1
|
Salimian Rizi F, Talebi S, Manshadi MKD, Mohammadi M. Separation of bacteria smaller than 4 µm from other blood components using insulator-based dielectrophoresis: numerical simulation approach. Biomech Model Mechanobiol 2023; 22:825-836. [PMID: 36787033 DOI: 10.1007/s10237-022-01683-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 12/28/2022] [Indexed: 02/15/2023]
Abstract
Bloodstream infection (BSI) is a life-threatening infection that causes more than 80,000 deaths and more than 500,000 infections annually in North America. The rapid diagnosis of infection reduces BSI mortality. We proposed bacterial enrichment and separation approach in the current work that may reduce culturing time and accelerate the diagnosis of infection. Over the last two decades, multiple separation methods have been developed, and among these methods, insulator-based dielectrophoresis (iDEP) is considered a powerful technique for separating biological particles. Bacterial separation in the blood is challenging due to the presence of other blood cells, such as white blood cells, red blood cells, and platelets. In the present study, a model is presented which is capable of blood cells separation and directing each cell to a specific outlet using continuous flows of particles with sizes larger than 8 µm, 8-4 µm, and smaller than 4 µm. Compared to other methods, such as filtration, the main advantage of this model is that particles larger than 8 µm are separated from the flow before other particles, which prevents the accumulation of particles in the channel. The outcomes of simulations demonstrated that the factors such as applied voltage and channel dimensions significantly affect the separation efficiency. If these values are properly selected (for example voltage of 70 V that was causing an electric field of 200 V/cm), the proposed model can completely (100%) separate particles larger than 8 µm and smaller than 4 µm (8-4 µm particles separation efficiency is 95%).
Collapse
Affiliation(s)
| | - Shahram Talebi
- Mechanical Engineering Department, Yazd University, Yazd, Iran.
| | | | - Mehdi Mohammadi
- Department of Biological Sciences, University of Calgary, Calgary, AB, T2N 1N4, Canada.
- Department of Biomedical Engineering, University of Calgary, Calgary, AB, T2N 1N4, Canada.
| |
Collapse
|
2
|
Zhao K, Wei Y, Dong J, Zhao P, Wang Y, Pan X, Wang J. Separation and characterization of microplastic and nanoplastic particles in marine environment. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2022; 297:118773. [PMID: 34974085 DOI: 10.1016/j.envpol.2021.118773] [Citation(s) in RCA: 40] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 12/16/2021] [Accepted: 12/28/2021] [Indexed: 06/14/2023]
Abstract
Microplastics (<5 mm) are divided into primary and secondary microplastics, which are further degraded into nanoplastics. The microplastic particles are widely distributed in marine environment, terrestrial ecosystem and biological organism, leading to damages to whole environmental system. Microplastics are not only difficult to degrade, but also able to adsorb pollutants. Due to the tiny size and various properties, the separation and characterization of microplastic particles has become more and more challenging. This review introduces the sources and destinations of the microplastic particles and summarizes the general methods for the sorting and characterization of microplastics, especially the manipulation of microplastic particles on microfluidic chip, showing possibility to deal with smaller nanoplastic particles over traditional methods. This review focuses on studies of the size-based separation and property-dependent characterization of microplastics in marine environment by utilizing the microfluidic chip device.
Collapse
Affiliation(s)
- Kai Zhao
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, 116026, Dalian, China; Department of Information Science and Technology, Dalian Maritime University, 116026, Dalian, China
| | - Yunman Wei
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, 116026, Dalian, China; Department of Information Science and Technology, Dalian Maritime University, 116026, Dalian, China
| | - Jianhong Dong
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, 116026, Dalian, China; Department of Information Science and Technology, Dalian Maritime University, 116026, Dalian, China
| | - Penglu Zhao
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, 116026, Dalian, China; Department of Information Science and Technology, Dalian Maritime University, 116026, Dalian, China
| | - Yuezhu Wang
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, 116026, Dalian, China; Department of Environmental Sciences and Engineering, Dalian Maritime University, 116026, Dalian, China
| | - Xinxiang Pan
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, 116026, Dalian, China; Department of Maritime, Guangdong Ocean University, 524000, Zhanjiang, China
| | - Junsheng Wang
- Liaoning Key Laboratory of Marine Sensing and Intelligent Detection, Dalian Maritime University, 116026, Dalian, China; Department of Information Science and Technology, Dalian Maritime University, 116026, Dalian, China.
| |
Collapse
|
3
|
Lapizco-Encinas BH. The latest advances on nonlinear insulator-based electrokinetic microsystems under direct current and low-frequency alternating current fields: a review. Anal Bioanal Chem 2021; 414:885-905. [PMID: 34664103 DOI: 10.1007/s00216-021-03687-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Revised: 09/17/2021] [Accepted: 09/21/2021] [Indexed: 12/11/2022]
Abstract
This review article presents an overview of the evolution of the field of insulator-based dielectrophoresis (iDEP); in particular, it focuses on insulator-based electrokinetic (iEK) systems stimulated with direct current and low-frequency(< 1 kHz) AC electric fields. The article covers the surge of iDEP as a research field where many different device designs were developed, from microchannels with arrays of insulating posts to devices with curved walls and nano- and micropipettes. All of these systems allowed for the manipulation and separation of a wide array of particles, ranging from macromolecules to microorganisms, including clinical and biomedical applications. Recent experimental reports, supported by important theoretical studies in the field of physics and colloids, brought attention to the effects of electrophoresis of the second kind in these systems. These recent findings suggest that DEP is not the main force behind particle trapping, as it was believed for the last two decades. This new research suggests that particle trapping, under DC and low-frequency AC potentials, mainly results from a balance between electroosmotic and electrophoretic effects (linear and nonlinear); although DEP is present in these systems, it is not a dominant force. Considering these recent studies, it is proposed to rename this field from DC-iDEP to DC-iEK (and low-frequency AC-iDEP to low-frequency AC-iEK). Whereas much research is still needed, this is an exciting time in the field of microscale EK systems, as these new findings seem to explain the challenges with modeling particle migration and trapping in iEK devices, and provide perhaps a better understanding of the mechanisms behind particle trapping.
Collapse
Affiliation(s)
- Blanca H Lapizco-Encinas
- Microscale Bioseparations Laboratory and Biomedical Engineering Department, Rochester Institute of Technology, Institute Hall (Bldg. 73), Room 3103, 160 Lomb Memorial Drive, Rochester, NY, 14623-5604, USA.
| |
Collapse
|
4
|
Perez‐Gonzalez VH. Particle trapping in electrically driven insulator-based microfluidics: Dielectrophoresis and induced-charge electrokinetics. Electrophoresis 2021; 42:2445-2464. [PMID: 34081787 PMCID: PMC9291494 DOI: 10.1002/elps.202100123] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 05/29/2021] [Accepted: 06/01/2021] [Indexed: 12/31/2022]
Abstract
Electrokinetically driven insulator‐based microfluidic devices represent an attractive option to manipulate particle suspensions. These devices can filtrate, concentrate, separate, or characterize micro and nanoparticles of interest. Two decades ago, inspired by electrode‐based dielectrophoresis, the concept of insulator‐based dielectrophoresis (iDEP) was born. In these microfluidic devices, insulating structures (i.e., posts, membranes, obstacles, or constrictions) built within the channel are used to deform the spatial distribution of an externally generated electric field. As a result, particles suspended in solution experience dielectrophoresis (DEP). Since then, it has been assumed that DEP is responsible for particle trapping in these devices, regardless of the type of voltage being applied to generate the electric field—direct current (DC) or alternating current. Recent findings challenge this assumption by demonstrating particle trapping and even particle flow reversal in devices that prevent DEP from occurring (i.e., unobstructed long straight channels stimulated with a DC voltage and featuring a uniform electric field). The theory introduced to explain those unexpected observations was then applied to conventional “DC‐iDEP” devices, demonstrating better prediction accuracy than that achieved with the conventional DEP‐centered theory. This contribution summarizes contributions made during the last two decades, comparing both theories to explain particle trapping and highlighting challenges to address in the near future.
