 04/30/2022] [Accepted: 05/03/2022] [Indexed: 11/06/2022]
Abstract
An organic polymer was re-precipitated in solution to use as an adsorbent in dispersive solid phase extraction of some pesticides from honey samples prior to their determination by high performance liquid chromatography-tandem mass spectrometry. In this approach, different deep eutectic solvents were prepared using lysine and their ability in elution of the analytes from the adsorbent surface were tested. A diluted honey solution was transferred into a glass test tube and then a solution of polystyrene dissolved in dimethylformamide was injected into the solution. By doing this, polystyrene re-precipitated in the solution and dispersed in whole parts of it as many tiny particles. Then the mixture was centrifuged and the adsorbed analytes on the particles were eluted using a proper hydrophilic deep eutectic solvent. Central composite design approach was used for optimization of effective parameters. The limits of detection and quantification were in the ranges of 0.06-0.20 and 0.22-0.69 ng/g, respectively. The calibration curves obtained by matrix-matched standard solutions were linear in the range of 0.69-500 ng/g with coefficient of determinations ≥0.9962. The method provided high extraction recoveries (70-99%) and enrichment factors (140-198), and an acceptable precision (relative standard deviations ≤7.1%). This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Mahboob Nemati
- Food and Drug Safety Research, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Nail Altunay
- Department of Chemistry, Sivas Cumhuriyet University, Sivas, TR-58140, Turkey
| | - Mustafa Tuzen
- Art and Science Faculty, Chemistry Department, Tokat Gaziosmanpasa University, Tokat, 60250, Turkey.,Center for Environment and Marine Studies, King Fahd University of Petroleum and Minerals, Research Institute, Dhahran, 31261, Saudi Arabia
| | - Mir Ali Farajzadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.,Engineering Faculty, Near East University, North Cyprus, Mersin 10, Nicosia, 99138, Turkey
| | - Mohammad Reza Afshar Mogaddam
- Food and Drug Safety Research, Tabriz University of Medical Sciences, Tabriz, Iran.,Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
8
|
Kamal AH, Hammad MA, Kannouma RE, Mansour FR. Response surface optimization of a vortex-assisted dispersive liquid-liquid microextraction method for highly sensitive determination of repaglinide in environmental water by HPLC/UV. BMC Chem 2022; 16:33. [PMID: 35568922 PMCID: PMC9107645 DOI: 10.1186/s13065-022-00826-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 04/28/2022] [Indexed: 01/01/2023] Open
Abstract
A vortex-assisted dispersive liquid–liquid microextraction (DLLME) method, mated to chemometrics and combined with HPLC/UV detection was optimized and validated for enrichment and determination of repaglinide in environmental samples using nateglinide as an internal standard (IS). A phosphate buffer (10 mM, pH 2.5): acetonitrile (45:55, v/v) was used as a mobile phase with a flow rate of 1 mL/min in an isocratic elution mode. Chemometrics-assisted optimization was performed using a quadratic integrated d-optimal design. The developed model assessed the statistical significance of the independent variables and their interactions to attain the optimum conditions revealing that extractant type, extractant volume and pH are the most influential factors. Optimization of the extraction procedures was performed with the aid of Design Expert 8® software, which suggested 58 different experiments. The optimal conditions were 30 µL of 1-octanol as extractant, 100 µL of acetonitrile as a disperser at pH 8. Under the optimized conditions, the method showed linearity over the range of 1–100 ng/mL with a limit of detection of 0.4 ng/mL. The accuracy, the intra- and inter-day precision were assessed, the %recoveries were found to be between 98.48 and 100.81% with %RSD lower than 1.3. Using chemometrics in method optimization helped achieve the maximum possible enrichment with the least effort, time, and reagents while considering all possible interactions between variables.
Collapse
Affiliation(s)
- Amira H Kamal
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, 31111, Egypt
| | - Mohamed A Hammad
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Tanta, 32958, Egypt
| | - Reham E Kannouma
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Tanta, 32958, Egypt
| | - Fotouh R Mansour
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, 31111, Egypt. .,Pharmaceutical Services Center, Faculty of Pharmacy, Tanta University, Elgeish Street, Tanta, 31111, Egypt.
| |
Collapse
|
9
|
Rafiei Jam M, Nezhadali A, Kaykhaii M. Application of gas flow headspace liquid phase micro extraction coupled with gas chromatography-mass spectrometry for determination of 4-methylimidazole in food samples employing experimental design optimization. BMC Chem 2022; 16:29. [PMID: 35524272 PMCID: PMC9077832 DOI: 10.1186/s13065-022-00823-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Accepted: 04/28/2022] [Indexed: 12/05/2022] Open
Abstract
Background 4-Methylimidazole (4-MeI) or 4-methyl-1H-imidazole, a slightly yellowish solid with molecular formula C4H6N2, is a heterocyclic compound which supposedly does not exist as a natural product and is formed when carbohydrates are heating with ammonium compounds. This compound is used in pharmaceuticals, agriculture and photography chemicals, dyes and pigments, and rubber manufacturing. In the present study, a simple and efficient sample preparation method designated gas flow headspace liquid phase microextraction (GF-HS-SDME) was employed for the extraction and preconcentration of 4-methylimidazole (4-MeI) from food and beverage samples, before its determination by gas chromatography-mass spectrometry. Result To investigate the optimal conditions for the extraction process in GF-HS-SDME method, factors affecting extraction, including selection of extraction solvent, vial volume, extraction solvent ratio, position of extracting solvent, drop volume, sample volume, stirring speed, temperature, extraction time, sample pH, ionic strength of the sample solution and gas flow rate were optimized by utilizing both one-variable-at-a-time method and Plackett–Burman design. The investigation of protocol was carried out by using a standard solution containing 100.0 μg L−1 of 4-MeI in deionized water. Conclusion In this study, a simple and green analytical method based on GF-HS-SDME was proposed for the extraction and preconcentration of 4-MeI from foodstuffs, followed by GC–MS determination. The main advantage of this method is its high preconcentration factor and fastness due to the application of an inert gas stream during microextraction. Supplementary Information The online version contains supplementary material available at 10.1186/s13065-022-00823-z.