Collapse
|
5
|
Giduthuri AT, Adekanmbi EO, Srivastava SK, Moberly JG. Dielectrophoretic ultra-high-frequency characterization and in silico sorting on uptake of rare earth elements by Cupriavidus necator. Electrophoresis 2020; 42:656-666. [PMID: 33215725 DOI: 10.1002/elps.202000095] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 09/30/2020] [Accepted: 11/13/2020] [Indexed: 12/12/2022]
Abstract
Rare earth elements (REEs) are widely used across different industries due to their exceptional magnetic and electrical properties. In this work, Cupriavidus necator is characterized using dielectrophoretic ultra-high-frequency measurements, typically in MHz range to quantify the properties of cytoplasm in C. necator for its metal uptake/bioaccumulation capacity. Cupriavidus necator, a Gram-negative bacteria strain is exposed to REEs like europium, samarium, and neodymium in this study. Dielectrophoretic crossover frequency experiments were performed on the native C. necator species pre- and post-exposure to the REEs at MHz frequency range. The net conductivity of native C. necator, Cupriavidus europium, Cupriavidus samarium, and Cupriavidus neodymium are 15.95 ± 0.029 μS/cm, 16.15 ± 0.028 μS/cm, 16.05 ± 0.029 μS/cm, 15.61 ± 0.005 μS/cm respectively. The estimated properties of the membrane published by our group are used to develop a microfluidic sorter by modeling and simulation to separate REE absorbed C. necator from the unabsorbed native C. necator species using COMSOL Multiphysics commercial software package v5.5.
Collapse
Affiliation(s)
- Anthony T Giduthuri
- Department of Chemical and Biological Engineering, University of Idaho, Moscow, ID, USA
| | - Ezekiel O Adekanmbi
- Department of Chemical and Biological Engineering, University of Idaho, Moscow, ID, USA
| | - Soumya K Srivastava
- Department of Chemical and Biological Engineering, University of Idaho, Moscow, ID, USA
| | - James G Moberly
- Department of Chemical and Biological Engineering, University of Idaho, Moscow, ID, USA
| |
Collapse
|
6
|
Wang Q, Zhang X, Yin D, Deng J, Yang J, Hu N. A Continuous Cell Separation and Collection Approach on a Microfilter and Negative Dielectrophoresis Combined Chip. MICROMACHINES 2020; 11:mi11121037. [PMID: 33255917 PMCID: PMC7759882 DOI: 10.3390/mi11121037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 11/18/2020] [Accepted: 11/24/2020] [Indexed: 12/12/2022]
Abstract
Cell separation plays an important role in the fields of analytical chemistry and biomedicine. To solve the blockage problem and improve the separation throughput in the traditional microstructure filtration-based separation approach, a continuous cell separation and collection approach via micropost array railing on a microfilter and negative dielectrophoresis combined chip is proposed. By tilting the micropost array at a certain angle, microparticles or cells enter the collection area under micropost array railing. The effects of the inclination angle of the micropost array and the electrode distance on the microparticle collection efficiency were investigated. Based on the optimized microfluidic chip structure, 37- and 16.3-μm particles were collected with 85% and 89% efficiencies, respectively. Additionally, algal cells were separated and collected by using the optimized microchip. The chip also had good separation and collection effects on biological samples, which effectively solved the blockage problem and improved the separation throughput, laying a foundation for subsequent microstructure filtration separation-based research and application.
Collapse
Affiliation(s)
- Qiong Wang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China; (Q.W.); (D.Y.); (J.D.); (J.Y.)
- School of Health and Aging Service, Chongqing City Management College, Chongqing 401331, China
| | - Xiaoling Zhang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China; (Q.W.); (D.Y.); (J.D.); (J.Y.)
- Correspondence: (X.Z.); (N.H.); Tel.: +86-23-6510-2291 (N.H.)
| | - Danfen Yin
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China; (Q.W.); (D.Y.); (J.D.); (J.Y.)
| | - Jinan Deng
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China; (Q.W.); (D.Y.); (J.D.); (J.Y.)
| | - Jun Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China; (Q.W.); (D.Y.); (J.D.); (J.Y.)
| | - Ning Hu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China; (Q.W.); (D.Y.); (J.D.); (J.Y.)
- Correspondence: (X.Z.); (N.H.); Tel.: +86-23-6510-2291 (N.H.)
| |
Collapse
|
7
|
Adekanmbi EO, Giduthuri AT, Carv BA, Counts J, Moberly JG, Srivastava SK. Application of dielectrophoresis towards characterization of rare earth elements biosorption by Cupriavidus necator. Anal Chim Acta 2020; 1129:150-157. [DOI: 10.1016/j.aca.2020.07.042] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 06/05/2020] [Accepted: 07/15/2020] [Indexed: 12/11/2022]
|
8
|
Lee K, Lee J, Ha D, Kim M, Kim T. Low-electric-potential-assisted diffusiophoresis for continuous separation of nanoparticles on a chip. LAB ON A CHIP 2020; 20:2735-2747. [PMID: 32596703 DOI: 10.1039/d0lc00196a] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Nanoparticle separation techniques are of significant importance in nanoscience and nanotechnological applications and different concentration gradients, electric/dielectric forces, flow/pressure fields, and acoustic waves have been intensively investigated. However, precise separation of nanoparticles has many technical challenges in terms of sizes, shapes, and material properties, limiting the separation resolution, capability, applicability, throughput and so on. In this study, we present a microfluidic device for continuous separation of nanoparticles by combining diffusiophoresis (DP) and electrophoresis (EP) to achieve high separation performance. Concentration gradients formed from sodium chloride (NaCl) and potassium acetate (K-acetate) passively drive the diffusiophoretic migration of nanoparticles. Simultaneously, a low electric potential is additionally applied to impose a synergistic effect on nanoparticle migration by size and surface charge, which is called low-electric-potential-assisted DP (LEPDP). Using a LEPDP-based separation device, we demonstrate the separation of nanoparticles having different sizes (diameters of 500, 200, and 50 nm) and under different surface-charge conditions (carboxylated polystyrene, silica, and polylactide). The resulting separation performance exceeded 95%, in terms of size uniformity, which is about two times better than that obtained using DP alone. We also emphasize that the enhancement of separation performance only needs a small voltage (<1 V), thereby demonstrating that our multiphysical approach could be utilized for high-resolution and portable nanoparticle separation on a chip without the side effects associated with high electric fields. Lastly, we ensure that rapid and precise bio/chemical sensing and analysis of various nanosized particles would be envisioned by strategically combining two nonlinear but synergistic migration effects.
Collapse
Affiliation(s)
- Kyunghun Lee
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), 50 UNIST-gil, Ulsan 44919, Republic of Korea.
| | | | | | | | | |
Collapse
|
9
|
Calero V, García-Sánchez P, Ramos A, Morgan H. Electrokinetic biased deterministic lateral displacement: scaling analysis and simulations. J Chromatogr A 2020; 1623:461151. [DOI: 10.1016/j.chroma.2020.461151] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2020] [Revised: 04/12/2020] [Accepted: 04/20/2020] [Indexed: 11/25/2022]
|
10
|
Dielectric Characterization and Separation Optimization of Infiltrating Ductal Adenocarcinoma via Insulator-Dielectrophoresis. MICROMACHINES 2020; 11:mi11040340. [PMID: 32218322 PMCID: PMC7230867 DOI: 10.3390/mi11040340] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 03/20/2020] [Accepted: 03/23/2020] [Indexed: 12/27/2022]
Abstract
The dielectrophoretic separation of infiltrating ductal adenocarcinoma cells (ADCs) from isolated peripheral blood mononuclear cells (PBMCs) in a ~1.4 mm long Y-shaped microfluidic channel with semi-circular insulating constrictions is numerically investigated. In this work, ADCs (breast cancer cells) and PBMCs' electrophysiological properties were iteratively extracted through the fitting of a single-shell model with the frequency-conductivity data obtained from AC microwell experiments. In the numerical computation, the gradient of the electric field required to generate the necessary dielectrophoretic force within the constriction zone was provided through the application of electric potential across the whole fluidic channel. By adjusting the difference in potentials between the global inlet and outlet of the fluidic device, the minimum (effective) potential difference with the optimum particle transmission probability for ADCs was found. The radius of the semi-circular constrictions at which the effective potential difference was swept to obtain the optimum constriction size was also obtained. Independent particle discretization analysis was also conducted to underscore the accuracy of the numerical solution. The numerical results, which were obtained by the integration of fluid flow, electric current, and particle tracing module in COMSOL v5.3, reveal that PBMCs can be maximally separated from ADCs using a DC power source of 50 V. The article also discusses recirculation or wake formation behavior at high DC voltages (>100 V) even when sorting of cells are achieved. This result is the first step towards the production of a supplementary or confirmatory test device to detect early breast cancer non-invasively.