Collapse
Affiliation(s)
- Mahdiye Rafiei Jam
- Department of Chemistry, Payame Noor University, P.O. Box 19395-4697, 19569, Tehran, Iran
| | - Azizollah Nezhadali
- Department of Chemistry, Payame Noor University, P.O. Box 19395-4697, 19569, Tehran, Iran
| | - Massoud Kaykhaii
- Department of Process Engineering and Chemical Technology, Faculty of Chemistry, Gdańsk University of Technology, 80-233, Gdańsk, Poland.
| |
Collapse
|
10
|
Elik A, Demirbaş A, Altunay N. Experimental design of ligandless sonication-assisted liquid- phases microextraction based on hydrophobic deep eutectic solvents for accurate determination of Pb(II) and Cd(II) from waters and food samples at trace levels. Food Chem 2022; 371:131138. [PMID: 34555705 DOI: 10.1016/j.foodchem.2021.131138] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 08/12/2021] [Accepted: 09/12/2021] [Indexed: 12/14/2022]
Abstract
A straightforward, accurate and efficient analytical procedure was developed by ligandless sonication-assisted liquid- phases microextraction based on hydrophobic deep eutectic solvents (SA-LPME-HDES) to trace toxic Pb(II) and Cd(II) in waters and foods. Optimization of the SA-LPME-HDES procedure was carried out by Box-Behnken design. Under optimum conditions, linear ranges for Pb(II) and Cd(II) were 0.8-350 (r2:0.9962) and 1.5-500 µg L-1 (r2: 0.9937), respectively. Relative standard deviations (N = 5, 10 µg L-1) were 1.4% for Pb(II) and 1.6% for Cd(II), respectively. Limits of detection were 0.24, and 0.46 µg L-1, respectively. The accuracy was evaluated by the analysis of two certified reference materials and the results were to be in agreement with the certified values. The SA-LPME-HDES method was successfully applied to tap water, mineral water, river water, well-water, sesame, peanut, eggplant, corn, wheat, soy and cucumber. The SA-LPME-HDES method allows operational simplicity, green, and low cost when compared with some microextraction procedure.
Collapse
Affiliation(s)
- Adil Elik
- Sivas Cumhuriyet University, Chemistry Department, Sivas, Turkey
| | - Ahmet Demirbaş
- Sivas Cumhuriyet University, Department of Plant and Animal Production, Sivas, Turkey
| | - Nail Altunay
- Sivas Cumhuriyet University, Chemistry Department, Sivas, Turkey.
| |
Collapse
|
11
|
Optimization and application of ultrasound-assisted sugar based deep eutectic solvent dispersive liquid–liquid microextraction for the determination and extraction of aflatoxin M1 in milk samples. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106974] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
12
|
López-Lorente ÁI, Pena-Pereira F, Pedersen-Bjergaard S, Zuin VG, Ozkan SA, Psillakis E. The Ten Principles of Green Sample Preparation. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116530] [Citation(s) in RCA: 49] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
13
|
Abdallah IA, Hammad SF, Bedair A, Mansour FR. Sugaring-out induced homogeneous liquid-liquid microextraction as an alternative mode for biological sample preparation: A comparative study. J Sep Sci 2021; 44:3117-3125. [PMID: 34101992 DOI: 10.1002/jssc.202100255] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 06/03/2021] [Accepted: 06/04/2021] [Indexed: 02/06/2023]
Abstract
Miniaturization of liquid-liquid extraction is a growing field of sample preparation to reduce solvent consumption, protect the environment, and preserve operators' health. In this work, four different modes of liquid-liquid microextraction have been compared including dispersive liquid-liquid microextraction, binary and ternary salting-out, and sugaring-out induced liquid-liquid microextraction. The extraction efficiency was evaluated by the enrichment factors of 14 different drugs from three pharmacological classes. Compared with the other modes, sugaring-out induced liquid-liquid microextraction was found to be the most efficient and, thus, it was applied for sample preparation of the antivirals in human plasma. Method optimization was performed using response surface methodology for the sugar type and amount (in mg), the sample pH, the equilibration time (in min), and the extractant volume (in µL). The method was then validated and found linear in the concentration range of 0.10-10 µg/mL for daclatasvir, 0.05-10 µg/mL for velpatasvir, and 0.20-10 µg/mL for ledipasvir, with correlation coefficients in the range 0.996-0.999. These results shows that sugaring-out induced liquid-liquid microextraction could be a more efficient microextraction mode for preparation of biological samples. Compared with other types of microextraction, sugaring-out induced liquid-liquid microextraction is greener, simpler, and cost-effective, with less tendency to affect the sample pH.
Collapse
Affiliation(s)
- Inas A Abdallah
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, Egypt
| | - Sherin F Hammad
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt
| | - Alaa Bedair
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, Egypt
| | - Fotouh R Mansour
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, Egypt
- Pharmaceutical Services Center, Faculty of Pharmacy, Tanta University, Tanta, Egypt
| |
Collapse
|
14
|
Abbaszadeh S, Yousefinejad S, Jafari S, Soleimani E. In-syringe ionic liquid-dispersive liquid-liquid microextraction coupled with HPLC for the determination of trans,trans-muconic acid in human urine sample. J Sep Sci 2021; 44:3126-3136. [PMID: 34114310 DOI: 10.1002/jssc.202100044] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 06/05/2021] [Accepted: 06/09/2021] [Indexed: 12/26/2022]
Abstract
trans,trans-Muconic acid has been widely used as a biomarker in biological monitoring of benzene-exposed workers during routine occupational health services. In the present study, a novel microextraction technique, in-syringe ionic liquid-dispersive liquid-liquid microextraction, was implemented for preconcentration of trans,trans-muconic acid followed by analytical determination by high-performance liquid chromatography with ultraviolet detection. Moreover, the important variables affecting the performance of applied microextraction technique including needle diameter, volume of the spiked sample, volume of the ionic liquid, salt addition, rotation speed of centrifugation, centrifuge time, and ultrasonic time were optimized by experimental design. A good linear relationship was observed at the range of 0.032-10 μg/mL between the peak area and the concentration levels (R2 = 0.9997). The limit of detection and extraction recovery for trans,trans-muconic acid were 0.011 μg/mL and >96.2%, respectively. This method provided easy and rapid analysis of low amounts of trans,trans-muconic acid in human urine with simple equipment.
Collapse
Affiliation(s)
- Sepideh Abbaszadeh
- Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Saeed Yousefinejad
- Department of Occupational Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Saeed Jafari
- Department of Occupational Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Esmaeel Soleimani
- Department of Occupational Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
15
|
Butreddy A, Bandari S, Repka MA. Quality-by-design in hot melt extrusion based amorphous solid dispersions: An industrial perspective on product development. Eur J Pharm Sci 2021; 158:105655. [PMID: 33253883 PMCID: PMC7855693 DOI: 10.1016/j.ejps.2020.105655] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 11/21/2020] [Accepted: 11/23/2020] [Indexed: 02/06/2023]
Abstract
An industrially feasible approach to overcome the solubility and bioavailability limitations of poorly soluble active pharmaceutical ingredients is the development of amorphous solid dispersions (ASDs) using hot-melt extrusion (HME) technique. The application of Quality by Design (QbD) had a profound impact on the development of HME-based ASDs. The formulation and process optimization of ASDs manufactured via HME techniques require an understanding of critical quality attributes, critical material attributes, critical process parameters, risk assessment tools, and experimental designs. The knowledge gained from each of these QbD elements helps ensure the consistency of product quality. The selection and implementation of appropriate Design of Experiments (DoE) methodology to screen and optimize the formulation and process variables remain a major challenge. This review provides a comprehensive overview on QbD concepts in HME-based ASDs with an emphasis on DoE methodologies. Further, the information provided in this review can assist researchers in selecting a suitable design with optimal experimental conditions. Specifically, this review has focused on the prediction of drug-polymer miscibility, the elements and sequence of QbD, and various screening and optimization designs, to provide insights into the formulation and process variables that are encountered routinely in the production of HME-based ASDs.
Collapse
Affiliation(s)
- Arun Butreddy
- Department of Pharmaceutics and Drug Delivery, School of Pharmacy, The University of Mississippi, University, MS 38677, USA
| | - Suresh Bandari
- Department of Pharmaceutics and Drug Delivery, School of Pharmacy, The University of Mississippi, University, MS 38677, USA
| | - Michael A Repka
- Department of Pharmaceutics and Drug Delivery, School of Pharmacy, The University of Mississippi, University, MS 38677, USA; Pii Center for Pharmaceutical Technology, The University of Mississippi, University, MS 38677, USA.
| |
Collapse
|
16
|
A green analytical method for the analysis of polycyclic aromatic hydrocarbons in oral fluids from crack smokers. Bioanalysis 2020; 12:1711-1724. [PMID: 33275040 DOI: 10.4155/bio-2020-0251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Aim: Develop and validate a method of solid-phase microextraction (SPME) and liquid chromatography to investigate three major polycyclic aromatic hydrocarbons (PAHs) in oral fluid. Results/Methodology: The extraction phase was exposed to 1.5 ml of diluted oral fluid under stirring at 1000 rpm for 60 min, at 70°C. Then, it was immersed in 200 μl of acetonitrile for 10 min at 25°C for desorption of the analytes. Linearity, absolute recovery, and inter- and intra-assay relative standard deviations and relative errors were 50-300 ng.ml-1, ≥24% and ≤15% for all analytes, respectively. A full factorial design was used to SPME optimization. Discussion/Conclusion: The method is suitable for the exploratory analysis of some PAHs in the oral fluid of crack smokers.