Collapse
|
11
|
Crowther CV, Sanderlin V, Hayes MA, Gile GH. Effects of surface treatments on trapping with DC insulator-based dielectrophoresis. Analyst 2019; 144:7478-7488. [PMID: 31720589 PMCID: PMC6909249 DOI: 10.1039/c9an01186b] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
A central challenge in measuring the biophysical properties of cells with electrokinetic approaches is the assignment of these biophysical properties to specific biological characteristics. Changes in the electrokinetic behavior of cells may come from mutations, altered gene expression levels, post-translation modifications, or environmental effects. Here we assess the electrokinetic behavior of chemically surface-modified bacterial cells in order to gain insight into the biophysical properties that are specifically affected by changes in surface chemistry. Using E. coli as a scaffold, an amine coupling reaction was used to covalently attach glycine, spermine, bovine serum albumin (protein), or 7-amino-4-methyl-3-coumarinylacetic acid (fluorescent dye) to the free carboxylic acid groups on the surface of the cells. These populations, along with unlabeled control cells, were subject to electrokinetic and dielectrophoretic measurements to quantify any changes in the biophysical properties upon alteration. The properties associated with each electrokinetic force are discussed relative to the specific reactant used. We conclude that relatively modest and superficial changes to cell surfaces can cause measurable changes in their biophysical properties.
Collapse
Affiliation(s)
- Claire V Crowther
- School of Molecular Sciences, Arizona State University, Tempe, Arizona, USA.
| | | | | | | |
Collapse
|
12
|
Sonker M, Kim D, Egatz-Gomez A, Ros A. Separation Phenomena in Tailored Micro- and Nanofluidic Environments. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2019; 12:475-500. [PMID: 30699038 DOI: 10.1146/annurev-anchem-061417-125758] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Separations of bioanalytes require robust, effective, and selective migration phenomena. However, due to the complexity of biological matrices such as body fluids or tissue, these requirements are difficult to achieve. The separations field is thus constantly evolving to develop suitable methods to separate biomarkers and fractionate biospecimens for further interrogation of biomolecular content. Advances in the field of microfabrication allow the tailored generation of micro- and nanofluidic environments. These can be exploited to induce interactions and dynamics of biological species with the corresponding geometrical features, which in turn can be capitalized for novel separation approaches. This review provides an overview of several unique separation applications demonstrated in recent years in tailored micro- and nanofluidic environments. These include electrokinetic methods such as dielectrophoresis and electrophoresis, but also rather nonintuitive ratchet separation mechanisms, continuous flow separations, and fractionations such as deterministic lateral displacement, as well as methods employing entropic forces for separation.
Collapse
Affiliation(s)
- Mukul Sonker
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, USA;
- Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Daihyun Kim
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, USA;
- Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Ana Egatz-Gomez
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, USA;
- Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| | - Alexandra Ros
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, USA;
- Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, Arizona 85287, USA
| |
Collapse
|
13
|
Calero V, Garcia-Sanchez P, Honrado C, Ramos A, Morgan H. AC electrokinetic biased deterministic lateral displacement for tunable particle separation. LAB ON A CHIP 2019; 19:1386-1396. [PMID: 30912779 DOI: 10.1039/c8lc01416g] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
We describe a novel particle separation technique that combines deterministic lateral displacement (DLD) with orthogonal electrokinetic forces. DLD is a microfluidic technique for continuous flow particle separation based on size. We describe new tunable devices that use a combination of AC electric fields with DLD to separate particles below the critical diameter. Planar electrodes were integrated into a classical DLD device to produce a force orthogonal to the fluid flow direction. Experiments with 3.0 μm, 1.0 μm and 500 nm diameter microspheres show that at low frequencies (up to 500 Hz) particles oscillate in the direction of the field due to electrophoretic (EP)/electroosmotic (EO) forces. As the frequency of the field increases, the amplitude of these oscillations vanishes and, eventually dielectrophoresis (DEP) becomes the dominant electrokinetic force on the particles (DEP arises from electric field inhomogeneities caused by the presence of the DLD posts). Both mechanisms alter the paths of the particles inside the DLD devices leading to enhanced sorting of particles below the critical diameter of the device.
Collapse
Affiliation(s)
- Victor Calero
- School of Electronics and Computer Science, and Institute for Life Sciences, University of Southampton, UK.
| | | | | | | | | |
Collapse
|
14
|
Adekanmbi EO, Dustin J, Srivastava SK. Electro-osmotic surface effects generation in an electrokinetic-based transport device: A comparison of RF and MW plasma generating sources. Electrophoresis 2019; 40:1573-1579. [PMID: 30762241 DOI: 10.1002/elps.201800464] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Revised: 01/11/2019] [Accepted: 02/05/2019] [Indexed: 11/06/2022]
Abstract
It is a common practice in insulator-based dielectrophoretic separation to use and reuse PDMS-constructed microdevice for an extended period of time while performing biological and technical replicate experiments. This is usually done to rule out any effects of device variation on separation efficiency. Ensuring that all experimental conditions remain the same is critical to the conclusion that can be drawn from such repeated experiments. One important contributing factor to the flow of materials within the device is electro-osmotic velocity, which stems from the surface condition of the device construction materials. In this paper, we present an affordable microwave-based (MESA-Mgen) oxygen plasma cleaner developed for approximately less than $100 using readily obtainable parts from an average local hardware store with no specialized tools. This low-cost room-air microwave plasma generator was designed using an R-4055, 400 W, 2450 MHz half-pint household microwave oven (Sharp®) for exploring the possibility of sealing polydimethylsiloxane (PDMS) devices onto glass with minimal budgetary commitment. Microfluidic channels generated using MESA-Mgen were evaluated for their electro-osmotic velocities while factors including contact angles, storage-solvent, half-way hydrophobicity period were also explored with MESA-Mgen, and the results were compared to those obtained from the commercially available plasma cleaner (COM-PC). These outcomes revealed that the MESA-Mgen induced hydrophilicity and ensured leak-free sealing of PDMS substrates in a manner comparable with the COM-PC.
Collapse
Affiliation(s)
- Ezekiel O Adekanmbi
- Department of Chemical and Materials Engineering, University of Idaho, Moscow, United States
| | - Jeremiah Dustin
- Department of Nuclear Engineering, University of Idaho, Idaho Falls, United States
| | - Soumya K Srivastava
- Department of Chemical and Materials Engineering, University of Idaho, Moscow, United States
| |
Collapse
|
15
|
Yin D, Zhang X, Han X, Yang J, Hu N. Multi-Stage Particle Separation based on Microstructure Filtration and Dielectrophoresis. MICROMACHINES 2019; 10:mi10020103. [PMID: 30708953 PMCID: PMC6412275 DOI: 10.3390/mi10020103] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2018] [Revised: 01/27/2019] [Accepted: 01/29/2019] [Indexed: 11/16/2022]
Abstract
Particle separation is important in chemical and biomedical analysis. Among all particle separation approaches, microstructure filtration which based particles size difference has turned into one of the most commonly methods. By controlling the movement of particles, dielectrophoresis has also been widely adopted in particle separation. This work presents a microfluidic device which combines the advantages of microfilters and dielectrophoresis to separate micro-particles and cells. A three-dimensional (3D) model was developed to calculate the distributions of the electric field gradient at the two filter stages. Polystyrene particles with three different sizes were separated by micropillar array structure by applying a 35-Vpp AC voltage at 10 KHz. The blocked particles were pushed off the filters under the negative dielectrophoretic force and drag force. A mixture of Haematococcus pluvialis cells and Bracteacoccus engadinensis cells with different sizes were also successfully separated by this device, which proved that the device can separate both biological samples and polystyrene particles.
Collapse
Affiliation(s)
- Danfen Yin
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China.
| | - Xiaoling Zhang
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China.
| | - Xianwei Han
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China.
| | - Jun Yang
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China.
| | - Ning Hu
- Key Laboratory of Biorheological Science and Technology, Chongqing University, Ministry of Education, Bioengineering College, Chongqing University, Chongqing 400030, China.
| |
Collapse
|
16
|
Affiliation(s)
- Daihyun Kim
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, United States
- Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| | - Mukul Sonker
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, United States
- Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| | - Alexandra Ros
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, United States
- Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| |
Collapse
|
17
|
Lapizco-Encinas BH. On the recent developments of insulator-based dielectrophoresis: A review. Electrophoresis 2018; 40:358-375. [PMID: 30112789 DOI: 10.1002/elps.201800285] [Citation(s) in RCA: 84] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Revised: 08/06/2018] [Accepted: 08/08/2018] [Indexed: 01/26/2023]
Abstract
Insulator-based dielectrophoresis (iDEP), also known as electrodeless DEP, has become a well-known dielectrophoretic technique, no longer viewed as a new methodology. Significant advances on iDEP have been reported during the last 15 years. This review article aims to summarize some of the most important findings on iDEP organized by the type of dielectrophoretic mode: streaming and trapping iDEP. The former is primarily used for particle sorting, while the latter has great capability for particle enrichment. The characteristics of a wide array of devices are discussed for each type of dielectrophoretic mode in order to present an overview of the distinct designs and applications developed with iDEP. A short section on Joule heating effects and electrothermal flow is also included to highlight some of the challenges in the utilization of iDEP systems. The significant progress on iDEP illustrates its potential for a large number of applications, ranging from bioanalysis to clinical and biomedical assessments. The present article discusses the work on iDEP by numerous research groups around the world, with the aim of proving the reader with an overview of the state-of-the-art in iDEP microfluidic systems.