Collapse
|
17
|
Malvar JL, Santos JL, Martín J, Aparicio I, Alonso E. Comparison of ultrasound-assisted extraction, QuEChERS and selective pressurized liquid extraction for the determination of metabolites of parabens and pharmaceuticals in sludge. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104987] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
18
|
Marrubini G, Dugheri S, Cappelli G, Arcangeli G, Mucci N, Appelblad P, Melzi C, Speltini A. Experimental designs for solid-phase microextraction method development in bioanalysis: A review. Anal Chim Acta 2020; 1119:77-100. [DOI: 10.1016/j.aca.2020.04.012] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 04/03/2020] [Accepted: 04/04/2020] [Indexed: 12/28/2022]
|
19
|
Dugheri S, Mucci N, Bonari A, Marrubini G, Cappelli G, Ubiali D, Campagna M, Montalti M, Arcangeli G. Solid phase microextraction techniques used for gas chromatography: a review. ACTA CHROMATOGR 2020. [DOI: 10.1556/1326.2018.00579] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
In the last decade, the development and adoption of greener and sustainable microextraction techniques have been proved to be an effective alternative to classical sample preparation procedures. In this review, 10 commercially available solid-phase microextraction systems are presented, with special attention to the appraisal of their analytical, bioanalytical, and environmental engineering. This review provides an overview of the challenges and achievements in the application of fully automated miniaturized sample preparation methods in analytical laboratories. Both theoretical and practical aspects of these environment-friendly preparation approaches are discussed. The application of chemometrics in method development is also discussed. We are convinced that green analytical chemistry will be really useful in the years ahead. The application of cheap, fast, automated, “clever”, and environmentally safe procedures to environmental, clinical, and food analysis will improve significantly the quality of the analytical data.
Collapse
Affiliation(s)
- Stefano Dugheri
- 1 Industrial Hygiene and Toxicology Laboratory, Careggi University Hospital, Florence, Italy
| | - Nicola Mucci
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Alessandro Bonari
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | | | - Giovanni Cappelli
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Daniela Ubiali
- 3 Department of Drug Sciences, University of Pavia, Pavia, Italy
| | - Marcello Campagna
- 4 Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| | - Manfredi Montalti
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Giulio Arcangeli
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| |
Collapse
|
20
|
Simultaneous pressurized liquid extraction and clean-up for the determination of metabolites in complex environmental solid matrices. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104370] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
21
|
Optimization by experimental design of headspace sorptive extraction and solid-phase microextraction for the determination of terpenes in spices. FOOD ANAL METHOD 2019. [DOI: 10.1007/s12161-019-01622-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
22
|
Review of Ionic Liquids in Microextraction Analysis of Pesticide Residues in Fruit and Vegetable Samples. Chromatographia 2019. [DOI: 10.1007/s10337-019-03818-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
23
|
Cárdenas-Soracá DM, Tucca FI, Mardones-Peña CA, Barra-Ríos RO. Development of an analytical methodology for the determination of organochlorine pesticides by ethylene-vinyl acetate passive samplers in marine surface waters based on ultrasound-assisted solvent extraction followed with headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry. J Chromatogr A 2019; 1605:360341. [DOI: 10.1016/j.chroma.2019.06.062] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 06/27/2019] [Accepted: 06/29/2019] [Indexed: 10/26/2022]
|
24
|
Balsini P, Parastar H. Development of multi‐response optimization and quadratic calibration curve for determination of ten pesticides in complex sample matrices using QuEChERS dispersive liquid–liquid microextraction followed by gas chromatography. J Sep Sci 2019; 42:3553-3562. [DOI: 10.1002/jssc.201900823] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2019] [Revised: 09/29/2019] [Accepted: 09/30/2019] [Indexed: 01/20/2023]
Affiliation(s)
- Parvaneh Balsini
- Department of ChemistrySharif University of Technology Tehran Iran
| | - Hadi Parastar
- Department of ChemistrySharif University of Technology Tehran Iran
| |
Collapse
|
25
|
Abdollahi F, Taheri A, Shahmari M. Application of selective solid-phase extraction using a new core-shell-shell magnetic ion-imprinted polymer for the analysis of ultra-trace mercury in serum of gallstone patients. SEP SCI TECHNOL 2019. [DOI: 10.1080/01496395.2019.1651337] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
| | - Alireza Taheri
- Department of Chemistry, Islamic Azad University, Ilam, Iran
| | - Mahtab Shahmari
- Department of Food and Drug, Faculty of Medicine, Ilam University of Medical Sciences, Ilam, Iran
| |
Collapse
|
26
|
Bajer T, Šulc J, Ventura K, Bajerová P. Design of the Extraction Process for Characterization of Volatile Profile of Stem Wood by Solid-Phase Microextraction. Nat Prod Commun 2019. [DOI: 10.1177/1934578x19842721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
A method for isolation of volatile compounds from samples of stem wood by solid-phase microextraction was developed. The extraction method was optimized using a central composite design approach. Extraction temperature and extraction time were optimized in the ranges of 40°C to 120°C and 10 to 90 minutes, respectively. Final extraction method was combined with GC-MS for separation and identification of volatile components of wood samples of seven tree species, commonly occurring in Central Europe. All of them were deciduous (acacia, alder, beech, elm, larch, maple, and oak). In total 185 organic compounds were identified in volatile profiles of all the samples by the developed method. To facilitate the evaluation of the suitability of the proposed method for extraction of different compound types, all identified compounds were categorized into 16 groups. Percentage of compound groups in volatile profiles of individual wood samples shows that the developed method is suitable for evaluation of a wide range of volatile components from stem wood.
Collapse
Affiliation(s)
- Tomáš Bajer
- Department of Analytical Chemistry, Studentská 573, University of Pardubice, 532 10 Pardubice, Czech Republic
| | - Jakub Šulc
- Department of Analytical Chemistry, Studentská 573, University of Pardubice, 532 10 Pardubice, Czech Republic
| | - Karel Ventura
- Department of Analytical Chemistry, Studentská 573, University of Pardubice, 532 10 Pardubice, Czech Republic
| | - Petra Bajerová
- Department of Analytical Chemistry, Studentská 573, University of Pardubice, 532 10 Pardubice, Czech Republic
| |
Collapse
|
27
|
Nanostructured polyaniline based pipette tip solid phase extraction coupled with high-performance liquid chromatography for the selective determination of trace levels of three sulfonamides in honey and milk samples with the aid of experimental design methodology. Microchem J 2019. [DOI: 10.1016/j.microc.2019.02.020] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
28
|
Seidi S, Alavi L, Jabbari A. Dispersed Solidified Fine Droplets Based on Sonication of a Low Melting Point Deep Eutectic Solvent: a Novel Concept for Fast and Efficient Determination of Cr(VI) in Urine Samples. Biol Trace Elem Res 2019; 188:353-362. [PMID: 30043285 DOI: 10.1007/s12011-018-1438-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Accepted: 07/09/2018] [Indexed: 11/28/2022]
Abstract
Cr(VI) has carcinogenic effects, so determination of trace amount of chromium in human body such as urine has a great deal of importance. In this work, a novel microextraction method was developed based on solidification of dispersed fine droplets (SDFD) of a low melting point deep eutectic solvent (DES), produced with the aid of sonication, for fast and efficient determination of Cr(VI) in urine samples. Cr(VI) contents of the human urine samples were first complexed using 1,5-diphenylcarbazone at pH ≈ 2.0 and then extracted by the method. A cloudy solution was achieved by the sonication of a microliter volume of a new water-immiscible DES consisting of benzyltriphenylphosphonium bromide (BTPPB) and phenol. Low freezing point of DES makes it possible to use simple, precise, and fast collection of the extraction phase by solidification and the subsequent centrifugation. Finally, the sedimented phase was diluted with methanol and analyzed by electrothermal atomic absorption spectrometry (ETAAS). The influences of the main factors on the efficiency of the procedure were investigated by a four-factor central composite design (CCD). Under the optimum conditions, the calibration curve was linear within the range of 10-1000 ng L-1. The intra- and inter-day RSD% values of 2.6 and 4.7% were obtained at the concentration of 50.0 ng L-1, respectively. The limits of detection (LOD) and quantification (LOQ) were calculated as 2.0 and 7.0 ng L-1, respectively. Moreover, compared to the other approaches, the proposed method presented better or comparable analytical performance and provided accurate, precise, and reliable results for trace analysis of Cr(VI) in urine samples.
Collapse
Affiliation(s)
- Shahram Seidi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran, Iran.
| | - Leila Alavi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran, Iran
| | - Ali Jabbari
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran, Iran
| |
Collapse
|
29
|
Alsharif AMA, Choo YM, Tan GH. Detection of Five Mycotoxins in Different Food Matrices in the Malaysian Market by Using Validated Liquid Chromatography Electrospray Ionization Triple Quadrupole Mass Spectrometry. Toxins (Basel) 2019; 11:toxins11040196. [PMID: 30935130 PMCID: PMC6520768 DOI: 10.3390/toxins11040196] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Revised: 03/28/2019] [Accepted: 03/29/2019] [Indexed: 11/16/2022] Open
Abstract
Mycotoxins are common food contaminants which cause poisoning and severe health risks to humans and animals. The present study applied chemometric approach in liquid chromatography-tandem mass spectrometry (LC-MS/MS) optimization for simultaneous determination of mycotoxins, i.e., aflatoxins B1, B2, G1, and G2, and ochratoxin A. The validated quick, easy, cheap, effective, rugged, and safe (QuEChERS)-LC-MS/MS method was used to study the occurrence of mycotoxins in 120 food matrices. The recovery ranges from 81.94% to 101.67% with relative standard deviation (RSD) lesser than 11%. Through the developed method, aflatoxins were detected in raisin, pistachio, peanut, wheat flour, spice, and chili samples with concentration ranges from 0.45 to 16.93 µg/kg. Trace concentration of ochratoxin A was found in wheat flour and peanut samples which ranged from 1.2 to 3.53 µg/kg. Some of the tested food samples contained mycotoxins of above the European legal maximum limit.
Collapse
Affiliation(s)
- Ali Mohamed Ali Alsharif
- Department of Chemistry, Faculty of Science, University of Mala, Kuala Lumpur 50603, Malaysia.