Collapse
|
18
|
Abstract
The ability to separate analytes with increasingly similar properties drives the field of separation science. One way to achieve such separations is using trapping and streaming dielectrophoresis (DEP), which directly exploits the subtle differences in the electrophysical properties of analytes. The non-uniform fields necessary for DEP can be formed using various insulator shapes in microchannels. Current insulator shapes include triangles, diamonds, circles, and rectangles. However, all of these insulators pose problems for trapping, streaming, and sorting (deflection) as the induced fields/gradients are not behaviorally consistent across the lateral dimension. This leads to analytes experiencing different forces depending on their pathline in the microchannel and result in low resolution separations. Based on an iterative process that explored approximately 40 different insulator shapes, a design was chosen that indicated improved particle streamlines, better trapping efficiency, and consistent electrical environments across the lateral dimension. The design was assessed by simulations where the electric field, gradient of the electric field squared, and the ratio of the two were plotted. The improved design includes a unique new multi-length scale element. The multi-length scale structure streamlines the analyte(s) and improves homogeneity in the lateral dimension, while still achieving high gradients necessary for analyte separation using DEP. The design is calculated to keep analytes on the centerline which should improve resolution, and eliminate extraneous trapping zones. Behaviors consistent with the features of the simulations were observed in proof of principle experiments using representative test probes.
Collapse
Affiliation(s)
- Claire V Crowther
- Arizona State University, School of Molecular Sciences, Mail Stop 1604, Tempe, AZ 85287, USA.
| | | |
Collapse
|
19
|
Salafi T, Zeming KK, Zhang Y. Advancements in microfluidics for nanoparticle separation. LAB ON A CHIP 2016; 17:11-33. [PMID: 27830852 DOI: 10.1039/c6lc01045h] [Citation(s) in RCA: 128] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Nanoparticles have been widely implemented for healthcare and nanoscience industrial applications. Thus, efficient and effective nanoparticle separation methods are essential for advancement in these fields. However, current technologies for separation, such as ultracentrifugation, electrophoresis, filtration, chromatography, and selective precipitation, are not continuous and require multiple preparation steps and a minimum sample volume. Microfluidics has offered a relatively simple, low-cost, and continuous particle separation approach, and has been well-established for micron-sized particle sorting. Here, we review the recent advances in nanoparticle separation using microfluidic devices, focusing on its techniques, its advantages over conventional methods, and its potential applications, as well as foreseeable challenges in the separation of synthetic nanoparticles and biological molecules, especially DNA, proteins, viruses, and exosomes.
Collapse
Affiliation(s)
- Thoriq Salafi
- NUS Graduate School for Integrative Sciences and Engineering, Centre for Life Sciences (CeLS), National University of Singapore, 05-01 28 Medical Drive, 117456 Singapore. and Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, Block EA #03-12, 117576 Singapore
| | - Kerwin Kwek Zeming
- Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, Block EA #03-12, 117576 Singapore
| | - Yong Zhang
- NUS Graduate School for Integrative Sciences and Engineering, Centre for Life Sciences (CeLS), National University of Singapore, 05-01 28 Medical Drive, 117456 Singapore. and Department of Biomedical Engineering, National University of Singapore, 9 Engineering Drive 1, Block EA #03-12, 117576 Singapore
| |
Collapse
|
20
|
Li D, Lu X, Song Y, Wang J, Li D, Xuan X. Sheathless electrokinetic particle separation in a bifurcating microchannel. BIOMICROFLUIDICS 2016; 10:054104. [PMID: 27703590 PMCID: PMC5035298 DOI: 10.1063/1.4962875] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Accepted: 09/04/2016] [Indexed: 05/11/2023]
Abstract
Particle separation has found practical applications in many areas from industry to academia. Current electrokinetic particle separation techniques primarily rely on dielectrophoresis, where the electric field gradients are generated by either active microelectrodes or inert micro-insulators. We develop herein a new type of electrokinetic method to continuously separate particles in a bifurcating microchannel. This sheath-free separation makes use of the inherent wall-induced electrical lift to focus particles towards the centerline of the main-branch and then deflect them to size-dependent flow paths in each side-branch. A theoretical model is also developed to understand such a size-based separation, which simulates the experimental observations with a good agreement. This electric field-driven sheathless separation can potentially be operated in a parallel or cascade mode to increase the particle throughput or resolution.
Collapse
Affiliation(s)
- Di Li
- Department of Mechanical Engineering, Clemson University , Clemson, South Carolina 29634-0921, USA
| | - Xinyu Lu
- Department of Mechanical Engineering, Clemson University , Clemson, South Carolina 29634-0921, USA
| | - Yongxin Song
- College of Marine Engineering, Dalian Maritime University , Dalian 116026, China
| | - Junsheng Wang
- College of Information Science and Technology, Dalian Maritime University , Dalian 116026, China
| | - Dongqing Li
- Department of Mechanical and Mechatronics Engineering, University of Waterloo , Waterloo, Ontario N2L 3G1, Canada
| | - Xiangchun Xuan
- Department of Mechanical Engineering, Clemson University , Clemson, South Carolina 29634-0921, USA
| |
Collapse
|
21
|
Hakoda M. Development of dielectrophoresis separator with an insulating porous membrane using DC-Offset AC Electric Fields. Biotechnol Prog 2016; 32:1292-1300. [DOI: 10.1002/btpr.2330] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Revised: 05/12/2016] [Indexed: 01/08/2023]
Affiliation(s)
- Masaru Hakoda
- Div. of Environmental Engineering Science; Faculty of Science and Technology, Gunma University; Japan
| |
Collapse
|
22
|
Adekanmbi EO, Srivastava SK. Dielectrophoretic applications for disease diagnostics using lab-on-a-chip platforms. LAB ON A CHIP 2016; 16:2148-67. [PMID: 27191245 DOI: 10.1039/c6lc00355a] [Citation(s) in RCA: 69] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Dielectrophoresis is a powerful technique used to distinguish distinct cellular identities in heterogeneous cell populations and to monitor changes in the cell state without the need for biochemical tags, including live and dead cells. Recent studies in the past decade have indicated that dielectrophoresis can be used to discriminate the disease state of cells by exploring the differences in the dielectric polarizabilities of the cells. Factors controlling the dielectric polarizability are dependent on the conductivity and permittivity of the cell and the suspending medium, the cell morphology, the internal structure, and the electric double layer effects associated with the charges on the cell surface. Diseased cells, such as those associated with malaria, cancer, dengue, anthrax and human African trypanosomiasis, could be spatially trapped by positive dielectrophoresis or spatially separated from other healthy cells by negative dielectrophoretic forces. The aim of this review was to provide a better and deeper understanding on how dielectrophoresis can be utilized to manipulate diseased cells. This review compiles and compares the significant findings obtained by researchers in manipulating abnormal or unhealthy cells.
Collapse
Affiliation(s)
- Ezekiel O Adekanmbi
- Department of Chemical and Material Engineering, University of Idaho, Moscow, 83844-1021, Idaho, USA.
| | | |
Collapse
|
23
|
A new approach to design an efficient micropost array for enhanced direct-current insulator-based dielectrophoretic trapping. Anal Bioanal Chem 2016; 408:5285-94. [DOI: 10.1007/s00216-016-9629-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Revised: 04/28/2016] [Accepted: 05/10/2016] [Indexed: 10/21/2022]
|
24
|
Adekanmbi EO, Ueti MW, Rinaldi B, Suarez CE, Srivastava SK. Insulator-based dielectrophoretic diagnostic tool for babesiosis. BIOMICROFLUIDICS 2016; 10:033108. [PMID: 27375817 PMCID: PMC4912563 DOI: 10.1063/1.4954196] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Accepted: 06/06/2016] [Indexed: 05/12/2023]
Abstract
Babesia species are obligate intraerythrocytic tick-borne protozoan parasites that are the etiologic agents of babesiosis, a potentially life-threatening, malaria-like illness in humans and animals. Babesia-infected people have been known to suffer from complications including liver problems, severe hemolytic anemia, and kidney failure. As reported by the Food and Drug Administration, 38% of mortality cases observed in transfusion recipients were associated with transfusion transmitted diseases of which babesiosis is the chief culprit. As of now, no tests have been licensed yet for screening blood donors for babesiosis. Current diagnostic tools for babesiosis including enzyme-linked immunosorbent assay, fluorescence in situ hybridization, and polymerase chain reaction are expensive and burdened with multifarious shortcomings. In this research, a low-cost, high-specificity, quick, and easy-to-use insulator-based dielectrophoretic diagnostic tool is developed for characterizing and concentrating Babesia-infected cells in their homogenous mixture with healthy cell population. In this work, a mixture of Babesia-infected (varying parasitemia) and healthy red blood cells (RBCs or erythrocytes) was exposed to non-uniform electric fields in a fabricated microfluidic platform to manipulate and sort the Babesia-infected cells within a minute. At DC voltage configurations of 10 V and 0/6 V in the inlet and the two outlet channels, respectively, the diseased cells were seen to flow in a direction different from the healthy RBCs. Bright field and fluorescence microscopy were utilized to present qualitative differentiation of the healthy erythrocytes from the infected cells. The proposed micro device platform was able to enrich RBCs from 0.1% to ∼70% parasitemia. This device, when finally developed into a point-of-care diagnostic chip, would enhance the detection of Babesia-infected erythrocytes and as well serve as a precursor to babesiosis vaccine development.