- Arab Centre for Desertification and Development of Saharian Societies, Murzuk 999116, Libya.
| | - Yeun-Mun Choo
- Department of Chemistry, Faculty of Science, University of Mala, Kuala Lumpur 50603, Malaysia.
| | - Guan-Huat Tan
- Department of Chemistry, Faculty of Science, University of Mala, Kuala Lumpur 50603, Malaysia.
| |
Collapse
|
30
|
Alsharif AMA, Choo YM, Tan GH, Abdulra’uf LB. Determination of Mycotoxins Using Hollow Fiber Dispersive Liquid–Liquid–Microextraction (HF-DLLME) Prior to High-Performance Liquid Chromatography – Tandem Mass Spectrometry (HPLC - MS/MS). ANAL LETT 2019. [DOI: 10.1080/00032719.2019.1587766] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Affiliation(s)
- Ali Mohamed Ali Alsharif
- Department of Chemistry, Faculty of Science, University of Malaya, Kuala Lumpur , Malaysia
- Arab Centre for Desertification and Development of Saharian Societies, Murzuk, Libya
| | - Yeun-Mun Choo
- Department of Chemistry, Faculty of Science, University of Malaya, Kuala Lumpur , Malaysia
| | - Guan Huat Tan
- Department of Chemistry, Faculty of Science, University of Malaya, Kuala Lumpur , Malaysia
| | - Lukman Bola Abdulra’uf
- Department of Chemistry, College of Pure and Applied Sciences, Kwara State University, Malete, Nigeria
| |
Collapse
|
31
|
Bezerra MA, Ferreira SLC, Novaes CG, dos Santos AMP, Valasques GS, da Mata Cerqueira UMF, dos Santos Alves JP. Simultaneous optimization of multiple responses and its application in Analytical Chemistry – A review. Talanta 2019; 194:941-959. [DOI: 10.1016/j.talanta.2018.10.088] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Revised: 10/26/2018] [Accepted: 10/26/2018] [Indexed: 01/05/2023]
|
32
|
Development, Optimization, and Validation of the HS-SPME/GC-MS Method for the Residual Determination of Menthol in Fish. FOOD ANAL METHOD 2019. [DOI: 10.1007/s12161-019-01467-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
33
|
Fahimirad B, Rajabi M, Elhampour A. A rapid and simple extraction of anti-depressant drugs by effervescent salt-assisted dispersive magnetic micro solid-phase extraction method using new adsorbent Fe3O4@SiO2@N3. Anal Chim Acta 2019; 1047:275-284. [DOI: 10.1016/j.aca.2018.10.028] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Revised: 09/18/2018] [Accepted: 10/12/2018] [Indexed: 01/05/2023]
|
34
|
Sahebi H, Pourmortazavi SM, Zandavar H, Mirsadeghi S. Chitosan grafted onto Fe3O4@poly(N-vinylcaprolactam) as a new sorbent for detecting Imatinib mesylate in biosamples using UPLC-MS/MS. Analyst 2019; 144:7336-7350. [DOI: 10.1039/c9an01654f] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Fe3O4 nanoparticles with chitosan grafted onto poly(N-vinylcaprolactam) copolymers are synthesized and showed dual sensitivity to temperature and pH.
Collapse
Affiliation(s)
- Hamed Sahebi
- Department of Chemistry
- Faculty of Science
- Islamic Azad University Central Tehran Branch
- Iran
| | | | - Hamed Zandavar
- Faculty of Chemistry and Chemical Engineering
- Malek Ashtar University of Technology
- Tehran
- Iran
| | - Somayeh Mirsadeghi
- Endocrinology and Metabolism Research Center
- Endocrinology and Metabolism Clinical Sciences Institute
- Tehran University of Medical Sciences
- Tehran
- Iran
| |
Collapse
|
35
|
Applications and opportunities of experimental design for the dispersive liquid–liquid microextraction method – A review. Talanta 2018; 190:335-356. [DOI: 10.1016/j.talanta.2018.08.002] [Citation(s) in RCA: 89] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2018] [Revised: 07/31/2018] [Accepted: 08/01/2018] [Indexed: 12/22/2022]
|
36
|
Abril C, Santos JL, Malvar JL, Martín J, Aparicio I, Alonso E. Determination of perfluorinated compounds, bisphenol A, anionic surfactants and personal care products in digested sludge, compost and soil by liquid-chromatography-tandem mass spectrometry. J Chromatogr A 2018; 1576:34-41. [DOI: 10.1016/j.chroma.2018.09.028] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Revised: 07/17/2018] [Accepted: 09/15/2018] [Indexed: 12/21/2022]
|
37
|
Zare F, Jannesar R, Purkait MK, Ghaedi M. Ultrasound-assisted dispersive micro-solid-phase extraction using hydrophobic thiolated ionic liquids immobilized on gold nanoparticles for the preconcentration and determination of amino acids in human plasma samples. SEPARATION SCIENCE PLUS 2018. [DOI: 10.1002/sscp.201800029] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Fahimeh Zare
- Department of Chemistry; Faculty of Sciences; Yasouj University; Yasouj Iran
| | | | - M. K. Purkait
- Department of Chemical Engineering; Indian Institute of Technology Guwahati; Guwahati Assam India
| | - Mehrorang Ghaedi
- Department of Chemistry; Faculty of Sciences; Yasouj University; Yasouj Iran
| |
Collapse
|
38
|
Abril C, Martín J, Malvar JL, Santos JL, Aparicio I, Alonso E. Dispersive liquid-liquid microextraction as a new clean-up procedure for the determination of parabens, perfluorinated compounds, UV filters, biocides, surfactants, and plasticizers in root vegetables. Anal Bioanal Chem 2018; 410:5155-5163. [PMID: 29947903 DOI: 10.1007/s00216-018-1165-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2018] [Revised: 03/16/2018] [Accepted: 05/26/2018] [Indexed: 12/25/2022]
Abstract