Collapse
Affiliation(s)
- Ezekiel O Adekanmbi
- Department of Chemical and Materials Engineering, University of Idaho , Moscow, Idaho 83844-1021, USA
| | - Massaro W Ueti
- Animal Disease Research Unit, Agricultural Research Service, U.S. Department of Agriculture , Pullman, Washington 99164-7030, USA
| | - Brady Rinaldi
- Department of Chemical and Materials Engineering, University of Idaho , Moscow, Idaho 83844-1021, USA
| | - Carlos E Suarez
- Animal Disease Research Unit, Agricultural Research Service, U.S. Department of Agriculture , Pullman, Washington 99164-7030, USA
| | - Soumya K Srivastava
- Department of Chemical and Materials Engineering, University of Idaho , Moscow, Idaho 83844-1021, USA
| |
Collapse
|
25
|
Saucedo-Espinosa MA, Rauch MM, LaLonde A, Lapizco-Encinas BH. Polarization behavior of polystyrene particles under direct current and low-frequency (<1 kHz) electric fields in dielectrophoretic systems. Electrophoresis 2015; 37:635-44. [PMID: 26531799 DOI: 10.1002/elps.201500338] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Revised: 09/26/2015] [Accepted: 10/22/2015] [Indexed: 11/11/2022]
Abstract
The relative polarization behavior of micron and submicron polystyrene particles was investigated under direct current and very low frequency (<1 kHz) alternating current electric fields. Relative polarization of particles with respect to the suspending medium is expressed in terms of the Clausius-Mossotti factor, a parameter of crucial importance in dielectrophoretic-based operations. Particle relative polarization was studied by employing insulator-based dielectrophoretic (iDEP) devices. The effects of particle size, medium conductivity, and frequency (10-1000 Hz) of the applied electric potential on particle response were assessed through experiments and mathematical modeling with COMSOL Multiphysics(®). Particles of different sizes (100-1000 nm diameters) were introduced into iDEP devices fabricated from polydimethylsiloxane (PDMS) and their dielectrophoretic responses under direct and alternating current electric fields were recorded and analyzed in the form of images and videos. The results illustrated that particle polarizability and dielectrophoretic response depend greatly on particle size and the frequency of the electric field. Small particles tend to exhibit positive DEP at higher frequencies (200-1000 Hz), while large particles exhibit negative DEP at lower frequencies (20-200 Hz). These differences in relative polarization can be used for the design of iDEP-based separations and analysis of particle mixtures.
Collapse
Affiliation(s)
| | - Mallory M Rauch
- Microscale Bioseparations Laboratory, Rochester Institute of Technology, Rochester, NY, USA
| | - Alexandra LaLonde
- Microscale Bioseparations Laboratory, Rochester Institute of Technology, Rochester, NY, USA
| | | |
Collapse
|
26
|
Wang Y, Du F, Baune M, Thöming J. Predicting and eliminating Joule heating constraints in large dielectrophoretic IDE separators. Chem Eng Sci 2015. [DOI: 10.1016/j.ces.2015.06.042] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
27
|
Abdallah BG, Zatsepin NA, Roy-Chowdhury S, Coe J, Conrad CE, Dörner K, Sierra RG, Stevenson HP, Camacho-Alanis F, Grant TD, Nelson G, James D, Calero G, Wachter RM, Spence JCH, Weierstall U, Fromme P, Ros A. Microfluidic sorting of protein nanocrystals by size for X-ray free-electron laser diffraction. STRUCTURAL DYNAMICS (MELVILLE, N.Y.) 2015; 2:041719. [PMID: 26798818 PMCID: PMC4711642 DOI: 10.1063/1.4928688] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2015] [Accepted: 08/05/2015] [Indexed: 05/23/2023]
Abstract
The advent and application of the X-ray free-electron laser (XFEL) has uncovered the structures of proteins that could not previously be solved using traditional crystallography. While this new technology is powerful, optimization of the process is still needed to improve data quality and analysis efficiency. One area is sample heterogeneity, where variations in crystal size (among other factors) lead to the requirement of large data sets (and thus 10-100 mg of protein) for determining accurate structure factors. To decrease sample dispersity, we developed a high-throughput microfluidic sorter operating on the principle of dielectrophoresis, whereby polydisperse particles can be transported into various fluid streams for size fractionation. Using this microsorter, we isolated several milliliters of photosystem I nanocrystal fractions ranging from 200 to 600 nm in size as characterized by dynamic light scattering, nanoparticle tracking, and electron microscopy. Sorted nanocrystals were delivered in a liquid jet via the gas dynamic virtual nozzle into the path of the XFEL at the Linac Coherent Light Source. We obtained diffraction to ∼4 Å resolution, indicating that the small crystals were not damaged by the sorting process. We also observed the shape transforms of photosystem I nanocrystals, demonstrating that our device can optimize data collection for the shape transform-based phasing method. Using simulations, we show that narrow crystal size distributions can significantly improve merged data quality in serial crystallography. From this proof-of-concept work, we expect that the automated size-sorting of protein crystals will become an important step for sample production by reducing the amount of protein needed for a high quality final structure and the development of novel phasing methods that exploit inter-Bragg reflection intensities or use variations in beam intensity for radiation damage-induced phasing. This method will also permit an analysis of the dependence of crystal quality on crystal size.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Raymond G Sierra
- Stanford PULSE Institute, SLAC National Accelerator Laboratory , Menlo Park, California 94025, USA
| | - Hilary P Stevenson
- Department of Structural Biology, University of Pittsburgh School of Medicine , Pittsburgh, Pennsylvania 15261, USA
| | - Fernanda Camacho-Alanis
- Department of Chemistry and Biochemistry, Arizona State University , Tempe, Arizona 85287, USA
| | - Thomas D Grant
- Hauptman-Woodward Medical Research Institute, University at Buffalo , Buffalo, New York 14203, USA
| | | | | | - Guillermo Calero
- Department of Structural Biology, University of Pittsburgh School of Medicine , Pittsburgh, Pennsylvania 15261, USA
| | - Rebekka M Wachter
- Department of Chemistry and Biochemistry, Arizona State University , Tempe, Arizona 85287, USA
| | | | | | | | | |
Collapse
|
28
|
Jones PV, Hayes MA. Development of the resolution theory for gradient insulator-based dielectrophoresis. Electrophoresis 2015; 36:1098-106. [PMID: 25781578 DOI: 10.1002/elps.201400504] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2014] [Revised: 02/13/2015] [Accepted: 02/15/2015] [Indexed: 11/08/2022]
Abstract
New and important separations capabilities are being enabled by utilizing other electric field-induced forces besides electrophoresis, among these is dielectrophoresis. Recent works have used experimentally simple insulator-based systems that induce field gradients creating dielectrophoretic force in useful formats. Among these, juxtaposing forces can generate gradient-based steady-state separations schemes globally similar to isoelectric focusing. The system of interest is termed gradient insulator-based dielectrophoresis and can create extremely high resolution steady-state separations for particles four nanometers to ten micrometers in diameter, including nearly all important bioparticles (large proteins, protein aggregates, polynucleotides viruses, organelles, cells, bacteria, etc.). A theoretical underpinning is developed here to understand the relationship between experimental parameters and resolution and to identify the best expected resolution possible. According to the results, differences in particles (and bioparticles) as small as one part in 10(4) for diameter (subnanometer resolution for a one micrometer particle), one part in 10(8) for dielectrophoretic parameters (dielectrophoretic mobility, Clausius-Mossotti factor), and one part in 10(5) for electrophoretic mobility can be resolved. These figures of merit are generally better than any competing technique, in some cases by orders of magnitude. This performance is enabled by very strong focusing forces associated with localized gradients.
Collapse
Affiliation(s)
- Paul V Jones
- Department of Chemistry and Biochemistry, Arizona State University, AZ, USA
| | - Mark A Hayes
- Department of Chemistry and Biochemistry, Arizona State University, AZ, USA
| |
Collapse
|
29
|
Mohammadi M, Madadi H, Casals-Terré J, Sellarès J. Hydrodynamic and direct-current insulator-based dielectrophoresis (H-DC-iDEP) microfluidic blood plasma separation. Anal Bioanal Chem 2015; 407:4733-44. [DOI: 10.1007/s00216-015-8678-2] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Revised: 02/23/2015] [Accepted: 04/02/2015] [Indexed: 11/28/2022]
|
30
|
Abdallah BG, Roy-Chowdhury S, Coe J, Fromme P, Ros A. High throughput protein nanocrystal fractionation in a microfluidic sorter. Anal Chem 2015; 87:4159-67. [PMID: 25794348 DOI: 10.1021/acs.analchem.5b00589] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Protein crystallography is transitioning into a new generation with the introduction of the X-ray free electron laser, which can be used to solve the structures of complex proteins via serial femtosecond crystallography. Sample characteristics play a critical role in successful implementation of this new technology, whereby a small, narrow protein crystal size distribution is desired to provide high quality diffraction data. To provide such a sample, we developed a microfluidic device that facilitates dielectrophoretic sorting of heterogeneous particle mixtures into various size fractions. The first generation device demonstrated great potential and success toward this endeavor; thus, in this work, we present a comprehensive optimization study to improve throughput and control over sorting outcomes. First, device geometry was designed considering a variety of criteria, and applied potentials were modeled to determine the scheme achieving the largest sorting efficiency for isolating nanoparticles from microparticles. Further, to investigate sorting efficiency within the nanoparticle regime, critical geometrical dimensions and input parameters were optimized to achieve high sorting efficiencies. Experiments revealed fractionation of nanobeads from microbeads in the optimized device with high sorting efficiencies, and protein crystals were sorted into submicrometer size fractions as desired for future serial femtosecond crystallography experiments.
Collapse
Affiliation(s)
- Bahige G Abdallah
- Department of Chemistry and Biochemistry, Arizona State University, Tempe, Arizona 85287, United States.,Center for Applied Structural Discovery, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| | - Shatabdi Roy-Chowdhury
- Department of Chemistry and Biochemistry, Arizona State University, Tempe, Arizona 85287, United States.,Center for Applied Structural Discovery, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| | - Jesse Coe
- Department of Chemistry and Biochemistry, Arizona State University, Tempe, Arizona 85287, United States.,Center for Applied Structural Discovery, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| | - Petra Fromme
- Department of Chemistry and Biochemistry, Arizona State University, Tempe, Arizona 85287, United States.,Center for Applied Structural Discovery, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| | - Alexandra Ros
- Department of Chemistry and Biochemistry, Arizona State University, Tempe, Arizona 85287, United States.,Center for Applied Structural Discovery, Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| |
Collapse
|
31
|
Cheri MS, Latifi H, Khashei H, Seresht MJ. Focusing and continuous separation of microparticles by insulator-based dielectrophoresis (iDEP) in stair-shaped microchannel. Electrophoresis 2014; 35:3523-32. [PMID: 25256784 DOI: 10.1002/elps.201400349] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2014] [Revised: 08/31/2014] [Accepted: 09/03/2014] [Indexed: 11/08/2022]
Abstract
Focusing and separation of microparticles in a complex mixture have had wide applications in chemistry, biology, medicine, etc. This work presents a numerical and experimental investigation on focusing and continuous separation of microparticles in a geometrically optimized arrangement of steps in the form of a staircase using insulator-based dielectrophoresis (iDEP) mechanism. First, a detailed finite element analysis was performed on important parameters in the focusing and separation of microparticles, such as geometry of stair-shaped microchannel, total voltage, and voltage difference applied to reservoirs. The optimum parameters obtained from numerical analysis were used for experimental work. Theoretically, predicted microparticle trajectories are in good agreement with experimentally observed ones. Experimental and numerical results show that the performance of focusing of microparticles enhances with growth of the total voltage (in a constant voltage difference) and decreases with voltage difference. The fabricated iDEP microchip enhances the performance of focusing and separation of microparticles due to its stair-shaped microchannel and therefore operates at low DC total applied voltages of 90-110 V.
Collapse
Affiliation(s)
- Mohammad Sadegh Cheri
- Laser and Plasma Institute, Shahid Beheshti University, Tehran, Iran; Department of Physics, Shahid Beheshti University, Tehran, Iran
| | | | | | | |
Collapse
|
32
|
Song Y, Li M, Pan X, Wang Q, Li D. Size-based cell sorting with a resistive pulse sensor and an electromagnetic pump in a microfluidic chip. Electrophoresis 2014; 36:398-404. [DOI: 10.1002/elps.201400292] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2014] [Revised: 08/03/2014] [Accepted: 08/11/2014] [Indexed: 12/24/2022]
Affiliation(s)
- Yongxin Song
- Department of Marine Engineering; Dalian Maritime University; Dalian P. R. China
| | - Mengqi Li
- Department of Marine Engineering; Dalian Maritime University; Dalian P. R. China
| | - Xinxiang Pan
- Department of Marine Engineering; Dalian Maritime University; Dalian P. R. China
| | - Qi Wang
- Department of Respiratory Medicine; The second affiliated hospital of Dalian Medical University; Dalian P. R. China
| | - Dongqing Li
- Department of Mechanical and Mechatronics Engineering; University of Waterloo; Waterloo Ontario Canada
| |
Collapse
|
33
|
Gwon HR, Chang ST, Choi CK, Jung JY, Kim JM, Lee SH. Development of a new contactless dielectrophoresis system for active particle manipulation using movable liquid electrodes. Electrophoresis 2014; 35:2014-21. [PMID: 24737601 DOI: 10.1002/elps.201300566] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2013] [Revised: 04/01/2014] [Accepted: 04/03/2014] [Indexed: 11/07/2022]
Abstract
This study presents a new DEP manipulation technique using a movable liquid electrode, which allows manipulation of particles by actively controlling the locations of electrodes and applying on-off electric input signals. This DEP system consists of mercury as a movable liquid electrode, indium tin oxide (ITO)-coated glass, SU-8-based microchannels for electrode passages, and a PDMS medium chamber. A simple squeezing method was introduced to build a thin PDMS layer at the bottom of the medium chamber to create a contactless DEP system. To determine the operating conditions, the DEP force and the friction force were analytically compared for a single cell. In addition, an appropriate frequency range for effective DEP manipulation was chosen based on an estimation of the Clausius-Mossotti factor and the effective complex permittivity of the yeast cell using the concentric shell model. With this system, we demonstrated the active manipulation of yeast cells, and measured the collection efficiency and the dielectrophoretic velocity of cells for different AC electric field strengths and applied frequencies. The experimental results showed that the maximum collection efficiency reached was approximately 90%, and the dielectrophoretic velocity increased with increasing frequency and attained the maximum value of 10.85 ± 0.95 μm/s at 100 kHz, above which it decreased.
Collapse
Affiliation(s)
- Hyuk Rok Gwon
- School of Mechanical Engineering, Chung-Ang University, Heuksuk-dong, Dongjak-gu, Seoul, Korea
| | | | | | | | | | | |
Collapse
|
34
|
LaLonde A, Gencoglu A, Romero-Creel MF, Koppula KS, Lapizco-Encinas BH. Effect of insulating posts geometry on particle manipulation in insulator based dielectrophoretic devices. J Chromatogr A 2014; 1344:99-108. [DOI: 10.1016/j.chroma.2014.03.083] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2013] [Revised: 03/25/2014] [Accepted: 03/30/2014] [Indexed: 10/25/2022]
|
35
|
Jubery TZ, Srivastava SK, Dutta P. Dielectrophoretic separation of bioparticles in microdevices: A review. Electrophoresis 2014; 35:691-713. [DOI: 10.1002/elps.201300424] [Citation(s) in RCA: 169] [Impact Index Per Article: 16.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2013] [Revised: 12/04/2013] [Accepted: 12/09/2013] [Indexed: 12/11/2022]
Affiliation(s)
- Talukder Z. Jubery
- School of Mechanical and Materials Engineering; Washington State University; Pullman WA USA
| | - Soumya K. Srivastava
- Department of Chemical and Materials Engineering; University of Idaho; Moscow ID USA
| | - Prashanta Dutta
- School of Mechanical and Materials Engineering; Washington State University; Pullman WA USA
| |
Collapse
|
36
|
Lewpiriyawong N, Yang C. Continuous separation of multiple particles by negative and positive dielectrophoresis in a modified H-filter. Electrophoresis 2014; 35:714-20. [DOI: 10.1002/elps.201300429] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2013] [Revised: 11/18/2013] [Accepted: 11/30/2013] [Indexed: 11/10/2022]
Affiliation(s)
- Nuttawut Lewpiriyawong
- Department of Mechanical Engineering; King Mongkut's Institute of Technology Ladkrabang; Bangkok Thailand
| | - Chun Yang
- School of Mechanical and Aerospace Engineering; Nanyang Technological University; Singapore
| |
Collapse
|
37
|
Gencoglu A, Olney D, LaLonde A, Koppula KS, Lapizco-Encinas BH. Dynamic microparticle manipulation with an electroosmotic flow gradient in low-frequency alternating current dielectrophoresis. Electrophoresis 2013; 35:362-73. [PMID: 24166858 DOI: 10.1002/elps.201300385] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2013] [Revised: 10/07/2013] [Accepted: 10/16/2013] [Indexed: 11/07/2022]
Abstract
In this study, the potential of low-frequency AC insulator-based DEP (iDEP) was explored for the separation of polystyrene microparticles and yeast cells. An EOF gradient was generated by employing an asymmetrical, 20 Hz AC electrical signal in an iDEP device consisting of a microchannel with diamond-shaped insulating posts. Two types of samples were analyzed, the first sample contained three types of polystyrene particles with different diameters (0.5, 1.0, and 2.0 μm) and the second sample contained two types of polystyrene particles (1.0 and 2 μm) and yeast cells (6.3 μm). This particular scheme uses a tapered AC signal that allows for all particles to be trapped and concentrated at the insulating post array, as the signal becomes asymmetrical (more positive), particles are selectively released. The smallest particles in each sample were released first, since they require greater dielectrophoretic forces to remain trapped. The largest particles in each sample were released last, when the applied signal became cyclical. A dielectropherogram, which is analogous to a chromatogram, was obtained for each sample, demonstrating successful separation of the particles by showing "peaks" of the released particles. These separations were achieved at lower applied potentials than those reported in previous studies that used solely direct current electrical voltages. Additionally, mathematical modeling with COMSOL Multiphysics was carried out to estimate the magnitude of the dielectrophoretic and EOF forces acting on the particles considering the low-frequency, asymmetrical AC signal used in the experiments. The results demonstrated the potential of low-frequency AC-iDEP systems for handling and separating complex mixtures of microparticles and biological cells.