An analytical method based on ultrasound-assisted extraction and dispersive liquid-liquid microextraction (DLLME) clean-up has been developed and validated for the determination of 31 emerging pollutants in root vegetables. The target compounds were four preservatives, six perfluoroalkyl compounds, six UV filters, two biocides, eight anionic surfactants, three nonionic surfactants, and two plasticizers. The type and volume of the extraction solvent, those of the disperser solvent, the pH and NaCl content of the DLLME aqueous phase, the amount of sample, and the sonication time were optimized. Box-Behnken experimental design was applied to select the best extraction conditions. Matrix-matched calibration curves were used for quantification. Four internal standards were used to compensate for residual matrix effects. Good linearity (R2 > 0.990), accuracies (expressed as the relative recovery) of >82%, and precisions (expressed as the relative standard deviation) of <18% were achieved. Method quantification limits (MQLs), calculated from spiked samples as the concentrations corresponding to signal-to-noise ratios of 10, were in the range 0.1-25 ng g-1 dry weight (d.w.). MQL values for 26 of the 31 target compounds were lower than 5 ng g-1 d.w. The method was successfully applied to determine the target pollutants in carrots, potatoes, and turnips from a local market. To the best of our knowledge, the proposed method constitutes the first application of DLLME as a clean-up procedure for the multiresidue determination of emerging pollutants in vegetables. The method affords similar recoveries and method detection limits to previously reported methods but requires smaller solvent volumes and sample amounts and is less expensive.
Collapse
Affiliation(s)
- Concepción Abril
- Department of Analytical Chemistry, Escuela Politécnica Superior, University of Seville, C/ Virgen de África, 7, 41011, Seville, Spain
| | - Julia Martín
- Department of Analytical Chemistry, Escuela Politécnica Superior, University of Seville, C/ Virgen de África, 7, 41011, Seville, Spain
| | - José Luis Malvar
- Department of Analytical Chemistry, Escuela Politécnica Superior, University of Seville, C/ Virgen de África, 7, 41011, Seville, Spain
| | - Juan Luis Santos
- Department of Analytical Chemistry, Escuela Politécnica Superior, University of Seville, C/ Virgen de África, 7, 41011, Seville, Spain
| | - Irene Aparicio
- Department of Analytical Chemistry, Escuela Politécnica Superior, University of Seville, C/ Virgen de África, 7, 41011, Seville, Spain.
| | - Esteban Alonso
- Department of Analytical Chemistry, Escuela Politécnica Superior, University of Seville, C/ Virgen de África, 7, 41011, Seville, Spain
| |
Collapse
|
39
|
Akhoundzadeh H, Gholami A, Masoum S, Moazeni-Pourasil RS. Headspace Solid-Phase Microextraction GC–MS for Rapid Rice Aroma Analysis Using Optimization Tools. Chromatographia 2018. [DOI: 10.1007/s10337-018-3517-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
40
|
Kamari K, Taheri A. Preparation and evaluation of magnetic core–shell mesoporous molecularly imprinted polymers for selective adsorption of amitriptyline in biological samples. J Taiwan Inst Chem Eng 2018. [DOI: 10.1016/j.jtice.2018.02.031] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
41
|
Zare F, Razmi M. Ultrasound-assisted low-density-solvent-based solvent-demulsified dispersive liquid-liquid microextraction for the quantification of amino acids in biological samples. SEPARATION SCIENCE PLUS 2018. [DOI: 10.1002/sscp.201700032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Fahimeh Zare
- Young Researchers and Elite Club, Marvdasht Branch; Islamic Azad University; Marvdasht Iran
| | - Mahdi Razmi
- Young Researchers and Elite Club, Marvdasht Branch; Islamic Azad University; Marvdasht Iran
| |
Collapse
|
42
|
Yen FL, Wang SW, Cheng HL, Chen KL, Chen YL. Determination of Saikosaponins in Bupleuri Radix by Micellar Electrokinetic Chromatography with Experimental Design. ANAL LETT 2018. [DOI: 10.1080/00032719.2017.1392548] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Affiliation(s)
- Feng-Lin Yen
- Department of Fragrance and Cosmetic Science, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Shih-Wei Wang
- Department of Medicine, Mackay Medical College, Taipei, Taiwan
| | - Hui-Ling Cheng
- Biomedical Technology and Device Research Laboratories, Pharmaceutical Optimization Technology Division, Industrial Technology Research Institute, Hsinchu, Taiwan
| | - Kuan-Ling Chen
- Department of Fragrance and Cosmetic Science, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Yen-Ling Chen
- Department of Fragrance and Cosmetic Science, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Marine Biotechnology and Resources, College of Marine Sciences, National Sun Yat-Sen University, Kaohsiung, Taiwan
- Research Center for Environmental Medical, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| |
Collapse
|
43
|
A yolk shell Fe3O4 @PA-Ni@Pd/Chitosan nanocomposite -modified carbon ionic liquid electrode as a new sensor for the sensitive determination of fluconazole in pharmaceutical preparations and biological fluids. J Mol Liq 2018. [DOI: 10.1016/j.molliq.2018.01.019] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
44
|
Aparicio I, Martín J, Abril C, Santos JL, Alonso E. Determination of household and industrial chemicals, personal care products and hormones in leafy and root vegetables by liquid chromatography-tandem mass spectrometry. J Chromatogr A 2018; 1533:49-56. [DOI: 10.1016/j.chroma.2017.12.011] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Revised: 11/22/2017] [Accepted: 12/05/2017] [Indexed: 12/17/2022]
|
45
|
Khodadoust S, Nasiriani T, Zeraatpisheh F. Preparation of a magnetic molecularly imprinted polymer for the selective adsorption of chlordiazepoxide and its determination by central composite design optimized HPLC. NEW J CHEM 2018. [DOI: 10.1039/c8nj02643b] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Core–shell magnetic molecularly imprinted polymer nanoparticles (MMIP-NPs) were prepared and applied in the extraction of chlordiazepoxide from various samples.