Collapse
Affiliation(s)
- Aytug Gencoglu
- Microscale Bioseparations Laboratory, Department of Chemical and Biomedical Engineering, Rochester Institute of Technology, Rochester, NY, USA
| | | | | | | | | |
Collapse
|
38
|
Abdallah BG, Chao TC, Kupitz C, Fromme P, Ros A. Dielectrophoretic sorting of membrane protein nanocrystals. ACS NANO 2013; 7:9129-37. [PMID: 24004002 PMCID: PMC3894612 DOI: 10.1021/nn403760q] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Structure elucidation of large membrane protein complexes is still a considerable challenge, yet is a key factor in drug development and disease combat. Femtosecond nanocrystallography is an emerging technique with which structural information of membrane proteins is obtained without the need to grow large crystals, thus overcoming the experimental riddle faced in traditional crystallography methods. Here, we demonstrate for the first time a microfluidic device capable of sorting membrane protein crystals based on size using dielectrophoresis. We demonstrate the excellent sorting power of this new approach with numerical simulations of selected submicrometer beads in excellent agreement with experimental observations. Crystals from batch crystallization broths of the huge membrane protein complex photosystem I were sorted without further treatment, resulting in a high degree of monodispersity and crystallinity in the ~100 nm size range. Microfluidic integration, continuous sorting, and nanometer-sized crystal fractions make this method ideal for direct coupling to femtosecond nanocrystallography.
Collapse
Affiliation(s)
| | - Tzu-Chiao Chao
- Department of Biology, University of Regina, Regina, SK, S4S0A2, Canada
| | | | | | | |
Collapse
|
39
|
Gencoglu A, Olney D, LaLonde A, Koppula KS, Lapizco-Encinas BH. Particle Manipulation in Insulator Based Dielectrophoretic Devices1. J Nanotechnol Eng Med 2013. [DOI: 10.1115/1.4025368] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Microfluidic devices can make a significant impact in many fields where obtaining a rapid response is critical, particularly in analyses involving biological particles, from deoxyribonucleic acid (DNA) and proteins, to cells. Microfluidics has revolutionized the manner in which many different assessments/processes are carried out, since it offers attractive advantages over traditional bench-scale techniques. Some of the advantages are: small sample and reagent amounts, higher resolution and sensitivity, improved level of integration and automation, lower cost and much shorter processing times. There is a growing interest on the development of techniques that can be used in microfluidics devices. Among these, electrokinetic techniques have shown great potential due to their flexibility. Dielectrophoresis (DEP) is an electrokinetic mechanism that refers to the interaction of a dielectric particle with a spatially non-uniform electric field; this leads to particle movement due to polarization effects. DEP offers great potential since it can be carried out employing DC and AC electric fields, and neutral and charged particles can be manipulated. This work is focused on the use of insulator based dielectrophoresis (iDEP), a novel dielectrophoretic mode that employs arrays of insulating structures to generate dielectrophoretic forces. Successful micro and nanoparticles manipulation can be achieved employing iDEP, due to its unique characteristics that allow for great flexibility. In this work, microchannels containing arrays of cylindrical insulating posts were employed to concentrate, sort and separate microparticles. Mathematical modeling with COMSOL® was performed to identify optimal device configuration. Different sets of experiments were carried out employing DC and AC potentials. The results demonstrated that effective and fast particle manipulation is possible by fine tuning dielectrophoretic force and electroosmotic flow.
Collapse
Affiliation(s)
| | | | | | | | - Blanca H. Lapizco-Encinas
- Associate Professor e-mail: Microscale Bioseparations Laboratory, Chemical and Biomedical Engineering Department, Rochester Institute of Technology, Rochester, NY 14623
| |
Collapse
|
40
|
Ivory CF, Srivastava SK. Direct current dielectrophoretic simulation of proteins using an array of circular insulating posts. Electrophoresis 2013; 32:2323-30. [PMID: 23361922 DOI: 10.1002/elps.201100115] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2011] [Revised: 06/02/2011] [Accepted: 06/06/2011] [Indexed: 11/07/2022]
Abstract
This paper presents a mathematical model for the manipulation of proteins using insulator-based dielectrophoresis (iDEP) and direct current (DC) electric fields. Simulations via COMSOL v4.1 Multiphysics software are implemented to study the response of moderately sized proteins on a lab-on-a-chip platform. The geometry of the device is incorporated in a model that solves current and mass conservation equations within an array of circular insulating silicon posts embedded in a channel. Both micro- and nano-scale geometries are utilized to investigate the protein concentration distributions in the iDEP device. Our results indicate that the trapping of proteins is independent of the scale with respect to the geometry of a device as long as the applied electric field remains constant. DC voltage dependency on concentration distributions has also been explored in both micro- and nano-scale device geometries. To achieve DEP trapping of the proteins, nano-scale geometry is a better selection, as the voltage necessary to generate the required electric field (2.5 MV/cm) is 10(5) × lower compared with the voltage required to generate the same field in the micro-scale device.
Collapse
Affiliation(s)
- Cornelius F Ivory
- Voiland School of Chemical Engineering and Bioengineering, Washington State University, WA 99l64-27l0, USA
| | | |
Collapse
|
41
|
Song Y, Peng R, Wang J, Pan X, Sun Y, Li D. Automatic particle detection and sorting in an electrokinetic microfluidic chip. Electrophoresis 2013; 34:684-90. [DOI: 10.1002/elps.201200416] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2012] [Revised: 09/29/2012] [Accepted: 10/18/2012] [Indexed: 01/09/2023]
Affiliation(s)
- Yongxin Song
- Department of Marine Engineering; Dalian Maritime University; Dalian; P. R. China
| | - Ran Peng
- Department of Marine Engineering; Dalian Maritime University; Dalian; P. R. China
| | - Junsheng Wang
- College of Information Science and Technology; Dalian Maritime University; Dalian; P. R. China
| | - Xinxiang Pan
- Department of Marine Engineering; Dalian Maritime University; Dalian; P. R. China
| | - Yeqing Sun
- Institute of Environmental Systems Biology; Dalian Maritime University; Dalian; P. R. China
| | - Dongqing Li
- Department of Mechanical and Mechatronics Engineering; University of Waterloo; Waterloo; ON; Canada
| |
Collapse
|
42
|
Nakano A, Camacho-Alanis F, Chao TC, Ros A. Tuning direct current streaming dielectrophoresis of proteins. BIOMICROFLUIDICS 2012; 6:34108. [PMID: 23908679 PMCID: PMC3423305 DOI: 10.1063/1.4742695] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2012] [Accepted: 07/18/2012] [Indexed: 05/03/2023]
Abstract
Dielectrophoresis (DEP) of biomolecules has large potential to serve as a novel selectivity parameter for bioanalytical methods such as (pre)concentration, fractionation, and separation. However, in contrast to well-characterized biological cells and (nano)particles, the mechanism of protein DEP is poorly understood, limiting bioanalytical applications for proteins. Here, we demonstrate a detailed investigation of factors influencing DEP of diagnostically relevant immunoglobulin G (IgG) molecules using insulator-based DEP (iDEP) under DC conditions. We found that the pH range in which concentration of IgG due to streaming iDEP occurs without aggregate formation matches the pH range suitable for immunoreactions. Numerical simulations of the electrokinetic factors pertaining to DEP streaming in this range further suggested that the protein charge and electroosmotic flow significantly influence iDEP streaming. These predictions are in accordance with the experimentally observed pH-dependent iDEP streaming profiles as well as the determined IgG molecular properties. Moreover, we observed a transition in the streaming behavior caused by a change from positive to negative DEP induced through micelle formation for the first time experimentally, which is in excellent qualitative agreement with numerical simulations. Our study thus relates molecular immunoglobulin properties to observed iDEP, which will be useful for the future development of protein (pre)concentration or separation methods based on DEP.