Collapse
Affiliation(s)
- Saeid Khodadoust
- Department of Chemistry
- Behbahan Khatam Alanbia University of Technology
- Behbahan
- Iran
| | - Tahereh Nasiriani
- Department of Chemistry
- Behbahan Khatam Alanbia University of Technology
- Behbahan
- Iran
| | - Fatemeh Zeraatpisheh
- Department of Chemistry
- Behbahan Khatam Alanbia University of Technology
- Behbahan
- Iran
| |
Collapse
|
46
|
Extraction and physicochemical properties of polysaccharides from Ziziphus Jujuba cv. Muzao by ultrasound-assisted aqueous two-phase extraction. Int J Biol Macromol 2017; 108:541-549. [PMID: 29233708 DOI: 10.1016/j.ijbiomac.2017.12.042] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2017] [Revised: 11/30/2017] [Accepted: 12/06/2017] [Indexed: 12/20/2022]
Abstract
In this paper, ultrasound-assisted aqueous two-phase extraction (UAATPE) performed via a one-step procedure was applied to extract polysaccharides from Ziziphus Jujuba cv. Muzao. Using an ethanol/ammonium sulfate system as a multiphase solvent, effects of UAATPE on extraction of ZMP, such as solvent-to-material ratio, composition of aqueous two-phase system, and extraction time and temperature, were investigated using response surface methodology on basis of results of single-factor experiment. The final optimal conditions were ATPS composition: 29% ethanol and 15% (NH4)2SO4, extraction time: 38min, extraction temperature: 48°C, solvent-to-material ratio: 30, and microwave power: 70W. Under these conditions, the experimental extraction yield was 8.18%. Chemical analysis revealed that ZMP were composed of rhamnose, arabinose, xylose, mannose, glucose, galactose, and galacturonic acid, at a ratio of 1.46:2.47:2.27:1.12:1.00:1.57:5.40, respectively. The structures were also characterized with UV, FTIR, and SEM. The DPPH and ABTS radical scavenging activities showed ZMP had moderately antioxidant activity.
Collapse
|
47
|
Hemmati M, Asghari A, Ghaedi M, Rajabi M. Chemometric assisted sonochemical dyes adsorption in ternary solutions onto Cu nanowires loaded on activated carbon. J Taiwan Inst Chem Eng 2017. [DOI: 10.1016/j.jtice.2017.03.025] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
48
|
Efficient and clean pre-concentration of ultra-trace calcium channel blockers from biological matrices via a hyphenated procedure of two sequential dispersive solid/liquid phase microextractions. Anal Chim Acta 2017; 960:138-150. [DOI: 10.1016/j.aca.2017.01.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2016] [Revised: 12/31/2016] [Accepted: 01/02/2017] [Indexed: 12/17/2022]
|
49
|
Cepeda-Vázquez M, Blumenthal D, Camel V, Rega B. Multivariate optimization of headspace trap for furan and furfural simultaneous determination in sponge cake. Talanta 2017; 164:708-715. [DOI: 10.1016/j.talanta.2016.10.073] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 10/16/2016] [Accepted: 10/18/2016] [Indexed: 10/20/2022]
|
50
|
Behbahani M, Omidi F, Kakavandi MG, Hesam G. Selective and sensitive determination of silver ions at trace levels based on ultrasonic‐assisted dispersive solid‐phase extraction using ion‐imprinted polymer nanoparticles. Appl Organomet Chem 2017. [DOI: 10.1002/aoc.3758] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Mohammad Behbahani
- Research Center for Environmental Determinants of Health (RCEDH)Kermanshah University of Medical Sciences Kermanshah Iran
| | - Fariborz Omidi
- Department of Occupational Health Engineering, School of Public HealthTehran University of Medical Sciences Tehran Iran
| | | | - Ghasem Hesam
- Department of Occupational Health Engineering, School of Public HealthShahroud University of Medical Sciences Shahroud Iran
| |
Collapse
|