Collapse
Affiliation(s)
- Asuka Nakano
- Department of Chemistry and Biochemistry, Arizona State University, Tempe, Arizona 85287, USA
| | | | | | | |
Collapse
|
43
|
Cheng W, Li SZ, Zeng Q, Yu XL, Wang Y, Chan HLW, Liu W, Guo SS, Zhao XZ. Rapid microparticle patterning by enhanced dielectrophoresis effect on a double-layer electrode substrate. Electrophoresis 2011; 32:3371-7. [DOI: 10.1002/elps.201100232] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2011] [Revised: 06/09/2011] [Accepted: 06/24/2011] [Indexed: 11/09/2022]
|
44
|
Srivastava SK, Artemiou A, Minerick AR. Direct current insulator-based dielectrophoretic characterization of erythrocytes: ABO-Rh human blood typing. Electrophoresis 2011; 32:2530-40. [PMID: 21922495 DOI: 10.1002/elps.201100089] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2011] [Revised: 06/08/2011] [Accepted: 06/08/2011] [Indexed: 11/10/2022]
Abstract
A microfluidic platform developed for quantifying the dependence of erythrocyte (red blood cell, RBC) responses by ABO-Rh blood type via direct current insulator dielectrophoresis (DC-iDEP) is presented. The PDMS DC-iDEP device utilized a 400 x 170 μm² rectangular insulating obstacle embedded in a 1.46-cm long, 200-μm wide inlet channel to create spatial non-uniformities in direct current (DC) electric field density realized by separation into four outlet channels. The DC-iDEP flow behaviors were investigated for all eight blood types (A+, A-, B+, B-, AB+, AB-, O+, O-) in the human ABO-Rh blood typing system. Three independent donors of each blood type, same donor reproducibility, different conductivity buffers (0.52-9.1 mS/cm), and DC electric fields (17.1-68.5 V/cm) were tested to investigate separation dependencies. The data analysis was conducted from image intensity profiles across inlet and outlet channels in the device. Individual channel fractions suggest that the dielectrophoretic force experienced by the cells is dependent on erythrocyte antigen expression. Two different statistical analysis methods were conducted to determine how distinguishable a single blood type was from the others. Results indicate that channel fraction distributions differ by ABO-Rh blood types suggesting that antigens present on the erythrocyte membrane polarize differently in DC-iDEP fields. Under optimized conductivity and field conditions, certain blind blood samples could be sorted with low misclassification rates.
Collapse
Affiliation(s)
- Soumya K Srivastava
- Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA, USA
| | | | | |
Collapse
|
45
|
Regtmeier J, Eichhorn R, Viefhues M, Bogunovic L, Anselmetti D. Electrodeless dielectrophoresis for bioanalysis: Theory, devices and applications. Electrophoresis 2011; 32:2253-73. [DOI: 10.1002/elps.201100055] [Citation(s) in RCA: 101] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2011] [Revised: 05/31/2011] [Accepted: 06/01/2011] [Indexed: 01/05/2023]
|
46
|
Gallo-Villanueva RC, Pérez-González VH, Davalos RV, Lapizco-Encinas BH. Separation of mixtures of particles in a multipart microdevice employing insulator-based dielectrophoresis. Electrophoresis 2011; 32:2456-65. [PMID: 21874656 DOI: 10.1002/elps.201100174] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2011] [Revised: 05/27/2011] [Accepted: 05/31/2011] [Indexed: 11/09/2022]
Abstract
Dielectrophoresis is the electrokinetic movement of particles due to polarization effects in the presence of non-uniform electric fields. In insulator-based dielectrophoresis (iDEP) regions of low and high electric field intensity, i.e. non-uniformity of electric field, are produced when the cross-sectional area of a microchannel is decreased by the presence of electrical insulating structures between two electrodes. This technique is increasingly being studied for the manipulation of a wide variety of particles, and novel designs are continuously developed. Despite significant advances in the area, complex mixture separation and sample fractionation continue to be the most important challenges. In this work, a microchannel design is presented for carrying out direct current (DC)-iDEP for the separation of a mixture of particles. The device comprises a main channel, two side channels and two sections of cylindrical posts with different diameters, which will generate different non-uniformities in the electric field on the main channel, designed for the discrimination and separation of particles of two different sizes. By applying an electric potential of 1000 V, a mixture of 1 and 4 μm polystyrene microspheres were dielectrophoretically separated and concentrated at the same time and then redirected to different outlets. The results obtained here demonstrate that, by carefully designing the device geometry and selecting operating conditions, effective sorting of particle mixtures can be achieved in this type of multi-section DC-iDEP devices.
Collapse
|
47
|
Nakano A, Chao TC, Camacho-Alanis F, Ros A. Immunoglobulin G and bovine serum albumin streaming dielectrophoresis in a microfluidic device. Electrophoresis 2011; 32:2314-22. [PMID: 21792990 DOI: 10.1002/elps.201100037] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2011] [Revised: 03/31/2011] [Accepted: 04/13/2011] [Indexed: 11/09/2022]
Abstract
Dielectrophoresis (DEP) has demonstrated to be a versatile tool to manipulate micro- and nanoparticles with applications for positioning, separation and fractionation. Recent developments of DEP have also shown that DEP can be used for the manipulation of biomolecules, such as DNA. Here, we focus on the manipulation of proteins using insulator-based dielectrophoresis (iDEP). We designed suitable post arrays in a microfluidic channel and use numerical simulations to calculate the electric field distribution as well as concentration of proteins according to a convection-diffusion model for both negative and positive DEP. Experimentally, we find DEP trapping of mainly protein aggregates in phosphate buffer. However, when adding a charged zwitterionic detergent, we observed DEP streamlining of immunoglobulin G (IgG) and bovine serum albumin (BSA). Our experimental observations are in excellent agreement with numerical simulations and indicate positive DEP behavior of IgG and BSA under the employed experimental conditions. Our results demonstrate DEP streaming of proteins in an iDEP device for the first time and indicate the potential of protein DEP for separation and fractionation.
Collapse
Affiliation(s)
- Asuka Nakano
- Department of Chemistry and Biochemistry, Arizona State University, Tempe 85287-1604, USA
| | | | | | | |
Collapse
|
48
|
Zhu J, Xuan X. Curvature-induced dielectrophoresis for continuous separation of particles by charge in spiral microchannels. BIOMICROFLUIDICS 2011; 5:24111. [PMID: 21792385 PMCID: PMC3143671 DOI: 10.1063/1.3599883] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2011] [Accepted: 05/21/2011] [Indexed: 05/07/2023]
Abstract
The separation of particles from a heterogeneous mixture is critical in chemical and biological analyses. Many methods have been developed to separate particles in microfluidic devices. However, the majority of these separations have been limited to be size based and binary. We demonstrate herein a continuous dc electric field driven separation of carboxyl-coated and noncoated 10 μm polystyrene beads by charge in a double-spiral microchannel. This method exploits the inherent electric field gradients formed within the channel turns to manipulate particles by dielectrophoresis and is thus termed curvature-induced dielectrophoresis. The spiral microchannel is also demonstrated to continuously sort noncoated 5 μm beads, noncoated 10 μm beads, and carboxyl-coated 10 μm beads into different collecting wells by charge and size simultaneously. The observed particle separation processes in different situations are all predicted with reasonable agreements by a numerical model. This curvature-induced dielectrophoresis technique eliminates the in-channel microelectrodes and obstacles that are required in traditional electrode- and insulator-based dielectrophoresis devices. It may potentially be used to separate multiple particle targets by intrinsic properties for lab-on-a-chip applications.
Collapse
Affiliation(s)
- Junjie Zhu
- Department of Mechanical Engineering, Clemson University, Clemson, South Carolina 29634-0921, USA
| | | |
Collapse
|